SELECTION

How to select a submersible pumpset TMH in m.


In order to correctly select the pump The total manometric head is calcu­
and the materials to be used, it is lated on the basis of the following
necessary to consider of the following parameters:
fac­tors: - Dynamic water level in the well at the
Water characteristics : required pumping capacity Hd in m.
- Geodetic head above ground level Hg:
- Type of water (potable, salty, indu­
• Up to the highest water level in the
strial, thermal, etc.)
elevated tank in m.
- Sand contents in PPM [g/m³]
• Up to the highest level of the di­
- Temperature in °C
scharge pipeline in m.
- pH (acidity or alkanity value)
• Highest pressure in the pressure
Well type: tank or at the sprinklers in m.
- Type of well (bored, artesian, tank)
Characteristics of the pipeline:
- Depth in [m or ft].
- Total length - diameter
- Internal diameter at point where
- Type and maintenance state
pump will be installed.
- Number of elbows and val­ves
Use:
Power supply:
- Free discharge at ground level
- Single or three phases
- Discharge into an elevated tank
- Voltage value- Frequency
- Discharge into a pressure tank
- Voltage and frequency changes in
- Sprinkler irrigation
percent
- Other uses.
Control panel:
Capacity:
- Manual - automatic
- Q in m3/h - I/min - I/sec - USGPM
Starting system:
Total manometric head:
- Direct On/Line
(inclusive of all friction losses)
- Statoric im­pedance- Star/Delta,
- Auto-Transformer
- Soft Starting - Frequency converter

1 / Control panel
2 / Gate valve
3 / Pressure gauge
4 / Electric cable
5 / Riser pipe
6 / Electrode for low water level control
7 / Submersible pumpset
8 / Well
9 / Filter

A / Power supply
B / User

Hs: Static water level


Hd: Dynamic water level
Hg: Geodetic head