FOOTING DIMENSIONS

FOOTING NUMBER REINFORCEMENTS


L W T
F8 2700 2700 350

DATA AND SPECIFICATIONS


ULTIMATE CONCRETE STRENGTH, FC'
UNIT WEIGHT OF CONCRETE, W
ASSUMED UNIT WEIGHT OF SOIL
YIELD STRENGTH OF BARS, FY
BAR DIAMETER
ALLOWABLE SOIL PRESSURE, QA (ASSUMED)
ASSUME DEPTH OF FOOTING BASE FROM THE FINISH GROUND, DF
B, (IF FC' LESS THAN OR EQUAL TO 30 MPA)
COLUMN DIMENSIONS:
LONG SIDE, C
SHORT SIDE, L
RATIO, BC=C/L

DESIGN AND CALCULATIONS


A. SERVICE LOAD COMBINATION (LOAD COMBO SERIES 300)
AXIAL LOAD, PA 359.527 KN
BENDING MOMENT, MAY 0 KN.M
BENDING MOMENT, MAX 0 KN.M

B. COMBINATION (FACTORED)
AXIAL LOAD, PU 447.279 KN
BENDING MOMENT, MUY 0 KN.M
BENDING MOMENT, MUX 0 KN.M

C. FOOTING DESIGN
1. TRIAL DIMENSIONS
B 2.7 M
L 2.7 M
T 0.35 M

2. PROPORTIONING OF FOOTING
EFFECTIVE SOIL PRESSURE, QE 69.3596

3. CHECK ALLOWABLE SOIL PRESSURE ON EACH CORNER OF FOOTING


PA/BL 49.317832647 KPA
6MAX/BL2 0 KPA
6MAY/BL2 0 KPA
CORNER A, QA 49.317832647 KPA SAFE
CORNER B, QB 49.317832647 KPA SAFE
CORNERC, QC 49.317832647 KPA SAFE
CORNER D, QD 49.317832647 KPA SAFE

4. AVERAGE ULTIMATE SOIL PRESSURE


PU/BL 61.355144033 KPA
6MUX/BL2 0 KPA
6MUY/BL2 0 KPA
CORNER A, QA 61.355144033 KPA SAFE
CORNER B, QB 61.355144033 KPA SAFE
CORNERC, QC 61.355144033 KPA SAFE
CORNER D, QD 61.355144033 KPA SAFE
THEREFORE , USE 61.355144033 KPA

5. CHECK THCKNESS
A. BY BEAM SHEAR (ONE-WAY SHEAR)
EFFECTIVE DEPTH, D 265 MM
ALLOWABLE SHEAR STRENGTH, VA 270.50371505 KN
CRITICAL WIDTH FOR SHEAR STRESS,X 885 MM
ACTUAL SHEAR FORCE, VU 146.60811667 KN
THEREFORE, THE FOOTING IS SAFE FOR BEAM SHEA

B. PUNCHING SHEAR (TWO-WAY SHEAR)


BO 2660 MM
ALLOWABLE PUNCHIING FORCE, VP
VP 532.99250522 KN
VP 799.48875783 KN
THEREFORE, VPA 532.99250522 KN
ACTUAL PUNCHING SHEAR, VP 420.14622143 KN
THEREFORE, THE FOOTING IS SAFE FOR PUNCHING

6. STEEL REQUIREMENTS
A. ALONG LONG DIRECTION, L
CRITICAL WIDTH FOR MOMENT CAPACITY 1150
ULTIMATE MOMENT 109.541940278
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.03003546835
ACTUAL STEEL RATIO, 0.00228530737
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 3629.34782609
NUMBER OF BARS 11.5525729344
SAY 12
B. ALONG SHORT DIRECTION, B
CRITICAL WIDTH FOR MOMENT CAPACITY 1150
ULTIMATE MOMENT 109.541940278
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.03003546835
ACTUAL STEEL RATIO, 0.00228530737
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 3629.34782609
NUMBER OF BARS 11.5525729344
SAY 12
12 20 mm FOR SERVICE LOA
REINFORCEMENTS
12 20 mm NODE

2
21 MPA
23.544 KN/M3
16 KN/M3
276 MPA FOR ULTIMATE L
20 MM NODE
96 KPA
1.5 M
0.85

400 MM
400 MM 2
1

KPA

FOOTING
AFE FOR BEAM SHEAR

SAFE FOR PUNCHING

-3583581750 3710590526
0.03003546835 -1.724950723

20 mm bars
-3583581750 3710590526
0.03003546835 -1.724950723

20 mm bars
FOR SERVICE LOAD (UNFACTORED LOAD)
L/C FY MX MY
1 (EQX) 22.068 0 0
2 (EQZ) -28.79 0 0
3 (DL) 243.42 0 0
4 (LL) 94.039 0 0
5 (RLL) 9.426 0 0

FOR ULTIMATE LOAD (FACTORED LOAD)


L/C FY (PU) MX (MUX) MY (MUY)
6 340.788 0 0
7 447.279 0 0
8 354.205 0 0
9 361.191 0 0
10 317.055 0 0
11 310.333 0 0
12 367.913 0 0
13 197.01 0 0
14 241.146 0 0
15 247.868 0 0
16 190.288 0 0