FOOTING DIMENSIONS

FOOTING NUMBER REINFORCEMENTS


L W T
F9 2900 2900 400

DATA AND SPECIFICATIONS


ULTIMATE CONCRETE STRENGTH, FC'
UNIT WEIGHT OF CONCRETE, W
ASSUMED UNIT WEIGHT OF SOIL
YIELD STRENGTH OF BARS, FY
BAR DIAMETER
ALLOWABLE SOIL PRESSURE, QA (ASSUMED)
ASSUME DEPTH OF FOOTING BASE FROM THE FINISH GROUND, DF
B, (IF FC' LESS THAN OR EQUAL TO 30 MPA)
COLUMN DIMENSIONS:
LONG SIDE, C
SHORT SIDE, L
RATIO, BC=C/L

DESIGN AND CALCULATIONS


A. SERVICE LOAD COMBINATION (LOAD COMBO SERIES 300)
AXIAL LOAD, PA 435.958 KN
BENDING MOMENT, MAY 0 KN.M
BENDING MOMENT, MAX 0 KN.M

B. COMBINATION (FACTORED)
AXIAL LOAD, PU 570.875 KN
BENDING MOMENT, MUY 0 KN.M
BENDING MOMENT, MUX 0 KN.M

C. FOOTING DESIGN
1. TRIAL DIMENSIONS
B 2.9 M
L 2.9 M
T 0.4 M

2. PROPORTIONING OF FOOTING
EFFECTIVE SOIL PRESSURE, QE 68.9824

3. CHECK ALLOWABLE SOIL PRESSURE ON EACH CORNER OF FOOTING


PA/BL 51.838049941 KPA
6MAX/BL2 0 KPA
6MAY/BL2 0 KPA
CORNER A, QA 51.838049941 KPA SAFE
CORNER B, QB 51.838049941 KPA SAFE
CORNERC, QC 51.838049941 KPA SAFE
CORNER D, QD 51.838049941 KPA SAFE

4. AVERAGE ULTIMATE SOIL PRESSURE


PU/BL 67.880499405 KPA
6MUX/BL2 0 KPA
6MUY/BL2 0 KPA
CORNER A, QA 67.880499405 KPA SAFE
CORNER B, QB 67.880499405 KPA SAFE
CORNERC, QC 67.880499405 KPA SAFE
CORNER D, QD 67.880499405 KPA SAFE
THEREFORE , USE 67.880499405 KPA

5. CHECK THCKNESS
A. BY BEAM SHEAR (ONE-WAY SHEAR)
EFFECTIVE DEPTH, D 315 MM
ALLOWABLE SHEAR STRENGTH, VA 345.36008903 KN
CRITICAL WIDTH FOR SHEAR STRESS,X 935 MM
ACTUAL SHEAR FORCE, VU 184.05797414 KN
THEREFORE, THE FOOTING IS SAFE FOR BEAM SHEA

B. PUNCHING SHEAR (TWO-WAY SHEAR)


BO 2860 MM
ALLOWABLE PUNCHIING FORCE, VP
VP 681.19300319 KN
VP 1021.7895048 KN
THEREFORE, VPA 681.19300319 KN
ACTUAL PUNCHING SHEAR, VP 536.17279169 KN
THEREFORE, THE FOOTING IS SAFE FOR PUNCHING

6. STEEL REQUIREMENTS
A. ALONG LONG DIRECTION, L
CRITICAL WIDTH FOR MOMENT CAPACITY 1250
ULTIMATE MOMENT 153.791756466
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.02782154256
ACTUAL STEEL RATIO, 0.0021168565
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 4633.69565217
NUMBER OF BARS 14.7495113565
SAY 15
B. ALONG SHORT DIRECTION, B
CRITICAL WIDTH FOR MOMENT CAPACITY 1250
ULTIMATE MOMENT 153.791756466
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.02782154256
ACTUAL STEEL RATIO, 0.0021168565
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 4633.69565217
NUMBER OF BARS 14.7495113565
SAY 15
15 20 mm FOR SERVICE LOA
REINFORCEMENTS
15 20 mm NODE

21
21 MPA
23.544 KN/M3
16 KN/M3
276 MPA FOR ULTIMATE L
20 MM NODE
96 KPA
1.5 M
0.85

400 MM
400 MM 21
1

KPA

FOOTING
AFE FOR BEAM SHEAR

SAFE FOR PUNCHING

-5438522250 5617065782
0.02782154256 -1.722736797

20 mm bars
-5438522250 5617065782
0.02782154256 -1.722736797

20 mm bars
FOR SERVICE LOAD (UNFACTORED LOAD)
L/C FY MX MY
1 (EQX) -28.247 0 0
2 (EQZ) -0.346 0 0
3 (DL) 328.09 0 0
4 (LL) 108.214 0 0
5 (RLL) 8.048 0 0

FOR ULTIMATE LOAD (FACTORED LOAD)


L/C FY (PU) MX (MUX) MY (MUY)
6 459.326 0 0
7 570.875 0 0
8 460.692 0 0
9 419.568 0 0
10 476.062 0 0
11 447.469 0 0
12 448.161 0 0
13 323.528 0 0
14 267.034 0 0
15 295.627 0 0
16 294.935 0 0

You might also like