FOOTING DIMENSIONS

FOOTING NUMBER REINFORCEMENTS


L W T
F5 2350 2350 280

DATA AND SPECIFICATIONS


ULTIMATE CONCRETE STRENGTH, FC'
UNIT WEIGHT OF CONCRETE, W
ASSUMED UNIT WEIGHT OF SOIL
YIELD STRENGTH OF BARS, FY
BAR DIAMETER
ALLOWABLE SOIL PRESSURE, QA (ASSUMED)
ASSUME DEPTH OF FOOTING BASE FROM THE FINISH GROUND, DF
B, (IF FC' LESS THAN OR EQUAL TO 30 MPA)
COLUMN DIMENSIONS:
LONG SIDE, C
SHORT SIDE, L
RATIO, BC=C/L

DESIGN AND CALCULATIONS


A. SERVICE LOAD COMBINATION (LOAD COMBO SERIES 300)
AXIAL LOAD, PA 352.599 KN
BENDING MOMENT, MAY 0 KN.M
BENDING MOMENT, MAX 0 KN.M

B. COMBINATION (FACTORED)
AXIAL LOAD, PU 365.858 KN
BENDING MOMENT, MUY 0 KN.M
BENDING MOMENT, MUX 0 KN.M

C. FOOTING DESIGN
1. TRIAL DIMENSIONS
B 2.35 M
L 2.35 M
T 0.28 M

2. PROPORTIONING OF FOOTING
EFFECTIVE SOIL PRESSURE, QE 69.88768

3. CHECK ALLOWABLE SOIL PRESSURE ON EACH CORNER OF FOOTING


PA/BL 63.847713898 KPA
6MAX/BL2 0 KPA
6MAY/BL2 0 KPA
CORNER A, QA 63.847713898 KPA SAFE
CORNER B, QB 63.847713898 KPA SAFE
CORNERC, QC 63.847713898 KPA SAFE
CORNER D, QD 63.847713898 KPA SAFE

4. AVERAGE ULTIMATE SOIL PRESSURE


PU/BL 66.248619285 KPA
6MUX/BL2 0 KPA
6MUY/BL2 0 KPA
CORNER A, QA 66.248619285 KPA SAFE
CORNER B, QB 66.248619285 KPA SAFE
CORNERC, QC 66.248619285 KPA SAFE
CORNER D, QD 66.248619285 KPA SAFE
THEREFORE , USE 66.248619285 KPA

5. CHECK THCKNESS
A. BY BEAM SHEAR (ONE-WAY SHEAR)
EFFECTIVE DEPTH, D 197 MM
ALLOWABLE SHEAR STRENGTH, VA 175.02403198 KN
CRITICAL WIDTH FOR SHEAR STRESS,X 778 MM
ACTUAL SHEAR FORCE, VU 121.12235064 KN
THEREFORE, THE FOOTING IS SAFE FOR BEAM SHEA

B. PUNCHING SHEAR (TWO-WAY SHEAR)


BO 2388 MM
ALLOWABLE PUNCHIING FORCE, VP
VP 355.70841564 KN
VP 533.56262346 KN
THEREFORE, VPA 355.70841564 KN
ACTUAL PUNCHING SHEAR, VP 342.24639585 KN
THEREFORE, THE FOOTING IS SAFE FOR PUNCHING

6. STEEL REQUIREMENTS
A. ALONG LONG DIRECTION, L
CRITICAL WIDTH FOR MOMENT CAPACITY 975
ULTIMATE MOMENT 73.9986726064
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.04189455066
ACTUAL STEEL RATIO, 0.00318762885
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 2348.29710145
NUMBER OF BARS 11.6794716108
SAY 12
B. ALONG SHORT DIRECTION, B
CRITICAL WIDTH FOR MOMENT CAPACITY 975
ULTIMATE MOMENT 73.9986726064
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.04189455066
ACTUAL STEEL RATIO, 0.00318762885
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 2348.29710145
NUMBER OF BARS 11.6794716108
SAY 12
12 16 mm FOR SERVICE LOA
REINFORCEMENTS
12 16 mm NODE

25
21 MPA
23.544 KN/M3
16 KN/M3
276 MPA FOR ULTIMATE L
16 MM NODE
96 KPA
1.5 M
0.85

400 MM
400 MM 25
1

KPA

FOOTING
AFE FOR BEAM SHEAR

SAFE FOR PUNCHING

-1723701735 1808913912
0.04189455066 -1.736809805

16 mm bars
-1723701735 1808913912
0.04189455066 -1.736809805

16 mm bars
FOR SERVICE LOAD (UNFACTORED LOAD)
L/C FY MX MY
1 (EQX) 86.695 0 0
2 (EQZ) -0.076 0 0
3 (DL) 208.871 0 0
4 (LL) 57.033 0 0
5 (RLL) 4.952 0 0

FOR ULTIMATE LOAD (FACTORED LOAD)


L/C FY (PU) MX (MUX) MY (MUY)
6 292.42 0 0
7 344.375 0 0
8 287.085 0 0
9 365.858 0 0
10 192.467 0 0
11 279.086 0 0
12 279.238 0 0
13 101.288 0 0
14 274.679 0 0
15 188.06 0 0
16 187.908 0 0