Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

FOOTING DIMENSIONS

FOOTING NUMBER REINFORCEMENTS


L W T
F7 2600 2600 350

DATA AND SPECIFICATIONS


ULTIMATE CONCRETE STRENGTH, FC'
UNIT WEIGHT OF CONCRETE, W
ASSUMED UNIT WEIGHT OF SOIL
YIELD STRENGTH OF BARS, FY
BAR DIAMETER
ALLOWABLE SOIL PRESSURE, QA (ASSUMED)
ASSUME DEPTH OF FOOTING BASE FROM THE FINISH GROUND, DF
B, (IF FC' LESS THAN OR EQUAL TO 30 MPA)
COLUMN DIMENSIONS:
LONG SIDE, C
SHORT SIDE, L
RATIO, BC=C/L

DESIGN AND CALCULATIONS


A. SERVICE LOAD COMBINATION (LOAD COMBO SERIES 300)
AXIAL LOAD, PA 348.184 KN
BENDING MOMENT, MAY 0 KN.M
BENDING MOMENT, MAX 0 KN.M

B. COMBINATION (FACTORED)
AXIAL LOAD, PU 425.274 KN
BENDING MOMENT, MUY 0 KN.M
BENDING MOMENT, MUX 0 KN.M

C. FOOTING DESIGN
1. TRIAL DIMENSIONS
B 2.6 M
L 2.6 M
T 0.35 M

2. PROPORTIONING OF FOOTING
EFFECTIVE SOIL PRESSURE, QE 69.3596

3. CHECK ALLOWABLE SOIL PRESSURE ON EACH CORNER OF FOOTING


PA/BL 51.506508876 KPA
6MAX/BL2 0 KPA
6MAY/BL2 0 KPA
CORNER A, QA 51.506508876 KPA SAFE
CORNER B, QB 51.506508876 KPA SAFE
CORNERC, QC 51.506508876 KPA SAFE
CORNER D, QD 51.506508876 KPA SAFE

4. AVERAGE ULTIMATE SOIL PRESSURE


PU/BL 62.91035503 KPA
6MUX/BL2 0 KPA
6MUY/BL2 0 KPA
CORNER A, QA 62.91035503 KPA SAFE
CORNER B, QB 62.91035503 KPA SAFE
CORNERC, QC 62.91035503 KPA SAFE
CORNER D, QD 62.91035503 KPA SAFE
THEREFORE , USE 62.91035503 KPA

5. CHECK THCKNESS
A. BY BEAM SHEAR (ONE-WAY SHEAR)
EFFECTIVE DEPTH, D 265 MM
ALLOWABLE SHEAR STRENGTH, VA 260.48505894 KN
CRITICAL WIDTH FOR SHEAR STRESS,X 835 MM
ACTUAL SHEAR FORCE, VU 136.57838077 KN
THEREFORE, THE FOOTING IS SAFE FOR BEAM SHEA

B. PUNCHING SHEAR (TWO-WAY SHEAR)


BO 2660 MM
ALLOWABLE PUNCHIING FORCE, VP
VP 532.99250522 KN
VP 799.48875783 KN
THEREFORE, VPA 532.99250522 KN
ACTUAL PUNCHING SHEAR, VP 397.45346825 KN
THEREFORE, THE FOOTING IS SAFE FOR PUNCHING

6. STEEL REQUIREMENTS
A. ALONG LONG DIRECTION, L
CRITICAL WIDTH FOR MOMENT CAPACITY 1100
ULTIMATE MOMENT 98.9579884615
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.02820693336
ACTUAL STEEL RATIO, 0.00214617971
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 3494.92753623
NUMBER OF BARS 11.1246998628
SAY 12
B. ALONG SHORT DIRECTION, B
CRITICAL WIDTH FOR MOMENT CAPACITY 1100
ULTIMATE MOMENT 98.9579884615
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.02820693336
ACTUAL STEEL RATIO, 0.00214617971
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 3494.92753623
NUMBER OF BARS 11.1246998628
SAY 12
12 20 mm FOR SERVICE LOA
REINFORCEMENTS
12 20 mm NODE

42
21 MPA
23.544 KN/M3
16 KN/M3
276 MPA FOR ULTIMATE L
20 MM NODE
96 KPA
1.5 M
0.85

400 MM
400 MM 42
1

KPA

FOOTING
AFE FOR BEAM SHEAR

SAFE FOR PUNCHING

-3450856500 3565715434
0.02820693336 -1.723122188

20 mm bars
-3450856500 3565715434
0.02820693336 -1.723122188

20 mm bars
FOR SERVICE LOAD (UNFACTORED LOAD)
L/C FY MX MY
1 (EQX) 21.744 0 0
2 (EQZ) 29.029 0 0
3 (DL) 225.137 0 0
4 (LL) 94.018 0 0
5 (RLL) 9.363 0 0

FOR ULTIMATE LOAD (FACTORED LOAD)


L/C FY (PU) MX (MUX) MY (MUY)
6 315.192 0 0
7 425.274 0 0
8 332.154 0 0
9 338.918 0 0
10 295.429 0 0
11 346.203 0 0
12 288.144 0 0
13 180.879 0 0
14 224.367 0 0
15 173.594 0 0
16 231.653 0 0