FOOTING DIMENSIONS

FOOTING NUMBER REINFORCEMENTS


L W T
F6 2600 2600 300

DATA AND SPECIFICATIONS


ULTIMATE CONCRETE STRENGTH, FC'
UNIT WEIGHT OF CONCRETE, W
ASSUMED UNIT WEIGHT OF SOIL
YIELD STRENGTH OF BARS, FY
BAR DIAMETER
ALLOWABLE SOIL PRESSURE, QA (ASSUMED)
ASSUME DEPTH OF FOOTING BASE FROM THE FINISH GROUND, DF
B, (IF FC' LESS THAN OR EQUAL TO 30 MPA)
COLUMN DIMENSIONS:
LONG SIDE, C
SHORT SIDE, L
RATIO, BC=C/L

DESIGN AND CALCULATIONS


A. SERVICE LOAD COMBINATION (LOAD COMBO SERIES 300)
AXIAL LOAD, PA 341.883 KN
BENDING MOMENT, MAY 0 KN.M
BENDING MOMENT, MAX 0 KN.M

B. COMBINATION (FACTORED)
AXIAL LOAD, PU 418.041 KN
BENDING MOMENT, MUY 0 KN.M
BENDING MOMENT, MUX 0 KN.M

C. FOOTING DESIGN
1. TRIAL DIMENSIONS
B 2.6 M
L 2.6 M
T 0.3 M

2. PROPORTIONING OF FOOTING
EFFECTIVE SOIL PRESSURE, QE 69.7368

3. CHECK ALLOWABLE SOIL PRESSURE ON EACH CORNER OF FOOTING


PA/BL 50.574408284 KPA
6MAX/BL2 0 KPA
6MAY/BL2 0 KPA
CORNER A, QA 50.574408284 KPA SAFE
CORNER B, QB 50.574408284 KPA SAFE
CORNERC, QC 50.574408284 KPA SAFE
CORNER D, QD 50.574408284 KPA SAFE

4. AVERAGE ULTIMATE SOIL PRESSURE


PU/BL 61.840384615 KPA
6MUX/BL2 0 KPA
6MUY/BL2 0 KPA
CORNER A, QA 61.840384615 KPA SAFE
CORNER B, QB 61.840384615 KPA SAFE
CORNERC, QC 61.840384615 KPA SAFE
CORNER D, QD 61.840384615 KPA SAFE
THEREFORE , USE 61.840384615 KPA

5. CHECK THCKNESS
A. BY BEAM SHEAR (ONE-WAY SHEAR)
EFFECTIVE DEPTH, D 215 MM
ALLOWABLE SHEAR STRENGTH, VA 211.33693461 KN
CRITICAL WIDTH FOR SHEAR STRESS,X 885 MM
ACTUAL SHEAR FORCE, VU 142.294725 KN
THEREFORE, THE FOOTING IS SAFE FOR BEAM SHEA

B. PUNCHING SHEAR (TWO-WAY SHEAR)


BO 2460 MM
ALLOWABLE PUNCHIING FORCE, VP
VP 399.91450704 KN
VP 599.87176055 KN
THEREFORE, VPA 399.91450704 KN
ACTUAL PUNCHING SHEAR, VP 394.65142053 KN
THEREFORE, THE FOOTING IS SAFE FOR PUNCHING

6. STEEL REQUIREMENTS
A. ALONG LONG DIRECTION, L
CRITICAL WIDTH FOR MOMENT CAPACITY 1100
ULTIMATE MOMENT 97.274925
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.04179360195
ACTUAL STEEL RATIO, 0.00317994797
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 2835.50724638
NUMBER OF BARS 9.02569988868
SAY 10
B. ALONG SHORT DIRECTION, B
CRITICAL WIDTH FOR MOMENT CAPACITY 1100
ULTIMATE MOMENT 97.274925
DESIGN ULTIMATE MOMENT CAPACITY
REINFORCEMENT INDEX 0.04179360195
ACTUAL STEEL RATIO, 0.00317994797
MINIMUM STEEL RATIO 0.00507246377
THEREFORE, USE STEEL RATIO 0.00507246377
STEEL AREA 2835.50724638
NUMBER OF BARS 9.02569988868
SAY 10
10 20 mm FOR SERVICE LOA
REINFORCEMENTS
10 20 mm NODE

43
21 MPA
23.544 KN/M3
16 KN/M3
276 MPA FOR ULTIMATE L
20 MM NODE
96 KPA
1.5 M
0.85

400 MM
400 MM 43
1

KPA

FOOTING
AFE FOR BEAM SHEAR

SAFE FOR PUNCHING

-2271496500 2383518644
0.04179360195 -1.736708856

20 mm bars
-2271496500 2383518644
0.04179360195 -1.736708856

20 mm bars
FOR SERVICE LOAD (UNFACTORED LOAD)
L/C FY MX MY
1 (EQX) -3.609 0 0
2 (EQZ) 28.205 0 0
3 (DL) 220.466 0 0
4 (LL) 93.212 0 0
5 (RLL) 8.686 0 0

FOR ULTIMATE LOAD (FACTORED LOAD)


L/C FY (PU) MX (MUX) MY (MUY)
6 308.652 0 0
7 418.041 0 0
8 325.063 0 0
9 307.556 0 0
10 314.774 0 0
11 339.369 0 0
12 282.96 0 0
13 202.028 0 0
14 194.81 0 0
15 170.215 0 0
16 226.624 0 0

You might also like