MORTOR

2009-2010
Sl. No. Description
Rate
Unit
Rs. Ps.
1.1 KSRB 0.5-1.1 : Providing cement mortar of mix 1:1 (1 cement : 1 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 6940.00
10/P.No.2/1.1)

1.2 KSRB 0.5-1.2 : Providing cement mortar of mix 1:2 (1 cement : 2 sand)
including cost all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 5060.00
10/P.No.2/1.2)

1.3 KSRB 0.5-1.3 : Providing cement mortar of mix 1:3 (1 cement : 3 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 4130.00
10/P.No.2/1.3)

1.4 KSRB 0.5-1.4 : Providing cement mortar of mix 1:4 (1 cement : 4 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 3340.00
10/P.No.2/1.4)

1.5 KSRB 0.5-1.5 : Providing cement mortar of mix 1:5 (1 cement : 5 sand)
including cost of all materials, labour charges, HOM of Machinery complete
as per Specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 2920.00
10/P.No.2/1.5)

1.6 KSRB 0.5-1.6 : Providing cement mortar of mix 1:6 (1 cement : 6 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 2550.00
10/P.No.2/1.6)

1.7 KSRB 0.5-1.7 : Providing cement mortar of mix 1:8 (1 cement : 8 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 2190.00
10/P.No.2/1.7)

1.8 KSRB 0.5-1.8 : Providing cement mortar of mix 1:10 (1 cement : 10 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2009- Cum 1950.00
10/P.No.2/1.8)

1.9 KSRB 0.5-2.1 : Providing lime mortar of mix 1:1 (1 lime putty : 1 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 (PWD SR 2009- Cum 3050.00
10/P.No.2/1.9)

1.10 KSRB 0.5-2.2 : Providing lime mortar of mix 1:2 (1 lime putty : 2 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 (PWD SR 2009- Cum 2530.00
10/P.No.2/1.10)

1.11 KSRB 0.5-2.3 : Providing lime mortar of mix 1:3 (1 lime putty : 3 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 (PWD SR 2009- Cum 2260.00
10/P.No.2/1.11)
1.12 KSRB 0.5-3.1 : Providing lime surkhi mortar of mix 1:1 (1 lime putty : 1
surkhi) including cost of all materials, labour charges, HOM of machinery
complete as per specifications. Specification No. KBS (PWD SR 2009- Cum 2780.00
10/P.No.2/1.12)

1.13 KSRB 0.5-3.2 : Providing lime surkhi mortar of mix 1:2 (1 lime putty : 2
surkhi) including cost of all materials, labour charges, HOM of machinery
complete as per specifications. Specification No. KBS (PWD SR 2009- Cum 2160.00
10/P.No.2/1.13)

1.14 KSRB 0.5-3.3 : Providing lime surkhi mortar of mix 1:3 (1 lime putty : 3
surkhi) including cost of all materials, labour charges, HOM of machinery
complete as per specifications. Specification No. KBS (PWD SR 2009- Cum 1860.00
10/P.No.2/1.14)

1.15 KSRB 0.5-4.1 : Providing lime surkhi sand mortar of mix 1:1:1 (1 lime putty
: 1 surkhi : 1 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS (PWD Cum 2320.00
SR 2009-10/P.No.2/1.15)

1.16 KSRB 0.5-4.2 : Providing lime surkhi sand mortar of mix 1:1:2 (1 lime putty
: 1 surkhi : 2 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS (PWD Cum 1820.00
SR 2009-10/P.No.2/1.16)

1.17 KSRB 0.5-5.1 : Providing Cement mortar with stone dust of mix 1:2 (1
cement : 2 stone dust) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS (PWD Cum 4490.00
SR 2009-10/P.No.2/1.17)

1.18 KSRB 0.5-6.1 : Providing Cement lime Mortar of mix 1:1:3 (1 cement : 1
lime putty : 3 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 4480.00
(PWD SR 2009-10/P.No.3/1.18)

1.19 KSRB 0.5-6.2 : Providing Cement lime Mortar of mix 1:1:4 (1 cement : 1
lime putty : 4 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 4450.00
(PWD SR 2009-10/P.No.3/1.19)

1.20 KSRB 0.5-6.3 : Providing Cement lime Mortar of mix 1:1:5 (1 cement : 1
lime putty : 5 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3840.00
(PWD SR 2009-10/P.No.3/1.20)

1.21 KSRB 0.5-6.4 : Providing Cement lime Mortar of mix 1:1:6 (1 cement : 1
lime putty : 6 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3350.00
(PWD SR 2009-10/P.No.3/1.21)

1.22 KSRB 0.5-6.5 : Providing Cement lime Mortar of mix 1:1:7 (1 cement : 1
lime putty : 7 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3080.00
(PWD SR 2009-10/P.No.3/1.22)

1.23 KSRB 0.5-6.6 : Providing Cement lime Mortar of mix 1:1:8 (1 cement : 1
lime putty : 8 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 2830.00
(PWD SR 2009-10/P.No.3/1.23)
1.24 KSRB 0.5-6.7 : Providing Cement lime Mortar of mix 1:2:9 (1 cement : 2
lime putty : 9 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3025.00
(PWD SR 2009-10/P.No.3/1.24)

1.25 KSRB 0.5-6.8 : Providing Cement lime Mortar of mix 1:3:12 (1 cement : 3
lime putty : 12 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 2860.00
(PWD SR 2009-10/P.No.3/1.25)

1.26 KSRB 0.5-7.1 : Providing white cement mortar with marble dust of mix 1:2
(1 white cement : 2 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 17600.00
No. KBS (PWD SR 2009-10/P.No.3/1.26)

1.27 KSRB 0.5-7.2 : Providing white cement mortar with marble dust of mix 1:3
(1 white cement : 3 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 13590.00
No. KBS (PWD SR 2009-10/P.No.3/1.27)

1.28 KSRB 0.5-7.3 : Providing white cement mortar with marble dust of mix 1:4
(1 white cement : 4 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 10440.00
No. KBS (PWD SR 2009-10/P.No.3/1.28)

1.29 KSRB 0.5-7.4 : Providing white cement mortar with marble dust of mix 1:5
(1 white cement : 5 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 8750.00
No. KBS (PWD SR 2009-10/P.No.3/1.29)

1.30 KSRB 0.5-8.1 : Providing fly ash sand mortar of mix 1:1.5:3 (1 cement : 1.5
fly ash : 3 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 2830.00
(PWD SR 2009-10/P.No.3/1.30)

1.31 KSRB 0.5-8.2 : Providing fly ash sand mortar of mix 1:2:4 (1 cement : 2 fly
ash : 4 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 2280.00
(PWD SR 2009-10/P.No.3/1.31)

1.32 KSRB 0.5-8.3 : Providing fly ash sand mortar of mix 1:2.5:5 (1 cement : 2.5
fly ash : 5 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 1980.00
(PWD SR 2009-10/P.No.3/1.32)

1.33 KSRB 0.5-8.4 : Providing fly ash sand mortar of mix 1:3:6.5 (1 cement : 3
fly ash : 6.5 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 1740.00
(PWD SR 2009-10/P.No.3/1.33)
1.34 Mud mortar Cum 69.00
EARTH WORK FOR BUILDINGS
2.0 EARTH WORK FOR BUILDINGS
2.1 KSRB 2-1.1 : Earthwork in surface excavation in ordinary soil for levelling
and lowering the ground manually (other than foundation of buildings,
culverts, road drains and trenches of pipe lines and cables) and removing
the excavated stuff to a distance not exceeding 50m and lift upto 1.5m
excavated surface levelled and neatly dressed, disposed earth to be Cum 84.00
levelled after breaking of clods and neatly dressed as per specifications.
Specification No. KBS 2.1(a) / 2.3.1 (PWD SR 2009-10/P.No.5/2.1)

2.2 KSRB -2-1.2 : Earthwork in surface excavation in hard soil for levelling and
lowering the ground manually (other than foundation of buildings, culverts,
road drains and trenches of pipe lines and cables) and removing the
excavated stuff to a distance not exceeding 50m and lift upto 1.5m
excavated surface levelled and neatly dressed, disposed earth to be Cum 118.00
levelled after breaking of clods and neatly dressed as per specifications.
Specification No. KBS 2.1(b) / 2.3.1 (PWD SR 2009-10/P.No.5/2.2)

2.3 KSRB -2-2.1 : Earthwork excavation for foundation of buildings, culverts,


water supply, sanitary lines and electrical conduits either in pits or in
trenches 1.5m and above in width, in ordinary soil not exceeding 1.5m in
depth including dressing the bottom and sides of pits and trenches,
stacking the excavated soil clear from edges of excavation with lead upto Cum 101.00
50m. after breaking of clods complete as per specifications. Specification
No. KBS 2.1(a) / 2.3.5 (PWD SR 2009-10/P.No.5/2.3)

2.4 KSRB 2-2.2 : Earthwork excavation for foundation of buildings, culverts,


water supply, sanitary lines and electrical conduits either in pits or in
trenches 1.5m and above in width, in hard soil not exceeding 1.5m in
depth including dressing the bottom and sides of pits and trenches,
stacking the excavated soil clear from edges of excavation with lead upto Cum 152.00
50m. after breaking of clods complete as per specifications. Specification
No. KBS 2.1(b) / 2.3.5 (PWD SR 2009-10/P.No.5/2.4)

2.5 KSRB 2-2.3 : Excavation 1.5m and above in width in soft rock by
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead Cum 320.00
upto 50m including cost of explosives, labour and HOM of equipment
complete as per specifications. Specification No. KBS 2.1.C / 2.9.4 / 2.18 /
2.19 (PWD SR 2009-10/P.No.5/2.5)

2.6 KSRB 2-2.4 : Excavation 1.5m and above in width in soft rock without
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead Cum 470.00
upto 50m including cost of labour complete as per specifications.
Specification No. KBS 2.1.C / 2.3.5 (PWD SR 2009-10/P.No.5/2.6)

2.7 KSRB 2-2.5 : Excavation 1.5m and above in width in hard rock by
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead Cum 315.00
upto 50m including cost of explosives, labour and HOM of equipment
complete as per specifications. Specification No. KBS 2.1.d / 2.3.4 / 2.18 /
2.19 (PWD SR 2009-10/P.No.5/2.7)
2.8 KSRB 2.2.6 : Excavation 1.5m and above in width in hard rock by
chiselling and / or wedging, where blasting is prohibited for foundation of
buildings, water supply, sanitary lines and electrical conduits either in pits
or in trenches 1.5 m. in depth, stacking the excavated stuff clear from the Cum 675.00
edge of excavation with lead upto 50m including cost of labour complete
as per specifications. (PWD SR 2009-10/P.No.5/2.8)

2.9 KSRB 2.2-7 : Benching hard rock 5 to 7.5 cm depth. for seating of
foundation including cost of all labour complete as per specifications. Sqm 720.00
Specification No. KBS 2.1.(a) / 2.3.1 (PWD SR 2009-10/P.No.6/2.9)

2.10 KSRB 2.3 : Filling available excavated earth (excluding rock) in sides of
foundations upto plinth in layers not exceeding 20 cms. in depth,
compacting each deposited layer by ramming after watering with lead upto Cum 68.00
50m and lift upto 1.5m including cost of all labour complete as per
specifications. (PWD SR 2009-10/P.No.6/2.10)

2.11 KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not
exceeding 20 cms. in depth, compacting each deposited layer by ramming
after watering with lead upto 50m and lift upto 1.5m including cost of all Cum 40.00
labour complete as per specifications allow 60% of rate considered under
item KSRB 2.3 (PWD SR 2009-10/P.No.6/2.11)

2.12 KSRB 2.5 : Earthwork excavation (in deposited soil) and filling sides of
foundation upto plinth in layers not exceeding 20cms. in depth, compacting
each deposited layer by ramming after watering with lead upto 50m. and
lift upto 1.5m including cost of all labour complete as per specifications. Cum 135.00
Specification No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 (PWD SR 2009-
10/P.No.6/2.12)

2.13 KSRB 2.6 : Providing and filling sand in foundation upto plinth to required
depth for sub soil treatment including watering ramming with lead upto
50m. and lift upto 1.5m complete as per specifications. Specification No. Cum 830.00
KBS 2.10.2 (PWD SR 2009-10/P.No.6/2.13)

2.14 KSRB 2.7 : Providing and removing shoring and shuttering for protecting
the sides of foundation trenches, wherever required, including cost of all
materials and labour complete as per specifications. Specification No. KBS Sqm 350.00
2.5/2.13 (PWD SR 2009-10/P.No.6/2.14)

2.15 KSRB 2.8 : Filling in foundation with granite/trap broken metal 100mm. and
down size, with approved sand including hand packing, ramming,
watering, including cost of all materials and labour with lead upto 50m. and Cum 970.00
lift of 1.5m complete as per specification. (PWD SR 2009-10/P.No.6/2.15)

2.16 KSRB 2.9 : Spreading and forming the excavated earth to required level,
slope for an average thickness of 75mm. in all classes of soils all-round
the building and low laying areas complete as per specifications. (PWD SR Sqm 3.15
2009-10/P.No.6/2.16)

2.17 KSRB 2.10 : Providing sand cement bed with 5% cement with a lead of 50
m. for all materials and lift of 1.5m machine mixed, laid in layers of 15cms.
thick and well compacted for foundation, including curing cost of materials Cum 1450.00
labour and HOM complete as per specifications. (PWD SR 2009-
10/P.No.6/2.17)
2.18 KSRB 2.11 : Providing sand cement bed with 10% cement with a lead of
50 m. for all materials and lift of 1.5m machine mixed, laid in layers of
15cms. thick and well compacted for foundation, including curing cost of Cum 1890.00
materials labour and HOM complete as per specifications. (PWD SR 2009-
10/P.No.6/2.18)

2.19 KSRB 2.12 : Providing sand piles with all leads and lift of 1.5m for
stabilising foundation after duly making 5 cms. dia holes to a depth of 1.2
to 1.5m at 0.5 m c to c and filling with sand and tamping wherever required Sqm 110.00
including cost of materials, labour complete as per specifications. (PWD
SR 2009-10/P.No.7/2.19)

2.20 KSRB 2.13 : Providing sand cement piles with all leads and lift of 1.5m
Sqm 91.19 for stabilising foundation bed after making 5 cms. dia holes to a
depth of 1.2 to 1.5m at 0.5 m c to c and filling with sand and 10% cement, Sqm 132.00
tamping wherever required including cost of materials, labour complete as
per specifications. (PWD SR 2009-10/P.No.7/2.20)

2.21 KSRB 2.14-1 : Extra for additional lift of 1.5m. or part thereof for
excavation in loose / soft or hard soil including cost of materials, labour Cum 6.70
complete as per specifications. (PWD SR 2009-10/P.No.7/2.21)

2.22 KSRB 2.14-2 : Extra for additional lift of 1.5m. or part thereof for
excavation in soft or hard rock including cost of materials, labour Cum 11.80
complete as per specifications. (PWD SR 2009-10/P.No.7/2.22)

2.23 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required
and utilising the remaining earth locally for the work in. (Depth upto 3m)
(PWD SR 2009-10/P.No.7/2.23)

2.23.1 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 28.00
and utilising the remaining earth locally for the work. Ordinary/Hard soil-
Mechanical Means (Depth upto 3m) (PWD SR 2009-10/P.No.7/2.23.1)

2.23.2 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 38.00
and utilising the remaining earth locally for the work. Ordinary Rock (not
requiring blasting) – Mechanical Means(PWD SR 2009-10/P.No.7/2.23.2)

2.23.3 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 395.00
and utilising the remaining earth locally for the work. Hard Rock (requiring
blasting) – Mechanical Means (PWD SR 2009-10/P.No.7/2.23.3)
2.23.4 Earth work in excavation of foundation of structures as per drawing and
technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 150.00
and utilising the remaining earth locally for the work. Marshy soil-
Mechanical Means (PWD SR 2009-10/P.No.7/2.23.4)

ANTITERMITE TREATMENT
3.0 ANTITERMITE TREATMENT

3.1 KSRB 3.1 : Supplying chloropyriphos emulisifiable concentrate of 20%, in


sealed containers including delivery as specified sales tax, transport,
Insurance and other levies complete as per specifications. (PWD SR 2009- L 265.00
10/P.No.9/3.1)

3.2 KSRB 3.2 : Providing and injecting chemical emulsion for Pre-
constructional Anti-Termite Treatment, creating continuous chemical
barrier under and around the column pits, walls, trenches, basement
excavation, top surface of the plinth filling, junction of wall and floor, along
the external perimeter of building, expansion joints, over the top surface of
consolidated earth on which apron is to be laid, surrounding of pipes and
conduits, with chloropyriphos emulsifiable concentrates of 20% Sqm 101.00
concentration, including cost of chemical, diluting in water to one percent
concentration, labour, HOM of equipments, complete as per speficiations.
(Plinth area of the building at ground floor only shall be measured)
Specification No. KBS : 3.2.6/3.2.7 (PWD SR 2009-10/P.No.9/3.2)

3.3 KSRB 3.3 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment along external walls where the apron is not
provided using chemical, emusltion at 7.5 Litre/ sqm of the vertical surface
of the substructure to a depth of 300mm. including excavation of channel
along the wall and redoing with chlorophyriphos emulsion concentrate 20% m 52.00
diluting in water to 1% concentration, including cost of chemicals, diluting
in water to one percent cocnentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.3 (PWD SR
2009-10/P.No.9/3.3)

3.4 KSRB 3.4 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment along external walls below concrete or masonry
apron using chemical emulsion at 2.25 litre/m including drilling and
plugging to holes, with chlorophyriphos emulsion concentrate 20% diluting
in water to 10% concentration, including cost of chemicals, diluting in water m 40.00
to one percent concentration, labour, HOM of equipments, complete as per
specifications. Specification No. KBS : 3.3.4 (PWD SR 2009-
10/P.No.9/3.4)

3.5 KSRB 3.5 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment of soil under existing floors using chemical
chemical emulsion at one litre/hole 30mm apart including drilling 12mm.
dia holes and plugging with cement mortar 1:2 proportion to mach with the
existing floors with chlorophyriphos emulsion concentrate 20%, including Sqm 203.00
cost of chemicals diluting in water to one percent concentration, labour,
HOM of equipments, complete as per specifications. (PWD SR 2009-
10/P.No.9/3.5)
3.6 KSRB 3.6 : Providing, injecting chemical emulsion for Pre-constructional
Anti - Termite Treatment of existing masonry using chemical emulsion at
one liter/ hole at 300 mm intervals including drilling of holes at 45 degree
and plugging them with cement mortar 1:2 to the full depth of the hole with
Chloropyriphos emulsifiable concentration 20% including cost of chemical m 63.00
diluting in water to one percent concentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.5 (PWD SR
2009-10/P.No.9/3.6)

3.7 KSRB 3.7 : Providing, injecting chemical emulsion for Pre-constructional


Anti - Termite Treatment at points of contacts of wood work by chemical
emulsion Chloropyriphos (in oil or kerosene based solution) at 0.5 liters
per hole by drilling 6mm. dia holes at downword angle of 45 degree at
150mm. c to c and sealing the same including cost of chemicals, diluting in m 153.00
water to one percent concentration, labour, HOM of equipments, complete
as per specifications. Specification No. KBS : 3.3.7 (PWD SR 2009-
10/P.No.10/3.7)

3.8 Providing general disinfection sevices, spraying of insecticide and


pesticide inside and outside thebuilding (files, bedbugs, liwards,
cockroaches, spiders caterpillars etc. including cost of materials labour
lead lift, hire charges of equipments etc., complete. (PWD SR 2009- Sqm 21.00
10/P.No.10/3.8)

CEMENT CONCRETE
4.0 CEMENT CONCRETE

4.1 KSRB 4-1.1 : Providing and laying in position plain cement concrete of
nominal mix 1:2:4 using 40mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 3890.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.1)

4.2 KSRB 4-1.2 : Providing and laying in position plain cement concrete of
nominal mix 1:3:6 using 40mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 3330.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.2)

4.3 KSRB 4-1.3 : Providing and laying in position plain cement concrete of
nominal mix 1:4:8 using 40mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 3060.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.3)

4.4 KSRB 4-1.4 : Providing and laying in position plain cement concrete of
nominal mix 1:5:10 using 40mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 2870.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.4)
4.5 KSRB 4-1.5 : Providing and laying in position plain cement concrete of
nominal mix 1:1.5:3 using 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 4360.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.5)

4.6 KSRB 4-1.6 : Providing and laying in position plain cement concrete of
nominal mix 1:2:4 using 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 3950.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.6)

4.7 KSRB 4-1.7 : Providing and laying in position plain cement concrete of
nominal mix 1:3:6 using 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation and plinth, including cost of all materials, labour, Cum 3390.00
HOM of machinery, curing complete as per specification. Specification No.
KBS 4.1, 4.2 (PWD SR 2009-10/P.No. 12/4.7)

4.8 KSRB 4-1.8 : Extra for laying cement concrete under water including cost
of pumping or dewatering and clearing slush as per specifications. Details
of cost for depth of water 0.3 metres bailing out Specification No.KBS 4.2, Cum 57.00
4.8 (PWD SR 2009-10/P.No. 12/4.8)

4.9 KSRB 4-1.9 : Extra for laying cement concrete under foul conditions.
Cum 74.00
(PWD SR 2009-10/P.No. 12/4.9)

4.10 KSRB 4.2.1 : Providing and laying in position reinforced cement concrete
of nominal mix 1:1:2 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for all works in foundation plinth and ground floor level for Roof
Slabs, Staircase,Lintels,retaining walls, return walls, walls (any thickness)
including attached plasters, columns, piers, abutments, pillars, posts,
struts, buttresses, string or lacing courses, parapets, coping, bed blocks, Cum 5150.00
anchor blocks, plain window cills, fillets etc., including cost of all materials,
labour, HOM of machinery, curing complete as per specification.
Specification No. KBS 4.1, 4.6 (PWD SR 2009-10/P.No. 12/4.10)

4.11 KSRB 4.2.1 : Providing and laying in position reinforced cement concrete
of nominal mix 1:1.1/2:3 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for all works in foundation plinth and ground floor level for Roof
Slabs, Staircase,Lintels,retaining walls, return walls, walls (any thickness)
including attached plasters, columns, piers, abutments, pillars, posts,
struts, buttresses, string or lacing courses, parapets, coping, bed blocks, Cum 4420.00
anchor blocks, plain window cills, fillets etc., including cost of all materials,
labour, HOM of machinery, curing complete as per specification.
Specification No. KBS 4.1, 4.6 (PWD SR 2009-10/P.No. 12/4.11)
4.12 KSRB 4.2.3: Providing and laying in position reinforced cement concrete of
nominal mix 1:2:4 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for all works in foundation plinth and ground floor level for
retaining walls, return walls, walls (any thickness) including attached
plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string Cum 4010.00
or lacing courses, parapets, coping, bed blocks, anchor blocks, plain
window cills, fillets etc., including cost of all materials, labour, HOM of
machinery, curing complete as per specification. Specification No. KBS
4.1, 4.6 (PWD SR 2009-10/P.No. 13/4.12)

4.13 KSRB 4.2.4 : Providing and laying in position reinforced cement concrete
of nominal mix 1:3:6 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for all works in foundation plinth and ground floor level for
retaining walls, return walls, walls (any thickness) including attached
plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string
Cum 3460.00
or lacing courses, parapets, coping, bed blocks, anchor blocks, plain
window cills, fillets etc., including cost of all materials, labour, HOM of
machinery, curing complete as per specification. Specification No. KBS
4.1, 4.6 (PWD SR 2009-10/P.No. 13/4.13)

4.14 KSRB 4.2.5 : Providing and laying in position reinforced cement concrete
of nominal mix 1:2:4 with 40mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for all works in foundation plinth and ground floor level for
retaining walls, return walls, walls (any thickness) including attached
plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string Cum 3950.00
or lacing courses, parapets, coping, bed blocks, anchor blocks, plain
window cills, fillets etc., including cost of all materials, labour, HOM of
machinery, curing complete as per specification. Specification No. KBS
4.1, 4.6 (PWD SR 2009-10/P.No. 13/4.14)

4.15 KSRB 4.2.6 : Providing and laying in position reinforced cement concrete
of nominal mix 1:3:6 with 40mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for all works in foundation plinth and ground floor level for
retaining walls, return walls, walls (any thickness) including attached
plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string
or lacing courses, parapets, coping, bed blocks, anchor blocks, plain Cum 3400.00
window cills, fillets etc., including cost of all materials, labour, HOM of
machinery, curing complete as per specification. Specification No. KBS
4.1, 4.6 (PWD SR 2009-10/P.No. 13/4.15)

4.16 KSRB 4.2.7 : Providing and laying in position reinforced cement concrete
of nominal mix 1:1:2 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for R.C.C. beams, columns of all sizes in foundation plinth and
superstructure ground floor level for Roof Slabs, Stair case, Cum 5150.00
Lintels,columns, including cost of all materials, labour, HOM of machinery,
curing, complete as per specification. Specification No. KBS 4.1, 4.6 (PWD
SR 2009-10/P.No. 13/4.16)
4.17 KSRB 4.2.8 : Providing and laying in position reinforced cement concrete
of nominal mix 1:1.5:3 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for R.C.C. beams, columns of all sizes in foundation plinth and
superstructure ground floor level for Roof Slabs, Stair case, Cum 4420.00
Lintels,columns, including cost of all materials, labour, HOM of machinery,
curing, complete as per specification. Specification No. KBS 4.1, 4.6 (PWD
SR 2009-10/P.No. 13/4.17)

4.18 KSRB 4.2.9 : Providing and laying in position reinforced cement concrete
of nominal mix 1:2:4 with 20mm and down size graded granite metal
machine mixed, concrete laid in layers not exceeding 15 cms. thick,
vibrated for R.C.C. beams, columns of all sizes in foundation plinth and
superstructure ground floor level forfor Roof Slabs, Stair case, Cum 4010.00
Lintels,columns,including cost of all materials, labour,, HOM of machinery,
curing, complete as per specification. Specification No. KBS 4.1, 4.6 (PWD
SR 2009-10/P.No. 13/4.18)

4.19 KSRB 4.2.10 : Providing and laying in position reinforced cement concrete
of nominal mix 1:1.5:3 (M20) with 12mm and down size graded granite
metal machine mixed, well compacted for plain chajja of 7.5 cms. average
thickness, upto ground floor level, including cost of all materials, labour, Sqm 340.00
HOM of machinery, finishing, curing, complete as per specification.
Specification No. KBS 4.1, 4.6 (PWD SR 2009-10/P.No. 13/4.19)

4.20 KSRB 4.2.11 : Providing and laying in position reinforced cement concrete
of mix 1:1.5:3 (M20) with 12mm and down size graded granite metal
machine mixed, well compacted for plain chajja of 8.5 cms. average
thickness, upto ground floor level, including cost of all materials, labour, Sqm 350.00
HOM of machinery, finishing, curing, complete as per specification.
Specification No. KBS 4.1, 4.6 (PWD SR 2009-10/P.No. 14/4.20)

4.21 KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chajja
with plastering (labour charges only) as per specification. (PWD SR 2009- m 10.80
10/P.No. 14/4.21)

4.22 KSRB 4-3.1 : Extra if vibrator is used for item No. 4.1 to 4.8 as per as per
specification. Specification No. KBS 4.2.6 (PWD SR 2009-10/P.No. Cum 12.70
14/4.22)

4.23 KSRB 4-3.2 : Deduct where machine mixing is not done Specification No.
Cum 12.70
KBS 4.2.2.5/4.3.2.2 (PWD SR 2009-10/P.No. 14/4.23)

4.24 KSRB 4-4.1 : Extra for use of water proofing compound in Cement
concrete of mix 1:1:2 at one kg of compound per bag of cement (PWD SR Cum 255.00
2009-10/P.No. 14/4.24)

4.25 KSRB 4-4.2 : Extra for use of water proofing compound in Cement
concrete of mix 1:1.5:3 at one kg of compound per bag of cement (PWD Cum 189.00
SR 2009-10/P.No. 14/4.25)

4.26 KSRB 4-4.3 : Extra for use of water proofing compound in Cement
concrete of mix 1:2:4 at one kg of compound per bag of cement (PWD SR Cum 150.00
2009-10/P.No. 14/4.26)
4.27 KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick with
6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically
fixing chicken mesh for drop chajja, facia, backing to cup boards including
cost of all materials, labour, providing and removing from work HOM of Sqm 780.00
machineries, curing, complete as per specification. (PWD SR 2009-
10/P.No. 14/4.27)

4.28 KSRB 4-6.1 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for foundations, footings, bases of
columns for mass concrete including cost of all materials, labour complete Sqm 138.00
as per specification. Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No.
14/4.28)

4.29 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as suspended
floors, roofs, landings, balconies and likes, thickness upto 200 mm
including cost of all materials, labour complete as per specification. Sqm 202.00
Specification No. KBS 4-6.2 (PWD SR 2009-10/P.No. 14/4.29)

4.30 KSRB 4-6.3 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as suspended
floors, roofs, landings, balconies and likes, thickness above 200 mm
including cost of all materials, labour complete as per specification. Sqm 220.00
Specification No. KBS 4-6.2 (PWD SR 2009-10/P.No. 14/4.30)

4.31 KSRB 4-6.4 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as wall at any
thickness, including attached pilasters, buttresses, plinth and string Sqm 169.00
courses cost of all materials, labour complete as per specification.
Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No. 14/4.31)

4.32 KSRB 4-6.5 : Providing and removing centering, shuttering, strutting,


propping etc., for columns, pillars, piers, abutments, post and struts,
square / rectangular / polygon in plan including cost of all materials, labour Sqm 210.00
complete as per specification Specification No. KBS 4.6.2 (PWD SR
2009-10/P.No. 15/4.32)

4.33 KSRB 4-6.6 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for columns, pillars, piers, post
and struts, circular or curved in plan including cost of all materials, labour Sqm 530.00
complete as per specification Specification No. KBS 4.6.2 (PWD SR
2009-10/P.No. 15/4.33)

4.34 KSRB 4-6.7 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for sides and soffits of beams
haunchings, cantilever girders, bressumers and lintels not exceeding 1m
in depth including cost of all materials, labour complete as per Sqm 150.00
specification Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No.
15/4.34)

4.35 KSRB 4-6.8 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for sides and soffits of beams
beams haunchings, cantilever, girders, bressumers and lintels exceeding
1m in depth including cost of all materials, labour complete as per Sqm 198.00
specification Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No.
15/4.35)
4.36 KSRB 4-6.9 : Providing and removing centering, shuttering, strutting,
propping etc., for edges of slabs and breaks in floor, cills, plinth including
cost of all materials, labour complete as per specification. Specification No. Sqm 420.00
KBS 4.6.2 (PWD SR 2009-10/P.No. 15/4.36)

4.37 KSRB 4-6.10 : Providing and removing centering, shuttering, strutting,


propping etc., for chajjas, corbles etc., including edges including cost of all
materials, labour complete as per specification. Specification No. KBS Sqm 156.00
4.6.2 (PWD SR 2009-10/P.No. 15/4.37)

4.38 KSRB 4-6.11 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for Stairs (excluding landing)
except spiral staircase including cost of all materials, labour complete as Sqm 290.00
per specification. Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No.
15/4.38)

4.39 KSRB 4-6.12 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for cornices and mouldings
including cost of all materials, labour complete as per specification. Sqm 317.00
Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No. 15/4.39)

4.40 KSRB 4-6.13 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for vertical fins and vertical fibs
and vertical sun breakers including cost of all materials, labour complete Sqm 255.00
as per specification. Specification No. KBS 4.6.2 (PWD SR 2009-10/P.No.
15/4.40)

4.41 KSRB 4-6.14 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for sloping or battering surface
including folded plates where inclination to horizontal plane does not
exceed 30 degree requiring shuttering only on the under side including Sqm 240.00
cost of all materials, labour complete as per specifications. Specification
No. KBS 4.6.2 (PWD SR 2009-10/P.No.15/4.41)

4.42 KSRB 4-6.15 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for where inclination to horizontal
plane exceeds 30 degree (where shuttering may be provided both on
under side and upper side if required) including cost of all materials, labour Sqm 375.00
complete as per specifications. Specification No. KBS 4.6.2 (PWD SR
2009-10/P.No. 16/4.42)

4.43 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using
10-15 cms. dia best quality casurina poles of 4m over all length (3m + 05m
in to the ground), the distance between two rows being 1.25m and spacing
of posts being 2m in both rows with 2 horizontal posts with 0.5 mm overlap
on either side and braces at 2m c to c including longitudinal and transveres m 162.00
middle braces to step up and providing platform with casurina poles, forms
tied up using coir rope complete as per specification (PWD SR 2009-
10/P.No. 16/4.43)

4.44 KSRB 4-8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length (3m+0.5m
projection + 0.5m in to the ground) the distance between two rows being
1.25m and spacing of post being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2m c to including
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications. Specification No. KBS (PWD SR 2009-10/P.No. 16/4.44)
4.44.1 KSRB 4-8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length (3m+0.5m
projection + 0.5m in to the ground) the distance between two rows being
1.25m and spacing of post being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2m c to including
longitudinal and transveres middle braces to step up and providing Cum 137.00
platform with casurina poles, forms tied up using coir rope complete as per
specifications for non modular brick work (Non modular standard bricks :
4x0.23x3 = 2.76 cum) (PWD SR 2009-10/P.No. 16/4.44.1)

4.44.2 KSRB 4-8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length (3m+0.5m
projection + 0.5m in to the ground) the distance between two rows being
1.25m and spacing of post being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2m c to including Cum
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications for modular brick work (Modular bricks : 4x0.2x3 = 2.4 cum)
(PWD SR 2009-10/P.No. 16/4.44.2)

4.44.3 KSRB 4.8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length (3m+0.5m
projection + 0.5m in to the ground) the distance between two rows being
1.25m and spacing of post being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2m c to including
Sqm 31.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications for non modular brick work (PWD SR 2009-10/P.No.
16/4.44.3)

4.44.4 KSRB 4.8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length (3m+0.5m
projection + 0.5m in to the ground) the distance between two rows being
1.25m and spacing of post being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2m c to including
Sqm
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications for modular brick work (PWD SR 2009-10/P.No. 16/4.44.4)

4.45 KSRB 4.9.1 : Providing mild steel reinforcement for RCC work including
straightening, curring, bending, hooking, placing in position, lapping and /
or welding wherever required, tying with binding wire and anchoring to the
adjoining members wherever necessary complete as per design (laps,
hooks and wastage shall not be measured and paid) cost of materials,
q 4650.00
labour, HOM of machinery complete as per specifications. Specification
No. KBS 4.6.3 (PWD SR 2009-10/P.No. 16/4.45)

4.46 KSRB 4.9.2 : Providing TMT steel reinforcement for RCC work including
straightening, cutting, bending, hooking, placing in position, lapping and /
or welding wherever required, tying with binding wire and anchoring to the
adjoining members wherever necessary complete as per design (laps,
hooks and wastage shall not be measured and paid) cost of materials, q 4710.00
labour, HOM of machinery complete as per specifications. Specification
No. KBS 4.6.3 (PWD SR 2009-10/P.No. 16/4.46)
4.47 Lift charges for steel of all diameters for additional floors over ground floor
per q floor height of 3.5 m. or part thereof cost of labour, complete as per q 25.00
specification (P.W.D. SR 2009-10/P.No. 17/4.47)

4.48 Providing and laying cement concrete using 20 mm and down size granite
jelly of ready mixed concrete (RMC) for R.C.C. works laid in 15 cms thick
layers and well compacted vibrating, curing, finishing with necessary
cement mortar, with all lead and lifts etc., complete (exclusive of cost of
steel and fabrication charges.) (P.W.D. SR 2009-10/P.No. 17/4.48)

4.48.1 Ready mixed Cement concrete nomional mix 1:1.5:3 for raft foundation,
column footing, main and secondary beams. (P.W.D. SR 2009-10/P.No. Cum 4150.00
17/4.48.1)

4.49 Providing and laying cement concrete using 20 mm and down size granite
jelly of ready mixed concrete for R.C.C. works laid in 15 cms thick layers
and well compacted including vibrating, curing including smooth finish in
CM 1:3, with all lead and lift etc., complete (exclusive of cost of steel and
fabrication charges.) (P.W.D. SR 2009-10/P.No. 17/4.49)

4.49.1 Ready mixed Cement concrete for Beams, Staircase and Roof with
Cum 4130.00
nominal mix1:1.5:3 (P.W.D. SR 2009-10/P.No. 17/4.49.1)

4.49.2 Ready mixed Cement concrete for Beams, Staircase and Roof with
Cum 4500.00
mominal mix 1:1:2 (P.W.D. SR 2009-10/P.No. 17/4.49.2)

4.50 KSRB 4.7 Scaffolding for stone masionry as in sl no. 4.43 converted to
Cum. (P.W.D. SR 2009-10/P.No. 17/4.50) Cum 119.00

4.51 KSRB 4.7 Scaffolding for stone masionry work as in sr no. 4.43 converted
to Sqm. (P.W.D. SR 2009-10/P.No. 17/4.51) Sqm 54.00

4.52 Providing and mixing synthetic fibers 100% vigin triangular monofillament
polyester fibers, 12mm in cut length for use as secondary fiber
reinforcement in concrete works. application per cubic meter shall be 125
grams per bag of cement or 0.25% by weight of cement. (P.W.D. SR 2009-
10/P.No. 17/4.52)

4.52.1 Providing and mixing synthetic fibers 100% vigin triangular monofillament
polyester fibers, 12mm in cut length for use as secondary fiber
reinforcement in concrete works. application per cubic meter shall be 125 Cum 270.00
grams per bag of cement or 0.25% by weight of cement for 1:2:4 concrete.
(P.W.D. SR 2009-10/P.No. 17/4.52.1)

4.52.2 Providing and mixing synthetic fibers 100% vigin triangular monofillament
polyester fibers, 12mm in cut length for use as secondary fiber
reinforcement in concrete works. application per cubic meter shall be 125
grams per bag of cement or 0.25% by weight of cement for 1:1.5:3 Cum 348.00
concrete. (P.W.D. SR 2009-10/P.No. 17/4.52.2)

4.53 Providing and mixing synthetic fibres 100% virgin triangular monofilament
polyester fibres, 12mm in cut length for use as secondary fibre
reinforcement in concrete works. Application per cubic meter shall be 125 Kgs 336.00
grams per bag of cement or 0.25% by weight of cement. (P.W.D. SR 2009-
10/P.No. 17/4.53)
4.54 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materias, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. If should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surface. Application per cubic meter Kgs 1200.00
shall be 0.9 kg 1.8 kg per cum in concrete, fibermesh stealth micro blocker
shall confirm to ASTM C-1116 type 111 4.1.3. (P.W.D. SR 2009-10/P.No.
17/4.54)

4.55 Providing and casting reined cement concrete racks with granite or trap
jelly 12mm and down size 1:11/2:3 proportion 5cms thick and below with
reinforcements pf 6mm dia MS bars at 15 cms. Centre to centre for main
reinforcement and at 30cms centre to centre for distribution including
supports wherever neccessary with burnt brick in CM 1:8 and plastered Sqm 465.00
with CM 1:4 or composite mortar 1:6 including centering, form work, curing
etc., complete (inclusive of cost of steel and fabrication charges.) (P.W.D.
SR 2009-10/P.No.18/4.55)

4.56 Providing RCC loft (atta) 7.5cms thick with cement concrete 1:1.5:3 using
clean granite or trap jelly of 20mm and down size with necessary
reinforcements at 20cms centre to centre as per design including form
work, centering, curing, finishing the exposed faces with cement morter Sqm 480.00
(1:3) etc., complete (exclusive of cost of steel and fabrication charges.)
(P.W.D.SR 2009-10/P.No.18/4.56)

4.57 Providing and fixing RCC slabs 5cms thick for wall shelves with 12mm and
down size jelly cement concrete 1:1.5:3 including CM 1:3 plaster finishing,
curing etc., complete (excluding the cost of steel and fabrication charges.) Sqm 435.00
P.W.D SR 2009-10/P.No.18/4.57

4.58 Providing RCC 1:1.5:3 using granite metal 20mm and down size for
7.5cms thick solid parapet or perforated as per design, specification and
directions. (exclusive of cost of steel and fabrication charges ) including
necessary Centering, form work and finishing smooth with CM (1:3) etc.,
complete. (P.W.D SR 2009-10/ P.No. 18/4.58)

4.58.1 Providing RCC 1:1.5:3 using granite metal 20mm and down size for
7.5cms thick solid parapet or perforated as per design, specification and
directions. (exclusive of cost of steel and fabrication charges ) including
necessary Centering, form work and finishing smooth with CM (1:3) etc., Sqm 490.00
complete. 7.5cms thick (P.W.D SR 2009-10/ P.No. 18/4.58.1)

4.58.2 Providing RCC 1:1.5:3 using granite metal 20mm and down size for
7.5cms thick solid parapet or perforated as per design, specification and
directions. (exclusive of cost of steel and fabrication charges ) including
necessary Centering, form work and finishing smooth with CM (1:3) etc., Sqm 635.00
complete. 10cms thick (P.W.D SR 2009-10/ P.No. 18/4.58.2)

5.0 STONE WORK


5.1 KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble stone
masonry in foundation with mud mortar (uncoursed), bond stones at two
m. apart in each course including cost of materials, labour, curing Cum 1000.00
complete as per specifications. KBS 5.1.12 (PWD SR 2009-
10/P.No.21/5.1)

5.2 KSRB 5-1.2 : Providing and constructing granite / trap / basalt rubble stone
masonry in foundation with cement mortar 1:8 (uncoursed), bond
stones at two m. apart in each course including cost of materials, labour, Cum 1650.00
curing complete as per specifications. KBS 5.1.12 (PWD SR 2009-
10/P.No.21/5.2)

5.3 KSRB 5-1.3 : Providing and constructing granite / trap / basalt rubble stone
masonry in foundation with cement mortar 1:6 (uncoursed), bond stones at
two m. apart in each course including cost of materials, labour, curing Cum 1770.00
complete as per specifications. KBS 5.1.12 (PWD SR 2009-
10/P.No.21/5.3)

5.4 KSRB 5-2.1 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with mud mortar, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart in each
Cum 1650.00
course including cost of materials, labour, curing complete as per
specifications. KBS 5.1.12 (PWD SR 2009-10/P.No.21/5.4)

5.5 KSRB 5-2.2 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with cement mortar 1:8, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart i each Cum 2200.00
course indluing cost of materials, labour, curing complete as per
specifications. KBS 5.1.13 (PWD SR 2009-10/P.No.21/5.5)

5.6 KSRB 5-2.3 : Providing and constructing granite / trap / basalt size stone
masonry in foundation cement mortar 1:6, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart i each Cum 2370.00
course indluing cost of materials, labour, curing complete as per
specifications. KBS 5.1.13 (PWD SR 2009-10/P.No.21/5.6)

5.7 KSRB 5-3.1 : Providing and constructing granite / trap / basalt size stone
masonry in basement with mud mortar, edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each
course including cost of materials, labour, curing complete as per Cum 2120.00
specifications. KBS 5.1.13 (PWD SR 2009-10/P.No.21/5.7)

5.8 KSRB 5-3.2 : Providing and constructing granite / trap / basalt size stone
masonry in basement with cement mortar 1:8, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, curing complete as per Cum 2670.00
specifications. KBS 5.1.13 (PWD SR 2009-10/P.No.21/5.8)

5.9 KSRB 5-3.3 : Providing and constructing granite / trap / basalt size stone
masonry in basement with cement mortar 1:6, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, curing complete as per Cum 2770.00
specifications. KBS 5.1.13 (PWD SR 2009-10/P.No.21/5.9)
5.10 KSRB 5-4.1 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with mud mortar, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 2250.00
complete as per specifications. KBS 5.1.13 (PWD SR 2009-
10/P.No.21/5.10)

5.11 KSRB 5-4.2 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:8, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 2800.00
complete as per specifications. KBS 5.1.13 (PWD SR 2009-
10/P.No.22/5.11)

5.12 KSRB 5-4.3 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:6, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 2900.00
complete as per specifications. KBS 5.1.13 (PWD SR 2009-
10/P.No.22/5.12)

5.13 KSRB 5-4.4 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:4, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 3130.00
complete as per specifications. KBS 5.1.13 (PWD SR 2009-
10/P.No.22/5.13)

5.14 KSRB 5-5 :Extra lift charges for size stone masonry above ground floor for
Cum 104.00
every additinal floor. KBS 5.1.13 (PWD SR 2009-10/P.No.22/5.14)

5.15 KSRB 5-6 :Extra for constructing stone masonry square or rectngular
pillars complete as per specifications. KBS 5.1.13 (PWD SR 2009- Cum 160.00
10/P.No.22/5.15)

5.16 KSRB 5-7 :Extra for constructing masonry in circular pillars including cost
of extra mateirals and labour compete as per specifications. KBS 5.1.13 Cum 375.00
(PWD SR 2009-10/P.No.22/5.16)

5.17 KSRB 5-8.1 : Providing one line dressing to granite stone slab / granite
stone masonry as per specifications. KBS 5.1.13(PWD SR 2009- Sqm 290.00
10/P.No.22/5.17)

5.18 KSRB 5-8.2 : Providing two line dressing to granite stone slab / granite
stone masonry as per specifications. KBS 5.1.13(PWD SR 2009- Sqm 485.00
10/P.No.22/5.18)

5.19 KSRB 5-8.3 : Providing three line dressing to granite stone slab / granite
stone masonry as per specifications. KBS 5.1.13(PWD SR 2009- Sqm 680.00
10/P.No.22/5.19)

5.20 KSRB 5-8.4 : Providing pulmane finish only on three line dressed surface
as per specifications. KBS 5.1.13(PWD SR 2009-10/P.No.22/5.20) Sqm 190.00

5.21 KSRB 5-8.5 : Providing quoin dressing to stone masonry and stone slabs,
two line 5 cms wide on each face as per specifications. (measurement
including mortar joints) KBS 5.1.13(PWD SR 2009-10/P.No.22/5.21) m 48.00
5.22 KSRB 5-9 : Providing chamfering edges to stone slab 2.5 cms wide as per
specifications. (only chamfered length shall be recorded) KBS 5.1.13) m 18.00
(PWD SR 2009-10/P.No.22/5.22)

5.23 KSRB 5-10 : Providing hammer dressing to size stones as per


No 3.40
specifications KBS 5.1.13.3 (PWD SR 2009-10/P.No. 22/5.23)

5.24 KSRB 5-11 : Providing and constructing load bearing wall with cement
concrete cavities blocks (hollow blocks) of proportion 1:5:3 blocks of
size 40 x 20 x 20 cms. (1 x b x h) strength not less than 50kg. per sqm
with cement mortar 1:4 conforming to I.S. 2185 of 1967 having not less
than 40mm. shell thickness with two or more large cavities and having Sqm 495.00
solid material between including cost of materials, labour charges,
scaffolding, curing complete as per specification. KBS 5.4 (PWD SR 2009-
10/P.No. 22/5.24)

5.25 KSRB 5-12 : Providing and constructing load bearing wall with cement
concrete cavities blocks (hollow blocks) of proportion 1:5:3 blocks of size
40 x 20 x 20 cms. (1 x b x h) strength not less than 35kg. per sqm with
cement mortar 1:4 conforming to I.S. 2185 of 1965 having not less than
40mm. shell thickness with two or more large cavities and having solid Sqm 490.00
material between including cost of materials, labour charges, scaffolding,
curing complete as per specification. (PWD SR 2009-10/P.No. 23/5.25)

5.26 KSRB 5-13 : Providing and constructing non-load bearing wall with cement
concrete cavities blocks (hollow blocks) of proportion 1:5:3 blocks of size
40 x 10 x 20 cms. (1 x b x h) strength not less than 35kg. per sqm with
cement mortar 1:4 conforming to I.S. 2185 of 1967 having not less than
40mm. shell thickness 50% of total volume of block having two large Sqm 425.00
cavities with 20mm. wall thickness in between including cost of mateirals,
labour charges, scaffolding, curing complete as per specification. (PWD
SR 2009-10/P.No. 23/5.26)

5.27 KSRB 5-14: Providing and constructing precast concrete solid blocks with
compressive strength not less than 35 kg/sqm with cement mortar 1:4
masonry )quoin, Jamb, closer blocks) with solid concrete blocks of size 40
x 20 x 20 cms. conforming to I.S. 2185 of 1965 in superstructure including Sqm 650.00
cost of materials, labour charges, scaffolding, curing complete as per
specification. (PWD SR 2009-10/P.No. 23/5.27)

5.28 KSRB 5-15 : Providing and constructing non-loab bearing wall with cement
concrete solid blocks with compressive strenght not less than 35 kg/sqm
with cement mortar 1:4 (Jamb, closer blocks) with blocks of size 40 x 10 x
20 cms. )lxbxh) conforming to I.S. 2185 of 1965 in superstructure including Sqm 440.00
cost of materials, labour charges, scaffolding, curing complete as per
specification. (PWD SR 2009-10/P.No. 23/5.28)

5.29 Providing and fixing Pre cast solid concrete kerb stones made out of CC
1:2:4 of size 450 x 200 x 400mm and finished with CM 1:3 plastering and
finishing cutting etc., complete.(PWD SR 2009-10/P.No. 23/5.29)

5.29.1 Providing and fixing Pre cast solid concrete kerb stones made out of CC
1:2:4 of size 450 x 200 x 400mm and finished with CM 1:3 plastering and
finishing cutting etc., complete.(PWD SR 2009-10/P.No. 23/5.29.1) No 269.00
5.29.2 Providing and fixing Pre cast solid concrete kerb stones made out of CC
1:2:4 of size 450 x 150 x 500mm and finished with CM 1:3 plastering and
finishing cutting etc., complete.(PWD SR 2009-10/P.No. 23/5.29.2) No 209.00

5.30 Providing and fixing pre cast solid cement concrete kerb stones made out
of C.C. 1:2:4 with top and bottom width 114 and 165mm respectively,
400mm high and 450mm in length finished with CM 1:3 plastering and
finishing cutting, including formwork, curing,including cost of all materials, No. 209.00
labour, hire charges of machinery, loading, unloadng lead and lift,
transportation etc., complete. (PWD SR 2009-10/P.No. 23/5.30)

5.31 Providing granite slabs of selected quality roughly dressed and fixed in
cement mortar (1:6) including fixing curing etc., complete.(PWD SR 2009-
10/P.No. 23/5.31)

5.31.1 Providing granite slabs of selected quality 7.5cms thick, roughly dressed
and fixed in cement mortar (1:6) including fixing curing etc., complete. Sqm 410.00
(PWD SR 2009-10/P.No. 23/5.31.1)

5.31.2 Providing granite slabs of selected quality 10cms thick, roughly dressed
and fixed in cement mortar (1:6) including fixing curing etc., complete. Sqm 480.00
(PWD SR 2009-10/P.No. 23/5.31.2)

5.32 Removing B.S. slab of drain and stacking (PWD SR 2009-10/P.No.


Sqm 33.00
23/5.32)

5.33 Refixing stone slabs of drains and pointing in C.M (1:3) (PWD SR 2009-
10/P.No. 23/5.33) Sqm 44.00

6.0 BRICK WORK (2009-10)


6.1 KSRB 6-1.1 : Providing and constructing burnt brick masonry with
approved quality of non modular bricks of standard size of class
designation 35 wtih mud mortar for basement and superstructure including
cost of materials, labour charges, scaffolding, curing complete as per Cum 2890.00
specifications. Specification No. KBS 6.2 (PWD SR 2009-10/P.No. 25/6.1)

6.2 KSRB 6-1.2 : Providing and constructing burnt brick masonry for basement
and superstructure with approved quality of non- modular bricks of
standard size of class designation 35 wtih cement mortar 1:8 including
cost of materials, labour charges, scaffolding, curing complete as per Cum 3390.00
specifications. Specification No. KBS 6.2 (PWD SR 2009-10/P.No. 25/6.2)

6.3 KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement
and superstructure with approved quality of non- modular bricks of
standard size of class designation 35 wtih cement mortar 1:6 including
cost of materials, labour charges, scaffolding, curing complete as per Cum 3480.00
specifications. Specification No. KBS 6.2 (PWD SR 2009-10/P.No. 25/6.3)

6.4 KSRB 6-2.1 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 (table moulded) wtih mud mortar for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 3020.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 25/6.4)
6.5 KSRB 6-2.2 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 (table moulded) wtih cement mortar 1:8 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 3560.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 25/6.5)

6.6 KSRB 6-2.3 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 (table moulded) wtih cement mortar 1:6 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 3660.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 25/6.6)

6.7 KSRB 6-2.4 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 wtih cement mortar 1:4 for basement and superstructure
including cost of materials, labour charges, scaffolding, curing complete as Cum 3850.00
per specifications. Specification No. KBS 6.2 (PWD SR 2009-10/P.No.
25/6.7)

6.8 KSRB 6-3.1 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 with cement mortar 1:8 for basement and
superstructure (Machine moulded Wirecut bricks) with cost of materials, Cum 5570.00
labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2 (PWD SR 2009-10/P.No. 25/6.8)

6.9 KSRB 6-3.2 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 wtih cement mortar 1:6 for basement and superstructure
(Machine moulded Wirecut bricks) with cost of materials, labour charges, Cum 5660.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2009-10/P.No. 25/6.9)

6.10 KSRB 6-3.3 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 wtih cement mortar 1:4 for basement and superstructure
(Machine moulded Wirecut bricks) with cost of materials, labour charges, Cum 5860.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2009-10/P.No. 25/6.10)

6.11 KSRB 6-3.4 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 wtih cement mortar 1:3 for basement and superstructure
(Machine moulded Wirecut bricks) with cost of materials, labour charges, Cum 6050.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2009-10/P.No. 25/6.11)

6.12 KSRB 6-4.1 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 35 wtih mud mortar for basement and superstructure Cum
with cost of materials, labour charges, scaffolding, curing complete as per
specifications. (PWD SR 2009-10/P.No. 25/6.12)
6.13 KSRB 6-4.2 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 35 wtih cement mortar 1:8 for basement and
superstructure with cost of materials, labour charges, scaffolding, curing Cum
complete as per specifications. Specification No. KBS 6.2 (PWD SR 2009-
10/P.No. 26/6.13)

6.14 KSRB 6-4.3 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation cement mortar 1:6 for basement and superstructure
with cost of materials, labour charges, scaffolding, curing complete as per Cum
specifications. Specification No. KBS 6.2 (PWD SR 2009-10/P.No.
26/6.14)

6.15 KSRB 6-5.1: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
50(table moulded) with mud mortar for basement and superstructure
including cost of materials, labour charges, scaffolding, curing complete as Cum
per specifications. Specification No. KBS 6.2 (PWD SR 2009-10/P.No.
26/6.15)

6.16 KSRB 6-5.2: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
50(table moulded) with cement mortar 1:8 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 26/6.16)

6.17 KSRB 6-5.3: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
50(table moulded) with cement mortar 1:6 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 26/6.17)

6.18 KSRB 6-5.4: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 50
(table moulded) with cement mortar 1:4 for basement and superstructure
including cost of materials, labour charges, scaffolding, curing complete as Cum
per specifications. (PWD SR 2009-10/P.No. 26/6.18)

6.19 KSRB 6-6.1: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
75 (Machine moulded Wirecut bricks) with cement mortar 1:8 for
basement and superstructure including cost of materials, labour Cum
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2009-10/P.No. 26/6.19)

6.20 KSRB 6-6.2: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 75
(Machine moulded Wirecut bricks) with cement mortar 1:6 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 26/6.20)
6.21 KSRB 6-6.3: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 75
(Machine moulded Wirecut bricks) with cement mortar 1:4 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 26/6.21)

6.22 KSRB 6-6.4: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 75
(Machine moulded Wirecut bricks) with cement mortar 1:3 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2009-10/P.No. 26/6.22)

6.23 KSRB 6-7.1 : Construction of partition wall 11.2 cms thick with non-
modular ground moulded burnt bricks of class designation 35 with cement
mortar 1:4 including Providing and fixing plaster mesh manufactured out of
hot dipped galvanised iron of nominal thickness 0.35mm 100mm. wide as
per I.S. 2212/1991 at 7.5 m c to c including cost of materials, labour Sqm 495.00
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2009-10/P.No.26/6.23)

6.24 KSRB 6-7.2 : Construction of partition wall 11.2 cms thick with non-
modular table moulded burnt bricks of class designation 50 with cement
mortar 1:4 including Providing and fixing plaster mesh manufactured out of
hot dipped galvanised iron of nominal thickness 0.35mm 100mm. wide as
Sqm 530.00
per I.S. 2212/1991 at 7.5 m c to c including cost of materials, labour
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2009-10/P.No.27/6.24)

6.25 KSRB 6-7.3 : Construction of partition wall 11.2 cms thick with non-
modular ground moulded burnt bricks of class designation 35 with cement
mortar 1:4 including cost of materials, labour charges, scaffolding, curing Sqm 465.00
complete as per specifications. KBS 6.2 (PWD SR 2009-10/P.No.27/6.25)

6.26 KSRB 6-7.4 : Construction of partition wall 11.2 cms thick with non-
modular table moulded burnt bricks of class designation 50 with cement
mortar 1:4 including cost of materials, labour charges, scaffolding, curing Sqm 490.00
complete as per specifications. Specification No. KBS 6.2 (PWD SR 2009-
10/P.No.27/6.26)

6.27 KSRB 6-8.1 : Construction of partition wall 10 cms thick with ground
moulded modular burnt bricks of class designation 35 with cement
mortar 1:4 including providing and fixing plaster mesh manufactured out
of hot dipped gelvanised iron of nominal thickness 0.35mm. 100 mm. wide
as per I.S. 2212/1991 at 7.5 m c to c including cost of materials, labour Sqm
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2009-10/P.No.27/6.27)

6.28 KSRB 6-8.2 : Construction of partition wall 10 cms thick with table moulded
modular burnt bricks of class designation 50 with cement mortar 1:4
including providing and fixing plaster mesh manufactured out of hot dipped
gelvanised iron of nominal thickness 0.35mm. 100 mm. wide as per I.S.
2212/1991 at 7.5 m c to c including cost of materials, labour charges, Sqm
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2009-10/P.No.27/6.28)
6.29 KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground
moulded modular burnt bricks of class designation 35 with cement mortar
1:4 including cost of materials, labour charges, scaffolding, curing Sqm
complete as per specifications. Specification No.KBS 6.2 (PWD SR 2009-
10/P.No.27/6.29)

6.30 KSRB 6-8.4 :Construction of partition wall 10 cms thick with table moulded
modular burnt bricks of class designation 50 with cement mortar 1:4
including cost of materials, labour charges, scaffolding, curing complete as Sqm
per specifications. Specification No. KBS 6.2 (PWD SR 2009-
10/P.No.27/6.30)

STEEL AND ALLUMINIUM WORK


7.1 KSRB 7.1 : Providing and fixing in position collapsible steel shutters with
single or double leaf with vertical channel 20mm x 10mm x 2mm braced
with flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron
sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt
and nuts, locking arrangements, stoppers, handles on both sides with Sqm 2960.00
7.5cms openings at 10 cms. c to c applying a priming coat of red lead
paint. Cost of materials, labour, HOM of machinery complete as per
specifications. size of gate 2.4m x 1.4m. Specification No. KBS 7.7/7.12
(PWD SR 2009-10/P.No.29/7.1)

7.2 KSRB 7.2 : Providing and fixing 1mm thick M.S. Sheet sliding shutters with
frame and diagonal braces of 40x40x6mm angle iron 3.15mm thick M.S
Gusset plates at junctions and corners, 25mm dia pulley, 40x40x6 mm
angles and T iron guide rail top and bottom respectively with handles,
stoppers and locking arrangements etc., including applying a priming coat
Sqm 2400.00
of red lead paint cost of materials, labour HOM of machinery complete as
per specifications. 1 Double leaf door of size 2.4m x 2.4m. Specification
No. KBS 7.8/7.12 (PWD SR 2009-10/P.No.29/7.2)

7.3 KSRB 7.3 : Providing and fixing 1mm thick M.S. Sheet garage door with
frame and diagonal braces of size 40x40x6 mm angle iron, 3.15mm thick
M.S. Gussel plates at the junctions and corners, with handles, stoppers
and locking arrangements etc., including applying a priming coat of red
lead paint cost of materials, labour HOM of machinery complete as per Sqm 1870.00
specifications. Double leaf door of size 2.4m x 2.4m. Specification No.
KBS 7.9/7.12 (PWD SR 2009-10/P.No.29/7.3)

7.4 KSRB 7.4 : Providing and fixing 1mm thick M.S. Sheet garage door with
frame and diagonal braces of size 40x40x6 mm angle iron, using M.S. flats
30x6 mm for diagonal braces and central cross pieces 3.15mm thick MS
Gusset plates at the junctions and corners, with handles, stoppers and
locking arrangements etc., including applying a priming coat of red lead Sqm 1560.00
paint cost of materials, labour, HOM of machinery complete as per
specifications. 1bouble leaf door of size 2.4m x 2.4m. Specification No.
KBS 7.9/7.12 (PWD SR 2009-10/P.No.29/7.4)
7.5 KSRB 7.5 : Providing and fixing pull and push type rolling shutters of
approved make out of 18 guage, 75mm wide cold rolled steel laths of
convex corrugation, with side guides and bottom rail, with interlocking
arrangments for steel laths by means of alternate clips, suspension shaft
with High tension coil type springs two numbers, mounted on specially
designed pipe shaft, with bracket plates, guide channels, ball bearing
arrangements, for inside & outside locking with push & pull operations Sqm 2850.00
complete including pulling hooks, 4Nos. handles with all fittings and
accessories, painted with a coat of red lead paint (without top cover) cost
of materials, labour, HOM of machinery complete as per specifications.
Shutter size 3m x 2.8m. Specification No. KBS 7.10/7.12 (PWD SR 2009-
10/P.No.29-30/7.5)

7.6 KSRB 7.6 : Providing and fixing top convers made out of 20 guage M.S.
Sheet over pull and push rolling shutters bent to shape including cost of
red lead primer coat of painting, materials, labour, HOM of machinery m 415.00
complete as per specifications. Specification No. KBS 7.10.6/7.12 (PWD
SR 2009-10/P.No.30/7.6)

7.7 KSRB 7.7 : Providing and fixing in position in cement concrete 1:3:6 steel
glazed windows and ventilators side hung/top hung fully openable as per
approved drawings using Z angles of 25x33x3mm, weighing 1.419 kg/m
both for outer and inner frames and central mullion section of size
25x46x3mm weighing 2.28 Kg/m duly providing T section 19x19x3mm
weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood
beading of required size, all steel sections should confirm to I.S. 7452 :
1990, 4nos, of holdfasts of approved size, section should be cut to length Sqm 2770.00
welded and electrically grinded subdividing frames of unit shall be
tenonned and revetted into the frames electrically. All the steel surface
shall be throughly cleaned free of rust and painted with one coat of anti-
corosive paint and finishing with two coats of ready mix paint of approved
colour and make including cost of materials, fixtures, labour, and HOM of
machinery complete as per specifications. Specification No. KBS
7.12.1/7.12.2/7.12.3/7.12 (PWD SR 2008-09/P.No.30/7.7)

7.8 KSRB 7.8 : Providing and fixing in position in cement concrete 1:3:6 steel
glazed windows and ventilators side hung/top hung 2/3 openable 1/3 fixed
as per approved drawings using Z angles of 25x33x3mm, weighing 1.419
kg/m both for outer and inner frames and central mullion section of size
25x46x3mm weighing 2.28 Kg/m all duly providing T section 19x19x3mm
weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood
beading of required size, all steel sections should confirm to I.S. 7452 :
1990, 4nos, of holdfasts of approved size, section should be cut to length
Sqm 2300.00
welded and grinded electrically subdividing frames of unit shall be
tenonned and revetted into the frames electrically. All the steel surface
shall be throughly cleaned free of rust and painted with one coat of anti-
corosive paint and finishing with two coats of ready mix paint of approved
colour and make including cost of materials, fixtures, labour, and HOM of
machinery complete as per specifications. (PWD SR 2008-09/P.No.30/7.8)

7.9 KSRB 7.9 : Providing and fixing M.S. grill work for windows and ventilators
weighing 21 kg/sqm using M.S. flats, or M.S. square rods, ro combination
of M.S. flats and square rods as per approved design, drawing including
cutting steel sections and welding the same to required pattern with a coat
of red lead primer, cost of materials, fixtures, labour and and HOM of Kgs 60.00
machinery complete as per specifications. Specification No. KBS 7.12.
(PWD SR 2009-10/P.No.30/7.9)
7.10 KSRB 7.10 : Providing and fixing in position anodized aluminium windows
and ventilators as per approved drawings with sliding shutters using
double track window frame section of size 61.85x31.75mm. with 1.2mm
thick, bottom section weight 0.659 kg/m, sides and top sections 1.3mm
thick weight 0.659 kg/m: and shutter comprising top and bottom section of
size 40mm x 18mm, 1.25mm thick 0.417 kg/m, shutter outer side 40mm x
18mm, 1.25mm thick weight 0.417 kg.m, shutter interlock section 40mm x
26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon
rollers with approved quality of fixtures such as aluminium handles tower
bolts etc., and providing and fixing 5.5mm. thick plain glass for shutters
fitted with rubber beading aluminium sections anodised 12 to 15 microns,
including cutting to required length, joints mitred subdividing the frame
tenonned and rivetted in the assembled frame stiffened with end clips at
corners angles etc., and fixed to the walls, lintels, floor beams/cills as the Sqm 2800.00
case may be with necessary steel screws, raul plugs, or teak wood gatties
including

cutting masonry or concrete and making good theoriginal surface using


cement mortar, aluminium sections pretreated for removal of any rust and
protection of further rust formation and coated with the greasy materials for
non-adhesion of mortar and any other sticky materials, (this coating should
be cleaned after installation) including cost of all materials, fixtures, labour
and HOM of machinery complete as per specifications. (PWD SR 2009-
10/P.No.31/7.10)

7.11 KSRB 7.10 : Providing and fixing in position anodized aluminium windows
and ventilators as per approved drawings with sliding shutters using
double track window frame section of size 92.00xx31.75mm. with 1.3mm
thick, bottom section weight 1.07 kg/m, sides and top sections 1.3mm thick
weight 0.933 kg/m: and shutter comprising top and bottom section of size
40mm x 18mm, 1.25mm thick 0.417 kg/m, shutter outer side 40mm x
18mm, 1.25mm thick weight 0.417 kg.m, shutter interlock section 40mm x
26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon
rollers with approved quality of fixtures such as aluminium handles tower
bolts etc., and providing and fixing 5.5mm. thick plain glass for shutters
fitted with rubber beading aluminium sections anodised 12 to 15 microns,
including cutting to required length, joints mitred subdividing the frame
tenonned and rivetted in the assembled frame stiffened with end clips at
corners angles etc., and fixed to the walls, lintels, floor beams/cills as the Sqm 2770.00
case may be with necessary steel screws, raul plugs, or teak wood gatties
including

cutting masonry or concrete and making good theoriginal surface using


cement mortar, aluminium sections pretreated for removal of any rust and
protection of further rust formation and coated with the greasy materials for
non-adhesion of mortar and any other sticky materials, (this coating should
be cleaned after installation) including cost of all materials, fixtures, labour
and HOM of machinery complete as per specifications. (PWD SR 2009-
10/P.No.31/7.10)
7.12 KSRB 7.12 : Providing and fixing in position anodized aluminium windows
and ventilators as per approved drawings with sliding shutters using four
track window frame of size 122.2x31.75mm. for bottom section 1.1mm
thick weight 1.205 kg/m, sides and top sections 1.2mm thick weight 1.093
kg/m: shutter section comprising top and bottom section of size 40mm x
18mm, wall thickness 1.25mm weight 0.417 kg/m, shutter side outer
40mm x 18mm, wall thickness 1.25mm weight 0.417 kg.m, shutter
interlock section 40mm x 26.7mm wall thickness 1.1mm thick, weight
0.469 kg/m. the shutters mounted on nylon rollers with approved quality of
fixtures such as aluminium handles tower bolts etc.; providing and fixing
5.5mm. thick plain glass for shutters fitted with rubber beadingaluminium
sections anodised 12 to 15 microns thick including cutting to required
length, joints mitred subdividing the
Sqm 2500.00

frame tenonned and rivetted in the assembled frame to be stiffened with


end clips for corners, angles etc., and fixed to the walls, lintels, floor
beams/cills as the case may be with necessary steel screws, raul plugs, or
teak wood gatties including cutting masonry or concrete and making good
the original surface using cement mortar, aluminium pretreated for removal
of any rust and coated with greasy materials for non-adhesion of mortar
and any other sticky materials, (this coating should be cleaned after
installation) including cost of all materials, fixtures, labour and HOM of
machinery complete as per specifications. (PWD SR 2009-
10/P.No.31/7.12)

7.13 KSRB 7.11 : Providing and fixing anodized aluminium casement windows
combination of foxed glazing at top fully openable windows using Z
sections of 33 mm, web thickness 4mm, weight 0.663 kg/m, central mullion
section 59 x 33mm with web thickness 3mm section weight 1.123kg/m the
shutters on aluminium hinges with aproved quality of fixtures such as
aluminium tower board, handles, stays etc., providing and fixing 5.5mm
plain glass for shutters fitted with glazed clips 19mm x 17.3mm x11mm. Sqm 3200.00
0.9mm thick and rubber beading aluminium sections anodized to 12 to 15
microns cutting to required length, joints metered subdividing the frame
tennoned and rivetted, assembled frame to be stiffened with end clips at
corner,

angles and fixed to wall, lintel beam, floorcill as the case may be with
nessesary screws, rawl plugs, cutting masonry or concrete and making
good the original surface aluminium easy materials for non -adherence of
mortar or any other sticky materials (coating removed after installation)
through the cleaned free from dust etc., including cost of mateirals,
fixtures, labour, and HOM masonry complete as per specifications.

(PWD SR 2009-10/P.No.32/7.13)
7.14 KSRB 7.14 : Providing, fabricating, assembling and fixing in position
anodized aluminium partitions using sections in combination of plain,
single grove and double grove as per requirements for the frames of
overall size 101.6mm x 44.45mm, 3.18mm. thick having section weight,
plain section 2.40kg/m, single grove section 2.541 kg/m and double grove
section 2.683kg/m and bottom member 114.3 mm x 44.45mm. 3.18mm.
thick weight 2.646 kg/m; aluminium louvers of size 77.6mm x 27.6mm
1.7mm. thick section weight 0.483 kg/m bottom portions provided with
12mm. thick prelaminated sheet both side of approved colour lamination
exterior grade aluminium sections of mat finish or glossy finish using
section, spacing of vertical member shall not exceed 0.6 m. c to c; sections
are cut to the required lengths, joints mitered and corners grinded
subdividing frames tennoned and rivetted to the frames, the assembled
frame should be stiffened with corner angles stripped and fixed with
screws, rawl plugs and teak wood gutties to RCC columns or masonry on
sides, RCC lintels or beams at top and floor at bottom, including cutting
chistling and making

Sqm 3590.00

good with cement mortar to match the surface providing and fixing bottom
panel filled with the materials to a height of 0.9m from floor level; and
5.5mm, thick plain glass for middle portion viz., 0.9m to 2.13m and top
panel with lower sections, the glass and panels fitted with glazing clips of
19mm x 17.3mm with thickness of 0.9mm weight 0.124 kg/m; aluminium
sections anodised 12 to 15 mirons, sections pretreated for removal of any
rust and prevention of further rust formation, and coated with greasy
materials for non- adherence of mortars or any other sticky materials;
vertical members embedded in the flooring by making suitable size holes
and fixing with cement mortar, with necessary opening for fixing of doors of
standard size (excluding cost of door opening) All the frame should be
throughly cleaned free from rust, scale or dirt including cost of materials,
fixtures, labour and HOM of machinery complete as per specifications.
(PWD SR 2009-10/P.No. 32/7.14)

7.15 KSRB 7.15 : Providing, fabricating, assembling and fixing in position


anodized aluminium partitions using aluminium sections of mat finish or
glassy finish in combination of plain grove, single grove and double grove
as per requirements for the frames of overall size 63.5mm x 38.1mm. with
thickness of 2mm. having section weight, plain section 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094 kg/m and double grove
thickness 1.9mm section weight 1.094kg/m and bottom member 114.3 mm
x 44.45mm. thickness 3.18mm. weight 2.646 kg/m; aluminium louvers
section of size 36.5mm x 34.93mm 1.45mm. thick section weight 0.429
kg/m bottom portions provided colour lamination exterior grade upto
0.9mheight, spacing of vertical membe not exceeding 0.6m c to c; sections
are cut to the required lengths, joints mitered to the frames; the assembled
frame stiffened with corner angles, stripped and fixed with screws, rawl
plugs and teak wood gutties to RCC columns on sides RCC lintels or
beams at top and floor at bottom, including cutting chistelling and making
good with cement mortar to match
Sqm 2300.00
Sqm 2300.00

the surface; providing and fixing 5.5mm. thick plain glass for middle portion
viz., 0.9m to 2.13m and top panel with louver sections; the glass and
panels fitted with glazing clips of 19mm x 17.3mm. of thickness 0.9mm.
weight 0.124kg/m, aluminium sections anodised 12 to 15 microns, sections
treated for removal fo any rust and prevention of further rust formation,
coated with greasy materials for non-adherence of mortars or any other
sticky materials; vertical members embedded in the flooring by making
suitable sized holes and fixing with cement mortar, with necessary opening
for fixing of door of standard size (excluding cost of door) all the frame
throughly cleaned, free from rust, scale or dirt including cost of mateirals,
fixtures, labour and HOM of machinery complete as per specifications.
(PWD SR 2009-10/ P.NO.33/7.15)

7.16 KSRB 7.15 : Providing, fabricating, assembling and fixing in position


anodized aluminium shutters to the existing dooe frame in the partition
using using 47.62 x 44.45mm section thickness 3.18mm, weight 1.505
kg/m for vertical frame; 47.62 x 44.45 thickness of 3mm, weight 1.42 kg/m
for top section, 49.91mm x 44.45mm with wall thickness 3mm, weight
1.495 kg/m for central rail; and114.3mm x, plain section 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094 kg/m and double grove Sqm 2920.00
thickness 1.9mm section weight 1.094kg/m and bottom member 114.3 mm
x 44.45mm. thickness 3.18mm. weight 2.646 kg/m for bottom rail;
aluminium sections anodized 12 to 15 microns and cut to lenght joint
metred and corners grinded, the bottom rail and top rail hinged or pivoted,
opening arrangements including providing and

fixing standard approved accessories, such as aluminium handles, tower


bolts, lock, pivots; hinges PVC or rubber gasket, 12mm prelaminated
sheets (Novopan) extetior grade of approved colour both sides same
colour for bottom panel of maximum height 0.90m and 5.5 mm thick plain
glass for top panel (Novopan) and glass fixed with glazed clips
19mmx11mm, 0.9mm thick, weight 0.124 kg/m. aluminium sections treated
for removal of any rust and prevention of further rust formation, and
coated with greasy materials for non-adherance of mortars or any other
stickly materials, including cost of materials, fixtures, labour and HOM of
machinery complete as per specification.(PWD SR 2009-10/P.No.
34/7.16)

7.17 KSRB 7.17 : Providing, fabricating, assembling and fixing in position


anodized aluminium doors using following aluminium mat finish, outer
frame plain section 101.6x44.45mm thickness 3.18mm, section weight
2.404 kg/m door shutters vertical section 44.62 x 44.45mm thickness
3.18mm, section weight 1.505 kg/m top section, 47.62 x 44.45mm
thickness 3.00mm, section weight 1.426 kg/m bottom section114.3x44.45
thickness 3.18mm,section weight 2.646kg/m door central section
49.91x45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips
19x17.3x11mm thickness 0.9mm section weight 0.124 kg/m; aluminium
sections anodized 12 to 15 microns cut to lenght joint metred corners
grinded, the shutters pivoted opening arrangement with heavy duty
aluminium alloy automatic door closures floor mounted, providing and
fixing standard approved accessories, such as aluminium handle for full
width or length, tower bolts, lock, pivots: PVC or rubber gasket with 5.5m. Sqm 4370.00
thick plain glass for top and bottom panel; aluminium sections treated for
removal of any rust and preventon of further rust formation, and coated
with greasy materials for non-adherance of mortars or any other sticky
materials; the

assembled frame fitted with the corner angles, strips and fitted with
screws, rawl plugs or teakwood gutties to RCC columns or masonry on
sides. beams and flooring in botton. including cutting, chistling and making
good with cement mortar to match the surface; all the frames throughly
cleaned free from rust, scale or dirt including cost of materials, fixtures,
labour and HOM of machinery complete as per specifications. (PWD SR
2009-10/P.No. 34/7.17)
7.18 Providing and fixing of Aluminium composite panel of approved make and
colour for wall cladding for straight Brick/RCC/Stone walls &
coloumns/beams with necessary aluminium frame works at required level
made out of 50x25x3mm 'C' section or equalent. The panel should consist
of 2.5mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminiumsheet making a total panel thickness of 3mm. The
surface coating on reverse sides would be in polyester paint. The system
shall be fixed using GI brackets, aluminium L cleats and stainless steel Sqm 4790.00
bolts and nuts complete with spring washer and cap nuts and all other
necessary accessories, sealing shall be done using weather sealant of
Dow Corning 789 with necessary rods etc., complete. (PWD SR 2009-
10/P.No. 34/7.18)

7.19 Providing and fixing of Aluminium composite panel of approved make and
colour for wall cladding for curved Brick/RCC/Stone walls &
coloumns/beams with necessary aluminium frame works at required level
made out of 50x25x3mm 'C' section or equalent. The panel should consist
of 2.5mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminium sheet making a total panel thickness of 3mm. The
surfaces will be finished with PVDF based coating on topsides and service
coating on reverse sides would be in polyester paint. The system shall be Sqm 4920.00
fixed using GI brackets, aluminium L cleats and stainless steel bolts and
nuts complete with spring washer and cap nuts and all other necessary
accessories, sealing shall be done using weather sealant of Dow Coring
789 with necessary rods etc., complete. (PWD SR 2009-10/P.No. 35/7.19)

7.20 Providing, Fabricating and fixing of stick type structural glazing using
Alluminium Extrusions of 63.5 mm x 58.00 mm x 2.25mm of 1.73 kgs/mtr
for vertical and Horizontal members and 63.5mm x 38.1 x 1.33mm of
0.759 kg/mtr, as outer frame with Electro Anodized Paint coated block
finishing, using 6mm thick imported glass reflective hard coated ocean
blue raw glass with all necessary accesories like ultra glass Silicon sealant
of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, Sqm 5185.00
6mm thick M.S angle 50mm x 150mm x 600 M.S Galvanized L Brackets,
structural sealent setting clocks, fasteners, wall connection etc., complete.
(PWD SR 2009-10/P.No. 35/7.20)

7.21 Providing fusion bonded epoxy coating not less than 175 microns
thickness and upto 300 microns to reinforcement of all diameters as per
IS: 13620-1993 including testing of coating at plant. The rate is inclusive of
cost on account of careful handling, PVC coated binding wire instead of GI
Binding wire, touch up material supplied by coating agency, repair work,
loading, unloading and straightening of bent rods etc., complete as per
specification and as directed by the Engineer in charge. (inclusive of all
taxes but excluding transportation charges)
(PWD SR 2009-10/P.No. 35/7.21)

7.21.1 Providing fusion bonded epoxy coating not less than 175 microns
thickness and upto 300 microns to reinforcement of all diameters as per
IS: 13620-1993 including testing of coating at plant. The rate is inclusive of
cost on account of careful handling, PVC coated binding wire instead of GI
Binding wire, touch up material supplied by coating agency, repair work, Tonne 10800.00
loading, unloading and straightening of bent rods etc., complete as per
specification and as directed by the Engineer in charge. (inclusive of all
taxes but excluding transportation charges) For 10mm to 16mm dia bars
(PWD SR 2009-10/P.No. 35/7.21.1)
7.21.2 Providing fusion bonded epoxy coating not less than 175 microns
thickness and upto 300 microns to reinforcement of all diameters as per
IS: 13620-1993 including testing of coating at plant. The rate is inclusive of
cost on account of careful handling, PVC coated binding wire instead of GI
Binding wire, touch up material supplied by coating agency, repair work, Tonne 7700.00
loading, unloading and straightening of bent rods etc., complete as per
specification and as directed by the Engineer in charge. (inclusive of all
taxes but excluding transportation charges) For 20mm to 32mm dia bars
(PWD SR 2009-10/P.No. 35/7.21.2)

7.22 Providing, fabricating, assembling and fixing in position anodized


aluminium partition using 101.60mm x 44.45mm x 3.18mm aluminium,
mate finish or glossy finish, anodized sections combination of plain, single
groove and double groove members should not exceed 0.60 mc/c and
bottom member of required lengths, joints mitred and corner grinded sub
dividing assembled frame should be stiffened with corner angles. Stripped
and fixed with screws rawl plug and teakwood guttas to RCC column or at
bottom; including cutting chistelling and making good with cement mortar
to match the surface. Providing and fixing 12mm. thick prelaminated sheet
(Ecoboard - exterior grade) of approved colour for bottom panel of
maximum height 0.9m, and 5.50 mm thick plain or pin headed glass for
Sqm 2530.00
middle panel and top panel with glazing clips of 19.05mm x 17.30mm x
1.00mm. All the aluminium sections used should be treated for removal of
any rust and prevention of further rust formation and coated with materials:
The vertical members should be embedded in the flooring by making
suitable size holes and fixing with cement mortar. All the frame should be
thoroughly cleaned free

from rust, scale or dirt. work should be carried out as per direction of
engineer-in-charge of the work with all lead and lift as per chief Architect's
drawing etc., complete ti a degree of perfection. (PWD SR 2009-10/P.No.
35-36/7.22)

7.23 Providing and fixing door frame with or without ventilator made out of cold
rolled steel section of thickness 1.25mm formed into section of 60mm x
105mm welded to form a rectangular door conforming to IS 513-1973 and
phosphated and painted and with one coat of red oxide primer, two coat of
approved enamel paints the frame work with 4nos. of hold fast of size
200x25x4mm fixed in cement concrete 1:3:6 of 20mm down size jelly and
4nos.of ISI marked hinges 125mm long welded to the frame and fixed with
shutter made out of Honne wood styles and rails of 30mm thick with Sqm 1925.00
panels of 12mm thcik 'Ecoboard' Plain Particle Board of exterior grade
conforming to IS-3087 excluding the cost of fixtures but including labour
charges for fixing of fixtures. The hollow portion of the frame to be filled
with C.C. 1:2:4 of 20mm down size jelly. (PWD SR 2009-10/P.No.
36/7.23)

7.24 Providing and fixing cold rolld prepainted steel windows of IS Standards,
made out of 0.30 mm thick deep drawing quality galvanised on both sides
120 gms/Sq.mtr. Primer coat upto 5 microns with thermosetting epoxy
resin and finish painted with a polyester based paint 20 microns thick. The
size of profiles is approximately 46 x 52 mm for external frames, 46 x 46
mm section for shutters, 46 x 70 mm section for centre mullion/transom
and 18 x 31 mm section is for fixing glasses. The section should be cut to
length joint mitred and assembling by means of conrner brackets made out
of cold rolled cold annealed strips of 1.20 mm thick duly galvanised and
fixed with nickle plated self taping fixtures like handles made out of glass Sqm
filled nylone and hinges made out of CRCA powder coated. 4 mm thick
glass should be fixed with EPDM gaskets. Guard bars fabricated out of 10
mm square bright bars shall be fixed horizontally at 125 mm /C by rivetting
to the external frame. The above frames are fixed to the concrete/masonry
walls by means of self expanding screws.(PWD SR 2009-10/P.No.
36/7.24)
7.24.1 a)Providing and fixing cold rolld prepainted steel windows of IS Standards,
made out of 0.30 mm thick deep drawing quality galvanised on both sides
120 gms/Sq.mtr. Primer coat upto 5 microns with thermosetting epoxy
resin and finish painted with a polyester based paint 20 microns thick. The
size of profiles is approximately 46 x 52 mm for external frames, 46 x 46
mm section for shutters, 46 x 70 mm section for centre mullion/transom
and 18 x 31 mm section is for fixing glasses. The section should be cut to
length joint mitred and assembling by means of conrner brackets made out
of cold rolled cold annealed strips of 1.20 mm thick duly galvanised and
fixed with nickle plated self taping fixtures like handles made out of glass Sqm
filled nylone and hinges made out of CRCA powder coated. 4 mm float
glass without guard bars. Guard bars fabricated out of 10 mm square
bright bars shall be fixed horizontally at 125 mm /C by rivetting to the
external frame. The above frames are fixed to the concrete/masonry walls
by means of self expanding screws.(PWD SR 2008-09/P.No. 36/7.24.1)

7.24.2 b) Providing and fixing cold rolld prepainted steel windows of IS


Standards, made out of 0.30 mm thick deep drawing quality galvanised on
both sides 120 gms/Sq.mtr. Primer coat upto 5 microns with thermosetting
epoxy resin and finish painted with a polyester based paint 20 microns
thick. The size of profiles is approximately 46 x 52 mm for external frames,
46 x 46 mm section for shutters, 46 x 70 mm section for centre
mullion/transom and 18 x 31 mm section is for fixing glasses. The section
should be cut to length joint mitred and assembling by means of conrner
brackets made out of cold rolled cold annealed strips of 1.20 mm thick duly
galvanised and fixed with nickle plated self taping fixtures like handles Sqm
made out of glass filled nylone and hinges made out of CRCA powder
coated. 4 mm tinted glass without guard bars. Guard bars fabricated out of
10 mm square bright bars shall be fixed horizontally at 125 mm /C by
rivetting to the external frame. The above frames are fixed to the
concrete/masonry walls by means of self expanding screws.(PWD SR
2009-10/P.No. 36/7.24.2.)

7.24.3 c) Providing and fixing cold rolld prepainted steel windows of IS


Standards, made out of 0.30 mm thick deep drawing quality galvanised on
both sides 120 gms/Sq.mtr. Primer coat upto 5 microns with thermosetting
epoxy resin and finish painted with a polyester based paint 20 microns
thick. The size of profiles is approximately 46 x 52 mm for external frames,
46 x 46 mm section for shutters, 46 x 70 mm section for centre
mullion/transom and 18 x 31 mm section is for fixing glasses. The section
should be cut to length joint mitred and assembling by means of conrner
brackets made out of cold rolled cold annealed strips of 1.20 mm thick duly
galvanised and fixed with nickle plated self taping fixtures like handles Sqm 3600.00
made out of glass filled nylone and hinges made out of CRCA powder
coated. 4 mm float glass & with guard bars. Guard bars fabricated out of
10 mm square bright bars shall be fixed horizontally at 125 mm /C by
rivetting to the external frame. The above frames are fixed to the
concrete/masonry walls by means of self expanding screws.(PWD SR
2008-09/P.No. 36/7.24.3)
7.24.4 d) Providing and fixing cold rolld prepainted steel windows of IS
Standards, made out of 0.30 mm thick deep drawing quality galvanised on
both sides 120 gms/Sq.mtr. Primer coat upto 5 microns with thermosetting
epoxy resin and finish painted with a polyester based paint 20 microns
thick. The size of profiles is approximately 46 x 52 mm for external frames,
46 x 46 mm section for shutters, 46 x 70 mm section for centre
mullion/transom and 18 x 31 mm section is for fixing glasses. The section
should be cut to length joint mitred and assembling by means of conrner
brackets made out of cold rolled cold annealed strips of 1.20 mm thick duly
galvanised and fixed with nickle plated self taping fixtures like handles Sqm 3800.00
made out of glass filled nylone and hinges made out of CRCA powder
coated. 4 mm tinted glass with guard bars. Guard bars fabricated out of 10
mm square bright bars shall be fixed horizontally at 125 mm /C by rivetting
to the external frame. The above frames are fixed to the concrete/masonry
walls by means of self expanding screws.(PWD SR 2008-09/P.No.
36/7.24.4)

7.25 Providing and fixing cold rolled prepainted steel partitions of IS standards,
made out of 0.6mm of deep drawing quality galvanised on both sides
120gms/Sq.mtr. Primer coated upto 5 microness with thermosetting epoxy
resin and finish painted with a polyester based paint 20 micrones thick.
The size of profiles is 46 x 52mm for external frame, section for mullion or
transom is of size 46 x 70mm and section for fixing glass/ board is of 18 x
31mm. The section should be cut to length joint mitredc and assembling by
means of corner brackets made out of cold rolled cold annealed strips of Sqm 2420.00
1.2mm thick duly galvanised and fixed with nickle plated self taping
screws. 5mm thiock glss should be fixed with EPDM gaskets. 10mm thick
prelaminated particle board shll be fixed with the help of the clipping bead.
The above frames are fixed to the concrete/ masory walls and floors by
means of self expanding screws.(PWD SR 2009-10/ P.No.36-37/7.25)

7.26 Supplying and fixing pressed steel door frames size 125 x 65mm
manufactured from 1.25mm thick carbon steel or imported steel strips with
mitred joints of 900 for door 'opening and shutters made out of seasoned
Honne wood, styles of 300mm, thick with lock rail of 160mm, width, top
and side rails of 100mm. width and bottom rails of 250mm width and panel
filling with 12mm thick particle board of exterior grade bonded with phenol
formal heat resistant guaranteed against shrinkage, warpage and such
other defects for a period of 3 years. This shall be as per approved
drawings, specification and direction including cost of conveyance, Sqm 3058.00
manufacturing, painting with enamal paint 2 coats over primer coat, cost of
labour for all items of work, machinary, equipment and all other incidental
charges with all lead, lift, loading and unloading etc., complete. The Hollow
portion of the frame to be filled with cement concrete 1:2:4 (PWD SR
2009-10/ P.No.37/7.26)
7.27 Supplying and fixing pressed steel window frame of size 100 x 50mm
manufactured from 1.25 mm thick carbon stel or imported steel strips with
neat mitred joints at 900 degree for window opening and shall be suitable
to fix M.S. grills as per design and drawings using 12 mm dia rods at 100
mm Centre to Centre horizontally and two members of M.S flates of 6mm x
40 mm size at 150 mm apart, welded into a frame of 6 mm x 40 mm size
M.S. flates with 16mm size lugs, and 8 Nos.of 100mm size hinges, 4 Nos
of Butt Stay pins and 4 Nos. Tower bolts and shutters half panalled and
half glazed with shutters made out of seasoned honne wood, styles of 30
mm thick and 100mm width and rails of 30mm thick and 100mm width and
using 4mm thick pin headed glass and panel, fillling with 12mm thick
particle board of exteior grade with phenol formaldehyde resinand the Sqm 3322.00
shutter shall be rot proof vermin proof, heat resistant guranteed aginst
shrinkage, wrapage and such other defects for a period of 3 years.

This shall be as per approved drawing, specification and direction


including cost of conveyance, manufacturing painting with 2 coats enamal
paint over one coat of primer, cost of labour for all items of work,
machinary, equipment and all other incidental charges with all lead, lift
loading unloading etc., complete. The Hollow portion of the frame to be
filled with cement concrete 1:2:4. (PWD SR 2008-09/ P.No. 37/7.27

ROOFING
8.1 KSRB 8.1 : Providing and fixing in position stone slab roofing 10 to 12 cms
thick laid to line and level over wooden rafters or RCC battens, pointing
exposed joints with cement mortar 1:4 including cost of materials, labour,
curing complete as per specifications. (wooden rafters and RCC batters to Sqm 520.00
be paid seperately) (PWD SR 2009-10/P.No. 40/8.1)

8.2 KSRB 8.2 : Providing and fixing in position black cuddapah slab /
Shahabad Slab/Thandur blue slab 4 cms thick for roofing laid to line and
level over wooden rafters or RCC battens pointing exposed joints with
cement mortar 1:4 including cost of materials, labour, curing complete as
Sqm 350.00
per specifications. (Wooden rafters and RCC battens to be paid
seperately) (PWD SR 2009-10/P.No. 40/8.2)

8.3 KSRB 8.3-1 : Providing and laying to required line and slope roofing with
corrugated asbestos cement sheet 6mm, thick fixed with galvanised iron J
or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over
the existing purlins, rafters and trusses including cost of materials, labour, Sqm 320.00
complete as per specification, Specification No. KBS 8.5 (PWD SR 2009-
10/P.No. 40/8.3)

8.4 KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 (1 cement
: 15 cinderof 12.5mm nominal gauge) on terraced roof of sunken slabs,
laid to slope compacting, including cost of materials, labour, curing cum 1280.00
complete as per specification, (PWD SR 2009-10/P.No. 40/8.4)

8.5 KSRB 8.6-1 : Providing and fixing on wall surface cast iron rain down
water pipes 75mm dia including filling the joints with spunyarn soaked in
neat cement slurry 1:2 with necessary specials like shoes, bends and
offsets fixed with iron clamps, wall plugs, screws, including cost of m 675.00
materials, labour, complete as per specification, (PWD SR 2009-10/P.No.
40/8.5)
8.6 KSRB 8.3-2 : Providing and laying to required line and slope roofing with
semi-corrugated (Trafford) asbestos cement sheet 6mm, thick fixed with
galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and
bitumen washers over the existing purlins, rafters and trusses including Sqm 262.00
cost of materials, labour, complete as per specification, (PWD SR 2009-
10/P.No. 40/8.6)

8.7 KSRB 8.3-3 : Extra for A.C Sheet corrugated / semi-corrugated sheet
roofing with vertical sheeting to a pitch exceeding 60 degrees (PWD SR Sqm 5.20
2009-10/P.No. 40/8.7)

8.8 KSRB 8.3-4 : Providing and fixing ridges, hips with asbestos cement sheet
rooting with G.I. J or L hooks, bolts and nuts 8mm. dia G.I. Plain and
bitumen washers, serrated or plain wings, adjustable ridges, including cost m 250.00
of materials, labour, complete as per specification, (PWD SR 2009-
10/P.No. 40/8.8)

8.9 KSRB 8.3-5 : Providing and fixing northlight adjustable ridges, hips with
asbestos cement sheet rooting with G.I. J or L hooks, bolts and nuts 8mm.
dia G.I. Plain and bitumen washers, serrated or plain wings, adjustable m 225.00
ridges, including cost of materials, labour, complete as per specification,
(PWD SR 2009-10/P.No. 40/8.9)

8.10 KSRB 8.4-1 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips teak wood reepers of
size 50 x 25mm and pointed with cement mortar 1:4 over the existing
rafters including cost of materials, labour, complete as per specification. Sqm 760.00
Specification No. KBS 8.17 (PWD SR 2009-10/P.No. 41/8.10)

8.11 KSRB 8.4-2 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips nandi wood reepers of
size 50 x 25mm and pointed with cement mortar 1:4 over the existing
rafters including cost of materials, labour, complete as per specification. Sqm 625.00
Specification No. KBS 8.17 (PWD SR 2009-10 P.No. 41/8.11)

8.12 KSRB 8.4-3 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips jungle wood reepers of
size 50 x 25mm and pointed with cement mortar 1:4 over the existing
rafters including cost of materials, labour, complete as per specification. Sqm 555.00
Specification No. KBS 8.7 (PWD SR 2009-10/P.No. 41/8.12)

8.13 KSRB 8.6-3 : Providing and fixing on wall surface cast iron rain down
water pipes 100mm dia including filling the joints with spun yarn soaked in
neat cement slurry 1:2 with necessary specials like shoes, bends and
offsets fixed with iron clamps, wall plugs, screws, including cost of m 750.00
materials, labour, curing complete as per specification. Specification No.
KBS 8.25, 8.26 (PWD SR 2007-08/P.No. 41/8.13)

8.14 KSRB 8.6-3 : Providing and fixing on wall surface asbestos cement rain
down water pipes 75mm dia including filling the joints with spun yarn
soaked in neat cement slurry 1:2 with necessary specials like shoes,
bends and offsets fixed with iron clamps, wall plugs, screws, including cost m 295.00
of materials, labour, curing complete as per specification. Specification No.
KBS 8.26, 8.27 (PWD SR 2009-10/P.No. 41/8.14)
8.15 KSRB 8.6-4 : Providing and fixing on wall surface asbestos cement rain
down water pipes 100mm dia including filling the joints with spun yarn
soaked in neat cement slurry 1:2 with necessary specials like shoes,
bends and offsets fixed with iron clamps, wall plugs, screws, including cost m 330.00
of materials, labour, curing complete as per specification. Specification No.
KBS 8.26, 8.27(PWD SR 2009-10/P.No. 41/8.15)

8.16 KSRB 8.6-5 : Providing and fixing on wall surface 2.5kg/ sq.cm H.D.P.E.
rain down water pipes 90mm dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps, m 370.00
wall plugs, screws, including cost of materials, labour, curing complete as
per specification. (PWD SR 2009-10/P.No. 41/8.16)

8.17 KSRB 8.6-6 : Providing and fixing on wall surface 2.5kg/ sq.cm H.D.P.E.
rain down water pipes 110mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps,
wall plugs, screws, including cost of materials, labour, curing complete as m 405.00
per specification. (PWD SR 2009-10/P.No. 41/8.17)

8.18 KSRB 8.6-7 : Providing and fixing on wall surface 2.0 kg/ sq.cm H.D.P.E.
rain down water pipes 90 mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps,
wall plugs, screws, including cost of materials, labour, curing complete as m 395.00
per specification. (PWD SR 2009-10/P.No. 41/8.18)

8.19 KSRB 8.6-8 : Providing and fixing on wall surface 4.0kg/ sq.cm H.D.P.E.
rain down water pipes 110mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps,
wall plugs, screws, including cost of materials, labour, curing complete as m 450.00
per specification. (PWD SR 2009-10/P.No. 41/8.19)

8.20 KSRB 8.7-1 : Providing and fixing in position 10mm thick plaster of paris
(Gypsum anhydrous) for ceiling flat surface upto a height of 5m above floor
level over first class teakwood strips 25mm/6mm with 10mm gap in
between and reinforced with rabbit wire mesh fixed to wooden frames Sqm 1310.00
(frame work to be measured and paid for seperatly) including cost of
materials, labour, curing complete as per specification (PWD SR 2009-
10/P.No. 41/8.20)

8.21 KSRB 8.7-2 : Providing and fixing in position 10mm thick plaster of paris
(Gypsum anhydrous) for ceiling curved surface upto a height of 5m above
floor level over first class teakwood strips 25mm/6mm with 10mm gap in
between and reinforced with rabbit wire mesh fixed to wooden frames Sqm 1365.00
(frame work to be measured and paid for seperately) including cost of
materials, labour, curing complete as per specification (PWD SR 2009-
10/P.No. 41/8.21)

8.22 KSRB 8.7-3 : Extra over item No. 8.7-1 and 8.7-2 for any sunk or raised
moulded design plaster of paris (Gypsum anhydrous) ceiling (PWD SR Sqm 345.00
2009-10/P.No. 42/8.22)

8.23 KSRB 8.7-4 : Extra over item No. 8.7-1 and 8.7-2 for any providing plaster
of paris (Gypsum anhydrous) ceiling above 5 m height from floor level Sqm/m 50.00
(PWD SR 2009-10/P.No. 42/8.23)
8.24 KSRB 8.7-5 : Providing and fixing in position 12mm thick plaster of paris
(Gypsum anhydrous) for ceiling flat surface with ceiling tiles upto a height
of 5 m above floor level over wooden frames and rendered smooth with
plaster of paris (Frame work to be measured an paid for seperately) Sqm 660.00
including cost of materials, labour, curing complete as per specifications
(PWD SR 2007-08/P.No. 42/8.24)

8.25 KSRB 8.7-6 : Extra over item No. 8.7-5 for any providing plaster of paris
(Gypsum anhydrous) ceiling tiles above 5 m height from floor level (PWD Sqm/m 23.00
SR 2009-10/P.No. 42/8.25)

WOOD WORK
9.1 KSRB 9.1 : Labour for providing Teak wood wrought and putup for purlins,
common rafters and similar work including cost of labour, HOM of
machineries complete as per specifications. Specification No. KBS 9.4 cum 2050.00
(PWD SR 2009-10/P.No. 44/9.1)

9.2 KSRB 9-2.1: Providing Honne wood wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM
of machineries complete as per specifications. Specification No. KBS 9.27 cum 60400.00
(PWD SR 2009-10/P.No. 44/9.2)

9.3 KSRB 9-2.2: Providing Mathi/Nandi wood wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM
of machineries complete as per specifications. Specification No. KBS 9.27 cum 47400.00
(PWD SR 2009-10/P.No. 44/9.3)

9.4 KSRB 9-2.3 : Providing Sal wood wrought and putup for purlins, common
rafters and similar work including cost of materials, labour, HOM of
machineries complete as per specifications. Specification No. KBS 9.27 cum 38300.00
(PWD SR 2009-10/P.No. 44/9.4)

9.5 KSRB 9-2.4: Providing Jungle wood such as Nerale, Neem wrought and
putup for purlins, common rafters and similar work including cost of
materials, labour, HOM of machineries complete as per specifications. cum 31810.00
Specification No. KBS 9.27 (PWD SR 2009-10/P.No. 44/9.5)

9.6 KSRB 9-3.1: Providing Teak wood class-II frames for false ceiling,
partitions etc., main battens of size 50 x 12.5mm at 60 cms. c to c and
cross battons 38mm x 50mm at 60 cms. c to c sawn and putup including Sqm 2340.00
cost of mateirals, labour, complete as per specifications. Specification No.
KBS 9.28 (PWD SR 2009-10/P.No. 44/9.6)

9.7 KSRB 9-3.2 : Providing Honne wood frames for false ceiling, partitions
etc., main battens of size 50 x 12.5mm at 60 cms. c to c and cross battons
38mm x 50mm at 60 cms. c to c sawn and putup including cost of Sqm 1080.00
mateirals, labour, complete as per specifications. Specification No. KBS
9.28 (PWD SR 2009-10/P.No. 44/9.7)

9.8 KSRB 9-3.3 : Providing Matti or Nandi wood frames for false ceiling,
partitions etc., main battens of size 50 x 12.5mm at 60 cms. c to c and
cross battons 38mm x 50mm at 60 cms. c to c sawn and putup including Sqm 850.00
cost of mateirals, labour, complete as per specifications. Specification No.
KBS 9.28 (PWD SR 2009-10/P.No. 44/9.8)
9.9 KSRB 9-3.4 : Providing Sal wood frames for false ceiling, partitions etc.,
main battens of size 50 x 12.5mm at 60 cms. c to c and cross battons
38mm x 50mm at 60 cms. c to c sawn and putup including cost of Sqm 690.00
mateirals, labour, complete as per specifications. Specification No. KBS
9.28 (PWD SR 2009-10/P.No. 44/9.9)

9.10 KSRB 9-4.1: Providing Teak wood class-II frames of doors, windows,
clerestory windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves (excluding cost of cement
concrete and side clamps), but including cost of materials, labour, HOM of cum 130850.00
machineries complete as per specifications. Specification No. KBS 9.33
(PWD SR 2009-10/P.No. 44/9.10)

9.11 KSRB 9-4.2: Providing Honne wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps), but including cost of materials, labour, HOM of machineries cum 60800.00
complete as per specifications. Specification No. KBS 9.33 (PWD SR
2009-10/P.No. 44/9.11)

9.12 KSRB 9-4.3: Providing Matti/Nandi wood frames of doors, windows,


clerestory windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves (excluding cost of cement
concrete and side clamps), but including cost of materials, labour, HOM of cum 47800.00
machineries complete as per specifications. Specification No. KBS 9.33
(PWD SR 2009-10/P.No. 44/9.12)

9.13 KSRB 9-4.4: Providing Sal wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps), but including cost of materials, labour, HOM of machineries cum 38700.00
complete as per specifications. Specification No. KBS 9.33 (PWD SR
2009-10/P.No. 44/9.13)

9.14 KSRB 9-5.1: Providing and fixing in position fully panelled Teak wood
class -II shutters for doors, styles and rails of 40mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 5420.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 44/9.14)

9.15 KSRB 9-5.2: Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 40mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2760.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.15)

9.16 KSRB 9-5.3: Providing and fixing in position fully panelled Matti / Nandi
wood shutters for doors, styles and rails of 40mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2270.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.16)
9.17 KSRB 9-6.1: Providing and fixing in position fully panelled Teak wood
class-II shutters for doors, styles and rails of 35mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 5080.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.17)

9.18 KSRB 9-6.2: Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 35mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2600.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.18)

9.19 KSRB 9-6.3: Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors, styles and rails of 35mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2150.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.19)

9.20 KSRB 9-7.1: Providing and fixing in position fully panelled Teak wood
class-II shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 4730.00
machineries complete as per specifications. (excluding cost of fixtures)
(PWD SR 2009-10/P.No. 45/9.20)

9.21 KSRB 9-7.2: Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 30mm, thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2450.00
machineries complete as per specifications. (excluding cost of fixtures)
(PWD SR 2009-10/P.No. 45/9.21)

9.22 KSRB 9-7.3 : Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2030.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.22)

9.23 KSRB 9-8.1 : Providing and fixing in position fully panelled Teak wood
class-II shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 20mm thick including cost of materials, labour, HOM of Sqm 4390.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.23)

9.24 KSRB 9-8.2 : Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 30mm, thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 20mm thick including cost of materials, labour, HOM of Sqm 2290.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.24)
9.25 KSRB 9-8.3 : Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 20mm thick including cost of materials, labour, HOM of Sqm 1550.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2009-10/P.No. 45/9.25)

9.26 KSRB 9-9.1 : Providing and fixing in position Teak wood class-II half
panelled and half glazed shutters for doors, styles and rails of 40mm, thick
with bottom and lock rails 180mm wide top rail and styles 100mm wide as
per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4620.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42
(PWD SR 2009-10/P.No. 45/9.26)

9.27 KSRB 9-9.2 : Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 40mm, thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2440.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42
(PWD SR 2009-10/P.No. 45/9.27)

9.28 KSRB 9-10.1: Providing and fixing in position Teak wood class-II half
panelled and half glazed shutters for doors, styles and rails of 35mm, thick
with bottom and lock rails 180mm wide top rail and styles 100mm wide as
per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4280.00
including cost of materials, labour, HOM of machineries complete as per
specifications No. 9.34, 9.42 (excluding cost of fixtures) (PWD SR 2009-
10/P.No. 45/9.28)

9.29 KSRB 9-10.2: Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 35mm, thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2290.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2009-10/P.No. 45/9.29)

9.30 KSRB 9-11.1: Providing and fixing in position Teak wood class-II half
panelled and half glazed shutters for doors, styles and rails of 30mm, thick
with bottom and lock rails 180mm wide top rail and styles 100mm wide as
per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 3870.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2009-10/P.No. 46/9.30)

9.31 KSRB 9-11.2: Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 30mm, thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2100.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2009-10/P.No. 46/9.31)
9.32 KSRB 9-12.1: Providing and fixing in position Teak wood class-II half
panelled and half shutters for doors, styles and rails of 30mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 20mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 3660.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2009-10/P.No. 46/9.32)

9.33 KSRB 9-12.2 : Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 30mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 20mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2000.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2009-10/P.No. 46/9.33)

9.34 KSRB 9-13.1 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 2300.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.26.4 (PWD SR 2009-10/P.No.
46/9.34)

9.35 KSRB 9-13.2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side and balancing white colour on the
Sqm 2190.00
other including cost of materials, labour, HOM of machineries complete as
per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.26.4 (PWD SR 2009-10/P.No. 46/9.35)

9.36 KSRB 9-13.3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior gradeplain particle board including cost of
materials, labour, HOM of machineries complete as per specifications. Sqm 2040.00
(excluding cost of fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR
2009-10/P.No. 46/9.36)

9.37 KSRB 9-14.1 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 2100.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.26.4 (PWD SR 2009-10/P.No.
46/9.37)
9.38 KSRB 9-14.2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side and balancing white colour on the
other including cost of materials, labour, HOM of machineries complete as Sqm 2030.00
per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.26.4 (PWD SR 2009-10/P.No. 46/9.38)

9.39 KSRB 9-14.3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade plain particle board including cost of Sqm 1970.00
materials, labour, HOM of machineries complete as per specifications.
(excluding cost of fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR
2009-10/P.No. 46/9.39)

9.40 KSRB 9-15.1 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 1980.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR 2009-10/P.No.
47/9.40)

9.41 KSRB 9-15.2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side and balancing white colour on the
Sqm 1870.00
other including cost of materials, labour, HOM of machineries complete as
per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.26.3 (PWD SR 2009-10/P.No. 47/9.41)

9.42 KSRB 9-15.3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Plain particle board including cost of
materials, labour, HOM of machineries complete as per specifications. Sqm 1720.00
(excluding cost of fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR
2009-10/P.No. 47/9.42)

9.43 KSRB 9-16.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 35mm. thick, 75mm wide in
two halves with panels of 25mm thick including cost of materials, labour
Charges, HOM of machineries complete as per specifications. (excluding Sqm 5745.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2009-10/P.No.
47/9.43)

9.44 KSRB 9-16.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 35mm. thick, 75mm wide in
two halves with panels of 25mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 2900.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2009-10/P.No.
47/9.44)
9.45 KSRB 9-16.3 : Providing and fixing in position Matti / Nandi wood fully
panelled shutters for windows with styles and rails of 35mm. thick, 75mm
wide in two halves with panels of 25mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 2385.00
(excluding cost of fixtures) Specification No. KBS 9.34. (PWD SR 2009-
10/P.No. 47/9.45)

9.46 KSRB 9-16.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 35mm. thick, 75mm wide in
two halves with panels provided with NUWUD (MDF) of 25mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 2425.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2009-10/P.No. 47/9.46)

9.47 KSRB 9-17.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and styles and rails of 30mm. thick, 75mm
wide in two halves with panels of provided with NUWUD (MDF) of 20mm
thick including cost of materials, labour charges, HOM of machineries
Sqm 4880.00
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, (PWD SR 2009-10/P.No. 47/9.47)

9.48 KSRB 9-17.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 30mm. thick, 75mm wide in
two halves with panels of 20mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 2520.00
cost of fixtures) Specification No. KBS 9.34 (PWD SR 2009-10/P.No.
47/9.48)

9.49 KSRB 9-17.3 : Providing and fixing in position Matti / Nandi wood fully
panelled shutters for windows with styles and rails of 30mm, thick 75mm
wide in two halves with panels of 20mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 2080.00
(excluding cost of fixtures) Specification No. KBS 9.34 (PWD SR 2009-
10/P.No. 47/9.49)

9.50 KSRB 9-17.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 30mm, thick 75mm wide in
two halves with panels provided with NUWUD (MDF) of 18mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 2220.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2009-10/P.No. 48/9.50)

9.51 KSRB 9-18.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 25mm, thick 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 4445.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2009-10/P.No.
48/9.51)

9.52 KSRB 9-18.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 25mm, thick 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 2320.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2009-10/P.No.
48/9.52)
9.53 KSRB 9-18.3 : Providing and fixing in position Matti / Nandi wood fully
panelled shutters for windows with styles and rails of 25mm, thick 75mm
wide in two halves with panels of 20mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 1920.00
(excluding cost of fixtures) Specification No. KBS 9.34. (PWD SR 2009-
10/P.No. 48/9.53)

9.54 KSRB 9-18.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 25mm, thick 75mm wide in
two halves with panels provided with NUWUD (MDF) of 18mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 1980.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2009-10/P.No. 48/9.54)

9.55 KSRB 9-18.5 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 25mm, thick 75mm wide in
two halves with panels provided with NUWUD (MDF) of 12mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 1930.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2009-10/P.No. 48/9.55)

9.56 KSRB 9-19.1 : Providing and fixing in position Teak wood half panelled
shutters at bottom and half glazed at top for window shutters with styles
and rails of 35mm, thick 75mm wide in two halves with panels of 25mm
thick, 3mm thick reeded glass for top parnels fixed with wooden beading Sqm 4950.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 48/9.56)

9.57 KSRB 9-19.2 : Providing and fixing in position Honne wood half panelled
shutters at bottom and half glazed at top for windows shutters with styles
and rails of 35mm, thick 75mm wide in two halves with panels of 25mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 2700.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 48/9.57)

9.58 KSRB 9-19.3 : Providing and fixing in position Matti / Nandi wood half
panelled shutters at bottom and half glazed at top for windows shutters
with styles and rails of 35mm, thick 75mm wide in two halves with panels
of 25mm thick 3mm thick reeded glass for top panels fixed with wooden Sqm 2280.00
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No. 48/9.58)

9.59 KSRB 9-19.4 : Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for windows shutters with Honne
wood styles and rails of 35mm, thick 75mm wide in two halves with panels
filled with NUWUD (MDF) of 18mm thick 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour Sqm 2400.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures) Specification No. KBS 9.34, 9.42, 9.26.3 (PWD SR 2009-
10/P.No.48/9.59)
9.60 KSRB 9-20.1 : Providing and fixing in position Teak wood half paneled
shutters at bottom and half glazed at top for windows shutters with styles
and rails of 30mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 4400.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 PWD SR 2009-10/P.No.49/9.60)

9.61 KSRB 9-20.2 : Providing and fixing in position Honne wood half paneled
shutters at bottom and half glazed at top for windows shutters with styles
and rails of 30mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 2450.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 PWD SR 2009-10/P.No. 49/9.61)

9.62 KSRB 9-20.3 : Providing and fixing in position Mathi / Nandi wood half
paneled shutters at bottom and half glazed at top for windows shutters with
styles and rails of 30mm, thick 75mm wide in two halves with panels of
20mm thick 3mm thick reeded glass for top panels fixed with wooden Sqm 2090.00
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No.49/9.62)

9.63 KSRB 9-20.4 : Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for windows shutters with Honne
wood styles and rails of 30mm, thick 75mm wide in two halves with panels
filled with NUWUD (MDF) of 18mm thick 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour Sqm 1970.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures) Specification No. KBS 9.34, 9.42, 9.26.3 (PWD SR 2009-
10/P.No.49/9.63)

9.64 KSRB 9-21.1 : Providing and fixing in position half panelled shutters at
bottom and half glazed at top for windows shutters with Teak wood styles
and rails of 25mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 4050.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No.49/9.64)

9.65 KSRB 9-21.2 : Providing and fixing in position half panelled shutters at
bottom and half glazed at top for windows shutters with Honne wood styles
and rails of 25mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading
Sqm 2345.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 49/9.65)

9.66 KSRB 9-21.3 : Providing and fixing in position half panelled shutters at
bottom and half glazed at top for windows shutters with Matti / Nandi wood
styles and rails of 25mm, thick 75mm wide in two halves with panels of
20mm thick 3mm thick reeded glass for top panels fixed with wooden
beading including cost of materials, labour charges, HOM of machineries Sqm 2020.00
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No. 49/9.66)
9.67 KSRB 9-21.4 : Providing and fixing in position windows half panelled
shutters at bottom and half glazed at top for windows shutters with Honne
wood styles and rails of 25mm, thick 75mm wide in two halves with panels
filled with NUWUD (MDF) of 18mm thick 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour
Sqm 1830.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures) Specification No. KBS 9.34, 9.42, 9.26.3 (PWD SR 2009-
10/P.No. 49/9.67)

9.68 KSRB 9-22.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 35mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 3470.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 49/9.68)

9.69 KSRB 9-22.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 35mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 1950.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 49/9.69)

9.70 KSRB 9-23.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 30mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete
Sqm 3140.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 49-50/9.70)

9.71 KSRB 9-23.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 30mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 1800.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No.50/9.71)

9.72 KSRB 9-24.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 25mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 2820.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 50/9.72)

9.73 KSRB 9-24.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 25mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 1650.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2009-10/P.No. 50/9.73)
9.74 KSRB 9-25.1 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Teak wood styles and rails of
30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 4280.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No. 50/9.74)

9.75 KSRB 9-25.2 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Honne wood styles and rails of
30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 2440.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No. 50/9.75)

9.76 KSRB 9-25.3 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Matti / Nandi wood styles and
rails of 30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm
thick reeded glass fixed with wooden beading of size 10mm wide flushed
to the thickness of the frame including cost of materials, labour charges, Sqm 2100.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No.
50/9.76)

9.77 KSRB 9-26.1 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Teak wood styles and rails of
25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 2500.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No. 50/9.77)

9.78 KSRB 9-26.2 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Honne wood styles and rails of
25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 1500.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No. 50/9.78)

9.79 KSRB 9-26.3 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Matti / Nandi wood styles and
rails of 25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm
thick reeded glass fixed with wooden beading of size 10mm wide flushed
to the thickness of the frame including cost of materials, labour charges, Sqm 1300.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.42 (PWD SR 2009-10/P.No.
50/9.79)

9.80 KSRB 9-27.1 : Fixing of door frame in an existing opening including


embeding Nos frame in floor and walls after cutting masonry for holdfasts
for embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good Nos. 660.00
the damagest to walls and floors as required and disposal of the debries
with lead upto 50 m. including cost of materials, labour charges, complete
as per specification (PWD SR 2009-10/P.No. 50/9.80)
9.81 KSRB 9-27.2 : Fixing of windows frame in an existing opening including
embedding frame in floor and walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good
Nos. 460.00
the damagest to walls and floors as required and disposal of the debries
with lead upto 50 m. including cost of materials, labour charges, complete
as per specification (PWD SR 2009-10/P.No. 50/9.81)

9.82 KSRB 9-27.3 : Fixing of ventilator frame in an existing opening including


embedding frame in walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good
the damages to walls and floors as required and disposal of the debries Nos. 335.00
with lead upto 50 m. including cost of materials, labour charges, complete
as per specification (PWD SR 2009-10/P.No. 50/9.82)

9.83 "SOLID PANEL PVC DOOR SHUTTER Providing and fixing 30mm thick
factory made rigid foam panelled Door Shutters made from M.S. tube of 19
gauge thickness, size 19x19mm for styles and 15 x 15mm for top & bottom
rails, covered with heat moulded PVC 'C' channel of 5mm thick sheet & 30
x 50mm wide to form styles & 5mm thick & 75mm wide PVC sheets for top
rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC
sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC
sheet fitted in the M.S. Frame, Sealed to the styles & rails with 5 x 30mm Sqm 1550.00
PVC sheet beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.
(PWD SR 2009-10/P.No. 51/9.83)

9.84 "SOLID PVC DOOR FRAME" Providing and fixing factory made PVC door
frame of size 50 x 47mm with a wall thickness of 5mm, made out of
extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2
No.s of 150mm long brackets of 15 x 15mm M.S. Square tube, the entire
door frame to be reinforced with 19 x19mm M.S. Square tube fo 19 guage. Sqm 205.00
The door frame to be fixed to the wall using M.S. Screws of 65/80mm size
complete as per manufatures specifications & direction of Engineer-in-
charge. (PWD SR 2009-10/P.No. 51/9.84)

9.85 "SOLID PANEL PRELAM PVC DOOR SHUTTER Providing and fixing
30MM thick factory made rigid foam Prelam Panelled Door Shutters made
from M.S. tube of 19 x 19mm, 19 gauge for styles and 15 x 15mm for top
& bottom rails, covered with heat moulded Prelaminated PVC 'C' Channel
of 5mm thick sheet & 30 x 50mm wide to form styles & 5mm thick & 75mm
wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either
side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail &
bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side
fitted in the M.S Frams, Sealed to the styles & rails with PVC Designer
beading on either side & joined together with solvent cement adhesive
etc., Complete as per manufacturers specification & direction of Engineer-
in-charge fixed to frames with 3 nos of 75mm. Aluminium hinges. (PWD
SR 2009-10/P.No. 51/9.85)
9.85.1 "SOLID PANEL PRELAM PVC DOOR SHUTTER Providing and fixing
30MM thick factory made rigid foam with both side Prelam Panelled Door
Shutters made from M.S. tube of 19 x 19mm, 19 gauge for styles and 15 x
15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC 'C' Channel of 5mm thick sheet & 30 x 50mm wide to form styles &
5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail &
bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as
gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Sqm 2000.00
Prelaminated on either side fitted in the M.S Frams, Sealed to the styles &
rails with PVC Designer beading on either side & joined together with
solvent cement adhesive etc., Complete as per manufacturers
specification & direction of Engineer-in-charge fixed to frames with 3 nos of
75mm. Aluminium hinges. (PWD SR 2009-10/P.No. 51/9.85.1)

9.85.2 "SOLID PANEL PRELAM PVC DOOR SHUTTER Providing and fixing
30MM thick factory made rigid foam with one side Prelam Panelled Door
Shutters made from M.S. tube of 19 x 19mm, 19 gauge for styles and 15 x
15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC 'C' Channel of 5mm thick sheet & 30 x 50mm wide to form styles &
5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail &
bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as
Sqm 1950.00
gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet
Prelaminated on either side fitted in the M.S Frams, Sealed to the styles &
rails with PVC Designer beading on either side & joined together with
solvent cement adhesive etc., Complete as per manufacturers
specification & direction of Engineer-in-charge fixed to frames with 3 nos of
75mm. Aluminium hinges. (PWD SR 2009-10/P.No. 51/9.85.2)

9.86 "PVC DOOR SHUTTER (Nandi or Equivalent) Supply and fixing of door
shutters made of rigid PVC extruded hollow section (Nandi or equivalent)
of 20mm x 200mm with the wall thickness of 1.0mm +/0.1mm equally
divided into 4No's with tongue and groove locking arrangements. The
shutter frame is made of 58 x 24mm with the wall thickness of 1.5mm +/-
0.15mm section metricut and joined at 4 conrners with 125mm x 225mm Sqm 1330.00
plastic brackets. The shutter shall be horizontally reinforced with 2Nos. of
8mm PVC rods. Teak wood dattoms shall be reinforced inside the door
shutter during the fabrication of the door shutter at those points wherever
the hardware is fixed on to the door shutter. (PWD SR 2009-10/P.No.58-
51/9.86)

9.87 Supply and fixing of door shutters made of rigid PVC extruded hollow
section (Nandi or equivalent) of 20mm x 200mm with the wall thickness of
1.0mm +/0.1mm equally divided into 4No's with tongue and groove locking
arrangements. The shutter frame is made of 30 x 79mm with the wall
thickness of 1.5mm +/-0.15mm section metric cut and joined at 4 conrners
with 125mm x 225mm plastic brackets. The shutter shall be horizontally Sqm 1475.00
reinforced with 2Nos. of 8mm PVC rods. Teak wood dattoms shall be
reinforced inside the door shutter during the fabrication of the door shutter
at those points wherever the hardware is fixed on to the door shutter.
(PWD SR 2009-10/P.No. 52/9.87)

9.88 Supply and fixing of door frame made of hollow extruded PVC Section
(Nandi or equivalent) having dimension of 40 x 57mm with the wall
thickness of 2.0mm +/0.2mm duly reinforced with seasoned wood plank at m 180.00
the hinges side. The door frame top 2 corners shall be metric cut/weilded.
(PWD SR 2009-10/P.No. 52/9.88)

9.89 Supply and fixing of door frame made of hollow extruded PVC Section
(Nandi or equivalent) having dimension of 40 x 46mm with the wall
thickness of 2.0mm +/0.2mm duly reinforced with seasoned wood plank at m 165.00
the hinges side. The door frame top 2 corners shall be metric cut/welded.
(PWD SR 2009-10/P.No. 52/9.89)
9.90 Providing and fixing factory made splendor of solid core single leaf rigid
composite polymer laminated sal wood, door shutter of required thickness,
manufactured out of solid core door conforming to IS 2202 (Part-1) 1991,
laminated with 0.8 mm thick polymer, termite, water resistant and fire
retardant with superior gluing based on vacum lamination technology and
with various pre moulded design on both faces conforming to IS 6307-
1985, using adhesive conforming to IS 4835-1979 and door shutters
tested in conformation is IS 4020-1994. The finish of shutters will be
TEADK/OAK/CEDAR/ROSE WOOD/WALNUT, plain colours
WHITE/VORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot. (PWD SR 2009-
10/P.No. 52/9.90)

9.90.1 Providing and fixing factory made splendor of solid core single leaf rigid
composite polymer laminated sal wood with door shutter 30mm thick of
required thickness, manufactured out of solid core door conforming to IS
2202 (Part-1) 1991, laminated with 0.8 mm thick polymer, termite, water
resistant and fire retardant with superior gluing based on vacum lamination
technology and with various pre moulded design on both faces conforming
to IS 6307-1985, using adhesive conforming to IS 4835-1979 and door Sqm 2420.00
shutters tested in conformation is IS 4020-1994. The finish of shutters will
be TEADK/OAK/CEDAR/ROSE WOOD/WALNUT, plain colours
WHITE/VORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot. (PWD SR 2009-
10/P.No. 52/9.90.1)

9.90.2 Providing and fixing factory made splendor of solid core single leaf rigid
composite polymer laminated sal wood with door shutter 35mm thick of
required thickness, manufactured out of solid core door conforming to IS
2202 (Part-1) 1991, laminated with 0.8 mm thick polymer, termite, water
resistant and fire retardant with superior gluing based on vacum lamination
technology and with various pre moulded design on both faces conforming
to IS 6307-1985, using adhesive conforming to IS 4835-1979 and door Sqm 2750.00
shutters tested in conformation is IS 4020-1994. The finish of shutters will
be TEADK/OAK/CEDAR/ROSE WOOD/WALNUT, plain colours
WHITE/VORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot. (PWD SR 2009-
10/P.No.52/9.90.2)

9.91 Providing and fixing factory made 30mm PVC rigid foam (FOREX) PANEL
DOORS Rajashree made from MS tube of 19 guage, size of 19mm x
19mm and covered with heat moulded PVC 'C' Channel of 5mm thick and
width of 50mm to form styles and rails. The inner panel should be inserted
in between the frame with 5mm thick PVC rigid foam sheet, welded/sealed Sqm 1900.00
to the styles and rails along with 5mm PVC, beeding on all and either
sides. The vertical tubes may be filled with suitable wood material to
further enhance the screw holding capacity (PWD SR 2009-10/P.No.
52/9.91)

9.92 Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a
wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet,
mitre cut at two corners and joined with 2 No.s of 150mm long brackets of
15 x 15mm M.S Square tube. The two vertical door profiles are to be
reinforced with 19x19mm M.S. Square tube of 19 guage, EPDM rubber
gasket weather seal to be provided through out the frame. The door m 280.00
screws through the frame by using PVC fasteners. A minimum of 4 Nos. of
screws to be provided for each vertical member & minimum 2 Nos. for
horizontal member. (PWD SR 2009-10/P.No. 52/9.92)
9.93 Providing and fixing factory made single leaft rigid GRP Sandwich
composite door shutter of 32mm thick, laminated with two GRP skins with
wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and on
layer of 450 gsm E-Glass Chopped strand Mat (CSM) impregnated with
orthopthalic polyster resin. The thickness of the skins shall not be less than
1.5mm. Expanded Polystyrece (EPS) structural foam panel of 29mm
thickness and a density of 20 kg/m3 shall be used as core material.
Wooden reinforcements made of Seasoned Salwood block of cross
section not less than 28mm x 32mm and also necessary salwood
reinforcements for fixing the metal fittings such as tower bolts, aldrops,
handles, etc., shall be provided. A structural adhesive compatible with EPS
foam shall be used for Sqm 2400.00

bonding the core material, the Salwood reinforcement and the skins. The
material and process for manufacturing the door shutters shall confirm to
RV/TIFAC Composites Design centre Standards and specifications and
the door shutters tested in confiramation to IS 4020-1994. The finish of
shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour
using high quality pigments. Exclusing cost of fixtures and inclusive of
supply of shutters to respective work spot. (PWD SR 2009-10/P.No.
53/9.93)

9.94 Providing and fixing factory made single leaf rigid GRP Sandwich
composite door shutter of 40mm thick, laminated with two GRP skins with
wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and
one layer of 450 gsm E-Glass Chopped strand Mat (CSM) impregnated
with orthopthalic polyster resin. The thickness of the skins shall not be less
than 1.5mm. Expanded Polystyrece (EPS) structural foam panel of 37mm
thickness and a density of 20 kg/m3 shall be used as core material.
Wooden reinforcements made of Seasoned Salwood block of cross
section not less than 36mm x 32mm and also necessary salwood
reinforcements for fixing the metal fittings such as tower bolts, aldrops,
handles, etc., shall be provided. A structural adhesive compatible with EPS
foam shall be used for Sqm 3000.00

bonding the core material, the Salwood reinforcement and the skins. The
material and process for manufacturing the door shutters shall confirm to
RV/TIFAC Composites Design centre Standards and specifications and
the door shutters tested in confiramation to IS 4020-1994. The finish of
shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour
using high quality pigments. Exclusing cost of fixtures and inclusive of
supply of shutters to respective work spot. (PWD SR 2009-10/P.No.
53/9.94)

9.95 Providing and fixing 65mm x 90mm GRP Doorframe fabricated using E-
Glass Chopped Strand Mat (CSM). U.V-stabilized Isopthalic Gelcoat and
Isopthalic resin. The thickness of the GRP skin shall not be less than
2.0mm. The door frame consists of four segments. which are provided with
plug-in-socket arrangement in-situ in the mould. The segments are
plugged in and are joined together by means of screws. The GRP frame
shall be provided with wooden reinforcement of 6 locations fro high screw
holding capacity for fixing metallic hold fast and shall be consolidated by m 360.00
filling with medium density foam/Plaster with fibre reinforcement. Six
numbers of 260 mm x 25mm x 5mm size 'S' shaped M.S. flat hold fast
shall be provided with the frame. (PWD SR 2009-10/P.No. 53-54/9.95)
9.96 Providing and fixing 65mm x 125mm GRP Doorframe fabricated using E-
Glass Chopped Strand Mat (CSM). U.V-stabilized Isopthalic Gelcoat and
Isopthalic resin. The thickness of the GRP skin shall not be less than
2.0mm. The door frame consists of four segments. which are provided with
plug-in-socket arrangement in-situ in the mould. The segments are
plugged in and are joined together by means of screws. The GRP frame
shall be provided with wooden reinforcement on 6 locations fro high screw
holding capacity for fixing metalling hold fast and shall be consolidated by m 420.00
filling with medium density foam/Plaster of Pairs with fibre reinforcement.
Six numbers of 260 mm x 25mm x 5mm size 'S' shaped M.S. flat hold fast
shall be provided with the frame. (PWD SR 2009-10/P.No. 54/9.96)

9.97 Providing GRP Unbreakable railings available in a wide range of attractive


colours made out of cross section > 70 mm x 64mm of standard lenght 7
feet (approximate 3.6 Kg/m). The material and process for manufacturing
reilings shall confirm to RV-TIFAC composites design centre standards Each 330.00
and specifications. (PWD SR 2009-10/P.No. 54/9.97)

9.98 Providing and fixing RCC door frames factory manufactured, with C.C. 1:1
1/2:3 reinforced with 3 Nos. of 6 mm dia. Main bars and 6mm dia. Stirrups
welded at 30cm C/C, vibrating, curing including cost of steel and
fabrication charges having 3 Nos. of hinges with 20mm x 3mm M.S. flat
welded with required iron roads and flats with drilling and fixing 4 No. of flat
screw nuts each in concrete for fixing hinges and making necessary
provision in concrete for fixing aldorps, tower bolts etc., including cost of m 165.00
one coat of oil based enamel primer, 4 No. of hold fasts, 3 Nos. ISS Iron
oxidised hinges necessary metal screws etc., compelte 60 mm x 100 mm
size-Door frames. (PWD SR 2009-10/P.No. 54/9.98)

WATER PROOFING

10.1 KSRB 10.1: Providing lime concrete terracing on roofing, for weather proof
course, average thickness 100mm, laid to slope with 25mm nominal size
brick jelly and 50% lime surkhi mortar 1:2 (one lime putty two surkhi)
rammed and finished with gur and Belgiri treatment rounding off junctions
Sqm 232.00
with parapets including cost of materials, labour complete as per
specifications. Specification No. KBS 10.4.2 (PWD SR 2009-10/P.No.
56/10.1)

10.2 KSRB 10.2: Providing and laying in position yelahanka tiles of size 250 x
250mm of approved quality and make, over a bed of cement mortar 1:3 an
average thickness 25mm over weather proof course and pointed with
cement mortar 1:3 mix with red oxide including curing cost of materials, Sqm 520.00
labour complete as per specification. Specification No. KBS (PWD
SR2009-10/P.No. 56/10.2)
10.3 KSRB 10.3: Providing and laying integral cement based waterproofing
treatment including preparation of surface as required for treatment of
roofs, balconies, terraces etc., consisting of following application. (a)
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with proprietary water proofing compound conforming to
IS:2645 over the RCC slab after cleaning the surface before treatments.
(b) Laying cement concrete using broken brick bats 25mm to 100mm size
with 50% of cement mortar 1:5 admixed with proprietary water proofing
compound conforming IS : 2645 over 20mm thick layer of cement mortar
1:5 admixed with proprietary water proofing compound to required slope
and treating similarly the adjoining walls upto 300 mm height including
rounding off junctions of walls and slabs. (c) After two days of proper Sqm 510.00
curing, applying a second coat of cement slurry admixed with proprietary
water proofing compound (d) Finishing the surface with 20mm thick
jointless cement mortar of mix 1:4

admixed with proprietary water proofing compound and finally finishing the
surface with trowel and neat cement. slurry and making of 300 x 300 mm
square. (e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test including cost of
materials, labour complete as per specifications. (PWD SR2009-10/P.No.
56/10.40)

10.4 KSRB 10.4: Providing and laying four courses water proofing treatment
with bitumen felt over roof consisting of first and third courses of blown
and / or residual bitumen applied hot at 1.45 kg / sqm of area for each
course second course of roofing felt Type -3 grade-I (heassian based self
finish bitumen felt) and forth and final course of stone grit 6mm and down
size or pea sized gravel spread at 0.06 cum./sqm including preparation of Sqm 250.00
surface but excluding grading complete with bitumen felt (hessian based)
Type - 3 grade -! blown or / and residual bitumen applied hot 1.4 kg/sqm
including cost of materials, labour complete as per specifications. KBS
10.4.3 (PWD SR2009-10/P.No. 56/10.4)

10.5 KSRB 10.5: Providing and laying six courses water proofing treatment with
bitumen felt over roof consisting of first, third and fifth courses of blown
and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of
area for respectively, second and fourth courses of roofing felt Type - 2
grade-I (fibre based self finish bitumen felt) and sixth and final course of Sqm 485.00
stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. /
sqm including preparation of surface, excluding grading but including cost
of materials, labour complete as per specifications. KBS 10.4.3 (PWD
SR2009-10/P.No. 56/10.40)

10.6.1 Chipping and cleaning, construction joint and slab joint, treatment, grouting
of honey comb by cement with inorganic accelerator for cement, spray of
biological modified Ortho esters and alkaline earth, providing and laying p
patch concrete 1:2:4 for required thickness by clean granite trap jelly
20mm and down size mixed with poly carboxylic sulphonated heutral
cellulose at 100ml/bag and aqueous acrylic silicone emulstion @
125ml/bag and aqueous acrylic silicone emulstion @ 125ml/bag, slurry of
cement and silica sand should be mixed with Cross linked 695.00
Acrylic/Stryrene/butadiene based polymer, spraying of silane and silanol
linear copolymer as water broof agent, applying of modified polymers
slurry of soft acrylic esters for extra protection for taking, and filling the
bore wherever concrete, brushing one coat of acrylic copolymer cross
linked formulation on the bore.for roof (PWD SR 2009-10/P.No. 57/10.2)
10.6.2 Chipping and cleaning (Roof), construction joint and slab joint, treatment,
grouting of honey comb by cement with inorganic accelerator for cement,
spray of biological modified Ortho esters and alkaline earth, providing and
laying p patch concrete 1:2:4 for required thickness by clean granite trap
jelly 20mm and down size mixed with poly carboxylic sulphonated heutral
cellulose at 100ml/bag and aqueous acrylic silicone emulstion @
125ml/bag and aqueous acrylic silicone emulstion @ 125ml/bag, slurry of
cement and silica sand should be mixed with Cross linked
Acrylic/Stryrene/butadiene based polymer, spraying of silane and silanol Sqm 765.00
linear copolymer as water broof agent, applying of modified polymers
slurry of soft acrylic esters for extra protection for taking, and filling the
bore wherever concrete, brushing one coat of acrylic copolymer cross
linked formulation on the bore. For Planter box, terrace garden, OHT
and Sump tank, for sunken toilet. (PWD SR 2009-10/P.No. 57/10.2.2)

10.7 Cleaning of water tanks after scrubbing the wall and floor, washing with
bleaching powder and cleaning the walls and floor, including pumping and
bailing out of water, including cost of all materials, labour lead lift etc., Sqm 18.00
complete.PWD SR2009-10 P.No.57/10.7

10.8 Providing and applying food grade epoxy painting to over head tank and
sump tank after cleaning and drying including pumping and bailing out of
Sqm 75.00
water, including cost of all materials, labour lead lify etc., complete.PWD
SR2009-10 P.No.57/10.8

10.9.1 Chipping and cleaning (Roof), construction joint and slab joint, treatment,
grouting of honey comb by cement with inorganic accelerator for cement,
spray of biological modified Ortho esters and alkaline earth, providing and
laying p patch concrete 1:2:4 for required thickness by clean granite trap
jelly 20mm and down size mixed with poly carboxylic sulphonated heutral
cellulose at 100, :/bag and aqueous acrylic silicone emulstion @
125ml/bag and aqueous acrylic silicone emulstion @ 125ml/bag, slurry of
cement and silica sand should be mixed with Cross linked Sqm 700.00
Acrylic/Stryrene/butadiene based polymer, spraying of silane and silanol
linear copolymer as water proof agent, applying of modified polymers
slurry of soft acrylic esters for extra protection for taking, and filling the
bore wherever concrete, brushing one coat of acrylic copolymer cross
linked formulation on the bore. For Roof (PWD SR 2009-10/P.No.
57/10.2.1)

10.9.2 Chipping and cleaning (Roof), construction joint and slab joint, treatment,
grouting of honey comb by cement with inorganic accelerator for cement,
spray of biological modified Ortho esters and alkaline earth, providing and
laying p patch concrete 1:2:4 for required thickness by clean granite trap
jelly 20mm and down size mixed with poly carboxylic sulphonated heutral
cellulose at 100, :/bag and aqueous acrylic silicone emulstion @
125ml/bag and aqueous acrylic silicone emulstion @ 125ml/bag, slurry of
cement and silica sand should be mixed with Cross linked 770.00
Acrylic/Stryrene/butadiene based polymer, spraying of silane and silanol
linear copolymer as water proof agent, applying of modified polymers
slurry of soft acrylic esters for extra protection for taking, and filling the
bore wherever concrete, brushing one coat of acrylic copolymer cross
linked formulation on the bore. For Roof For Planter box, terrace garden,
OHT and Sump tank, for sunken toilet. (PWD SR 2009-10/P.No.
57/10.9.2)

DRAINAGE WORK
11.1 KSRB 12-1.1 : Providing and laying in position to required level or slope
100mm internal diameter salt glazed stoneware pipes grade A and
jointing with stiff mixture of cement mortar in proportion of 1:1, testing of
pipes and joints, including cost of materials, labour charges complete as m 225.00
per specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.1)

11.2 KSRB 12-1.2 : Providing and laying in position to required level or slope
150mm internal diameter salt glazed stoneware pipes grade A and
jointing with stiff mixture of cement mortar in proportion of 1:1, testing of
pipes and joints, including cost of materials, labour charges complete as m 345.00
per specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.2)

11.3 KSRB 12-1.3 : Providing and laying in position to required level or slope
200mm internal diameter salt glazed stoneware pipes grade A and
jointing with stiff mixture of cement mortar in proportion of 1:1, testing of
pipes and joints, including cost of materials, labour charges complete as
m 470.00
per specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.3)

11.4 KSRB 12-1.4 : Providing and laying in position to required level or slope
230mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 510.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.4)

11.5 KSRB 12-1.5 : Providing and laying in position to required level or slope
250mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 530.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.5)

11.6 KSRB 12-1.6 : Providing and laying in position to required level or slope
300mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 560.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.6)

11.7 KSRB 12-1.7 : Providing and laying in position to required level or slope
350mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009- m 600.00
10/P.No.59/11.7)
11.8 KSRB 12-1.8 : Providing and laying in position to required level or slope
400mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 645.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.8)

11.9 KSRB 12-1.9 : Providing and laying in position to required level or slope
450mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 780.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2009-
10/P.No.59/11.9)

11.10 KSRB 12-2.1 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 100 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 145.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.10)

11.11 KSRB 12-2.2 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 150 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 244.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.11)

11.12 KSRB 12-2.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 200 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 270.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.12)

11.13 KSRB 12-2.4 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 230 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 293.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.13)

11.14 KSRB 12-2.5 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 250 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 305.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.14)
11.15 KSRB 12-2.6 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 300 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 345.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.15)

11.16 KSRB 12-2.7 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 350 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 390.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.16)

11.17 KSRB 12-2.8 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 400 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 430.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.17)

11.18 KSRB 12-2.9 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 450 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 470.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.59/11.18)

11.19 KSRB 12-3.1 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 100mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 214.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.59/11.19)

11.20 KSRB 12-3.2 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 150mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 345.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.20)
11.21 KSRB 12-3.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 200mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 405.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.21)

11.22 KSRB 12-3.4 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 230mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 465.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.22)

11.23 KSRB 12-3.5 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 250mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 475.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.23)

11.24 KSRB 12-3.6 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 300mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 545.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.24)

11.25 KSRB 12-3.7 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 350mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 625.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.25)

11.26 KSRB 12-3.8 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 400mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 700.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.26)
11.27 KSRB 12-3.9 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 450mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 785.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2009-10/P.No.60/11.27)

11.28 KSRB 12-4.1 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 100mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 455.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.28)

11.29 KSRB 12-4.2 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 150mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 550.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.29)

11.30 KSRB 12-4.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 200mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 645.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.30)

11.31 KSRB 12-4.4 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 230mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 705.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.31)

11.32 KSRB 12-4.5 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 250mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 745.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.32)

11.33 KSRB 12-4.6 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 300mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 850.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.33)
11.34 KSRB 12-4.7 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 350mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 970.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.34)

11.35 KSRB 12-4.8 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 400mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 1080.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.35)

11.36 KSRB 12-4.9 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 450mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 1190.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2009-
10/P.No.60/11.36)

11.37 KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91m
internal dia at bottom 0.91m deep and 0.56m dia at top with table moulded
non - modular bricks of 50 class designation 50 in cement mortar 1:4,
inside cement plastered 12 mm thick with cement mortar 1:3, finished with
a floating coat of neat cement, foundation concrete 1:3:6 mix using 40mm
and downsize granite metal and making necessary channel in cement
concrete 1:2:4 mix with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS : 12592,
total weight cover and frame to be not less than 182 kg, fixed in cement Nos. 8360.00
concrete 1:2:4, 20mm and downsize broken granite metal, providing and
removing centering, shuttering including cost of materials, labour charges,
HOM of machineries complete as per specification. (Excavation, footrests
and 12mm thick cement plaster on the external surface shall be paid
seperately) Specification No. KBS 12.4 (PWD SR 2008-
09/P.No.60/11.37)

11.38 KSRB 12-5.2 : Constructing brick masonry circular type manhole 0.91m
internal dia at bottom 1.67m deep and 0.56m dia at top with table
moulded non - modular bricks of class designation 50 in cement mortar
1:4, inside cement plastered 12 mm thick with cement mortar 1:3, finish
with a floating coat of neat cement, foundation concrete 1:3:6 mix using
40mm and downsize granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm and downsize granite metal finished
with a floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming IS :
12592, total weight cover and frame to be not less than 182 kg, fixed in
cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 12480.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2008-09/P.No.70/11.38)
11.39 KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22m
internal dia at bottom 1.68m deep and 0.56m dia at top with table moulded
non - modular bricks of class designation 50 in cement mortar 1:4, inside
cement plastered 12 mm thick with cement mortar 1:3, finished with a
floating coat of neat cement, foundation concrete 1:3:6 mix using 40mm
and downsize granite metal and making necessary channel in cement
concrete 1:2:4 mix with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS : 12592,
total weight length of cover and frame to be not less than 182 kg, fixed in
cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 15560.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2008-09/P.No.61/11.39)

11.40 KSRB 12-5.4 : Constructing brick masonry circular type manhole 1.22m
internal dia at bottom 2.29m deep and 0.56m dia at top with table moulded
and non - modular bricks of class designation 50 in cement mortar 1:4,
inside cement plastered 12 mm thick with cement mortar 1:3, finished with
a floating coat of neat cement, foundation concrete 1:3:6 mix using 40mm
and downsize granite metal and making necessary channel in cement
concrete 1:2:4 mix with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS : 12592,
total weight length of cover and frame to be not less than 182 kg, fixed in
cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 18500.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2008-09/P.No.61/11.40)

11.41 KSRB 12-5.5 : Constructing brick masonry circular type manhole 1.52m
internal dia at bottom 2.30m deep and 0.56m dia at top with table
moulded and non - modular bricks of class designation 50 in cement
mortar 1:4, inside cement plastered 12 mm thick with cement mortar 1:3,
finished with a floating coat of neat cement, foundation concrete 1:3:6 mix
using 40mm and downsize granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm and downsize granite metal finished
with a floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming IS :
12592, total weight length of cover and frame to be not less than 182 kg,
fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 25430.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2008-09/P.No.61/11.41)
11.42 KSRB 12-5.6 : Constructing brick masonry circular type manhole 1.52m
internal dia at bottom4.18m deep and 0.56m dia at top with table
moulded and non - modular bricks of class designation 50 in cement
mortar 1:4, inside cement plastered 12 mm thick with cement mortar 1:3,
finished with a floating coat of neat cement, foundation concrete 1:3:6 mix
using 40mm and downsize granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm and downsize granite metal finished
with a floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming IS :
12592, total weight length of cover and frame to be not less than 182 kg,
fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 47390.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2008-09/P.No.61/11.42)

11.43 KSRB 12-5.3 : Constructing circular type manhole 1500mm internal dia
at bottom, 525mm diat at top in brick masonry with 1:5, cement mortar,
cement plaster 1:3 finish with a floating coat of neat cement, RCC 1:2:4
top slab using 20mm and down size granite metal, foundation concrete
1:4:8 using 40mm and down size granite metal and making channels in
cement concrete 1:2:4 mix using 20mm and down size granite metal,
neatly finished curing, fixing CI cover complete including of materials, Nos. 25790.00
labour charges, HOM of mechineries complete as per specifications
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD
SR2009-10/P.No.61/11.43)

11.44 KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole
with 1:3:6 cement concrete block of 20x20x10 cms, using 20mm and down
size metal of size including cost of materials, labour charges curing Nos. 173.00
complete as per specifications. Specification No. KBS 12.4.6 (PWD
SR2009-10/P.No.62/11.44)

11.45 KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole
with 1:3:6 cement concrete block of 20x20x10 cms, using 20mm and down
size metal of size including cost of materials, labour charges curing Nos. 149.00
complete as per specifications. Specification No. KBS 12.4.6 (PWD
SR2009-10/P.No.62/11.45)

11.46 KSRB 12-6.3 : Providing cast iron footrest and fixing in manhole with 1:3:6
cement concrete block of 20x20x10 cms, using 20mm and down size
metal of size including cost of materials, labour charges curing complete Nos. 135.00
as per specifications. Specification No. KBS 12.4.6 (PWD SR2009-
10/P.No.62/11.46)

11.47 KSRB 12-7.1 : Making connection of drain or sewer line of size 100 to
230mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3,
finished with a floating coat of neat cement, and making necessary Nos. 940.00
channels for the drain, including cost of materials, labour charges, curing
complete as per specifications. (PWD SR2009-10/P.No.62/11.47)
11.48 KSRB 12-7.2 : Making connection of drain or sewer line of size 250 to
300mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3,
finished with a floating coat of neat cement, and making necessary Nos. 1240.00
channels for the drain, including cost of materials, labour charges, curing
complete as per specifications. (PWD SR2009-10/P.No.62/11.48)

11.49 KSRB 12-7.3 : Making connection of drain or sewer line of size 350 to
450mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3,
finished with a floating coat of neat cement, and making necessary Nos. 1650.00
channels for the drain, including cost of materials, labour charges, curing
complete as per specifications. (PWD SR2009-10/P.No.62/11.49)

11.50 KSRB 12-8.1 : Constructing brick masonry inspection chamber


455x610mm, and 450mm depth, (clear inside dimension) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I. cover with frame (light duty) 455x610mm internal
dimensions, total weight of cover with frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab with
cement concrete 1:2:4 mix 20mm and down size granite metal, foundation
concrete 1:5:10 with 40mm and downsize granite metal inside plastering Nos. 4520.00
12mm thick with cement mortar 1:3, finish smooth with a floating coat of
cement on walls and bed concrete complete as per standard design
including cost of materials, labour charges curing complete as per
specifications. (PWD SR2009-10/P.No.62/11.50)

11.50.1 KSRB 12-8.1 : Constructing brick masonry inspection chamber 600 x


600mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement
mortar 1:5, C.I cover with frame (light duty) 600 x 600mm (PWD SR2009- Nos. 5900.00
10 P.No.62/11.50.1)

11.50.2 KSRB 12-8.1 : Constructing brick masonry inspection chamber 450 X


450mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement Nos. 3300.00
mortar 1:5, C.I cover with frame (light duty) 450 X 450mm (PWD SR2009-
10 P.No.63/11.50.2)

11.50.3 KSRB 12-8.1 : Constructing brick masonry inspection chamber 450 X


300mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement Nos 2250.00
mortar 1:5, C.I cover with frame (light duty) 450 X 300mm (PWD SR2009-
10 P.No.63/11.50.3)

11.50.4 KSRB 12-8.1 : Constructing brick masonry inspection chamber 230 x


150mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement Nos 750.00
mortar 1:5, C.I cover with frame (light duty) 230 x 150mm (PWD SR2009-
10 P.No.63/11.50.4)
11.51 KSRB 12-8.1.1 : Extra for item no. KSRB 12-8.1 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof
including cost of materials, labour charges, curing complete as per Each 415.00
specifications. (PWD SR2009-10/P.No.63/11.51)

11.52 KSRB 12-8.2 : Constructing brick masonry inspection chamber


500x700mm, and 450mm depth, (clear inside dimension) for pipeline, with
one or two inlets, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I. cover with frame (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not
less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C
top slab with cement concrete 1:2:4 mix 20mm and down size granite
metal, foundation concrete 1:5:10 with 40mm and downsize granite metal
Each 5050.00
inside plastering 12mm thick with cement mortar 1:3, finished smooth with
a floating coat of cement on walls and bed concrete complete as per
standard design including cost of materials, labour charges curing
complete as per specifications. (PWD SR2009-10/P.No.63/11.52)

11.53 KSRB 12-8.2.1 : Extra for item no. KSRB 12-8.2 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof
including cost of materials, labour charges, curing complete as per Each 460.00
specifications. (PWD SR2009-10/P.No.63/11.53)

11.54 KSRB 12-8.3: Constructing brick masonry inspection chamber


600x850mm, and 450mm depth, (clear inside dimension) for pipeline, with
three or more inlets, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I. cover with frame (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not
less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C
top slab with cement concrete 1:2:4 mix 20mm and down size granite
metal, foundation concrete 1:5:10 with 40mm and downsize granite metal Each 5680.00
inside plastering 12mm thick with cement mortar 1:3, finished smooth with
a floating coat of cement on walls and bed concrete complete as per
standard design including cost of materials, labour charges curing
complete as per specifications. (PWD SR2009-10/P.No.63-64/11.54)

11.55 KSRB 12-8.3.1 : Extra for item no. KSRB 12-8.3 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof
including cost of materials, labour charges, curing complete as per Each 535.00
specifications. (PWD SR2009-10/P.No.64/11.55)

SANITARY WORK
12.1 KSRB 11-1 : Providing and fixing white vitreous china clay, water closet
Indian type (Squatting pan) of size 580mm with footrests, 100mm S or P
trap, 10 litre low lavel, PVC flushing cistern (all are approved make) with
fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps,
overflow arrangements with specials and 25mm mosquito proof coupling of pan 2730.00
approved design, painting of fittings and brackets, cutting and making
good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. Specification No. KBS 11 (PWD
SR2009-10/P.No.66/12.1)

12.2 KSRB 11-2 : Providing and fixing white vitreous china clay, water closet
Orissa patten of size 580 x 440mm with integral type footrests, 100mm S
or P trap, 10 litre low lavel, PVC flushing cistern (all are approved make)
with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and
clamps, overflow arrangements with specials and 25mm mosquito proof pan 2890.00
coupling of approved design, painting of fittings and brackets, cutting and
making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications. Specification No. KBS
11 (PWD SR2009-10/P.No.66/12.2)

12.3 KSRB 11-3 : Providing and fixing white vitreous china clay, water closet
Indian type (Squatting pan) of size 580mm with footrests, 100mm S or P
trap, (approved make) cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per pan 1000.00
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.66/12.3)

12.4 KSRB 11-4 : Providing and fixing white vitreous china clay, water closet
Orissa pattern of size 580 x 440mm with Integral type footrests, 100mm S
or P trap, (approved make) cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per pan 1150.00
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.66/12.4)

12.5 KSRB 11-5 : Providing and fixing white vitreous china clay, water closet
European type(Pedestal type) with block solid plastic seat and lid, C.P.
brass hinges, rubber buffers. 10 litre low level, P.V.C. flushing cistern (all
are approved make) with fittings, C.I./ M.S brackets, 40mm diameter flush
bend with fittings and clamps, overflow arrangements with special and
25mm mosquito proof coupling of approved design, painting of fittings and Each 3400.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11. (PWD SR2009-10/P.No.66/12.5)

12.6 KSRB 11-6 : Providing and fixing white vitreous china clay, water closet
European type (Pedestal type) with block solid plastic seat and lid, C.P.
brass hinges, rubber buffers. 10 litre white glazed / vitreous china clay low
level, flushing cistern (all are approved make) with fittings, C.I./ M.S
brackets, 40mm diameter flush bend with fittings and clamps, overflow
arrangements with specials and 25mm mosquito proof coupling of
approved design, painting of fittings and brackets, cutting and making Each 3270.00
good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. Specification No. KBS 11. (PWD
SR2009-10/P.No.66-67/12.6)
12.7 KSRB 11-7.1 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430x260x350mm with 5 litres PVC automatic
flushing cistern, C.I./ M.S brackets, standard flush pipe and C.P.
brass spreaders with brass unions and G.I. clamps complete painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2460.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11. (PWD SR2009-10/P.No.67/12.7)

12.8 KSRB 11-7.2 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430 x 260x350mm in the range of two 7.5 litre
P.V.C. with automatic flushing cistern, C.I/M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps painting
of fittings and brackets, cutting and making good the wall and floor Unit 3240.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.67/12.8)

12.9 KSRB 11-7.3 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430 x 260x350mm in the range of three with
7.5 litre P.V.C. with automatic flushing cistern, C.I/M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps painting of fittings and brackets, cutting and making good the wall Unit 4390.00
and floor wherever required, including cost of materials, labour complete
as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.67/12.9)

12.10 KSRB 11-7.4 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430 x 260x350mm in the range of four with 10
litre P.V.C. automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps painting
of fittings and brackets, cutting and making good the wall and floor Unit 5300.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.67/12.10)

12.11 KSRB 11-8.1 : Providing and fixing white vitreous china clay, well corner
type, lipped front urinal basin of size 340 x 410 x 265mm with 5 litre
P.V.C. automatic flushing cistern, C.I / M.S brackets, standard flush pipe
and C.P. brass spreaders with brass unions and G.I. clamps painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2350.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.67/12.11)

12.12 KSRB 11-8.2 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340 x 410 x 265mm with in the range
of two with 7.5 litre P.V.C. automatic flushing cistern, C.I / M.S
brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps painting of fittings and brackets, cutting and making good
Unit 2920.00
the wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.67/12.12)
12.13 KSRB 11-8.3 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340 x 410 x 265mm with in the range
of three with 7.5 litre P.V.C. automatic flushing cistern, C.I / M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps painting of fittings and brackets, cutting and making good the wall
and floor wherever required, including cost of materials, labour complete Unit 3480.00
as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.67/12.13)

12.14 KSRB 11-8.4 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340 x 410 x 265mm with in the range
of four with 10 litre P.V.C. automatic flushing cistern, C.I / M.S
brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps painting of fittings and brackets, cutting and making good
the wall and floor wherever required, including cost of materials, labour 3900.00
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.67/12.14)

12.15 KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm with 5 litres P.V.C.
automatic flushing cistern, C.I / M.S brackets, standard flush pipe and
C.P. brass spreaders with brass unions and G.I. clamps C.I. dtrap with
outlet grating and other couplings in C.P. brass, painting of fittings and
brackets, cutting and making good the wall and floor wherever required, Unit 2400.00
including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.67-78/12.15)

12.16 KSRB 11-9.2 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm in the range of two with
7.5 litres P.V.C. automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps,
C.I. trap with outlet grating and other couplings in C.P. brass, painting of
Unit 3210.00
fittings and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.67/12.16)

12.17 KSRB 11-9.3 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm in the range of three
with 10 litres P.V.C. automatic flushing cistern, C.I / M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps, C.I. trap with outlet grating and other couplings in C.P. brass,
painting of fittings and brackets, cutting and making good the wall and floor Unit 4150.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.17)

12.18 KSRB 11-9.4 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm in the range of four with
10 litres P.V.C. automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps,
C.I. trap with outlet grating and other couplings in C.P. brass, painting of
Unit 5540.00
fittings and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.18)
12.19 KSRB 11-10.1 : Providing and fixing white vitreous china clay, squatting
plate with 5 litre, P.V.C. automatic flushing cistern including brass
coupling C.I / M.S brackets, G.I. flush pipe of standard size and C.P.
brass spreaders painting of fittings and brackets, cutting and making good
the wall and floor wherever required, including cost of mateirals, labour Unit 2050.00
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.68/12.19)

12.20 KSRB 11-10.2 : Providing and fixing white vitreous china clay, squatting
plate in the range of two single squatting plate with 7.5 litre P.V.C.
automatic flushing cistern including brass coupling C.I. / M.S. brackets,
G.I. flush pipe of standard size and C.P. brass spreaders painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2270.00
required, including cost of mateirals, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.20)

12.21 KSRB 11-10.3 : Providing and fixing white vitreous china clay, squatting
plate in the range of three single squatting plates with 10 litre P.V.C.
automatic flushing cistern including brass coupling C.I. / M.S. brackets,
G.I. flush pipe of standard size and C.P. brass spreaders painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2750.00
required, including cost of mateirals, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.21)

12.22 KSRB 11-10.4 : Providing and fixing white vitreous china clay, squatting
plate in the range of four single squatting plates with one number 15
litre P.V.C. automatic flushing cistem including brass coupling C.I. /
M.S. brackets, G.I. flush pipe of standard size and C.P. brass spreaders
painting of fittings and brackets, cutting and making good the wall and floor Unit 3320.00
wherever required, including cost of mateirals, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.22)

12.23 KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back
wash basin size 630 x 450mm with a pair of 15mm C.P. brass pillar
taps with C.I. / M.S brackets, 32mm C.P. brass waste of standard
pattern, painting of fittings and brackets, cutting and making good the wall Unit 2650.00
and floor wherever required, including cost of materials, labour complete
as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.68/12.23)

12.24 KSRB 11-11.2 : Providing and fixing white vitreous china clay, flat back
wash basin size 630 x 450mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1920.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.24)

12.25 KSRB 11-11.3 : Providing and fixing white vitreous china clay, flat back
wash basin size 550 x 400mm with a pair of 15mm C.P. brass pillar
taps with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per Unit 2180.00
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.25)
12.26 KSRB 11-11.4 : Providing and fixing white vitreous china clay, flat back
wash basin size 550 x 400mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1670.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.26)

12.27 KSRB 11-11.5 : Providing and fixing white vitreous china clay, flat back
wash basin size 450 x 300mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1610.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.27)

12.28 KSRB 11-11.6 : Providing and fixing white vitreous china clay, angle back
wash basin size 600 x 480mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1950.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.68/12.28)

12.29 KSRB 11-11.6 : Providing and fixing white vitreous china clay, angle back
wash basin size 400 x 400mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1740.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2009-10/P.No.69/12.29)

12.30 KSRB 11-11.8 : Providing and fixing white vitreous china clay, surgeon
type wash basin size 660 x 460mm with a pair of 15mm C.P. brass
pillar taps with pair of elbow operated levers, C.I. / M.S brackets,
32mm C.P. brass waste of standard pattern, painting of fittings and
brackets, cutting and making good the wall and floor wherever required, Unit 2930.00
including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2009-10/P.No.69/12.30)

12.31 KSRB 11-11.9 : Providing and fixing white vitreous china clay, surgeon
type wash basin size 660 x 460mm with single 15mm C.P. brass pillar taps
with single elbow operated levers, C.I. / M.S brackets, 32mm C.P. brass
waste of standard pattern, painting of fittings and brackets, cutting and
making good the wall and floor wherever required, including cost of Unit 2390.00
materials, labour complete as per specifications. Specification No. KBS 11
(PWD SR2009-10/P.No.69/12.31)

12.32 KSRB 11-12.1 : Providing and fixing kitchen sink of white glazed fire clay
of size 600 x 450 x 250mm with M.S. / C.I. brackets, C.P. brass chain with
rubber plug, 32mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the
Unit 2690.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.69/12.32)
12.33 KSRB 11-12.2 : Providing and fixing kitchen sink of white glazed fire clay
of size 750 x 450 x 250mm with M.S. / C.I. brackets, C.P. brass chain with
rubber plug, 32mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the
Unit 2780.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.69/12.33)

12.34 KSRB 11-13.1 : Providing and fixing laboratory sink of white glazed fire
clay of size 600 x 450 x 200mm with M.S. / C.I. brackets, C.P. brass
chain with rubber plug, 32mm C.P. brass waste, tap with union, brass stop
cock complete, painting of fittings and brackets, cutting and making good
Unit 2300.00
the wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.69/12.34)

12.35 KSRB 11-13.2 : Providing and fixing laboratory sink of white glazed fire
clay of size 450 x 300 x 150mm with M.S. / C.I. brackets, C.P. brass chain
with rubber plug, 32mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the
Unit 2025.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2009-
10/P.No.69/12.35)

12.36 KSRB 11-14.1 : Providing and fixing stainless steel kitchen sink
conforming to IS 13983:1994 of size 500x1575mm bowl depth 220mm,
with one bowl and two drain board, M.S. / C.I. brackets, stainless steel
plug 40mm, painting of fittings and brackets, cutting and making good the Unit 4840.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. (PWD SR2009-10/P.No.69/12.36)

12.37 KSRB 11-14.2 : Providing and fixing stainless steel kitchen sink of size
500x1000mm bowl depth 200mm, with single bowl drain board, M.S. /
C.I. brackets, stainless steel plug 40mm, painting of fittings and brackets,
cutting and making good the wall and floor wherever required, including Unit 4530.00
cost of materials, labour complete as per specifications. (PWD SR2009-
10/P.No.69/12.37)

12.38 KSRB 11-14.3 : Providing and fixing stainless steel kitchen sink of size
400x470mm bowl depth 180mm, with drain board, M.S. / C.I. brackets,
stainless steel plug 40mm, painting of fittings and brackets, cutting and
making good the wall and floor wherever required, including cost of Unit 4040.00
materials, labour complete as per specifications. (PWD SR2009-
10/P.No.69/12.38)

12.39 KSRB 11-15.1 : Providing and fixing 600 x 450mm bevel Lead edge mirror
of superior glass with 6mm hard board backing and fixed to wooden cleats
with C.P. screws, washers, including cost of materials, labour complete as Unit 925.00
per specifications. (PWD SR2009-10/P.No.69/12.39)

12.40 KSRB 11-15.2 : Providing and fixing 450 mm dia circular shape mirror
with plastic moulded frame of approved make and shade with 6mm thick
hard board backing including cost of materials, labour complete as per Unit 530.00
specifications. (PWD SR2009-10/P.No.70/12.40)
12.41 KSRB 11-15.3 : Providing and fixing 453x357 mm dia rectangular shape
mirror with plastic moulded frame of approved make and shade with 6mm
thick hard board backing including cost of materials, labour complete as Unit 950.00
per specifications. (PWD SR2009-10/P.No.70/12.41)

12.42 KSRB 11-15.4 : Providing and fixing 450x915 mm dia oval shape mirror
with plastic moulded frame of approved make and shade with 6mm thick
hard board backing including cost of materials, labour complete as per Unit 500.00
specifications. (PWD SR2009-10/P.No.70/12.42)

12.43 KSRB 11-15.5 : Providing and fixing 1500x450 mm dia rectangular


shape mirror with plastic moulded frame of approved make and shade
with 6mm thick hard board backing including cost of materials, labour Unit 1290.00
complete as per specifications. (PWD SR2009-10/P.No.70/12.43)

12.44 KSRB 11-16 : Providing and fixing 600x120 mm glass shelf supported on
alluminium angle frame with C.P. brass brackets, guard rail fixed to
wooden cleats with C.P. brass screws and washers including cost of Unit 690.00
materials, labour complete as per specifications. (PWD SR2009-
10/P.No.70/12.44)

12.45 KSRB 11-17.1 : Providing and fixing C.P. brass towel rail 740mm lenght,
20mm dia with C.P. brackets, fixed to wooden cleats with C.P. brass
screws including cost of materials, labour complete as per specifications. Unit 450.00
(PWD SR2009-10/P.No.70/12.45)

12.46 KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600mm lenght,
20mm dia with C.P. brackets, fixed to wooden cleats with C.P. brass
screws including cost of materials, labour complete as per specifications. Unit 490.00
(PWD SR2009-10/P.No.70/12.46)

12.47 KSRB 11-18.1.1 : Providing and fixing sand cast iron soil waste and vent
pipes 100 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour testing complete as per m 600.00
specifications. KBS 11-1.10 (PWD SR2009-10/P.No.70/12.47)

12.48 KSRB 11-18.1.2 : Providing and fixing sand cast iron soil waste and vent
pipes 75 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour testing complete as per m 510.00
specifications. KBS 11-1.10 (PWD SR2009-10/P.No.70/12.48)

12.49 KSRB 11-18.1.3 : Providing and fixing sand cast iron soil waste and vent
pipes 50 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour testing complete as per m 290.00
specifications. KBS 11-1.10 (PWD SR2009-10/P.No.70/12.49)

12.50 KSRB 11-18.2.1 : Providing and fixing sand cast iron soil waste bends
100 mm dia with access door, insertion of rubber washers 3mm thick
bolts and nut, with spun yarn soaked in cement slurry and cement mortar Each 270.00
1:2 including cost of materials, labour, testing complete as per
specifications. (PWD SR2009-10/P.No.70/12.50)
12.51 KSRB 11-18.2.2 : Providing and fixing sand cast iron soil waste bends
75 mm dia with access door, insertion of rubber washers 3mm thick bolts
and nut, with spun yarn soaked in cement slurry and cement mortar 1:2 Each 260.00
including cost of materials, labour, testing complete as per specifications.
(PWD SR2009-10/P.No.70/12.51)

12.52 KSRB 11-18.2.3 : Providing and fixing sand cast iron soil waste bends
50 mm dia with access door, insertion of rubber washers 3mm thick bolts
and nut, with spun yarn soaked in cement slurry and cement mortar 1:2 Each 165.00
including cost of materials, labour, testing complete as per specifications.
(PWD SR2009-10/P.No.70/12.52)

12.53 KSRB 11-18.3.1 : Providing and fixing sand cast iron soil waste plain
bend 100 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per Each 270.00
specifications. KBS 11-1.10 (PWD SR2009-10/P.No.70/12.53)

12.54 KSRB 11-18.3.2 : Providing and fixing sand cast iron soil waste plain
bend 75 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per Each 220.00
specifications. KBS 11-1.10 (PWD SR2009-10/P.No.70/12.54)

12.55 KSRB 11-18.3.3 : Providing and fixing sand cast iron soil waste plain
bend 50 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per Each 140.00
specifications. KBS 11-1.10 (PWD SR2009-10/P.No.70/12.55)

12.56 KSRB 11-18.4.1 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 100x100x100x100mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 600.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.71/12.56)

12.57 KSRB 11-18.4.2 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 75x75x75x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 480.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.71/12.57)

12.58 KSRB 11-18.4.3 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 50x50x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 420.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.71/12.58)

12.59 KSRB 11-18.5.1 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 100x100x100x100mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 550.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.71/12.59)

12.60 KSRB 11-18.5.2 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 75x75x75mm, insertion
of rubber washers 3mm thick bolts and nuts, including cost of materials, Each 470.00
labour, testing complete as per specifications. KBS 11-1.10 (PWD
SR2009-10/P.No.71/12.60)
12.61 KSRB 11-18.5.3 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 50x50x50mm, insertion
of rubber washers 3mm thick bolts and nuts, including cost of materials, Each 420.00
labour, testing complete as per specifications. KBS 11-1.10 (PWD
SR2009-10/P.No.71/12.61)

12.62 KSRB 11-18.6.1 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 100x100x75x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 510.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.71/12.62)

12.63 KSRB 11-18.6.2 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 100x100x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 440.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.71-72/12.63)

12.64 KSRB 11-18.6.3 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 75x75x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 360.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.72/12.64)

12.65 KSRB 11-18.7.1 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 100x100x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 500.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2009-10/P.No.72/12.65)

12.66 KSRB 11-18.7.2 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 100x100x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 470.00
materials, labour, testing complete as per specifications. Specification No.
KBS 11-1.10 (PWD SR2009-10/P.No.72/12.66)

12.67 KSRB 11-18.7.3 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 75x75x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 430.00
materials, labour, testing complete as per specifications. Specification No.
KBS 11-1.10 (PWD SR2009-10/P.No.72/12.67)

12.68 KSRB 11-18.8.1 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 100x100x100x100mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 590.00
KBS 11-1.10 (PWD SR2009-10/P.No.72/12.68)

12.69 KSRB 11-18.8.2 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 75x75x75x75mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 540.00
KBS 11-1.10 (PWD SR2009-10/P.No.72/12.69)

12.70 KSRB 11-18.8.3 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 50x50x50x50mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 420.00
KBS 11-1.10 (PWD SR2009-10/P.No.72/12.70)

12.71 KSRB 11-18.9.1 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 100x100x100mm,
including cost of materials, labour, testing complete as per specifications. Each 550.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.72/12.71)
12.72 KSRB 11-18.10.1 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 100x100x75x75mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 510.00
KBS 11-1.10 (PWD SR2009-10/P.No.72/12.72)

12.73 KSRB 11-18.11.1 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 100x100x75mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 470.00
(PWD SR2009-10/P.No.73/12.73)

12.74 KSRB 11-18.11.2 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 100x100x50mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 400.00
(PWD SR2009-10/P.No.73/12.74)

12.75 KSRB 11-18.11.3 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 75x75x50mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 350.00
(PWD SR2009-10/P.No.73/12.75)

12.76 KSRB 11-18.12.1 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 100x100x100x100mm,
including cost of materials, labour, testing complete as per specifications. Each 570.00
KBS 11.1.10 (PWD SR2009-10/P.No.73/12.76)

12.77 KSRB 11-18.12.2 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 75x75x75x75mm, including
cost of materials, labour, testing complete as per specifications. KBS 11- Each 510.00
1.10 (PWD SR2009-10/P.No.73/12.77)

12.78 KSRB 11-18.12.3 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 50x50x50x50mm, including
cost of materials, labour, testing complete as per specifications. KBS 11- Each 450.00
1.10 (PWD SR2009-10/P.No.73/12.78)

12.79 KSRB 11-18.13.1 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 100x100x100x100mm,
including cost of materials, labour, testing complete as per specifications.
Specification No. KBS 11.1.10 (PWD SR2009-10/P.No.73/12.79) Each 550.00

12.80 KSRB 11-18.13.2 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 75x75x75x75mm, including
cost of materials, labour, testing complete as per specifications. Each 490.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.73/12.80)

12.81 KSRB 11-18.13.3 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 50x50x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 440.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.73/12.81)

12.82 KSRB 11-18.14.1 : Providing and fixing sand cast iron soil waste double
unequal invert plain branches of required degree 100x100x75x75mm,
including cost of materials, labour, testing complete as per specifications. Each 550.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.83-73/12.82)
12.83 KSRB 11-18.14.2 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 75x75x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 430.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.73/12.83)

12.84 KSRB 11-18.15.1 : Providing and fixing sand cast iron soil waste single
unequal invert plain branches of required degree 100x100x75mm,
including cost of materials, labour, testing complete as per specifications. Each 470.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.74/12.84)

12.85 KSRB 11-18.15.2 : Providing and fixing sand cast iron soil waste single
unequal invert plain branches of required degree 75x75x50mm, including
cost of materials, labour, testing complete as per specifications. Each 350.00
Specification No. KBS 11-1.10 (PWD SR2009-10/P.No.74/12.85)

12.86 KSRB 11-18.16.1 : Providing and fixing sand cast iron soil waste 152mm
offsets for 100mm pipes, including cost of materials, labour, testing
complete as per specifications. Specification No. KBS 11-1.10 (PWD Each 225.00
SR2009-10/P.No.74/12.86)

12.87 KSRB 11-18.16.2 : Providing and fixing sand cast iron soil waste 114mm
offsets for 75mm pipes, including cost of materials, labour, testing
complete as per specifications. Specification No. KBS 11-1.10 (PWD Each 190.00
SR2009-10/P.No.74/12.87)

12.88 KSRB 11-18.16.3 : Providing and fixing sand cast iron soil waste 230mm
offsets for 75mm pipes, including cost of materials, labour, testing
complete as per specifications. Specification No. KBS 11-1.10 (PWD Each 265.00
SR2009-10/P.No.74/12.88)

12.89 KSRB 11-18.17.1 : Providing and fixing sand cast iron trap of 100mm dia,
of self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing complete as per specifications. Specification No. Each 270.00
KBS 11-1.10 (PWD SR2009-10/P.No.74/12.89)

12.90 KSRB 11-18.17.2 : Providing and fixing sand cast iron trap of 75mm dia, of
self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing complete as per specifications. Specification No. Each 235.00
KBS 11-1.10 (PWD SR2009-10/P.No.74/12.90)

12.91 KSRB 11-18.17.3 : Providing and fixing sand cast iron trap of 50mm dia, of
self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing complete as per specifications. Specification No. Each 215.00
KBS 11-1.10 (PWD SR2009-10/P.No.74/12.91)

12.92 KSRB 11-18.18.1 : Providing lead caulked joints to sand cast iron/cast iron
(spun) pipes and fittings of 100mm dia, including cost of materials, labour,
testing complete as per specifications. specification No.KBS 13-2.7 (PWD Joint 81.00
SR2009-10/P.No.74/12.92)
12.93 KSRB 11-18.18.2 : Providing lead caulked joints to sand cast iron/cast iron
(spun) pipes and fittings of 75 mm dia, including cost of materials, labour,
testing complete as per specifications. specification No.KBS 13-2.7 (PWD Joint 70.00
SR2009-10/P.No.74/12.93)

12.94 KSRB 11-18.18.3 : Providing lead caulked joints to sand cast iron/cast iron
(spun) pipes and fittings of 50 mm dia, including cost of materials, labour,
testing complete as per specifications. specification No.KBS 13-2.7 (PWD Joint 60.00
SR2009-10/P.No.75/12.94)

12.95 KSRB 11-18.9.2 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 75x75x75mm, including
cost of materials, labour, testing complete as per specifications. Each 465.00
specification No.KBS 11.1.10 (PWD SR2009-10/P.No.75/12.95)

12.96 KSRB 11-18.9.3 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 50x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 420.00
specification No.KBS 11.1.10 (PWD SR2009-10/P.No.75/12.96)

12.97 KSRB 11-18.10.2 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 100x100x50x50mm, including cost of
materials, labour, testing complete as per specifications. specification Each 440.00
No.KBS 11.1.10 (PWD SR2009-10/P.No.75/12.97)

12.98 KSRB 11-18.10.3 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 75x75x50x50mm, including cost of
materials, labour, testing complete as per specifications. specification Each 425.00
No.KBS 11.1.10 (PWD SR2009-10/P.No.75/12.98)

12.99 KSRB 11-18.19.1 : Providing and fixing M.S. stays and clamps for sand
cast iron pipes of 100mm dia including cost of materials, labour complete
as per specifications. (PWD SR2009-10/P.No.75/12.99) No. 140.00

12.100 KSRB 11-18.19.2 : Providing and fixing M.S. stays and clamps for sand
cast iron pipes of 75mm dia including cost of materials, labour complete as
per specifications. (PWD SR2009-10/P.No.75/12.100) No. 135.00

12.101 KSRB 11-18.19.3 : Providing and fixing M.S. stays and clamps for sand
cast iron pipes of 50mm dia including cost of materials, labour complete as
per specifications. (PWD SR2009-10/P.No.75/12.101) No. 54.00

12.103 Providing (China clay) glzed foot rests of approved 1st quality and make
conforming to ISI Specifications and fixing in CM (1:3) as directed (Rate
includes cost of materials and conveyance to work spot).PWD SR2009-10/ Pair 150.00
P.No.75/12.103

12.104 Providing plastic seat with approved 1st quality and make conforming to
ISI specifications double flapped and fixing to English water closet with all
fittings (Rate includes cost of materials, fixtures and conveyance to work
spot.PWD SR2009-10/ P.No.75/12.104
12.104.1 Providing White plastic seat with approved 1st quality and make
conforming to ISI specifications double flapped and fixing to English water
closet with all fittings (Rate includes cost of materials, fixtures and Pair 250.00
conveyance to work spot.PWD SR2009-10/ P.No.75/12.104.1

12.104.2 Providing Black plastic seat with approved 1st quality and make
conforming to ISI specifications double flapped and fixing to English water
closet with all fittings (Rate includes cost of materials, fixtures and Pair 200.00
conveyance to work spot.PWD SR2009-10/ P.No.75/12.104.2

12.105 Providing 3 cms dia GI telescopic flush tank lever of approved 1st quality
and make conforming to ISI specifications and fixing in position as directed
by the Engineer. Rate includes cost of materials and conveyance to work Each 220.00
spot.PWD SR2009-10/ P.No.75/12.105

12.106 Providing vulcanizing or rubber float of approved st quality and make


conforming to ISI Specifications and fixing for low down cistern as directed
by the Engineer. Rate includes cost of materials and conveyance to work Each 167.00
spot. PWD SR2009-10/ P.No.76/12.106

12.107 Providing wash basin brackets of approved 1st quality and make
conforming to ISI Specifications and fixing for low down cistern as directed.
Rate includes cost of materials and conveyance to work spot.PWD Pair 207.00
SR2009-10/ P.No.76/12.107

12.108 Providing pedestal for wash basin of approved 1sty quality and make
coforming to ISI Specifications and fixing for low down cistern as directed.
Rate includes cost of materials and conveyance to work spot.PWD Each 835.00
SR2009-10/ P.No.76/12.108

12.109 Providing and fixing white vitreous china clay urinals with flat back of
approved make fixed to wooden plug including bends, painting white to
exposed pipes etc., complete as per directions. (rate includes cost of all Each 820.00
materials and lead). A grade.PWD SR2009-10/ P.No.76/12.109

12.110 Providing white vitreous china clay Indian pattern squatting urinals with
white glazed foot rests of approved quality and make conforming to ISI
Specifications and fixing in position with CC 1:2:4 as directed of size 50.8
cms X 38 cms X 10.16 cms- A Grade (Rate includes cost of all materials Each 920.00
and conveyance to work spot).PWD SR2009-10/ P.No.76/12.110

12.111 Providing and fixing 7.5 cms to 15.00 cms dia NP gating 100 mm dia.PWD
Each 145.00
SR2009-10/ P.No.76/12.111

12.112 Providing stonware gully trap of approved quality and make fixing in CC
1:2:4 and plastering with CM 1:3 wherever necessary. ( Rate includes cost
of all materials, fixtures and lead).PWD SR2009-10/ P.No.76/12.112

12.112.1 Providing stonware gully trap of size 10cms X 10cms approved quality
and make fixing in CC 1:2:4 and plastering with CM 1:3 wherever
necessary. ( Rate includes cost of all materials, fixtures and lead).PWD Each 175.00
SR2009-10/ P.No.76/12.112.1
12.112.2 Providing stonware gully trap of size 15cms X 10cms approved quality
and make fixing in CC 1:2:4 and plastering with CM 1:3 wherever
necessary. ( Rate includes cost of all materials, fixtures and lead).PWD Each 250.00
SR2009-10/ P.No.76/12.112.2

12.113 Providing and fixing CI Nahani trap of approved make conforming to ISI
Specifications and construction of cistern in CC 1:2:4 as per directions
( Rate is inclusive of cost materials and fixtures and conveyance of
materials to work spot).PWD SR2009-10/ P.No.76/12.113

12.113.1 Providing and fixing CI Nahani trap of size 10 cms X 7.5cms approved
make conforming to ISI Specifications and construction of cistern in CC
1:2:4 as per directions ( Rate is inclusive of cost materials and fixtures and Each 220.00
conveyance of materials to work spot).PWD SR2009-10/ P.No.76/12.113.1

12.113.2 Providing and fixing CI Nahani trap of size 12.5cms X 7.5cms approved
make conforming to ISI Specifications and construction of cistern in CC
1:2:4 as per directions ( Rate is inclusive of cost materials and fixtures and Each 270.00
conveyance of materials to work spot).PWD SR2009-10/ P.No.76/12.113.2

12.114 Clening the blockage of closets and soil pipes putting into working
order.PWD SR2009-10/ P.No.76/12.114

12.114.1 Clening the blockage of closets and soil pipes putting into working m 50.00
order.with Scaffolding PWD SR2009-10/ P.No.76/12.114.1

12.114.2 Clening the blockage of closets and soil pipes putting into working m 40.00
order.without Scaffolding PWD SR2009-10/ P.No.76/12.114.2

12.114.3 Clening the blockage of closets and soil pipes putting into working
order.underground Stoneware pipes PWD SR2009-10/ P.No.76/12.114.3 m 16.00

WATER SUPPLY WORK

13.1 KSRB 13-1.1: Providing and fixing to wall, ceiling and floor, galvanised /
mild steel tube 15mm dia nominal bore with fittings (medium grade weight
1.27 kg/mtr) B class including cost of all materials, labour charges, HOM of
equipments and testing complete as per specifications. Specification No. m 134.00
KBS 13.2.14/13.8 (PWD SR2009-10/P.No.78/13-1)

13.2 KSRB 13-1.2 : Providing and fixing to wall, ceiling and floor, galvanised /
mild steel tube 20mm dia nominal bore with fittings (medium grade weight
1.65 kg/mtr) B class including cost of all materials, labour charges, HOM of
equipments and testing complete as per specifications. Specification No. m 149.00
KBS 13.2.14/13.8 (PWD SR2009-10/P.No.78/13.2)

13.3 KSRB 13-1-3 : Providing and fixing to wall, ceiling and floor, galvanised /
mild steel tube 25mm dia nominal bore with fittings (medium grade weight
2.51 kg/mtr) B class including cost of all materials, labour charges, HOM of
equipments and testing complete as per specifications. Specification No. m 208.00
KBS 13.2.14/13.8 (PWD SR2009-10/P.No.78/13.3)
13.4 KSRB 13-1-4 : Providing and fixing to wall, ceiling and floor, galvanised /
mild steel tube 32mm dia nominal bore with fittings (medium grade weight
3.23 kg/mtr) B class including cost of all materials, labour charges, HOM of
equipments and testing complete as per specifications. Specification No. m 260.00
KBS 13.2.14/13.8 (PWD SR2009-10/P.No.78/13.4)

13.5 KSRB 13-1-5 : Providing and fixing to wall, ceiling and floor, galvanised /
mild steel tube 40mm dia nominal bore with fittings (medium grade weight
3.72 kg/mtr) B class including cost of all materials, labour charges, HOM of
equipments and testing complete as per specifications. Specification No. m 299.00
KBS 13.2.14/13.8 (PWD SR2009-10/P.No.78/13.5)

13.6 KSRB 13-1-6 : Providing and fixing to wall, ceiling and floor, galvanised /
mild steel tube 50mm dia nominal bore with fittings (medium grade weight
5.24 kg/mtr) B class including cost of all materials, labour charges, HOM of
equipments and testing complete as per specifications. Specification No. m 348.00
KBS 13.2.14/13.8 (PWD SR2009-10/P.No.78/13.6)

13.7 KSRB 13-2-1 : Extra for concealed pipe including painting with
anticorrosive bitumastic paint cutting chases, making good the concrete
surface, and plaster for 15mm dia nominal bore including cost of all
m 64.00
materials, labour charges, HOM of equipments complete as per
specifications. (PWD SR2009-10/P.No.78/13.7)

13.8 KSRB 13-2-2 : Extra for concealed pipe including painting with
anticorrosive bitumastic paint cutting chases, making good the concrete
surface, and plaster for 20mm dia nominal bore including cost of all m 64.00
materials, labour charges, HOM of equipments complete as per
specifications. (PWD SR2009-10/P.No.78/13.8)

13.9 KSRB 13-2-3 : Extra for concealed pipe including painting with
anticorrosive bitumastic paint cutting chases, making good the concrete
surface, and plaster for 25mm dia nominal bore including cost of all m 64.00
materials, labour charges, HOM of equipments complete as per
specifications. (PWD SR2009-10/P.No.78/13.9)

13.10 KSRB 13-3-1 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 15mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 114.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.78/13.10)

13.11 KSRB 13-3-2 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 20mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 128.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.78/13.11)
13.12 KSRB 13-3-3 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 25mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 187.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.78/13.12)

13.13 KSRB 13-3-4 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 32mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 232.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.78/13.13)

13.14 KSRB 13-3-5 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 40mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 265.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.78/13.14)

13.15 KSRB 13-3-6 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 50mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 305.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.78/13.15)

13.16 KSRB 13-3-7 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 65mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 455.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.79/13.16)

13.17 KSRB 13-3-8 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 80mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 595.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.79/13.17)

13.18 KSRB 13-3-9 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 100mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as m 735.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.79/13.18)

13.19 KSRB 13-3-10 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 150mm dia nominal bore with all fittings (earth work
in trenches to be measured and paid for separately) including cost of all
materials, labour charges, HOM of equipments and testing complete as
m 1260.00
per specifications. Specification No. KBS 13.2.14/13.6 (PWD SR2009-
10/P.No.79/13.19)
13.20 KSRB 13-4-1 : Making connection of G.I. distribution branch with G.I.
main of 25 to 40mm nominal bore, including cutting and threading the
pipes, providing and fixing Tee, nuts, labour for all item of works, testing
and HOM of equipments complete as per specifications. Specification No. Nos 248.00
KBS 13.2.14/13.10 (PWD SR2009-10/P.No.79/13.20)

13.21 KSRB 13-4-2 : Making connection of G.I. distribution branch with G.I. main
of 50 to 85mm and 100 to 150 nominal bore, including cutting and
threading the pipe, providing and fixing Tee, nuts, labour for all item of
works, testing and HOM of equipments complete as per specifications. Nos 390.00
Specification No. KBS 13.10 (PWD SR2009-10/P.No.79/13.21)

13.22 KSRB 13-5 : Providing and fixing water meter with stop cock, jam nut,
socket in G.I pipe line including cutting and threading the pipe and making
long screws including cost of all materials, labour, HOM of equipments
and testing complete as per specifications. Specification No. KBS Set 990.00
13.2.19/13.16 (PWD SR2009-10/P.No.79/13.22)

13.23 KSRB 13-6.1-1 : Providing and fixing in position brass bib cock of
approved quality 15mm nominal bore including cost of all materials,
labour, HOM of equipments with all leads complete as per specifications. Each 154.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.23)

13.24 KSRB 13-6.1-2 : Providing and fixing in position brass bib cock of
approved quality 20mm nominal bore including cost of all materials,
labour, HOM of equipments with all leads complete as per specifications. Each 178.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.24)

13.25 KSRB 13-6.1-3 : Providing and fixing in position brass bib cock of
approved quality 25mm nominal bore including cost of all materials,
labour, HOM of equipments with all leads complete as per specifications. Each 189.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.25)

13.26 KSRB 13-6.2-1 : Providing and fixing in position brass stop cock of
approved quality 15mm nominal bore including cost of all materials,
labour, HOM of equipments with all leads complete as per specifications. Each 128.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.26)

13.27 KSRB 13-6.2-2 : Providing and fixing in position brass stop cock of
approved quality 20mm nominal bore including cost of all materials, labour,
HOM of equipments with all leads complete as per specifications. Each 127.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.27)

13.28 KSRB 13-6.2-3 : Providing and fixing in position brass stop cock of
approved quality 25mm nominal bore including cost of all materials, labour,
HOM of equipments with all leads complete as per specifications. Each 126.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.28)
13.29 KSRB 13-6.2-4 : Providing and fixing in position brass stop cock of
approved quality 32mm nominal bore including cost of all materials, labour,
HOM of equipments with all leads complete as per specifications. Each 126.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.29)

13.30 KSRB 13-6.2-5 : Providing and fixing in position brass stop cock of
approved quality 40mm nominal bore including cost of all materials, labour,
HOM of equipments with all leads complete as per specifications. Each 126.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.30)

13.31 KSRB 13-6.2-6 : Providing and fixing in position brass stop cock of
approved quality 50mm nominal bore including cost of all materials, labour,
HOM of equipments with all leads complete as per specifications. Each 124.00
Specification No. KBS 13.2.2/13.3 (PWD SR2009-10/P.No.79/13.31)

13.32 KSRB 13-6.3-1 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 15mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 243.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.79/13.32)

13.33 KSRB 13-6.3-2 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 20mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 330.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.79/13.33)

13.34 KSRB 13-6.3-3 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 25mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 428.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.80/13.34)

13.35 KSRB 13-6.3-4 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 32mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 575.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.80/13.35)

13.36 KSRB 13-6.3-5 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 40mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 710.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.80/13.36)

13.37 KSRB 13-6.3-6 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 50mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 1065.00
as per specifications. 80/13.37)

13.38 KSRB 13-6.3-7 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 65mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 1985.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.80/13.38)
13.39 KSRB 13-6.3-8 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 80mm nominal bore including
cost of all materials, labour, HOM of equipments with all leads complete Each 2375.00
as per specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2009-
10/P.No.80/13.39)

13.40 KSRB 13-6.4-1 : Providing and fixing in position brass ball valve high or
low pressure with plastic float of approved quality 15mm nominal bore
including cost of all materials, labour and HOM of equipments with all Each 242.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.40)

13.41 KSRB 13-6.4-2 : Providing and fixing in position brass ball valve high or
low pressure with plastic float of approved quality 20mm nominal bore
including cost of all materials, labour and HOM of equipments with all Each 395.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.41)

13.42 KSRB 13-6.4-3 : Providing and fixing in position brass ball valve high or
low pressure with plastic float of approved quality 25mm nominal bore
including cost of all materials, labour and HOM of equipments with all Each 525.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.42)

13.43 KSRB 13-6.5-1 : Providing and fixing in position 15mm nominal bore brass
ferrule with C.I. mouth cover including boring and tapping the main, cost of
all materials, labour and HOM of equipments with all leads complete as
per specifications. Specification No. KBS 13.2.3/13.14 (PWD SR2009- Each 158.00
10/P.No.80/13.43)

13.44 KSRB 13-6.5-2 : Providing and fixing in position 20mm nominal bore brass
ferrule with C.I. mouth cover including boring and tapping the main, cost of
all materials, labour and HOM of equipments with all leads complete as
per specifications. Specification No. KBS 13.2.3/13.14 (PWD SR2009- Each 190.00
10/P.No.80/13.44)

13.45 KSRB 13-6.5-3 : Providing and fixing in position 25mm nominal bore brass
ferrule with C.I. mouth cover including boring and tapping the main, cost of
all materials, labour and HOM of equipments with all leads complete as
per specifications. Specification No. KBS 13.2.3/13.14 (PWD SR2009- Each 227.00
10/P.No.80/13.45)

13.46 KSRB 13-6.6-1 : Providing and fixing unplasticised PVC connection pipe
with brass union 15mm nominal bore 300 mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 295.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.46)

13.47 KSRB 13-6.6-2 : Providing and fixing unplasticised PVC connection pipe
with brass union 15mm nominal bore 450 mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 350.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.47)
13.48 KSRB 13-6.6-3 : Providing and fixing unplasticised PVC connection pipe
with brass union 20mm nominal bore 300 mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 302.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.48)

13.49 KSRB 13-6.6-4 : Providing and fixing unplasticised PVC connection pipe
with brass union 20mm nominal bore 450 mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 325.00
leads complete as per specifications. (PWD SR2009-10/P.No.80/13.49)

13.50 KSRB 13-6.7-1 : Providing and fixing in position chromium plated brass
shower rose with 15 or 20mm inlet 100mm dia including cost of all
materials, labour and HOM of equipments with all leads complete as per Each 495.00
specifications. Specification No. KBS 13.2.16/13.3(PWD SR2009-
10/P.No.80/13.50)

13.51 KSRB 13-6.7-2 : Providing and fixing in position chromium plated brass
shower rose with 15 or 20mm inlet 150mm dia including cost of all
materials, labour and HOM of equipments with all leads complete as per Each 540.00
specifications. Specification No. KBS 13.2.16/13.3 (PWD SR2009-
10/P.No.80/13.51)

13.52 KSRB 13-7.1.1 : Providing and fixing in position 25mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Nos. 450.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.80/13.52)

13.53 KSRB 13-7.1.2 : Providing and fixing in position 32mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Nos. 570.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.80/13.53)

13.54 KSRB 13-7.1.3 : Providing and fixing in position 40mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Each 620.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.80/13.54)

13.55 KSRB 13-7.1.4 : Providing and fixing in position 50mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Nos. 880.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.80/13.55)

13.56 KSRB 13-7.1.5 : Providing and fixing in position 65mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Nos. 935.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.80/13.56)

13.57 KSRB 13-7.1.6 : Providing and fixing in position 80mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Nos. 980.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.80/13.57)
13.58 KSRB 13-7.1.7 : Providing and fixing in position 100mm nominal bore gun
metal non-return valve horzontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as Nos. 1100.00
per specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.58)

13.59 KSRB 13-7.2.1 : Providing and fixing in position 25mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 380.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.59)

13.60 KSRB 13-7.2.2 : Providing and fixing in position 32mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 500.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.60)

13.61 KSRB 13-7.2.3 : Providing and fixing in position 40mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 625.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.61)

13.62 KSRB 13-7.2.4 : Providing and fixing in position 50mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 745.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.62)

13.63 KSRB 13-7.2.5 : Providing and fixing in position 65mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 840.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.63)

13.64 KSRB 13-7.2.6 : Providing and fixing in position 80mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 985.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.64)

13.65 KSRB 13-7.2.7 : Providing and fixing in position 100mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos. 1020.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2009-
10/P.No.81/13.65)

13.66 KSRB 13-8.1 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 20mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 64.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.66)
13.67 KSRB 13-8.2 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 25mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 77.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.67)

13.68 KSRB 13-8.3 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 84.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.68)

13.69 KSRB 13-8.4 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 40mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 92.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.69)

13.70 KSRB 13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 118.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.70)

13.70.1 KSRB 13-8.6 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 63mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.70.1)

13.70.2 KSRB 13-8.7 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-10/P.No.81/13.70.2)

13.70.3 KSRB 13-8.8 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-
10/P.No.81/13.70.2.3)
13.70.4 KSRB 13-8.9 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-
10/P.No.82/13.70.2.4)

13.70.5 KSRB 13-8.10: Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 140mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-
10/P.No.82/13.70.2.5)

13.70.6 KSRB 13-8.11: Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 160mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.1/13.9 (PWD SR2009-
10/P.No.82/13.70.2.6)

13.71 KSRB 13-9.1 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 103.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.71)

13.72 KSRB 13-9.2 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 40mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 118.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.72)

13.73 KSRB 13-9.3 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 125.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73)

13.73.1 KSRB 13-9.4: Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 63mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 318.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73.1)
13.73.2 KSRB 13-9.5: Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 380.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73.2)

13.73.3 KSRB 13-9.6: Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 455.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73.3)

13.73.4 KSRB 13-9.7: Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 555.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73.4)

13.73.5 KSRB 13-9.8: Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 140mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 705.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73.5)

13.73.6 KSRB 13-9.9: Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 160mm out side
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour
m 810.00
charges, HOM of equipments and testing complete as per specifications.
Specification No. KBS 13.2.15.2/13.9 (PWD SR2009-10/P.No.82/13.73.6)

13.74 KSRB 13-10.1 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 16mm out side diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor including cost of all materials,
labour charges, HOM of equipments and testing complete as per m 77.00
specifications. Specification No. KBS 13.2.15.4/13.9 (PWD SR2009-
10/P.No.82/13.74)

13.75 KSRB 13-10.2 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 20mm out side diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor including cost of all materials,
labour charges, HOM of equipments and testing complete as per m 84.00
specifications. Specification No. KBS 13.2.15.4/13.9 (PWD SR2009-
10/P.No.82/13.75)
13.76 KSRB 13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 25mm out side diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor including cost of all materials,
labour charges, HOM of equipments and testing complete as per m 103.00
specifications. Specification No. KBS 13.2.15.4/13.9 (PWD SR2009-
10/P.No.82/13.76)

13.77 KSRB 13-10.4 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 32mm out side diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor including cost of all materials,
labour charges, HOM of equipments and testing complete as per m 129.00
specifications. Specification No. KBS 13.2.15.4/13.9 (PWD SR2009-
10/P.No.82/13.77)

13.78 KSRB 13-11.1 : Providing and placing on terrace, polyethylene water


storage tanks with manhole lid and suitable locking arrangements, making
holes of suitable diameter for inlet, outlet and over flow pipes, including
cost of all materials, labour, transport charges, HOM of equipments and Nos 6980.00
testing complete as per specifications. (For 1000 litre capacity)
Specification No. KBS 13.22 (PWD SR2009-10/P.No.82/13.78)

13.79 Providing and fixing gun metal wheel valve conforming to IS specification
of approved make as per directions including all lead and lift etc.,
complete.(PWD SR2009-10/P.No.82/13.79)

13.79.1 Providing and fixing for 15mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift Each 265.00
etc., complete.(PWD SR2009-10/P.No.82/13.79.1)

13.79.2 Providing and fixing for 20mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift
etc., complete.(PWD SR2009-10/P.No.83/13.79.2) Each 330.00

13.79.3 Providing and fixing for 25mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift
etc., complete.(PWD SR2009-10/P.No.83/13.79.3) Each 460.00

13.79.4 Providing and fixing for 32mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift
etc., complete.(PWD SR2009-10/P.No.83/13.79.4) Each 670.00

13.79.5 Providing and fixing for 40mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift Each 850.00
etc., complete.(PWD SR2009-10/P.No.83/13.79.5)

13.79.6 Providing and fixing for 50mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift Each 1300.00
etc., complete.(PWD SR2009-10/P.No.83/13.79.6)
13.80 Providing gun metal pillar ocks 15mm dia of I class conforming to ISI
Specifications and fixing them in position as per directions including of cost
of materials and fixtures and conveyance to spot.(PWD SR2009- Each 225.00
10/P.No.83/13.80)

13.81 Providing NP/CP waste unions conforming to ISI specifications and fixing
themin position as per directions including cost of materials, fixtures and
conveyance to work spot etc., complete.(PWD SR2009-10/P.No.83/13.81)

13.81.1 Providing NP/CP waste unions conforming to ISI specifications and fixing
for 32mm dia themin position as per directions including cost of materials,
fixtures and conveyance to work spot etc., complete.(PWD SR2009- Each 110.00
10/P.No.83/13.81.1)

13.81.2 Providing NP/CP waste unions conforming to ISI specifications and fixing
for 40mm dia themin position as per directions including cost of materials,
Each 140.00
fixtures and conveyance to work spot etc., complete.(PWD SR2009-
10/P.No.83/13.81.2)

13.81.3 Providing NP/CP waste unions conforming to ISI specifications and fixing
for 50mm dia themin position as per directions including cost of materials,
fixtures and conveyance to work spot etc., complete.(PWD SR2009- Each 190.00
10/P.No.83/13.81.3)

13.82 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)


composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. ( Internal work) (PWD SR2009-
10/P.No.94/13.82)

Pipes exposed on wall


13.82.1 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)
composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with m 175.00
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. 1216 (16 mm OD) pipe (PWD
SR2009-10/P.No.83/13.82.1)

13.82.2 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)


composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever m 220.00
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. 1620 (20mm OD) pipe (PWD
SR2009-10/P.No.83/13.82.2)
13.82.3 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)
composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever m 280.00
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. 2025 (25mm OD) pipe (PWD
SR2009-10/P.No.83/13.82.3)

13.82.4 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)


composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with m 350.00
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. 2532 (32 mm OD) pipe (PWD
SR2009-10/P.No.83/13.82.4)

13.82.5 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)


composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever m 500.00
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. 3240 (40mm OD) pipe (PWD
SR2009-10/P.No.83/13.82.5)

13.82.6 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE)


composite pressure pipes conforming to IS 15450 duly "ISI" marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings (engineering plastic blend and brass inserts wherever
required.) e.g. elbows, tees, reducers, couplers & connectores etc., with m 650.00
clamps at 1.00 meter spacing, cutting & making good the wall etc.,
including testing complete as required. 4050 (50mm OD) pipe (PWD
SR2009-10/P.No.83/13.82.6)

13.83 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. (Internal work)
(PWD SR2009-10/P.No.83/13.83)

Concealed piping with cutting chases &


making good walls etc.,
13.83.1 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)
Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 210.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 1216 (16 mm
OD) pipe (PWD SR2009-10/P.No.84/13.83.1)

13.83.2 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 250.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 2025 (25 mm
OD) pipe (PWD SR2009-10/P.No.84/13.83.2)

13.83.3 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 300.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 2025 (25 mm
OD) pipe (PWD SR2009-10/P.No.84/13.83.3)

13.83.4 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 390.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 2532 (32 mm
OD) pipe (PWD SR2009-10/P.No.84/13.83.4)

13.83.5 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 510.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 3240 (40 mm
OD) pipe (PWD SR2009-10/P.No.84/13.83.5)
13.83.6 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)
Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 675.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 4050 (50mm
OD) pipe (PWD SR2009-10/P.No.84/13.83.6)

13.84 Providing & fixing Polyethelene-Aluminium- Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.
stablized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade incluiding all soecial
composite fittings (Engineering plastic blend and brass inserts wherever
requiored.) e.g. elbows, tees, reducers, couplers & connectors etc., with
tranching & refilling upto 1.00 meter depth including testiong complete as
required. (External work) (PWD SR2009-10/P.No.84/13.84))

Pipe in trenches including excavation &


refilling etc.,
13.84.1 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)
Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 150.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 1216 (16 mm
OD) pipe (PWD SR2009-10/P.No.84/13.84.1)

13.84.2 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 200.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 1620 (20 mm
OD) pipe (PWD SR2009-10/P.No.84/13.84.2)

13.84.3 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 250.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 2025 (25mm
OD) pipe (PWD SR2009-10/P.No.84/13.84.3)
13.84.4 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)
Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 320.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 2532 (32 mm
OD) pipe ((PWD SR2009-10/P.No.84/13.84.4)

13.84.5 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with
m 420.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 3240 (40 mm
OD) pipe (PWD SR2009-10/P.No.84/13.84.5)

13.84.6 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE)


Composote pressure Pipes conforming to IS 15450 duly "ISI" marked,
U.V.stabalized with Carbon black for hot & cold water supply, capable to
withstand temparature upto 80 degree centigrade including all special
composite fittings ( Engineering plastic blend and brass inserts wherever
required.) e.g.elbows, tees, reducers, couplers & connectors etc., with m 520.00
cement taking at 1.00 meter spacing, and every fitting, cutting & making
good the walls etc., including testing complete as required. 4050 (50 mm
OD) pipe (PWD SR2009-10/P.No.84/13.84.6)

13.85 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and testing of joints complete.
(internal work exposed on wall) PWD SR 2009-10/ P.No.84/13.85)

13.85.1 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and 95.00
fittings with one step CPCV solvent cement and testing of joints complete.
(internal work exposed on wall) 15mm nominal OD pipes PWD SR 2009-
10/ P.No.84/13.85.1)

13.85.2 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
110.00
fittings with one step CPCV solvent cement and testing of joints complete.
(internal work exposed on wall) 20 mm nominal OD pipes PWD SR 2009-
10/ P.No.84/13.85.1)
13.85.3 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and testing of joints complete. 140.00
(internal work exposed on wall) 25 mm nominal OD pipes PWD SR 2009-
10/ P.No.84/13.85.1)

13.85.4 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and 190.00
fittings with one step CPCV solvent cement and testing of joints complete.
(internal work exposed on wall) 32 mm nominal OD pipes PWD SR 2009-
10/ P.No.84/13.85.1)

13.85.5 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and 270.00
fittings with one step CPCV solvent cement and testing of joints complete.
(internal work exposed on wall) 40 mm nominal OD pipes PWD SR 2009-
10/ P.No.84/13.85.1)

13.85.6 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and 400.00
fittings with one step CPCV solvent cement and testing of joints complete.
(internal work exposed on wall) 50 mm nominal OD pipes PWD SR 2009-
10/ P.No.84/13.85.1)

13.86 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and the cost of cutting chases
& making good the same including testing of joints complete.(concealed
work including cutting chases and good the walls etc.,) PWD SR 2009-10/
P.No.84-85/13.86)

13.86.1 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and the cost of cutting chases m 110.00
& making good the same including testing of joints complete.(concealed
work including cutting chases and good the walls etc.,) 15 mm nominal
OD pipes PWD SR 2009-10/ P.No.84-85/13.86)

13.86.2 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and the cost of cutting chases m 170.00
& making good the same including testing of joints complete.(concealed
work including cutting chases and good the walls etc.,) 20 mm nominal
OD pipes PWD SR 2009-10/ P.No.84-85/13.86)
13.86.3 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and the cost of cutting chases
m 210.00
& making good the same including testing of joints complete.(concealed
work including cutting chases and good the walls etc.,) 25 mm nominal
OD pipes PWD SR 2009-10/ P.No.84-85/13.86)

13.86.4 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPCV solvent cement and the cost of cutting chases m 260.00
& making good the same including testing of joints complete.(concealed
work including cutting chases and good the walls etc.,) 32 mm nominal
OD pipes PWD SR 2009-10/ P.No.84-85/13.86)

13.87 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching,
refilling & testing of joints complete. PWD SR 2009-10/ P.No.84-
85/13.87)

13.87.1 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 90.00
refilling & testing of joints complete. 15mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.1)

13.87.2 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 100.00
refilling & testing of joints complete. 20mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)

13.87.3 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 135.00
refilling & testing of joints complete. 25mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)

13.87.4 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 175.00
refilling & testing of joints complete. 32mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)

13.87.5 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 240.00
refilling & testing of joints complete. 40mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)

13.87.6 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 380.00
refilling & testing of joints complete. 50mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)
13.87.7 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 1200.00
refilling & testing of joints complete. 62.50mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)

13.87.8 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 1500.00
refilling & testing of joints complete. 75mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)
13.87.9 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 2100.00
refilling & testing of joints complete. 100mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)
13.87.10 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 3700.00
refilling & testing of joints complete. 150mm nominal OD pipes PWD SR
2009-10/ P.No.85/13.87.2)

FLOORING
14.1 KSRB 14.1: Providing and laying flooring with burnt stone slabs 10 cms
thick, rough chistle dressed on sand bed 7.5 cms to 8 cms thick and
pointed with cement mortar 1:3, including cost of materials, labour, curing Sqm 620.00
complete as per specifications. Specification No. KBS 14.26 (PWD
SR2009-10/P.No. 87/14.1)

14.2 KSRB 14.2: Providing and laying flooring with burnt stone slabs 10 cms
thick, rough chistle dressed on cement mortar bed 1:6, 25mm thick, and
pointed with cement mortar 1:3, including cost of materials, labour, curing Sqm 630.00
complete as per specifications. Specification No. KBS 14.26 (PWD
SR2009-10/P.No.87/14.2)

14.3 KSRB 14.3: Providing and laying flooring and steps machine cut granite
slabs 40mm thick on cement mortar bed 1:6, 25mm thick, and pointed
with cement mortar bed 1:3 over existing cement concrete bed, including
cost of materials, labour, curing complete as per specifications. Sqm 1610.00
Specification No. KBS 14.26 (PWD SR2009-10/P.No. 87/14.3)

14.4 KSRB 14.4: Providing and laying flooring and steps fine dressed granite
stone slabs 40mm thick on cement mortar bed 1:6, 25mm thick, and
pointed with cement mortar bed 1:3 over existing cement concrete bed,
including cost of materials, labour, curing complete as per specifications. Sqm 1875.00
Specification No. KBS 14.26 (PWD SR2009-10/P.No. 87/14.4)

14.5 KSRB 14.5: Providing and laying flooring and steps fine machine polished
granite stone slabs black / natural/ green / pink colour 20mm thick on
cement mortar bed 1:6, 20mm thick, and joints finished with cement mortar
bed 1:3 over existing cement concrete bed, including cost of materials, Sqm 1350.00
labour, curing complete as per specifications. Specification No. KBS 14.26
(PWD SR2009-10/P.No. 87/14.5)
14.6 KSRB 14-6.1: Providing and laying heavy duty cobble stones 60mm
thick interlock pavers, using cement and course sand for manufacture of
blocks of approved size, shape and colour with a minimum compressive
strength of 281 kg per sqm over 50mm thick sand bed (average thickness)
and compacting with plate vibrator having 3 tons compaction force thereby Sqm 590.00
forcing part of sand underneath to come up in between joints, final
compaction of pavar surface joints into its final level, including cost of
materials, labour and HOM of machineries complete as per specifications.
(PWD SR2009-10/P.No. 87/14.6)

14.7 KSRB 14-6.2: Providing and laying heavy duty cobble stones 75mm
thick interlock pavers, using cement and course sand for manufacture of
blocks of approved size, shape and colour with a minimum compressive
strength of 281 kg per sqm over 50mm thick sand bed (average thickness)
and compacting with plate vibrator having 3 tons compaction force thereby
Sqm 680.00
forcing part of sand underneath to come up in between joints, final
compaction of pavar surface joints into its final level, including cost of
materials, labour and HOM of machineries complete as per specifications.
(PWD SR2009-10/P.No.87/14.7)

14.8 KSRB 14-7.1: Providing and laying flooring with 1:2:4 cement concrete, 40
mm thick Sqm 150.09 using broken granite metal of 20 mm and down size
laid to line and level in one layer and finish with a floating coat of neat
cement, including cost of materials, labour, curing complete as per Sqm 200.00
specifications. Specification No. KBS 14.3 (PWD SR2009-
10/P.No.87/14.8)

14.9 KSRB 14-7.2: Providing and laying red oxide flooring 40mm thick, with an
under layer of 30mm thick 1:2:4 cement concrete, using broken granite
metal of 12.5mm nominal size and top layer of 10mm thick plaster with 1:3
cement mortar mixed with red of oxide (using 3.5 kg of red oxide per 50
kg of cement) finished with floating coat of neat cement mixed with red Sqm 380.00
oxide (mix of same proportion), including cost of materials, labour, curing,
complete as per specifications. Specification No.KBS 14.3 (PWD SR2009-
10/P.No.88/14.9)

14.10 KSRB 14-7.3: Providing and laying flooring 40mm thick, with an imder
layer of 30mm thick 1:2:4 cement concrete, using broken granite metal of
12.5mm nominal size and top layer of 10mm thick plaster with cement
mortar 1:3, finished with floating cost of neal cement including cost of Sqm 300.00
materials, labour, curing, complete as per specifications. Specification
No.KBS 14.3 (PWD SR2009-10/P.No. 88/14.10)

14.11 KSRB 14-7.4: Extra for making chequers of approved pattern on cement
concrete floor, steps, landings, pavements, including cost of labour
complete as per specifications. (PWD SR2009-10/P.No. 88/14.11) Sqm 12.00

14.12 KSRB 14-8.1: Providing and laying linolium covering to floors plain or
coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub
floor stretching, cutting and fixing complete, including cost of materials, Sqm 370.00
labour, complete as per specifications. Specification No. KBS 14.37.7
(PWD SR2009-10/P.No. 88/14.12)
14.13 KSRB 14-9.1: Providing and laying 1:2:4 cement concrete flooring 50 mm
thick with metallic concrete hardner toping, under layer of 35 mm thick
1:2:4 cement concrete using broken granite metal of 20mm and down size,
and top layer 50mm thick of metallic cement hardner consisting of mix 1:2
(1 cement hardner mix : 2 granite metal 10mm nominal size) by volume,
with which metallic hardening compound of approved quality mix in the
ratio of 4:1 (4 part of cement and 1 part of metallic floor hardening Sqm 735.00
compound of approved quality by wt), including finishing cost of materials,
labour, curing complete as per specification.Specification No. KBS 14.4
(PWD SR2009-10/P.No. 88/14.13)

14.14 KSRB 14-9.2: Providing and laying 1:2:4 cement concrete flooring 60mm
with metallic concrete hardner toping, under layer of 45 mm thick 1:2:4
cement concrete using broken granite metal of 20mm and down size, and
top layer 15mm thick of metallic cement hardner consisting of mix 1:2 (1
cement hardner mix : 2 granite metal 10mm nominal size) by volume, with
metallic hardening compound of approved quality mix in the ratio of 4:1 (4
Sqm 790.00
part of cement = 1 part of metallic floor hardening compound of approved
quality by wt), including finishing cost of materials, labour, curing complete
as per specification.Specification No. KBS 14.4 (PWD SR2009-10/P.No.
88/14.14)

14.15 KSRB 14-10.1: Flooring with 25mm to 40mm thick polished tandur blue
stone slabs using cement mortar 1:6, 25mm thick over existing cement
concrete bed of top of roof laid to line and level and joined with cement
slurry mixed with pigment to match the shade of the slab, including cost of Sqm 730.00
materials, labour, curing, polishing complete as per specifications. (PWD
SR2009-10/P.No. 88-89/14.15)

14.16 KSRB 14-10.2: Flooring with 25mm to 40mm thick polished shahabad
slabs using cement mortar 1:6, 25mm thick over existing cement concrete
bed of top of roof laid to line and level and joined with cement slurry mixed
with pigment to match the shade of the slab, including cost of materials, Sqm 680.00
labour, curing, polishing complete as per specifications. (PWD SR2009-
10/P.No.89/14.16)

14.17 KSRB 14-10.3: Providing flooring with 25mm to 40mm thick polished
Cadappa slabs using cement mortar 1:6, 25mm thick over existing
cement concrete bed of top of roof laid to line and level and joined with
cement slurry mixed with pigment to match the shade of the slab, including Sqm 700.00
cost of materials, labour, curing, polishing complete as per specifications.
(PWD SR2009-10/P.No. 89/14.17)

14.18 KSRB 14-11.1: Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with dark shade pigment
with ordinary cement in top layer only using while, black, chacolate, yellow
or baroda green marble chips of size from 7 to 10 nominal size laid in
cement marble powder mix 3:1 (3 cement : 1 marble powder by weight) in
Sqm 800.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) curing polishing oxalic acid wash, wax polish, including cost of
materials, labour, curing, polishing complete as per specifications.
Specification No. KBS 14.8 (PWD SR2009-10/P.No. 89/14.18)
14.19 KSRB 14-11.2: Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with light shade pigment
with white cement in top layer only using while, black, chacolate, yellow or
baroda green marble chips of size from 7 to 10 nominal size laid in cement
marble stone mixed 3:1 (3 cement : 1 marble powder by weight) in Sqm 970.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) curing polishing oxalic acid wash, wax polish, including cost of
materials, labour, complete as per specifications. Specification No. KBS
14.8 (PWD SR2009-10/P.No. 89/14.19)

14.20 KSRB 14-11.3 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with medium shade
pigment with approximately 50% white cement and 50% ordinary cement
in top layer only using white, black, chacolate, yellow or baroda green
marble chips of size from 7 to 10 nominal size laid in cement marble stone
mixed 3:1 (3 cement : 1 marble powder by weight) in proportion of 4:7 (4 Sqm 870.00
cement marble powder mix : 7 marble chips by volume) curing polishing
oxalic acid wash, wax polish, including cost of materials, labour, complete
as per specifications. Specification No. KBS 14.8 (PWD SR2009-10/P.No.
89/14.20)

14.21 KSRB 14-11.4 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with white cement without
any pigment in top layer only using white, black, chacolate, yellow or
baroda green marble chips of size from 7 to 10 nominal size laid in cement
marble stone mixed 3:1 (3 cement : 1 marble powder by weight) in Sqm 880.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) curing polishing oxalic acid wash, wax polish, including cost of
materials, labour, complete as per specifications. Specification No. KBS
14.8 (PWD SR2009-10/P.No. 90/14.21)

14.22 KSRB 14-11.5 : Extra for providing and fixing aluminium strips 40 mm wide
and 1.5 mm thick painted with a protective coat of bitumen for joints of
mosaic floors, including cost of materials, labour, curing, complete as per m 23.00
specification (PWD SR2009-10/P.No.90/14.22)

14.23 KSRB 14-11.6 : Extra for providing and fixing glass strips 40 mm wide and
4mm thick for joints of mosaic floors, including cost of materials, labour,
curing, complete as per specifications. (PWD SR2009-10/P.No. 90/14.23) m 20.00

14.24 KSRB 14-12.1: Providing mosaic tiles flooring with precast gret colour
mosaic tiles 20mm thick using marble chips of approved colour 7 to 10
nominal size laid in floors and landings on a bed of 25mm thick cement
mortar 1:6, mix, jointed with neat cement slurry mix with pigment to match
the shade of tiles curing, rubbing, polishing, oxalic acid wash, wax polish,
Sqm 480.00
including cost of materials, labour, HOM of machinary complete as per
specifications. Specification No. KBS 14.11 (PWD SR2009-10/P.No.
90/14.24)
14.25 KSRB 14-12.2: Providing mosaic tiles flooring with precast light shade
pigment with white cement mosaic tiles 20mm thick using marble chips of
approved colour 7 to 10 nominal size laid in floors and landings on a bed
of 25mm thick cement mortar 1:6, mix, jointed with neat cement slurry mix
with pigment to match the shade of tiles curing, rubbing, polishing, oxalic
Sqm 640.00
acid wash, wax polish, including cost of materials, labour, HOM of
machinary complete as per specifications. Specification No. KBS 14.11
(PWD SR2009-10/P.No. 90/14.25)

14.26 KSRB 14-12.3 : Providing mosaic tiles flooring with precast medium shade
pigment using 50% white cement and 50% ordinary cement mosaic tiles
20mm thick using marble chips of approved colour 7 to 10 nominal size
laid in floors and landings on a bed of 25mm thick average thickness of
cement mortar 1:6, mix, jointed with neat cement slurry mix with pigment
to match the shade of tiles curing, rubbing, polishing, oxalic acid wash, Sqm 560.00
wax polish, including cost of materials, labour, HOM of machinary
complete as per specifications. (PWD SR2009-10/P.No. 90-91/14.26)

14.27 KSRB 14-12.4 : Providing mosaic tiles flooring with white precast cement
mosaic tiles 20mm thick using marble chips of 7 to 10 nominal size laid in
floors and landings on a bed of 25 mm thick average thickness of cement
mortar 1:6, mix, jointed with neat cement slurry mix with pigment to match
the shade of tiles, curing, rubbing, polishing, oxalic acid wash, wax polish, Sqm 700.00
including cost of materials, labour, HOM of machinary complete as per
specifications. (PWD SR2009-10/P.No.91/14.27)

14.28 KSRB 14-13.1: Providing precast chequered mosaic tiles dark shade using
ordinary grey cement for steps and flooring, with precast 20mm thick,
using marble chips of 7 to 10 nominal size laid in floors, steps and landings
on a bed of 12mm thick cement mortar 1:3 mix, and jointed with neat
cement slurry mixed with pigment to match the shade of tiles, curing,
rubbing, polidhinh, oxslic acid wash, wax polish, including cost of Sqm 610.00
materials, labour complete as per specifications. (PWD SR2009-10/P.No.
91/14.28)

14.29 KSRB 14-13.2: Providing precast chequered mosaic tiles light shade using
white cement for steps and flooring, 20mm thick, using marble chips of 7 to
10 nominal size laid in floors, steps and landings on a bed of 12mm thick
cement mortar 1:3 mix, and jointed with neat cement slurry mixed with
pigment to match the shade of tiles curing, rubbing, polishing, oxalic acid Sqm 750.00
wash, wax polish, including cost of materials, labour, complete as per
specifications. Specification No. KBS 14.13, 14.14 (PWD SR2009-
10/P.No. 91/14.29)

14.30 KSRB 14-13.3: Providing precast chequered mosaic tiles medium shade
pigment using 50% white cement and 50% ordinary cement for steps and
flooring 20mm thick using marble chips of 7 to 10 nominal size laid on a
bed of 12mm thick cement mortar 1:3 mix, and jointed with neat cement
slurry mixed with pigment to match the shade of tiles curing, rubbing,
polishing, oxalic acid wash, wax polish, including cost of materials, labour, Sqm 670.00
complete as per specifications. Specification No. KBS 14.13, 14.14 (PWD
SR2009-10/P.No. 91/14.30)
14.31 KSRB 14-13.4: Providing precast chequered mosaic tiles white colour for
steps and Sqm 530.78 flooring, 20mm thick, using marble chips of 7 to 10
nominal size laid on a bed of 12mm thick cement mortar 1:3 mix, and
jointed with neat cement slurry mixed with pigment to match the shade of
tiles rubbing, polishing, oxalic acid wash, wax polish, including cost of Sqm 820.00
materials, labour, curing, complete as per specifications. Specification No.
KBS 14.13, 14.14 (PWD SR2009-10/P.No. 91/14.31)

14.32 KSRB 14-14.1: Providing white glazed tiles of sizes 10mm thick for
flooring, treads of steps and landings, laid on a bed of 12mm thick, cement
mortar 1:3 mix, finished with flush pointing using white cement, including Sqm 760.00
cost of materials, labour, curing, complete as per specifications. (PWD
SR2009-10/P.No. 102/14.32)

14.33 KSRB 14-14.2: Providing colour glazed tiles of size 15 cms x 15 cms
10mm thick for flooring, treads of steps and landings laid on a bed of
12mm thick, cement mortar 1:3 mix, flush pointing using white cement with
matching colour pigment, including cost of materials, labour, curing, Sqm 780.00
complete as per specifications. Specification No. KBS 14.15.2 (PWD
SR2009-10/P.No. 92/14.33)

14.34 KSRB 14-14.3: Providing white glazed tiles of size 15 cms x 15 cms 6mm
thick for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing using white cement with matching
colour pigment, including cost of materials, labour, curing, complete as per Sqm 680.00
specifications. Specification No. KBS 14.15.1 (PWD SR2009-10/P.No.
92/14.34)

14.35 KSRB 14.14.-4: Providing colour glazed tiles of size 15 cms x 15 cms 6mm
thick for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing using white cement with matching
colour pigment, including cost of materials, labour, curing, complete as per Sqm 670.00
specifications. Specification No. KBS 14.15.2 (PWD SR2009-10/P.No.
92/14.35)

14.36 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2009-10/P.No. 92/14.36.1)

14.36.1 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per Sqm 680.00
specifications. for Ceramic Tiles of size 15 x 15 cms (PWD SR2009-
10/P.No. 92/14.36.1)

14.36.2 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per Sqm 640.00
specifications. for Ceramic Tiles of size 30 x 30 cms (PWD SR2009-
10/P.No. 92/14.36.2)
14.37 KSRB 14-15.1: Providing marble slab flooring 20mm thick with edges of
slab machine cut, for flooring, treads of steps and landings laid on a bed of
25mm thick cement mortar 1:6, mix, to line and level, jointed with cement
slurry curing, rubbing, polishing complete finishling with flush pointing
using white cement, including cost of materials, HOM of machineries,
labour, curing, complete as per specifications. Note : While preparing Sqm 1700.00
analysis the quality of marble slab should be clearly noted namely white
marble, adanga marble, makrana etc., and also size of slab should be
noted clearly. Specification No. KBS 14.18 (PWD SR2009-10/P.No.
92/14.37)

14.38 KSRB 14-16.1 : Providing skirting upto 30 cms. height with cement mortar
1:3 finished with a floating coat of neat cement including rounding off
junctions floor, overall 15mm thick including cost of materials, labour, Sqm 150.00
complete as per specifications. Specification No. KBS 14.5 (PWD SR2009-
10/P.No. 92/14.38)

14.39 KSRB 14-16.2 : Providing red oxide skirting upto 30 cms. height with
cement mortar 1:3 including rounding off junctions with floor, finished
overall 15mm thick, top portion 5mm thickmixed with red oxide and a
floating coat of neat cement using 3.5kg of red oxide of iron per 50 kg of Sqm 176.00
cement including cost of materials, labour, complete as per specifications.
Specification No. KBS 14.5 (PWD SR2009-10/P.No. 92/14.39)

14.40 KSRB 14-17.1 : Providing skirting, dado, rises of steps with white glazed
tiles20 X 20cms 6mm thick on 10mm thick cement plaster 1:3 and
jointed with white cement slurry over rough plaster surface (excluding cost
of rough plastered surface which should be measured and paid separately)
using glazed tiles of approved make and size including cost of materials, Sqm 700.00
labour, complete as per specifications. Specification No. KBS 14.16, 14.17
(PWD SR2009-10/P.No. 93/14.40)

14.41 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed
tiles 20 X 20 cms 6mm thick on 10mm thick cement plaster 1:3 and jointed
with white cement slurry over rough plaster surface (excluding cost of
rough plastered surface which should be measured and paid separately)
using glazed tiles of approved make and size including cost of materials, Sqm 850.00
labour, complete as per specifications. Specification No. KBS 14.16, 17.17
(PWD SR2009-10/P.No. 93/14.41)

14.42 KSRB 14-18.1 : Providing skirting, dado, rises of steps with marble slabs
not exceeding 30 cms. height on 10 cms. thick cement mortar 1:3 and
jointed with white cement slurry over rough plaster surface (excluding cost
of rough plastered which should be measured and paid separately) using
marble slab with machine cut edges upto 25 cms. thick including cost of Sqm 1780.00
materials, labour, complete as per specifications. Specification No. KBS
14.19 (PWD SR2009-10/P.No. 93/14.42)

14.43 Providing and fixing Special make glazed Vitrified tiles (Granomite finish)
of approved make, quality and colour of size 600 x 600x10mm thick fixed
on existing flooring with a special roffe adhesive for flooring and skirting
etc., complete including providing spears at required interval and removing Sqm 1100.00
stains etc., complete. (PWD SR2009-10/P.No. 93/14.43)
14.44 Providing flooring with 60 cms x 60cms. size Vitrified glazed tiles of
approved quality & make, fixed on top of existing flooring fixed with
suitable adhesive, including cutting the tiles to the required size and fixing Sqm 1030.00
etc., complete. (PWD SR2009-10/P.No. 93/14.44)

14.45 Providing vitrified tiles 60 cms x 60 cms of approved make, shade and size
for flooring laid on a bed of 12 mm thick cement mortar 1:3 mix, flush
pointing with white cement using colour pigment, including cost of
Sqm 880.00
materials, labour, curing complete as per specifications. (PWD SR2009-
10/P.No. 93/14.45)

14.46 Providing and Laying pattern flooring for staircase treads and risers using
the combiantion of 20mm thick ruby red granite @ 66%, 20mm thick grey
granite @ 20%, 20 mm thick Shiva gold granite 7%, 20mm thick black
granite 7%. The granite meterials are laid on existing bed of CM 1:320 mm
thick pointed with colour pigment, including full rounding for nosing, Sqm 5440.00
flaming the ruby red granite for 50mm wide curing etc., complete (PWD
SR2009-10/P.No. 93/14.46)

14.47 Providing and Laying flooring using pre polished 19 mm thick water
cut/gang saw Granite slab over existing cement concrete bed in CM 1:4
average 20mm thick pointed with white cement/colour pigment etc.,
complete. (PWD SR2009-10/P.No. 93/14.47)

14.47.1 Providing and Laying flooring using pre polished 19 mm thick water
cut/gang saw Granite slab over existing cement concrete bed in CM 1:4
average 20mm thick pointed with white cement/colour pigment etc.,
complete. for grey granite (PWD SR2009-10/P.No. 93/14.47.1) Sqm 1910.00

14.47.2 Providing and Laying flooring using pre polished 19 mm thick water
cut/gang saw Granite slab over existing cement concrete bed in CM 1:4
average 20mm thick pointed with white cement/colour pigment etc., Sqm 2030.00
complete. for black granite (PWD SR2009-10/P.No. 93/14.47.2)

14.48 Providing and Laying flooring for corridors/lobbies using combination of pre
polished 19mm thick water cut/gang saw Grey Granit, black granite, and
strips of 50mm wide pre flamed grey granite using pre polished grey
granite 19mm thick 76% pre polished black granite 19mm thick @ 2% and
preflamed 19mm thick grey granite @ 22% over existing cement concrete Sqm 2825.00
bed in CM 1:4 average 20mm thick pointed with white cement/colour
pigment etc., complete (PWD SR2009-10/P.No. 93-94/14.48)

14.49 Providing and fixing of wall cladding using 20mm thick gang saw water cut
Shiva gold granite, grey granite in CM 1:3 proportion cut to required shape,
pattern with paper joints, finished with cement mortal using white cement
and colour pigments to match the colour of slab making through jointing Sqm 3145.00
with sealant, making holes 25mm x 12mm grooves in joints including
curing etc., complete (PWD SR2009-10/P.No. 94/14.49)
14.50 Providing and fixing skirting of 300 mm high using prepolished water
cut/gang saw of 19mm thick grey granite 0.5mm wide chamfered width
and depth and fixing in CM 1:4 of 20mm thick after chipping the walls etc. m 600.00
complete. (PWD SR2009-10/P.No. 94/14.50)

14.51 Providing and laying Hassan Green granite flooring for staircase, treads
and rises using pre polished 20 mm thick water cut green Granite slab laid
over existing cement concrete bed in CM 1:3, average 20mm thick includig
full rounding fornosing, cutting 3 line grooves not more than 2 mm wide for Sqm 2860.00
antiskidding, curing etc., complete (PWD SR2009-10/P.No. 94/14.51)

FINISHING WORK / PLASTERING


15.1 KSRB 15.1.1 : Providing flush pointing to square rubble, course or
uncoursed stone masonry with cement mortar 1:3, 20mm deep, after
raking joints to depth of 20mm nicely lining, including cost of materials, Sqm 53.00
labour, curing, complete as per specifications. (PWD SR2009-10/P.No.
96/15.1)

15.2 KSRB 15.1.2 : Providing flush pointing to square rubble, course or


uncoursed stone masonry with cement mortar 1:4, 20mm deep, after
raking joints to depth of 20mm nicely lining, including cost of materials, Sqm 51.00
labour, curing, complete as per specifications. (PWD SR2009-10/P.No.
96/15.2)

15.3 KSRB 15.1.3 : Providing ruled pointing to coursed stone masonry with
cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely
lining, including cost of materials, labour, curing, complete as per Sqm 53.00
specifications. (PWD SR2009-10/P.No. 96/15.3)

15.4 KSRB 15.1.4 : Providing ruled pointing to coursed stone masonry with
cement mortar 1:4, 20mm deep, after raking joints to depth of 20mm nicely
lining, including cost of materials, labour, curing, complete as per Sqm 51.00
specifications. (PWD SR2009-10/P.No. 96/15.4)

15.5 KSRB 15.1.5 : Providing raised and cut pointing to coursed stone
masonry with cement mortar 1:3, 20mm, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing, complete as Sqm 78.00
per specifications. (PWD SR2009-10/P.No. 96/15.5)

15.6 KSRB 15.1.6 : Providing raised and cut pointing to coursed stone
masonry with cement mortar 1:4, 20mm, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing, complete as Sqm 75.00
per specifications. (PWD SR2009-10/P.No. 96/15.6)

15.7 KSRB 15.2.1 : Providing flush pointing to stone slab pavements, with
cement mortar 1:3, after ranking joints, nicely lining, including cost of
materials, labour, curing, complete as per specifications. (PWD SR2009- Sqm 18.00
10/P.No. 96/15.7)

15.8 KSRB 15.2.2 : Providing ruled pointing to stone slab pavements with
cement mortar 1:3, 20mm deep, after raking joints, including cost of
materials, labour, curing, complete as per specifications. (PWD SR2009- Sqm 19.00
10/P.No. 96/15.8)
15.9 KSRB 15.3.1 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:3 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding,
including cost of materials, labour, curing, complete as per specifications. Sqm 101.00
(PWD SR2009-10/P.No. 96/15.9)

15.10 KSRB 15.3.2 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:4 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding,
including cost of materials, labour, curing, complete as per specifications. Sqm 90.00
(PWD SR2009-10/P.No. 96/15.10)

15.11 KSRB 15.3.3 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:6 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding,
including cost of materials, labour, curing, complete as per specifications. Sqm 80.00
(PWD SR2009-10/P.No. 96/15.11)

15.12 KSRB 15.3.4 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:3 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding,
including cost of materials, labour, curing, complete as per specifications. Sqm 115.00
(PWD SR2009-10/P.No. 96/15.12)

15.13 KSRB 15.3.5 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:4 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding,
including cost of materials, labour, curing, complete as per specifications. Sqm 102.00
(PWD SR2009-10/P.No. 96/15.13)

15.14 KSRB 15.3.6 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:6 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 89.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 96/15.14)

15.15 KSRB 15.3.7 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:3 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 135.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 96-97/15.15)

15.16 KSRB 15.3.8 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:4 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 120.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 97/15.16)

15.17 KSRB 15.3.9 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:6 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 105.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 97/15.17)
15.18 KSRB 15.3.10 : Providing 20mm thick cement plaster in single coat with
cement mortar 1:3 to stone masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 145.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 97/15.18)

15.19 KSRB 15.3.11 : Providing 20 mm thick cement plaster in single coat with
cement mortar 1:4 to stone masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 128.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 97/15.19)

15.20 KSRB 15.3.12 : Providing 20 mm thick cement plaster in single coat with
cement mortar 1:6 to stone masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 110.00
including cost of materials, labour, curing, complete as per specifications.
(PWD SR2009-10/P.No. 97/15.20)

15.21 KSRB 15.3.13 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:3 to ceiling including rounding off corners wherever
required smooth rendering, : Providing and removing scaffolding, including Sqm 108.00
cost of materials, labour, curing, complete as per specifications. (PWD
SR2009-10/P.No. 97/15.21)

15.22 KSRB 15.3.14 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:4 to ceiling including rounding off corners wherever
required smooth rendering, : Providing and removing scaffolding, including Sqm 97.00
cost of materials, labour, curing, complete as per specifications. (PWD
SR2009-10/P.No. 97/15.22)

15.23 KSRB 15.4.1 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials Sqm 6.80
complete as per specification (PWD SR2009-10/P.No. 97/15.23)

15.24 KSRB 15.4.2 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 12mm thick cost of materials Sqm 5.00
complete as per specification (PWD SR2009-10/P.No. 97/15.24)

15.25 KSRB 15.4.3 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 15mm thick cost of materials Sqm 6.45
complete as per specification (PWD SR2009-10/P.No. 97/15.25)

15.26 KSRB 15.4.4 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 18mm thick cost of materials
Sqm 7.70
complete as per specification (PWD SR2009-10/P.No. 97/15.26)

15.27 KSRB 15.4.5 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials Sqm 8.50
complete as per specification (PWD SR2009-10/P.No. 97/15.27)
15.28 KSRB 15.4.6 : Extra for providing and mixing waterproofing compound in
cement plaster for brick masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:3, Sqm 11.40
20mm thick cost of materials complete as per specification (PWD
SR2009-10/P.No. 97/15.28)

15.29 KSRB 15.4.7 : Extra for providing and mixing water proofing compound in
cement plaster for brick masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:4, Sqm 8.50
20mm thick cost of materials complete as per specification (PWD
SR2009-10/P.No. 97/15.29)

15.30 KSRB 15.5.1 : Providing rough cement plastering 15mm thick in single
coat with cement mortar 1:4, to brick masonry for base of dadooing works
with sand of approved quality, providing and removing scaffolding, Sqm 97.00
including cost of materials, labour, curing, complete as per specification.
(PWD SR2009-10/P.No. 97-98/15.30)

15.31 KSRB 15.5.2 : Providing rough cement plastering 15mm thick in single
coat with cement mortar 1:6, to brick masonry for base of dadooing works
with sand of approved quality, providing and removing scaffolding, Sqm 84.00
including cost of materials, labour, curing, complete as per specification.
(PWD SR2009-10/P.No. 98/15.31)

15.32 KSRB 15-6 : Providing floating coat of cement to plastering and finishing
smooth, including cost of materials, labour, curing, complete as per Sqm 12.00
specification. (PWD SR2009-10/P.No. 98/15.32)

15.33 KSRB 15.7 : Providing lime rendering for plastering to wall and ceiling,
including cost of materials, labour, curing complete as per specifications. Sqm 14.00
(PWD SR2009-10/P.No. 98/15.33)

15.34 KSRB 15.8.1 : Providing and fixing plaster mesh 100 mm wide
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along route of walls
chipped for services, junction between RCC and brick walls including cost m 30.00
of materials, labour for fixing complete as per specifications. (length of
mesh only be measured for payment). (PWD SR2009-10/P.No. 98/15.34)

15.35 KSRB 15.8.2 : Providing and fixing plaster mesh 150 mm wide
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along route of walls
chipped for services, junction between RCC and brick walls including cost m 33.00
of materials, labour for fixing complete as per specifications. (length of
mesh only be measured for payment). (PWD SR2009-10/P.No. 98/15.35)

15.36 KSRB 15.8.3 : Providing and fixing plaster mesh 200 mm wide
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along route of walls
chipped for services, junction between RCC and brick walls including cost
m 42.00
of materials, labour for fixing complete as per specifications. (length of
mesh only be measured for payment). (PWD SR2009-10/P.No. 98/15.36)
15.37 KSRB 15.9 : Providing and fixing corner beads 45x 45mm size
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along exposed
corners of walls, coloumns, lintels including cost of materials, labour for m 16.50
fixing complete (length of mesh only be measured for payment). (PWD
SR2009-10/P.No. 98/15.37)

15.38 KSRB 15.10.1 : Providing white washing to new wall surface in two coats
with lime of approved quality, to given an even shade including csot of
materials, labour, complete as per specification (PWD SR2009-10/P.No. Sqm 4.50
98/15.38)

15.39 KSRB 15.10.2 : Providing white washing for every one additional coat with
lime of approved quality, to give an even shade including cost of materials,
labour, complete as per specifications. (PWD SR2009-10/P.No.98/15.39) Sqm 2.00

15.40 KSRB 15.10.3 : Providing white washing to ceiling and / or sloping roof
surface in two coats with lime of approved quality, to give an even shade
including cost of materials, labour, complete as per specifications. (PWD Sqm 4.50
SR2009-10/P.No. 98/15.40)

15.41 KSRB 15.10.4 : Providing white washing to ceiling and / or sloping roof
surface with additional one coat with lime of approved quality, to give an
even shade including cost of materials, labour, complete as per Sqm 2.40
specifications. (PWD SR2009-10/P.No. 98/15.41)

15.42 KSRB 15.11.1 : Providing cement washing to rough wall surface in one
coat with portland cement slurry to give an even shade after throughly
brooming the surface to remove all dirt, dust, mortar drops and other Sqm 4.00
foreign matter including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 98/15.42)

15.43 KSRB 15.11.2 : Providing cement washing on iron surface in one coat
with portland cement slurry mixed with boiled linseed oil to give an even
surface after throughly cleaning the surface to remove all dirt, dust, mortar Sqm 38.00
drops and other foreign matter including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 99/15.43)

15.44 KSRB 15.12.1 : Providing Gopi colour washing to new wall surface in two
coats with lime and gopi colour of approved quality, to give an even shade
after throughly brooming the surface to remove all dirt, mortar drops and Sqm 7.00
other foreign matter including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 99/15.44)

15.45 KSRB 15.12.2 : Providing Gopi colour washing to new wall surface in one
coat with lime and gopi colour of approved quality, to give an even shade
after throughly brooming the surface to remove all dirt, dust, mortar drops Sqm 4.00
and other foreign matter including cost of materials, labour, complete as
per specifications. (PWD SR2009-10/P.No. 99/15.45)

15.46 KSRB 15.13 : Applying of distemper KSRB 15-13.1 : Providing and


applying one coat distemper primer of approved brand on wall surface
after throughly brooming the surface to remove all dirt, dust, mortar drops
and other foreign matter including preparing the surface, even and sand
paper smooth, cost of materials labour, complete as per specifications.
(PWD SR2009-10/P.No. 99/15.46)
15.46.1 KSRB 15.13 : Applying of distemper KSRB 15-13.1 : Providing and
applying one coat distemper primer of approved brand on wall surface
after throughly brooming the surface to remove all dirt, dust, mortar drops
and other foreign matter including preparing the surface, even and sand Sqm 15.40
paper smooth, cost of materials labour, complete as per specifications.
Wall surface (PWD SR2009-10/P.No.99/15.46.1)

15.46.2 KSRB 15.13.2 : Extra over item 15-13.1 for apprying one coat of
distemper primer over ceiling and / or sloping roof as per specifications. Sqm 1.00
(PWD SR2009-10/P.No. 99/15.46.2)

15.47 KSRB 15.13.3 : Providing and applying two coats dry distemper of
approved brand, and shade on wall surface including priming coat and
whitening after throughly brooming the surface to remove all dirt, dust,
mortar drops and other foreign matter including preparing the surface even
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No.99/15.47)

15.47.1 KSRB 15.13.3 : Providing and applying two coats dry distemper of
approved brand, and shade on wall surface including priming coat and
whitening after throughly brooming the surface to remove all dirt, dust,
mortar drops and other foreign matter including preparing the surface even Sqm 31.00
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 99/15.47.1)

15.47.2 KSRB 15.13.4 : Extra over item 15-13.3 for appying distemper primer over
ceiling and / or sloping roof as per specification. (PWD SR2009-10/P.No. Sqm 2.10
99/15.47.2)

15.48 KSRB 15.13.5 : Providing and applying one coat on old surface dry
distemper of approved brand, and shade on wall surface after throughly
brooming the surface clean of all gease, dirt, loose pieces of scales
including preparing the surface even and sand paper smooth, cost of
material, labour, complete as per specification (PWD SR2009-10/P.No.
99/15.48)

15.48.1 KSRB 15.13.5 : Providing and applying one coat on old surface dry
distemper of approved brand, and shade on wall surface after throughly
brooming the surface clean of all gease, dirt, loose pieces of scales
including preparing the surface even and sand paper smooth, cost of Sqm 9.50
material, labour, complete as per specification wall surface (PWD
SR2009-10/P.No.99/15.48.1)

15.48.2 KSRB 15.13.6 : Extra over item 15-13.5 for applying distemper over
ceiling and / or sloping roof as per specifications. (PWD SR2009-10/P.No. Sqm 0.50
99/15.48.2)

15.48.3 KSRB 15.13.7 : Extra for providing and applying every subsequent cost of
dry distemper of approved brand, for item no.15-13.3 & 15-13.5 of
approved shade on wall surface cost of materials, labour, complete as per Sqm 6.50
specifications. (PWD SR2009-10/P.No. 100/15.48.3)

15.49 KSRB 15.14.1 : Providing and applying two coats with oil bound washable
distemper of approved brand and shade on wall surface including priming
coat with distemper primer after throughly brooming the surface free from
mortar drops and other foreign matter including preparing the surface even
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 100/15.49)
15.49.1 KSRB 15.14.1 : Providing and applying two coats with oil bound washable
distemper of approved brand and shade on wall surface including priming
coat with distemper primer after throughly brooming the surface free from
mortar drops and other foreign matter including preparing the surface even Sqm 45.00
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 100/15.49.1)

15.49.2 KSRB 15.14.2 : Extra over item 15-14.1 for applying oil bound washable
distemper on ceiling and / or sloping roof as per specifications. (PWD Sqm 2.50
SR2009-10/P.No. 100/15.49.2)

15.50 KSRB 15.14.3 : Providing and applying one coat with oil bound washable
distemper of approved brand and shade on wall surface to give an even
shade after throughly brooming the surface free from all grease, dirt, loose
peases of scales, including preparing the surface even and sand paper
smooth, cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 100/15.50)

15.50.1 KSRB 15.14.3 : Providing and applying one coat with oil bound washable
distemper of approved brand and shade on wall surface to give an even
shade after throughly brooming the surface free from all grease, dirt, loose
peases of scales, including preparing the surface even and sand paper Sqm 18.50
smooth, cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 100/15.50.1)

15.50.2 KSRB 15.14.4 : Extra over item 15-14.3 for applying one coat with oil
bound washable distemper on ceiling and / or sloping roof as per Sqm 1.00
specifications. (PWD SR2009-10/P.No. 100/15.50.2)

15.51 KSRB 15.15.1: Providing and applying painting in two coats with plastic
emulsion paint of approved brand on wall surface to give an even
approved shade after throughly brushing the surface, free from mortar
drops and other foreign matter including preparing the surface even and
sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 112/15.51)

15.51.1 KSRB 15.15.1: Providing and applying painting in two coats with plastic
emulsion paint of approved brand on wall surface to give an even
approved shade after throughly brushing the surface, free from mortar
drops and other foreign matter including preparing the surface even and Sqm 45.00
sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 100/15.51)

15.51.2 KSRB 15.15.1: Providing and applying painting in two coats with Primer
with plastic emulsion paint of approved brand on wall surface to give an
even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface even Sqm 60.00
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 100/15.51.2)

15.51.3 KSRB 15.15.2 : Extra over item 15-15.1 for applying two coats with plastic
emulsion paint of approved brand and shade on ceiling and / or sloping Sqm 1.70
roof as per specifications. (PWD SR2009-10/P.No. 100/15.51.3)
15.52 KSRB 15.15.3 : Providing and applying painting in one coat with plastic
emulsion paint of approved brand and manufacture on wall surface to give
an even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface even
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 100/15.52)

15.52.1 KSRB 15.15.3 : Providing and applying painting in one coat with plastic
emulsion paint of approved brand and manufacture on wall surface to give
an even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface even
Sqm 29.00
and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 101/15.52.1)

15.52.2 KSRB 15.15.4 : Extra over item 15-15.3 for painting with one coat plastic
emulsion paint of approved brand and shade on ceiling and / or sloping
roof as per specifications. (PWD SR2009-10/P.No. 101/15.52.2) Sqm 1.30

15.52.3 KSRB 15.15.5 : Extra for providing and applying every subsequent coat of
painting with plastic emulsion paint of approved brand and shade for item
no. 15-15.1 and 15-15.3 cost of materials, labour, complete as per Sqm 19.00
specifications. (PWD SR2009-10/P.No. 101/15.52.3)

15.53 KSRB 15-16.1 : Providing and finishing external walls in two coats with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
101/15.53)

15.53.1 KSRB 15-16.1 : Providing and finishing external walls in two coats with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of Sqm 33.00
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
101/15.53.1)

15.53.2 KSRB 15.16 : Water proof cement paint KSRB 15-16.1 : Providing and
finishing external walls in two coats with waterproof cement paint with
primer of approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free Sqm 50.00
from mortar drops and other foreign matter cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No.101/15.53.2)

15.53.3 KSRB 15.16.3 : Extra for providing and applying every subsequent coat of
waterproofing cement paint of approved brand and shade for item no. 15-
16.1 cost of materials, labour, complete as per specifications. (PWD Sqm 12.50
SR2009-10/P.No. 101/15.53.3)
15.54 KSRB 15.16 : Water proof cement paint KSRB 15-16.2 : Providing and
finishing external walls in one coat with waterproof cement paint of
approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free
from mortar drops and other foreign matter cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 101/15.54)

15.54.1 KSRB 15.16 : Water proof cement paint KSRB 15-16.2 : Providing and
finishing external walls in one coat with waterproof cement paint of
approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free
Sqm 19.00
from mortar drops and other foreign matter cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 101/15.54.1)

15.54.2 KSRB 15.16 : Water proof cement paint KSRB 15-16.2 : Providing and
finishing external walls in one coat with waterproof cement paint with
primer of approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free
from mortar drops and other foreign matter cost of materials, labour, Sqm 27.00
complete as per specifications. (PWD SR2009-10/P.No. 101/15.54.2)

15.54.3 KSRB 15.16.3 : Extra for providing and applying every subsequent coat of
waterproofing cement paint of approved brand and shade for item no. 15-
16.1 and 15-16.2 cost of materials, labour, complete as per specifications. Sqm 12.80
(PWD SR2009-10/P.No. 101/15.54.3)

15.55 KSRB 15.17 : Painting of wood surface KSRB 15-17.21 : Applying priming
coat over new wood surface and / or wood based surface with while lead
paint preming including preparing the surface after throughly cleaning oil,
grease, dirt and foreign matter, sand papering and knotting ready mix paint Sqm 25.50
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 101/15.55)

15.56 KSRB 15.17.2 : Applying priming coat over new wood surface and / or
wood based surface after brushing with wood primer pink paint including
preparing the surface after throughly cleaning oil, grease, dirt and foreign
matter, sand papering and knotting ready mix paint including cost of Sqm 17.00
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
101/15.56)

15.57 KSRB 15.17.3 : Applying priming coat over new wood surface and / or
wood based surface after brushing with aluminium paint primer, water
resistant including preparing the surface after throughly cleaning oil,
grease, dirt and foreign matter, sand papering and knotting ready mix paint Sqm 31.50
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 102/15.57)

15.58 KSRB 15.17.4 : Applying priming coat over new wood surface and / or
wood based surface after brushing with ready mix eanamel priming paint
including preparing the surface after throughly cleaning oil, grease, dirt and
foreign matter, sand papering and knotting ready mix paint including cost Sqm 22.50
of materials, labour, complete as per specifications. (PWD SR2009-
10/P.No. 102/15.58)
15.59 KSRB 15.17.5 : Applying priming coat over new wood surface and / or
wood based surface after preparing the surface after throughly cleaning
oil, grease, dirt and foreign matter, sand papering and knotting liquid wood Sqm 25.50
filler, for varnish including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 102/15.59)

15.60 KSRB 15.17.6 : Providing and applying painting two coats (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust
and forign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 102/15.60)

15.60.1 KSRB 15.17.7 : Providing and applying painting two coats (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust Sqm 51.00
and forign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 102/15.60.1)

15.60.2 KSRB 15.17.8 : Extra over item No 15-17.6 for applying every subsequent
coat of enamel paint to give an even shade after cleaning the surface of all
dirt, dust and foreign matter, sand papering including cost of materials, Sqm 29.50
labour, complete as per specification. (PWD SR2009-10/P.No.
102/15.60.2)

15.61 KSRB 15.17.7 : Providing and applying painting one coat (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust
and forign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 102/15.60.1)

15.61.1 KSRB 15.17.7 : Providing and applying painting one coat (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust
and forign matter, sand papering including cost of materials, labour, Sqm 31.50
complete as per specifications. (PWD SR2009-10/P.No. 102/15.61.1)

15.61.2 KSRB 15.17.8 : Extra over item No 15-17.7 for applying every subsequent
coat of enamel paint to give an even shade after cleaning the surface of all
dirt, dust and foreign matter, sand paperig including cost of materials, Sqm 29.50
labour, complete as per specifications. (PWD SR2009-10/P.No.
102/15.61.2)

15.62 KSRB 15.17.9 : Applying varnish two coats (excluding priming coat) on
new wood surface and / or wood based surface undercoating with flatting
varnish and finishing coat with varnish to give an even shade after
cleaming so as to produce smooth dry, mat surface including cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
102/15.62)

15.62.1 KSRB 15.17.9 : Applying varnish two coats (excluding priming coat) on
new wood surface and / or wood based surface undercoating with flatting
varnish and finishing coat with varnish to give an even shade after
cleaming so as to produce smooth dry, mat surface including cost of Sqm 48.00
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
102/15.62)
15.62.2 KSRB 15.17.11 : Extra over item No 15-17.9 and 15.17.10 for applying
every subsequent coat of varnish to produce a smooth dry and mat
surface after cleaning the surface of all dirt, dust and foreign matter, Sqm 23.00
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 102-103/15.62.2)

15.63 KSRB 15.17.10 : Providing and Applying varnishing one coat (excluding
priming coat) on previously varnished wood / or wood based surface to
give an even surface after cleaning the surface of all dirt, dust and foreign
matter, sand papering so as to produce a smooth dry and mat surface
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 103/15.63)

15.63.1 KSRB 15.17.10 : Providing and Applying varnishing one coat (excluding
priming coat) on previously varnished wood / or wood based surface to
give an even surface after cleaning the surface of all dirt, dust and foreign
matter, sand papering so as to produce a smooth dry and mat surface Sqm 25.00
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 103/15.63)

15.63.2 KSRB 15.17.11 : Extra over item No. 15-17.9 and 15-17.10 for applying
every subsequent coat of varnish to produce a smooth dry and mat
surface after cleaning the surface of all dirt, dust and foreign matter, Sqm 23.00
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 103/15.63.2)

15.64 KSRB 15.17.12 : Providing and Applying polishing with french polish on
new wood surface and / or wood based suface to give an even surface
after cleaning the surface of all dirt, dust and foreign matter, sand papered Sqm 78.00
smooth including cost of materials, labour, complete as per specifications.
(PWD SR2009-10/P.No. 103/15.64)

15.65 KSRB 15.17.13 : Providing and Applying polishing with french polish over
previously polished wood or wood based surface to give an even surface
after cleaning the surface of all dirt, dust and foreign matter, sand papered Sqm 40.00
smooth including cost of materials, labour, complete as per specifications.
(PWD SR2009-10/P.No. 103/15.65)

15.66 KSRB 15.17.14 : Providing and Applying wax polish in two coats on new
wood surface and / or wood based surface with bees wax polish in
proportion of 2:1.5:1:0.5 (2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5
varnish by weight) to give an even surface after cleaning the surface of all Sqm 41.00
dirt, dust and foreign matter, sand papered smooth including cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
103/15.66)

15.67 KSRB 15.17.15 : Providing and Applying wax polish in single coat on new
wood surface and / or wood based surface with bees wax polish in
proportion of 2:1.5:1:0.5 (2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5
varnish by weight) to give an even surface after cleaning the surface of all Sqm 20.00
dirt, dust and foreign matter, sand papered smooth including cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
103/15.67)

15.68 KSRB 15.17.16 : Providing and applying painting two coat (excluding
priming coat) on new wood surface and / or wood based surface with coal
tar paint to give an even shade after cleaning the surface of all dirt, dust Sqm 21.00
and foreign matter, including cost of materials, labour, complete as per
speciications. (PWD SR2009-10/P.No. 103/15.68)
15.69 KSRB 15.17.17 : Providing and applying painting one coat (excluding
priming coat) on new wood surface and / or wood based surface with coal
tar paint to give an even shade after cleaning the surface of all dirt, dust Sqm 13.50
and foreign matter, including cost of materials, labour, complete as per
speciications. (PWD SR2009-10/P.No. 103/15.69)

15.70 KSRB 15.17.18 : Providing and applying painting one coat (excluding
priming coat) on previously painted wood surface and / or wood based
surface with coal tap paint to give an even shade after cleaning the
surface of all dirt. dust and foreign matter, including cost of materials, Sqm 11.50
labour, complete as per specifications. (PWD SR2009-10/P.No. 104/15.70)

15.71 KSRB 15.17.19 : Providing and applying painting one coat (excluding
priming coat) on previously painted wood surface and / or wood based
surface with black japan paint to give an even shade after cleaning the
surface of all dirt. dust and foreign matter, including cost of materials, Sqm 21.50
labour, complete as per specifications. (PWD SR2009-10/P.No. 104/15.71)

15.72 KSRB 15.17.20 : Applying additional one coat (excluding priming coat) on
previously painted wood surface and / or wood based surface with black
japan paint to give an even shade after cleaning the surface of all dirt. dust Sqm 19.50
and foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.72)

15.73 KSRB 15.18.1 : Applying red lead ready mix priming coat over new steel
or other metal surface including preparing the surface after throughly
cleaning oil, grease, dirt and other foreign matter, and scoured with wire Sqm 19.50
brushes, fine steel wool, sand papers including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 104/15.73)

15.74 KSRB 15.18.2 : Providing and applying enamel metal paint two coats
(excluding priming coat) over new steel or other metal surface brushing to
give an even shade after cleaning oil, grease, dirt and other foreign Sqm 50.00
matter, including cost of materials, labour, complete as per specifications.
(PWD SR2009-10/P.No. 104/15.74)

15.75 KSRB 15.18.3 : Providing and applying enamel metal paint one coat
(excluding priming coat) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 31.00
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.75)

15.76 KSRB 15.18.4 : Providing and applying alluminium paint two coats
(excluding priming coat) over new steel or other metal surface brushing to
give an even shade after cleaning oil, grease, dirt and other foreign matter, Sqm 36.00
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 104/15.76)

15.77 KSRB 15.18.5 : Providing and applying alluminium paint one coat
(excluding priming coat) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 22.00
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.77)

15.78 KSRB 15.18.6 : Providing and applying black japan paint one coat
(excluding priming coat) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 21.50
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.78)
15.79 KSRB 15.18.7 : Extra for applying every subsequent black japan paint on
previously painted steel or other metal surface brushing to give an even
shade after cleaning oil, grease, dirt and other foreign matter, including Sqm 19.50
cost of materials, labour, complete as per specifications. (PWD SR2009-
10/P.No. 104/15.79)

15.80 KSRB 15.19.1 : Providing and applying ready mix priming coat over
concrete / masonry / asbestos cement sheet / plastered surfaces including
preparing the surface after throughly cleaning of oil, grease, dirt and other Sqm 18.50
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.80)

15.81 KSRB 15.19.2 : Providing and applying spray painting in two coats
(exluding priming coat) over concrete / masonry / asbestos cement sheet /
plastered surfaces wtih flat wall paint of approved brand to give even
shade after cleaning the surface of all dirt, dust and other foreign matter, Sqm 46.50
and sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.81)

15.82 KSRB 15.19.3 : Providing and applying spray painting in one coat
(exluding priming coat) over concrete / masonry / asbestos cement sheet /
plastered surfaces wtih flat wall paint of approved brand to give even
shade after cleaning the surface of all dirt, dust and other foreign matter, Sqm 29.00
and sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.82)

15.83 KSRB 15.20.1 : Providing and applying floor painting with ready mix paint
in two coats (exluding priming coat) on new concrete / asbestos cement
sheet / plastered surfaces brushing to give an even shade after preparing
the surface after throughly cleaning oil, dirt, dust other foreign matter and Sqm 33.50
sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.83)

15.84 KSRB 15.20.2 : Providing and applying floor painting with ready mix paint
in one coat (excluding priming coat) on new concrete / asbestos cement
sheet / plastered surfaces brushing to give an even shade after preparing
the surface after throughly cleaning oil, dirt, dust other foreign matter and Sqm 21.50
sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.84)

15.85 KSRB 15.21.1 : Providing and applying wax polish on new concrete floor
and vertical plastered surface using approved brand to give an even shade
after preparing the surface after throughly cleaning oil, dirt, dust othe Sqm 16.00
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 104/15.85)

15.86 KSRB 15.21.2 : Providing and applying wax polish on previously polished
concrete floor and vertical plastered surface using wax polish of approved
brand to give an even shade after preparing the surface after throughly
cleaning oil, dirt, dust and other foreign matter, including cost of materials, Sqm 15.00
labour, complete as per specifications. (PWD SR2009-10/P.No.
104/15.86)
15.87 KSRB 15.22.1 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size dark shade pigment with ordinary cement (in
top layer only) laid in cement marble powder 3:1 (3 cement : 1 marble
powder by weight) in proportion of 4:7 (4 cement marble powder mix : 7 Sqm 665.00
marble chips by volume) overall thickness 24mm (18mm thick under layer,
6mm thick top layer) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
104/15.87)

15.88 KSRB 15.22.2 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, light shade pigment with white cement (in
top layer only) laid in cement marble powder 3:1 (3 cement : 1 marble
powder by weight) in proportion of 4:7 (4 cement marble powder mix : 7 Sqm 770.00
marble chips by volume) overall thickness 24mm (18mm thick under layer,
6mm thick top layer) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
105/15.88)

15.89 KSRB 15.22.3 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, medium shade pigment with approximately
50% white cement and 50% ordinary cement (in top layer only) laid in
cement marble powder 3:1 (3 cement : 1 marble powder by weight) in
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by Sqm 725.00
volume) overall thickness 24mm (18mm thick under layer, 6mm thick top
layer) in cement mortar of mix 1:3 including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 106/15.89)

15.90 KSRB 15.22.4 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, white cement without any pigment (in top
layer only) laid in cement marble powder 3:1 (3 cement : 1 marble powder
by weight) in proportion of 4:7 (4 cement marble powder mix : 7 marble Sqm 680.00
chips by volume) overall thickness 24mm (18mm thick under layer, 6mm
thick top layer) in cement mortar of mix 1:3 including cost of materials,
labour, complete as per specifications. (PWD SR2009-10/P.No. 106/15.90)

15.91 KSRB 15.22.5 : Extra labour for work in dado exceeding 30 cms in height
including cost of labour, complete as per specifications. (PWD SR2009- Sqm 10.00
10/P.No. 106/15.91)

15.92 KSRB 15.23.1 : Providing pre-cast mosaic tiles 20mm thick with marble
chips of white, black, chocolate, grey, yellow or baroda green from
smallest to 6mm nominal size with ordinary cement (in top layer only) for
skirting and rises of steps (not exceeding 30cms height) on 10 cms thick m 165.00
cement mortar 1:3 jointed with neat cement slurry, rubbed and polished to
granolitic finish, including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 106/15.92)
15.93 KSRB 15.23.2 : Providing pre-cast mosaic tiles using light shade pigmant
with white cement 20mm thick with marble chips of white, black, chocolate,
grey, yellow or baroda green from smallest to 6mm nominal sizewith
ordinary cement (in top layer only) for skirting and rises of steps (not
exceeding 30cms height) on 10 cms thick cement mortar 1:3 jointed with m 255.00
neat cement slurry, rubbed and polished to granolitic finish, including cost
of materials, labour, complete as per specifications. (PWD SR2009-
10/P.No. 106/15.93)

15.94 KSRB 15.23.3 : Providing pre-cast mosaic tiles using medium shade
pigmant using approximately 50% white cement and 50% ordinary cement
20mm thick with marble chips of white, black, chocolate, grey, yellow or
baroda green from smallest to 6mm nominal sizewith ordinary cement (in
top layer only) for skirting and rises of steps (not exceeding 30cms height)
m 235.00
on 10 cms thick cement mortar 1:3 jointed with neat cement slurry, rubbed
and polished to granolitic finish, including cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 107/15.94)

15.95 KSRB 15.23.4 : Providing pre-cast mosaic tiles of white shade with white
cement whithout any pigmant 20mm thick with marble chips of white,
black, chocolate, grey, yellow or baroda green from smallest to 6mm
nominal size with ordinary cement (in top layer only) for skirting and rises
of steps (not exceeding 30cms height) on 10 cms thick cement mortar 1:3 m 200.00
jointed with neat cement slurry, rubbed and polished to granolitic finish,
including cost of materials, labour, complete as per specifications. (PWD
SR2009-10/P.No. 107/15.95)

15.96 Providing melamine polishing of approved shade including removing and


refixing of doors shutters scraping with blade and rubbing with zero size
sand paper and applying sealer coat by way of spraying with necessary
compressor and applying patty after rubbing with steel wool including two Sqm 530.00
coats of approved shade of melamine polish etc., complete (PWD
SR2009-10/P.No. 107/15.96)

15.97 Providing melamine polishing of approved shade including removing and


refixing of doors shutters, glass, beading and existing polishing, scraping
with blade and rubbing with zero size sand paper and applying sealer coat
by way of spraying with necessary compressor and applying patty after Sqm 630.00
rubbing with steel wool including two coats of approved shade of melamine
polish etc., complete. (PWD SR2009-10/P.No. 107/15.97)

15.98 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of
cement. (PWD SR2009-10/P.No. 107/15.98)

15.98.1 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 4.25
cement. for CM 1:4, 20mm thick (PWD SR2009-10/P.No. 107/15.98.1)

15.98.2 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 3.10
cement. for CM 1:4, 12mm thick (PWD SR2009-10/P.No. 107/15.98.2)
15.98.3 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 2.85
cement. for CM 1:6, 20mm thick (PWD SR2009-10/P.No. 107/15.98.3)

15.98.4 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 2.15
cement. for CM 1:6, 12mm thick (PWD SR2009-10/P.No. 107/15.98.4)

15.99 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers for use as micro secondary reinforcement in guitie and
shotcrete civil works with application dosage of 125-175 grams per bag of Sqm 10.00
cement i.e. 0.25% - 0.30% by weight of cement (PWD SR2009-10/P.No.
107/15.99)

15.100 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster.
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. (PWD SR2009-
10/P.No. 107-108/15.100)

15.100.1 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 23.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:3, 20mm thick
(PWD SR2009-10/P.No. 108/15.100.1)

15.100.2 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 15.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:3, 12mm thick
(PWD SR2009-10/P.No. 108/15.100.2)

15.100.3 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 21.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:4, 20mm thick
(PWD SR2009-10/P.No. 108/15.100.3)
15.100.4 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 13.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:4, 12mm thick
(PWD SR2009-10/P.No. 108/15.100.4)

15.100.5 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 18.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:6, 20mm thick
(PWD SR2009-10/P.No. 108/15.100.5)

15.100.6 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster.
Sqm 13.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:6, 12mm thick
(PWD SR2009-10/P.No. 108/15.100.6)

15.101 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 (PWD SR2009-
10/P.No. 108/15.101)

15.101.1 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster Sqm 38.00
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:3,
20mm thick (PWD SR2009-10/P.No. 108/15.101.1)

15.101.2 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster Sqm 25.00
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:3,
12mm thick (PWD SR2009-10/P.No. 108/15.101.2)
15.101.3 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster Sqm 34.00
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:4,
20mm thick (PWD SR2009-10/P.No. 108/15.101.3)

15.101.4 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster Sqm 21.00
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:4,
12mm thick (PWD SR2009-10/P.No. 108/15.101.4)

15.101.5 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster Sqm 32.00
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:6,
20mm thick (PWD SR2009-10/P.No. 108/15.101.5)

15.101.6 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster Sqm 28.00
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:6,
12mm thick (PWD SR2009-10/P.No. 108/15.101.6)

15.102 Providing and mixing Harbourite 12mm fibrillated 100% virgin


polypropylene fibers which should be free from reprocessed olefin
materials and specifically manufactured for use as cementitious micro
reinforcement application rate of 175 gms to 250 gms per bag of cement or
1.8 kg per cum in the guinite/shotcret and designed to an optimum Sqm 67.00
gradation for use as concrete secondary reinforcement. Fiber mesh
Harbourite fibers 12mm fibers should be confirming to ASTM C-1116
(PWD SR2009-10/P.No. 108/15.102)

REPAIRS TO BUILDINGS

16.1 KSRB 24.1 : Removing white wash or colour wash by steel brushing and /
or scraping, sand papering and preparing wall surface smooth including
repairs to scraches, cost of labour complete as per specifications. (PWD
SR2009-10/P.No. 111/16.1)
16.1.1 KSRB 24.1 : Removing white wash or colour wash by steel brushing and /
or scraping, sand papering and preparing wall surface smooth including
repairs to scraches, cost of labour complete as per specifications. (PWD Sqm 3.00
SR2009-10/P.No. 111/16.1.1)

16.1.2 KSRB 24.2 :Removing white wash or colour wash by steel brushing and /
or scraping, sand papering the ceiling and / or sloping roof surface smooth
including repairs to scraches, cost of labour complete as per Sqm 3.30
specifications. (PWD SR2009-10/P.No. 111/16.1.2)

16.1.3 KSRB 24.3 : Extra for washing the wall surface spoiled by smoke, soot,
with clear water before sand papering the A80 surface smooth including
necessary repairs to scraches, cost of labour, complete as per Sqm 1.30
specifications. (PWD SR2009-10/P.No. 111/16.1.3)

16.1.4 KSRB 24.4 : Extra for item No. 24-3 washing the ceiling and / or sloping
wall surface spoiled by smoke, soot, with clear water before sand papering
the A80 surface smooth including necessary repairs to scraches, cost of Sqm 1.40
labour, complete as per specifications. (PWD SR2009-10/P.No.
111/16.1.4)

16.2 KSRB 24.5 : Cleaning and washing of decorated wall surface with soap
and water including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 111/16.2)

16.2.1 KSRB 24.5 : Cleaning and washing of decorated wall surface with soap
and water including cost of materials, labour, complete as per Sqm 1.40
specifications. (PWD SR2009-10/P.No. 111/16.2.1)

16.2.2 KSRB 24.6 : Extra for KSRB 24-5 cleaning and washing the old ceiling
and / or sloping roof with soap, soda and water including cost of materials,
labour, complete as per specifications. (PWD SR2009-10/P.No. Sqm 1.50
111/16.2.2)

16.3 KSRB 24.7 : Cleaning and washing the old plastered wall surface with
soap, soda, water including cost of materials, labour, complete as per
specifications. (PWD SR2009-10/P.No. 111/16.3)

16.3.1 KSRB 24.7 : Cleaning and washing the old plastered wall surface with
soap, soda, water including cost of materials, labour, complete as per Sqm 1.40
specifications. (PWD SR2009-10/P.No. 111/16.3.1)

16.3.2 KSRB 24.8 : Cleaning and washing the old plastered ceiling and / or
sloping roof surface with soap, soda, water including cost of materials,
labour, complete as per specifications (PWD SR2009-10/P.No. 111/16.3.2) Sqm 1.50

16.4 KSRB 24.9 : Cleaning and washing of stone masonry wall surface with
nitric acid including cost of materials, labour, complete as per Sqm 2.40
specifications. (PWD SR2009-10/P.No. 111/16.4)

16.5 KSRB 24.10 : Removing the old paint or polish from wood and / or wood
based surface with paint remover of approved brand / manufactur and
making surface even including cost of materials, labour, complete as per Sqm 32.00
specifications. (PWD SR2009-10/P.No. 111/16.5)

16.6 KSRB 24.11 : Removing the old paint or polish from wood and / or wood
based surface with caustic soda solution and making surface even
including cost of materials, labour, complete as per specifications. (PWD Sqm 18.50
SR2009-10/P.No. 112/16.6)
16.7 KSRB 24.12 : Removing the old paint from wood and / or wood based
surface with blow lamp and making surface even including cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No. Sqm 35.00
112/16.7)

16.8 KSRB 24.13 : Removing the old paint from steel and / or other metal
surface with hand scraping and making surface even including cost of
labour, complete as per specifications. (PWD SR2009-10/P.No. 112/16.8) Sqm 28.00

16.9 KSRB 24.14 : Removing the old paint from steel and / or other metal
surface with flame cleaning and making surface even including cost of
labour, complete as per specifications. (PWD SR2009-10/P.No. 112/16.9) Sqm 35.00

16.10 KSRB 24.15 : Removing the old paint from steel and / or other metal
surface with paint remover of approved brand / manufacturer cleaning and
making surface even including cost of materials, labour, complete as per Sqm 32.00
specifications. (PWD SR2009-10/P.No. 112/16.10)

16.11 KSRB 24.16 : Fixing small pieces (not exceeding 0.015 cum) for making
good wherever hinges etc., have been removed from frames or joinery
etc., with teak wood excluding cost of materials but including cost of Piece 8.00
labour, complete as per specifications. (PWD SR2009-10/P.No. 112/16.11)

16.12 KSRB 24.17 : Providing and fixing small pieces (not exceeding 0.015
cum) for making good wherever hinges etc., have been removed from
frames or joinery etc., with honne wood including cost of materials, labour, Piece 115.00
complete as per specifications. (PWD SR2009-10/P.No. 112/16.12)

16.13 KSRB 24.18 : Providing and fixing small pieces (not exceeding 0.015
cum) for making good wherever hinges etc., have been removed from
frames or joinery etc., with matti / nandi wood including cost of materials, Piece 91.00
labour, complete as per specifications. (PWD SR2009-10/P.No. 112/16.13)

16.14 KSRB 24.19 : Providing and fixing small pieces (not exceeding 0.015
cum) for making good wherever hinges etc., have been removed from
frames or joinery etc., with sal wood including cost of materials, labour, Piece 74.00
complete as per specifications. (PWD SR2009-10/P.No. 112/16.14)

16.15 KSRB 24.20 : Renewing bars, styles and rails, straight for joinery upto 50
mm thick including mitres, haunching, mortices etc., and removing the old
defective pieces and replacing with Teak wood including cost of materials, Piece 680.00
labour, complete as per specifications. (PWD SR2009-10/P.No. 112/16.15)

16.16 KSRB 24.21 : Renewing bars, styles and rails, straight for joinery upto 50
mm thick including mitres, haunching, mortices etc., and removing the old
defective pieces and replacing with Honne wood including cost of Piece 320.00
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
112/16.16)
16.17 KSRB 24.22 : Renewing bars, styles and rails, straight for joinery upto 50
mm thick including mitres, haunching, mortices etc., and removing the old
defective pieces and replacing with Matti/ Nandi wood including cost of Piece 255.00
materials, labour, complete as per specifications. (PWD SR2009-10/P.No.
112/16.17)

16.18 KSRB 24.23 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm per leaf, removing or
dismantling excluding cost of wood but including cost of labour, complete Leaf 190.00
as per specifications. (PWD SR2009-10/P.No. 112/16.18)

16.19 KSRB 24.24 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm but not exceeding
two sqm per leaf, removing or dismantling excluding cost of wood but Leaf 250.00
including cost of labour, complete as per specifications. (PWD SR2009-
10/P.No. 113/16.19)

16.20 KSRB 24.25 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding two sqm removing or Leaf 355.00
dismantling excluding cost of wood but including cost of labour, complete
as per specifications. (PWD SR2009-10/P.No. 113/16.20)

16.21 KSRB 24.26 : Making repairs to joinery at angles with 300mm x 25mm x
3mm length of MS flat forged to shape and let into wood work, counter
sunk, drilled and screwed including cost of materials, labour, complete as Each 53.00
per specifications. (PWD SR2009-10/P.No. 113/16.21)

16.22 KSRB 24.27 : Renewing Honne wood batterns in roof including making
good the holes in walls, removal of rubbish to the dumping round with a
lead upto 50 m including cost of materials, labour, complete as per Cum 8050.00
specifications. (PWD SR2009-10/P.No. 113/16.22)

16.23 KSRB 24.28 : Renewing Matti / Nandi wood batterns in roof including
making good the holes in walls, removal of rubbish to the dumping round
with a lead upto 50 m including cost of materials, labour, complete as per Cum 6560.00
specifications. (PWD SR2009-10/P.No. 113/16.23)

16.24 KSRB 24.29 : Renewing Sal wood battens in roof including making good
the holes in walls, removal of rubbish to the dumping round with a lead
upto 50 m including cost of materials, labour, complete as per Cum 5540.00
specifications. (PWD SR2009-10/P.No. 113/16.24)

16.25 KSRB 24.30 : Removal of old broken glass panes (any thickness of size,
quality or description) from wooden frames, glazed with putty or fixed with
beads including cost of labour, complete as per specifications. (PWD Sqm 41.00
SR2009-10/P.No. 113/16.25)

16.26 KSRB 24.31 : Removal of old broken glass panes (any thickness of size,
quality or description) from metal frames, glazed with putty or fixed with
beads including cost of labour, complete as per specifications. (PWD Sqm 58.00
SR2009-10/P.No. 113/16.26)
16.27 KSRB 24.32 : Removing serviceable glass of any description from old
wood or metal frames (any thickness or size, quality or description)
hacking out old putty etc., including risk and making good breakages in
taking out and handling, stacking within a lead of 50 m including cost of Sqm 59.00
labour, complete as per specifications. (PWD SR2009-10/P.No. 113/16.27)

16.28 KSRB 24.33 : Supplying and fixing new teak wood beads wherever
necessary including cost of materials, labour, complete as per m 20.00
specifications. (PWD SR2009-10/P.No. 113/16.28)

16.29 KSRB 24.34 : Supplying and fixing new Honne wood beads wherever
necessary including cost of materials, labour, complete as per m 13.50
specifications. (PWD SR2009-10/P.No. 113/16.29)

16.30 KSRB 24.34 : Renewal of old putty of glass panes including cost of
materials, labour, complete as per specifications. Specification No KBS m 14.00
24.2.6 (PWD SR2009-10/P.No. 113/16.30)

16.31 KSRB 24.36 : Removing the glazed tiles in patches in area exceeding 10
tiles and not exceeding 5 sqm including removing old tiles preparing
surface and laying or setting new or old tiles complete including cost of Sqm 310.00
materials, (excluding cost of tiles) labour, complete as per specifications.
(PWD SR2009-10/P.No. 113/16.31)

16.32 KSRB 24.37 : Removing the mosaic tiles in patches in area exceeding
10 tiles and not exceeding 5 sqm including removing old tiles preparing
surface and laying or setting new or old tiles complete including cost of Sqm 249.00
materials, (excluding cost of tiles) labour, complete as per specifications.
(PWD SR2009-10/P.No. 114/16.32)

16.33 KSRB 24.38 : Cutting out cracks of roof terrace to V - section cleaning
out, wetting, grouting with cement and sand slurry 1:3 (1 ceemnt, 3 sand)
including cost of materials, labour, complete as per specifications.(PWD m 23.00
SR2009-10/P.No. 114/16.33)

16.34 KSRB 24.39 : Cutting out cracks of roof terrace to V - section cleaning
out, and filling solidly with a hot mixure of bitumen and clean dry sand 1:1
by weight including cost of materials, labour, complete as per Sqm 23.00
specifications (PWD SR2009-10/P.No. 114/16.34)

16.35 KSRB 24.40 : Dubbing out on old irregular walls average 10 mm thick and
making good the surface with cement mortar 1:3 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS
24.2.1 (PWD SR2009-10/P.No. 114/16.35)

16.35.1 KSRB 24.40 : Dubbing out on old irregular walls average 10 mm thick and
making good the surface with cement mortar 1:3 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS Sqm 104.00
24.2.1 (PWD SR2009-10/P.No. 114/16.35.1)

16.35.2 KSRB 24.43 : Add from item No. 24-40 for every 5mm thick increase after
10mm with respective mortars including curing cost of materials, labour,
complete as per specifications. (PWD SR2009-10/P.No. 114/16.35.2) Sqm 28.00
16.36 KSRB 24.41 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:4 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS
24.2.1 (PWD SR2009-10/P.No. 114/16.36)

16.36.1 KSRB 24.41 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:4 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS Sqm 87.00
24.2.1 (PWD SR2009-10/P.No. 114/16.36.1)

16.36.2 KSRB 24.43 : Add from Item No. 24.40, 24.41, 24.42 for every 5mm thick
increase after 10mm with respective mortars including curing cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No. Sqm 22.00
114/16.36.2)

16.37 KSRB 24.42 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:6 including curing cost of
materials, labour, complete as per specifications. Specifications No. KBS
24.2.1 (PWD SR2009-10/P.No. 114/16.37)

16.37.1 KSRB 24.42 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:6 including curing cost of
materials, labour, complete as per specifications. Specifications No. KBS Sqm 71.00
24.2.1 (PWD SR2009-10/P.No. 114/16.37.1)

16.37.2 KSRB 24.43 : Add from Item No. 24-40, 24-41, 24-42 for every 5mm thick
increase after 10mm with respective mortars including curing cost of
materials, labour, complete as per specifications. (PWD SR2009-10/P.No. Sqm 19.00
114/16.37.2)

16.38 KSRB 24.44 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 145.00
labour, complete as per specifications. Specification No. KBS 24.2.1 (PWD
SR2009-10/P.No. 114-115/16.38)

16.39 KSRB 24.45 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 128.00
labour, complete as per specifications. Specification No. KBS 24.2.1 (PWD
SR2009-10/P.No. 115/16.39)

16.40 KSRB 24.46 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:6 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 112.00
labour, complete as per specifications. Specification No. KBS 24.2.1 (PWD
SR2009-10/P.No. 115/16.40)

ROADS AND BRIDGES - CARRIAGE OF MATERIALS


17.1 KSRRB M 100-1 Loading and Unloading of Stone Boulder/Stone
aggregates/Sand/Kanker/Moorum.
Placing tipper at loading point, loading with front end
leader,dumping,turninig for return trip, excluding time for haulage and cum
return trip complete as per specifications. MORTH Chapter 1 Specification
No. KBS 24.2.1 (PWD SR2009-10/P.No. 117/17.1)
17.2 KSRRB M 100-2 Loading and Unloading of Stone Boulders by Manual
Means complete as per Specification No. KBS 24.2.1 (PWD SR2009- cum
10/P.No. 117/17.2)

17.3 KSRRB M 100-3 Loading and Unloading of Cement Steel by Manual


Means complete as per Specification No. KBS 24.2.1 (PWD SR2009- Tonne
10/P.No. 117/17.3)

17.4 KSRRB M 100-4.1 Cost of Haulage Excluding Loading and Unloading


MORTH Chapter 1 Specification No. KBS 24.2.1 (PWD SR2009-10/P.No. t.km
117/17.4)

17.5 KSRRB M 100-4.2 Haulage of materials by tripper excluding cost of


loading, unloading and stacking complete as per specification No. KBS t.km
24.2.1 (PWD SR2009-10/P.No. 117/17.5)

17.6 KSRRB M 100-4.3 Haulage of materials by tripper excluding cost of


loading, unloading and stacking complete as per specification MORTH No. t.km
KBS 24.2.1 (PWD SR2009-10/P.No. 117/17.6)

17.7 KSRRB M 100-5 Supply of quarried stone, hand breaking into coarse
aggregate 63mm nominal size (passing 80mm and retained on 50mm
sieve) and stacking as directed complete as per specification No. KBS cum 720.00
24.2.1 (PWD SR2009-10/P.No. 117/17.5)

17.8 KSRRB M 100-6 Crushing of stone boulders of 150 mm size in an


integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyer and vibrating
screens to obtain stone aggregates of 13.2 mm nominal size complete. cum 625.00
MORTH Chapter 1 as per specification No. KBS 24.2.1 (PWD SR2009-
10/P.No. 117/17.8)

17.9 KSRRB M 100-7 Crushing of stone boulders of 150 mm size in an


integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyer and vibrating
screens to obtain stone aggregates of 20 mm nominal size complete. cum 560.00
MORTH Chapter 1 as per specification No. KBS 24.2.1 (PWD SR2009-
10/P.No. 117/17.9)

17.10 KSRRB M 100-8 Crushing of stone boulders of 150 mm size in an


integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyer and vibrating
screens to obtain stone aggregates of 40 mm nominal size complete. cum 500.00
MORTH Chapter 1 as per specification No. KBS 24.2.1 (PWD SR2009-
10/P.No. 117/17.10)

ROADS AND BRIDGES - SITE CLEARENCE AND DISMANTLING

Sl. No. Description Unit Rate

18.1 KSRRB -200-1.1 : Cutting of trees girth from 300mm to 600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres, earth filling in the depressions/ pit,
labour charges complete as per specifications. Specification No. KRBS Each 101.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.1)
18.2 KSRRB -200-1.2 : Cutting of trees girth from 600mm to 900mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 203.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.2)

18.3 KSRRB -200-1.3 : Cutting of trees girth from 900mm to 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 500.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.3)

18.4 KSRRB -200-1.4 : Cutting of trees girth from 1800mm to 2700mm


including cutting of trunks, branches and removal of stumps stacking of
serviceable materials within a lead of 100 metres and earth filling in the
depressions/ pit, labour charges complete as per specifications. Each 840.00
Specification No. KRBS 200-1, MORT & H Specification No. 201. (PWD
SR2009-10/P.No.119/18.4)

18.5 KSRRB -200-1.4 : Cutting of trees girth from above 2700mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS 2020.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.5)

18.6 KSRRB -200-1.5 : Cutting of trees girth from 300mm to 600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 123.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.6)

18.7 KSRRB -200-1.5 : Cutting of trees girth from 600mm to 900mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS 215.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.7)

18.8 KSRRB -200-1.5 : Cutting of trees girth from 900mm to 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS 420.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.8)

18.9 KSRRB -200-1.5 : Cutting of trees girth from above 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS 810.00
200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.9)
18.10 KSRRB -200-2.1 : Clearing grass and removal of rubbish by manual
means upto a distance of 50 metres outside th periphery of the area
cleaned labour charges complete as per specifications. Specification No. Ha 8700.00
KRBS 200-1, MORT & H Specification No. 201. (PWD SR2009-
10/P.No.119/18.10)

18.11 KSRRB -200-8 : Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300mm,
by manual means, in area of light jungle, removal of stumps, disposal of
unserviceable materials, stacking of serviceable materials within a lead of
Sqm 3.30
100 metres from road boundary, lablour charges complete as per
specifications. Specification No. KRBS 200-1, MORT & H Specification
No. 201. (PWD SR2009-10/P.No.119/18.11)

18.12 KSRRB -200-9 : Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300mm,
by manual means, in area of thorny jungle, removal of stumps, disposal
of unserviceable materials, stacking of serviceable materials within a lead Sqm 5.00
of 100 metres from road boundary, lablour charges complete as per
specifications. Specification No. KRBS 200-1, MORT & H Specification
No. 201. (PWD SR2009-10/P.No.119/18.12)

18.13 KSRRB -200-3.3 : Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, by machanical means, in area of light jungle and thorny jungle,
removal of stumps, disposal of unserviceable materials, stacking of
serviceable materials within a lead of 1000 metres including removal and Ha 26300.00
disposal of top organic soil not exeeding 150mm in thickness comlete as
per specifications. In area of light jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2009-10/P.No.119/18.13)

18.14 KSRRB M 200-10.2 Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, removal of stumps, of trees cut earlier and disposal of
unserviceable materials, stacking of serviceable materials to be used or
auctioned, up to a lead of 1000 metres including removal and disposal of 35200.00
top organic soil not exeeding 150mm in thickness comlete as per
specifications. In area of thorny jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2009-10/P.No.119/18.14)

18.15 KSRRB M 200-10.2 Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, removal of stumps, of trees cut earlier and disposal of
unserviceable materials, stacking of serviceable materials to be used or
auctioned, up to a lead of 1000 metres including removal and disposal of
Ha 19650.00
top organic soil not exeeding 150mm in thickness comlete as per
specifications. In area of thorny jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2009-10/P.No.120/18.15)In
area of light jungle

18.16 KSRRB M 200-11.2 Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, removal of stumps, of trees cut earlier and disposal of
unserviceable materials, stacking of serviceable materials to be used or
auctioned, up to a lead of 1000 metres including removal and disposal of
Ha 23850.00
top organic soil not exeeding 150mm in thickness comlete as per
specifications. In area of thorny jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2009-10/P.No.120/18.14) In
area of thorny jungle
18.17 KSRRB -200-12.1: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
cum 180.00
metres complete as per specifications. i) Lime/Cement Concrete. I.By
Manual meance: A. Lime Concrete, cement concrete grade M-10 and
below Morth Specification No. KRBS 200-2, MORT & H Specification No.
202. (PWD SR2009-10/P.No.120/18.17)

18.18 KSRRB -200-12.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. i) Lime/Cement Concrete. I.By cum 215.00
Manual meance: B. Cement Concrete grade. cement concrete grade M-15
& M-20 and below Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.120/18.18)

18.19 KSRRB -200-12.3: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. i) Lime/Cement Concrete. I.By cum 560.00
Manual meance: C. Prestressed/Reinforced cement concrete grade M-20
and above Specification No. KRBS 200-2, MORT & H Specification No.
202. (PWD SR2009-10/P.No.120/18.19)

18.20 KSRRB -200-13.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. ii) By Mechanical meance. A. cum 305.00
Cement Concrete. I.By Manual meance: C. Prestressed/Reinforced
cement concrete grade M-15 & M-20 and above Specification No. KRBS
200-2, MORT & H Specification No. 202. (PWD SR2009-
10/P.No.120/18.20)

18.21 KSRRB -200-13.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. ii) By Mechanical meance. A. cum 490.00
Cement Concrete. I.By Manual meance: C. Prestressed/Reinforced
cement concrete grade M-15 & M-20 and above Specification No. KRBS
200-2, MORT & H Specification No. 202. (PWD SR2009-
10/P.No.120/18.21)

18.22 KSRRB -200-14.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 110.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. A.
In lime morter.Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.120/18.22)
18.23 KSRRB -200-14.2: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 145.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. B.
In cement morter.Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.120/18.23)

18.24 KSRRB -200-14.3: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 97.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. C.
In mud morter.Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.120/18.24)

18.25 KSRRB -200-14.4: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
cum 90.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. D.
Dry brick pitching or brick soiling orter.Morth Specification No. KRBS 200-
2, MORT & H Specification No. 202. (PWD SR2009-10/P.No.120/18.25)

18.26 KSRRB -200-15.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 125.00
metres complete as per specifications. ii)Dismanting Stone Masonry. A.
Rubble Stone masonry in lime mortar..Morth Specification No. KRBS 202
(PWD SR2009-10/P.No.120-121/18.26)

18.27 KSRRB -200-15.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 145.00
metres complete as per specifications. ii)Dismanting Stone Masonry. B.
Rubble Stone masonry in cement mortar..Morth Specification No. KRBS
202 (PWD SR2009-10/P.No.121/18.27)

18.28 KSRRB -200-15.3: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 110.00
metres complete as per specifications. ii)Dismanting Stone Masonry. C.
Rubble Stone masonry in mud mortar..Morth Specification No. KRBS 202
(PWD SR2009-10/P.No.121/18.28)
18.29 KSRRB -200-15.4: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 104.00
metres complete as per specifications. ii)Dismanting Stone Masonry. D.
Dry rubble masonry Morth Specification No. KRBS 202 (PWD SR2009-
10/P.No.121/18.29)

18.30 KSRRB -200-15.5: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 97.00
metres complete as per specifications. ii)Dismanting Stone Masonry. E.
Dismanting stone pitching/dry stone spalls. Morth Specification No. KRBS
202 (PWD SR2009-10/P.No.121/18.30)

18.31 KSRRB -200-15.6: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 110.00
metres complete as per specifications. ii)Dismanting brick tile work. F.
Dismanting Boulders laid in wire crates including opening of crates and
stacking dismantled materials. Morth Specification No. KRBS 202 (PWD
SR2009-10/P.No.121/18.31)

18.32 KSRRB -200-16: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 250.00
metres complete as per specifications. iv)Dismanting wood work wrought
framed and fixed in frames of trusses upto a Height of 5 m above Pilnth
Level. Morth Specification No. KRBS 202 (PWD SR2009-
10/P.No.121/18.32)

18.33 KSRRB -200-17.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
Tonne 650.00
metres complete as per specifications. v)Steel work in all types of Section
upto a Height of 5 m above plinth level excluding Cutting of Rivet.-A.
Including dismembering." Specification No. KRBS 202 (PWD SR2009-
10/P.No.121/18.31)

18.34 KSRRB -200-17.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 Tonne 500.00
metres complete as per specifications. v)Steel work in all types of Section
upto a Height of 5 m above plinth level excluding Cutting of Rivet.-
A.Excluding dismembering." No. KRBS 202 (PWD SR2009-
10/P.No.121/18.34)
18.35 KSRRB -200-17.2: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 RIVET 4.50
metres complete as per specifications. B for Cutting of Rivets.
Specification No. KRBS 202 (PWD SR2009-10/P.No.121/18.35)

18.36 KSRRB -200-18.1 : vi) Scraping of bricks dismantled from brick work
including Stacking - A.In Lime/Cement mortar. Specification No. KRBS
200-2, MORT & H Specification No. 202. (PWD SR2009- Nos. 0.60
10/P.No.121/18.36)

18.37 KSRRB -200-18.2 : Scraping of bricks dismantled from brick work in mud
mortar and stacking including cost of all labour charges complete as per
specifications. Specification No. KRBS 200-2, MORT & H Specification No. Nos. 20.00
202. (PWD SR2009-10/P.No.121/18.37)

18.38 KSRRB -200-19.1 : Scraping of Stones dismantled from stone masonry in


cement / lime mortar and stacking including cost of all labour charges
complete as per specifications. Specification No. KRBS 200-2, MORT & H Cum 244.00
Specification No. 202. (PWD SR2009-10/P.No.121/18.38)

18.39 KSRRB -200-19.2 : Scraping of Stones dismantled from stone masonry in


mud mortar and stacking including cost of all labour charges complete as
per specifications. Specification No. KRBS 200-2, MORT & H Specification Cum 51.50
No. 202. (PWD SR2009-10/P.No.121/18.39)

18.40 KSRRB -200-20 : Scrapping plaster in lime or cement mortar from


brick/stone masonry. as per specifications. Specification No. KRBS 200-2, Sqm 7.50
MORT & H Specification No. 202. (PWD SR2009-10/P.No.121/18.40)

18.41 KSRRB -200-21.1 : Removing all types of hume pipes and stacking within
a lead of 1000 metres including earthwork and dismanting of masonary
works.A. Upto 600 mm dia. Specification No. KRBS 200-2, MORT & H m 90.00
Specification No. 202. (PWD SR2009-10/P.No.121/18.41)

18.42 KSRRB -200-21.2 : Removing all types of hume pipes and stacking within
a lead of 1000 metres including earthwork and dismanting of masonary
works.B. Above 600 mm to 900 mm dia. Specification No. KRBS 200-2, m 122.00
MORT & H Specification No. 202. (PWD SR2009-10/P.No.121/18.42)

18.43 KSRRB -200-21.3 : Removing all types of hume pipes and stacking within
a lead of 1000 metres including earthwork and dismanting of masonary
works.C. Above 900 mm dia. Specification No. KRBS 200-2, MORT & H m 209.00
Specification No. 202. (PWD SR2009-10/P.No.121/18.43)

18.44 KSRRB -200-22.1 : Dismanting of flexible pavements and disposal of


dismantled materials upto a lead of 1000 metres, stacking serviceable and
unserviceable materials seperately complete as per Specification. A. cum 330.00
Bituminous courses. No. KRBS 200-2, MORT & H Specification No. 202.
(PWD SR2009-10/P.No.122/18.44)

18.45 KSRRB -200-22.2 : Dismanting of flexible pavements and disposal of


dismantled materials upto a lead of 1000 metres, stacking serviceable and
unserviceable materials seperately complete as per Specification. A. cum 235.00
Granular courses. No. KRBS 200-2, MORT & H Specification No. 202.
(PWD SR2009-10/P.No.122/18.45)
18.46 KSRRB -200-23.1 : Dismanting of flexible pavements and disposal of
dismantled materials upto a lead of 1000 metres, stacking serviceable and
unserviceable materials seperately complete as per Specification. cum 125.00
Mechanical Meance A. Bituminous courses. No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.122/18.46)

18.47 KSRRB -200-24 : Dismanting of cement concrete pavement by


mechanical meance using penumatic tools, breaking to pieces not
exceeding 0.02 cum in volume and stock piling at designated locations and
disposal of dismantled materials upto a lead of 1000 metres, stacking cum 640.00
serviceable and unserviceable materials seperately complete as per
Specification. No. KRBS 200-2, MORT & H Specification No. 202. (PWD
SR2009-10/P.No.122/18.47)

18.48 KSRRB -200-25 : Dismanting of guard rails by manual means and


disposal of dismantled materials with all lifts and upto a lead of 1000
metres, stacking serviceable materials and unserviceable materials m 35.00
seperately complete as per Specification. No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.122/18.48)

18.49 KSRRB -200-26: Dismanting kerb stone by manual means and disposal
of dismantled materials with all lifts and upto a lead of 1000 metres,
complete as per Specification. No. KRBS 200-2, MORT & H Specification m 6.50
No. 202. (PWD SR2009-10/P.No.122/18.49)

18.50 KSRRB -200-27 : Dismanting kerb stone channel by manual means


including and disposal of dismantled materials with all lifts and upto a
lead of 1000 metres, complete as per Specification. No. KRBS 200-2, m 9.80
MORT & H Specification No. 202. (PWD SR2009-10/P.No.122/18.50)

18.51 KSRRB -200-28.1 : Dismanting of kilometre stone including cutting of


earth, foundation and disposal of dismantled materials with all lifts and
upto a lead of 1000 metres, and back filling of pit complete as per
Specification. A. 5th KM stone (quantity of cement concrete = 0.392 cum ) Each 175.00
No. KRBS 200-2, MORT & H Specification No. 202. (PWD SR2009-
10/P.No.122/18.51)

18.52 KSRRB -200-28.2 : Dismanting of kilometre stone including cutting of


earth, foundation and disposal of dismantled materials with all lifts and
upto a lead of 1000 metres, and back filling of pit complete as per
Specification. B. Ordinary KM stone (quantity of cement concrete = 0.269 Each 106.00
cum ) No. KRBS 200-2, MORT & H Specification No. 202. (PWD SR2009-
10/P.No.122/18.52)

18.53 KSRRB -200-28.3 : Dismanting of kilometre stone including cutting of


earth, foundation and disposal of dismantled materials with all lifts and
upto a lead of 1000 metres, and back filling of pit complete as per
Specification. B. Hectometre stone (quantity of cement concrete = 0.048 Each 21.00
cum ) No. KRBS 200-2, MORT & H Specification No. 202. (PWD SR2009-
10/P.No.122/18.53)

18.54 KSRRB -200-29: Dismanting of barbed wire fencing / wire mesh fencing
including posts, foundation concrete, back filling of pit by manual meance
including disposal of dismantled materials with all lifts and upto a lead of
1000 metres, stacking serviceable materials and unserviceable materials m 22.00
seperately complete as per Specification.No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2009-10/P.No.122/18.54)
18.55 KSRRB -200-30: Dismanting of CI water pipe line 600 mm dia including
disposal with all lifts and lead of 1000 metres, and stacking serviceable
materials and unserviceable material seperately under supervision of m 60.00
concerned department complete as per Specification.No. KRBS 200-2,
MORT & H Specification No. 202. (PWD SR2009-10/P.No.123/18.55)

18.56 KSRRB -200-31: Removal of cement concrete pipe of sewer guttrt 1500
mm dia under the supervision of concerned department including
disposal with all lifts and up to lead of 1000 metres, and stacking
serviceable materials and unserviceable material seperately but excluding m 86.00
earth excavation and dismantling of masonry work complete as per
Specification.No. KRBS 200-2, MORT & H Specification No. 202. (PWD
SR2009-10/P.No.123/18.56)

18.57 KSRRB -200-32: Removal of Telephone / Electric poles including


excavation and dismantling of foundation concrete and lines under the
supervision of concerned department, disposal with all lifts and up to lead
of 1000 metres, and stacking serviceable materials and unserviceable Nos 79.00
material seperately complete as per Specification.No. KRBS 200-2,
MORT & H Specification No. 202. (PWD SR2009-10/P.No.123/18.57)

EARTH WORK FOR ROADS


2008-2009
Sl. Description Rate
Unit
No. Rs. Ps.

19.1 KSRRB -300-1.2 : Earthwork excavation by manual means in ordinary soil


involving an average horizontal throw upto 2 meters and an average lift
upto 0.5m, excavated surface levelled and sides neatly dressed, the
disposed earth to be levelled neatly, after breaking of clods complete as Cum 44.00
per specifications. Specification No. KRBS 300-1, MORT & H
Specification No. 301 to 305. (PWD SR2009-10/P.No.125/19.1)

19.2 KSRRB -300-1.2 : Earthwork excavation by manual means in hard soil


involving an average horizontal throw upto 2 meters and an average lift
upto 0.5m, excavated surface levelled and sides neatly dressed, the
disposed earth to be levelled neatly, after breaking of clods complete as Cum 60.00
per specifications. Specification No. KRBS 300-1, MORT & H
Specification No. 301 to 305. (PWD SR2009-10/P.No.125/19.2)

19.3 KSRRB -300-3 : Earth excavation and Formation of road embankment by


manual means ordinary soil with initial lead upto 15 m and lift of 1.5 m
(when earth is taken from bank cutting or from borrow pits ) including
breaking of clods, spreading to required line and level, forming and cost of Cum 55.00
all labour complete as per specifications. (excluding watering and
compaction of earth) Specification No. KRBS 300-1, 300-5 MORT & H
Specification No. 301 to 305. (PWD SR2009-10/P.No.125/19.3)

19.4 KSRRB -300-3 : Earth excavation and Formation of road embankment by


manual means hard soil with initial lead upto 15 m and lift of 1.5 m (when
earth is taken from bank cutting or from borrow pits ) including breaking of
clods, spreading to required line and level, forming and cost of all labour Cum 84.00
complete as per specifications. (excluding watering and compaction of
earth) Specification No. KRBS 300-1, 300-5 MORT & H Specification No.
301 to 305. (PWD SR2009-10/P.No.125/19.4)
19.5 KSRRB -300-5 : Excavation in soft rock with blasting for formation of
roads including stacking neatly, to uniform line and level with an initial lead
upto 15m. cost of explosives, labour, HOM of machineries and equipments
complete as per specifications. Specification No. KRBS 300-1, 300-5, Cum 230.00
MORT & H Specification No. 301 to 305. (PWD SR2009-
10/P.No.125/19.5)

19.6 KSRRB -300-2.4 : Excavation in soft rock without blasting for formation
of roads including stacking neatly, to uniform line and level with an initial
lead upto 15m. cost of all labour, equipment, complete as per Cum 400.00
specifications. Specification No. KRBS 300-1, 300-5, MORT & H
Specification No. 301 to 305. (PWD SR2009-10/P.No.125/19.6)

19.7 KSRRB -300-7: Excavation in hard rock by blasting for formation of roads
including stacking to uniform line and level with an initial lead upto 15m.
and lift upto 1.5m, as directed by the engineer including cost of explosives,
labour, HOM of machineries and equipments complete as per Cum 315.00
specifications. Specification No. KRBS 300-1, 300-2, MORT & H
Specification No. 302 (PWD SR2009-10/P.No.125/19.7)

19.8 KSRRB -300-8 : Excavation in hard rock by chiselling and / or wedging


where blasting is prohibited for formation of roads including stacking to
uniform line and level with an initial lead upto 15m. cost of all labour Cum 605.00
complete as per specifications. Specification No. KRBS 300-1, MORT & H
Specification No. 305 (PWD SR2009-10/P.No.125/19.8)

19.9 KSRRB -300-9 : Excavation for roadway in soil using manual means
including loading in truck for carrying of cut earth to embankment site with
all lifts and lead upto 1000 metres Complete as per specifications. KSRB Cum 89.00
300-1 MORTH Specification No. 301 to 305 (PWD SR2009-
10/P.No.125/19.9)

19.1 KSRRB -300-10 : Excavation in ordinary rock using manual means


including loading in truck and carrying of excavated material to
embankment site with all lifts and lead upto 1000 metres Complete as per cum 125.00
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2009-10/P.No.125/19.10)

Excavation in Soil with Dozer with lead upto 100 metres.


19.11 KSRRB -300-11 : Excavation for roadway in soil by mechanical means
including cutting and pushing the earth to site of embankment upto a
distance of 1000 metres (average lead 50 metres) including trimming
bottom and side slopes in accordance with requirements of lines, grade cum 64.00
and cross sections Complete as per specifications. KSRB 300-1 MORTH
Specification No. 301 (PWD SR2009-10/P.No.126/19.11)

Excavation in Ordinary Rock with Dozer with lead upto 100 metres
19.12 KSRRB -300-12 : Excavation for roadway in ordinary rock by deploying a
dozer, 80 HP including cutting and pushing the cut earth to site of
embankment upto a distance of 100 metres (average lead 50 metres)
trimming bottom and side slopes in accordance with the requirements of cum 109.00
lines, grades and cross sections Complete as per specifications. KSRB
300-1 MORTH Specification No. 301 (PWD SR2009-10/P.No.126/19.12)

Excavation in Hard Rock (requiring blasting) with disposal upto 1000


metres
19.13 KSRRB -300-13 : Excavation for roadway in hard rock by (requiring
blasting) by drilling, blasting and breaking, trimming of bottom and side
slopes in accordance with the requirements of lines, grades and cross
sections, loading and disposal of cut road with in all lifts and leads upto cum 295.00
1000 metres Complete as per specifications. KSRB 300-1 MORTH
Specification No. 301 (PWD SR2009-10/P.No.126/19.13)

Excavation in Soil using Hydraulic Excavation CK 90 and Tippers


with Disposal upto 1000 metres
19.14 KSRRB -300-14 : Excavation for roadway in soil with hydraulic excavator
of 0.9 cum bucket capacity including cutting and loading in tippers
trimming bottom and side slopes in accordance with the requirements of
lines, grades and cross sections, and transporting to the embankment cum 33.00
location with in all lifts and leads upto 1000 metres Complete as per
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2009-10/P.No.126/19.14)

Excavation in Ordinary Rock using Hydraulic Excavator CK-90 and


Tippers with Disposal upto 1000 metres.
19.15 KSRRB -300-15 : Excavation for roadway in ordinary rockl with hydraulic
excavator of 0.9 cum bucket capacity including cutting and loading in
tippers transporting to the embankment site with in all lifts and leads upto
1000 metres trimming bottom and side slopes in accordance with cum 44.00
requirements of lines, grades and cross sections Complete as per
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2009-10/P.No.126/19.15)

Excavation in Hard Rock (blasting prohibited)


19.16 KSRRB -300-16.1 : Excavation for roadway in hard rock by ( blasting
prohibited) with Rock breakers including breaking rock, loading in tippers
and disposal within all lifts and leads upto 1000 metres trimming bottom
and side slopes in accordance with requirements of lines, grades and cum 182.00
cross sections Complete as per specifications. A. Mechanised KSRB 300-
1 MORTH Specification No. 301 (PWD SR2009-10/P.No.126/19.16)

Excavation in Hard Rock (blasting prohibited)


19.17 KSRRB -300-16.2 : Excavation for roadway in hard rock by ( blasting
prohibited) with Rock breakers including breaking rock, loading in tippers
and disposal within all lifts and leads upto 1000 metres trimming bottom
and side slopes in accordance with requirements of lines, grades and cum 375.00
cross sections Complete as per specifications. B. Manual Method. KSRB
300-1 MORTH Specification No. 301 (PWD SR2009-10/P.No.127/19.17)

19.18 KSRRB -300-17 : Excavation for roadway in hard rock ( controlled blasting
) with Rock breakers including breaking rock, loading in tippers
trancporting to embankment site within all lifts and leads upto a distance
of 1000 metres trimming bottom and side slopes in accordance with cum 330.00
requirements of lines, grades and cross sections Complete as per
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2009-10/P.No.127/19.18)

Excavation in Marshy Soil


19.19 KSRRB -300-18 : Excavation for roadway in marshy soil with hydraulic
excavator of 0.9 cum bucket capacity including cutting and loading in
tippers and disposal with in all lifts and leads upto 1000 metres trimming
bottom and side slopes in accordance with requirements of lines, grades cum 38.00
and cross sections Complete as per specifications. KSRB 300-1 MORTH
Specification No. 301 (PWD SR2009-10/P.No.127/19.19)
Removal of Unserviceable Soil with Disposal upto 1000 metres.
19.20 KSRRB -300-19 : Removal of Unserviceable soil including excavation,
loading and disposal upto 1000 metres lead but excluding replacement by
suitable soil which shall be paid separately as per clause 300.5 Complete cum 34.00
as per specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2009-10/P.No.127/19.20)

Presplitting of Rock Excavation Slopes.


19.21 KSRRB -300-20 :Carrying out excavation in hord rock to achieve a
specified slope of the rock face by controlled use of explosives and
blasting accessories in properly aligned and spaced drill holes, collection
of the excavated rock by a 80 HP dozer,loading in tripper by a front end
loader and disposing of the material with all lifts and lead upto 1000m, all Sqm 80.00
as specified in clause No. 300.3 Complete as per specifications. KSRB
300-1 MORTH Specification No. 303 (PWD SR2009-10/P.No.127/19.21)

Excavation for Structures.


19.22 KSRRB -300-21.1 : Earth work in excavation of foundation of structures as
per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 139.00
as per specifications. i) Ordinary Soil-A. Manual Means (i) Depth upto 3m
KSRB 300-1 MORTH Specification No. 304 (PWD SR2009-
10/P.No.127/19.22)

19.23 KSRRB -300-21.2 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 28.00
as per specifications. i) Ordinary Soil-A. Mechanical Means (i) Depth upto
3m KSRB 300-1 MORTH Specification No. 304 (PWD SR2009-
10/P.No.127/19.23)

19.24 KSRRB -300-22.1 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 174.00
as per specifications. ii) Ordinary Rock (not requiring blasting) -A.Manual
Means (i) Depth upto 3m KSRB 300-1 MORTH Specification No. 304
(PWD SR2009-10/P.No.128/19.24)

19.25 KSRRB -300-22.2 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 38.00
as per specifications. ii) Ordinary Rock (not requiring blasting)
-B.Mechanicall Means (i) Depth upto 3m KSRB 300-1 MORTH
Specification No. 304 (PWD SR2009-10/P.No.128/19.25)
19.26 KSRRB -300-23 : Earth work in excavation of foundation of structures as
per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 310.00
as per specifications. ii) Hord Rock (requiring blasting) -A.Manual Means
(i) Depth upto 3m KSRB 300-1 MORTH Specification No. 304 (PWD
SR2009-10/P.No.128/19.26)

19.27 KSRRB -300-24 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 440.00
as per specifications. iv) Hord Rock ( blasting prohibited) -A.Mechanical
Means KSRB 300-1 MORTH Specification No. 304 (PWD SR2009-
10/P.No.128/19.27)

19.28 KSRRB -300-25.2 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 240.00
as per specifications. v) Marshy Soil A.Mechanical Means i) upto 3m
depth KSRB 300-1 MORTH Specification No. 304 (PWD SR2009-
10/P.No.128/19.28)

19.29 KSRRB -300-25.3: Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 68.00
as per specifications. vi) Marshy Soil B.Mechanical Means i) upto 3m
depth KSRB 300-1 MORTH Specification No. 304 (PWD SR2009-
10/P.No.128/19.29)

KSRRB 300-Extra additional lead


19.30 KSRRB -300-26.1: Extra for every 7.5 m additional lead beyond 15m but
upto 60m by manual means for all kinds of soils except hard rock including
cost of all labour complete as pwe specifications KSRB 300-1 MORTH cum 1.80
Specification No. 304 (PWD SR2009-10/P.No.128/19.30)

19.31 KSRRB -300-26.2: When lead is more than 60m upto 500m by any means
of conveyance including loading and unloading for all kinds of soils except
hard rock including cost of all labour complete as per specification. KSRB cum 2.15
300-1 MORTH Specification No. 304 (PWD SR2009-10/P.No.128/19.31)

19.32 KSRRB -300-27: Dressing of earthwork including cutting and filling upto 15
cms thick or depth including cost of all labour complete as per
specification. KSRB 300-1 MORTH Specification No. 304 (PWD cum 22.00
SR2009-10/P.No.128/19.32)

19.33 KSRRB -300-28 : Box cutting / trenching the sub grade to proper slope,
camber and removing inequalities including removing the stuff and
depositing on the road side slopes (cutting of earthwork shall be paid
seperately in the respective item on thebasis of classification of the Sqm 0.50
excavation) including cost of all labour complete as per specifications.
Specification No. KRBS 300-1. MORT & H Specification No. 301 to 305.
(PWD SR2009-10/P.No.128/19.33)
KSRRB M300-Stripping and Storing of top soil
19.34 KSRRB -300-29 : Stripping, Storing of top soil by road side at 15 internal
and re-application on embankment slopes. Cut slopes and other areas in
localities where the aailable ambankment materila is notconducive to plant cum 105.00
growth complete as per specifications. Specification No. Specification No.
301 to 305. (PWD SR2009-10/P.No.128/19.34)

KSRRB M300-Stripping, Storing and Re-laying Top soil from Borrow


Areas in Agriculture Fields.
19.35 KSRRB -300-30 : Stripping, Storing and Re-laying top soil from Borrow
Areas in Agriculture Fields. Stripping of top soil from borrow areas located
in agriculture fields, storing at a suitable place, spreading and re-laying
after taking the borrow earth to maintain fertility of the agricultural field. cum 39.00
finishing it to the required levels and satisfaction of the farmer complete as
per specifications. Specification No. Specification No. 301 to 305. (PWD
SR2009-10/P.No.128-129/19.35)

KSRRB M300-Turfing with Sods/Seeding and Mulching


19.36 KSRRB -300-31 : Turfing with Sods-Furnishing and laying of the live sods
of perenial turf forming grass on embankment slope, verges or other
locations shown on the drawing or as directed by the Engineer including
preparation of ground, fetching of sods and watering. complete as per Sqm 16.00
specifications. Specification No. Specification No. 301 to 307. (PWD
SR2009-10/P.No.129/19.36)

19.37 KSRRB -300-32 : Preparation of seed bed on previously laid top soil,
furnishing and placing of seeds, fertilizer, mulchjing material, applying
bituminious emulsion at the rate of 0.23 litres per swm and laying and
fixing jutee netting, including watering for 3 months all as per Clause 308 Sqm 59.00
complete as per specifications. Specification No. Specification No. 301 to
308. (PWD SR2009-10/P.No.128-129/19.37)

KSRRB M300-Surface Drains in Soil/Rock


19.38 KSRRB -300-33.1 : Construction of unlined surface drain of average cross
sectional area 0.40 sqm in soil to specified lines,grades,levels and
dimensions to the requirement of Clauses 300.1 and 300.9. Excavated
material to be used in embankment within a lead of 50 metres (average m 44.00
lead 25 metres) complete as per specifications. A. Mechanical Means
Specification No. Specification No. 309. (PWD SR2009-10/P.No.128-
129/19.37)

19.39 KSRRB -300-33.2 : Construction of unlined surface drain of average cross


sectional area 0.40 sqm in soil to specified lines,grades,levels and
dimensions to the requirement of Clauses 300.1 and 300.9. Excavated
material to be used in embankment within a lead of 50 metres (average m 34.00
lead 25 metres) complete as per specifications.B. Manual Means
Specification No. Specification No. 309. (PWD SR2009-10/P.No.128-
129/19.37)

KSRRB M300-34 Surface Drains in Ordinary Rock


19.40 KSRRB -300-34.1 : Construction of unlined surface drain of average cross
sectional area 0.40 sqm in Ordinary rock to specified lines,grades,levels
and dimensions as per approved design and to the requirement of Clauses
300.1 and 300.9. Excavated material to be used in embankment site m 89.00
complete as per specifications. A. Mechanical Means Specification No.
Specification No. 309. (PWD SR2009-10/P.No.128-129/19.40)

KSRRB M300- Surface Drains in Ordinary Rock


19.41 KSRRB -300-34.2 : Construction of unlined surface drain of average cross
sectional area 0.40 sqm in Ordinary rock to specified lines,grades,levels
and dimensions as per approved design and to the requirement of Clauses
300.1 and 300.9. Excavated material to be used in embankment site m 52.00
complete as per specifications. B. Manual Means Specification No.
Specification No. 309. (PWD SR2009-10/P.No.128-129/19.41)

KSRRB M300- Sub-Surface Drains with Perforated Pipe.


19.42 KSRRB -300-36 : Construction sub-surface drain th perforated pipe of 100
mm internal diametere of metal/asbestos cement/ cement concrete/ PVC,
closely jointed, perforations ranging from 3mm to 6mm depnding upon
size of material surrounding the pipe, with 150mm bedding below the pipe
and 300mm causion above the pipe, cross-section of excavation m 445.00
450x550mm. Excavated material to be utilised in roadway at site complete
as per specifications. MORTH Specification No. Specification No. 309.
(PWD SR2009-10/P.No.129-130/19.42)

KSRRB M300-Aggregate Sub-Surface Drains.


19.43 KSRRB -300-37 : Construction of aggregate sub-surface drain
300mmx450mm with aggregate conforming to Table 300-4, excavated
material to be utilised in roadway complete as per specifications. MORTH m 142.00
Specification No. Specification No. 309. (PWD SR2009-10/P.No.129-
130/19.42)

KSRRB M300-Underground Drain at Edge of Pevment .


19.44 KSRRB -300-38 : Construction of Underground Drain 1 m x 1 m (inside
Dimensions) lined with RCC 15 cm thick and covered with RCC slab 10 cm
in thickness on urban Roads ( rates of these itmes may be taken from
chapters on earth work and sub structures respectively) complete as per m 2110.00
specifications. MORTH Specification No. Specification No. 309. (PWD
SR2009-10/P.No.130/19.44)

KSRRB M300-Preparation and surface treatment of formation


19.45 KSRRB -300-39 : Preparation and surface treatment of formation by
removing mud and slurry, watering to the extent needed to maintain the
disired moisture content, trimming to the required line, grade profil and
rolling with 8 - 10 tonne smoth sheeled roller, complete as per Caluse 310. Sqm 1.10
complete as per specifications.MORTH Specification No. 301. (PWD
SR2009-10/P.No.130/19.45)

KSRRB M300- Earth work on Hill Road


19.46 KSRRB -300-40 : Excavation in Hilly areas in soil by mechnical means
excavation soil in hilly areas by mechanical means including cutting and
trimming of side slopes and disposing of excavated eath with all lifts and Cum 77.00
leed up to 1000 meters complete as per specifications.MORTH
Specification No. 301. (PWD SR2009-10/P.No.130/19.46)

19.47 KSRRB -300-41 : Excavation in Hilly areas in Ordinary Rock by mechnical


means not requiring Blasting. excavation in hilly area in Ordinary Rock not
requring blasting by mechanical means including cutting and trimming of
slopes and disposal of cut material with all lifts and leed up to 1000 Cum 117.00
meters complete as per specifications.MORTH Specification No. 301.
(PWD SR2009-10/P.No.130/19.47)

19.48 KSRRB -300-42 : Excavation in Hilly areas in Hard Rock requiring


Blasting. excavation in hilly area in Hard Rock requring blasting by
mechanical means including trimming of slopes and disposal of cut
material with all lifts and leed up to 1000 meters complete as per Cum 210.00
specifications.MORTH Specification No. 301. (PWD SR2009-
10/P.No.130/19.48)
KSRRB M300- Scarifying the surface and dressing
19.50 KSRRB -300-44 : Scarifying top bituminous surface or surface dressing or
premix carpet including picking up scarified materials, stacking of old
serviceabale materials with in lead of 100 m by manual means including Sqm 13.00
cost of all labour charges complete as per specifications.MORTH
Specification No. 301. (PWD SR2009-10/P.No.131/19.50)

19.51 KSRRB -300-45 : Scarifying stone metal crust 50mm to 100mm thick with
pick axes along with premix carpet / surface dressing and stacking of old
serviceable materials with in a lead top bituminous surface or surface
dressing or premix carpet including picking up scarified materials, stacking
of old serviceabale materials with in lead of 100 m by manual means Sqm 27.00
including cost of all labour charges complete as per
specifications.MORTH Specification No. 301. (PWD SR2009-
10/P.No.131/19.51)

19.52 KSRRB -300-46 : Scarifying stone metal crust 50mm to 100mm thick by
road roller with scarifier along with 20mm pre mix corpet / surface dressing
and stacking of old serviceable materials with in a lead of 100 m including
cost of all labour charges complete as per specifications.MORTH Sqm 19.00
Specification No. 301. (PWD SR2009-10/P.No.131/19.52)

19.53 KSRRB -300-47 : Scarifying Kankar / gravel / metal crust up to 150mm


thick with pick axes and disposal of stuff with in a lead of 100 m including
cost of all labour charges complete as per specifications.MORTH Sqm 13.00
Specification No. 301. (PWD SR2009-10/P.No.131/19.53)

19.54 KSRRB -300-48 : Scarifying Kankar / gravel / metal crust up to 150mm


thick with power roller and scarifier disposal of stuff with in a lead of 100 m
including cost of all labour charges HOM, of machineries complete as per Sqm 11.00
specifications.MORTH Specification No. 301. (PWD SR2009-
10/P.No.131/19.54)

19.55 KSRRB -300-49 : Scarifying bituminous course 50mm to 75mm thick along
with premix carpet / surface dressing by manula means with out disturbing
the base and stacking of the debries materils with in a lead of 100 m
including cost of all labour charges complete as per specifications.MORTH Sqm 30.00
Specification No. 301. (PWD SR2009-10/P.No.131/19.55)

19.56 KSRRB -300-50 : Scarifying bituminous course 50mm to 75mm thick along
with premix carpet / surface dressing by road roller attached with scarifier
with out disturbing the base and stacking of the debries with in a lead of
100 m including cost of all labour charges HOM, of machineries complete Sqm 19.00
as per specifications.MORTH Specification No. 301. (PWD SR2009-
10/P.No.131/19.56)

19.57 KSRRB -300-51 : Making 50mm x 50mm furrows at 450 to the centre line
of the road and at 1m interval in the existing thin bituminous wearing
course including sweeping taking out old materials stacking the debries
with in a lead of 100 m cost of all labour charges complete as per Sqm 1.60
specifications.MORTH Specification No. 301. (PWD SR2009-
10/P.No.131/19.57)

KSRRB M300-Scarifying Existing Granular Surface to a Depth of 50


mm by Manual Means
19.58 KSRRB -300-52.1 :Scarifying the existing granular road surface to a depth
of 50 mm and disposal of scarified materials within all lifts and leads upto
1000 m complete as per specifications.MORTH Specification No. 305.4.3. Sqm 11.00
(PWD SR2009-10/P.No.132/19.58)

19.59 KSRRB -300-52.2 :Scarifying the existing bituminious suface to a depth of


50 mm by mechanical means surfacing the existing Bituminious road
surface to a depth of 50 mm and disposal of scarified materials within all Sqm 2.75
lifts and leads upto 1000 m complete as per specifications.MORTH
Specification No. 305.4..3. (PWD SR2009-10/P.No.132/19.59)

KSRRB M300-Construction of Embankment with material gravel /


murrum

19.60 KSRRB -300-53 : Construction of Embankment with approved Material


gravel / murrum with all lifts and leads, transporting to site, spreading,
gradding to required slobe and compacting to meet requirement table 300-
2 complete as per specifications (with includes cost of gravel / murrum, Sqm 185.00
watering charges and compacation by vibratory roller) .MORTH
Specification No. 305(PWD SR2009-10/P.No.132/19.60)

KSRRB M300-Construction of Embankment with material deposited


from roadway cutting .
19.61 KSRRB -300-54 : Construction of Embankment with approved Material
deposited at site from roadway cutting and excavation fro drain and
foundation of other structures graded and compacted to meet requirement
of table 300-2 complete as per specifications (with includes watering Cum 66.00
charges and compacation by vibratory roller) .MORTH Specification No.
305(PWD SR2009-10/P.No.132/19.61)

KSRRB M300- Construction of Sub grade & Earthen Shoulders.

19.62 KSRRB -300-55 : Construction of Sub grade & earthen shoulders material
gravel / murrum with all lifts and leads transporting to site, spreading,
grading to required slope and compacted to meet requirement, of table No.
300-2 complete as per specifications ( including cost of Cum
earth, watering charges and compacation by vibratory roller) .MORTH
Specification No. 305(PWD SR2009-10/P.No.132/19.62)

KSRRB M300-Constructio of Rock fill Embankment.


19.63 KSRRB -300-56 : Construction of Rock fill Embankment with available
broken hard Rock fragments of size not exceeding 300mm laid in layers
not exceeding 500 mm thick including filling of surface voids with stone
spalls, blinding top layers with granular material, rolled with vibratory road
roller, all complete as per clause 313 complete as per specifications Cum 36.00
( including cost of earth, watering charges and compacation by vibratory
roller) .MORTH Specification No. 313(PWD SR2009-10/P.No.132/19.63)

KSRRB M300-Compaction

19.64 KSRRB -300-58 : Compaction of original ground with maximum of 6


passes of 8 to 10 tonnes power roller including filling in depression
occuring during rolling including cost of all labour HOM of machinery Cum 3.00
complete as per specifications. .MORTH Specification No. 305 (PWD
SR2009-10/P.No.133/19.64)
19.65 KSRRB -300-59.1 : Loosening of the ground upto level of 500 mm below
the sub grade level, watered, graded & Compacted in layers to meet
requirment of table 300-2 for sub grade construction complete as per
specifications. case-1: Compacting original ground supporting sub grade Cum 48.00
(which includes watering charges and compaction by vibratory
roller)MORTH Specification No. 305.3.4 (PWD SR2009-
10/P.No.133/19.65)

19.66 KSRRB -300-59.2 : Loosening levelling and compacting original ground


suuporting embankment to facilitate placement of first layer of
embankment, scarified to a depth of 150 mm ,mixed with water at OMC
and then compacted by rolling so as to achieve minimum dry density as
given in Table 300-2 for embankment construction. complete as per Cum 24.00
specifications. case-II: Compacting original ground supporting
embankment (which includes watering charges and compaction by
vibratory roller)MORTH Specification No. 305.3.4 (PWD SR2009-
10/P.No.133/19.66)

19.67 KSRRB -300-60 : Extra for laying earth by manual meance as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done simultaneously with excavation of earth work and
dressing but excluding rolling and watering including cost of all labour. Cum 5.40
complete as per specifications. MORTH Specification No. 305.3.4 (PWD
SR2009-10/P.No.133/19.67)

19.68 KSRRB -300-61 : Extra for laying earth by manual meance as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done from stacked materials including breaking of clods
and dressing but excluding rolling and watering including cost of all labour. Cum 23.00
complete as per specifications. MORTH Specification No. 305.3.4 (PWD
SR2009-10/P.No.133/19.68)

19.69 KSRRB -300-62 : Extra for laying earth by mechanical meance as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done from stacked materials including breaking of clods
and dressing but excluding rolling and watering including cost of all labour. Cum 20.00
HOM of machineries complete as per specifications. MORTH Specification
No. 305.3.4 (PWD SR2009-10/P.No.133/19.68)

19.70 KSRRB -300-63 : Construction of Embankment with Flyash / Pond Ash


available from Coal or Lignite Burning Thermal Plants as Waste Material.
Construction of embankment with flyash conforming to Table 1 of IRS :
SP:58-2001 obtained from coal or lignite burning thermal power stations as
waste material, spread and compacted in layer of 200mm thickness each Cum 75.00
at OMC, all as speicified in IRC:SP-58-2001 and as approved plans
complete as per specifications. (PWD SR2009-10/P.No.133/19.70)

19.71 KSRRB -300-64.1 : Extra for watering thr earth to bring the earth upto
required optimum moisture content manually including cost of all labour
complete as per specifications. MORTH Specification No. 305.3.4 (PWD Cum 4.00
SR2009-10/P.No.134/19.71)

19.72 KSRRB -300-64.2 : Extra for watering thr earth to bring the earth upto
required optimum moisture content with mechinery including cost of all
Cum 2.15
labour, HOM of machineries complete as per specifications. MORTH
(PWD SR2009-10/P.No.134/19.72)
19.73. KSRRB -300-65 : Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired filed density
not less than 95% of maximum dry density ( modified heavy proctor test ) Cum 15.50
including HOM of machineries complete as per specifications. MORTH
(PWD SR2009-10/P.No.134/19.73)

19.74 KSRRB -300-66 : Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired filed density
not less than 100% of maximum dry density ( modified heavy proctor test ) Cum 19.00
including HOM of machineries complete as per specifications. MORTH
(PWD SR2009-10/P.No.134/19.74)

19.75 KSRRB -300-67 : Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired filed density
not less than 100% of maximum dry density ( modified heavy proctor test ) Cum 6.50
including HOM of machineries complete as per specifications. MORTH
(PWD SR2009-10/P.No.134/19.75)

19.76 KSRRB -300-68 : Extra for rolling to specification with power roller 8-10
tonne when earth is at suitable moisture content with desired field density
not less than 100% of maximum dry density ( ordinary proctor test ) Cum 8.00
including HOM of machineries complete as per specifications. MORTH
(PWD SR2009-10/P.No.134/19.76)

KSRRB M300-HORTICULTURE
KSRRB M300-Spreading of sludge farm yard manure or/ and good
earth.
19.77 KSRRB -300-1 : Spreading of sludge farm yard manure or /and good earth
in required thickness (Cost of sludge, farm yard manure or / and good
earth to be paid for separately ) Complete as per specifications No. 307. Cum 34.00
MORTH (PWD SR2009-10/P.No.134/19.77)

KSRRB M300-Grassing with Doobs grass


19.78 KSRRB -300-2.1 : Grassing with Doobs grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn free from weeds and fit for moving including supplying good earth if
needed complete as per specifications. MORTH Specification No.307. Sqm 39.00
i) In rows 15 cm apart in either direction. (PWD SR2009-
10/P.No.134/19.78)

19.79 KSRRB -300-2.2 : Grassing with Doobs grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn free from weeds and fit for moving including supplying good earth if
needed complete as per specifications. MORTH Specification No.307. Sqm 76.00
i) In rows 7.5 cm apart in either direction. (PWD SR2009-
10/P.No.134/19.79)

KSRRB M300-Making lawns including ploughing and dradding with


'swagha' breaking of clod
19.80 KSRRB -300-3 : Making lawns including ploughing and breaking of clod,
removal of rubbish, dressing and supplying doobs grass and planting at 15
cm apart, including supplying and spreading of farm yard manure at Sqm 11.00
MORTH Specification No.307. . (PWD SR2009-10/P.No.135/19.80)

KSRRB M300-Maintenance of lawns or Turfing


19.81 KSRRB -300-4 : Maintenance of lawns or Turfing of slopes (rough
grassing) for a period of one year including watering etc complete as per
specifications. MORTH Specification No. 307 (PWD SR2009- Sqm 84.00
10/P.No.135/19.81)

KSRRB M300-Turfing lawns with fine grassing including ploughing,


dressing
19.82 KSRRB -300-5 : Turfing lawns with fine grassing including ploughing,
dressing including breaking of clods, removal of rubbish, dressing and
supplying doobs grass roots at 10 cm apart, including supplying and
spreading of farm yard manure at rate of 0.6 cum per 100 sqm complete Sqm 14.00
as per specifications. MORTH Specification No. 307(PWD SR2009-
10/P.No.135/19.82)

KSRRB M300- Maintenance of lawns with fine grassing for the first
year
19.83 KSRRB -300-6 :Maintenance of lawns with fine grassing for the first year
including watering etc complete as per specifications. MORTH Sqm 70.00
Specification No. 307. (PWD SR2009-10/P.No.135/19.83)

KSRRB M300-Planting and Maintenance permanent hedges


19.84 KSRRB -300-7.1 : Planting permanent hedges including diggid of
trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed
with farmyard manure, supplied at the rate of 4.65 cum per 100 metres
and supplying and planting hedge plants at 30 cm apart complete as per m 60.00
specification. A) Planting permanent hedges including digging of trenches.
MORT & H Specification No. 307 (PWD SR2009-10/P.No.135/19.84)

19.85 KSRRB -300-7.1 : Planting permanent hedges including diggid of


trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed
with farmyard manure, supplied at the rate of 4.65 cum per 100 metres
and supplying and planting hedge plants at 30 cm apart complete as per m 85.00
specification. A) Maintenance of hedge for one year. MORT & H
Specification No. 307 (PWD SR2009-10/P.No.135/19.84)

KSRRB M300-Planting and Maintaining of Flowering Plants and


Shrubs
19.86 KSRRB -300-8.1: Planting and Maintaining of Flowering Plants and
Shrubs- A) Planting flowering plants and shrubs in central verge . MORTH m 19.00
Specification No. 307 (PWD SR2009-10/P.No.135/19-86)

19.87 KSRRB -300-8.2: Planting and Maintaining of Flowering Plants and


Shrubs- A) Maintenance of flowering plants and shrubs in central verge fo
rone year.. MORTH Specification No. 307 (PWD SR2009- Km 88450.00
10/P.No.135/19.87)

KSRRB M300- Planting of trees and their maintenance for one year

19.88 KSRRB -300-9 : Planting of trees by the road side (Avenue trees )in 0.60
m dia holes, 1 m deep dug in the ground, mixing the soil with decayed
farm yard/sludge manure, planting the saplings, backfilling the trench,
watering, fixing, the tree guard and maintaining the plants for one year Each 440.00
complete as per specifications. MORT & H Specification No. 307(PWD
SR2009-10/P.No.136/19.88)

KSRRB M300- Renovation lawns including, weeding, forking the


ground, top dressing with forked soil.
19.89 KSRRB -300-10 :Renovation lawns including, weeding, forking the ground,
top dressing with forked soil, watering and maintenance the lawns for 30
days or more, till the grass forms a thick lawn, free from weeds, and fit for
moving and disposal of rubbish as directed, including supplying good Sqm 7.00
earth, if needed but excluding the cost of well decayed farmyard nature.
complete as per specifications. MORTH Specification No. 308 (PWD
SR2009-10/P.No.136/19.89)

KSRRB M300-Supply at site of work well decayed farm yard manure.

19.90 KSRRB -300-11 : Supply at site of work well decayed farm yard manure
from any available source, approved by the engineers incharge including
screening and stackin complete as per specifications. MORT & H Cum 180.00
Specification No. 308.2(PWD SR2009-10/P.No.136/19.90)

KSRRB M300-Supply at site of work / store-deoiled neem cake.


19.91 KSRRB -300-11 : Supply at site of work / store-deoiled neem cake duly
pakced in used gunny bags complete as per specifications. MORT & H q 1080.00
Specification No. 308.2(PWD SR2009-10/P.No.136/19.91)

KSRRB M300-Supply sludge.


19.92 KSRRB -300-12 : Supplying sludge duly stacked at site / store complte as
per specifications. MORT & H Specification No. 308.2(PWD SR2009- Cum 180.00
10/P.No.136/19.92)

KSRRB M300-Half brick circular tree guard.


19.93 KSRRB -300-13 : Half brick circular tree guard in 2nd cloths brick, internal
diametre 1.25 metres and hight 1.2 metres, above ground and 0.20 metre
below ground, bottom two courses lide dry, and top three courses in
cement morter 1:6 (1 cement 6 sand ) and intermediate courses being in Each 1210.00
dry honey comb masonry, as per design complete, complete as per
specifications. MORT & H Specification No. 308.2(PWD SR2009-
10/P.No.136/19.92)

KSRRB M300-Edging with 2nd class bricks, laid dry lengthwise


19.94 KSRRB -300-15 : Edging with 2nd class bricks, laid dry lengthwise
including excavation, refilling, consolidation, with a hand packing and
spreading nearly surplus within a lead of 50 metres, complete as per m 24.00
specifications. (PWD SR2009-10/P.No.136/19.94)

KSRRB M300-Making tree guard from empty bitumen drums


19.95 KSRRB -300-16: Making tree guard 53 cm dia and 1.3 m high as per
design from empty bitumin drum, slite suitably to permit sun and air,
( Supplyed by the Department at stock issue rate) including
Providing and fixing 2 Nos MS sheet rings 50x0.5 mm with rivers, Each 245.00
copmplete in all respect complete as per specifications. (PWD SR2009-
10/P.No.137/19.95)

19.96 KSRRB -300-17: Making tree guard 53 cm dia and 2 m high as per design
from empty bitumin drum, slite suitably to permit sun and air,
( Supplyed by the Department at stock issue rate) including Providing and
fixing four legs 40 cm long of 30x3 mm MS riveted to tree guard and Each 525.00
providing and fixing 2 Nos MS sheet rings 50x0.5 mm with rivers,
copmplete in all respect complete as per specifications. (PWD SR2009-
10/P.No.137/19.96)

KSRRB M300-Wrought Iron and mild steel welded work.


19.97 KSRRB -300-18: Wrought Iron and mild steel welded work. (Using angles,
square bars, tees and channel grills, grating frames, gates and tree guards
of any side and design etc.,includign cost of screens and welding rods or
bolts and nuts complete fixed in position but without the cost of excavation q 5610.00
and concrete for fixing which will be paid saperately complete as per
specifications. (PWD SR2009-10/P.No.137/19.97)

KSRRB M300-Tree gaurd with MS iron.


19.98 KSRRB -300-19: Providing and fixing MS iron free guard 60 cm dia and 2
metre high above ground level formed of 4 Nos (25 x 6 mm) and 8 Nos (25
mm X 3 mm ) vertical MS riveted to 3 Nos (25 X 6 mm ) iron rings in two
halves, bolted together with 8 mm dia and 30 mm long bolts including Each 1560.00
painting two coats woth paint of approved brand over a coat of priming,
complete in all respects, complete as per specifications. (PWD SR2009-
10/P.No.137/19.98)

KSRRB M300-Tree gaurd with MS Angle and Steel wire.


19.100 KSRRB -300-20: Providing and fixing tree guard 0.60 metre square, 2.00
metre high fabricated with MS angle iron 30 X 30 X 30 mm, MS iron 25 x 3
mm and steel wire 3 mm dia welded and fabricated as per design in two Each 2050.00
halves bolted together complete as per specifications. (PWD SR2009-
10/P.No.137/19.100)

KSRRB M300-Compensatory afforestation.


19.101 KSRRB -300-21: Planting trees as compensatory afforestaiton at the rate
of 290 trees per hectare at a spacing of 6 m by grubbing and leveling the
ground upto a depth of 150 mm, digging holes 0.9 m dia, 1 m deep, mixing Ha 51400.00
farm yard / sludge manure with soil, planting of saple. complete as per
specifications. (PWD SR2009-10/P.No.137/19.101)

SUB BASES - BASES (NON BITUMINOUS)


AND SHOULDERS

Sl. Description Rate


Unit
No. Rs. Ps.
KSRRB 400 - Granular Sub-base
20.1 KSRRB 400-1. Providing, laying, spreading and compacting inverted
choke of screening Type 'B' or sand in sub-base course in uniform layer on
a prepared base by mechanical means with motor grader and compacting
with power roller including cost of all materials, labour, HOM of Cum 970.00
machineries complete as per specifications -MORTH chapter 4 (PWD
SR2009-10/P.No.139/20.1)

20.2 KSRRB 400-2. Providing, laying, spreading and compacting specified


graded sand, gravel or any other course material in sub-base course
including premixing the material at OMC in mechanical mixer (Pug mill),
carriage of mixed material up to 1 km, spreading in uniform layers with
motor grader on a prepared base and compacting with power roller to Cum 1570.00
achieve the desired density including all materials, labour, HOM of
machinery, lighting, guarding, barricading and maintenance of diversion
complete as per specifications -MORTH chapter 4 (PWD SR2009-
10/P.No.139/20.2)
20.3 KSRRB 400-4. Providing, laying, spreading and compacting specified
graded sand, gravel or any other course material in sub-base course
including premixing the material at OMC in mechanical mixer (Pug mill),
carriage of mixed material up to 1 km, spreading in uniform layers with
motor grader on a prepared base and compacting with power roller to
achieve the desired density lighting, guarding, barricading and Cum 1580.00
maintenance of diversion, including cost of all materials, labour, HOM of
machinery, complete as per specifications (material and grinding shall be
as per design mix formula) -MORTH chapter 4 (PWD SR2009-
10/P.No.139/20.3)

20.4 KSRRB M400-6.1. Construction of granular sub-base by providing close


graded Material, mixing in a mechanical mix plant at OMC, carriage of
mixed Material to work site, spreading in uniform layers with motor grader
on prepared surface and compacting with vibratory power roller to achieve
the desired density, complete as per specifications. A. Plant Mix Method
using grit (PWD SR2009-10/P.No.139/20.4)

20.4.1 KSRRB M400-6.1. Construction of granular sub-base by providing close


graded Material, mixing in a mechanical mix plant at OMC, carriage of
mixed Material to work site, spreading in uniform layers with motor grader
on prepared surface and compacting with vibratory power roller to achieve Cum 1010.00
the desired density, For Grading I Material complete as per specifications.
(PWD SR2009-10/P.No.139/20.4.1)

20.4.2 Construction of granular sub-base by providing close graded Material,


mixing in a mechanical mix plant at OMC, carriage of mixed Material to
work site, spreading in uniform layers with motor grader on prepared
surface and compacting with vibratory power roller to achieve the desired Cum 1000.00
density, complete as per clause 401 of MORT & H For Grading - II Material
(225*1.28 = 288 cum) (PWD SR2009-10/P.No.139/20.4.2)

20.4.3 Construction of granular sub-base by providing close graded Material,


mixing in a mechanical mix plant at OMC, carriage of mixed Material to
work site, spreading in uniform layers with motor grader on prepared
surface and compacting with vibratory power roller to achieve the desired Cum 890.00
density, complete as per clause 401 of MORT & H For Grading - III
Material (PWD SR2009-10/P.No.139/20.4.3)

20.5 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density,
complete as per specifications. B. By Mix in Place Method using grit
(PWD SR2009-10/P.No.139/20.5)

20.5.1 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density, Cum 1030.00
complete as per specifications. Close graded granular sub-base material
as per 400-1 For grading I Material (PW SR2009-10/P.No.140/20.5.1)
20.5.2 KSRRB M400-6.2. Construction of granular sub-base by providing coarse
graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density, Cum 920.00
complete as per specifications. Close graded granular sub-base material
as per 400-1 For grading II Material (PW SR2009-10/P.No.140/20.5.2)

20.5.3 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density, Cum 800.00
complete as per specifications. Close graded granular sub-base material
as per 400-1 For grading III Material (PW SR2009-10/P.No.140/20.5.3)

KSRRB 400 Granular Sub-Base with Coarse Graded Material


(table 400-2)
20.6 KSRRB M400-7 Construction of granular sub-base by providing coarse
graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method with rotavator at OMC,
and compacting with vibratory roller to achieve the desired density,
complete as per specifications using grit. (PWD SR2009-
10/P.No.140/20.6)

20.6.1 KSRRB M400-7 Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method with rotavator at OMC,
and compacting with vibratory roller to achieve the desired density, Cum 1120.00
complete as per specifications using grit. For Coarse graded granular sub-
base material as per 400-2 For grading I Material (PWD SR2009-
10/P.No.140/20.6.1)

20.6.2 Construction of granular sub-base by providing coarse graded material,


spreading in uniform layers with motor grader on prepared surface, mixing
by mix in place method with rotavator at OMC, and compacting with
vibratory roller to achieve the desired density, complete as per clause 400- Cum 1050.00
2 of MORT & H For Grading - IIMaterial (PWD SR2009-
10/P.No.140/20.6.2)

20.6.3 Construction of granular sub-base by providing coarse graded material,


spreading in uniform layers with motor grader on prepared surface, mixing
by mix in place method with rotavator at OMC, and compacting with
vibratory roller to achieve the desired density, complete as per clause 400- Cum 925.00
2 of MORT & H For Grading - III Material (PWD SR2009-
10/P.No.140/20.6.3)

KSRRB M400-Lime stabilization for improving subgrade


20.7 KSRRB M400-8.1 Laying, and spreading available soil in the subgrade on
a prepared surface, pulverising, mixing the spread soil in place with
rotavator with 3 percent slaked lime having minimum content of 70 percent
of CaO, grading with motor graded and compacting with the road roller at
OMC to the desired density to form a layer of improved subgrade complete Cum 285.00
as per specifications. A. By Mechanical means. MORT & H. Specificaton
No.402. (PWD SR2009-10/P.No.140/20.7)
20.8 KSRRB M400-8.2 Lime Stabilisation for improving Subgrade Laying, and
spreading available soil in the subgrade on a prepared surface,
pulverising, mixing the spread soil in place with rotavator with 3 percent
slaked lime having minimum content of 70 percent of CaO, grading with
motor graded and compacting with the road roller at OMC to the desired Cum 275.00
density to form a layer of improved subgrade complete as per
specifications. B. By Manual means. MORT & H. Specificaton No.402.
(PWD SR2009-10/P.No.140/20.8)

KSRRB M400 - Lime Treated Soil for Sub-Base.


20.9 KSRRB M400-9 Providing, Laying, and spreading soil on a prepared
subgrade, pulverising, mixing the spread soil in place with rotavator with 3
percent slaked lime having minimum content of 70 percent of CaO,
grading with motor graded and compacting with the road roller at OMC to Cum 350.00
achieve atleast 90% of the maximum dry density to form a layer of sub-
base complete as per specifications. MORT & H. Specificaton No.402.
(PWD SR2009-10/P.No.140/20.9)

KSRRB M400 - Cement Treated Soil for Sub-Base/Base.


20.10 KSRRB M400-10 Providing, Laying, and spreading soil on a prepared
subgrade, pulverising, adding the designed quantity of cement to the
spread soil mixing in place with the rotavator grading with motor graded
and compacting with the road roller at OMC to achieve the desired
unconfined compressive strength and to form a layer of sub-base/base Cum 760.00
complete as per specifications.( For 4% quantity of cement by weight of
soil).,MORT & H. Specificaton No.403. (PWD SR2009-10/P.No.141/20.10)

KSRRB M400 - Cement Treated Crushed rock or Combination as per


Clause 403.2 & Table 400.4 in Sub-Base/Base.
20.11 KSRRB M400-11 Providing, Laying, and spreading material soil on a
prepared subgrade, adding the designed quantity of cement to the spread
material, mixing in place with the rotavator grading with motor graded and
compacting with the road roller at OMC to achieve the desired unconfined
compressive strength and to form a layer of sub-base/base complete as
per specifications.( quantity of cement assumed as 4% of quantity of
crushed rock by weight ).,MORT & H. Specificaton No.403. (PWD
SR2009-10/P.No.141/20.11)

20.11.1 KSRRB M400-11 Providing, Laying, and spreading material soil on a


prepared subgrade, adding the designed quantity of cement to the spread
material, mixing in place with the rotavator grading with motor graded and
compacting with the road roller at OMC to achieve the desired unconfined
compressive strength and to form a layer of sub-base/base complete as Cum 1760.00
per specifications.Cement at site at 4% by wt. of crushed aggregate
(600 tonne) Grading of material for Sub-base course.,MORT & H.
Specificaton No.403. (PWD SR2009-10/P.No.141/20.11.1)

20.11.2 KSRRB M400-11 Providing, Laying, and spreading material soil on a


prepared subgrade, adding the designed quantity of cement to the spread
material, mixing in place with the rotavator grading with motor graded and
compacting with the road roller at OMC to achieve the desired unconfined
compressive strength and to form a layer of sub-base/base complete as Cum 1390.00
per specifications.Cement at site at 4% by wt. of crushed aggregate
(600 tonne) Grading of material for base course.,MORT & H.
Specificaton No.403. (PWD SR2009-10/P.No.141/20.11.2)

KSRRB M400 - Making 50mm X 50mm Furrows


20.12 KSRRB M400 - Making 50mm X 50mm Furrows, 25mm deep, 450 to the
center line of the road and at one meter interval in the existing thin
bituminous wearing coarse including sweeping and disposal of excavated Sqm 1.80
material within 1000 metres lead Complete as per specifications. MORTH
specification No. 404.3.1

KSRRB M400-Inverted Choke


20.13 KSRRB M400-13. Construction of Inverted Choke by providing, laying,
spreading and compacting screening B type/coarse sand of specified
grade in uniform layer on a prepared surface with motor grade and Cum 990.00
compacting with power roller etc., Complete as per specifications. .
MORTH specification No. 404.3.2

KSRRB M400 - Water Bound Macadam


20.14 KSRRB M400-14.1. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and
compacting to the required density. complete as per specification.
A. By manual means. MORTH Specification No. 404. (PWD
SR2009-10/P.No.141/20.14)

20.14.1 KSRRB M400-14.1. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1440.00
compacting to the required density. complete as per specification.
Type A 13.2mm for grading II. MORTH Specification
No. 404. (PWD SR2009-10/P.No.142/20.14.1)

20.14.2 KSRRB M400-14.2. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1310.00
compacting to the required density. complete as per specification.
Crushable type such as Moorum or Gravel for
grading III. MORTH Specification No. 404. (PWD SR2009-
10/P.No.142/20.14.2)

20.14.3 KSRRB M400-9. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1580.00
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Scrining Type-B (11.2mm agg.) Grading-III (Manual) Clause : 404 of
MORT & H. (PWD SR2009-10/P.No.142/20.14.3)
20.14.4 Providing, laying, spreading and compacting stone aggregates of specific
sizes to water bound macadam specification including spreading in
uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory
roller 8-10 tonnes in stages to proper grade and camber, applying and
brooming requisite type of screening/binding Materials to fill up the
interestices of coarse aggregate, watering and compacting to the required Cum 1375.00
density. Material (Refer table 400 - 7, 8 & 9) Using Screening Crushable
type such as Moorum or Gravel for Grading - III (Manual) Clause : 404 of
MORT & H. (PWD SR2009-10/P.No.142/20.14.4)

20.15 KSRRB M400 - 14.2. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and
compacting to the required density. Complete as per specifications.
B.Mechanical means. MORT & H Specification No. 404. (PWD SR2009-
10/P.No.142/20.15)

20.15.1 Providing, laying, spreading and compacting stone aggregates of specific


sizes to water bound macadam specification including spreading in
uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory
roller 8-10 tonnes in stages to proper grade and camber, applying and
brooming requisite type of screening/binding Materials to fill up the Cum 1370.00
interestices of coarse aggregate, watering and compacting to the required
density. Material (Refer table 400 - 7, 8 & 9) Using Scrining Type-A
(13.2mm agg.) Grading - II (Mechanical) Clause : 404 of MORT & H.
(PWD SR2009-10/P.No.142/20.15)

20.15.2 KSRRB M400-14.2. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1250.00
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Screening Crushable type such as Moorum or Gravel Grading - III
(Mechanical) Clause : 404 of MORT & H. (PWD SR2009-
10/P.No.142/20.15.2)

20.15.3 KSRRB M-400.14.2. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding Cum 1510.00
Materials to fill up the interestices of coarse aggregate, watering and
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Scrining Type-B (11.2mm agg.) Grading - III (Mechanical) Clause :
404 of MORT & H. (PWD SR2009-10/P.No.142/20.15.3)
20.15.4 KSRRB M400-14.2. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1310.00
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Screening Crushable type such as Moorum or Gravel Grading - III
(Mechanical) Clause : 404 of MORT & H. (PWD SR2009-
10/P.No.142/20.15.2)

KSRRB M400-Crushed cement Sub-base/base.


20.16 KSRRB -400-15. Breaking and crushing of material obtained by breaking
damaged cement concrete slabs to size range not exceeding 75mm as
specified in Table 400.7 transporting the aggregate obtained from breaking
of cement concrete slabs, laying and compacting the same as sub-
base/base course, constructed as WBM to Clause 400.4 except the use of Cum 145.00
screening or binding material complete as per specifications. MORTH
Specification No. 405. (PWD SR2009-10/P.No.142/20.16)

KSRRB M400 - Penetration Coat over top layer of crushed cement


concrete base.

20.17 KSRRB -400-16 Spreading of bitumen over cleaned dry surface of crushed
cement concrete base at the rate of 25 kg per 10 sqm by a bitumen
pressure distributor, spreading of key aggregates at the rate of 0.13 cum
per 10 sqm by a mechanical gritter and rolling the surface as per clause Sqm 17.00
500.6.3.8 Complete as per specification. No.405.2 (PWD
SR2009-10/P.No. 142/20.17)

KSRRB M400 - Wet mix Macadam


20.18 KSRRB M400-17. Providing, laying, spreading and compacting graded
stones aggregates to wet mix macadam specification including pre mixing
the material with water at OMC in mechanica; mix plant carriage of mixed
method of tipper to site, laying in uniform layers with pavar in sub-
base/base course on well prepared surface and compacting with vibratory Cum 1130.00
roller to achieve the desired density complete as per specifications.
MORTH Specification No. 406. (PWD SR2009-10/P.No.142/20.18)

KSRRB M400-Construction of Median and Island with soil taken from


Roadway cutting.
20.19 KSRRB M400-18. Construction of Median and Island above road level with
approved material deposited at site from roadway cutting and excavation
for drain foundation of other structures, spread, graded and compacted as Cum 79.00
per clause 400.7 complete as per specifications. MORTH Specification
No. 406. (PWD SR2009-10/P.No.143/20.19)

KSRRB M400-Construction of Median and Island with soil taken from


Borrow Areas.
20.20 KSRRB M400-19. Construction of Median and Island with island with Soil
taken from Borrow Areas. Construction of Median and island above road
level with approved material deposited from borrowpits, spread, sloped Cum 98.00
and compacted as per Clause 400.7 complete as per specifications.
MORTH Specification No. 407. (PWD SR2009-10/P.No.143/20.20)

KSRRB M400-Construction of footpath and separator


20.21 KSRRB M400-.21.Construction of footpath /separator by providing a 150
mm compacted granular sub-base as per clause 401 & 25mm thick
cement concrete grade M-15, overlaid with precast concrete tiles in
cement mortar 1:3 including provision of all drainage arrangements but Sqm 535.00
excluding kerb channel complete as per specification.MORTH
Specification No. 409. (PWD SR2009-10/P.No.143/20.21)

KSRRB M400-22 Crusher Rum Macadam base


20.22 KSRRB M400-.22.1. Providing crushed stone aggregate, depositing on a
prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 1315.00
A. By mix in place method. (For 53 mm maximum
size) MORTH Specification No. 410. (PWD SR2009-10/P.No.143/20.22)

20.23 KSRRB M400-.22.1. Providing crushed stone aggregate, depositing on a


prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 1360.00
A. By mix in place method. (For 45 mm maximum
size) MORTH Specification No. 410. (PWD SR2009-10/P.No.143/20.23)

20.24 KSRRB M400-.22.2. Providing crushed stone aggregate, depositing on a


prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 1415.00
A. By mixing Plant method. (For 53 mm maximum
size) MORTH Specification No. 410. (PWD SR2009-10/P.No.143/20.24)

20.25 KSRRB M400-.22.2. Providing crushed stone aggregate, depositing on a


prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 1470.00
A. By mixing Plant method. (For 45 mm maximum
size) MORTH Specification No. 410. (PWD SR2009-10/P.No.143/20.25)

KSRRB M400- Lime. Flyash stabilised Soil Sub-base.


20.26 KSRRB M400-23. Lime. Flyash stabilised Soil Sub-base. Construction of
sub-base using lime-flyash admixture with granular soil, free from organic
matter/deleterious material or clayey silts and low plasticity clays having PI
between 5 & 20 and liquid limit less than 25 and commercial dry lime
slaked at site or pre-slaked with CaO content not less than 50 %, flyash to
conform to gradation as per Clause 43 of IRC: 88-1984, lime+flyash Cum 205.00
content ranging between 10 to 30%, the minimum un-confined
compressive strength and CBR value after 28 days curing and 4 days
soaking to be 705 kg/sqcm and 25% respectively, all as specified in
IRC:88-1984 complete as per specifications.

KSRRB 400- Base


20.27 KSRRB M400-24. Providing, laying, spreading and compacting stone
aggregate of specific sizes to water bound macadam specifications by
manual means, including spreading in uniform thickness, hand packing,
rolling with power roller 8-10 tonnes in stages to proper grade and camber,
applying and brooming requisite type of screening/binding materials to fill
up the interstices of coarse aggregates, watering and rolling, making Cum
necessary earthern bund to protect edges, lighting, guarding, barricading,
and maintenance of diversion, including cost of all materials, labour, HOM
of machinery, complete as per specifications. MORTH Chapter 4
20.28 KSRRB 400-25. Providing, laying, spreading and compacting stone
aggregate of specific sizes to water bound macadam specifications by
mechanical means, including spreading in uniform thickness, hand
packing, rolling with power roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
materials to fill up the interstices of coarse aggregates, watering and Cum
rolling, making necessary earthern bund to protect edges, lighting,
guarding, barricading, and maintenance of diversion, including cost of all
materials, labour, HOM of machinery, complete as per specifications.
MORTH Chapter 4

BASE AND SURFACE COURSES (BITUMINOUS)

Sl.No. Description
Unit Rate

KSRRB 500-1. Cleaning the existing surface.


21.1 KSRRB 500-1 : Cleaning the existing WBM road sufrace including
removing of binding materials and other foreign matter with wire brushes
and small picks, sweeping wih brooms or soft brushes and finally dusting
with old gunny bags and / or compressed air, to receive bituminous
treatment including cost of all materials, labour, HOM of machineries Sqm 7.00
complete as per specifications. MORT & H (PWD SR2009-10/P.No.
147/21.1)

21.2 KSRRB 500-.2 : Cleaning the existing black topped surface with brooms,
soft brushes and finally dusting with old gunny bags and / or compressed
air to receive bituminous treatment including cost all materials, labour, Sqm 1.70
HOM of machineries complete as per specifications. MORT & H (PWD
SR2009-10/P.No. 147/21.2)

21.3 KSRRB 500-3 : Scarifying existing stone metal layer upto 75mm thick
along with their bituminous surface, picking up scarified materials and
stacking of old serviceable materilas with lead of 100 m. sequential
spreading of the salvaged aggregates with fresh aggregates on prepared
base and consolidatig as per water bound macadam specifications Sqm 58.00
including cost all materials, labour, HOM of machineries complete as per
specifications. MORT & H (PWD SR2009-10/P.No. 147/21.3)

KSRRB 500-Applying primer coat over prepared surface


21.4 KSRRB 500-4. Providing and applying primer coat from 7.5 to 9.8 kg and
9.8 to 12.2 kg per 10 sqm for surfaces of low and medium porosity
respectively over prepared surface of granular base with cut back M.C-70
or any other bitumen mixed with diesel at 10kg per 10 sqm heated in Sqm 50.00
bitumen boiler fitted with spray set (excluding cleaning of road surface)
including cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH (PWD SR2009-10/P.No.147/21.4)

21.5 KSRRB 500-5. Providing and applying primer coat from 12.2 to14.6kg per
10 sqm for surfaces of high porosity over prepared surface of granular
base with cut back M.C-70 or any other bitumen mixed with diesel at 13kg
per 10 sqm heated in bitumen boiler fitted with spray set (excluding Sqm 71.00
cleaning of road surface) including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTH (PWD SR2009-
10/P.No.147/21.5)

KSRRB 500-Primer coat/Tack coat


21.6 KSRRB M500-6. Providing and applying primer coat with bitumen
emulsion on prepared surface of granular Base including clearing of road
surface and spraying primer at the rate of 0.60 kg/sqm using mechanical Sqm 20.00
means. Complete as per specifications MORTH Specification No. 502
(PWD SR2009-10/P.No.147/21.6)

21.7 KSRRB M500-8. Providing and applying tack coat on the prepared black
topped surface at 7.5 kg per 10 sqm, heating bitumen in boiler fitted with
spray set (excluding cleaning of road surface) including cost of all Sqm 17.00
materials labour, HOM of machineriesComplete as per specifications
MORTH (PWD SR2009-10/P.No.148/21.7)

21.8 KSRRB M500-8. Providing and applying tack coat on granular surface
treated with primer at 7.5 kg per 10 sqm, heating bitumen in boiler fitted
with spray set (excluding cleaning of road surface) including cost of all Sqm 26.00
materials labour, HOM of machineriesComplete as per specifications
MORTH (PWD SR2009-10/P.No.148/21.8)

21.9 KSRRB M500-9. Providing and applying tack coat on granular base such
as WBM and WMM surfaces hot bitumen prined at 10 kg per 10 sqm,
heating bitumen in boiler fitted with spray set (excluding cleaning of road
surface) including cost of all materials labour, HOM of Sqm 34.00
machineriesComplete as per specifications MORTH (PWD SR2009-
10/P.No.148/21.9)

21.10 KSRRB M500-10 : Tack coat:- Providing and applying Tack coat with
bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg
per sqm on the prepared bituminous/granular surface cleaned with Sqm 7.50
mechanical broom. complete As per Specification MORTH specification
No. 503. (PWD SR2009-10/P.No.148/21.10)

KSRRB 500-Bituminous macadam


21.11 KSRRB M500-11: Providing and laying bituminous macadam on prepared
surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E.loader, hot
mixing of stone aggregates and bitumen in hot mix plant 40-60 tonne
capacity, transporting the mixed material in tipper tp paver and laying
mixed materials with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density,
50/75 mm compacted thickness with 3.3% bitumen but excluding cost of
primer/tack coat with lead upto 1 km including cost of all materials, labour,
HOM of machineries complete as per specifications.
MORTH Specification No. 504.
(Bitumen=0.072 ton/cum metal=1.415) (PWD SR2009-10 /P.No.148/
21.11)

21.11.1 KSRRB M500-11: Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E.loader, hot
mixing of stone aggregates and bitumen in hot mix plant 40-60 tonne
capacity, transporting the mixed material in tipper tp paver and laying
mixed materials with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density, Cum 4440.00
80/100 mm compacted thickness with 3.3% bitumen but excluding cost of
primer/tack coat with lead upto 1 km including cost of all materials, labour,
HOM of machineries complete as per specifications.
MORTH Specification No. 504.
(Bitumen=0.072 ton/cum metal=1.415) (PWD SR2009-10 /P.No.148/
21.11)
21.11.2 KSRRB M500-11: Providing and laying bituminous macadam on prepared
surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E.loader, hot
mixing of stone aggregates and bitumen in hot mix plant 40-60 tonne
capacity, transporting the mixed material in tipper tp paver and laying
mixed materials with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density, Cum 4530.00
60/70 mm compacted thickness with 3.3% bitumen but excluding cost of
primer/tack coat with lead upto 1 km including cost of all materials, labour,
HOM of machineries complete as per specifications.
MORTH Specification No. 504.
(Bitumen=0.072 ton/cum metal=1.415) (PWD SR2009-10 /P.No.148/
21.11.2)

21.12 KSRRB 500-12. Providing, laying and consolidating of crushed stone


aggregates on prepared surface as per built up spray grout specifications
75mm thick, as base course complete in two layers composite constructon
of crushed stone aggregates with application of bitumen binder after each
layer and lay aggregate on the top of second layer and rolling with power
roller 8 to 10 tonne but excluding cost of primer / tack coat including cost Sqm 250.00
of all materials, labour, HOM of machineries complete as per
specifications. MORTH Chapter 5 with 80/100 grade bitumen
(Bitumen=0.003 ton metal=0.113) (PWD SR2009-10 /P.No.148/ 21.12)

21.13 KSRRB 500-13. Providing, laying bituminous macadam 50mm thick with
100-120 TPH hot mix plant producing an average output of 75 tonnes per
hour using crushed aggregates of specified grading premixed with
bituminous binder, transported to site, laid over a previously prepared
surface with paver finisher hydrostatic with sensor control to the required Cum 4440.00
grade, level and alignment and rolled as per Clauses 501.6 and 501.7 to
achieve the desired compaction complete as per sepcifications using
80/100 grade bitumen MORTH Specification No. 504 (PWD SR2009-
10 /P.No.149/ 21.13)

KSRRB M500- Bituminous Penetration macadam


21.14 KSRRB M500-14.1. Construction of penetration macadam over prepared
base by Providing and layer of compacted crushed coarse aggregate
using chips spreader with alternate applications of bituminious binder and
key aggregates and rolling with a vibratory roller 8-10 tonne capacity to Sqm 245.00
achieve the desired degree of compaction. complete as per specifications.
A. 50mm thick. MORTH Specification No. 505 (PWD SR2009-
10/P.No.149/20.14)

21.15 KSRRB M500-14.1. Construction of penetration macadam over prepared


base by Providing and layer of compacted crushed coarse aggregate
using chips spreader with alternate applications of bituminious binder and
key aggregates and rolling with a vibratory roller 8-10 tonne capacity to Sqm 325.00
achieve the desired degree of compaction. complete as per specifications.
A. 75mm thick. MORTH Specification No. 505 (PWD SR2009-
10/P.No.149/20.15)

KSRRB 500-Built up Spray Grout


21.16 KSRRB M500-15. Providing, laying and rolling with vibratory roller of built-
up spray grout layer over prepared base consisting of a two layer
composite construction of compacted crushed coarse aggregates using
motor grader for aggregates. Key stone chips spreader may be used with
application of bituminious binder after each layer, and with key aggregates
placed on top of the second layer to serve as a base conforming to the
line, grades and cross-section specified, the compacted layer thickness Sqm 219.00
being 75 mm complete as per specifications. MORTH Specification No.
506 with 80/100 grade bitumen (Bitumen=0.003 metal=0.113) (PWD
SR2009-10/P.No.149/21.16)

KSRRB 500-Dense bituminous macadam


21.17 KSRRB M500-16. Providing, laying dense bituminous macadam 40mm
compcated thickness with 5% bitumen 80/100 grade, contents on prepared
surface with specified graded crushed aggregates for base/binder course
including loading of material with F.E. loader, heating of binder aggregates
and filler in hot mix plant 40-60 TPH, transporting the mixed material by
tipper and laying with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density (but Cum 6400.00
excluding primer / tack coat ) to a lead upto 1km including cost of all
materials, labour, HOM of machineries complete as per specifications.
( Bitumen=0.115 Metal=1.528) MORTH (PWD SR2009-
10/P.No.149/20.17)

21.18 KSRRB M500-17. Providing and laying dense graded bituminous


macadam with 100-125 TPH batch type HMP producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.0 to 4.5 percent by weight
of total mix and filler, transporting the hot mix to work site, laying with a
hydrostatic paver finisher with sensor control to the required grade, level
and alignment, rolling with smooth wheeled, vibratory and tandem rollers Cum 5380.00
to achieve the desired compaction as per MORTH specification clause No.
507 complete in all respects as per specifications, bitumen 80/100
(Bitumen = 0.0981 Metal = 1.44) MORTH Specification No. 507. (PWD
SR2009-10/P.No.149-150/20.18)

21.19 KSRRB M500-17. Providing and laying dense graded bituminous


macadam with 100-125 TPH batch type HMP producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.0 to 4.5 percent by weight
of total mix and filler, transporting the hot mix to work site, laying with a
hydrostatic paver finisher with sensor control to the required grade, level
and alignment, rolling with smooth wheeled, vibratory and tandem rollers Cum 5500.00
to achieve the desired compaction as per MORTH specification clause No.
507 complete in all respects as per specifications, bitumen 60/70
(Bitumen = 0.0981 Metal = 1.44) MORTH Specification No. 507. (PWD
SR2009-10/P.No.150/20.19)

KSRRB M500-Semi dense bituminous concrete


21.20 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.50 to 5.00 percent of mix
and filler, transporting the hot mix to work site, laying with a hydrostatic
paver finisher with sensor controll to the required grade,level and
alignment, rolling and smooth wheeled, vibratory and tandem rollers to
acheive the desired compaction as per MORTH Specification clause
No.500.8 complete in all respects. as per specifications (Bitumen = 0.104
Metal = 1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20)
21.20.1 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5575.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20.1) (80/100
grade bitumen )

21.20.2 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
Cum 5700.00
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20.3) (60/70
grade bitumen )

21.20.3 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5440.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20.3) (80/100
grade bitumen using 40-60 HMP)

21.20.4 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5560.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20.4) (60/70
grade bitumen using 40-60 HMP)

21.20.5 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5400.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20.5) (80/100
grade bitumen using 40-60 HMP & Mechanical Paver)
21.20.6 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5520.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2009-10/P.No.150/21.20.6) (60/70
grade bitumen using 40-60 HMP & Mechanical Paver)

21.21 KSRRB M500-18. Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.50 to 5.00 percent of mix
and filler, transporting the hot mix to work site, laying with a hydrostatic
paver finisher with sensor controll to the required grade,level and
alignment, rolling and smooth wheeled, vibratory and tandem rollers to
acheive the desired compaction as per MORTH Specification clause No.
508 complete in all respects as per specifications (PWD SR2009-
10/P.No.150/21.21)

21.21.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.50 to 5.00 percent of mix
and filler, transporting the hot mix to work site, laying with a hydrostatic
paver finisher with sensor controll to the required grade,level and Cum 6010.00
alignment, rolling and smooth wheeled, vibratory and tandem rollers to
acheive the desired compaction as per MORTH Specification clause No.
508 complete in all respects as per specifications (PWD SR2009-
10/P.No.150/21.21) with CRMB/POLYMER MB 70

21.21.2 KSRRB M500-18. Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.50 to 5.00 percent of mix
and filler, transporting the hot mix to work site, laying with a hydrostatic
paver finisher with sensor controll to the required grade,level and
alignment, rolling and smooth wheeled, vibratory and tandem rollers to Cum 6000.00
acheive the desired compaction as per MORTH Specification clause No.
508 complete in all respects as per specifications (PWD SR2009-
10/P.No.150/21.21) with NRMB 70 (LATEX OR RUBBER POWDER)

KSRRB M500-Bituminious Concrete


21.22 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.150-151/21.22)
21.22.1 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 6030.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.151/21.22) with Bitumen 80/100

21.22.2 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 6175.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.151/21.22) with Bitumen 60/70

21.22.3 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5900.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.151/20.22) with 80/100 grade Bitumen using 40-60 HMP

21.22.4 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 6040.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.151/21.22) with 60/70 grade Bitumen using 40-60 HMP
21.23 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. (PWD SR2009-
10/P.No.151/21.23)

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment, Cum 6525.00
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. (PWD SR2009-
10/P.No.151/21.23.1) With CRMB / POLYMER MB 70

21.23.2 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 6515.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. (PWD SR2009-
10/P.No.151/21.23.2) With NRMB 70 (LATEX OR RUBBER POWDER)

KSRRB 500-Extra for protecting the crushed stone chipping


21.24 KSRRB 500-21.1. Extra for labour for protecting the crushed stone
chipping with bitumen including heating and mixing the materials by
manual means and handling the mixed materials within a lead of 30 m.
Cum 460.00
including cost of all labour, HOM of machineries complete as per
specifications. MORTH Chapter 5 (PWD SR2009-10/P.No.151/21.24)

21.25 KSRRB 500-21.2. Extra for labour for protecting the crushed stone
chipping with bitumen including heating and mixing the materials by
mechanical means and handling the mixed materials within a lead of 30 Cum 560.00
m. including cost of all labour, HOM of machineries complete as per
specifications. MORTH Chapter 5 (PWD SR2009-10/P.No.151/21.25)

KSRRB 500-Surface dressing


21.26 KSRRB 500-22. Providing and laying single coat surface dressing or first
coat of the two surface dressing with 0.15 cum crushed stone chippings
and bitumen 18 kg / 10 sqm as wearing course consisting of a layer of
bituminious binder laid on the prepared surface followed by cover of
crushed stone chippings of specified size (may be pre-coated also) and Sqm 82.00
materials, labour, HOM of machineries complete as per specifications,
MORTH Chapter 5 (PWD SR2009-10/P.No.151/21.26)
21.27 KSRRB 500-23. Providing and laying second coat surface dressing (also
used as renewal one coat ) with 0.10 cum crushed layer as wearing
courseand bitumen 11 kg / 10 sqm as wearing course consisting of a layer
of bituminious binder laid on the prepared surface and rolling with power Sqm 54.00
roller 8-10 tonne capacity including cost of all materials, labour, HOM of
machineries complete as per specifications, MORTH Chapter 5 (PWD
SR2009-10/P.No.152/21.27)

21.28 KSRRB M500-24.1. Providing and laying surface dressing as wearing


course in single coat using crushed stone aggregates of specified size on
a layer of bituminious binder laid on prepared surface and rolling with 8-10
tonne smooth wheeled steel roller complete as per specifications. Case-I :- Sqm 58.00
19mm nominal chipping size MORTH Specifiacation No. 510 (PWD
SR2009-10/P.No.152/21.28)

21.29 KSRRB M500-24.2. Providing and laying surface dressing as wearing


course in single coat using crushed stone aggregates of specified size on
a layer of bituminious binder laid on prepared surface and rolling with 8-10
tonne smooth wheeled steel roller complete as per specifications. Case- Sqm 46.00
II :- 13mm nominal size chipping (Bitumen= 1kg/Sqm Metal=0.01)
MORTH Specifiacation No. 510 (PWD SR2009-10/P.No.152/21.29)

KSRRB 500-Open Graded premix carpet


21.30 KSRRB M500-25. Providing and laying open graded premix carpet using
bitumen and with specified graded crushed aggregates of 13.2mm to
5.6mm size for wearing course including loading of aggregates with F.E,
loader , heating binder and aggregates in hotmix plant 30 to 40 tonne,
transporting the mixed materials in tipper to a distance upto 1 km and
laying with paver finisher mechanical with capacity to required level and Sqm 87.00
grade, rolling with power roller 8-10 tonne excluding cost of tack and seal
coat including cost of all materials, labour, HOM of machineries complete
as per specifications. MORTH Chapter 5 (PWD SR2009-
10/P.No.152/21.30)

21.31 KSRRB M500-25. Providing and laying open graded premix carpet using
crumb rubber modified bitumen (CRMB 55) and with specified graded
crushed aggregates of 13.2mm to 5.6mm size for wearing course including
loading of aggregates with F.E, loader , heating binder and aggregates in
hotmix plant 30 to 40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km and laying with paver finisher mechanical with capacity Sqm 93.00
to required level and grade, rolling with power roller 8-10 tonne excluding
cost of tack and seal coat including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTH Chapter 5 (PWD
SR2009-10/P.No.152/21.30)

21.32 KSRRB M500-27. Providing and laying open graded premix carpet of
20mm thick on prepared surface as wearing course composed of 13.2 mm
to 5.6 mm size stone aggregates premixed with bituminous binder in mini
hot mix plant 6-10 tonne exclduing cost of primer / tack coat including cost Sqm
of all materials, labour, HOM of machineries complete as per
specifications.80/100 Bitumen (Bitumen=1.46 kg/Sqmt Metal= 0.027)
MORTH Chapter 5 (PWD SR2009-10/P.No.152/21.32)
21.32.1 KSRRB M500-27. Providing and laying open graded premix carpet of
20mm thick on prepared surface as wearing course composed of 13.2 mm
to 5.6 mm size stone aggregates premixed with bituminous binder in mini
hot mix plant 6-10 tonne exclduing cost of primer / tack coat including cost
of all materials, labour, HOM of machineries complete as per Sqm 90.00
specifications.80/100 Bitumen (Bitumen=1.46 kg/Sqmt Metal= 0.027)
MORTH Chapter 5 (PWD SR2009-10/P.No.152/21.32) Using 6-10 tonne
mini mix plant

21.33 KSRRB M500-28. Providing and laying open graded premix carpet of
20mm thick on prepared surface as wearing course composed of 13.2 mm
to 5.6 mm size stone aggregates premixed with bituminous binder in mini
hot mix plant 6-10 tonne exclduing cost of primer / tack coat including cost
of all materials, labour, HOM of machineries complete as per Sqm 99.00
specifications.80/100 Bitumen (Bitumen=1.46 kg/Sqmt Metal= 0.027)
MORTH Chapter 5 (PWD SR2009-10/P.No.152/21.33) Using CRMB

21.34 KSRRB M500-29.1. Providing laying and rolling of open graded premix
surfacing of 20mm thickness composed of 13.2 mm to 5.6 mm aggregates
either using penetration grade bitumen or cut-back or emulshion to
required line, grade and level to serve as wearing course on a previously
prepared base, including mixing in a HMP 100 TPH plant, laying and
rolling with a smooth wheeled roller 8-10 tonne capacity, finished to Sqm 84.00
required level and grades complete as per specifications.Case-1:
Mechanical method using penetration grade bitumen and HMP of
appropriate capacity not less than 75 tonne/hour" MORTH Specification
No.511 (PWD SR2009-10/P.No.152-153/21.34)

21.35 KSRRB M500-29.2. Providing laying and rolling of open graded premix
surfacing of 20mm thickness composed of 13.2 mm to 5.6 mm aggregates
either using penetration grade bitumen or cut-back or emulshion to
required line, grade and level to serve as wearing course on a previously
prepared base, including mixing in a HMP 100 TPH plant, laying and
rolling with a smooth wheeled roller 8-10 tonne capacity, finished to Sqm 102.00
required level and grades complete as per specifications.Case-II: Open
graded Pre mix Surfacing using cationic bitumen emulshion. MORTH
Specification No.511 (PWD SR2009-10/P.No.153/21.35)

KSRRB 500-30 Mix seal surface


21.36 KSRRB M500-30. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface as wearing course with specified graded crushed
aggregates of 11.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 20-30 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher 30-40 tonne capacity to Sqm 109.00
required level and grade, rolling with power roller 8-10 tonne excluding
cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications.MORTH Chapter 5 (PWD
SR2009-10/P.No153/21.35)

21.37 KSRRB M500-31. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface as wearing course with specified graded crushed
aggregates of 11.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 20-30 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher 30-40 tonne capacity to
required level and grade, rolling with power roller 8-10 tonne excluding Sqm 119.00
cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications.MORTH Chapter 5 (PWD
SR2009-10/P.No.153/21.37) with crumb rubber modified bitumen (CRMB
55) Morth Chapter 5
21.38 KSRRB M500-32. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface as wearing course with specified graded crushed
aggregates of 13.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 30-40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher to required level and Sqm 101.00
grade, rolling with power roller 8-10 tonne excluding cost of tack coat
including cost of all materials, labour, HOM of machineries complete as
per specifications.MORTH Chapter 5 (PWD SR2009-10/P.No.153/21.38)

21.39 KSRRB M500-33. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface as wearing course with specified graded crushed
aggregates of 13.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 30-40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher to required level and
grade, rolling with power roller 8-10 tonne excluding cost of tack coat Sqm 109.00
including cost of all materials, labour, HOM of machineries complete as
per specifications.MORTH Chapter 5 (PWD SR2009-10/P.No.153/21.39)
with crumb rubber modified bitumen binder Morth Chapter 5

21.40 KSRRB M500-34. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface in a single course composed of specified graded
crushed aggregates of 11.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8-
Sqm 113.00
10 excluding cost of primer/ tack coat including cost of all materials,
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2009-10/P.No.153/21.40)

21.41 KSRRB M500-35. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface in a single course composed of specified graded
crushed aggregates of 11.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8-
10 excluding cost of primer/ tack coat including cost of all materials, Sqm 122.00
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2009-10/P.No.153/21.41) with crumb rubber modified
bitumen (CRMB55) MORTH Chapter 5

21.42 KSRRB M500-36. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface in a single course composed of specified graded
crushed aggregates of 13.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8- Sqm 111.00
10 excluding cost of primer/ tack coat including cost of all materials,
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2009-10/P.No.154/21.42)

21.43 KSRRB M500-37. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface in a single course composed of specified graded
crushed aggregates of 13.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8- Sqm 112.00
10 excluding cost of primer/ tack coat including cost of all materials,
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2009-10/P.No.154/21.43) with crumb rubber modified
bitumen (CRMB 55)

KSRRB M500-Close-graded premix surfacing / Mixed Seal surfacing


21.44 KSRRB M500-38.1. Providing, laying and rolling of Close-graded premix
surfacing material of 20 mm thickness composed of 13.2 mm to 0.09 mm
(Type-B) aggregates using penetration grade bitumen 80/100 to the
required line, grade and level to serve as wearing course on a previously
prepared base, including mixing in a 40-60 TPH HMP plant, laying with Sqm 95.00
Paver finisher mechanical 100 T cappacity and rolling with a Smooth
wheeled roller as per specifications. (Bitumen+1.90 Kg/Sqm Metal=0.027)
MORTH Specification No. 512. (PWD SR2009-10/P.No.154/21.44)

KSRRB M500-Seal coat


21.45 KSRRB M500-39.1. Providing and laying a seal coat sealing the voids in
bituminious surface lay to the specified levels, grade 80/100 and cross fall
using Type'A' and B seal coats, Complete as per specifications using low
grade bitumen. (PWD SR2009-10/P.No.154/21.45)

21.45.1 KSRRB M500-39.1. Providing and laying a seal coat sealing the voids in
bituminious surface lay to the specified levels, grade 80/100 and cross fall
using Type'A' and B seal coats, Complete as per specifications using low Sqm 42.00
grade bitumen. Case: I. Type A (Bitumen 0.98 kg/Sqm Metal=0.009)
MORTH Specifications No. 513 (PWD SR2009-10/P.No.154/21.45.1)

21.45.2 KSRRB M500-39.1. Providing and laying a seal coat sealing the voids in
bituminious surface lay to the specified levels, grade 80/100 and cross fall
using Type'A' and B seal coats, Complete as per specifications using low Sqm 32.00
grade bitumen. Case: I. Type B (Bitumen 0.68 kg/Sqm Metal=0.009)
(PWD SR2009-10/P.No.154/21.45.2)

21.46 KSRRB M500-39.2. Providing and laying of premix sand seal coat with
HMP of appropriate capacity not less than 75 tonnes/hours using crushed
stone chipping 6.7 mm size and pentration bitumen of suitable grade Sqm 32.00
complete as per specifications. Case: II Type B
MORTH Specification No. 513. (PWD SR2009-10/P.No.154/21.45.2)

KSRRB M500-Mastic asphalt


21.47 KSRRB M500-41. Providing and laying 25 mm thick mastic asphalt
wearing course with paving grade bitumen the requirements given in table
500-29, prepared by using mastic cooker and laid to required level and
slope after cleaning the surface, including providing antiskid surface with
bitumen precoated fine grained hard stone chipping of 13.2 mm nominal
size at the rate of 0.005 cum per 10 sqm and at an approximate spacing of
Sqm 350.00
10 cm center to center in both directions, pressed insto surface when the
temperature of surfaces is not less than 100'C, producing 1 mm to 4 mm
over mastic surface, complete as per clause 500.15 as per specifications.
(PWD SR2009-10/P.No.154/21.47) Morth Specification No. 515

KSRRB M500-Recycling of bituminous pavement with Central


recycling plant
21.52 KSRRB M500-47. Recycling pavement by cold milling of exisitng
bituminious layers. Planning the surface after cold milling, reclaiming
excavated material to the extent of 30 percent of the required quantity,
hauling and stock pilling the reclaimed material near the central recycling
plant after carrying out necessary checks and evaluation, adding fresh
material including rejuvenators as required, mixing in a hot mix plant, Cum 4320.00
transporting and laying at site and compacting to the required grade, level
and thickness, as specfied in clause 500.17 complete as per
specifications. MORTH Specification No. 517. (PWD SR2009-
10/P.No.155/21.52)
KSRRB M500-Frog Spray
21.53 KSRRB M500-48. Providing and applying low viscosity bitumen emulsion
for sealing cracks less than 3 mm wide or incipient fretting or
disintegration in an existing bituminous surfacing complete as per Sqm 24.00
specifications. MORTH Specifiction No. 518 (PWD SR2009-
10/P.No.155/21.53)

21.54 KSRRB M500-48. Providing and applying low viscosity bitumen emulsion
for sealing cracks less than 3 mm wide or incipient fretting or
disintegration in an existing bituminous surfacing complete as per Sqm 3.80
specifications. (PWD SR2009-10/P.No.155/21.54)

KSRRB M500-Bituminous Cold mix (Including Gravel emulshion


21.55 KSRRB M500-49.1. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 7410.00
grades and levels complete as per specifications. Case-I: Using bitumen
emulshion & 9.5 mm or 13.2 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2009-10/P.No.155/21.55)

21.56 KSRRB M500-49.2. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 7400.00
grades and levels complete as per specifications. Case-II: Using bitumen
emulshion &19 mm or 26.5 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2009-10/P.No.155/21.56)

21.57 KSRRB M500-49.3. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 7300.00
grades and levels complete as per specifications. Case-III: Using cutback
bitumen &9.5 mm or 13.2 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2009-10/P.No.155/21.57)

21.58 KSRRB M500-49.4. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 7280.00
grades and levels complete as per specifications. Case-IV: Using cutback
bitumen & 19 mm or 26.5 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2009-10/P.No.155/21.58)

KSRRB M500-Sand-asphalt base course


21.59 KSRRB M500-50. Providing, laying and rolling sand-asphalt base course
composed of sand, mineral filler and bituminous binder on a preparedsub-
grade or sub-base to the lines, levels, grades and cross sections as per
the drawings including mixing in a plant of suitable type and capacity, Cum 5370.00
transporting, laying, compacting and finishing complete as per
specifications. MORTH Specifiction No. 520 (PWD SR2009-
10/P.No.156/21.59)

KSRRB 500-Liquid seal coat


21.60 KSRRB 500-52, Providing and applying Liquid seal coat Type 'A',
comprising of a layer of bituminous binder using bitumen followed by a
cover of stone chipping of 6.7 mm size and rolling with power roller 8-10
tonne including cost of all materials, labour, HOM of machineries complete Sqm 47.00
as per specifications using 80/100 Bitumen 0.98 kg/sqm Metal = 0.009)
MORTH Chapter 5.(PWD SR2009-10/P.No.156/21.60)

21.61 KSRRB 500-53, Providing and applying Liquid seal coat Type 'A',
comprising of a layer of bituminous binder using bitumen followed by a
cover of stone chipping of 6.7 mm size and rolling with power roller 8-10
tonne including cost of all materials, labour, HOM of machineries complete Sqm 51.00
as per specifications using 80/100 Bitumen 0.98 kg/sqm Metal = 0.009)
MORTH Chapter 5.(PWD SR2009-10/P.No.156/21.61)Using crumb rubber
modified bitumen (CRMB 55)

21.62 KSRRB 500-54. Providing and applying premix seal coat Type 'B'
comprising of thin application of fine aggregates passing 2.36 mm and
retained on 180 micron premixed with layer of bitumen binder using mini
hot mix plant carrying manually mixed materials, laying, rolling with power
roller 8-10 tonne including cost of all materials, labour, HOM of Sqm 32.00
machineries complete as per specifications. using 80/100 Bitumen
(Bitumen 0.68 Kg/sqm sand/Fine aggregate=0.06 cum) (PWD SR2009-
10/P.No.156/21.62)MORTH Chapter 5.

21.63 KSRRB 500-55. Providing and applying premix seal coat Type 'B'
comprising of thin application of fine aggregates passing 2.36 mm and
retained on 180 micron premixed with layer of bitumen binder using mini
hot mix plant carrying manually mixed materials, laying, rolling with power
roller 8-10 tonne including cost of all materials, labour, HOM of
Sqm 35.00
machineries complete as per specifications. using 80/100 Bitumen
(Bitumen 0.68 Kg/sqm sand/Fine aggregate=0.06 cum) MORTH Chapter
5. Using crumb rubber modified bitumen (CRMB 55)(PWD SR2009-
10/P.No.156/21.63)

KSRRB M500-Slurry seal


21.64 KSRRB M500-56.1. Providing and laying Slurry seal consisting of a
mixture of fine aggregates, portland cement filler, bituminous emulshion
and water on a road surface including cleaning of surface, mixing of slurry
seal in a suitable mobile plant, laying and compacting to provide even Sqm 46.00
riding surface Complete as per specifications. Case-I: 5 mm thickness
MORTH Specification No.516 (PWD SR2009-10/P.No.156/21.64)

21.65 KSRRB M500-56.2. Providing and laying Slurry seal consisting of a


mixture of fine aggregates, portland cement filler, bituminous emulshion
and water on a road surface including cleaning of surface, mixing of slurry
seal in a suitable mobile plant, laying and compacting to provide even Sqm 32.00
riding surface Complete as per specifications. Case-I: 3 mm thickness
MORTH Specification No.516 (PWD SR2009-10/P.No.156/21.65)

21.66 KSRRB M500-56.3. Providing and laying Slurry seal consisting of a


mixture of fine aggregates, portland cement filler, bituminous emulshion
and water on a road surface including cleaning of surface, mixing of slurry
seal in a suitable mobile plant, laying and compacting to provide even Sqm 19.00
riding surface Complete as per specifications. Case-III: 1.5 mm thickness
MORTH Specification No.516 (PWD SR2009-10/P.No.156/21.66)

KSRRB M500-Crack Prevention Courses


21.67 KSRRB M500-57.1. Providing and laying of a stress absorbing membrane
over a Cracked road surface, with crack width below 6 mm after cleaning
with a mechanical broom, using modified binder complying with clause
500.21, sprayed at the rate of 9 kg per 10 sqm and spreading 5.6 mm
crushed stone aggregates at 0.11 cum per 10 sqm with hydraulic chip
spreader, sweeping the surface for uniform spread of aggregates and Sqm 43.00
surface finished to conform 900.2 complete as per specifiction. Case-I:
Stress absorbing membrane (SAM) crack width less than 6mm.
MORTH Specification No. 522 (PWD SR2009-10/P.No.156-157/21.67)

21.68 KSRRB M500-57.2. Providing and laying of a stress absorbing membrane


over a cracked road surface, with crack width 6 to 9 mm after cleaning with
a mechanical broom, using modified binder complying with clause 500.21,
sprayed at the rate of 11 kg per 10 sqm and spreading 11.2 mm crushed
stone aggregates at 0.12 cum per 10 sqm, sweeping the surface for
uniform spread of aggregates and surface finished to conform to clause Sqm 52.00
900.2 complete as per specification. Case-II: Stress absorbing
membrane (SAM) crack width 6 mm to 9 mm" MORTH Specification No.
522. (PWD SR2009-10/P.No157/21.68)

21.69 KSRRB M500-57.3. Providing and laying a single coat of a stress


absorbing membrane over a cracked road surface, with crack width above
9 mm and cracked area above 50% after cleaning with a mechanical
broom, using modified binder complying with clause 500.21, sprayed at the
rate of 15 kg per 10 sqm and spreading 11.2 mm crushed stone
aggregates at 0.12 cum per 10 sqm, sweeping the surface for uniform
Sqm 68.00
spread of aggregates and surface finished to conform to clause 900.2
complete as per specification. Case-III: Stress absorbing membrane (SAM)
crack width above 9 mm and cracked aread above 50%. MORTH
Specification No. 522. (PWD SR2009-10/P.No157/21.69)

21.70 KSRRB M500-57.4. Providing and laying a bitumen impregnated geotextile


layer after cleaning the road surface, geotextile conforming to
requirements of clause 700.3.3, laid over a tack coat with 1.05 kg per sqm
of paving grade bitumen 80-100 penetration and constructed to the Sqm 115.00
requirement of clause 700.3.4.5 complete as per specification. Case-IV:
Bitumen impregnated geotextile. MORTH Specification No. 522 (PWD
SR2009-10/P.No157/21.70)

KSRRB M500-Recipe Cold Mixes


21.71 KSRRB M500-58.1. Providing and laying of premix of crushed stone
aggregates and emulsion binder, mixed in a batch type cold mixing plant,
laid over prepared surface, by paver finisher, rolled with a peneumatic
tyred roller initially and finished with a smooth steel wheel roller, all as per Cum 4920.00
clause 500.19.3 complete as per specifications. Case-I : 75 mm
thickness. MORTH Specification No. 519.3 (PWD SR2009-
10/P.No157/21.71)

21.72 KSRRB M500-58.2. Providing and laying of premix of crushed stone


aggregates and emulsion binder, mixed in a batch type cold mixing plant,
laid over prepared surface, by paver finisher, rolled with a peneumatic
tyred roller initially and finished with a smooth steel wheel roller, all as per Cum 6700.00
clause 500.19.3 complete as per specifications. Case-II : 40 mm
thickness. MORTH Specification No. 519.3 (PWD SR2009-
10/P.No158/21.72)
21.73 KSRRB M500-58.2. Providing and laying of premix of crushed stone
aggregates and emulsion binder, mixed in a batch type cold mixing plant,
laid over prepared surface, by paver finisher, rolled with a peneumatic
tyred roller initially and finished with a smooth steel wheel roller, all as per Cum 7520.00
clause 500.19.3 complete as per specifications. Case-II : 25 mm
thickness. MORTH Specification No. 519.3 (PWD SR2009-
10/P.No158/21.73)

CONCRETE PAVEMENT
KSRRB M600- Cement concrete Pavements
22.1 KSRRB M600-1. Construction of dry lean Cement concrete Sub-base over
a prepared sub-grade with course and fine aggregates conforming to IS:
383, the size of coarse aggregate not exceeding 25 mm, aggregate
cement ratio not to exceed 15:1, aggregate gradation after blending to be
as per Table 600-1, cement content no to be less than 150 kg/cum,
optimum moisture content to be determined during trial length
Cum 2300.00
construction, concrete strength not to be less than 10 Mpa at 7 days,
mixed in a batching plant, transported to site, laid with a paver with
electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing
and curing complete as per specifications. MORTH Specification No.601.
(PWD SR2009-10/P.No160/22.1).

22.2 KSRRB M600-2. Cement concrete Pavement :- Construction of un-


reinforced, dowel jointed, plain cement concrete pavement over a
prepared Sub-base with 43 grade cement at 400 kg per cum, coarse and
fine aggregates conforming to IS: 383, maximum size of coarse aggregate
not exceeding 25 mm, mixed in a batching and mixing plant as per
approved mix design, transported to site, laid with a fixed form or slip form
paver, spread, compacted and finished in a continuous operation including
provision of contraction, expansion, construction and longitudinal joints, Cum 4900.00
joint filler, separation membrane, sealant primer, joint sealant, debonding
strip, dowel bar, tie rod, admixtures as approved, curing compound,
finishing to lines and grades as per drawing complete as per
specifications. MORTH Specification No. 602. (PWD SR2009-
10/P.No160/22.2).

22.3 KSRRB M600-3. Construction of Rolled Cement concrete base course


with coarse and fine aggregates conforming to IS: 383, the size of coarse
aggregate not exceeding 25 mm, with minimum, aggregate cement ratio
15:1, and minimum cement content of 200 kg/cum, aggregate gradation to
be as per Table 600-4 after blending, mixing in batching plant at optimum
moisture content, transporting to site, laying with a paver with electronic Cum 2580.00
sensor, compacting with 8-10 tonnes smooth wheeled vibratory roller to
achieve, the designed flexural strength, finishing and curing complete as
per specifications. MORTH Specification No.603. (PWD SR2009-
10/P.No160/22.3).

KSRRB M600- Construction of Base / Sub-base of pavement with


Lean Concrete flyash
22.4 KSRRB M600-5. Construction of Base / Sub-base using cement, sand,
flyash and coarse aggregates proportioned as per table 4 of IRC: 74/1979
and with water cement ratio, slump and compressive strength as defined in
the said table, mix prepared in a batching and mixing plant and compacted
with a vibratory roller 8-10 tonnes capacity within the time limit laid down
vide clause 700.6.3 of IRC: 74-1979, construction joints properly formed at Cum 2125.00
the end of day's work, cured for 14 days, all as specified in IRC: 74-1979
and as per approved plans complete as per specifications. MORTH
Specification No. Suggestive.MORTH Specification No.603. (PWD
SR2009-10/P.No160-161/22.4).

KSRRB M600-Cement-Flyash concrete pavement


22.5 KSRRB M600-6. Construction reinforced, dowel jointed, plain cement
concrete pavement over a prepared sub base with 43 grade cement,
coarse and fine aggregates conforming to IS: 383, maximum size of
course aggregate not exceeding 25 mm, replacing cement by fly ash to the
extent of 15% and sand by 10%, mixed in a batching and mixing plant as
per approved mix design, transported to site, laid with a fixed form or slip
form paver, spread, compacted and finished in a continuous operation
including provision of contraction, expansion, construction and longitudinal Cum 4525.00
joints, joint filler, separation membrane, sealant primer, joint sealant,
debonding strip, dowel bar, tie rod, admixtures as approved, curing
compound, finishing to lines and grades as per drawing complete as per
specifications. MORTH Specification No. Suggestive.MORTH Specification
No.603. (PWD SR2009-10/P.No.161/22.5).

22.6 KSRRB M600-6. Cement concrete pavement, Construction un-reinforced,


plain cement concrete pavement, thickness as per design, over a prepared
sub base with 43 grade cement or any other type as per clause
1051.2.2M20/M30 at 380/450 kg per cum, coarse and fine aggregates
conforming to IS: 383, maximum size of course aggregate not exceeding
25 mm, mixed in a concrete mixer of not less than 0.6 cum capacity and
appropriate weigh batcher as per approved mix design, laid in approved
fixed side form work (steel channel, laying and fixing of 125 micron thick
polythene film, wedges, steel plates including levelling the form work as
per drawing) Spreading the concrete with shovels, rackers compacted
using needle, screed the plate vibrator and finished in a continuous
operation including provision of contration, expanshion, construction and
longitudinal joints, joint filler, separation membrane, selant primer, joint
sealant, admixtures as approved curing compound, finishing to lines and
grades as per drawing complete as per specifications (PWD SR2009-
10/P.No.161/22.6).

22.6.1
KSRRB M600-6. Cement concrete pavement, Construction un-reinforced,
plain cement concrete pavement, thickness as per design, over a prepared
sub base with 43 grade cement or any other type as per clause
1051.2.2M20/M30 at 380/450 kg per cum, coarse and fine aggregates
conforming to IS: 383, maximum size of course aggregate not exceeding
25 mm, mixed in a concrete mixer of not less than 0.6 cum capacity and
appropriate weigh batcher as per approved mix design, laid in approved
fixed side form work (steel channel, laying and fixing of 125 micron thick
Cum 4450.00
polythene film, wedges, steel plates including levelling the form work as
per drawing) Spreading the concrete with shovels, rackers compacted
using needle, screed the plate vibrator and finished in a continuous
operation including provision of contration, expanshion, construction and
longitudinal joints, joint filler, separation membrane, selant primer, joint
sealant, admixtures as approved curing compound, finishing to lines and
grades as per drawing complete as per specifications (PWD SR2009-
10/P.No.161/22.6.1). M30 (at 450 kg per cum)
22.6 KSRRB M600-6. Cement concrete pavement, Construction un-reinforced,
plain cement concrete pavement, thickness as per design, over a prepared
sub base with 43 grade cement or any other type as per clause
1051.2.2M20/M30 at 380/450 kg per cum, coarse and fine aggregates
conforming to IS: 383, maximum size of course aggregate not exceeding
25 mm, mixed in a concrete mixer of not less than 0.6 cum capacity and
appropriate weigh batcher as per approved mix design, laid in approved
fixed side form work (steel channel, laying and fixing of 125 micron thick
polythene film, wedges, steel plates including levelling the form work as
per drawing) Spreading the concrete with shovels, rackers compacted Cum 4050.00
using needle, screed the plate vibrator and finished in a continuous
operation including provision of contration, expanshion, construction and
longitudinal joints, joint filler, separation membrane, selant primer, joint
sealant, admixtures as approved curing compound, finishing to lines and
grades as per drawing complete as per specifications (PWD SR2009-
10/P.No.161/22.6.1). M20 (at 380 kg per cum)

GEOSYNTHETIC AND REINFORCED EARTH


23.1 KSRRB M700-1. Construction of sub surface drain 200 mm dia using
geotextilestreated with carbon black with physical properties as given in
clause 700.2.2.3 formed in to a stable network and a planar
geocomposites structure, joints wrapped with geotextiles to prevent m 425.00
ingress of soil, all as per clause 700.2 and approved drawings including
excavation and backfilling complete as per specifications. MORTH
Specification No. 702.(PWD SR2009-10/P.No.163/23.1).

23.2 KSRRB M700-2. Construction of a narrow filter sub surface drain Narrow
Filter Sub-surface Drain consisting of porous or perforated pipe laid in
narrow trench surrounded by a geotextiles filter fabric, with a minimum of
450 mm overlap of fabric and installed as per clause 700.2.2.3 and m 530.00
300.9.3.5 including excavation and backfilling complete as per
specifications. MORTH Specification No. 702.4(PWD SR2009-
10/P.No.163/23.2).

23.3 KSRRB M700-3. Laying Paving Fabric Beneath a Pavement Overlay:-


Providing and laying paving fabric with physical requirements as per Table
704-2 over a tack coat of paving grade Bitumen 80-100 penetration, laid at
the rate of 1 kg per sqm over thoroughly cleaned and repaired surface to
provide a water resistant membrane and crack retarding layer. Paving
fabric to be free of wrinkling and folding and to be laid before cooling of Sqm 59.00
tack coat, brooming and rolling of surface with pneumatic roller to
maximise paving fabric contact with pavement surface complete as per
specifications. MORTH Specification No. 703. (PWD SR2009-
10/P.No.163/23.3).
23.4 KSRRB M700-4. Laying Boulder Apron in crates of Synthetic Geogrids:-
Providing, preparing and laying of geogrids created apron 1 m x 5 m, 600
mm thick including excavation and backfilling with baffles at 1 metre
interval, made with geogrids having characteristics as per clause 700.4.2,
joining sides with connectors/ring staples, top corners to be tie tensioned,
placing of suitable cross interval tiles in layers of 300 mm connecting
opposite side with lateral braces and tied with polymer braids to avoid
bulging, constructed as per clause 700.4.3. filled with stone with minimum Cum 3545.00
size of 200 mm and specific gravity not less than 2.65, packed with stone
spalls, keyed to the foundation recess in case of sloping ground and laid
over a layer of geotextiles to prevent migration of fines, all as per clause
700.4 and laid as per clause 200.5.3.3 and approved design complete a as
per specifications. MORTH Specification No. 704. (PWD SR2009-
10/P.No.163/23.4).

TRAFFIC SIGNS, MARKINGS & OTHER ROAD


APPURTENANCES
Sl. Description Rate
Unit
No. Rs. Ps.

24.1 KSRRB 800-1 : Painting two coats after filling the surface with synthetic
enamel paint in approved shades on new plastered concrete surfaces with
materials, labour complete as per specification, MORTH Chapter 8 (PWD Sqm 39.00
SR2009-10/P.No. 165/24.1)

24.2 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2)

24.2.1 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 1510.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) i) 90 cm equilaterial triangle

24.2.2 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 1460.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) ii) 60 cm equilaterial triangle
24.2.3 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of
retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of No 1480.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) iii) 60 cm Circular

24.2.4 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of No 1520.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) iv) 80 mm x 60 mm Rectangular

24.2.5 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 1480.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) v) 60 cm x 45 cm Rectangular

24.2.6 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 1500.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) vi) 60 cm x 60 cm Square

24.2.7 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
properly designed foundation with M 15 grade cement concrete 45 cm x 45 No 1560.00
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2009-
10/P.No. 165/24.2.1) vi) 90 cm high octagon

24.3 KSRRB M800-3. Direction and Place Identification Signs upto 0.9 sqm
Size Board:- Providing and erecting direction and place identification
retro-reflectorised sign as per IRC:67 made of high intensity grade
sheeting vide clause 800.1.3, fixed over aluminium sheeting, 2 mm thick
with area not exceeding 0.9 sqm supported on a mild steel single angle
iron post 75 x75 x 6 mm firmly fixed to the ground by means of properly Sqm 1820.00
designed foundation with M-15 grade cement concrete 45 x 45 x 60 cm, 60
cm below ground level as per approved drawing complete as per
specifications. MORTH Specification No.801.(PWD SR2009-10/P.No.
165/24.3)
24.4 KSRRB M800-4. Direction and Place Identification Signs with size
more than 0.9 sqm Size Board:- Providing and erecting direction and
place identification retro-reflectorised sign as per IRC:67 made of high
intensity grade sheeting vide clause 800.1.3, fixed over aluminium
sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild
steel single angle iron post 75 x75 x 6 mm, 2 Nos. firmly fixed to the Sqm 2120.00
ground by means of properly designed foundation with M-15 grade cement
concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved
drawing complete as per specifications. MORTH Specification No.801.
(PWD SR2009-10/P.No. 165/24.4)

24.5 KSRRB M800-5.1. Over head Signs:- Providing and erecting overhead
signs with a corrosion resistant 2 mm thick aluminium alloy sheet
reflectorised with high intensity retro-reflective sheeting of encapsulated
lense type with vertical and lateral clearance given in clause 800.2.2 and
800.2.3 and installed as per clause 800.2.7, over a designed support Tonne 70460.00
system pf aluminium alloy or galvanished steel trestles and trusses of
sections and type as per structural design requirements and approved
plans complete as per specifications. A. Truss and Vertical Support
MORTH Specification No.802.(PWD SR2009-10/P.No. 166/24.5)

24.6 KSRRB M800-5.2. Providing and erecting overhead signs with a corrosion
resistant 2 mm thick aluminium alloy sheet reflectorised with high intensity
retro-reflective sheeting of encapsulated lense type with vertical and lateral
clearance given in clause 800.2.2 and 800.2.3 and installed as per clause
800.2.7, over a designed support system pf aluminium alloy or galvanished
steel trestles and trusses of sections and type as per structural design Sqm 2500.00
requirements and approved plans complete as per specifications. B.
Aluminium Alloy Plate for Over Head Sign MORTH Specification
No.802.(PWD SR2009-10/P.No. 166/24.6)

KSRRB M800-Painting Letters


24.7 KSRRB M800-6. Painting Two coats on New Concrete Surface:- Painting
two coats after filling the surface with synthetic enamel paint in all shades
on new plastered concrete surfaces complete as per specifications. Sqm 45.00
MORTH Specification No. 803.(PWD SR2009-10/P.No. 166/24.7)

24.8 KSRRB M800-7. Painting:- Painting and applying Two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803.
(PWD SR2009-10/P.No. 166/24.8)

24.8.1 KSRRB M800-7. Painting:- Painting and applying Two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803. Sqm 39.00
Painting on Steel Surface (PWD SR2009-10/P.No. 166/24.8.1)

24.8.2 KSRRB M800-7. Painting:- Painting and applying Two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803. Sqm 45.00
Painting on Wood Surface (PWD SR2009-10/P.No. 166/24.8.2)
24.9 KSRRB M800-9. Painting New Letter and figures of any Shade with
synthetic enamel paint black or any other approved colour to give an even
shade complete as per specifications. ("i) Hindi (Matras commas and the Cm 0.40
like not to be measured and paid for half letter shall be counted as half)
MORTH Specification No.801 (PWD SR2009-10/P.No. 166/24.9)

24.10 KSRRB M800-10. Painting New Letter and figures of any Shade with
synthetic enamel paint black or any other approved colour to give an even
shade complete as per specifications. ("ii) English and Roman-Hyphen and Cm 0.25
the like not to be measured and paid for MORTH Specification No.801
(PWD SR2009-10/P.No. 166/24.9)

24.11 KSRRB M800-11.1. Painting lines, dashes, arrows etc., on Roads in


two coats on New Work:- Painting lines, dashes, arrows etc., on Roads
in two coats on New Work with ready mixed road marking paint
conforming to IS:164 on Bituminous surface, including cleaning the surface
Sqm 90.00
of all dirt, dust and other foreign matter, demarcation at site and traffic
control complete as per specifications. i) Over 10 cm in width. MORTH
Specification No.803 (PWD SR2009-10/P.No. 167/24.11)

24.12 KSRRB M800-11.2. Painting lines, dashes, arrows etc., on Roads in


two coats on New Work:- Painting lines, dashes, arrows etc., on Roads
in two coats on New Work with ready mixed road marking paint
conforming to IS:164 on Bituminous surface, including cleaning the surface Sqm 83.00
of all dirt, dust and other foreign matter, demarcation at site and traffic
control complete as per specifications. ii) Upto10 cm in width. MORTH
Specification No.803 (PWD SR2009-10/P.No. 167/24.12)

24.13 KSRRB M800-12.1. Painting lines, dashes, arrows etc., on Roads in


two coats on Old Work:- Painting lines, dashes, arrows etc., on Roads in
two coats on old Work with ready mixed road marking paint conforming to
IS:164 on Bituminous surface, including cleaning the surface of all dirt, Sqm 65.00
dust and other foreign matter, demarcation at site and traffic control
complete as per specifications. i) Over 10 cm in width. MORTH
Specification No.803 (PWD SR2009-10/P.No. 167/24.13)

24.14 KSRRB M800-12.2. Painting lines, dashes, arrows etc., on Roads in


two coats on Old Work:- Painting lines, dashes, arrows etc., on Roads in
two coats on old Work with ready mixed road marking paint conforming to
IS:164 on Bituminous surface, including cleaning the surface of all dirt, Sqm 62.00
dust and other foreign matter, demarcation at site and traffic control
complete as per specifications. ii) Upto 10 cm in width. MORTH
Specification No.803 (PWD SR2009-10/P.No. 167/24.14)

24.15 KSRRB M800-13.Road Marking with Hot Applied Thermoplastic


Compound with Reflectrising Glass Beads on Bituminous Surface:-
Providing and laying of hot applied thermoplastic compound 2.5 mm thick
including reflectorising glass beads at 250 gms per sqm area, thickness of
2.5 mm is exclusive of surface applied glass beads as per IRC:35. The Sqm 390.00
finished surface to be level, uniform and free from streaks and holes
complete as per specifications. MORTH Specification No.803 (PWD
SR2009-10/P.No. 167/24.15)

KSRRB 800- Kilometre Stone


24.16 KSRRB 800-14.1. Reinforced cement concrete M-15 Grade kilometre
stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications. i) 5th kilometre Nos 2220.00
Stone (Precast) MORTH Specification No.804 (PWD SR2009-10/P.No.
167/24.16)
24.17 KSRRB 800-14.2. Reinforced cement concrete M-15 Grade kilometre
stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications. ii) Ordinary Nos 1400.00
kilometre Stone (Precast) MORTH Specification No.804 (PWD SR2009-
10/P.No. 167/24.17)

24.18 KSRRB 800-14.3. Reinforced cement concrete M-15 Grade kilometre


stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications. iii) Hectometre Nos 360.00
Stone (Precast) MORTH Specification No.804 (PWD SR2009-10/P.No.
168/24.18)

24.19 KSRRB 800-15. Road Delineators:- Supplying and installation of


delineators (road way indicators, hazard Markers, Object markers), 80-100
cm high above ground level, painted black and white in 15 cm wide strips,
fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised
panels at the top, buried or pressed into the ground and conforming to Nos 335.00
IRC-79 and the drawings complete as per specifications. iii) Hectometre
Stone (Precast) MORTH Specification No.805 (PWD SR2009-10/P.No.
168/24.19)

24.20 KSRRB 800-16. Boundary Pillar:- Reinforced cement concrete M-15


grade boundry pillars of standard design as per IRC:25-1967 fixed in
position including finishing and lattering but excluding painting complete as Nos 280.00
per specifications. MORTH Specification No.806 (PWD SR2009-10/P.No.
168/24.20)

KSRRB M800-Fencing / Railing


24.21 KSRRB M800-17. G.I. Barbed Wire Fencing 1.2 Metro High. Providing
and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron
posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center
founded in M15 grade cement concrete, 0.6 metre below ground level,
every 15th post, last but one end post and corner post shall be strutted on
both sides and end post on one side only and provided with 9 horizontal m 180.00
lines and 2 diagonals interwoven with horizontal wires, fixed with GI
staples, turn buckles etc complete as per clause 800.7 as per
specifications. MORTH Specification No. 807 (PWD SR2009-10/P.No.
168/24.21)

24.22 KSRRB M800-18. G.I. Barbed Wire Fencing 1.8 Metro High. Providing
and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron
posts 50 mm x 50 mm x 6 mm placed every 3 metres center to center
founded in M15 grade cement concrete, 0.6 metre below ground level,
every 15th post, last but one end post and corner post shall be strutted on
both sides and end post on one side only and provided with 12 horizontal m 335.00
lines and 2 diagonals interwoven with horizontal wires, fixed with GI
staples, turn buckles etc complete as per clause 800.7 as per
specifications. MORTH Specification No. 807 (PWD SR2009-10/P.No.
168/24.22)

24.23 KSRRB M800-19. Fencing with Welded Steel Wire Fabric 75 mm x 50


mm :- Providing 1.20 metre high fencing with angle iron posts 50 mm x 50
mm x 6 mm at 3 metres center to center with 0.40 metre embedded in
M15 grade cement concrete, corner end and every 10th post to be
strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or
m 480.00
75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and
bolts etc., complete in all respects as per clause 800.7 as per
specifications. MORTH Specification No Suggestive (PWD SR2009-
10/P.No. 168/24.23)
24.24 KSRRB M800-20. Tubular Steel Railing on Medium Weight Steel
Channel (ISMC Series) 100 mm x 50 mm:- Providing fixing and erecting
50 mm dia steel pipe railling in 3 rows duly painted on medium weight steel
channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground,
m 880.00
2 m centre to centre, complete as per approved drawings as per
specifications. MORTH Specification No 808. (PWD SR2009-10/P.No.
168-169/24.24)

24.25 KSRRB M800-21. Tubular Steel Railing on Precast RCC Posts, 1.2 m
High Above Ground Level:- Providing, fencing and erecting 50 mm dia
painted steel pipe railing in 3 rows on precast M-20 Grade RCC vertical
posts 1.8 metres high (1.2 m above GL) with 3 holes 50 mm dia for pipe, m 620.00
fixed 2 metres centre to, complete as per approved drawings as per
specifications. MORTH Specification No 808. (PWD SR2009-10/P.No.
169/24.25)

KSRRB M800-Crash Barrier


24.26 KSRRB M800-22. Reinforced cement Concrete Crash Barrier:-
Provision of an Reinforced cement concrete crash barrier at the edges of
the road, approaches to bridges structures and medians, constructed with
M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and
dowel bars 25 mm dia, 450 mm long at expanshion joints filled with pre-
moulded asphalt filler board, keyed to the structure on which it is built and
installed as per design given in the enclousure to MOST circular No. RW / m 2250.00
NH - 33022/1/194-DO III dated 24 june 1994 as per dimensions in the
approved drawing and at locaions directed by the Engineer, all as
specified complete as per approved drawings as per specifications.
MORTH Specification No 809. (PWD SR2009-10/P.No. 169/24.26)

24.27 KSRRB M800-23.1. Metal Beam Crash Barrier:- Providing and erecting a
"W" metal beam crash barrier comprising of 3 mm thick corrugated
sheet ,metal beam rail, 70 cm above road / ground level, fixed on ISMC
series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre,
1.8 m high, 1.1 m below ground / road level, all steel parts and fitments to
be galvanished by hot dip process, all fittings to conform to IS: 1367 and
IS: 1364, metal beam rail to be fixed on the vertical post with a spacer of m 1870.00
channel section 150 x 75 x 5 mm, 330 m long complete as per clause
800.10 complete as per specifications. A. Type-A, "W" MORTH
Specification No 810. (PWD SR2009-10/P.No. 169/24.27)

24.28 KSRRB M800-23.2. Metal Beam Crash Barrier:- Providing and erecting a
"Thrie" metal beam crash barrier comprising of 3 mm thick corrugated
sheet ,metal beam rail, 85 cm above road / ground level, fixed on ISMC
series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre,
2 m high, 1.15 m below ground level, all steel parts and fitments to be
galvanished by hot dip process, all fittings to conform to IS: 1367 and IS: m 2950.00
1364, metal beam rail to be fixed on the vertical post with a spacer of
channel section 150 x 75 x 5 mm, 546 m long complete as per clause
800.10 complete as per specifications. B. Type-B, "Thrie" MORTH
Specification No 810. (PWD SR2009-10/P.No. 169/24.28)
24.29 KSRRB M800-24. Flexible Crash Barrier, Wire Ropes Safety Barrier:-
Providing and erecting a wire rope safety barrier with vertical posts of
medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m),
1.50 m long 0.85 m above ground and 0.65 m below ground level, split at
the bottom for better grip, embedded in M-15 Grade cement concrete 450
x 450 x 450 mm, 1.50 m center to center and with 4 horizontal steel wire
rope 40 mm dia and anchored at terminal posts 15 m apart. Terminal post
to be embedded in M 15 grade cement concrete foundation 2400 x 2400 x m 1820.00
450x 900 mm (depth), strengthened by a strut of RS joist 100 mm x 75
mm, 2 m long at 45' inclination and a tie 100 x 8 mm, 1.50 m long at the
bottom, all embedded in foundation concrete as per approved design and
drawing, rate excluding excavation and cement concrete complete as per
specifications. MORTH Specification No Suggestive. (PWD SR2009-
10/P.No. 169-170/24.29)

KSRRB M800-Anti-Glare devices in Median


24.30 KSRRB M800-26.2. Providing and erecting an Anti-Glare screen with 25
mm dia vertical pipes fabricated and framed in the form of panels of one
metre length and 1.75 metre height fixed with circular vane 250 mm dia at
top abd rectangular vane 600 x 300 mm at the middle, made out of steel
sheet of 3 mm thickness, end vertical pipes of the panel made larger for
embedding in foundation concrete, applying 2 coats of paint on all Each 4600.00
exposed surfaces, all as per approved design and drawings complete as
per specifications. B. Anti-glare screen with 25 mm steel pipe framework
fixed with circular and rectangular vanes. MORTH Specification No.
Suggestive (PWD SR2009-10/P.No. 170/30)

24.31 KSRRB M800-26.3. Providing and erecting an Anti-Glare screen with


rectangular vanes of size 750 x 500 mm made from MS sheet, 3 mm thick
and fixed on MS angle 50 x 50 x 6 mm at an angle of 45' to the direction
of flow of traffic, 1.5 m center to center, top edge of the screen 1.75 m
above ground level, vertical post firmly embedded in M-15 cement
concrete foundation 0.60 m below ground level, applying 2 coats of paint m 690.00
on exposed faces, all complete as per approved design and drawings
complete as per specifications. C. Anti-glare screen with rectangular vane
MS sheet. MORTH Specification No. Suggestive (PWD SR2009-10/P.No.
170/31)

KSRRB M800 - Street lighting


24.32 KSRRB M800 - 27. Providing and erecting Street light mounted on a steel
circular hollow pole of standard specifications for street lighting, 9 m high
spaced 40 m apart, 1.8 m overhang on both sides if fixed in the median
and on one side if fixed on the footpath, fitted with sodium vapour lamp
Each 10820.00
and fixed firmly in concrete foundation complete as per specifications.
MORTH Specification No. Suggestive. (PWD SR2009-10/P.No. 170/24.32)

24.33 KSRRB M800 - 28. Lighting On Bridges:- Providing and fixing lighting on
bridges, mounted on steel hollow circular poles of standard specifications,
5 m high fixed on parpets with cement concrete, 20 m apart and fitted with
sodium vapour lamp complete as per specifications. MORTH Specification Each 7100.00
No. Suggestive. (PWD SR2009-10/P.No. 170/24.33)

KSRRB M800 - Cable Duct Across the Road


24.34 KSRRB M800 - 29.1. Providing and laying of a reinforced cement
Concrete pipe duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to toe of slope in fills,
constructing head walls at both ends, providing a minimum fill of fills,
constructing head walls at both ends, providing a minimum fill of granular
material over top and sides of RCC pipe as per IRC: 98-1997, bedded on a
0.3 m thick layer of granular material free of rock pieces, outer to outer
distance of pipe at least half dia of pipe subject to minimum 450 mm in m 1230.00
case of double and triple row ducts, joints to be made leak proof, invert
level of duct to be above higher than ground level to prevent entry of
water and dirt, all as per IRC: 98 - 1997 and approved drawings complete
as per specifications. Case-1: Single row for one utility service (PWD
SR2009-10/P.No. 171/24.34)

24.35 KSRRB M800 - 29.2. Providing and laying of a reinforced cement


Concrete pipe duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to toe of slope in fills,
constructing head walls at both ends, providing a minimum fill of fills,
constructing head walls at both ends, providing a minimum fill of granular
material over top and sides of RCC pipe as per IRC: 98-1997, bedded on a
0.3 m thick layer of granular material free of rock pieces, outer to outer
distance of pipe at least half dia of pipe subject to minimum 450 mm in m 2330.00
case of double and triple row ducts, joints to be made leak proof, invert
level of duct to be above higher than ground level to prevent entry of
water and dirt, all as per IRC: 98 - 1997 and approved drawings complete
as per specifications. Case-II : Double row for two utility services (PWD
SR2009-10/P.No. 171/24.35)

24.36 KSRRB M800 - 29.3. Providing and laying of a reinforced cement


Concrete pipe duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to toe of slope in fills,
constructing head walls at both ends, providing a minimum fill of fills,
constructing head walls at both ends, providing a minimum fill of granular
material over top and sides of RCC pipe as per IRC: 98-1997, bedded on a
0.3 m thick layer of granular material free of rock pieces, outer to outer
distance of pipe at least half dia of pipe subject to minimum 450 mm in m 3450.00
case of double and triple row ducts, joints to be made leak proof, invert
level of duct to be above higher than ground level to prevent entry of
water and dirt, all as per IRC: 98 - 1997 and approved drawings complete
as per specifications. Case-III : Triple row for three utility services (PWD
SR2009-10/P.No. 171/24.36)

KSRRB M800- Gantry mounted variable message sign board


24.37 KSRRB M800-33.1. Providing and erecting Gantry mounted variable
message sign board electronically operated capable of flashing the desired
message over a designed support system of aluminium alloy of
galvanished steel, erected as per approved design and drawings and with Tonne 68000.00
lateral clearance as per clause 800.2.3 complete as per specifications i)
Gantry Support System (PWD SR2009-10/P.No. 171/24.37)

KSRRB M800-34 Traffic Input attenuators at abutments and piers


24.38 KSRRB M800-34.1. Providing and installation of Traffic attenuators at
abutment / pier of flyovers bridges using scrap tyres of size
100 x 20 retrieved from trucks laid in 2 rows and 4 tiers, one above
the other and tied with 20 mm wire rope as per approved design and Sqm 620.00
drawings complete as per specifications (PWD SR2009-10/P.No.
171/24.38)
24.39 KSRRB M800-34.2. Providing and installation of Traffic impact attenuators
at abutment / pier of flyovers bridges using plastic / steel barrels 0.60 m
dia and 1.0 m in height, filled with sand in three rows and tied with 20 mm
wire rope as per approved design and drawings complete as per Sqm 680.00
specifications B. Using Plastic / Steel Barrel, Filled with sand. (PWD
SR2009-10/P.No. 171/24.39)

24.40 KSRRB M800-34.3. Providing and installing a patentend HI - DRO cell


system as a Traffic impact attenuators, using plastic tubes 50 cm dia, 1.2
m in height, 25 mm opening at the top, placed in three rows, filled with
water and tied with a 20 mm steel wire rope complete as per
specifications. (In this patented HI - DRO cell system, water gets Sqm 1200.00
discharged from plastic tubes on impact over a pre-determined time, thus
absorbing the energy) C. With HI - DRO Cell Sandwich (Patented) (PWD
SR2009-10/P.No. 171/24.40)

KSRRB M800 Road Markers / Road Stud


24.41 KSRRB M800-35. Providing and fixing of road stud 100 x 100 mm, die-
cast in aluminium, resistant to corrosive effect of salt and grit, fitted with
lense reflectors, installled in concrete or asphaltic surface by drilling hole
30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout Nos 265.00
or epoxy mortar, all as per BS: 873 part 4:1973 Complete as per
specifications (PWD SR2009-10/P.No. 171-172/24.41)

KSRRB M800 - Traffic cone


24.42 KSRRB M800 - 36. Provision of red flurescent with white reflective sleeve
traffic cone made of low density polyethylene (LDPE) material with a
square base of 390 x 390 x 35 mm and a height of 770 mm, 4 kg in Nos 480.00
weight, placed at 1.5 m interval, all as per BS: 873 complete as per
specifications (PWD SR2009-10/P.No. 172/24.42)

KSRRb M800- Policeman umbrella


24.43 KRRRB M800-39. Provosion of a 2 m high (floor to roof) umbrella for traffic
policeman at road crossings. where necessay, installed on a raised
platform, built on a central support of a steel pipe 100 mm dia, roof made
of 25 mm dia steel pipe to provide covered area of 3 sqm, roofed with CGI Nos 2080.00
sheets, all steel parts to be given 2 coats of paint complete as per
specifictions. (PWD SR2009-10/P.No. 172/24.43)

KSRRB M800-Portable barricade in construction zone


24.44 KSRRB M800-43. Installation of a steel Portable barricade with horizontal
rail 300 mm wide, 2.5 m in length fitted on a 'A' frame made with 45 X 45
X 5 mm angle iron section, 1.5 m in height, horizontal rail painted (2 coats)
with yellow and white stripes, 150 mm in width at an angle of 45', 'A' frame Each 2170.00
painted with 2 coats of yellow paint, complete as per IRC: SP:55-2001
complete as per specifications. (PWD SR2009-10/P.No. 172/24.44)

KSRRB M800-Permanent type barricade in construction zone


24.45 KSRRB M800-44.1. Construction of a permanent type barricade made of
steel components,1.5 m high from road level, fitted woth 3 horizontal rails
200 mm wide and 4 m long on 50 X 50 X 5 mm angle iron vertical support,
painted with yellow and white stripes, 150 mm in width at an angle of 45',
Each 3500.00
complete as per IRC: SP:55-2001 complete as per specifications.A. With
steel components (PWD SR2009-10/P.No. 172/24.45)
24.46 KSRRB M800-44.2. Construction of a permanent type barricade made of
wooden components,1.5 m high from road level, fitted woth 3 horizontal
planks 200 mm wide and 3.66 m long on 100 X 100 mm wooden vertical
post, painted with yellow and white stripes, 150 mm in width at an angle of Each 4580.00
45', complete as per IRC: SP:55-2001 complete as per specifications.B.
With Wooden components (PWD SR2009-10/P.No. 172/24.46)

24.47 KSRRB M800-44.3. Construction of a permanent type barricade made with


brick work in mud mortar,1.5 m high, 4 m long, 600 mm thick, plastered
with cement mortar 1:6, painted with yellow and white stripes, complete as Each 10150.00
per specifications.C. With Bricks (PWD SR2009-10/P.No. 172/24.47)

KSRRB M800-Drum delineator in construction zone


24.48 KSRRB M800-45. Provision of metal drum / empty bitumen drum
delineator, 300 mm in diameter, 800 mm high, filled with earth for stability,
painted in circumferntial strips of alternate black and white 100 mm wide
fitted with reflectors 3 nos of 7.5 cm dia, all as per IRC: SP:55-2001 Each 910.00
complete as per specifications. (PWD SR2009-10/P.No. 173/24.48)

KSRRB M800-Flagman
24.49 KSRRB M800-46. Positioning of a smart Flagman with a yellow vest and a
yellow cap and a red flag 600 x 600 mm securely fastened to a staff 1 m in
length for guiding the traffic complete as per specifications (PWD SR2009- Each 230.00
10/P.No. 173/24.49)

24.50 Supplying and fixing in position new guard stones of granite / trap / sand
stone / shahabad roughly dressed, of size 700 mm x 200 mm x 200 mm
including excavation, painting with white and black paint 15 cm wide strip Each 109.00
alternatively etc., complete (PWD SR2009-10/P.No. 173/24.50)

24.51 Removing and varifying guard stones / KM stones/ boundary stones, in a


complete manner embedded in earth excluding painting.(PWD SR2009- Each 17.00
10/P.No. 173/24.51)

BRIDGES - PILE FOUNDATION


Sl. Description Rate
Unit
No. Rs. Ps.

25.1 KSRRB 1100-1 : Bored / Cast-in-situ R.C.C. M 20,1000mm dia. piles


excluding reinforcement as per drawings including cost of all materials,
labour, HOM of machineries complete as per specifications. m 13700.00
MORTH Chapter 12 (PWD SR2009-10/P.No. 175/25.1)

25.2 KSRRB 1100-2 : Driving Cast-in-place m20 grade vertical R.C.C, 500mm
dia. piles excluding reinforcement as per drawings including cost of all
materials, labour, HOM of machineries complete as per specifications. m 13650.00
MORTH Chapter 12 (PWD SR2009-10/P.No. 175/25.2)

25.3 KSRRB 1100-3.1 : Bored / Cast-in-situ M-35 Grade R.C.C. piles excluding
reinforcement as per Drawing and Technical Specifications and removal of
excavated earth with all lifts and lead upto 1000 m complete as per
specifications. A. Pite diametre = 750 mm MORTH Specification m 4160.00
No. 1100 & 1700 (PWD SR2009-10/P.No. 175/25.3)
25.4 KSRRB 1100-3.2 : Bored / Cast-in-situ M-35 Grade R.C.C. piles excluding
reinforcement as per Drawing and Technical Specifications and removal of
excavated earth with all lifts and lead upto 1000 m complete as per
specifications. B. Pite diametre = 1000 mm MORTH Specification m 6820.00
No. 1100, 1600 & 1700 (PWD SR2009-10/P.No. 175/25.4)

25.5 KSRRB 1100-3.3: Bored / Cast-in-situ M-35 Grade R.C.C. piles excluding
reinforcement as per Drawing and Technical Specifications and removal of
excavated earth with all lifts and lead upto 1000 m complete as per
specifications. C. Pite diametre = 1200 mm MORTH Specification m 8750.00
No. 1100 & 1700 (PWD SR2009-10/P.No. 175/25.5)

KSRRB M1100 Driven cast-in-place R.C.C. Pile


25.6 KSRRB M1100-4.1 : Driving Cast-in-place vertical M-35, grade R.C.C. Pile
excluding reinforcement as per drawing and Technical Specifications
complete as per specifications. Pile diametre = 750 mm m 3460.00
MORT & H Specification No. 1100
& 1700 (PWD SR2009-10/P.No. 175/25.6)

25.7 KSRRB M1100-4.2 : Driving Cast-in-place vertical M-35, grade R.C.C. Pile
excluding reinforcement as per drawing and Technical Specifications
complete as per specifications. Pile diametre = 1000 mm m 5485.00
MORT & H Specification No.
1100 & 1700 (PWD SR2009-10/P.No. 175/25.7)

25.8 KSRRB M1100-4.3 : Driving Cast-in-place vertical M-35, grade R.C.C. Pile
excluding reinforcement as per drawing and Technical Specifications
complete as per specifications. Pile diametre = 1200 mm m 8020.00
MORT & H Specification No.
1100 & 1700 (PWD SR2009-10/P.No. 175/25.8)

25.9 KSRRB M1100-4.4 : Driven precast vertical M-35 Grade R.C.C. Piles
excluding Reinforcement as per Drawing and & Technical Specification
complete as per specifications. Pile diametre = 500 mm m 1585.00
MORT & H Specification No. 1100
& 1700 (PWD SR2009-10/P.No. 175/25.9)

25.10 KSRRB M1100-4.5 : Driven precast vertical M-35 Grade R.C.C. Piles
excluding Reinforcement as per Drawing and & Technical Specification
complete as per specifications. Pile diametre = 750 mm m 2640.00
MORT & H Specification No. 1100
& 1700 (PWD SR2009-10/P.No. 175/25.10)

25.11 KSRRB M1100-4.6 : Driven precast vertical M-35 Grade R.C.C. Piles
excluding Reinforcement as per Drawing and & Technical Specification
complete as per specifications. Pile diametre = 1000 mm m 4390.00
MORT & H Specification No.
1100 & 1700 (PWD SR2009-10/P.No. 175/25.11)

25.12 KSRRB M1100-4.7 : Driven precast vertical M-35 Grade R.C.C. Piles
excluding Reinforcement as per Drawing and & Technical Specification
complete as per specifications. Size of Pile = 300 mm x 300 mm m 1100.00
MORT & H Specification
No. 1100 & 1700 (PWD SR2009-10/P.No. 175/25.12)
25.13 KSRRB M1100-4.8 : Driven precast vertical M-35 Grade R.C.C. Piles
excluding Reinforcement as per Drawing and & Technical Specification
complete as per specifications. Size of Pile = 500 mm x 500 mm m 1750.00
MORT & H Specification
No. 1100 & 1700 (PWD SR2009-10/P.No. 176/25.13)

25.14 KSRRB M1100-4.9 : Driven precast vertical M-35 Grade R.C.C. Piles
excluding Reinforcement as per Drawing and & Technical Specification
complete as per specifications. Size of Pile = 750 mm x 750 mm m 3310.00
MORT & H Specification
No. 1100 & 1700 (PWD SR2009-10/P.No. 176/25.14)

25.15 KSRRB M1100-5 : Driven vertical steel Piles as per Drawing and &
Technical Specification complete as per specifications. Section of the pile
= H Section steel column 400 mm x 250 mm (ISHB Series) m 4590.00
MORT & H Specification No.
1100 & 1900 (PWD SR2009-10/P.No. 176/25.15)

25.16 KSRRB M1100-6 : Driven vertical steel Piles as per Drawing and &
Technical Specification complete as per specifications. Section of the pile
= H Section steel column 450 mm x 250 mm (ISHB Series) m 5240.00
MORT & H Specification No.
1100 & 1900 (PWD SR2009-10/P.No. 176/25.16)

KSRRB M1100- Pile Cap


25.18 KSRRB M1100- 8.1. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. A. RCC Grade M-20. Case-I : Using Concrete Mixer Cum 3730.00
MORTH Specification No. 1100, 1500 & 1700 (PWD SR2009-10/P.No.
176/25.18)

25.19 KSRRB M1100- 8.2. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. A. RCC Grade M-20. Case-II : Using Batching Plant, Transit Cum 3790.00
Mixer and Concrete Pump MORTH Specification No. 1100, 1500 & 1700
(PWD SR2009-10/P.No. 176/25.19)

25.20 KSRRB M1100- 9.1. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. B. RCC Grade M-25. Case-I : Using Concrete Mixer Cum 4080.00
MORTH Specification No. 1100, 1500 & 1700 (PWD SR2009-10/P.No.
176/25.20)

25.21 KSRRB M1100- 9.2. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. B. RCC Grade M-25. Case-II : Using Batching Plant, Transit Cum 4160.00
Mixer and Concrete Pump MORTH Specification No. 1100, 1500 & 1700
(PWD SR2009-10/P.No. 176/25.21)

25.22 KSRRB M1100- 10.1. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. C. RCC Grade M-30. Case-I : Using Concrete Mixer Cum 4125.00
MORTH Specification No. 1100, 1500 & 1700 (PWD SR2009-10/P.No.
176/25.22)
25.23 KSRRB M1100- 10.2. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. C. RCC Grade M-30. Case-II : Using Batching Plant, Transit Cum 4200.00
Mixer and Concrete Pump MORTH Specification No. 1100, 1500 & 1700
(PWD SR2009-10/P.No. 176/25.23)

25.24 KSRRB M1100- 11.1. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. D. RCC Grade M-35. Case-I : Using Concrete Mixer Cum 4220.00
MORTH Specification No. 1100, 1500 & 1700 (PWD SR2009-10/P.No.
176/25.24)

25.25 KSRRB M1100- 11.2. Cement Concrete for Reinforced Concrete in Pile
Cap as per Drawing and Technical Specifiction complete as per
specifications. D. RCC Grade M-35. Case-II : Using Batching Plant, Transit Cum 4300.00
Mixer and Concrete Pump MORTH Specification No. 1100, 1500 & 1700
(PWD SR2009-10/P.No. 176/25.25)

KSRRB M1100-Levelling course for Pile Cap


25.26 KSRRB M1100-12. Providing and laying of PCC M 15 Levelling course
100 mm thick below the Pile Cap Complete as per specifications MORTH
Specification No. 1100 & 1700 (PWD SR2009-10/P.No. 176/25.26) Cum 3270.00

KSRRB M1100- Supplying, Fitting and Placing un-coated HYSD bar/


MS Bar
25.27 KSRRB M1100-13. Supplying, Fitting and Placing un-coated TMT bar
Reinforcement in Foundation as per Drawing and Technical Specifications.
MORTH Specification No. 1600 (PWD SR2009-10/P.No. 177/25.27) Tonne 43550.00

25.28 KSRRB M1100-14. Supplying, Fitting and Placing un-coated Mild steel
Reinforcement in Foundation as per Drawing and Technical
Specifications.Complete as per specifications. MORTH Specification No. Tonne 43100.00
1600 (PWD SR2009-10/P.No. 177/25.28)

BRIDGES - WELL FOUNDATION


Sl. Description Rate
Unit
No. Rs. Ps.

KSRRB M1200-Temporary Island


26.1 KSRRB 1200-1.1 : Providing, and Constructing Temporary Island 16 m
diameter for Construction of well Foundation for 8m dia Well complete as
per specifications. MORT & H Specification No. 1200 (PWD SR2009- No 39450.00
10/P.No. 179/26.1)

26.2 KSRRB 1200-1.2: Providing, and Constructing Temporary Island 16 m


diameter for Construction of well Foundation for 8m dia Well complete as
per specifications. B. Assuming depth of water 4.0 m and high of island 4.5 No 258150.00
m MORT & H Specification No. 1200 (PWD SR2009-10/P.No.
179/26.2)
26.3 KSRRB 1200-1.3 : Providing, and Constructing Temporary Island 16 m
diameter for Construction of well Foundation for 8m dia Well complete as
per specifications. C. Providing and constructing one span service road to
reach island location from one pier location to another pier location- m 1750.00
Assuming span length 30m, width of service road 10 m & depth of water 1
m MORT & H Specification No. 1200 (PWD SR2009-10/P.No.
179/26.3)

KSRRB M1200- Providing and Laying Cutting Edge of Mild Steel


26.4 KSRRB 1200-2 : Providing, and Laying Cutting Edge of Mild Steel
weighing 40 kgper metre for Well Foundation complete as per Drawing
and technical Specification complete as per specifications. MORT & H Tonne 62220.00
Specification No. 1200 & 1900 (PWD SR2009-10/P.No. 179/26.4)

KSRRB M1200-Plain / Reinforced Cement Comcrete


26.5 KSRRB 1200-3.1 : Plain / Reinforced Cement Concrete, in Well
Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
179/26.5)

26.5.1 KSRRB 1200-3.1 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 i) RCC M-20 Grade Cum 4590.00
(PWD SR2009-10/P.No. 179/26.5.1)

26.5.2 KSRRB 1200-3.2 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 ii) RCC M-25 Grade Cum 4990.00
(PWD SR2009-10/P.No. 179/26.5.2)

26.5.3 KSRRB 1200-3.3 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 iii) RCC M-35 Grade Cum 5130.00
(PWD SR2009-10/P.No. 179/26.5.3)

26.5.4 KSRRB 1200-4.1 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 i) PCC M-15 Grade Cum 3830.00
(PWD SR2009-10/P.No. 179/26.5.4)

26.5.5 KSRRB 1200-4.2 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 ii) PCC M-20 Grade Cum 4140.00
(PWD SR2009-10/P.No. 179/26.5.5)

26.5.6 KSRRB 1200-4.3: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. MORT & H
Specification No. 1200, 1500 & 1700 iii) RCC M-20 Grade (PWD Cum 4210.00
SR2009-10/P.No. 179/26.5.6)

26.5.7 KSRRB 1200-4.4 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 iv) PCC M-25 Grade Cum 4510.00
(PWD SR2009-10/P.No. 179/26.5.7)

26.5.8 KSRRB 1200-4.5 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 v) RCC M-25 Grade Cum 4570.00
(PWD SR2009-10/P.No. 179/26.5.8)
26.5.9 KSRRB 1200-4.6 : Plain / Reinforced Cement Concrete, in Well
Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 vi) PCC M-30 Grade Cum 4550.00
(PWD SR2009-10/P.No. 179/26.5.9)

26.5.10 KSRRB 1200-4.7 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 vii) RCC M-30 Grade Cum 4600.00
(PWD SR2009-10/P.No. 179/26.5.10)

26.5.1 KSRRB 1200-4.8 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 viii) RCC M-35 Grade Cum 4700.00
(PWD SR2009-10/P.No. 179/26.5.1)

26.5.12 KSRRB 1200-4.9 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
MORT & H Specification No. 1200, 1500 & 1700 ix) RCC M-40 Grade - Cum 4720.00
Using Batching Plant, Transit Mixer and Concrete Pump (PWD
SR2009-10/P.No. 180/26.5.12)

26.6 KSRRB 1200-5.1 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
Concrete to be placed using termile pipe.C) Bottom Plug i) PCC Grade
M-20. Case - 1: Using Concrete Mixer. MORT & H Specification No. Cum 4320.00
1200, 1500 & 1700 (PWD SR2009-10/P.No. 180/26.6)

26.7 KSRRB 1200-5.2 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
Concrete to be placed using termile pipe. i) PCC Grade M-20. Case - 1:
Using Batching Plant. Transit Mixer and Crane / Concrete Pump Cum 4070.00
MORT & H Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
180/26.7)

26.8 KSRRB 1200-6.1: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. ii) PCC Grade M-25. Case - 1: Using Concrete Cum 4520.00
Mixer MORT & H Specification No. 1200, 1500 & 1700 (PWD SR2009-
10/P.No. 180/26.8)

26.9 KSRRB 1200-6.2: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. ii) PCC Grade M-25. Case - 1: Using Batching
Plant. Transit Mixer and Crane / Concrete Pump MORT & H Cum 4270.00
Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No. 180/26.9)

26.10 KSRRB 1200-7.1: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iii) PCC Grade M-30. Case - 1: Using Cum 5120.00
Concrete Mixer MORT & H Specification No. 1200, 1500 & 1700 (PWD
SR2009-10/P.No. 180/26.10)

26.11 KSRRB 1200-7.2: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iii) PCC Grade M-30. Case - 1: Using
Batching Plant. Transit Mixer and Crane / ConcretePump MORT & H Cum 4310.00
Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No. 180/26.11)
26.12 KSRRB 1200-8.1: Plain / Reinforced Cement Concrete, in Well Foundation
Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iv) PCC Grade M-35. Case - 1: Cum 5220.00
Using Concrete Mixer MORT & H Specification No. 1200, 1500 & 1700
(PWD SR2009-10/P.No. 180/26.12)

26.13 KSRRB 1200-8.2: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iv) PCC Grade M-35. Case - II: Using
Batching Plant, Transit Mixer and Crane / Concrete Pump MORT & H Cum 4390.00
Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No. 180/26.13)

D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well


Foundation
26.14 KSRRB M1200-9.1. (i) Grade M-20 PCC Same as in bottom plug concrete,
excluding cost of forming sump, protective bunds , chiselling etc., MORTH
Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No. 180/26.14) Cum 4130.00

26.15 D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well


Foundation MORTH Specification No. 1200, 1500 & 1700.

26.15.1 KSRRB M1200-9.2. D. Intermediate Plug - Plain / Reinforced Cement


Concrete, in Well Foundation MORTH Specification No. 1200, 1500 & Cum 4320.00
1700. ii) Grade M-25 PCC (PWD SR2009-10/P.No. 181/26.15.1)

26.15.2 KSRRB M1200-9.3. D. Intermediate Plug - Plain / Reinforced Cement


Concrete, in Well Foundation MORTH Specification No. 1200, 1500 & Cum 5120.00
1700. iii) Grade M-30 PCC (PWD SR2009-10/P.No. 181/26.15.2)

26.16 E. Top Plug


KSRRB M1200-10.1. i) Grade M-15 PCC MORTH Specification No. Cum 3480.00
1200, 1500 & 1700 (PWD SR2009-10/P.No. 181/26.16)

26.17 KSRRB M1200-10.2. ii) Grade M-20 PCC MORTH Specification No. 1200,
Cum 3770.00
1500 & 1700 (PWD SR2009-10/P.No. 181/26.17)

26.18 KSRRB M1200-10.3. iii) Grade M-25 PCC Same as item 2100-11.9
excluding formwork MORTH Specification No. 1200, 1500 & 1700 (PWD Cum 4100.00
SR2009-10/P.No. 181/26.18)

26.19 KSRRB M1200-10.4. iv) Grade M-30 PCC Same as item 2100-11.9
excluding formwork MORTH Specification No. 1200, 1500 & 1700 (PWD Cum 4130.00
SR2009-10/P.No. 181/26.19)

26.20 KSRRB M1200-11.1. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification F. Well
cap. i) RCC Grade M-20 Case -1: Using Concrete Mixer MORTH Cum 4540.00
Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No. 181/26.20)

26.21 KSRRB M1200-11.2. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification
Case -II: Using Batching Plant, Transit Mixer and Crane / Concrete Pump Cum 3770.00
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
181/26.21)
26.22 KSRRB M1200-11.3. Plain / Reinforced Cement Concrete, in Well
Foundation Complete as per Drawing and Technical Specification
i) RCC Grade M-20 Case -1: Using Concrete Mixer Cum 4310.00
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
181/26.22)

26.23 KSRRB M1200-11.4. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification
ii) RCC Grade M-25 Case -1: Using Concrete Mixer Cum 4160.00
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
181/26.23)

26.24 KSRRB M1200-11.5. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification
iii) RCC Grade M-30 Case -1: Using Concrete Mixer Cum 4340.00
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
181/26.24)

26.25 KSRRB M1200-11.6. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification
Case -II: Using Batching Plant, Transit Mixer and Crane / Concrete Cum 4160.00
Pump MORTH Specification No. 1200, 1500 & 1700
(PWD SR2009-10/P.No. 181/26.25)

26.26 KSRRB M1200-11.7. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification iv) RCC
Grade M-35. Case -I: Using Concrete Mixer MORTH Cum 4400.00
Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No. 181/26.26)

26.27 KSRRB M1200-11.8. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification
Case -II: Using Batching Plant, Transit Mixer and Crane / Concrete Pump Cum 4250.00
MORTH Specification No. 1200, 1500 & 1700 (PWD
SR2009-10/P.No. 182/26.27)

26.28 KSRRB M1200-12. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification (v)
RCC Grade M-40. Using Batching Plant, Transit Mixer and Concrete Pump Cum 4440.00
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2009-10/P.No.
182/26.28)

KSRRB M1200- Sinking of well in sandy soil


26.29 KSRRB 1200-13.1 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 1150.00
bed level complete as per specifications. (i) Depth below bed level upto
3.0 m, Rate of sinking = 0.50 m per hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 182/26.29)

26.30 KSRRB 1200-13.2 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 1580.00
bed level complete as per specifications. (ii) Beyond 3 m upto 10 m,
depth, Rate of sinking = 0.33 m per hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 182/26.30)
26.34 KSRRB 1200-14.1 : Sinking of 7 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. A. Sandy Soil, Diameter of well m 1650.00
= 7m (i) Depth below bed level upto 3.0 m, Rate of sinking = 0.30 m per
hour. MORT & H Specification No. Section1200 (PWD SR2009-10/P.No.
182/26.34)

26.35 KSRRB 1200-14.2 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2160.00
bed level complete as per specifications. (ii) Beyond 3 m upto 10 m,
depth, Rate of sinking = 0.22 m per hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 182/26.35)

26.39 KSRRB 1200-15.1 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. (i) Depth below bed level upto m 2010.00
3.0 m. Rate of sinking at 0.25 m per hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 182/26.39)

26.40 KSRRB 1200-15.2 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2450.00
bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth.
Rate of sinking at 0.20 m per hour. MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 182/26.40)

26.44 KSRRB 1200-16.1 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2060.00
bed level complete as per specifications. (i) Depth below bed level upto
3.0 m. Rate of sinking at 0.25 m per hour. MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 182/26.44)

26.45 KSRRB 1200-16.2 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2700.00
bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.18 m per hour. MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.45)

26.49 KSRRB 1200-17.1 : Sinking of 10 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. . MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.49)
26.49.1 KSRRB 1200-17.1 : Sinking of 10 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 2400.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.20 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.49.1)

26.49.2 KSRRB 1200-17.1 : Sinking of 10 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 2870.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.17 m / hour MORT & H Specification No. Section1200
(PWD SR2009-10/P.No. 183/26.49.2)

26.53 KSRRB 1200-18.1 : Sinking of 11 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 5310.00
bed level complete as per specifications.i) Depth below bed level upto 3.0
m. Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.53)

26.54 KSRRB 1200-18.2 : Sinking of 11 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4820.00
bed level complete as per specifications.ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.13 m / hour MORT & H Specification No. Section1200
(PWD SR2009-10/P.No. 183/26.54)

26.58 KSRRB 1200-19.1 : Sinking of 12 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 11340.00
bed level complete as per specifications.i) Depth below bed level upto 3.0
m. Rate of sinking at 0.05 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.58)

26.59 KSRRB 1200-19.2 : Sinking of 12 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications.i) Beyond 3 m upto 10 m depth. m 13130.00
Rate of sinking at 0.038 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.59)

26.63 KSRRB 1200-20.1 : Sinking of Twin D type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level
complete as per specifications. Overall length = 12 m, Overall width = 6 m m 2540.00
i) Depth from bed level upto 3.0 m. Rate of sinking = 0.18 m / hour
MORT & H Specification No. Section1200 (PWD SR2009-10/P.No.
183/26.63)
26.64 KSRRB 1200-20.2 : Sinking of Twin D type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level
complete as per specifications. Overall length = 12 m, Overall width = 6 m m 2460.00
ii) Beyond 3 m upto 10 m depth. Rate of sinking at 0.17 m / hour MORT
& H Specification No. Section1200 (PWD SR2009-10/P.No. 183/26.64)

26.68 KSRRB 1200-21.1 : Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 1580.00
bed level complete as per specifications. i) Depth below bed level upto
3.00 m, rate of sinking at 0.33 m per hour. MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 183/26.64)

26.69 KSRRB 1200-21.2 : Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 3780.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth,
rate of sinking at 0.17 m per hour. MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.69)

26.73 KSRRB 1200-212.1 : Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2160.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.22 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.73)

26.74 KSRRB 1200-22.1 : Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 3870.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 depth.
Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.74)

26.78 KSRRB 1200-23.1 : Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2640.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.18 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.78)

26.79 KSRRB 1200-23.2 : Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4140.00
bed level complete as per specifications. ii) Beyond 3 m upto10 m depth.
Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.79)
26.83 KSRRB 1200-24.1 : Sinking of 9 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2810.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.83)

26.84 KSRRB 1200-24.2 : Sinking of 9 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4450.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.84)

26.88 KSRRB 1200-25.1 : Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 3250.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.18 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.88)

26.89 KSRRB 1200-25.2 : Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4600.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184/26.89)

26.93 KSRRB 1200-26.1 : Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 5380.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.10 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 184-185/26.93)

26.94 KSRRB 1200-26.2 : Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 9650.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.08 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 185/26.94)

26.98 KSRRB 1200-27.1 : Sinking of 12 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 12980.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.04 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 185/26.98)
26.99 KSRRB 1200-27.2 : Sinking of 12 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 22700.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.03 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 185/26.99)

26.103 KSRRB 1200-28.1 : Sinking of Twin D Type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level m 3050.00
complete as per specifications. i) Depth below bed level upto 3.0 m. Rate
of sinking = 0.16 m / hour MORT & H Specification No. Section1200
(PWD SR2009-10/P.No. 185/26.103)

26.104 KSRRB 1200-28.2 : Sinking of Twin D Type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level m 5090.00
complete as per specifications. ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.15 m / hour MORT & H Specification No. Section1200
(PWD SR2009-10/P.No. 185/26.104)

26.107 KSRRB 1200-29 : Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 6920.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m depth. Rate of sinking = 0.25 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 185/26.107)

26.108 KSRRB 1200-30 : Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 5390.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.22 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 185/26.108)

26.109 KSRRB 1200-31 : Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 5980.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.22 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 185/26.109)

26.110 KSRRB 1200-32 : Sinking of 9 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 6950.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 186/26.110)
26.111 KSRRB 1200-33 : Sinking of 10 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 7620.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.14 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 186/26.111)

26.112 KSRRB 1200-34 : Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 16900.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.06 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 186/26.112)

26.113 KSRRB 1200-35 : Sinking of 12 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 37660.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.025 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 186/26.113)

26.114 KSRRB 1200-36 : Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level m 8470.00
complete as per specifications. Depth in soft rock strata upto 3 m . Rate of
sinking = 0.12 m / hour MORT & H Specification No. Section1200
(PWD SR2009-10/P.No. 186/26.114)

KSRRB M1200 - Hard Rock


26.115 KSRRB 1200-37 : Sinking of 6 m external diameter Well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 6940.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 186/26.115)

26.116 KSRRB 1200-38 : Sinking of 7 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 8670.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 186/26.116)

26.117 KSRRB 1200-39 : Sinking of 8 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 9000.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 187/26.117)
26.118 KSRRB 1200-40 : Sinking of 9 m external diameter Well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 10370.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 187/26.118)

26.119 KSRRB 1200-41 : Sinking of 10 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 11420.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.12 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 187/26.119)

26.120 KSRRB 1200-42 : Sinking of 11 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 25270.00
bed level complete as per specifications.Depth in hard rock strata upto 3
m . Rate of sinking = 0.05 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 187/26.120)

26.121 KSRRB 1200-43 : Sinking of 12 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 54800.00
bed level complete as per specifications.Depth in hard rock strata upto 3
m . Rate of sinking = 0.020 m / hour MORT & H Specification No.
Section1200 (PWD SR2009-10/P.No. 187/26.121)

26.122 KSRRB 1200-44 : Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level m 11900.00
complete as per specifications.Depth in hard rock strata upto 3 m . Rate of
sinking = 0.10 m / hour MORT & H Specification No. Section1200
(PWD SR2009-10/P.No. 187/26.122)

26.123 KSRRB 1200-45 : Penumatic Sinking of Wells with equipment of approved


design, drawing and specifications worked by competent and trained
personnel and comprising of decompression chambers, reducers, two air
locks separately for men and plant & materials, arrangment for supply of
fresh air to working chambers, check valves, exhaust valves, shafts made
from steel plates of riveted construction not less than 6 mm thick to
withstand an air pressure of 0.50 Mpa, controlled blasting of hard rock
where required, staircases and 1 m wide landing platforms with railing, Cum 47960.00
arrangement for compression and decompression, electric lighting of 50 V
maximum, proper rooms for rest and medical examinations and
compliance with safety precautions as per IS: 4138, all as per clause
1200.7.6 of MORT & H Specification No. Section1200 (PWD SR2009-
10/P.No. 187-188/26.123)

26.124 KSRRB 1200-46 : Sand filling in wells Complete as per drawing and
technical specifications MORT & H Specification No. Section1207 (PWD Cum 980.00
SR2009-10/P.No. 188/26.124)
26.125 KSRRB 1200-47 : Providing Steel liner 10 mm thick for curbs and 6 mm
thick for seining of wells including fabricating and setting out as per
detailed drawing Complete as per specifications MORT & H Specification Tonne 57500.00
No. Section1207 (PWD SR2009-10/P.No. 188/26.125)

KSRRB M1200-Reinforced Cement concrete for welll curb


26.126 KSRRB M1200-48.1. Construction of cement concrete kerb with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm
projection beyond kerb stone, kerb stone laid with kerb lying machine, m 255.00
foundation concrete laid manually, all complete as per clause 400.8
complete as per specifications. A. Using Concrete Mixer. MORTH
Specification No.408. (PWD SR2009-10/P.No. 188/26.126)

26.127 KSRRB M1200-48.2. Construction of cement concrete kerb with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm
projection beyond kerb stone, kerb stone laid with kerb lying machine,
foundation concrete laid manually, all complete as per clause 400.8 m 205.00
complete as per specifications. B. Using Concrete Batching and Mixing
Plant. MORTH Specification No.408. (PWD SR2009-10/P.No. 188/26.127)

26.128 KSRRB M1200-49.1. Cast-in-Situ Cement Concrete M 20 kerb with


Channel. Construction of cement concrete kerb with channel with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, kerb channel laid with kerb
lying machine, foundation concrete laid manually, all complete as per m 470.00
clause 400.8 complete as per specifications. A. Using Concrete Mixer
Plant. MORTH Specification No.408. (PWD SR2009-10/P.No. 188/26.128)

26.129 KSRRB M1200-49.2. Cast-in-Situ Cement Concrete M 20 kerb with


Channel. Construction of cement concrete kerb with channel with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, kerb channel laid with kerb
lying machine, foundation concrete laid manually, all complete as per m 395.00
clause 400.8 complete as per specifications. B. Using Concrete Batching
and Mixing Plant. MORTH Specification No.408. (PWD SR2009-10/P.No.
188/26.129)

BRIDGES - OPEN FOUNDATIONS


KSRRB M2100 - Excavation in Ordinary Soil
27.1 kSRRB M2100 - 1.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 60.00
approved material complete as per specifications. 1. Ordinary Soil - A.
Manual Means (i) Depth upto 3 m. Morth specification No. 304
(PWD SR2009-10/P.No. 191/27.1)

27.2 kSRRB M2100 - 1.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 78.00
approved material complete as per specifications. 1. Ordinary Soil - A.
Manual Means (ii) 3 m to 6m depth Morth specification No. 304
(PWD SR2009-10/P.No. 191/27.2)
27.3 kSRRB M2100 - 1.3. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 104.00
approved material complete as per specifications. 1. Ordinary Soil - A.
Manual Means (iii) Above 6m depth Morth specification No. 304
(PWD SR2009-10/P.No. 191/27.3)

27.3.1 kSRRB M2100. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and backfilling with approved material Cum 86.00
complete as per specifications. 1. Hard Soil Up to 3 m depth. Morth
specification No. 304 (PWD SR2009-10/P.No. 191/27.3.1)

27.3.2 kSRRB M2100. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and backfilling with approved material Cum 111.00
complete as per specifications. 1. Hard Soil Up to 3 m to 6 m depth. Morth
specification No. 304 (PWD SR2009-10/P.No. 191/27.3.2)

27.3.3 kSRRB M2100. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and backfilling with approved material Cum 138.00
complete as per specifications. 1. Hard Soil above 6 m depth. Morth
specification No. 304 (PWD SR2009-10/P.No. 191/27.3.3)

27.4 kSRRB M2100. 2.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 36.00
approved material complete as per specifications. B. Mechanical Means.
(i) Depth upto 3 m. Morth specification No. 304 (PWD SR2009-10/P.No.
191/27.4)

27.5 kSRRB M2100. 2.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 41.00
approved material complete as per specifications. B. Mechanical Means.
(ii) Depth 3 m to 6 m . Morth specification No. 304 (PWD SR2009-
10/P.No. 191/27.5)

27.6 kSRRB M2100. 2.3. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 50.00
approved material complete as per specifications. B. Mechanical Means.
(iii) Depth above 6 m . Morth specification No. 304 (PWD SR2009-
10/P.No. 191/27.6)

KSRRB M2100 - Excavation on Ordinary Rock with blasting.


27.7 kSRRB M2100. 3.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 87.00
approved material complete as per specifications. "II. Ordinary rock - (not
requiring blasting) A. Manual Means. Depth above 3 m .
Morth specification No. 304 (PWD SR2009-10/P.No. 191/27.7)

27.8 kSRRB M2100. 3.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 46.00
approved material complete as per specifications. "II. Ordinary rock - (not
requiring blasting) B. Mechanical Means. Depth above 3 m .
Morth specification No. 304 (PWD SR2009-10/P.No. 191/27.8)

KSRRB M2100 - Excavation on Hard Rock with blasting.


27.9 kSRRB M2100. 4.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 238.00
approved material complete as per specifications. "III. Hard rock -
(requiring blasting) A. Manual Means. Morth specification No. 304 (PWD
SR2009-10/P.No. 191/27.9)

KSRRB M2100 - Excavation on Hard Rock without blasting.


27.10 kSRRB M2100. 4.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 272.00
approved material complete as per specifications. "III. Hard rock -
( blasting prohibited) A. Mechanical Means. Morth specification No. 304
(PWD SR2009-10/P.No. 192/27.10)

KSRRB M2100 - Excavation in Marshy Soil


27.11 kSRRB M2100. 5. Excavation in Marshy Soil upto 3m depth for
foundations of structures as per drawing and technical specifications,
including removing the excavated stuff to a lead of 15m, including
dewatering, shoring and shuttering, refilling trenches in 250mm layers, Cum 294.00
wherever necessary watering and ramming, including cost of all materials,
labour complete as per specifications. Morth Chapter -12 (PWD SR2009-
10/P.No. 192/27.11)

27.12 kSRRB M2100.5.1. Earth work in Excavation for foundations of structures


as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
Cum 226.00
approved material complete as per specifications. "V. Marshy Soil -
A.Manual means Upto 3 m depth. Morth Specification No. 304. (PWD
SR2009-10/P.No. 192/27.12)

27.13 kSRRB M2100.5.2. Earth work in Excavation for foundations of structures


as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 68.00
approved material complete as per specifications. "V. Marshy Soil -
A.Mechanical means Upto 3 m depth. Morth Specification No. 304. (PWD
SR2009-10/P.No. 192/27.13)
KSRRB M2100 Filling the foundations

27.14 kSRRB M2100.6. Filling the foundations trenches using approved sand as
per drawing and technical specifications in 250mm layers, Wherever
necessary watering and ramming. including cost of all materials, labour Cum 1110.00
complete as per specifications. "V. Marshy Soil - A.Mechanical means
Upto 3 m depth. Morth Chapter 12 (PWD SR2009-10/P.No. 192/27.14)

KSRRB M2100 Back Filling of abutments using wing wall & Returns

27.15 KSRRB M2100-7. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and Back Filling with approved material Cum 150.00
complete as per specifications. VI. Backfilling in Marshy Foundation Pits."
MORTH Specification No.304. (PWD SR2009-
10/P.No. 192/27.15)

27.16 KSRRB M2100-8. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and Back Filling with approved material
complete as per specifications. VI. Backfilling in Marshy Foundation Pits." Cum 3830.00
MORTH Specification No.304. (PWD SR2009-
10/P.No. 192/27.16) Filling Annular Space Around Footing in Rock
Lean cement concrete 1:3:6 nominal mix

27.17 KSRRB M2100-9. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and Back Filling with approved material
complete as per specifications. VI. Backfilling in Marshy Foundation Pits." Cum 985.00
MORTH Specification No.304. (PWD SR2009-
10/P.No. 192/27.17) Sand Filling in foundation Trenches as per
Drawing & Technical Specification No. 304.

KSRRB M2100 PCC 1


27.18 KSRRB M2100-10. Plain cement 1:3:6 nominal mix in foundation with
crushed stone aggregates 40 mm nominal size mechanically mixed,
placed in foundation and compacted by vibration including curing for 14 Cum 3045.00
days complete as per specifications MORTH Specification No. 2100.(PWD
SR2009-10/P.No. 193/27.18)

KSRRB M2100 Brick masonry work


27.19 KSRRB M2100-11. Brick masonry work in Cement Mortar 1:3 in
Foundation complete excluding Pointing and Plastering as per Drawing
and Technical Specifications MORTH Specification No. 1300.(PWD Cum 3720.00
SR2009-10/P.No. 193/27.19)

27.20 KSRRB M2100-11.1. Brick masonry work in Cement Mortar 1:3 in


Foundation complete excluding Pointing and Plastering as per Drawing
and Technical Specifications MORTH Specification No. 1300.(PWD Cum 3080.00
SR2009-10/P.No. 193/27.20) Cement Mortar 1:3 (1 cement : 3 sand)

KSRRB M2100 Stone Masonry Work


27.22 KSRRB M2100-12.1. Stone masonry work in Cement Mortar 1:3 in
Foundation complete as per Drawing and Technical Specifications A.
Square Coursed Rubbil Masonry (first sort) MORTH Specification No. Cum 2160.00
1405.4.(PWD SR2009-10/P.No. 193/27.22)

27.23 KSRRB M2100-12.2. Stone masonry work in Cement Mortar 1:3 in


Foundation complete as per Drawing and Technical Specifications B.
Random Rubbil Masonry (coursed / uncoursed) MORTH Specification No. Cum 2150.00
1405.4.(PWD SR2009-10/P.No. 193/27.23)

KSRRB M2100 Plain / R.C.C in open foundation


27.24 KSRRB M2100-13. Plain / Reinforced Cement Concrete in open
foundation complete as per Drawing and Technical Specifications A. PCC
Grade M-15. MORTH Specification No. 1500, 1700 & 2100.(PWD Cum 3620.00
SR2009-10/P.No. 193/27.24)

27.25 KSRRB M2100-14. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications B. PCC
Grade M-20". MORTH Specification No. 1500, 1700 & 2100.(PWD Cum 3920.00
SR2009-10/P.No. 193/27.25)

27.26 KSRRB M2100-15.1. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications C. RCC
Grade M-20". Case-1: Using Concrete Mixer" MORTH Specification No. Cum 3980.00
1500, 1700 & 2100.(PWD SR2009-10/P.No. 193/27.26)

27.26.1 KSRRB M2100-15.1. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications C. RCC
Grade M-20". Case-1: Using Concrete Mixer" MORTH Specification No. Cum 3980.00
1500, 1700 & 2100.(PWD SR2009-10/P.No. 193/27.26.1) For RCC raft
slab of all size.

27.26.2 KSRRB M2100-15.1. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications C. RCC
Grade M-20". Case-1: Using Concrete Mixer" MORTH Specification No. Cum 4030.00
1500, 1700 & 2100.(PWD SR2009-10/P.No. 193/27.26.2) For RCC raft
beam of all size.

27.27 KSRRB M2100-15.2. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications Case-II:
With Batching Plant, Transit Mixer and Concrete Pump, Grade M20 Cum 3710.00
MORTH Specification No. 1500, 1700 & 2100.(PWD SR2009-10/P.No.
193/27.27)

27.28 KSRRB M2100-16.1. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications D. PCC
Grade M-25". Case-1: Using Concrete Mixer" MORTH Specification No. Cum 4250.00
1500, 1700 & 2100.(PWD SR2009-10/P.No. 193/27.28)

27.29 KSRRB M2100-16.2. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications D. PCC
Grade M-25". Case-II: With Batching Plant, Transit Mixer and Concrete Cum 4090.00
Pum. MORTH Specification No. 1500, 1700 & 2100.(PWD SR2009-
10/P.No. 193/27.29)
27.30 KSRRB M2100-17.1. Plain / Reinforced Cement Concrete in open
foundation complete as per Drawing and Technical Specifications
E. RCC Grade M-25". Case-I: Using Concrete Mixer.MORTH Cum 4310.00
Specification No. 1500, 1700 & 2100.(PWD SR2009-10/P.No. 194/27.30)

27.31 KSRRB M2100-17.2. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
E. RCC Grade M-25". Case-II: With Batching Plant, Transit Mixer Cum 4150.00
and Concrete Pump. MORTH Specification No. 1500, 1700 & 2100.(PWD
SR2009-10/P.No. 194/27.31)

27.32 KSRRB M2100-18.1. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
F. PCC Grade M-30". Case-I: Using Concrete Mixer. MORTH Cum 4280.00
Specification No. 1500, 1700 & 2100.(PWD SR2009-10/P.No. 194/27.32)

27.33 KSRRB M2100-18.2. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
F. PCC Grade M-30". Case-II: With Batching Plant, Transit Mixer and Cum 4110.00
Concrete Pump. MORTH Specification No. 1500, 1700 & 2100.(PWD
SR2009-10/P.No. 194/27.33)

27.34 KSRRB M2100-19.1.. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
G. RCC Grade M-30". Case-I: Using Concrete Mixer. MORTH Cum 4320.00
Specification No. 1500, 1700 & 2100.(PWD SR2009-10/P.No. 194/27.34)

27.35 KSRRB M2100-19.2.. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
G. RCC Grade M-30". Case-II: With Batching Plant, Transit Mixer Cum 4150.00
and Concrete Pump. MORTH Specification No. 1500, 1700 & 2100.(PWD
SR2009-10/P.No. 194/27.35)

27.36 KSRRB M2100-20.1. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
H. RCC Grade M-35". Case-I: Using Concrete Mixer. MORTH Cum 4400.00
Specification No. 1500, 1700 & 2100.(PWD SR2009-10/P.No. 194/27.36)

27.37 KSRRB M2100-20.2. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications
H. RCC Grade M-35".Case-II: With Batching Plant, Transit Mixer and Cum 4230.00
Concrete Pump. MORTH Specification No. 1500, 1700 & 2100.(PWD
SR2009-10/P.No. 194/27.37)

BRIDGES - SUB - STRUCTURE


KSRRB M2200-1. Brick masonry in Substructure
28.1 KSRRB M2200-1. Brick masonry work in 1:3 in Substructure complete
excluding pointing and plastering, as per drawing and Technical
Cum 6320.00
specifications complete MORTH Specification No. 1300 & 2200 as per
specifications (PWD SR2009-10/P.No. 196/28.1)

28.2
KSRRB M2200-2. Pointing with cement mortar (1:3) on Brick work in
Substructure Technical specifications complete MORTH Specification No. Sqm 29.00
1300 & 2200 as per specifications (PWD SR2009-10/P.No. 196/28.2)
28.3 KSRRB M2200-3. Plastering with cement mortar (1:3) on Brick work in
Sub-structure as per Technical specifications complete MORTH
Sqm 77.00
Specification No. 1300 & 2200 as per specifications (PWD SR2009-
10/P.No. 196/28.3)

KSRRB M2200 - Stone masonry in Substructure


28.4 KSRRB M2200-4.1. Stone masonry work in cement mortar 1:3 for Sub-
structure as per specifications A. Random Rubble Masonry (Uncoursed)
Cum 2140.00
MORTH Specification No. 1400 & 2200 as per specifications (PWD
SR2009-10/P.No. 196/28.4)

28.5 KSRRB M2200-4.2. Stone masonry work in cement mortar 1:3 for Sub-
structure as per specifications B. Coursed Rubble Masonry (first sort)
Cum 2150.00
MORTH Specification No. 1400 & 2200 as per specifications (PWD
SR2009-10/P.No. 196/28.5)

28.6 KSRRB M2200-4.3. Stone masonry work in cement mortar 1:3 for Sub-
structure as per specifications C. Ashlar Masonry (first sort) Plain ashlar
Cum 2640.00
MORTH Specification No. 1400 & 2200 as per specifications (PWD
SR2009-10/P.No. 196/28.6)

KSRRB M2200 - PCC/RCC


28.7 KSRRB M2200 -Plain / Reinforced cement concrete in Sub-structure
complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum
(PWD SR2009-10/P.No. 196/28.7)

28.7.1
KSRRB M2200-5.1. Plain / Reinforced cement concrete in Sub-structure
complete as per drawing and Technical Specifictions complete as per
Cum 3820.00
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum a)
PCC Grade M -15, upto 5 m height. (PWD SR2009-10/P.No. 196/28.7.1)

28.7.2
KSRRB M2200-5.2. Plain / Reinforced cement concrete in Sub-structure
complete as per drawing and Technical Specifictions complete as per
Cum 4140.00
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum b)
PCC Grade M - 20, upto 5 m height. (PWD SR2009-10/P.No. 196/28.7.2)

28.7.3 KSRRB M2200-5.3. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum c) Cum 4500.00
PCC Grade M - 25, i) upto 5 m height. (PWD SR2009-10/P.No.
196/28.7.3)

28.7.4 KSRRB M2200-5.4. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum Cum 4660.00
PCC Grade M - 25, ii) For height above 5 m and upto 10 m. (PWD
SR2009-10/P.No. 196/28.7.4)

28.7.5 KSRRB M2200-5.5. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum Cum 4870.00
PCC Grade M - 25, iii) For height above 10 m. (PWD SR2009-10/P.No.
196/28.7.5)

28.7.6 KSRRB M2200-5.6. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum d) Cum 4530.00
PCC Grade M - 30, i) upto 5 m height. (PWD SR2009-10/P.No.
196/28.7.6)
28.7.7 KSRRB M2200-5.7. Plain / Reinforced cement concrete in Sub-structure
complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum d) Cum 4700.00
PCC Grade M - 30, ii) For height above 5 m and upto 10 m. (PWD
SR2009-10/P.No. 196/28.7.7)

28.7.8 KSRRB M2200-5.8. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum d) Cum 4920.00
PCC Grade M - 30, iii) For height above 10 m. (PWD SR2009-10/P.No.
197/28.7.8)

28.7.9 KSRRB M2200-5.9. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum e) Cum 4200.00
RCC Grade M - 20, i) Upto 5 m height. (PWD SR2009-10/P.No.
197/28.7.9)

28.7.10 KSRRB M2200-5.10. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum e) Cum 4380.00
RCC Grade M - 20, ii) For height upto 10 m. (PWD SR2009-10/P.No.
197/28.7.10)

28.7.11 KSRRB M2200-5.11. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum e) Cum 4550.00
RCC Grade M - 20, ii) For height above 10 m. (PWD SR2009-10/P.No.
197/28.7.11)

28.7.12 KSRRB M2200-5.12. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum f) Cum 4570.00
RCC Grade M - 25, i) upto 5 m height. (PWD SR2009-10/P.No.
197/28.7.12)

28.7.13 KSRRB M2200-5.13. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum f) Cum 4720.00
RCC Grade M - 25, ii) For height upto 10 m. (PWD SR2009-10/P.No.
197/28.7.13)

28.7.14 KSRRB M2200-5.14. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum f) Cum 4950.00
RCC Grade M - 25, iii) For height above 10 m. (PWD SR2009-10/P.No.
197/28.7.14)

28.7.15 KSRRB M2200-5.15. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum g) Cum 4590.00
RCC Grade M - 30, i) upto 5 m height. (PWD SR2009-10/P.No.
197/28.7.13)

28.7.16 KSRRB M2200-5.16. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum g) Cum 4720.00
RCC Grade M - 30, ii) For height upto 10 m. (PWD SR2009-10/P.No.
197/28.7.13)
28.7.17 KSRRB M2200-5.17. Plain / Reinforced cement concrete in Sub-structure
complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum g) Cum 4900.00
RCC Grade M - 30, iii) For height above 10 m. (PWD SR2009-10/P.No.
197/28.7.17)

28.7.18 KSRRB M2200-5.18. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum h) Cum 4690.00
RCC Grade M - 35, ii) upto 5 m height. (PWD SR2009-10/P.No.
197/28.7.18)

28.7.19 KSRRB M2200-5.19. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum h) Cum 4800.00
RCC Grade M - 35, ii) For height upto 10 m. (PWD SR2009-10/P.No.
197/28.7.19)

28.7.20 KSRRB M2200-5.20. Plain / Reinforced cement concrete in Sub-structure


complete as per drawing and Technical Specifictions complete as per
specifications MORTH Specification No.1500, 1700 & 2200 Unit = Cum h) Cum 4950.00
RCC Grade M - 35, iii) For height upto 10 m. (PWD SR2009-10/P.No.
197/28.7.20)

KSRRB M2200-TMT/MS Bar Reinforcement


28.8 KSRRB M2200-6 Supplying, fitting and placing TMT Bar Reinforcement in
sub-structure complete as per drawing and Technical Specifications
Tonne 43640.00
complete as per specifications MORTH Specification No. 1600 & 2200.
(PWD SR2009-10/P.No. 197/28.8)

28.9 KSRRB M2200-7 Supplying, fitting and placing TMT Bar Reinforcement
complete in sub-structure as per drawing and Technical Specifications
Tonne 42810.00
complete as per specifications MORTH Specification No. 1600 & 2200.
(PWD SR2009-10/P.No. 197/28.9)

KSRRB M2200- Providing Weep Holes


28.10 KSRRB M2200-8. Providing Weep Holes in Brick masonry / Plain /
Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC
pipe, extending through the full width of the structure with slope of 1V:20H
mtr 169.00
towards drawing foce. Complete as per drawing and Technical
Specifications complete as per specifications MORTH Specification No.
2706 & 2200 (PWD SR2009-10/P.No. 197/28.10)

28.11 KSRRB M2200-8.1. Back filling behind abutment, wing wall and return wall
Complete as per drawing and Technical Specifications complete as per
Cum 273.00
specifications. A. Granular material MORTH Specification No. 710.14 of
IRC:78 & 2200 (PWD SR2009-10/P.No. 197/28.11)

28.12 KSRRB M2200-8.2. Back filling behind abutment, wing wall and return wall
Complete as per drawing and Technical Specifications complete as per
Cum 1065.00
specifications. B. Sandy material MORTH Specification No. 710.14 of
IRC:78 & 2200 (PWD SR2009-10/P.No. 197/28.12)

KSRRB M2200- Filter Media


28.13 KSRRB M2200-9. Providing and laying of filter media with granular
materials/stone crushed aggregates satisfying the requirements laid down
in clause 2500.4.2.2 of MORTH Specifications to a thickness of not less
than 600 mm with smaller size towards the soil and bigger size towards
the wall and provided over the entire surface behind abutment, wing wall Cum 855.00
and return wall to the full height compacted to a firm condition complete as
per drawing and Technical specifications. Complete as per specifications
MORTH Specification No. 710.14 of IRC:78 & 2200 (PWD SR2009-
10/P.No. 197-198/28.13)

KSRRB M2200-Bearings
28.14 KSRRB M2200-10. Supplying, fitting and fixing in position true to line and
level cast steel rocker Bearing conforming to IRC: 83(Pt.-1)section IX and
clause 2000.3 of MORHT Specifications complete including all accessories
Tonne 85100.00
as per drawing and Technical Specifications complete as per
specifications MORTH Specification No.1000, 2000 & 2200 (PWD
SR2009-10/P.No. 198/28.14)

28.15 KSRRB M2200-11. Supplying, fitting and fixing in position true to line and
level forged steel roller Bearing conforming to IRC: 83(Pt.-1)section IX and
clause 2000.3 of MORHT Specifications complete including all accessories
Tonne
as per drawing and Technical Specifications complete as per
specifications MORTH Specification No.1000, 2000 & 2200 (PWD
SR2009-10/P.No. 198/28.15)

28.16 KSRRB M2200-12. Supplying, fitting and fixing in position true to line and
level sliding plate Bearing with PIFE surface sliding on stainless steel
complete including all accessories as per drawing and Technical
Tonne 85100.00
Specifications and BS: 5400, section 9.1 & 9.2 (for PIFE) and clause
2000.4 of MORTH complete as per specifications MORTH Specification
No. 2000 & 2200 (PWD SR2009-10/P.No. 198/28.16)

28.17 KSRRB M2200-13. Supplying, fitting and fixing in position true to line and
level elastomeric Bearing conforming to IRC:83 (Part-II) section IX and
clause 2000.5 of MORTH specifications complete including all accessories
C.C 0.65
as per drawing and Technical specifications complete as per specifications
MORTH Specification No. 2000 & 2200 (PWD SR2009-10/P.No.
198/28.17)

28.18 KSRRB M2200-14. Supplying, fitting and fixing in position true to line and
level sliding plate Bearing with stainless steel plate sliding on stainless
steel plate with miil steel matrix complete including all accessories as per
Tonne 85050.00
drawing and Technical Specifications complete as per specifications
MORTH Specification No. 2000 & 2200 (PWD SR2009-10/P.No.
198/28.18)

28.19
KSRRB M2200-15. Supplying, fitting and fixing in position true to line and
level POT-PTFE Bearing consisting of a metal piston supported by a disc
or unreinforced elasromer confined within a metal cylinder, sealing rings,
dust seals, PTFE surface sliding against stainless steel mating surface,
complete assembly to be of cast steel/fabricated structural steel, metal and
Tonne 85150.00
elastomer elements to be as per IRC:83 part-I & II respectively and other
parts conforming to BS:5400, section 9.1 & 9.2 and clause 2000.6 of
MORTH Specifications complete as per drawing and approved Technical
Specifications complete as er specifications MORTH Specification No.
2000 & 2200 (PWD SR2009-10/P.No. 198/28.19)

BRIDGES - CONCRETE SUPERSTRUCTURE


KSRRB M2300 - For Solid Slab
29.1 KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 200/29.1)

29.1.1
KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade Cum 4540.00
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. Height upto 5 m (PWD SR2009-10/P.No. 200/29.1.1)

29.1.2
KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade Cum 4730.00
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 200/29.1.2)

29.1.3
KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade Cum 4920.00
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. Height above10 m (PWD SR2009-10/P.No. 200/29.1.3)

KSRRB M2300-For T-beam and Slab


29.2 KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 200/29.2)

29.2.1
KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade Cum 4735.00
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height upto 5 m (PWD SR2009-10/P.No. 200/29.2.1)

29.2.2
KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade Cum 4925.00
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 200/29.2.2)

29.2.3
KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade Cum 5110.00
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 10 m (PWD SR2009-10/P.No. 200/29.2.3)

KSRRB M2300 - For Solid Slab


29.3 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700.(PWD SR2009-10/P.No.
200/29.3)
29.3.1 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
Cum 4350.00
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height upto 5 m (PWD
SR2009-10/P.No. 200/29.3.1)

29.3.2 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
Cum 4530.00
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height 5 m to 10 m (PWD
SR2009-10/P.No. 200/29.3.2)

29.3.3 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
Cum 4710.00
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height above 10 m (PWD
SR2009-10/P.No. 200/29.3.3)

KSRRB M2300- For T-beam and Slab


29.4 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. (PWD SR2009-10/P.No.
200/29.4)

29.4.1 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
Cum 4530.00
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height upto 5 m (PWD
SR2009-10/P.No. 200/29.4.1)

29.4.2 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
Cum 4710.00
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height 5 m to 10 m (PWD
SR2009-10/P.No. 200/29.4.2)

29.4.3 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
Cum 4900.00
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height above 10 m (PWD
SR2009-10/P.No. 200/29.4.3)

KSRRB M2300 - For Solid Slab


29.5 KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 201/29.5)
29.5.1
KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 4960.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 5 m (PWD SR2009-10/P.No. 201/29.5.1)

29.5.2
KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5170.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 201/29.5.2)

29.5.3
KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5380.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 10 m (PWD SR2009-10/P.No. 201/29.5.3)

KSRRB M2300-3.2 For T-beam and Slab


29.6 KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 201/29.6)

29.6.1
KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5170.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height upto 5 m (PWD SR2009-10/P.No. 201/29.6.1)

29.6.2
KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5380.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 201/29.6.2)

29.6.3
KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5580.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 10 m (PWD SR2009-10/P.No. 201/29.6.2)

KSRRB M2300-For Solid Slab


29.7 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700. (PWD SR2009-10/P.No.
201/29.7)
29.7.1 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 4770.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height upto 5 m (PWD
SR2009-10/P.No. 201/29.7.1)

29.7.2 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 4970.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height 5 m to 10 m(PWD
SR2009-10/P.No. 201/29.7.2)

29.7.3 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 5170.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height above 10 m(PWD
SR2009-10/P.No. 201/29.7.3)

KSRRB M2300-For T-beam and Slab


29.8 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.(PWD SR2009-10/P.No.
201/29.8)

29.8.1 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 4970.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height upto 5m(PWD
SR2009-10/P.No. 201/29.8.1)

29.8.2 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 5170.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height 5m to 10 m(PWD
SR2009-10/P.No. 201/29.8.2)

29.8.3 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 5370.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700. Height above 10 m (PWD
SR2009-10/P.No. 201/29.8.3)

KSRRB M2300-FOR SOLID SLAB


29.9 KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 201-202/29.9)
29.9.1
KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5030.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.9.1) Height upto 5m

29.9.2
KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5240.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.9.2) Height 5m to 10m

29.9.3
KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5450.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.9.3) Height above 10m

KSRRB M2300-For T-beam and Slab


29.10 KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10)

29.10.1
KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5240.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10.1) Height upto 5m

29.10.2
KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5450.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10.2) Height 5m to 10m

29.10.3
KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5660.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10.3) Height above 10m

KSRRB M2300 - For Solid Slab


29.11 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11)

29.11.1 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 4830.00
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11.1) Height upto 5 m
29.11.2 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5030.00
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11.2) Height 5 m 10 m

29.11.3 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5230.00
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11.3) Height above 10 m

KSRRB M2300- For T-beam and Slab


29.12 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12)

29.12.1 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5030.00
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12.1) Height upto 5m

29.12.2 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5230.00
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12.2) Height 5m to 10m

29.12.3 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5430.00
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12.3) Height above 10m

KSRRB M2300 - For Soild Slab


29.13
KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 202/29.13)

29.13.1 KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5050.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.13.1)
Height upto 5 m
29.13.2 KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5270.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.13.2)
Height 5 m to 10 m

29.13.3 KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5480.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.13.3)
Height above 10 m

KSRRB M2300- For T-beam and Slab


29.14
KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14)

29.14.1 KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5270.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14.1)
Height upto 5m

29.14.2 KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5480.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14.2)
Height 5m to 10m

29.14.3 KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5700.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14.3)
Height above 10m

KSRRB M2300- For box girder & balanced cantilever


29.15 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15)

29.15.1 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5910.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15.1)
Height upto 5m
29.15.2 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6340.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15.2)
Height 5m to 10m.

29.15.3 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6770.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15.3)
Height above 10m

KSRRB M2300 - For Solid Slab


29.16 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16)

29.16.1 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 4850.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16.1) Height upto 5m

29.16.2 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5060.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16.2) Height 5m to 10m

29.16.3 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5270.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16.3) Height above 10m

KSRRB M2300- For T-beam and Slab


29.17 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.17)

29.17.1 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5060.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.17.1) Height upto 5m
29.17.2 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5270.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.17.2) Height 5m to 10m

29.17.3 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5470.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.17.3) Height above 10m

KSRRB M2300 - For box girder and balanced cantilever


29.18 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18)

29.18.1 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5680.00
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18.1) Height upto 5m

29.18.2 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6090.00
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18.2) Height 5m to 10m

29.18.3 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6500.00
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18.2) Height above 10m

KSRRB M2300 - For Solid Slab


29.19 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19)

29.19.1 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5340.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19.1)
Height upto 5m
29.19.2 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5470.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19.2)
Height 5m to 10m

29.19.3 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5670.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19.3)
Height above 10m

KSRRB M2300 - For T-beam and Slab


29.20 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20)

29.20.1 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5470.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20.1)
Height upto 5m

29.20.2 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5670.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20.2)
Height 5m upto 10m

29.20.3 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5860.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20.3)
Height above 10m

KSRRB M2300 - For Solid Slab / Voided Slab


29.21 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
204/29.21)

29.21.1 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump. Cum 5040.00
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
205/29.21.1) Height upto 5 m
29.21.2 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump. Cum 5240.00
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
205/29.21.2) Height 5 m to 10 m

29.21.3 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump. Cum 5440.00
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
205/29.21.3) Height above 10 m

KSRRB M2300-For-T-Beam and Slab, including launching of precast


girder by launching truss upto 40m span
29.22 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22)

29.22.1 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5240.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22.1) Height upto 5
m

29.22.2 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5440.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22.2) Height 5 m to
10 m

29.22.3 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5650.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22.3) Height above
10 m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.23 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23)

29.23.1 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5860.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23.1) Height upto 5
m
29.23.2 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 6270.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23.2) Height 5 m to
10 m

29.23.3 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 6680.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23.3) Height above
10 m

KSRRB M2300- For Solid Slab/Voided Slab


29.24 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24)

29.24.1 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
Cum 5200.00
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24.1) Height upto 5 m

29.24.2 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
Cum 5420.00
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24.2) Height 5 m to 10 m

29.24.3 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
Cum 5630.00
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24.3) Height above10 m

KSRRB M2300-For T-beam and Slab, including launching of precast


girder by launching truss upto 40 m span
29.25 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25)

29.25.1 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 5420.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25.1) Height upto 5 m

29.25.2 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 5630.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25.2) Height 5m to 10m
29.25.3 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 5850.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25.3) Height above 10m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.26 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26)

29.26.1 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 6070.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26.1) Height upto 5 m

29.26.2 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 6500.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26.1) Height 5 m to 10 m

29.26.3 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 6940.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26.1) Height above 10 m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.27 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27)

29.27.1 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade Cum 6240.00
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27.1) Height upto 5 m

29.27.2 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade Cum 6680.00
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27.2) Height 5 m to 10 m

29.27.3 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade Cum 7130.00
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27.3) Height above 10 m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.28 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28)

29.28.1 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade Cum 6560.00
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28.1) Height upto 5 m

29.28.2 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade Cum 7040.00
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28.2) Height 5 m to 10 m

29.28.3 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade Cum 7510.00
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28.3) Height above 10 m

KSRRB M2300-TMT bar Reinforcement


29.29 KSRRB M2300-14. Supplying, fitting and placing TMT bar reinforcement in
super-structure complete as per drawing and technical Specifications
Complete as per specifications MORTH Specification No. 1600 (PWD Tonne 44180.00
SR2009-10/P.No. 206/29.29)

KSRRB M2300- High tensile wires


29.30 KSRRB M2300-15. High tensile steel wires / strands including all
accessories for stressing, stressing operations and grouting complete as
per drawing and Technical Specificaitons Complete as per specificaitons Tonne 145900.00
MORHT Specificaton No. 1800 (PWD SR2009-10/P.No. 207/29.30)

KSRRB M2300 - Wearing Coat


29.31 KSRRB M2300-16. Providing and laying Cement concrete wearing coat M-
30 grade including reinforcement complete as per drawing and Technical
Specificaitons Complete as per specificaitons MORHT Specificaton No. Cum 7610.00
1800 (PWD SR2009-10/P.No. 207/29.31)

BRIDGES-RIVER TRAINING WORKS AND PROTECTION WORKS


30.1 KSRRBM2500-1.1. Providing and laying boulders apron on river bed for
protection against scour with stone boulders weighing not less than 40 kg
each complete as per drawing and Technical Specification complete as Cum 465.00
per specifications. A. Boulder Laid Dry Without Wire Crates. MORTH
Specification No. 2503. (PWD SR2009-10/P.No. 209/30.1)

30.2 KSRRBM2500-1.2. Providing and laying of boulder apron laid in wire


crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in
100mm x 100mm mesh (weaved diagonally) including 10% extra for laps
and joints laid with stone boulders weighing not less than 40 kg each Cum 1070.00
complete as per drawing and Technical Specification complete as per
specifications. B. Boulder Apron Laid in Wire Crates. MORTH
Specification No. 2503. (PWD SR2009-10/P.No. 209/30.2)

KSRRB M2500-Cement Concrete blocks


30.3 KSRRBM2500-2. Providing and laying of apron with cement concrete
blocks of size 0.5x0.5x0.5 m cast-in-situ and made with nominal mix of M-
15 grade cement concrete with a minimum cement content of 250 kg/cum Cum 3980.00
as per IRC: 21-2000 complete as per specifications. MORTH Specification
No. 2503. (PWD SR2009-10/P.No. 209/30.3)

KSRRB M2500-Pitching
30.4 KSRRBM2500-3. Providing and laying Filter material underneath pitching
in slopes complete as per drawing and Technical specifications. MORTH Cum 930.00
Specification No. 2504. (PWD SR2009-10/P.No. 209/30.4)

30.5 KSRRBM2500-4.1. Providing and laying Pitching on slopes laid over


prepared filter media including boulder apron laid dry in front of toe of
embankment complete as per drawing and Technical specifications. A. Cum 465.00
Stone / Boulder. MORTH Specification No. 2504. (PWD SR2009-
10/P.No. 209/30.5)

30.6 KSRRBM2500-4.2. Providing and laying Pitching on slopes laid over


prepared filter media including boulder apron laid dry in front of toe of
embankment complete as per drawing and Technical specifications. B.
Cum 3980.00
Cement Concrete Blocks of size 0.3x0.3x0.3 m cast in cement
concrete of Grade M-15. MORTH Specification No. 2504. (PWD
SR2009-10/P.No. 209/30.6)

KSRRB M2500-Flooring with Rubble Stone


30.7
KSRRBM2500-5.1. Providing and laying Flooring complete as per drawing
and Technical specifications laid over cement concrete bedding complete
Cum 2390.00
as per specification. A. Rubble stone laid in cement mortat 1:3..
MORTH Specification No. 2505. (PWD SR2009-10/P.No. 209/30.7)

30.8
KSRRBM2500-5.2. Providing and laying Flooring complete as per drawing
and Technical specifications laid over cement concrete bedding complete
Cum 4390.00
as per specification. B. Cement Concrete Blocks Grade M-15".. MORTH
Specification No. 2505. (PWD SR2009-10/P.No. 209/30.8)

30.9 KSRRBM2500-6. Dry rubble flooring Construction of dry rubble flooring


at cross drainage works for relatively less important works complete as per
Cum 630.00
specification. MORTH Specification No. 2506. (PWD SR2009-10/P.No.
209/30.8)

KSRRB M2500- Geotextile filter


30.10 KSRRBM2500-7. Laying of a geotextile filter between pitching and
embankment slopes on which pitching is laid to prevent escapes of the
embankment material through the voids of the stone pitching/cement
concrete blocks as well as to allow free movement of water without Sqm 86.00
creating any uplift head on the pitching complete as per specification.
MORTH Specification No. 700 & 2504. (PWD SR2009-10/P.No.
210/30.10)

KSRRB M2500-Curtain Wall


30.12 KSRRBM2500-9. Curtain Wall complete as per drawing and Technical
specifications. A. Stone masonry in cement mortar (1:3). MORTH Cum 2160.00
Specification No. 2507.2. (PWD SR2009-10/P.No. 210/30.12)

30.13 KSRRBM2500-10. Curtain Wall complete as per drawing and Technical


specifications. B. Cement Concrete Grade M-15. MORTH Specification Cum 3890.00
No. 2507.2. (PWD SR2009-10/P.No. 210/30.13)

KSRRB M2500 - Flexible Apron


30.14 KSRRBM2500-11.Construction of flexible apron 1 m thick comprising of
loose stone boulders weighing not less than 40 kg beyond curtain wall
Cum 495.00
complete as per specifications. MORTH Specification No. 2507.2. (PWD
SR2009-10/P.No. 210/30.14)

KSRRB M2500 - Garbain Structure


30.15
KSRRBM2500-12.Providing and Constructing of a garbain structure for
retaining earth with segments of wire crates of size 7m x 3m x 0.6 m each
divided into 1.5 m compartments by cross netting, made from 4 mm
galvanised steel wire at 32 kg per 10 sqm having minimum tensile strength
of 300 Mpa conforming to IS:280 and galvanizing coating confirming to IS:
Cum 1185.00
4826, woven into mesh with double twist, mesh size not exceeding 100 x
100 mm, filled with boulders with least dimenstion of 200 mm, all loose
ends to be tied with 4 mm galvanised steel wire complete as per
specifications. MORTH Specification No. 2503.3. (PWD SR2009-10/P.No.
210/30.15)

30.16
KSRRBM2500-13. Gabian structure for Erosion Control, River Training
Works and Protection works Providing and Constructing gabian structures
for erosion control, river training works and protection works with wire
crates of size 2m x 1m x 0.3m each divided into 1m compartments by
cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10 Sqm
having minimum tensile strength of 300 Mpa conforming to IS:280 and Cum 2190.00
galvanizing coating conforming to IS:4826, woven into mesh with double
twist, mesh size not exceeding 100 mm x 100 mm, filled with boulders with
least dimension of 200 mm, all loose ends to be securely tied with 4 mm
galvanised steel wire complete as per specifications. MORTH Specification
No. 2503.3. (PWD SR2009-10/P.No. 210/30.16)

EXPANSION JOINTS
KSRRB M2600 - Expansion Joints
31.1 Ksrrb M2600 - 1. Providing and laying a burried expanshion joints,
expanshion gap being 20 mm, covered with 12 mm thick, 200 mm wide
galvanised welded structural steel plate as per IS: 2062, placed
symmetrical to centre line of the joints, resting freely as over the tpo
m 1110.00
surface of the deck concrete, welding of 8 mm dia, 100 mm long
galvanised nails spaced 300 mm c/c along the centre line of the plate, all
as specified in clause 2600.4 MORTH Specification No. 2604 (PWD
SR2009-10/P.No. 212/31.1)

KSRRB M2600 - Filler Joint


31.2 KSRRB M2600-2. i) Providing and fixing 2 mm thick corrugated copper
plate in expasion joint complete as per drawing & Technical Specificaiton
m 1935.00
complete as per specifications. MORTH Specification No. 2605. (PWD
SR2009-10/P.No. 212/31.2)

31.3 KSRRB M2600-3. ii) Providing and fixing 20 mm thick compressible fibre
board in expasion joint complete as per drawing & Technical Specificaiton
m 125.00
complete as per specifications. MORTH Specification No. 2605. (PWD
SR2009-10/P.No. 212/31.3)

31.4 KSRRB M2600-4. iii) Providing and fixing in 20 mm thick premoulded joint
filler in expansion joint for fixed ends of simply supported spans not
exceeding 10m to cater for a horizontal movement upto 20 mm, covered
Smtr 660.00
with sealant complete as per drawing & Technical Specificaiton complete
as per specifications. MORTH Specification No. 2605. (PWD SR2009-
10/P.No. 212/31.4)
31.5 KSRRB M2600-4. iv) Providing and filling joint sealing compound as per
drawings and Technical specifications with coarse sand and 6 per cent
Smtr 45.00
bitumen by weight complete as per specifications. (PWD SR2009-
10/P.No. 212/31.5)

KSRRB M2600 - Asphaltic Plug Joint


31.6
Ksrrb M2600 - 6. Providing and laying of asphaltic plug joint to procide for
horizontal movement of 25 mm and vertical movement of 2 mm, depth of
joint varying from 75 mm to 100 mm, width varying from 500 mm to 750
mm (in traffic direction), covered with a closure plate of 200mm x 6mm of
welded structural steel confirming ti IS: 2062, asphaltic plug to consist of
m 800.00
polymer modified bitumen binder, carefully selected single size aggregate
of 12.5 mm nominal size and a heat resistant foam caulking/backer rod, all
as per approved drawings and specifications, complete as per
specifications, MORTH Specification No. 2600 (PWD SR2009-10/P.No.
213/31.6)

KSRRB M2600 - Elastomeric Slab Seal Expansion Joint


31.7 Ksrrb M2600 - 7. Providing and laying of an elastomeric slab steel
expanstion joints, catering to right or skew (less than 20 deg, moderately
curved with maximum horizontal movement upto 50mm, complete as per
approved drawings and standard specifications to be installed by the
manufacturer/supplier or their authorised representative ensuring m 15140.00
compliance to the manufacturer's instruction for installation and clause
2600.6 of MORTH Specifications for road & bridge work complete as per
specifications. MORTH Specification No. 2606 . (PWD SR2009-10/P.No.
213/31.7)

KSRRB M2600 - Compression Seal Joint


31.8
Ksrrb M2600 - 8. Providing and laying of compression seal joint consisting
of steel armoured nosing at two edges of the joint gap suitably anchored to
the deck concrete and preformed chloroprene elastomer or closed cell
foam joint sealer compressed and fixed into the joint gap special adhesive m 17590.00
binder to cater for a horizontal movement upto 40 mm and vertical
movement of 3 mm complete as per specifications. MORTH Specification.
2600. (PWD SR2009-10/P.No. 213/31.8)

KSRRB M2600 - Strip Seal Expanshion Joint


31.9 Ksrrb M2600 - 9. Providing and laying of a strip seal expanshion joint
catering to maximum horizontal movement upto 70 mm, complete as per
approved drawings and standard specifications to be installed by the
manufacturer/Supplier or their authorised representative ensuring m 14500.00
compliance to the manufacturer's instructions for installation complete as
per specifications. MORTH Specification. 2607. (PWD SR2009-10/P.No.
213/31.9)

KSRRB M2600 - Modular Strip / Box Seal Joint


31.10
Ksrrb M2600 -10. Providing and laying of a modular strip Box seal
expanshion joint including anchorage catering to a horizontal movement
beyond 70 mm and upto 140 mm, complete as per approved drawings and
standard specifications to be installed by the manufacturer/Supplier or their m 6500.00
authorised representative ensuring compliance to the manufacturer's
instructions for installation complete as per specifications. MORTH
Specification. 2600. (PWD SR2009-10/P.No. 213/31.10)
31.11 Ksrrb M2600 -11. Providing and laying of a modular strip Box seal
expanshion joint catering to a horizontal movement beyond 140 mm and
upto 210 mm, complete as per approved drawings and standard
specifications to be installed by the manufacturer/Supplier or their m 7820.00
authorised representative ensuring compliance to the manufacturer's
instructions for installation complete as per specifications. MORTH
Specification. 2600. (PWD SR2009-10/P.No. 213/31.11)

BRIDGES - WEARING COAT & APPURTEANCES


KSRRB M2700 - Mastic Asphalt
32.1
KSRRB M2700 -1. Providing and laying 12mm thick mastic asphalt
wearing course on top of deck slab excluding prime coat with paving grade
bitumen meeting the requirements given in table 500-29, prepared by
using mastic cooker and laid to required level and slope after cleaning the
surface, including providing antiskid surface with bitumen precoated fine
grained hard stone chipping of 9.5 mm nominal size at the rate of 0.05 Sqm 183.00
cum per 10 sqm and at an approximate spacing of 10 m center to center in
both directions, pressed into surface when the temperature of surfaces not
less than 100 deg, C, protruding 1 mm to 4 mm over mastic surface, all
complete as per clause 5100.5 complete as per specifications. MORTH
Specification No. 515 & 2702. (PWD SR2009-10/P.No. 216/32.1)

KSRRB M2700 - Railing


32.2 KSRRB M2700 -2. Construction of precast RCC railling of M-30 grade,
aggregates size not exceeding 12 mm, true to line and grade, tolerance of
vertical RCC post not to exceed 1 in 500, centre to concrete spacing
between vertical post not to exceed 2000 mm, leaving adequate space
m 1170.00
between vertical post for expanshion, complete asper approved drawings
and technical specifications complete as per specifications. MORTH
Specification No. 2703, 1500, 1600 & 1700. (PWD SR2009-10/P.No.
216/32.2)

32.3 KSRRB M2700 -3. Construction of RCC railling of M-30 grade, in-situ with
20 mm nominal size aggregate, true to line and grade, tolerance of
vertical RCC post not to exceed 1 in 500, centre to concrete spacing
between vertical post not to exceed 2000 mm, leaving adequate space
m 1160.00
between vertical post for expanshion, complete asper approved drawings
and technical specifications complete as per specifications. MORTH
Specification No. 2703, 1500, 1600 & 1700. (PWD SR2009-10/P.No.
216/32.3)

32.4 KSRRB M2700 -4. Providing, fitting and fixing mild steel railing complete
asper approved drawings and technical specifications complete as per
m 2340.00
specifications. MORTH Specification No. 2703.2, 1900. (PWD SR2009-
10/P.No. 216/32.4)

32.5
KSRRB M2700 -5. Drainage Spouts complete asper approved drawings
and technical specifications complete as per specifications. MORTH No 1150.00
Specification No. 2703.2, 1900. (PWD SR2009-10/P.No. 216/32.5)

KSRRB M2700 - Approach Slab


32.6 KSRRB M2700 -6. PCC M-15 Grade leveling course below approach slab
complete asper approved drawings and technical specifications complete
Cum 3950.00
as per specifications. MORTH Specification No. 2703.2, 1900. (PWD
SR2009-10/P.No. 216/32.6)
32.7 KSRRB M2700 -7. Reinforced cement concrete approach slab grade
M30 including reinforcement and formwork complete asper approved
drawings and technical specifications complete as per specifications. Cum 7610.00
MORTH Specification No. 2703.2, 1900. (PWD SR2009-10/P.No.
216/32.7)

KSRRB M2700 - Precast Pretensioned Girders


32.9
KSRRB M2700 -9. Providing, precasting, transportation and placing in
position precast pretensioned concrete girders as per drawings and
Cum 15980.00
technical specifications complete as per specifications. MORTH
Specification No.1800 & 2300 PWD SR2009-10/P.No. 217/32.9)

32.10 KSRRB M2700 -10. Providing, and fixing Helical pipes in voided
concrete slabs complete as per specifications. MORTH Specification No. m 295.00
1700 & 1800.. (PWD SR2009-10/P.No. 217/32.10)

KSRRB M2700 - Painting on Concrete Surface


32.11 KSRRB M2700 -12. Providing, and applying 2 coats of water based
cement paint to unplastered concrete surface after cleaning the surface of
dirt, dust, oil, grease, efflorescence and applying paint of 1 litre for 2 sqm Sqm 29.00
complete as per specifications. MORTH Specification No. 800.(PWD
SR2009-10/P.No. 217/32.11)

33.00
BRIDGES - REPAIR AND REHABILITATION
33.1 KSRRB M2800-1. Removal of existing cement wearing coat including
its disposal complete as per Technical Specification without causing any
determental effect to any part of the bridge structure and removal of
Sqm 58.00
dismantled with all lifts and lead upto 1000 m complete as per
specifications. MORTH Specification No. 2809.(PWD SR2009-10/P.No.
219/33.1)

33.2 KSRRB M2800-2. Removal of existing asphalt wearing coat comprising


of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt
including its disposal with all lifts and lead upto 1000 m complete as per Sqm 47.00
specifications. MORTH Specification No. 2809.(PWD SR2009-10/P.No.
219/33.2)

33.3 KSRRB M2800-3. Guniting concrete surface with cement mortar


applied with compressor after cleaning surface and spraying with epoxy
Sqm 520.00
complete as per Technical Specification, complete as per specifications.
MORTH Specification No. 2807.(PWD SR2009-10/P.No. 219/33.3)

33.4 KSRRB M2800-4. Providing and inserting nipples with approved fixing
compound after drilling holes for grouting as per Technical specifications
including subsequent cutting/removal and sealing of the holes as
No 52.00
necessary of nipples after completion of grouting with Cement / Epoxy
complete as per specifications. MORTH Specification No. 2800.(PWD
SR2009-10/P.No. 219/33.4)

33.5 KSRRB M2800-5.1. Sealing of cracks/porous concrete by injection


process through nipples/Grouting complete as per Technical Specification
Kgs 150.00
A. Cement Grout" complete as per specifications. MORTH Specification
No. 2800.(PWD SR2009-10/P.No. 219/33.5)
33.6
KSRRB M2800-5.2. Sealing of cracks/porous concrete by injection
process through nipples/Grouting complete as per Technical Specification
Kgs 182.00
A. Cement Mortar (1:1) Grouting" complete as per specifications. MORTH
Specification No. 2806.(PWD SR2009-10/P.No. 219/33.6)

33.7
KSRRB M2800-6.Patching of damaged concrete surface with polymer
concrete and curing complounds, initiator and promoter, available in
present formulations, to be applied as per instructions of manufacturer and Sqm 595.00
as approved by the Engineer complete as per specifications. MORTH
Specification No. 2800.(PWD SR2009-10/P.No. 219/33.7)

33.8 KSRRB M2800-7.Sealing of crack/porous concrete with Epoxy Grout


by injection through nipples complete as per specifications. MORTH Kgs 325.00
Specification No. 2800.(PWD SR2009-10/P.No. 219/33.8)

33.9 KSRRB M2800-8.Applying Epoxy mortar over leached, honey combed


and spalled concrete surface and exposed steel reinforcement complete
Sqm 405.00
as per Technical Specification MORTH Specification No. 2800.(PWD
SR2009-10/P.No. 219/33.9)

33.10
KSRRB M2800-9 Removal of defective concrete, cleaning the surface
throughly, applying the shotcrete mixture mechanically with compressed
air under pressure, comprising of cement, sand, coarse aggregates, water
and quick setting compound in the proportion as per clause 28007.1. sand
and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 Sqm 172.00
respectivelly, water cement ratio ranging from 0.35 to 0.50, density of
gunite not less than 2000 kg/cum, strength not less than 25 Mpa and
workmanship confirming to clause 2800.7.6 complete as per Specifications
MORTH Specification No. 2807.(PWD SR2009-10/P.No. 220/33.10)

33.11 KSRRB M2800-10. Applying pre-packed cement based polymer


mortar of strength 45 Mpa at 28 days for replacement of spalled concrete
Sqm 124.00
complete as per Specifications MORTH Specification No. 2800.(PWD
SR2009-10/P.No. 220/33.11)

33.12 KSRRB M2800-11. Epoxy bonding of new concrete to old concrete


complete as per Specifications MORTH Specification No. 2805.(PWD Sqm 510.00
SR2009-10/P.No. 220/33.12)

33.13
KSRRB M2800-12.1. Providing external prestressing with high tensile
steel wires / strands inclduing drilling for passage of prestressing steel, all
accessories for stressing and stressing operation and grouting complete Tonne 362800.00
asper drawing and technical Specification complete as per Specifications
MORTH Specification No. 2810.(PWD SR2009-10/P.No. 220/33.13)

33.14
KSRRB M2800-12.2. Providing external prestressing with high tensile
steel wires / strands inclduing drilling for passage of prestressing steel, all
accessories for stressing and stressing operation and grouting complete Tonne 263400.00
asper drawing and technical Specification complete as per Specifications
MORTH Specification No. 2810.(PWD SR2009-10/P.No. 220/33.14)

33.15
KSRRB M2800-12.3. Providing external prestressing with high tensile
steel wires / strands inclduing drilling for passage of prestressing steel, all
accessories for stressing and stressing operation and grouting complete Tonne 234700.00
asper drawing and technical Specification complete as per Specifications
MORTH Specification No. 2810.(PWD SR2009-10/P.No. 220/33.15)
33.16 KSRRB M2800-13. Replacement of Bearing complete as per Techniclal
Specifications MORTH Specification No. 2810.(PWD SR2009-10/P.No.
220/33.16)

33.16.1 KSRRB M2800-13. Replacement of Bearing Rocker & Roller complete


as per Techniclal Specifications MORTH Specification No. 2810.(PWD Nos 17900.00
SR2009-10/P.No. 220/33.16.1)

33.16.2 KSRRB M2800-13. Replacement of Bearing Neoprene complete as per


Techniclal Specifications MORTH Specification No. 2810.(PWD SR2009- No 15250.00
10/P.No. 220/33.16.2)

33.18 KSRRB M2800-15. Replacement of Expanshion Joints complete as per


m 2560.00
Techniclal Specifications (PWD SR2009-10/P.No. 220/33.18)

33.19 KSRRB M2800-16. Replacement of Damaged Concrete Railing


complete as per Techniclal Specifications (PWD SR2009-10/P.No. m 1270.00
220/33.19)

33.20 KSRRB M2800-17. Replacement of Crash Barrier complete as per


m 2060.00
Techniclal Specifications (PWD SR2009-10/P.No. 220/33.20)

33.21 KSRRB M2800-18. Replacement of Damaged Mild steel Railing


complete as per Techniclal Specifications (PWD SR2009-10/P.No. m 2420.00
220/33.21)

33.22 KSRRB M2800-19. Repair of Crash Barrier: Repair of concrete crash


barrier with cement concrete M-30 grade by cutting and trimminng the
damaged portion to a regular shape, cleaning the area to be repaired
m 245.00
thoroughly, applying cement concrete after erection of proper form work
complete as per Techniclal Specifications (PWD SR2009-10/P.No.
220/33.22)

33.23 KSRRB M2800-20. Repair of Rcc Railing Carrying out repair of RCC M-
30 railling to bring it to the original shape complete as per Techniclal m 137.00
Specifications (PWD SR2009-10/P.No. 220/33.23)

33.24 KSRRB M2800-21. Repair of Steel Railing to bring it to the original


shape complete as per Techniclal Specifications (PWD SR2009-10/P.No. m 215.00
220/33.24)

34.00 PIPE CULVERTS


KSRRB M2900 - PCC 1:3:6 in Foundation
34.1 KSRRB M2900-1. Plain cement concrete 1:3:6 mix with crushed stone
aggregate 40 m nominal size mechanically mixed, placed in foundation
and compacted by vibration including curing for 14 days complete as per Cum 2955.00
Specifications. MORTH Specification No. 408. (PWD SR2009-10/P.No.
223/34.1)

34.2 KSRRB M2900-2.1. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in single row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 4750.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2009-10/P.No. 223/34.2) A.
1000 mm dia.
34.3 KSRRB M2900-2.2. Laying Reinforced cement concrete pipe NP4/
prestressed concrete pipe for culverts on first class bedding of granular
material in single row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 4920.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2009-10/P.No. 223/34.3) A.
1200 mm dia.

34.4 KSRRB M2900-3.1. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in double row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 9540.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2009-10/P.No. 223/34.4) A.
1000 mm dia.

34.5 KSRRB M2900-3.2. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in double row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 9880.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2009-10/P.No. 223/34.4) A.
1200 mm dia.

34.6 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6)

34.6.1
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1110.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6.1)300 mm dia

34.6.2
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1700.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6.2)450 mm dia

34.6.3
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 2270.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6.3)600 mm dia

34.6.4
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3650.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6.4)750 mm dia
34.6.5
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3760.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6.5)900 mm dia

34.6.6
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 5660.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 223/34.6.6)1200 mm dia

34.7 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7)

34.7.1
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 385.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.1)150mm dia

34.7.2
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 515.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.2)250mm dia

34.7.3
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 765.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.3)300mm dia

34.7.4
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1120.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.4)450mm dia

34.7.5
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1730.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.5)600mm dia

34.7.6
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 2410.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.6)750mm dia
34.7.7
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3030.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.7)900mm dia

34.7.8
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3930.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2009-10/P.No. 224/34.7.8)1200mm dia

MAINTENANCE OF ROADS
KSRRB M3000 - Restoration of Rain Cuts
35.1 KSRRB M3000-1 Restoration of rain cuts with soil, moorum, gravel or a
mixture of these, clearing the loose soil, benching for 300 mm width, laying
fresh material in layers not exceeding 250 mm and compacting with plate
m 54.00
compactor or power rammers to restore the original alignment, levels and
slopes complete as per specifications. MORTH Specification No. 3002
(PWD SR 2009-10/P.No. 226/35.1)

KSRRB M3000- Maintenance of Earthen Shoulder


35.2
KSRRB M3000-2. Making up loss of material/irregularation on shoulder to
the design level by adding fresh approved soil and compacting it with
Sqm 14.00
appropriate equipment complete as per specifications. MORTH
Specification No. 3003. (PWD SR 2009-10/P.No. 226/35.2)

35.3 KSRRB M3000-3. Stripping excess soil from the Shoulder surface to
achieve the approved level and compacting with plate compactor complete
Sqm 5.30
as per specifications. MORTH Specification No 3003. (PWD SR 2009-
10/P.No. 226/35.3)

35.4
KSRRB 3000: Filling Pot-holes and Patch Repairs with open graded
Premix surfacing, 20mm. KSRRB M3000-4 : Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per Sqm 100.00
cluase 500.11, compacting, trimming and finishing the surface to form a
smooth continuous suface, all as per clause 3004.2 MORT & H using
80/i00 bituminous (Nominal size) (Bitumen = 0.00146, Metal = 0.027,
Emulsion = 0.00024) (PWD SR 2009-10/P.No. 226/35.4)

35.4.1
KSRRB 3000: Filling Pot-holes and Patch Repairs with open graded
Premix surfacing, 20mm. KSRRB M3000-4 : Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per
Sqm 102.00
cluase 500.11, compacting, trimming and finishing the surface to form a
smooth continuous suface, all as per clause 3004.2 MORT & H using
80/i00 bituminous (Nominal size) (Bitumen = 0.00146, Metal = 0.027,
Emulsion = 0.00024) (PWD SR 2009-10/P.No. 226/35.4.1) Using 60/70
grade bitumen (packed)
35.5
KSRRB 3000: Filling Pot-holes and Patch Repairs with Bituminious
Concrete, 40mm. KSRRB M3000-5 : Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per
Sqm 255.00
cluase 500.4, compacting, trimming and finishing the surface to form a
smooth continuous suface, all as per clause 3004.2 complete as per
Specifications using 80/100 bituminous (Packed) (Bitumen = 0.00459,
Metal = 0.581, Emulsion = 0.00024)MORT & H Specification No. 3004.2
(PWD SR 2009-10/P.No. 226/35.5)

35.5.1
KSRRB 3000: Filling Pot-holes and Patch Repairs with Bituminious
Concrete, 40mm. KSRRB M3000-5 : Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per
Sqm 260.00
cluase 500.4, compacting, trimming and finishing the surface to form a
smooth continuous suface, all as per clause 3004.2 complete as per
Specifications using 80/100 bituminous (Packed) (Bitumen = 0.00459,
Metal = 0.581, Emulsion = 0.00024)MORT & H Specification No. 3004.2
(PWD SR 2009-10/P.No. 226/35.5.1) using 60/70 grade bitumen (packed)

KSRRB M3000 Crack Filling


35.6 KSRRB M3000-6. Filling of crack using slow - curing bitumen emulsion
and applying crusher dust in case crack are wider than 30 mm complete
m 2.40
as per specifications. MORTH Specification No. 3004.3.3 (PWD SR 2009-
10/P.No. 226/35.6)

KSRRB M3000-Dusting
35.7 KSRRB M3000-7. Applying crusher dust to areas of road where bleeding
of excess bitumen has occurred complete as per specifications MORTH m 0.40
Specification No. 3004.4 (PWD SR 2009-10/P.No. 226/35.7)

35.8 KSRRB 3000 Repair of Joint Grooves with Epoxy Mortar.


KSRRB M3000-8. Repair of spalled joint grooves of contraction joints,
longitudinal joints, and expanshion joints in concrete pavements using
m 345.00
epoxy mortar or epoxy concrete complete as per specifications. MORTH
Specification No. 3005.1 (PWD SR 2009-10/P.No. 227/35.8)

KSRRB M3000-Repair of Old Joint Sealant


35.9 KSRRB M3000-9. Removal of existing sealant and re sealing of
contraction,longitudinal or expansion joints in concrete pavement with
m 48.00
fresh sealant material complete as per specifications. MORHT
Specification No. 3005-2 (PWD SR 2009-10/P.No. 227/35.9)

KSRRB M3000- Hill Side Drain Clearance


35.10
KSRRB M3000-10. Removal of earth from the chocked hill side drain and
disposing it on the valley side manually complete as per specificaitons m 18.00
MORTH Specification No 3000. (PWD SR 2009-10/P.No. 227/35.10)

KSRRB M3000- Landside Clearance in Soil


35.11 KSRRB M3000-11. Clearence of land sides in soil and ordinary roack by a
bull-dozer D 80 A-12, 180 HP and disposal of the same on the valley side
Cum 9.20
complete as per specificaitons MORTH Specification No 3000. (PWD SR
2009-10/P.No. 227/35.11)

KSRRB M3000 - Landside Clearance in Hard Rock Requiring Blasting


35.12 KSRRB M3000-12. Clearing and land sides in hard rock requiring blasting
for 50% of the boulders and disposal of the same on the vally side
Cum 48.00
complete as per specifications.MORTH Specification No. 3000. (PWD SR
2009-10/P.No. 227/35.12)

REINFORCED EARTH STRUCTURE


36.1
KSRRB M3100-2. Assembling, joining and laying of reinforcing elements.
A. With reinforcing element of steel / aluminium strips / polymeric strips m 245.00
.MORTH Specification No. 3102. (PWD SR 2009-10/P.No. 229/36.1)

36.2 KSRRB M3100-3. Assembling, joining and laying of reinforcing elements.


B. With reinforcing element of synthetic geogrids. .MORTH Specification Sqm 365.00
No. 3102. (PWD SR 2009-10/P.No. 229/36.2)

36.3 KSRRB M3100-4. Facing Elements of RCC MORTH Specification No.


Sqm 1170.00
3104. (PWD SR 2009-10/P.No. 229/36.3)

OTHER ITEMS
37.1 Providing erecting and removing casurinapole Barricading using poles of
7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at
intervals of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above
ground level, including fixing poles in the ground level for minimum depth
of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete. (PWD SR 2009-
10/P.No. 231/37.1)

37.1.1
Providing erecting and removing casurinapole Barricading using poles of
7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at
intervals of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above
ground level, including fixing poles in the ground level for minimum depth m 42.00
of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete. (PWD SR 2009-
10/P.No. 231/37.1.1) For two tier Barricading

37.1.2 Providing erecting and removing casurinapole Barricading using poles of


7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at
intervals of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above
ground level, including fixing poles in the ground level for minimum depth m 56.00
of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete. (PWD SR 2009-
10/P.No. 231/37.1.2) For three tier Barricading

37.2 Supplying and fixing M.S Rectangular poles made out of 2 equal angles of
65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm
dia M.S hold fast rods each of length 25 cms. Including cost of all materials
cutting, bending scaffolding wherver necessary, nicely finishing the welded
m 475.00
joints with all lead lifts and as per the directions of the Engineer-in-charge
of the work and including providing 2 coats of approved quality paint over
one coat of shop painting (excluding cost of earthwork and concrete)
(PWD SR 2009-10/P.No. 231/37.2)
37.3 Providing chain link fencing 50mm size of 8 guage properly stretched
between rectangular poles and fixed with suitable bolts & nuts, the free
ends shall be welded to the pole and block pipe at top and bottom as
required including cost of all materials, labour, lead and lifts and as per the Sqm 400.00
directions of the Engineer-in-charge of the work etc, complete inncluding
two coats of approved quality paint over one coat of shop paint. (PWD SR
2009-10/P.No. 231/37.3)

37.4
Providing and fixing M.S. Block pipe of 38mm dia, of heavy guage of 14
including removing the bends, cutting the pipe, and fixing pipe in between
the two verticle poles (M.S.rectangular poles) and spot welding the chain
link with M.S. block pipe including cost of all materials wastage in cutting,
m 225.00
and scaffolding wherever necessary with all lead and lift as directed by the
Engineer-in-charge of work etc., complete including two coats of approved
quality paint over one coat of shop paint. (PWD SR 2009-10/P.No.
231/37.4)

37.5 Providing barbed GI wire fencing of 12x12 guage drawn into stone pillars
or iron pillars including drawing in holes wherever necessary excluding the
m 9.30
cost of pillars but including the cost of barbed wire and bending wire etc.,
complete (PWD SR 2009-10/P.No. 231/37.5)

37.6 Providing corrugated cement asbestos Ridge sheets set in C.M 1:3 and
m 325.00
pointed with C.M. 1:3. (PWD SR 2009-10/P.No. 231/37.6)

37.7 Providing Mangalore Ridge tiles set in C.M 1:2 and pointed with C.M 1:2.
m 120.00
(PWD SR 2009-10/P.No. 231/37.7)

37.8 Fixing doors, window and ventilators in walls. (PWD SR 2009-10/P.No.


No 175.00
231/37.8)

37.9 Removing and fixing old Mangalore ridge tiles including pointing with C.M
m 328.00
1:3. (PWD SR 2009-10/P.No. 231/37.9)

37.10 Removing and fixing old Mangalore ridge tiles including pointing with C.M
m 33.00
1:3. (PWD SR 2009-10/P.No. 231/37.10)

37.11 Repairs to roof with available corrugated zinc sheets / A.C sheets with new
J bolts, screws and washes etc., on existing reeper and rafters. (PWD SR Sqm 33.00
2009-10/P.No. 232/37.11)

37.12 Repairing door and window frames with available wood to the required
Sqm 225.00
size. (PWD SR 2009-10/P.No. 232/37.12)

37.13 Repairing and fixing shutters (panelled or glazed) to doors, window


Sqm 225.00
ventilators and cupboards. (PWD SR 2009-10/P.No. 232/37.13)

37.14 Fixing old eve board with necessry screws and approved painting two
m 8.50
coats. (PWD SR 2009-10/P.No. 232/37.14)
37.15
Providing and fixing plain rolled glass 3mm thick with T.W beading of
Sqm 535.00
10mm thick. (PWD SR 2009-10/P.No. 232/37.15)

37.16 Providing and fixing 4mm thick glass panes to steel windows including T.W
beading of 10 mm thick and 2 coats of approved paints. (PWD SR 2009- Sqm 595.00
10/P.No. 232/37.16)

37.17
Easing of shutters of door (PWD SR 2009-10/P.No. 232/37.17) No 28.00

37.18 Easing of window shutters (PWD SR 2009-10/P.No. 232/37.18) No 27.00

37.19 Providing and fixing M.S bars to windows and ventilators including cutting
making holes in frame work with two coats with approved paint etc., Kgs 29.00
complete (PWD SR 2009-10/P.No. 232/37.19)

37.20 Labour charges for fixing iron bars to windows including cutting fixing and
making holes in the frame work and painting two coats with approved paint
Kgs 28.00
etc., complete (excluding the cost of iron bars) (PWD SR 2009-10/P.No.
232/37.20)

37.21 Repairs to cornice or coping or mortar band, 15 cm deep and 8 cm


Sqm 33.00
projection for damaged poriton. (PWD SR 2009-10/P.No. 232/37.21)

37.22 Removing cuddappa slab flooring and stacking the material with a lead of
Sqm 16.00
50 meters. (PWD SR 2009-10/P.No. 232/37.22)

37.23 Removing and resetting Mangalore tiles and replacing broken ones
wherever necessary (excluding cost of new tiles) (PWD SR 2009-10/P.No. Sqm 8.30
232/37.23)

37.24 Cleaning glass with chemicals (PWD SR 2009-10/P.No. 232/37.24) Sqm 5.00

37.25 Removing and refixing existing mortar and pestle stone (PWD SR 2009-
Each 89.00
10/P.No. 232/37.25)

37.26 Removing by chiselling cement joints 50mm to 80mm deep in pipes upto
Sqm 16.00
150mm dia. (PWD SR 2009-10/P.No. 232/37.26)

37.27
Labour charges for fixing plain, frosted or pin headed glass panels (Clear
Sqm 180.00
glass area) with teak wood beading. (PWD SR 2009-10/P.No. 232/37.27)

37.28
Drilling holes of 2.50 cms dia (roof/chejja/stone) (PWD SR 2009-10/P.No.
232/37.28)

37.28.1 Drilling holes of 2.50 cms dia (roof/chejja/stone) (PWD SR 2009-10/P.No.


No 42.00
232/37.28.1) in slabs upto 7.50 cms thick
37.28.2 Drilling holes of 2.50 cms dia (roof/chejja/stone) (PWD SR 2009-10/P.No.
No 51.00
232/37.28.2) in slabs upto 10 cms thick

37.29 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
exposed faces. (PWD SR 2009-10/P.No. 232/37.29)

37.29.1 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
Set 170.00
exposed faces. (PWD SR 2009-10/P.No. 232/37.29.1) 50 cms x 50 cms
x 60 cms

37.29.2 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
Set 135.00
exposed faces. (PWD SR 2009-10/P.No. 232/37.29.2) 40 cms x 40 cms
x 40 cms

37.30
Providing wall black boards in CM 1:3 with two coats of black paint
Sqm 520.00
including finishing etc., complete. (PWD SR 2009-10/P.No. 232/37.30)

37.31 Providing and fixing mortise locks heavy duty to doors. (PWD SR2009-
Each 575.00
10/P.No.233/37.31)

37.32 Providing and fixing hydraulic door closures with mounting heavy duty.
No 960.00
(PWD SR2009-10/P.No.233/37.32)

37.33 Providing and fixing hydraulic door closures Aluminium body (PWD
No 715.00
SR2009-10/P.No.233/37.33)

37.34
Cleaning of glazed tiles (PWD SR2009-10/P.No.233/37.34) Sqm 32.00

37.35 Wall bores in Brick masonry upto 45 cm thick. (PWD SR2009-


Each 52.00
10/P.No.233/37.35)

37.36
Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36)

37.36.1 Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36.1)


Each 112.00
Upto 45 cm thick.

37.36.2 Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36.2)


Each 133.00
Upto 60 to 90 cm thick.

37.36.3 Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36.3)


Each 155.00
Upto 90 to 120 cm thick.

37.37 Cutting of road surface for pipeline trenches and disposing of the
excavated stuff as directed including barricading, danger lighting etc., in Cum 133.00
the Macadam road. (PWD SR2009-10/P.No.233/37.37)
37.38 Cutting of road surface for pipeline trenches and disposing of the
excavated stuff as directed including barricading, danger lighting etc., in Cum 210.00
the Asphalt surface road. (PWD SR2009-10/P.No.233/37.38)

37.40 Cutting of road surface for pipeline trenches and disposing of the
excavated stuff as directed including barricading, danger lighting etc., in Cum 410.00
the Cement concrete road. (PWD SR2009-10/P.No.233/37.40)

37.41 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete
(PWD SR2009-10/P.No.233/37.41)

37.41.1 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 205.00
(PWD SR2009-10/P.No.233/37.41.1) 1.50 mtrs depth upto & including
3m depth.

37.41.2 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 375.00
(PWD SR2009-10/P.No.233/37.41.2) beyond 1.50 mtrs depth upto &
including 4.5m depth.

37.41.3 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 580.00
(PWD SR2009-10/P.No.233/37.41.3) beyond 3.00 mtrs depth upto &
including 4.5m depth.

37.41.4 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 910.00
(PWD SR2009-10/P.No.233/37.41.4) beyond 4.50 mtrs depth upto &
including 6.00m depth.

37.42 Dismantling Mangalore tiles roof and stacking the material within a radius
of 50 metres. (PWD SR2009-10/P.No.233/37.42)

37.42.1 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 27.00
of 50 metres. (PWD SR2009-10/P.No.233/37.42.1) with reepers

37.42.2 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 18.00
of 50 metres. (PWD SR2009-10/P.No.233/37.42.2) without reepers

37.42.3 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 24.00
of 50 metres. (PWD SR2009-10/P.No.233/37.42.2) A.C. sheet roofing.

37.43 Dismantling CI or AC rain water Pipes with fittings and clamps and
stacking the materials with a lead of 50 metres. (PWD SR2009- Sqm 7.00
10/P.No.233/37.43)
37.44 Dismanting weather proof course and removing and conveying the debris
Cum 312.00
to a distance upto 200m (PWD SR2009-10/P.No.234/37.44)

37.45 Dismantling Madras terrace jack arch roof including rafters and stacking
the materials with a lead upto 50m and removing the debries to a distance Sqm 85.00
upto 200m. (PWD SR2009-10/P.No.234/37.45)

37.46 Dismantling stone slab roofing over wooden reepers or RCC barrens
(dismantling reepers and battens to be paid for separately) including
stacking of serviceable materials and disposal of unserviceable within Sqm 100.00
200m lead (with in average thickness of 10 cms(PWD SR2009-
10/P.No.234/37.46)

37.47 Dismanting burnt brick masonry in clay mortar/lime mortar/cement mortar


and stacking the size stone within a radius of 50m and removing the debris Cum 100.00
to a distance upto 200m . (PWD SR2009-10/P.No.234/37.47)

37.48 Dismanting size stone masonry in clay mortar and stacking the size stone
within a radius of 50m and removing the debris to a distance upto 200m . Cum 118.00
(PWD SR2009-10/P.No.234/37.48)

37.49 Dismantling the tile work in floor and roof laid in cement of surki mortar
including stacking the materials with in 50 m lead of tiles thickness 10mm Sqm 17.00
to 25mm. (PWD SR2009-10/P.No.234/37.49)

37.50 Dismantling plastering and removing the debris with a lead upto 200m
Sqm 13.00
(PWD SR2009-10/P.No.234/37.50)

37.51 Dismanting cement concrete flooring or plain cement concrete work


including removing and conveying the debris to a distance upto 200m . Sqm 33.00
(within average thickness of 15 cms) (PWD SR2009-10/P.No.234/37.51)

37.52 Dismantling barbed wire or flexible wirer rope in fencing including making
m 2.75
rolls and stacking within 50m lead. (PWD SR2009-10/P.No.234/37.52)

37.53 Dismantling expanded metal or IRC fabric with weld mesh necessary
battens and beading etc., including stacking the serviceable materials Sqm 10.00
within 50m lead. (PWD SR2009-10/P.No.234/37.53)

37.54 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge


with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two
Sqm 820.00
coats approved paint etc., Complete. (Including cost of screws).(PWD
SR2009-10/P.No.234/37.54)

37.55 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge


with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two
coats approved paint etc., Complete. (Including cost of screws).(PWD Sqm 720.00
SR2009-10/P.No.234/37.55) with weld mesh 75 mm x 25 mm x 6G x
10G.
37.56 Providing and fixing satinless steel hand rails for a height of 900 mm using
m 62.50 mm dia of 16 guage for top measure and verticals at 1.50 m C/c
and 50mm dia of 16 guage stainless steel pipes of 4 rows below top
measures at equal intervels including fiixing with 500 mm dia D.I pipe
m
including cutting, wleding, bending wherever necessary with suitable caps
at top and bottom etc., complete finishing with mat/shininig finishing etc.,
complete as per technical specification and as directed by the Engineer-in-
charge of work. (PWD SR2009-10/P.No.234/37.56)

37.57 Removing and resetting of footpath slab. (PWD SR2009-


Sqm 72.00
10/P.No.234/37.57)

37.58
Removing and resetting of kerb stone(PWD SR2009-10/P.No.234/37.58) m 42.00

37.59 Supplying water storage tanks made of virgin polymer (LLDPE) with two
layers outer Black or Blue and inner White layer of approved quality and
L 6.24
make, confirming to I.S.I./ISO/SSI Specifications.(PWD SR2009-
10/P.No.234/37.59)

37.60 Providing and constructing laterite size stone masonry with stones
chistelled dressing neatly placed in layer not less than 15cm high etc., as
per approved specifications including curing, providing & removing,
scaffolding wherever necessary etc., complete including all lead, lift
loading, unloading etc., for all the materials..(PWD SR2009-
10/P.No.235/37.60)

37.60.1 For Foundation & Basement in CM 1:6 (PWD SR2009-


Cum 2150.00
10/P.No.235/37.60.1)

37.60.2
For Super Structure in CM 1:6 (PWD SR2009-10/P.No.235/37.60.2) Cum 2520.00

37.61 Supplying graded laterite metal with all lead & lift, loading & unloading etc.,
complete. (PWD SR2009-10/P.No.235/37.61)

37.61.1 Supplying graded laterite metal with all lead & lift, loading & unloading etc.,
Cum 350.00
complete. (PWD SR2009-10/P.No.235/37.61.1) 80-150m

37.61.2 Supplying graded laterite metal with all lead & lift, loading & unloading etc.,
Cum 360.00
complete. (PWD SR2009-10/P.No.235/37.61.2) 40-80m

RCC Village Name Board :


37.62
RCC Village Name Board : Supplying and fixing M20 grade RCC Village
name board including excavation in all types of soils. Top edge to be cut to
required shape foundation concrete in CC 1:3:6 with 40mm and down size
metal, plinth concrete in CC 1:2:4 with 20mm and down size metal and
exposed faces of RCC slab and poles enamel painted with two coats
including lattering complete asper detailed specifications, drawings and
direction with RCC poles of size 2.70 x 0.1625 x 0.1625 mtrs 2 nos and
board of size 1.80 x 0.68 mtr complete including providing and fixing bolt Each 9000.00
and nuts of required size for fixing board to the RCC pillars including cost
of all materials lead and lift, loading and unloading and other incidental
charges etc., complete and work is tobe carried out as per approved
design and drawing and as per the standard technical specificationn and
as per the direction of the Engineer-in-charge of the work including
providing and fixing top RCC design board with cornice work of size 1/2 x
1.80 x 0.245 x 0.075 mtr etc complete. (PWD SR2009-10/P.No. 235/37.62)

MS Cautionary Board
37.64
Supplying and fixing cautionary boards of size 90cms x 90cms x 90 cms
triangular shape made of MS Sheet of 15 G (1.60 thick) The board shall be
triangular in shape as per drawing with corner and sides rounded suitably.
The supports shall be MS angle of size ISA 65x65x65x6m. The board is
fixed to one no of MS pole made out of ISA 50x50x6mm with height of
3.65 M with necessary bolts and nuts for fixing the board to the pole
(angle) etc., complete including cost of widening for fixing to the post, cost
of posts, excavation, fixing at specified location to a design depth below
GL in CC of 1:2:4 proportion (minimum section = 1 x 0.30x 0.30x (Below Each 2200.00
GL 0.75+above GL 0.30) with necessary grip rod as shown in the drawing,
including cost of all materials lead and lift, loading & unloading and other
incidental charges etc., complete and work is tobe carried out as per
approved design and drawing and as per the standard technical
specification and as per the direction of the Engineer-in-charge of the work
including providing and fixing top RCC design board with cornice work of
size 1/2 x 1.80 x 0.245 x 0.075 mtr etc complete. (PWD SR2009-
10/P.No.236/37.64)

MS Display board
37.65 Supplying and fixing Display boards of size 1.80 M x 1.60 M made of MS
sheet of 18 G (1.25 mm thick). The board shall be rectangular in shape as
per drawing with corners framed suitable framed with MS angle of size (50
x 50 x6mm all round on four sides at the back side of the board. The board
supports with MS angle of size ISA 75x75x8mm. The board fixed to 2 Nos
of MS pole mase out of ISA 75x75x8mm with a height of 3.80 m with
necessary bolts and nuts for fixing the board to the pole (angle) etc.,
complete including cost of welding for fixing to the post, cost of posts,
excavation, fixing at specified location to a design depth below GL in CC
Each 11300.00
1:2:4 proportion (Min section = 2 x 0.30 x 0.30 x below GL 1.0M) with
necessary grip rod as shown in the drawing including cost of all materials,
labour, lead, lift fabrication welding grinding sharpening, fixing etc., and
including all lead lift loading and unloading all taxes and all incidental
charge etc., complete including painting with 2 coats of enamel paint over
a coat of primer and including lattering as specified by the department etc.,
and the work is tobe carried out as per approved design and drawing and
as per the standard technical specification and as per the direction of the
Engineer-in-charge of the Work. (PWD SR2009-10/P.No.236/37.65)
With AW of With AW of
3% 6%
3% 6%
7148.2 7356.4

0 0
5211.8 5363.6

0 0
4253.9 4377.8

0 0
3440.2 3540.4

0 0
3007.6 3095.2

0 0
2626.5 2703

0 0
2255.7 2321.4

0 0
2008.5 2067

0 0
3141.5 3233

0 0
2605.9 2681.8

0 0
2327.8 2395.6
0 0
2863.4 2946.8

0 0
2224.8 2289.6

0 0
1915.8 1971.6

0 0
2389.6 2459.2

0 0
1874.6 1929.2

0 0
4624.7 4759.4

0 0
4614.4 4748.8

0 0
4583.5 4717

0 0
3955.2 4070.4

0 0
3450.5 3551

0 0
3172.4 3264.8

0 0
2914.9 2999.8

0 0
3115.75 3206.5

0 0
2945.8 3031.6

0 0
18128 18656

0 0
13997.7 14405.4

0 0
10753.2 11066.4

0 0
9012.5 9275

0 0
2914.9 2999.8

0 0
2348.4 2416.8

0 0
2039.4 2098.8

0 0
1792.2 1844.4

71.07 73.14
0 0

0 0
0 0
0 0
86.52 89.04

0 0
121.54 125.08

0 0
104.03 107.06

0 0
156.56 161.12

0 0
329.6 339.2

0 0
484.1 498.2

0 0
324.45 333.9

0 0
695.25 715.5

0 0
741.6 763.2

0 0
70.04 72.08

0 0
41.2 42.4

0 0
139.05 143.1

0 0
854.9 879.8

0 0
360.5 371

0 0
999.1 1028.2

0 0
3.2445 3.339

0 0
1493.5 1537

0 0
1946.7 2003.4

0 0
113.3 116.6

0 0
135.96 139.92

0 0
6.901 7.102

0 0
12.154 12.508

0 0
0 0

0 0
28.84 29.68

0 0
39.14 40.28

0 0
406.85 418.7

0 0
154.5 159

0 0
0 0
0 0
0 0
0 0
272.95 280.9

0 0
104.03 107.06

0 0
53.56 55.12

0 0
41.2 42.4

0 0
209.09 215.18

0 0
64.89 66.78

0 0
157.59 162.18

21.63 22.26

0 0
0 0
0 0
0 0
4006.7 4123.4

0 0
3429.9 3529.8

0 0
3151.8 3243.6

0 0
2956.1 3042.2

0 0
4490.8 4621.6

0 0
4068.5 4187

0 0
3491.7 3593.4

0 0
58.71 60.42

0 0
76.22 78.44

0 0
5304.5 5459

0 0
4552.6 4685.2

0 0
4130.3 4250.6

0 0
3563.8 3667.6

0 0
4068.5 4187

0 0
3502 3604

0 0
5304.5 5459

0 0
4552.6 4685.2

0 0
4130.3 4250.6

0 0
350.2 360.4

0 0
360.5 371

0 0
11.124 11.448

0 0
13.081 13.462

0 0
13.081 13.462

0 0
262.65 270.3

0 0
194.67 200.34

0 0
154.5 159

0 0
803.4 826.8

0 0
142.14 146.28

0 0
208.06 214.12

0 0
226.6 233.2

0 0
174.07 179.14

0 0
216.3 222.6

0 0
545.9 561.8

0 0
154.5 159

0 0
203.94 209.88

0 0
432.6 445.2

0 0
160.68 165.36

0 0
298.7 307.4

0 0
326.51 336.02

0 0
262.65 270.3

0 0
247.2 254.4

0 0
386.25 397.5

0 0
166.86 171.72

0 0
0 0
0 0

0 0
141.11 145.22

0 0
0 0

0 0
31.93 32.86

0 0
0 0

0 0
4789.5 4929

0 0
4851.3 4992.6

0 0
25.75 26.5

0 0
0 0

0 0
4274.5 4399

0 0
0 0

0 0
4253.9 4377.8

0 0
4635 4770

0 0
122.57 126.14

0 0
55.62 57.24

0 0
0 0

0 0
278.1 286.2

0 0
358.44 368.88

0 0
346.08 356.16

0 0
1236 1272

0 0
478.95 492.9

0 0
494.4 508.8

0 0
448.05 461.1

0 0
0 0

0 0
504.7 519.4

0 0
654.05 673.1

0 0
0 0
0 0
1030 1060

0 0
1699.5 1749

0 0
1823.1 1876.2

0 0
1699.5 1749

0 0
2266 2332

0 0
2441.1 2512.2

0 0
2183.6 2247.2

0 0
2750.1 2830.2

0 0
2853.1 2936.2

0 0
2317.5 2385

0 0
2884 2968

0 0
2987 3074

0 0
3223.9 3317.8

0 0
107.12 110.24

0 0
164.8 169.6

0 0
386.25 397.5

0 0
298.7 307.4

0 0
499.55 514.1

0 0
700.4 720.8

0 0
195.7 201.4

0 0
49.44 50.88

0 0
18.54 19.08

0 0
3.502 3.604

0 0
509.85 524.7

0 0
504.7 519.4

0 0
437.75 450.5

0 0
669.5 689

0 0
453.2 466.4

0 0
0 0

0 0
277.07 285.14

0 0
215.27 221.54

0 0
215.27 221.54

0 0
0 0

0 0
422.3 434.6

0 0
494.4 508.8

0 0
33.99 34.98

0 0
45.32 46.64

0 0
0 0
0 0
2976.7 3063.4

0 0
3491.7 3593.4

0 0
3584.4 3688.8

0 0
3110.6 3201.2

0 0
3666.8 3773.6

0 0
3769.8 3879.6

0 0
3965.5 4081

0 0
5737.1 5904.2

0 0
5829.8 5999.6

0 0
6035.8 6211.6

0 0
6231.5 6413

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
509.85 524.7

0 0
545.9 561.8

0 0
478.95 492.9

0 0
504.7 519.4

0 0
0 0

0 0
0 0
0 0
0 0

0 0
0 0

0 0
0 0

0 0
3048.8 3137.6

0 0
2472 2544

0 0
1926.1 1982.2

0 0
1606.8 1653.6

0 0
2935.5 3021

0 0
427.45 439.9

0 0
2853.1 2936.2

0 0
2369 2438

0 0
61.8 63.6
0 0
2884 2968

0 0

0 0
2853.1 2936.2

0 0

0 0
2575 2650

0 0

0 0
3296 3392

0 0

0 0
3697.7 3805.4

0 0

0 0
2369 2438
0 0

0 0
3007.6 3095.2

0 0

4501.1 4632.2

0 0

0 0
4933.7 5077.4

0 0
5067.6 5215.2

5340.55 5496.1

0 0
0 0

0 0
11124 11448

0 0
7931 8162

0 0
2605.9 2681.8

0 0

0 0
1982.75 2040.5

0 0
0 0
0 0
0 0

0 0
0 0

0 0
3708 3816

0 0
3914 4028

0 0
2492.6 2565.2

0 0
3149.74 3241.48

0 0
3421.66 3521.32

0 0

0 0

0 0
535.6 551.2

0 0
360.5 371

0 0
329.6 339.2

0 0
1318.4 1356.8

0 0
695.25 715.5

0 0
269.86 277.72

0 0
5.356 5.512

0 0
257.5 265

0 0
231.75 238.5

0 0
782.8 805.6

0 0
643.75 662.5

0 0
571.65 588.3

0 0
772.5 795

0 0
303.85 312.7

0 0
339.9 349.8

0 0
381.1 392.2

0 0
417.15 429.3

0 0
406.85 418.7

0 0
463.5 477

0 0
1349.3 1388.6

0 0
1405.95 1446.9

0 0
355.35 365.7

0 0
51.5 53

0 0
679.8 699.6

0 0
23.69 24.38

0 0
0 0

0 0
2111.5 2173

0 0
62212 64024

0 0
48822 50244

0 0
39449 40598

0 0
32764.3 33718.6

0 0
2410.2 2480.4

0 0
1112.4 1144.8

0 0
875.5 901

0 0
710.7 731.4

0 0
134775.5 138701

0 0
62624 64448

0 0
49234 50668

0 0
39861 41022

0 0
5582.6 5745.2

0 0
2842.8 2925.6

0 0
2338.1 2406.2

0 0
5232.4 5384.8

0 0
2678 2756

0 0
2214.5 2279

0 0
4871.9 5013.8

0 0
2523.5 2597

0 0
2090.9 2151.8

0 0
4521.7 4653.4

0 0
2358.7 2427.4

0 0
1596.5 1643

0 0
4758.6 4897.2

0 0
2513.2 2586.4

0 0
4408.4 4536.8

0 0
2358.7 2427.4

0 0
3986.1 4102.2

0 0
2163 2226
0 0
3769.8 3879.6

0 0
2060 2120

0 0
2369 2438

0 0
2255.7 2321.4

0 0
2101.2 2162.4

0 0
2163 2226

0 0
2090.9 2151.8

0 0
2029.1 2088.2

0 0
2039.4 2098.8

0 0
1926.1 1982.2

0 0
1771.6 1823.2

0 0
5917.35 6089.7

0 0
2987 3074

0 0
2456.55 2528.1

0 0
2497.75 2570.5

0 0
5026.4 5172.8

0 0
2595.6 2671.2

0 0
2142.4 2204.8

0 0
2286.6 2353.2

0 0
4578.35 4711.7

0 0
2389.6 2459.2

0 0
1977.6 2035.2

0 0
2039.4 2098.8

0 0
1987.9 2045.8

0 0
5098.5 5247

0 0
2781 2862

0 0
2348.4 2416.8

0 0
2472 2544

0 0
4532 4664

0 0
2523.5 2597

0 0
2152.7 2215.4

0 0
2029.1 2088.2

0 0
4171.5 4293

0 0
2415.35 2485.7

0 0
2080.6 2141.2

0 0
1884.9 1939.8

0 0
3574.1 3678.2

0 0
2008.5 2067

0 0
3234.2 3328.4

0 0
1854 1908

0 0
2904.6 2989.2

0 0
1699.5 1749

0 0
4408.4 4536.8

0 0
2513.2 2586.4

0 0
2163 2226

0 0
2575 2650

0 0
1545 1590

0 0
1339 1378

0 0
679.8 699.6

0 0
473.8 487.6

0 0
345.05 355.1

0 0
1596.5 1643

0 0
211.15 217.3

0 0
0 0

0 0
2060 2120

0 0
2008.5 2067

0 0
1369.9 1409.8

0 0
1519.25 1563.5

0 0
185.4 190.8

0 0
169.95 174.9

0 0
0 0

0 0
2492.6 2565.2

0 0
2832.5 2915

0 0
1957 2014

0 0
288.4 296.8

0 0
2472 2544

0 0

0 0
3090 3180

0 0

0 0
370.8 381.6

0 0
432.6 445.2

0 0
339.9 349.8

0 0
169.95 174.9

0 0
0 0

0 0
0 0
238.96 245.92

0 0
535.6 551.2

0 0
525.3 540.6

0 0

0 0
257.5 265

0 0
499.55 514.1

0 0
715.85 736.7

0 0
787.95 810.9

0 0
18.54 19.08

0 0
77.25 79.5

0 0
721 742

0 0
793.1 816.2

0 0
0 0

0 0
231.75 238.5

0 0
355.35 365.7

0 0
484.1 498.2

0 0
525.3 540.6

0 0
545.9 561.8

0 0
576.8 593.6

0 0
618 636

0 0
664.35 683.7

0 0
803.4 826.8

0 0
149.35 153.7

0 0
251.32 258.64

0 0
278.1 286.2

0 0
301.79 310.58

0 0
314.15 323.3
0 0
355.35 365.7

0 0
401.7 413.4

0 0
442.9 455.8

0 0
484.1 498.2

0 0
220.42 226.84

0 0
355.35 365.7

0 0
417.15 429.3

0 0
478.95 492.9

0 0
489.25 503.5

0 0
561.35 577.7

0 0
643.75 662.5

0 0
721 742

0 0
808.55 832.1

0 0
468.65 482.3

0 0
566.5 583

0 0
664.35 683.7

0 0
726.15 747.3

0 0
767.35 789.7

0 0
875.5 901

0 0
999.1 1028.2

0 0
1112.4 1144.8

0 0
1225.7 1261.4

0 0
8610.8 8861.6

0 0
12854.4 13228.8

0 0
16026.8 16493.6

0 0
19055 19610

0 0
26192.9 26955.8

0 0
48811.7 50233.4

0 0
26563.7 27337.4

0 0
178.19 183.38

0 0
153.47 157.94

0 0
139.05 143.1

0 0
968.2 996.4

0 0
1277.2 1314.4

0 0
1699.5 1749

0 0
4655.6 4791.2

0 0
6077 6254

0 0
3399 3498

0 0
2317.5 2385

0 0
772.5 795

0 0
427.45 439.9

0 0
5201.5 5353

0 0
473.8 487.6

0 0
5850.4 6020.8

0 0
551.05 567.1

0 0
0 0

0 0
2811.9 2893.8

0 0
2976.7 3063.4

0 0
1030 1060

0 0
1184.5 1219

0 0
3502 3604

0 0
3368.1 3466.2

0 0
2533.8 2607.6

0 0
3337.2 3434.4

0 0
4521.7 4653.4

0 0
5459 5618

0 0
2420.5 2491

0 0
3007.6 3095.2

0 0
3584.4 3688.8

0 0
4017 4134

0 0
2472 2544

0 0
3306.3 3402.6

0 0
4274.5 4399

0 0
5706.2 5872.4

0 0
2111.5 2173

0 0
2338.1 2406.2

0 0
2832.5 2915

0 0
3419.6 3519.2

0 0
2729.5 2809

0 0
1977.6 2035.2

0 0
2245.4 2310.8
0 0
1720.1 1770.2

0 0
1658.3 1706.6

0 0
2008.5 2067

0 0
1792.2 1844.4

0 0
3017.9 3105.8

0 0
2461.7 2533.4

0 0
2770.7 2851.4

0 0
2863.4 2946.8

0 0
2369 2438

0 0
2085.75 2146.5

0 0
4985.2 5130.4

0 0
4665.9 4801.8

0 0
4161.2 4282.4

0 0
952.75 980.5

0 0
545.9 561.8

0 0
978.5 1007

0 0
515 530

0 0
1328.7 1367.4

0 0
710.7 731.4

0 0
463.5 477

0 0
504.7 519.4

0 0
618 636

0 0
525.3 540.6

0 0
298.7 307.4

0 0
278.1 286.2

0 0
267.8 275.6

0 0
169.95 174.9

0 0
278.1 286.2

0 0
226.6 233.2

0 0
144.2 148.4

0 0
618 636

0 0
494.4 508.8

0 0
432.6 445.2

0 0
566.5 583

0 0
484.1 498.2

0 0
432.6 445.2

0 0
525.3 540.6

0 0
453.2 466.4

0 0
370.8 381.6

0 0
515 530

0 0
484.1 498.2

0 0
442.9 455.8

0 0
607.7 625.4

0 0
556.2 572.4

0 0
432.6 445.2

0 0
566.5 583
0 0
525.3 540.6

0 0
484.1 498.2

0 0
412 424

0 0
360.5 371

0 0
587.1 604.2

0 0
525.3 540.6

0 0
463.5 477

0 0
566.5 583

0 0
504.7 519.4

0 0
453.2 466.4

0 0
566.5 583
0 0
442.9 455.8

0 0
484.1 498.2

0 0
360.5 371

0 0
231.75 238.5

0 0
195.7 201.4

0 0
272.95 280.9

0 0
278.1 286.2

0 0
242.05 249.1

0 0
221.45 227.9

0 0
83.43 85.86
0 0
72.1 74.2

0 0
61.8 63.6

0 0
478.95 492.9

0 0
432.6 445.2

0 0
453.2 466.4

0 0
437.75 450.5

0 0
144.2 148.4

0 0
139.05 143.1

0 0
55.62 57.24

0 0
154.5 159

0 0
0 0
0 0
257.5 265

0 0
206 212

0 0
226.6 233.2

0 0
172.01 177.02

0 0
213.21 219.42

0 0
860.05 885.1

0 0
844.6 869.2

0 0
947.6 975.2

0 0
149.35 153.7

0 0
0 0

0 0
180.25 185.5

0 0
257.5 265

0 0
0 0

0 0
226.6 233.2

0 0
278.1 286.2

0 0
0 0

0 0
51.5 53

0 0
41.2 42.4

0 0
16.48 16.96

0 0
0 0
0 0
0 0
138.02 142.04

0 0
153.47 157.94

0 0
214.24 220.48
0 0
267.8 275.6

0 0
307.97 316.94

0 0
358.44 368.88

0 0
65.92 67.84

0 0
65.92 67.84

0 0
65.92 67.84

0 0
117.42 120.84

0 0
131.84 135.68

0 0
192.61 198.22

0 0
238.96 245.92

0 0
272.95 280.9

0 0
314.15 323.3

0 0
468.65 482.3

0 0
612.85 630.7

0 0
757.05 779.1

0 0
1297.8 1335.6

0 0
255.44 262.88

0 0
401.7 413.4

0 0
1019.7 1049.4

0 0
158.62 163.24

0 0
183.34 188.68

0 0
194.67 200.34

0 0
131.84 135.68

0 0
130.81 134.62

0 0
129.78 133.56

0 0
129.78 133.56

0 0
129.78 133.56

0 0
127.72 131.44

0 0
250.29 257.58

0 0
339.9 349.8

0 0
440.84 453.68

0 0
592.25 609.5

0 0
731.3 752.6

0 0
1096.95 1128.9

0 0
2044.55 2104.1

0 0
2446.25 2517.5

0 0
249.26 256.52

0 0
406.85 418.7

0 0
540.75 556.5

0 0
162.74 167.48

0 0
195.7 201.4

0 0
233.81 240.62

0 0
303.85 312.7

0 0
360.5 371

0 0
311.06 320.12

0 0
334.75 344.5

0 0
509.85 524.7

0 0
556.2 572.4

0 0
463.5 477

0 0
587.1 604.2

0 0
638.6 657.2

0 0
906.4 932.8

0 0
963.05 991.1

0 0
1009.4 1038.8

0 0
1133 1166

0 0
391.4 402.8

0 0
515 530

0 0
643.75 662.5

0 0
767.35 789.7

0 0
865.2 890.4

0 0
1014.55 1044.1

0 0
1050.6 1081.2

0 0
65.92 67.84

0 0
79.31 81.62

0 0
86.52 89.04

0 0
94.76 97.52

0 0
121.54 125.08

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
106.09 109.18

0 0
121.54 125.08

0 0
128.75 132.5

0 0
327.54 337.08

0 0
391.4 402.8

0 0
468.65 482.3

0 0
571.65 588.3

0 0
726.15 747.3

0 0
834.3 858.6

0 0
79.31 81.62

0 0
86.52 89.04

0 0
106.09 109.18

0 0
132.87 136.74

0 0
7189.4 7398.8

0 0
0 0

0 0
272.95 280.9

0 0
339.9 349.8

0 0
473.8 487.6

0 0
690.1 710.2

0 0
875.5 901

0 0
1339 1378

0 0
231.75 238.5

0 0
0 0

0 0
113.3 116.6

0 0
144.2 148.4

0 0
195.7 201.4

0 0
0 0

0 0

180.25 185.5

0 0
226.6 233.2

0 0
288.4 296.8

0 0
360.5 371

0 0
515 530

0 0
669.5 689

0 0
0 0

0 0
216.3 222.6

0 0
257.5 265

0 0
309 318

0 0
401.7 413.4

0 0
525.3 540.6

0 0
695.25 715.5

0 0
0 0

0 0

154.5 159

0 0
206 212

0 0
257.5 265

0 0
329.6 339.2

0 0
432.6 445.2

0 0
535.6 551.2

0 0

97.85 100.7

113.3 116.6
144.2 148.4

195.7 201.4

278.1 286.2

412 424

0 0

113.3 116.6

175.1 180.2
216.3 222.6

267.8 275.6

0 0

92.7 95.4

103 106

139.05 143.1

180.25 185.5

247.2 254.4

391.4 402.8
1236 1272

1545 1590

2163 2226

3811 3922

0 0
0 0
638.6 657.2

0 0
648.9 667.8

0 0
1658.3 1706.6

0 0
1931.25 1987.5

0 0
1390.5 1431

0 0
607.7 625.4

0 0
700.4 720.8

0 0
206 212

0 0
391.4 402.8

0 0
309 318

0 0
12.36 12.72

0 0
381.1 392.2

0 0
757.05 779.1

0 0
813.7 837.4

0 0
751.9 773.8

0 0
700.4 720.8

0 0
721 742

0 0
824 848

0 0
999.1 1028.2

0 0
896.1 922.2

0 0
906.4 932.8

0 0
23.69 24.38

0 0
20.6 21.2

0 0
494.4 508.8

0 0
659.2 678.4

0 0
576.8 593.6

0 0
721 742

0 0
628.3 646.6

0 0
772.5 795

0 0
690.1 710.2

0 0
844.6 869.2

0 0
782.8 805.6

0 0
803.4 826.8

0 0
700.4 720.8

0 0
690.1 710.2

0 0
0 0

0 0
700.4 720.8

0 0
659.2 678.4

0 0
1751 1802

0 0
154.5 159

0 0
181.28 186.56

0 0
721 742

0 0
875.5 901

0 0
1833.4 1886.8

0 0
1133 1166

0 0
1060.9 1091.8

0 0
906.4 932.8

0 0
5603.2 5766.4

0 0
0 0

0 0
1967.3 2024.6

0 0
2090.9 2151.8

0 0
2909.75 2994.5

0 0
3239.35 3333.7

0 0
618 636

0 0
2945.8 3031.6

0 0
0 0
0 0

0 0
54.59 56.18

0 0
52.53 54.06

0 0
54.59 56.18

0 0
52.53 54.06

0 0
80.34 82.68

0 0
77.25 79.5

0 0
18.54 19.08

0 0
19.57 20.14

0 0
104.03 107.06

0 0
92.7 95.4

0 0
82.4 84.8

0 0
118.45 121.9

0 0
105.06 108.12

0 0
91.67 94.34

0 0
139.05 143.1

0 0
123.6 127.2

0 0
108.15 111.3

0 0
149.35 153.7

0 0
131.84 135.68

0 0
113.3 116.6

0 0
111.24 114.48

0 0
99.91 102.82

0 0
7.004 7.208

0 0
5.15 5.3

0 0
6.6435 6.837

0 0
7.931 8.162

0 0
8.755 9.01

0 0
11.742 12.084

0 0
8.755 9.01

0 0
99.91 102.82

0 0
86.52 89.04

0 0
12.36 12.72

0 0
14.42 14.84

0 0
30.9 31.8

0 0
33.99 34.98

0 0
43.26 44.52

0 0
16.995 17.49

0 0
4.635 4.77

0 0
2.06 2.12

0 0
4.635 4.77

0 0
2.472 2.544

0 0
4.12 4.24

0 0
39.14 40.28

0 0
7.21 7.42

0 0
4.12 4.24

0 0
0 0

0 0
15.862 16.324

0 0
1.03 1.06

0 0
0 0

0 0
31.93 32.86

0 0
2.163 2.226

0 0
0 0

0 0
9.785 10.07

0 0
0.515 0.53

0 0
6.695 6.89

0 0
0 0
0 0
46.35 47.7

0 0
2.575 2.65

0 0
0 0

0 0
19.055 19.61

0 0
1.03 1.06

0 0
0 0

0 0
46.35 47.7

0 0
61.8 63.6

0 0
1.751 1.802

0 0
0 0

0 0
29.87 30.74

0 0
1.339 1.378

0 0
19.57 20.14

0 0
0 0

0 0
33.99 34.98

0 0
51.5 53

0 0
12.875 13.25

0 0
0 0

0 0
19.57 20.14

0 0
27.81 28.62

0 0
13.184 13.568

0 0
26.265 27.03

0 0
17.51 18.02

0 0
32.445 33.39

0 0
23.175 23.85

0 0
26.265 27.03

0 0
0 0

0 0
52.53 54.06

0 0
30.385 31.27

0 0
0 0

0 0
32.445 33.39

0 0
30.385 31.27

0 0
0 0

0 0
49.44 50.88

0 0
23.69 24.38

0 0
0 0

0 0
25.75 26.5

0 0
23.69 24.38

0 0
80.34 82.68

0 0
41.2 42.4

0 0
42.23 43.46

0 0
20.6 21.2

0 0
21.63 22.26

0 0
13.905 14.31

0 0
11.845 12.19

0 0
22.145 22.79

0 0
20.085 20.67

0 0
20.085 20.67

0 0
51.5 53

0 0
31.93 32.86

0 0
37.08 38.16

0 0
22.66 23.32

0 0
22.145 22.79
0 0
20.085 20.67

0 0
19.055 19.61

0 0
47.895 49.29

0 0
29.87 30.74

0 0
34.505 35.51

0 0
22.145 22.79

0 0
16.48 16.96

0 0
15.45 15.9

0 0
684.95 704.9

0 0
793.1 816.2

0 0
746.75 768.5

0 0
700.4 720.8

0 0
10.3 10.6

0 0
169.95 174.9

0 0
262.65 270.3

0 0
242.05 249.1

0 0
206 212

0 0
545.9 561.8

0 0
648.9 667.8

0 0
0 0

0 0
4.3775 4.505

0 0
3.193 3.286

0 0
2.9355 3.021

0 0
2.2145 2.279

0 0
10.3 10.6

0 0
0 0

0 0
23.69 24.38

0 0
15.45 15.9

0 0
21.63 22.26

0 0
13.39 13.78

0 0
18.54 19.08

0 0
13.39 13.78

0 0
0 0

0 0
39.14 40.28

0 0
25.75 26.5
0 0
35.02 36.04

0 0
21.63 22.26

0 0
32.96 33.92

0 0
28.84 29.68

0 0
69.01 71.02

0 0
0 0

0 0
0 0

0 0
3.09 3.18

0 0
3.399 3.498

0 0
1.339 1.378

0 0
1.442 1.484

0 0
0 0

0 0
1.442 1.484

0 0
1.545 1.59

0 0
0 0

0 0
1.442 1.484

0 0
1.545 1.59

0 0
2.472 2.544

0 0
32.96 33.92

0 0
19.055 19.61
0 0
36.05 37.1

0 0
28.84 29.68

0 0
36.05 37.1

0 0
32.96 33.92

0 0
8.24 8.48

0 0
118.45 121.9

0 0
93.73 96.46

0 0
76.22 78.44

0 0
700.4 720.8

0 0
329.6 339.2

0 0
262.65 270.3

0 0
195.7 201.4

0 0
257.5 265

0 0
365.65 376.3

0 0
54.59 56.18

0 0
8291.5 8533

0 0
6756.8 6953.6

0 0
5706.2 5872.4

0 0
42.23 43.46

0 0
59.74 61.48

0 0
60.77 62.54

0 0
20.6 21.2

0 0
13.905 14.31

0 0
14.42 14.84

0 0
319.3 328.6

0 0
256.47 263.94

0 0
23.69 24.38

0 0
23.69 24.38

0 0
0 0

0 0
107.12 110.24

0 0
28.84 29.68

0 0
0 0

0 0
89.61 92.22

0 0
22.66 23.32

0 0
0 0

0 0
73.13 75.26

0 0
19.57 20.14

0 0
149.35 153.7

0 0
131.84 135.68

0 0
115.36 118.72

0 0
0 0

0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
0 0

0 0
741.6 763.2

0 0
643.75 662.5

0 0
576.8 593.6

0 0
515 530

0 0
0 0

0 0
#VALUE! #VALUE!

0 0
104.03 107.06

0 0
209.09 215.18

0 0
515 530

0 0
865.2 890.4

0 0
2080.6 2141.2

126.69 130.38

0 0
221.45 227.9

0 0
432.6 445.2

0 0
834.3 858.6

0 0
8961 9222

0 0
3.399 3.498

0 0
5.15 5.3

0 0
27089 27878

0 0
36256 37312

0 0
20239.5 20829

0 0
24565.5 25281

0 0
185.4 190.8

0 0
221.45 227.9

0 0
576.8 593.6

0 0
314.15 323.3

0 0
504.7 519.4

0 0
113.3 116.6
0 0
149.35 153.7

0 0
99.91 102.82

0 0
92.7 95.4

0 0
128.75 132.5

0 0
149.35 153.7

0 0
113.3 116.6

0 0
107.12 110.24

0 0
99.91 102.82

0 0
113.3 116.6

0 0
257.5 265

0 0
669.5 689

0 0
515 530

0 0
4.635 4.77

0 0
0.618 0.636

0 0
20.6 21.2

0 0
251.32 258.64

0 0
53.045 54.59

0 0
7.725 7.95

0 0
92.7 95.4

0 0
125.66 129.32

0 0
215.27 221.54

0 0
339.9 349.8

0 0
242.05 249.1

0 0
128.75 132.5

0 0
659.2 678.4

0 0
36.05 37.1

0 0
6.695 6.89

0 0
10.094 10.388

0 0
180.25 185.5

0 0
109.18 112.36

0 0
21.63 22.26

0 0
22.66 23.32

0 0
61.8 63.6

0 0
88.58 91.16

0 0
81.37 83.74

0 0

0 0

#VALUE! #VALUE!
#VALUE! #VALUE!
0 0
45.32 46.64

0 0
61.8 63.6

0 0
56.65 58.3

0 0
86.52 89.04

0 0
236.9 243.8

0 0
412 424

0 0
324.45 333.9

0 0
623.15 641.3

0 0
91.67 94.34

0 0
128.75 132.5

0 0
0 0
65.92 67.84

0 0
0 0
112.27 115.54

0 0
0 0
303.85 312.7

0 0
0 0

33.99 34.98

0 0
0 0

45.32 46.64

0 0
0 0
187.46 192.92

0 0
0 0
386.25 397.5

0 0
339.9 349.8

0 0
0 0
39.14 40.28

0 0
0 0
35.02 36.04

0 0
0 0
82.4 84.8

0 0
0 0
143.17 147.34

0 0
28.84 29.68

0 0
179.22 184.44

0 0
39.14 40.28

0 0
319.3 328.6

0 0
453.2 466.4

0 0
247.2 254.4

0 0
70.04 72.08

0 0
0 0
1.854 1.908

0 0
2.2145 2.279

0 0
22.66 23.32

0 0
0.515 0.53
0 0
0 0
108.15 111.3

0 0
0 0

40.17 41.34

0 0
0 0
16.48 16.96

0 0
60.77 62.54

0 0
0 0
45.32 46.64

0 0
35.02 36.04

0 0
0 0
91.67 94.34

0 0
0 0
53.56 55.12

0 0
0 0
458.35 471.7

0 0
0 0
146.26 150.52

0 0
0 0
2173.3 2236.6

0 0
0 0
1.133 1.166

0 0
0 0
79.31 81.62

0 0
120.51 124.02

0 0
216.3 222.6
0 0
0 0
13.39 13.78

0 0
27.81 28.62

0 0
19.57 20.14

0 0
13.39 13.78

0 0
11.33 11.66

0 0
30.9 31.8

0 0
19.57 20.14

0 0
1.648 1.696

0 0
0 0
11.33 11.66

0 0

2.8325 2.915

0 0

0 0

190.55 196.1

0 0
0 0

67.98 69.96

0 0

0 0

0 0
0 0
37.08 38.16

0 0

0 0

3.09 3.18

0 0
49.44 50.88

0 0
24.72 25.44

0 0
5.562 5.724

0 0
23.69 24.38

0 0
20.6 21.2

0 0
77.25 79.5

0 0
4.12 4.24

0 0
2.2145 2.279

0 0
15.965 16.43

0 0
19.57 20.14

0 0
6.695 6.89

0 0
8.24 8.48

0 0
0 0
0 0

35.02 36.04

0 0
0 0
40.17 41.34

0 0
78.28 80.56

0 0
0 0

11.33 11.66

0 0
0 0
86.52 89.04

0 0
0 0

14.42 14.84

0 0
0 0

72.1 74.2

0 0
0 0
61.8 63.6

0 0
87.55 90.1

0 0
0 0

19.57 20.14

0 0
91103.5 93757

0 0
0 0

453.2 466.4

0 0
0 0
7.21 7.42

0 0
0 0

185.4 190.8

0 0
0 0
1112.4 1144.8

0 0
0 0
185.4 190.8

0 0
0 0
1246.3 1282.6

0 0
0 0
24.72 25.44

0 0
0 0
252.35 259.7

0 0
540.75 556.5

0 0
0 0
5778.3 5946.6

0 0
0 0
1606.8 1653.6

0 0
0 0
2111.5 2173

0 0
0 0
52942 54484

0 0
0 0

0 0
#VALUE! #VALUE!
#VALUE! #VALUE!
0 0
999.1 1028.2

0 0
1617.1 1664.2

0 0
1627.4 1674.8

0 0
0 0

0 0
1040.3 1070.6

0 0
1030 1060

0 0
916.7 943.4

0 0
0 0

0 0
1060.9 1091.8

0 0
947.6 975.2

0 0
824 848

0 0
0 0

0 0

0 0
1153.6 1187.2

0 0
1081.5 1113

0 0
952.75 980.5

0 0
0 0
293.55 302.1

0 0
283.25 291.5

0 0
0 0
0 0
360.5 371

0 0
0 0
782.8 805.6

0 0
0 0

0 0

0 0
1812.8 1865.6

0 0
1431.7 1473.4

0 0
0 0
1.854 1.908

0 0
0 0
1019.7 1049.4

0 0
0 0
0 0

0 0
1483.2 1526.4

0 0
1349.3 1388.6

0 0
1627.4 1674.8

0 0
1416.25 1457.5

0 0
0 0

0 0
1411.1 1452.2

0 0
1287.5 1325

0 0
1555.3 1600.6

0 0
1349.3 1388.6

0 0

0 0
149.35 153.7

0 0
0 0

0 0
17.51 18.02

0 0
0 0
1163.9 1197.8

0 0
0 0

81.37 83.74

0 0
0 0

100.94 103.88

0 0
0 0
551.05 567.1

0 0
0 0
1354.45 1393.9

0 0
1400.8 1441.6

0 0
1457.45 1499.9

0 0
1514.1 1558.2

0 0
0 0
211.15 217.3

0 0
0 0
0 0

0 0
0 0

0 0
0 0

#VALUE! #VALUE!
0 0
0 0
7.21 7.42

0 0
1.751 1.802

0 0
59.74 61.48

0 0
0 0
51.5 53

0 0
73.13 75.26

0 0
0 0
20.6 21.2

0 0
17.51 18.02

0 0
26.78 27.56

0 0
35.02 36.04

0 0
7.725 7.95

0 0
0 0
0 0

0 0
4573.2 4706.4

0 0
4665.9 4801.8

0 0
257.5 265

0 0
4573.2 4706.4

0 0
0 0
252.35 259.7

0 0
334.75 344.5

0 0
0 0
225.57 232.14

0 0
0 0
6592 6784

0 0
5541.4 5702.8

0 0
5665 5830

0 0
0 0
0 0
0 0
5742.25 5909.5

0 0
5871 6042

0 0
5603.2 5766.4

0 0
5726.8 5893.6

0 0
5562 5724
0 0

5685.6 5851.2

0 0

0 0

0 0
6190.3 6370.6

0 0
6180 6360

0 0
0 0
0 0
0 0
6210.9 6391.8

0 0
6360.25 6545.5

0 0
6077 6254

0 0
6221.2 6402.4

0 0
0 0

0 0
6720.75 6916.5

0 0
6710.45 6905.9

0 0
0 0
473.8 487.6

0 0
576.8 593.6

0 0

0 0
84.46 86.92

0 0
55.62 57.24

0 0
59.74 61.48

0 0
47.38 48.76

0 0
0 0
89.61 92.22

0 0
95.79 98.58

0 0
0 0

0 0
92.7 95.4

0 0
101.97 104.94

0 0
86.52 89.04

0 0
105.06 108.12

0 0
0 0
112.27 115.54

0 0
122.57 126.14
0 0
104.03 107.06

0 0
112.27 115.54

0 0
116.39 119.78

0 0
125.66 129.32

0 0
114.33 117.66

0 0
115.36 118.72

0 0
0 0
97.85 100.7

0 0
0 0
0 0

0 0
43.26 44.52

0 0
32.96 33.92

0 0
32.96 33.92

0 0
0 0
360.5 371

0 0
0 0

4449.6 4579.2

0 0
0 0
24.72 25.44

0 0
3.914 4.028

0 0
0 0
7632.3 7854.6

0 0
7622 7844

0 0
7519 7738

0 0
7498.4 7716.8

0 0
0 0
5531.1 5692.2

0 0
0 0
48.41 49.82

0 0
52.53 54.06

0 0
32.96 33.92

0 0
36.05 37.1

0 0
0 0
47.38 48.76

0 0
32.96 33.92

0 0
19.57 20.14

0 0
0 0
44.29 45.58

0 0
53.56 55.12

0 0
70.04 72.08

0 0
118.45 121.9

0 0
0 0
5067.6 5215.2

0 0
6901 7102

0 0
7745.6 7971.2

0 0
0 0

0 0
2369 2438

0 0
5047 5194

0 0
2657.4 2734.8

0 0
0 0
2188.75 2252.5

0 0
0 0
4660.75 4796.5

0 0
0 0

0 0
4583.5 4717
0 0

4171.5 4293

0 0
0 0
437.75 450.5

0 0
545.9 561.8

0 0
60.77 62.54

0 0
3651.35 3757.7

0 0
0 0
0 0

0 0
#VALUE! #VALUE!
#VALUE! #VALUE!
0 0
40.17 41.34

0 0
0 0

0 0
1555.3 1600.6

0 0
1503.8 1547.6

0 0
1524.4 1568.8

0 0
1565.6 1611.2

0 0
1524.4 1568.8

0 0
1545 1590

0 0
1606.8 1653.6

0 0
1874.6 1929.2
0 0
2183.6 2247.2

0 0
72573.8 74687.6

0 0
2575 2650

0 0
0 0
46.35 47.7

0 0
0 0

0 0
40.17 41.34

0 0
46.35 47.7

0 0
0.412 0.424

0 0
0.2575 0.265

0 0
92.7 95.4

0 0
85.49 87.98

0 0
66.95 68.9

0 0
63.86 65.72

0 0
401.7 413.4

0 0
0 0
2286.6 2353.2
0 0
1442 1484

0 0
370.8 381.6

0 0
345.05 355.1

0 0
288.4 296.8

0 0
0 0
185.4 190.8

0 0
345.05 355.1

0 0
494.4 508.8
0 0
906.4 932.8

0 0
638.6 657.2

0 0

0 0
2317.5 2385

0 0
1926.1 1982.2

0 0
3038.5 3127

0 0
1874.6 1929.2

0 0
0 0
4738 4876

0 0
710.7 731.4

0 0
0 0
11144.6 11469.2

0 0

7313 7526

0 0
0 0
1266.9 1303.8

0 0
2399.9 2469.8

0 0
3553.5 3657

0 0

0 0
70040 72080

0 0
0 0
638.6 657.2

0 0
700.4 720.8

0 0
1236 1272

0 0
0 0
272.95 280.9

0 0
0 0
494.4 508.8

0 0
0 0
2142.4 2204.8

0 0
0 0
2235.1 2300.2

0 0
0 0
3605 3710

0 0
4717.4 4854.8

0 0
10454.5 10759

0 0
0 0
937.3 964.6

0 0
0 0
236.9 243.8

0 0
112.27 115.54

0 0
17.51 18.02

0 0
0 0

0 0
#VALUE! #VALUE!
#VALUE! #VALUE!
0 0
14111 14522

0 0
14059.5 14469

0 0
4284.8 4409.6
0 0
7024.6 7229.2

0 0
9012.5 9275

0 0
0 0
3563.8 3667.6

0 0
5649.55 5814.1

0 0
8260.6 8501.2

0 0
1632.55 1680.1

0 0

2719.2 2798.4

0 0
4521.7 4653.4

0 0
1133 1166
0 0
1802.5 1855

0 0
3409.3 3508.6

0 0
4727.7 4865.4

0 0

5397.2 5554.4

0 0
0 0
3841.9 3953.8

0 0
3903.7 4017.4

0 0
4202.4 4324.8

0 0
4284.8 4409.6

0 0
4248.75 4372.5

0 0
4326 4452

0 0
4346.6 4473.2

0 0
4429 4558

0 0
0 0
3368.1 3466.2

0 0
0 0

44856.5 46163

0 0
44393 45686

0 0
0 0

0 0
#VALUE! #VALUE!
#VALUE! #VALUE!
0 0
0 0
40633.5 41817

0 0
265894.5 273639

0 0
1802.5 1855

0 0
0 0
64086.6 65953.2

0 0
0 0
0 0

0 0
4727.7 4865.4

0 0
5139.7 5289.4

0 0
5283.9 5437.8

0 0
3944.9 4059.8

0 0
4264.2 4388.4

0 0
4336.3 4462.6

0 0
4645.3 4780.6

0 0
4707.1 4844.2

0 0
4686.5 4823

0 0
4738 4876

0 0
4841 4982

0 0
4861.6 5003.2

0 0
4449.6 4579.2

0 0
4192.1 4314.2

0 0
4655.6 4791.2

0 0
4398.1 4526.2

0 0
5273.6 5427.2

0 0
4439.3 4568.6

0 0
5376.6 5533.2

0 0
4521.7 4653.4

0 0
0 0

4253.9 4377.8

0 0
0 0

0 0
4449.6 4579.2

0 0
5273.6 5427.2

0 0
3584.4 3688.8

0 0
3883.1 3996.2

0 0
4223 4346

0 0
4253.9 4377.8

0 0
4676.2 4812.4

0 0
3883.1 3996.2

0 0
4439.3 4568.6

0 0
4284.8 4409.6

0 0
4470.2 4600.4

0 0
4284.8 4409.6

0 0
4532 4664

0 0
4377.5 4505

0 0
4573.2 4706.4

0 0
0 0
1184.5 1219

0 0
1627.4 1674.8

0 0
1699.5 1749

0 0
2224.8 2289.6

0 0
2070.3 2130.6

0 0
2523.5 2597

0 0
2121.8 2183.6

0 0
2781 2862

0 0
0 0

0 0
2472 2544

0 0
2956.1 3042.2

0 0
5469.3 5628.6

0 0

4964.6 5109.2

0 0
11680.2 12020.4

0 0
13523.9 13917.8

0 0

2616.2 2692.4

0 0
2533.8 2607.6

0 0
1627.4 1674.8

0 0
3893.4 4006.8

0 0
2224.8 2289.6

0 0
3986.1 4102.2

0 0

2719.2 2798.4

0 0
4264.2 4388.4

0 0
2894.3 2978.6

0 0
4583.5 4717

0 0
3347.5 3445

0 0
4738 4876

0 0
5541.4 5702.8

0 0
9939.5 10229

0 0

13369.4 13758.8

0 0
23381 24062

0 0
3141.5 3233

0 0
5242.7 5395.4

0 0
7127.6 7335.2

0 0

5551.7 5713.4

0 0
6159.4 6338.8

0 0
7158.5 7367

0 0
7848.6 8077.2

0 0
17407 17914

0 0
38789.8 39919.6

0 0
8724.1 8978.2

0 0
0 0
7148.2 7356.4

0 0
8930.1 9190.2

0 0
9270 9540

0 0
10681.1 10992.2

0 0
11762.6 12105.2

0 0
26028.1 26786.2

0 0

56444 58088

0 0
12257 12614

0 0
49398.8 50837.6

0 0
1009.4 1038.8

0 0
59225 60950

0 0

0 0
262.65 270.3

0 0

211.15 217.3

0 0
484.1 498.2

0 0
406.85 418.7

0 0

0 0

0 0
61.8 63.6

0 0
80.34 82.68
0 0

107.12 110.24

0 0

88.58 91.16

0 0
114.33 117.66

0 0
142.14 146.28

0 0

37.08 38.16

0 0
42.23 43.46

0 0
51.5 53

0 0

0 0
89.61 92.22

0 0
47.38 48.76

0 0

0 0
245.14 252.28

0 0

0 0
280.16 288.32

0 0

0 0
302.82 311.64

0 0
232.78 239.56

0 0
70.04 72.08
0 0

0 0

1143.3 1176.6

0 0
0 0

154.5 159

0 0
3944.9 4059.8

0 0
1014.55 1044.1

0 0
0 0
3136.35 3227.7

0 0
0 0
3831.6 3943.2

0 0
3172.4 3264.8

0 0
0 0
2224.8 2289.6

0 0
2214.5 2279

0 0
0 0
3728.6 3837.2

0 0
4037.6 4155.2

0 0
4099.4 4218.8

0 0
4099.4 4218.8

0 0
4150.9 4271.8

0 0
3821.3 3932.6

0 0
4377.5 4505

0 0
4212.7 4335.4

0 0
4439.3 4568.6

0 0
4274.5 4399

0 0
4408.4 4536.8

0 0
4233.3 4356.6

0 0
4449.6 4579.2

0 0
4274.5 4399

0 0
4532 4664

4356.9 4483.8

0 0
0 0

0 0
6509.6 6699.2

0 0
29.87 30.74

0 0
79.31 81.62

0 0
0 0
2204.2 2268.4

0 0
2214.5 2279

0 0
2719.2 2798.4

0 0
0 0
0 0

0 0
3934.6 4049.2

0 0
4264.2 4388.4

0 0
4635 4770

0 0
4799.8 4939.6

0 0
5016.1 5162.2

0 0
4665.9 4801.8
0 0
4841 4982

0 0
5067.6 5215.2

0 0
4326 4452

0 0
4511.4 4642.8

0 0
4686.5 4823

0 0
4707.1 4844.2

0 0
4861.6 5003.2

0 0
5098.5 5247

0 0
4727.7 4865.4

0 0
4861.6 5003.2

0 0
5047 5194

0 0
4830.7 4971.4

0 0
4944 5088

0 0
5098.5 5247

0 0
0 0
44949.2 46258.4

0 0
44094.3 45378.6

0 0
0 0
174.07 179.14

0 0
281.19 289.38

0 0
1096.95 1128.9

0 0
0 0
880.65 906.3

0 0
0 0
87653 90206

0 0
0 0

0 0
87653 90206

0 0
0.6695 0.689

0 0
87601.5 90153

0 0
87704.5 90259

0 0
0 0

0 0
0 0

0 0
4676.2 4812.4

0 0
4871.9 5013.8

0 0
5067.6 5215.2

0 0
0 0
0 0

0 0
4877.05 5019.1

0 0
5072.75 5220.5

0 0
5263.3 5416.6

0 0
0 0
0 0
0 0
4480.5 4611

0 0
4665.9 4801.8

0 0
4851.3 4992.6

0 0
0 0
0 0

0 0
4665.9 4801.8

0 0
4851.3 4992.6

0 0
5047 5194

0 0
0 0
0 0

0 0
5108.8 5257.6

0 0
5325.1 5480.2

0 0
5541.4 5702.8

0 0
0 0
0 0

0 0
5325.1 5480.2

0 0
5541.4 5702.8

0 0
5747.4 5914.8

0 0
0 0
0 0

0 0
4913.1 5056.2

0 0
5119.1 5268.2

0 0
5325.1 5480.2

0 0
0 0
0 0

0 0
5119.1 5268.2

0 0
5325.1 5480.2

0 0
5531.1 5692.2

0 0
0 0
0 0

0 0
5180.9 5331.8

0 0
5397.2 5554.4

5613.5 5777

0 0
0 0
0 0

0 0
5397.2 5554.4

0 0
5613.5 5777

0 0
5829.8 5999.6

0 0
0 0
0 0

0 0
4974.9 5119.8
0 0
5180.9 5331.8

0 0
5386.9 5543.8

0 0
0 0
0 0

0 0
5180.9 5331.8

0 0
5386.9 5543.8

0 0
5592.9 5755.8

0 0
0 0
0 0

0 0
5201.5 5353

0 0
5428.1 5586.2

0 0
5644.4 5808.8

0 0
0 0
0 0

0 0
5428.1 5586.2

0 0
5644.4 5808.8

0 0
5871 6042

0 0
0 0
0 0

0 0
6087.3 6264.6

0 0
6530.2 6720.4

0 0
6973.1 7176.2

0 0
0 0
0 0

0 0
4995.5 5141

0 0
5211.8 5363.6

0 0
5428.1 5586.2

0 0
0 0
0 0

0 0
5211.8 5363.6

0 0
5428.1 5586.2

0 0
5634.1 5798.2

0 0
0 0
0 0

0 0
5850.4 6020.8

0 0
6272.7 6455.4

0 0
6695 6890

0 0
0 0
0 0

0 0
5500.2 5660.4

0 0
5634.1 5798.2

0 0
5840.1 6010.2

0 0
0 0
0 0

0 0
5634.1 5798.2

0 0
5840.1 6010.2

0 0
6035.8 6211.6

0 0
0 0
0 0

0 0
5191.2 5342.4

0 0
5397.2 5554.4

0 0
5603.2 5766.4

0 0
0 0

0 0

0 0
5397.2 5554.4

0 0
5603.2 5766.4

0 0
5819.5 5989

0 0
0 0

0 0

0 0
6035.8 6211.6

0 0
6458.1 6646.2

0 0
6880.4 7080.8

0 0
0 0
0 0

0 0
5356 5512

0 0
5582.6 5745.2

0 0
5798.9 5967.8

0 0
0 0

0 0

0 0
5582.6 5745.2

0 0
5798.9 5967.8

0 0
6025.5 6201

0 0
0 0

0 0

0 0
6252.1 6434.2

0 0
6695 6890

0 0
7148.2 7356.4

0 0
0 0

0 0

0 0
6427.2 6614.4

0 0
6880.4 7080.8

0 0
7343.9 7557.8

0 0
0 0
0 0

0 0
6756.8 6953.6

0 0
7251.2 7462.4

0 0
7735.3 7960.6

0 0
0 0
45505.4 46830.8

0 0
0 0
150277 154654

0 0
0 0
7838.3 8066.6

0 0
0 0

478.95 492.9

0 0
1102.1 1134.2

0 0
0 0
4099.4 4218.8

0 0
0 0
957.9 985.8

0 0
478.95 492.9

0 0
4099.4 4218.8

0 0
0 0
2461.7 2533.4

0 0
4521.7 4653.4

0 0
648.9 667.8

0 0
0 0
88.58 91.16

0 0
0 0
2224.8 2289.6

0 0
4006.7 4123.4

0 0
0 0
509.85 524.7

0 0
0 0
1220.55 1256.1

0 0
2255.7 2321.4

0 0
0 0
0 0
1143.3 1176.6

0 0
0 0
1993.05 2051.1

0 0
128.75 132.5

0 0
679.8 699.6

0 0
46.35 47.7

0 0
0 0
824 848

0 0
0 0
15594.2 16048.4

0 0
0 0
18117.7 18645.4

0 0
0 0
14935 15370

0 0
0 0
6695 6890

0 0
8054.6 8289.2

0 0
0 0

0 0
188.49 193.98

0 0
0 0
1205.1 1240.2

0 0
1194.8 1229.6

0 0
2410.2 2480.4

0 0
1184.5 1219

0 0
0 0
4068.5 4187

0 0
7838.3 8066.6

0 0
0 0
16459.4 16938.8

0 0
303.85 312.7

0 0
0 0
29.87 30.74

0 0
0 0

59.74 61.48

0 0
48.41 49.82

0 0
535.6 551.2

0 0
53.56 55.12

0 0
154.5 159

0 0
187.46 192.92

0 0
612.85 630.7

0 0
334.75 344.5

0 0
417.15 429.3

0 0
177.16 182.32

0 0
127.72 131.44

0 0
525.3 540.6

0 0
373684 384568

0 0
271302 279204

0 0
241741 248782
0 0
0 0

0 0
18437 18974

0 0
15707.5 16165

0 0
2636.8 2713.6

0 0
1308.1 1346.2

0 0
2121.8 2183.6

0 0
2492.6 2565.2

0 0
252.35 259.7

0 0
141.11 145.22

0 0
221.45 227.9

0 0
0 0

0 0
3043.65 3132.3

0 0
4892.5 5035

0 0
5067.6 5215.2

0 0
9826.2 10112.4

0 0
10176.4 10472.8

0 0
0 0

0 0
1143.3 1176.6

0 0
1751 1802

0 0
2338.1 2406.2

0 0
3759.5 3869

0 0
3872.8 3985.6

0 0
5829.8 5999.6

0 0
0 0

0 0
396.55 408.1

0 0
530.45 545.9

0 0
787.95 810.9

0 0
1153.6 1187.2

0 0
1781.9 1833.8

0 0
2482.3 2554.6

0 0
3120.9 3211.8

0 0
4047.9 4165.8

0 0
0 0
0 0
55.62 57.24

0 0
0 0
14.42 14.84

0 0
5.459 5.618

0 0
103 106

0 0
105.06 108.12

0 0
262.65 270.3

0 0
267.8 275.6

0 0
0 0
2.472 2.544

0 0
0 0
0.412 0.424

0 0
0 0
355.35 365.7

0 0
0 0
49.44 50.88

0 0
0 0
18.54 19.08

0 0
0 0
9.476 9.752

0 0
0 0
49.44 50.88

0 0

0 0

252.35 259.7

0 0
375.95 386.9

0 0
1205.1 1240.2

0 0

0 0

0 0

0 0

43.26 44.52

0 0

57.68 59.36

0 0

489.25 503.5

0 0
412 424

0 0

231.75 238.5

0 0

9.579 9.858

0 0

334.75 344.5

0 0

123.6 127.2

0 0

180.25 185.5

0 0

337.84 347.68

0 0

33.99 34.98

0 0

33.99 34.98

0 0

231.75 238.5

0 0

231.75 238.5

0 0

8.755 9.01

0 0
551.05 567.1

0 0
612.85 630.7

0 0

28.84 29.68

0 0

27.81 28.62

0 0

29.87 30.74

0 0

28.84 29.68

0 0

33.99 34.98

0 0

16.48 16.96

0 0

8.549 8.798

0 0

5.15 5.3
0 0

91.67 94.34

0 0

16.48 16.96

0 0

185.4 190.8

0 0

0 0

0 0

43.26 44.52

0 0
52.53 54.06

0 0

0 0

0 0

175.1 180.2

0 0

139.05 143.1

0 0

535.6 551.2

0 0

592.25 609.5

0 0

988.8 1017.6

0 0

736.45 757.9

0 0

32.96 33.92

0 0

53.56 55.12

0 0

0 0

0 0
115.36 118.72

0 0
136.99 140.98

0 0
159.65 164.3

0 0
136.99 140.98

0 0
216.3 222.6

0 0

422.3 434.6

0 0

0 0

0 0

211.15 217.3

0 0

386.25 397.5

0 0

597.4 614.8

0 0

937.3 964.6

0 0

0 0

0 0

27.81 28.62

0 0

18.54 19.08

0 0

24.72 25.44

0 0

7.21 7.42

0 0
321.36 330.72

0 0

87.55 90.1

0 0

103 106

0 0

103 106

0 0
121.54 125.08

0 0
17.51 18.02

0 0

13.39 13.78

0 0

33.99 34.98

0 0

2.8325 2.915

0 0

10.3 10.6

0 0

844.6 869.2

0 0

741.6 763.2

0 0
0 0

0 0

74.16 76.32

0 0

43.26 44.52

0 0

6.4272 6.6144

0 0

0 0

0 0

2214.5 2279

0 0

2595.6 2671.2

0 0

0 0

0 0

360.5 371

0 0

370.8 381.6

0 0

0 0
9270 9540

0 0

0 0

2266 2332

0 0

0 0

11639 11978

0 0
MORTOR
2009-2010
Sl. No. Description Rate
Unit
Rs. Ps.
1.1 KSRB 0.5-1.1 : Providing cement mortar of mix 1:1 (1 cement : 1 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 8238.00
12/P.No.2/1.1)

1.2 KSRB 0.5-1.2 : Providing cement mortar of mix 1:2 (1 cement : 2 sand)
including cost all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 6121.00
12/P.No.2/1.2)

1.3 KSRB 0.5-1.3 : Providing cement mortar of mix 1:3 (1 cement : 3 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 5065.00
12/P.No.2/1.3)

1.4 KSRB 0.5-1.4 : Providing cement mortar of mix 1:4 (1 cement : 4 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 4151.00
12/P.No.2/1.4)

1.5 KSRB 0.5-1.5 : Providing cement mortar of mix 1:5 (1 cement : 5 sand)
including cost of all materials, labour charges, HOM of Machinery complete
as per Specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 3659.00
12/P.No.2/1.5)

1.6 KSRB 0.5-1.6 : Providing cement mortar of mix 1:6 (1 cement : 6 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 3237.00
12/P.No.2/1.6)

1.7 KSRB 0.5-1.7 : Providing cement mortar of mix 1:8 (1 cement : 8 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 2815.00
12/P.No.2/1.7)

1.8 KSRB 0.5-1.8 : Providing cement mortar of mix 1:10 (1 cement : 10 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 (PWD SR 2011- Cum 2534.00
12/P.No.2/1.8)

1.9 KSRB 0.5-2.1 : Providing lime mortar of mix 1:1 (1 lime putty : 1 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 (PWD SR 2011- Cum 3426.00
12/P.No.2/1.9)
1.10 KSRB 0.5-2.2 : Providing lime mortar of mix 1:2 (1 lime putty : 2 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 (PWD SR 2011- Cum 2988.00
12/P.No.2/1.10)

1.11 KSRB 0.5-2.3 : Providing lime mortar of mix 1:3 (1 lime putty : 3 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 (PWD SR 2011- Cum 2773.00
12/P.No.2/1.11)

1.12 KSRB 0.5-3.1 : Providing lime surkhi mortar of mix 1:1 (1 lime putty : 1
surkhi) including cost of all materials, labour charges, HOM of machinery
complete as per specifications. Specification No. KBS (PWD SR 2011- Cum 2837.00
12/P.No.2/1.12)

1.13 KSRB 0.5-3.2 : Providing lime surkhi mortar of mix 1:2 (1 lime putty : 2
surkhi) including cost of all materials, labour charges, HOM of machinery
complete as per specifications. Specification No. KBS (PWD SR 2011- Cum 2203.00
12/P.No.2/1.13)

1.14 KSRB 0.5-3.3 : Providing lime surkhi mortar of mix 1:3 (1 lime putty : 3
surkhi) including cost of all materials, labour charges, HOM of machinery
complete as per specifications. Specification No. KBS (PWD SR 2011- Cum 1888.00
12/P.No.2/1.14)

1.15 KSRB 0.5-4.1 : Providing lime surkhi sand mortar of mix 1:1:1 (1 lime putty
: 1 surkhi : 1 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS (PWD Cum 2563.00
SR 2011-12/P.No.2/1.15)

1.16 KSRB 0.5-4.2 : Providing lime surkhi sand mortar of mix 1:1:2 (1 lime putty
: 1 surkhi : 2 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS (PWD Cum 2023.00
SR 2011-12/P.No.2/1.16)

1.17 KSRB 0.5-5.1 : Providing Cement mortar with stone dust of mix 1:2 (1
cement : 2 stone dust) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS (PWD Cum 5235.00
SR 2011-12/P.No.2/1.17)

1.18 KSRB 0.5-6.1 : Providing Cement lime Mortar of mix 1:1:3 (1 cement : 1
lime putty : 3 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 5319.00
(PWD SR 2011-12/P.No.3/1.18)

1.19 KSRB 0.5-6.2 : Providing Cement lime Mortar of mix 1:1:4 (1 cement : 1
lime putty : 4 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 5356.00
(PWD SR 2011-12/P.No.3/1.19)
1.20 KSRB 0.5-6.3 : Providing Cement lime Mortar of mix 1:1:5 (1 cement : 1
lime putty : 5 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 4675.00
(PWD SR 2011-12/P.No.3/1.20)

1.21 KSRB 0.5-6.4 : Providing Cement lime Mortar of mix 1:1:6 (1 cement : 1
lime putty : 6 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 4122.00
(PWD SR 2011-12/P.No.3/1.21)

1.22 KSRB 0.5-6.5 : Providing Cement lime Mortar of mix 1:1:7 (1 cement : 1
lime putty : 7 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3824.00
(PWD SR 2011-12/P.No.3/1.22)

1.23 KSRB 0.5-6.6 : Providing Cement lime Mortar of mix 1:1:8 (1 cement : 1
lime putty : 8 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3545.00
(PWD SR 2011-12/P.No.3/1.23)

1.24 KSRB 0.5-6.7 : Providing Cement lime Mortar of mix 1:2:9 (1 cement : 2
lime putty : 9 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3715.00
(PWD SR 2011-12/P.No.3/1.24)

1.25 KSRB 0.5-6.8 : Providing Cement lime Mortar of mix 1:3:12 (1 cement : 3
lime putty : 12 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 3518.00
(PWD SR 2011-12/P.No.3/1.25)

1.26 KSRB 0.5-7.1 : Providing white cement mortar with marble dust of mix 1:2
(1 white cement : 2 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 12649.00
No. KBS (PWD SR 2011-12/P.No.3/1.26)

1.27 KSRB 0.5-7.2 : Providing white cement mortar with marble dust of mix 1:3
(1 white cement : 3 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 9874.00
No. KBS (PWD SR 2011-12/P.No.3/1.27)

1.28 KSRB 0.5-7.3 : Providing white cement mortar with marble dust of mix 1:4
(1 white cement : 4 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 12649.00
No. KBS (PWD SR 2011-12/P.No.3/1.28)

1.29 KSRB 0.5-7.4 : Providing white cement mortar with marble dust of mix 1:5
(1 white cement : 5 marble dust) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 6480.00
No. KBS (PWD SR 2011-12/P.No.3/1.29)
1.30 KSRB 0.5-8.1 : Providing fly ash sand mortar of mix 1:1.5:3 (1 cement : 1.5
fly ash : 3 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 3469.00
(PWD SR 2011-12/P.No.3/1.30)

1.31 KSRB 0.5-8.2 : Providing fly ash sand mortar of mix 1:2:4 (1 cement : 2 fly
ash : 4 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 2837.00
(PWD SR 2011-12/P.No.3/1.31)

1.32 KSRB 0.5-8.3 : Providing fly ash sand mortar of mix 1:2.5:5 (1 cement : 2.5
fly ash : 5 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 2485.00
(PWD SR 2011-12/P.No.3/1.32)

1.33 KSRB 0.5-8.4 : Providing fly ash sand mortar of mix 1:3:6.5 (1 cement : 3
fly ash : 6.5 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 2204.00
(PWD SR 2011-12/P.No.3/1.33)
1.34 Mud mortar Cum 80.00
2.0 EARTH WORK FOR BUILDINGS

2.1 KSRB 2-1.1 : Earthwork in surface excavation in ordinary soil for levelling
and lowering the ground manually (other than foundation of buildings,
culverts, road drains and trenches of pipe lines and cables) and removing
the excavated stuff to a distance not exceeding 50m and lift upto 1.5m
excavated surface levelled and neatly dressed, disposed earth to be Cum 112.00
levelled after breaking of clods and neatly dressed as per specifications.
Specification No. KBS 2.1(a) / 2.3.1 (PWD SR 2011-12/P.No.5/2.1)

2.2 KSRB -2-1.2 : Earthwork in surface excavation in hard soil for levelling and
lowering the ground manually (other than foundation of buildings, culverts,
road drains and trenches of pipe lines and cables) and removing the
excavated stuff to a distance not exceeding 50m and lift upto 1.5m
excavated surface levelled and neatly dressed, disposed earth to be Cum 157.00
levelled after breaking of clods and neatly dressed as per specifications.
Specification No. KBS 2.1(b) / 2.3.1 (PWD SR 2011-12/P.No.5/2.2)

2.3 KSRB -2-2.1 : Earthwork excavation for foundation of buildings, culverts,


water supply, sanitary lines and electrical conduits either in pits or in
trenches 1.5m and above in width, in ordinary soil not exceeding 1.5m in
depth including dressing the bottom and sides of pits and trenches,
stacking the excavated soil clear from edges of excavation with lead upto Cum 134.00
50m. after breaking of clods complete as per specifications. Specification
No. KBS 2.1(a) / 2.3.5 (PWD SR 2011-12/P.No.5/2.3)

2.4 KSRB 2-2.2 : Earthwork excavation for foundation of buildings, culverts,


water supply, sanitary lines and electrical conduits either in pits or in
trenches 1.5m and above in width, in hard soil not exceeding 1.5m in
depth including dressing the bottom and sides of pits and trenches,
stacking the excavated soil clear from edges of excavation with lead upto Cum 201.00
50m. after breaking of clods complete as per specifications. Specification
No. KBS 2.1(b) / 2.3.5 (PWD SR 2011-12/P.No.5/2.4)

2.5 KSRB 2-2.3 : Excavation 1.5m and above in width in soft rock by
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead Cum 377.00
upto 50m including cost of explosives, labour and HOM of equipment
complete as per specifications. Specification No. KBS 2.1.C / 2.9.4 / 2.18 /
2.19 (PWD SR 2011-12/P.No.5/2.5)

2.6 KSRB 2-2.4 : Excavation 1.5m and above in width in soft rock without
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead Cum 628.00
upto 50m including cost of labour complete as per specifications.
Specification No. KBS 2.1.C / 2.3.5 (PWD SR 2011-12/P.No.5/2.6)
2.7 KSRB 2-2.5 : Excavation 1.5m and above in width in hard rock by
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead Cum 374.00
upto 50m including cost of explosives, labour and HOM of equipment
complete as per specifications. Specification No. KBS 2.1.d / 2.3.4 / 2.18 /
2.19 (PWD SR 2011-12/P.No.5/2.7)

2.8 KSRB 2.2.6 : Excavation 1.5m and above in width in hard rock by
chiselling and / or wedging, where blasting is prohibited for foundation of
buildings, water supply, sanitary lines and electrical conduits either in pits
or in trenches 1.5 m. in depth, stacking the excavated stuff clear from the Cum 900.00
edge of excavation with lead upto 50m including cost of labour complete
as per specifications. (PWD SR 2011-12/P.No.5/2.8)

2.9 KSRB 2.2-7 : Benching hard rock 5 to 7.5 cm depth. for seating of
foundation including cost of all labour complete as per specifications. Sqm 962.00
Specification No. KBS 2.1.(a) / 2.3.1 (PWD SR 2011-12/P.No.6/2.9)

2.10 KSRB 2.3 : Filling available excavated earth (excluding rock) in sides of
foundations upto plinth in layers not exceeding 20 cms. in depth,
compacting each deposited layer by ramming after watering with lead upto Cum 90.00
50m and lift upto 1.5m including cost of all labour complete as per
specifications. (PWD SR 2011-12/P.No.6/2.10)

2.11 KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not
exceeding 20 cms. in depth, compacting each deposited layer by ramming
after watering with lead upto 50m and lift upto 1.5m including cost of all Cum 54.00
labour complete as per specifications allow 60% of rate considered under
item KSRB 2.3 (PWD SR 2011-12/P.No.6/2.11)

2.12 KSRB 2.5 : Earthwork excavation (in deposited soil) and filling sides of
foundation upto plinth in layers not exceeding 20cms. in depth, compacting
each deposited layer by ramming after watering with lead upto 50m. and
lift upto 1.5m including cost of all labour complete as per specifications. Cum 180.00
Specification No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 (PWD SR 2011-
12/P.No.6/2.12)

2.13 KSRB 2.6 : Providing and filling sand in foundation upto plinth to required
depth for sub soil treatment including watering ramming with lead upto
50m. and lift upto 1.5m complete as per specifications. Specification No. Cum 1207.00
KBS 2.10.2 (PWD SR 2011-12/P.No.6/2.13)

2.14 KSRB 2.7 : Providing and removing shoring and shuttering for protecting
the sides of foundation trenches, wherever required, including cost of all
materials and labour complete as per specifications. Specification No. KBS Sqm 419.00
2.5/2.13 (PWD SR 2011-12/P.No.6/2.14)
2.15 KSRB 2.8 : Filling in foundation with granite/trap broken metal 100mm. and
down size, with approved sand including hand packing, ramming,
watering, including cost of all materials and labour with lead upto 50m. and Cum 1059.00
lift of 1.5m complete as per specification. (PWD SR 2011-12/P.No.6/2.15)

2.16 KSRB 2.9 : Spreading and forming the excavated earth to required level,
slope for an average thickness of 75mm. in all classes of soils all-round
the building and low laying areas complete as per specifications. (PWD SR Sqm 4.18
2011-12/P.No.6/2.16)

2.17 KSRB 2.10 : Providing sand cement bed with 5% cement with a lead of 50
m. for all materials and lift of 1.5m machine mixed, laid in layers of 15cms.
thick and well compacted for foundation, including curing cost of materials Cum 1952.00
labour and HOM complete as per specifications. (PWD SR 2011-
12/P.No.6/2.17)

2.18 KSRB 2.11 : Providing sand cement bed with 10% cement with a lead of
50 m. for all materials and lift of 1.5m machine mixed, laid in layers of
15cms. thick and well compacted for foundation, including curing cost of Cum 2461.00
materials labour and HOM complete as per specifications. (PWD SR 2011-
12/P.No.6/2.18)

2.19 KSRB 2.12 : Providing sand piles with all leads and lift of 1.5m for
stabilising foundation after duly making 5 cms. dia holes to a depth of 1.2
to 1.5m at 0.5 m c to c and filling with sand and tamping wherever required Sqm 149.00
including cost of materials, labour complete as per specifications. (PWD
SR 2011-12/P.No.7/2.19)

2.20 KSRB 2.13 : Providing sand cement piles with all leads and lift of 1.5m
Sqm 91.19 for stabilising foundation bed after making 5 cms. dia holes to a
depth of 1.2 to 1.5m at 0.5 m c to c and filling with sand and 10% cement,
tamping wherever required including cost of materials, labour complete as Sqm 174.00
per specifications. (PWD SR 2011-12/P.No.7/2.20)

2.21 KSRB 2.14-1 : Extra for additional lift of 1.5m. or part thereof for
excavation in loose / soft or hard soil including cost of materials, labour
complete as per specifications. (PWD SR 2011-12/P.No.7/2.21) Cum 9.00

2.22 KSRB 2.14-2 : Extra for additional lift of 1.5m. or part thereof for
excavation in soft or hard rock including cost of materials, labour Cum 16.00
complete as per specifications. (PWD SR 2011-12/P.No.7/2.22)

2.23 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required
and utilising the remaining earth locally for the work in. (Depth upto 3m)
(PWD SR 2009-10/P.No.7/2.23)
2.23.1 Earth work in excavation of foundation of structures as per drawing and
technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 30.00
and utilising the remaining earth locally for the work. Ordinary/Hard soil-
Mechanical Means (Depth upto 3m) (PWD SR 2011-12/P.No.7/2.23.1)

2.23.2 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 40.00
and utilising the remaining earth locally for the work. Ordinary Rock (not
requiring blasting) – Mechanical Means(PWD SR 2011-12/P.No.7/2.23.2)

2.23.3 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 423.00
and utilising the remaining earth locally for the work. Hard Rock (requiring
blasting) – Mechanical Means (PWD SR 2011-12/P.No.7/2.23.3)

2.23.4 Earth work in excavation of foundation of structures as per drawing and


technical specification, including setting setting out, construction of shoring
and bracing, removal of stumps and other deleterious matter, dressing of
sides and bottom, backfilling the excavation earth to the extent required Cum 140.00
and utilising the remaining earth locally for the work. Marshy soil-
Mechanical Means (PWD SR 2011-12/P.No.7/2.23.4)
3.0 ANTITERMITE TREATMENT

3.1 KSRB 3.1 : Supplying chloropyriphos emulisifiable concentrate of 20%, in


sealed containers including delivery as specified sales tax, transport,
Insurance and other levies complete as per specifications. (PWD SR 2011- L 242.00
12/P.No.9/3.1)

3.2 KSRB 3.2 : Providing and injecting chemical emulsion for Pre-
constructional Anti-Termite Treatment, creating continuous chemical
barrier under and around the column pits, walls, trenches, basement
excavation, top surface of the plinth filling, junction of wall and floor, along
the external perimeter of building, expansion joints, over the top surface of
consolidated earth on which apron is to be laid, surrounding of pipes and
conduits, with chloropyriphos emulsifiable concentrates of 20% Sqm 96.00
concentration, including cost of chemical, diluting in water to one percent
concentration, labour, HOM of equipments, complete as per speficiations.
(Plinth area of the building at ground floor only shall be measured)
Specification No. KBS : 3.2.6/3.2.7 (PWD SR 2011-12/P.No.9/3.2)

3.3 KSRB 3.3 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment along external walls where the apron is not
provided using chemical, emusltion at 7.5 Litre/ sqm of the vertical surface
of the substructure to a depth of 300mm. including excavation of channel
along the wall and redoing with chlorophyriphos emulsion concentrate 20%
diluting in water to 1% concentration, including cost of chemicals, diluting m 56.00
in water to one percent cocnentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.3 (PWD SR
2011-12/P.No.9/3.3)

3.4 KSRB 3.4 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment along external walls below concrete or masonry
apron using chemical emulsion at 2.25 litre/m including drilling and
plugging to holes, with chlorophyriphos emulsion concentrate 20% diluting
in water to 10% concentration, including cost of chemicals, diluting in water m 40.00
to one percent concentration, labour, HOM of equipments, complete as per
specifications. Specification No. KBS : 3.3.4 (PWD SR 2011-
12/P.No.9/3.4)

3.5 KSRB 3.5 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment of soil under existing floors using chemical
chemical emulsion at one litre/hole 30mm apart including drilling 12mm.
dia holes and plugging with cement mortar 1:2 proportion to mach with the
existing floors with chlorophyriphos emulsion concentrate 20%, including Sqm 202.00
cost of chemicals diluting in water to one percent concentration, labour,
HOM of equipments, complete as per specifications. (PWD SR 2011-
12/P.No.9/3.5)
3.6 KSRB 3.6 : Providing, injecting chemical emulsion for Pre-constructional
Anti - Termite Treatment of existing masonry using chemical emulsion at
one liter/ hole at 300 mm intervals including drilling of holes at 45 degree
and plugging them with cement mortar 1:2 to the full depth of the hole with
Chloropyriphos emulsifiable concentration 20% including cost of chemical m 64.00
diluting in water to one percent concentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.5 (PWD SR
2011-12/P.No.9/3.6)

3.7 KSRB 3.7 : Providing, injecting chemical emulsion for Pre-constructional


Anti - Termite Treatment at points of contacts of wood work by chemical
emulsion Chloropyriphos (in oil or kerosene based solution) at 0.5 liters
per hole by drilling 6mm. dia holes at downword angle of 45 degree at
150mm. c to c and sealing the same including cost of chemicals, diluting in m 180.00
water to one percent concentration, labour, HOM of equipments, complete
as per specifications. Specification No. KBS : 3.3.7 (PWD SR 2011-
12/P.No.10/3.7)

3.8 Providing general disinfection sevices, spraying of insecticide and


pesticide inside and outside thebuilding (files, bedbugs, liwards,
cockroaches, spiders caterpillars etc. including cost of materials labour
lead lift, hire charges of equipments etc., complete. (PWD SR 2011- Sqm 19.00
12/P.No.10/3.8)
4.0 CEMENT CONCRETE

4.1 KSRB 4-1.1 : Providing and laying in position plain cement concrete of
mix M15 with OPC cement @ 240Kgs, with 40mm and down size graded
granite metal coarse aggregates @ 0.878 cum and fine aggregates @
0.459 cum machine mixed, concrete laid in layers not exceeding 15 cms.
thick , well compacted, in foundation and plinth, including cost of all Cum 3863.00
materials, labour, HOM of machinery, curing complete as per
specifications. specification No. KBS 4.1,4.2 ( PWD SR 2011-12/
P.No.12/4.1)

4.2 KSRB 4-1.2 : Providing and laying in position plain cement concrete of
mix M10 with OPC cement @ 220 kgs, with 40mm and down size graded
granite metal coarse aggregates @ 0.892 cum and fine aggregates
@0.465 cum machine mixed, machine mixed, concrete laid in layers not
exceeding 15 cms, thick, well compacted, in foundation and plinth, Cum 3715.00
including cost of all materials, labour, HOM of machinery, curing complete
as per specification. Specification No. KBS 4.1, 4.2 (PWD SR 2011-
12/P.No. 12/4.2)

4.3 KSRB 4-1.3 : Providing and laying in position plain cement concrete of
mix M7.5 with OPC cement @ 180 kgs, with 40mm and down size graded
granite metal coarse aggregates @ 0.85 cum and fine aggregates @ 5.75
cum machine mixed, concrete laid in layers not exceeding 15 cms, thick,
well compacted, in foundation and plinth, including cost of all materials, Cum 3518.00
labour, HOM of machinery, curing complete as per specification.
Specification No. KBS 4.1, 4.2 (PWD SR 2011-12/P.No. 12/4.3)

4.4 KSRB 4-1.4 : Providing and laying in position plain cement concrete of
mix M5 with OPC cement @ 160kgs, with 40mm and down size graded
granite metal coarse aggregates @ 0.86 cum and fine aggregates @ 0.58
cum machine mixed, machine mixed, concrete laid in kayers not Cum 3396.00
exceeding 15 cms, thick, well compacted, in foundation and plinth,
including cost of all materials, labour, HOM of machinery, curing complete
as per specification. Specification No. KBS 4.1, 4.2 (PWD SR 2011-
12/P.No. 12/4.4)
4.5 KSRB 4-1.5 : Providing and laying in position plain cement concrete of
mix M20 with OPC cement @ 300 kgs, with 20mm and down size graded
granite metal coarse aggregates @ 0.64 cum and fine aggregates @ 0.43
cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-
2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick,
Cum 4404.00
well compacted, in foundation and plinth, including cost of all materials,
labour, HOM of machinery, curing complete as per specification.
Specification No. KBS 4.1, 4.2 (PWD SR 2011-12/P.No. 12/4.5)
4.6 KSRB 4-1.6 : Providing and laying in position plain cement concrete of
mix M15 with cement @ 240kgs, with 20mm and down size graded
granite metal coarse aggregates @ 0.878 cum and fine aggergates @
0.459 cum, machine mixed, concrete laid in layers not exceeding 15 cms.
thick, well compacted, in foundation and plinth, including cost of all Cum 3959.00
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.2 (PWD SR 2011-12/P.No.
12/4.6)

4.7 KSRB 4-1.7 : Providing and laying in position plain cement concrete of
mix M10 with OPC cement @ 220kgs, with 20mm and down size graded
granite metal coarse aggregates @ 0.84cum and fine aggregates @ 0.56
cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick,
well compacted, in foundation and plinth, including cost of all materials, Cum 3897.00
labour, HOM of machinery, curing complete as per specification.
Specification No. KBS 4.1, 4.2 (PWD SR 2011-12/P.No. 13/4.7)

4.8 KSRB 4-1.8 : Extra for laying cement concrete under water including cost
of pumping or dewatering and clearing slush as per specifications. Details
of cost for depth of water 0.3 metres bailing out Specification No.KBS 4.2, Cum 73.00
4.8 (PWD SR 2011-12/P.No. 13/4.8)

4.9 KSRB 4-1.9 : Extra for laying cement concrete under foul conditions.
Cum 99.00
(PWD SR 2011-12/P.No. 13/4.9)

4.10 KSRB 4.2.1 : Providing and laying in position reinforced cement concrete
of design mix M25 with OPC cement @340kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.70cum and fine aggregates
@ 0.47cum, with superplastisiser @ 3lts confirming to IS9103-1999
Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for all works in foundation plinth and ground floor
level for roof slabs, staircase, lintles, retaining walls, return walls, walla
(any thickness) including attached plasters, columns, piers, abutments, Cum 4839.00
pillars, posts, structs, buttresses, string or lacing courses, parpets, coping,
bed blocks, anchor, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.6 (PWD SR 2011-12/P.No.
13/4.10)
4.11 KSRB 4.2.2 : Providing and laying in position reinforced cement concrete
of design mix M20 with OPC cement @320kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.878cum and fine aggregates
@ 0.459cum, with superplastisiser @ 3lts confirming to IS9103-1999
Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for all works in foundation plinth and ground floor
level for roof slabs, staircase, lintles, retaining walls, return walls, walla
(any thickness) including attached plasters, columns, piers, abutments, Cum 4674.00
pillars, posts, structs, buttresses, string or lacing courses, parpets, coping,
bed blocks, anchor, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.6 (PWD SR 2011-12/P.No.
13/4.11)

4.12 KSRB 4.2.3 : Providing and laying in position reinforced cement concrete
of design mix M15 with OPC cement @240kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.878cum and fine aggregates
@ 0.459cum, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for all works in foundation plinth and ground floor
level for roof slabs, staircase, lintles, retaining walls, return walls, walla
(any thickness) including attached plasters, columns, piers, abutments, Cum 4038.00
pillars, posts, structs, buttresses, string or lacing courses, parpets, coping,
bed blocks, anchor, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.6 (PWD SR 2011-12/P.No.
13/4.12)

4.13 KSRB 4.2.4 : Providing and laying in position reinforced cement concrete
of design mix M10 with OPC cement @220kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.792cum and fine aggregates
@ 0.465cum, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for all works in foundation plinth and ground floor
level for roof slabs, staircase, lintles, retaining walls, return walls, walla
(any thickness) including attached plasters, columns, piers, abutments, Cum 3917.00
pillars, posts, structs, buttresses, string or lacing courses, parpets, coping,
bed blocks, anchor, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.6 (PWD SR 2011-12/P.No.
14/4.13)

4.14 KSRB 4.2.5 : Providing and laying in position reinforced cement concrete
of design mix M15 with OPC cement @240kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.878cum and fine aggregates
@ 0.459cum, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for all works in foundation plinth and ground floor
level for roof slabs, staircase, lintles, retaining walls, return walls, walla
(any thickness) including attached plasters, columns, piers, abutments, Cum 3942.00
pillars, posts, structs, buttresses, string or lacing courses, parpets, coping,
bed blocks, anchor, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.6 (PWD SR 2011-12/P.No.
14/4.14)
4.15 KSRB 4.2.6 : Providing and laying in position reinforced cement concrete
of design mix M10 with OPC cement @220kgs, with 40mm and down size
graded granite metal coarse aggregates @ 0.892cum and fine aggregates
@ 0.465cum, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for all works in foundation plinth and ground floor
level for roof slabs, staircase, lintles, retaining walls, return walls, walla
(any thickness) including attached plasters, columns, piers, abutments,
pillars, posts, structs, buttresses, string or lacing courses, parpets, coping, Cum 3794.00
bed blocks, anchor, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing complete as per
specification. Specification No. KBS 4.1, 4.6 (PWD SR 2011-12/P.No.
14/4.15)

4.16 KSRB 4.2.7 : Providing and laying in position reinforced cement concrete
of design mix M25 with OPC cement @340kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.70cum and fine aggregates
@ 0.47cum, with superplastisiser @ 3lts confirming to IS9103-1999
Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for R.C.C. beams, columns of all sizes in foundation Cum 4839.00
plinth and superstructure ground floor level for roof slabs, staircase,
lintles, columns, including cost of all materials, labour, HOM of machinery,
curing complete as per specification. Specification No. KBS 4.1, 4.6 (PWD
SR 2011-12/P.No. 15/4.16)

4.17 KSRB 4.2.8 : Providing and laying in position reinforced cement concrete
of design mix M20 with OPC cement @320kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @ 3lts confirming to IS9103-1999
Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for R.C.C. beams, columns of all sizes in foundation Cum 4674.00
plinth and superstructure ground floor level for roof slabs, staircase,
lintles, columns, including cost of all materials, labour, HOM of machinery,
curing complete as per specification. Specification No. KBS 4.1, 4.6 (PWD
SR 2011-12/P.No. 15/4.17)

4.18 KSRB 4.2.9 : Providing and laying in position reinforced cement concrete
of design mix M15 with OPC cement @240kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.878cum and fine aggregates
@ 0.459cum, machine mixed, concrete laid in layers not exceeding
15cms thick, vibrated for R.C.C. beams, columns of all sizes in foundation
plinth and superstructure ground floor level for roof slabs, staircase, Cum 4038.00
lintles, columns, including cost of all materials, labour, HOM of machinery,
curing complete as per specification. Specification No. KBS 4.1, 4.6 (PWD
SR 2011-12/P.No. 15/4.18)
4.19 KSRB 4.2.10 : Providing and laying in position reinforced cement concrete
of design mix M20 with OPC cement @24kgs, with 12mm and down size
graded granite metal coarse aggregates @ 0.5175cum and fine
aggregates @ 0.345cum, with superplastissiser @ 0.225lts, machine
mixed, well compacted plan chajja of 7.5 cms. average thickness, upto Sqm 342.00
ground floor level, including cost of all materials, labour, HOM of
machinery, curing complete as per specification. Specification No. KBS
4.1, 4.6 (PWD SR 2011-12/P.No. 15/4.19)

4.20 KSRB 4.2.11 : Providing and laying in position reinforced cement concrete
of design mix M20 with OPC cement @27.20kgs, with 12mm and down
size graded granite metal coarse aggregates @ 0.5865cum and fine
aggregates @ 0.391cum, with superplastissiser @ 0.225lts, machine
mixed, well compacted plan chajja of 8.5 cms. average thickness, upto Sqm 386.00
ground floor level, including cost of all materials, labour, HOM of
machinery, curing complete as per specification. Specification No. KBS
4.1, 4.6 (PWD SR 2011-12/P.No. 15/4.20)

4.21 KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chajja
with plastering (labour charges only) as per specification. (PWD SR 2011- m 14.00
12/P.No. 16/4.21)

4.22 KSRB 4-3.1 : Extra if vibrator is used for item No. 4.1 to 4.8 as per as per
specification. Specification No. KBS 4.2.6 (PWD SR 2011-12/P.No. Cum 13.00
16/4.22)

4.23 KSRB 4-3.2 : Deduct where machine mixing is not done Specification No.
KBS 4.2.2.5/4.3.2.2 (PWD SR 2011-12/P.No. 16/4.23) Cum 13.00

4.24 KSRB 4-4.1 : Extra for use of water proofing compound in Cement
concrete of mix M25, at one kg of compound per bag of cement (PWD SR Cum 255.00
2011-12/P.No. 16/4.24)

4.25 KSRB 4-4.2 : Extra for use of water proofing compound in Cement
concrete of mix M20, at one kg of compound per bag of cement (PWD SR Cum 189.00
2011-12/P.No. 16/4.25)

4.26 KSRB 4-4.3 : Extra for use of water proofing compound in Cement
concrete of mix M15, at one kg of compound per bag of cement (PWD SR Cum 151.00
2011-12/P.No. 16/4.26)

4.27 KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick with
6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically
fixing chicken mesh for drop chajja, facia, backing to cup boards including
cost of all materials, labour, providing and removing from work HOM of Sqm 720.00
machineries, curing, complete as per specification. (PWD SR 2011-
12/P.No. 16/4.27)
4.28 KSRB 4-6.1 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for foundations, footings, bases
of columns for mass concrete including cost of all materials, labour
Sqm 163.00
complete as per specification. Specification No. KBS 4.6.2 (PWD SR
2011-12/P.No. 16/4.28)

4.29 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as
suspended floors, roofs, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specification. Sqm 244.00
Specification No. KBS 4-6.2 (PWD SR 2011-12/P.No. 16/4.29)

Rates for centering height more than 3.5 mtrs


-do- for 0.5 mtrs. Rs. 450.00
-do- for 0.6 mtrs. Rs. 600.00
-do- for 0.7 mtrs. Rs. 750.00
-do- for 0.8 mtrs. Rs. 900.00
-do- for 0.9 mtrs. Rs. 1125.00
-do- for 0.10 mtrs. Rs. 1350.00
-do- for 0.11 mtrs. Rs. 1575.00
-do- for 0.12 mtrs. Rs. 1800.00

4.30 KSRB 4-6.3 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as
suspended floors, roofs, landings, balconies and likes, thickness above
200 mm including cost of all materials, labour complete as per Sqm 270.00
specification. Specification No. KBS 4-6.2 (PWD SR 2011-12/P.No.
17/4.30)

4.31 KSRB 4-6.4 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as wall at
any thickness, including attached pilasters, buttresses, plinth and string Sqm 205.00
courses cost of all materials, labour complete as per specification.
Specification No. KBS 4.6.2 (PWD SR 2011-12/P.No. 17/4.31)

4.32 KSRB 4-6.5 : Providing and removing centering, shuttering, strutting,


propping etc., for columns, pillars, piers, abutments, post and struts,
square / rectangular / polygon in plan including cost of all materials,
labour complete as per specification Specification No. KBS 4.6.2 (PWD Sqm 255.00
SR 2011-12/P.No. 17/4.32)

4.33 KSRB 4-6.6 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for columns, pillars, piers, post
and struts, circular or curved in plan including cost of all materials, labour
complete as per specification Specification No. KBS 4.6.2 (PWD SR Sqm 638.00
2011-12/P.No. 17/4.33)
4.34 KSRB 4-6.7 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for sides and soffits of beams
haunchings, cantilever girders, bressumers and lintels not exceeding 1m
in depth including cost of all materials, labour complete as per Sqm 178.00
specification Specification No. KBS 4.6.2 (PWD SR 2011-12/P.No.
17/4.34)

4.35 KSRB 4-6.8 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for sides and soffits of beams
beams haunchings, cantilever, girders, bressumers and lintels exceeding
1m in depth including cost of all materials, labour complete as per Sqm 240.00
specification Specification No. KBS 4.6.2 (PWD SR 2011-12/P.No.
17/4.35)

4.36 KSRB 4-6.9 : Providing and removing centering, shuttering, strutting,


propping etc., for edges of slabs and breaks in floor, cills, plinth including
cost of all materials, labour complete as per specification. Specification Sqm 514.00
No. KBS 4.6.2 (PWD SR 2011-12/P.No. 17/4.36)

4.37 KSRB 4-6.10 : Providing and removing centering, shuttering, strutting,


propping etc., for chajjas, corbles etc., including edges including cost of
all materials, labour complete as per specification. Specification No. KBS Sqm 191.00
4.6.2 (PWD SR 2011-12/P.No. 17/4.37)

4.38 KSRB 4-6.11 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for Stairs (excluding landing)
except spiral staircase including cost of all materials, labour complete as Sqm 354.00
per specification. Specification No. KBS 4.6.2 (PWD SR 2011-12/P.No.
17/4.38)

4.39 KSRB 4-6.12 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for cornices and mouldings
including cost of all materials, labour complete as per specification. Sqm 379.00
Specification No. KBS 4.6.2 (PWD SR 2011-12/P.No. 18/4.39)

4.40 KSRB 4-6.13 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for vertical fins and vertical fibs
and vertical sun breakers including cost of all materials, labour complete Sqm 319.00
as per specification. Specification No. KBS 4.6.2 (PWD SR 2011-12/P.No.
18/4.40)

4.41 KSRB 4-6.14 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for sloping or battering surface
including folded plates where inclination to horizontal plane does not
exceed 30 degree requiring shuttering only on the under side including Sqm 297.00
cost of all materials, labour complete as per specifications. Specification
No. KBS 4.6.2 (PWD SR 2011-12/P.No.18/4.41)
4.42 KSRB 4-6.15 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for where inclination to horizontal
plane exceeds 30 degree (where shuttering may be provided both on
under side and upper side if required) including cost of all materials, Sqm 463.00
labour complete as per specifications. Specification No. KBS 4.6.2 (PWD
SR 2011-12/P.No. 18/4.42)

4.43 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using
10-15 cms. dia best quality casurina poles of 4m over all length (3m +
05m in to the ground), the distance between two rows being 1.25m and
spacing of posts being 2m in both rows with 2 horizontal posts with 0.5
mm overlap on either side and braces at 2m c to c including longitudinal m 202.00
and transveres middle braces to step up and providing platform with
casurina poles, forms tied up using coir rope complete as per specification
(PWD SR 2011-12/P.No. 18/4.43)

4.44 KSRB 4-8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length
(3m+0.5m projection + 0.5m in to the ground) the distance between two
rows being 1.25m and spacing of post being 2m in both rows with 2
horizontal posts with 0.5 mm overlap on either side and braces at 2m c to
including longitudinal and transveres middle braces to step up and
providing platform with casurina poles, forms tied up using coir rope
complete as per specifications. Specification No. KBS (PWD SR 2011-
12/P.No. 18/4.44)

4.44.1 KSRB 4-8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length
(3m+0.5m projection + 0.5m in to the ground) the distance between two
rows being 1.25m and spacing of post being 2m in both rows with 2
horizontal posts with 0.5 mm overlap on either side and braces at 2m c to
including longitudinal and transveres middle braces to step up and Cum 168.00
providing platform with casurina poles, forms tied up using coir rope
complete as per specifications for non modular brick work (Non modular
standard bricks : 4x0.23x3 = 2.76 cum) (PWD SR 2011-12/P.No.
18/4.44.1)

4.44.2 KSRB 4-8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length
(3m+0.5m projection + 0.5m in to the ground) the distance between two
rows being 1.25m and spacing of post being 2m in both rows with 2
horizontal posts with 0.5 mm overlap on either side and braces at 2m c to
including longitudinal and transveres middle braces to step up and Cum 194.00
providing platform with casurina poles, forms tied up using coir rope
complete as per specifications for modular brick work (Modular bricks :
4x0.2x3 = 2.4 cum) (PWD SR 2011-12/P.No. 18/4.44.2)
4.44.3 KSRB 4.8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length
(3m+0.5m projection + 0.5m in to the ground) the distance between two
rows being 1.25m and spacing of post being 2m in both rows with 2
horizontal posts with 0.5 mm overlap on either side and braces at 2m c to
including longitudinal and transveres middle braces to step up and Sqm 39.00
providing platform with casurina poles, forms tied up using coir rope
complete as per specifications for non modular brick work (PWD SR
2011-12/P.No. 18/4.44.3)

4.44.4 KSRB 4.8 : Providing 2 legged scaffolding for brick masonry work using
10-15 cms. dia best quality Casurina poles of 4m over all length
(3m+0.5m projection + 0.5m in to the ground) the distance between two
rows being 1.25m and spacing of post being 2m in both rows with 2
horizontal posts with 0.5 mm overlap on either side and braces at 2m c to
including longitudinal and transveres middle braces to step up and Sqm 39.00
providing platform with casurina poles, forms tied up using coir rope
complete as per specifications for modular brick work (PWD SR 2011-
12/P.No. 18/4.44.4)

4.45 KSRB 4.9.1 : Providing mild steel reinforcement for RCC work including
straightening, curring, bending, hooking, placing in position, lapping and /
or welding wherever required, tying with binding wire and anchoring to the
adjoining members wherever necessary complete as per design (laps,
hooks and wastage shall not be measured and paid) cost of materials,
q 5910.00
labour, HOM of machinery complete as per specifications. Specification
No. KBS 4.6.3 (PWD SR 2011-12/P.No. 19/4.45)

4.46 KSRB 4.9.2 : Providing TMT steel reinforcement for RCC work including
straightening, cutting, bending, hooking, placing in position, lapping and /
or welding wherever required, tying with binding wire and anchoring to the
adjoining members wherever necessary complete as per design (laps,
hooks and wastage shall not be measured and paid) cost of materials, q 5910.00
labour, HOM of machinery complete as per specifications. Specification
No. KBS 4.6.3 (PWD SR 2011-12/P.No. 19/4.46)

4.47 Lift charges for steel of all diameters for additional floors over ground floor
per q floor height of 3.5 m. or part thereof cost of labour, complete as per
specification (P.W.D. SR 2011-12/P.No. 19/4.47) q 34.00

4.48 Providing and laying cement concrete using 20 mm and down size granite
jelly of ready mixed concrete (RMC) for R.C.C. works laid in 15 cms thick
layers and well compacted vibrating, curing, finishing with necessary
cement mortar, with all lead and lifts etc., complete (exclusive of cost of
steel and fabrication charges.) (P.W.D. SR 2011-12/P.No. 19/4.48)
4.48.1 Ready mixed Cement concrete M-20 for raft foundation, column footing,
main and secondary beams. (P.W.D. SR 2011-12/P.No. 19/4.48.1) Cum 4401.00

4.49 Providing and laying cement concrete using 20 mm and down size granite
jelly of ready mixed concrete for R.C.C. works laid in 15 cms thick layers
and well compacted including vibrating, curing including smooth finish in
CM 1:3, with all lead and lift etc., complete (exclusive of cost of steel and
fabrication charges.) (P.W.D. SR 2011-12/P.No. 19/4.49)

4.49.1 -do- Ready mixed Cement concrete for Beams, columns, Staircase and
Roof with M-20 ( cement-320Kg/cum) (P.W.D. SR 2011-12/P.No. Cum 4401.00
19/4.49.1)

4.49.2 -do- Ready mixed Cement concrete for Beams, columns, Staircase and
Roof with M-25 ( cement-340Kg/cum) (P.W.D. SR 2011-12/P.No. Cum 4886.00
19/4.49.2)

4.49.3 -do- Ready mixed Cement concrete for Beams, columns, Staircase and
Roof with M-30 ( cement-360Kg/cum) (P.W.D. SR 2011-12/P.No. Cum 5120.00
19/4.49.2)

4.49.4 -do- Ready mixed Cement concrete for Beams, columns, Staircase and
Roof with M-35 ( cement-390Kg/cum) (P.W.D. SR 2011-12/P.No. Cum 5550.00
19/4.49.2)

4.49.5 -do- Ready mixed Cement concrete for Beams, columns, Staircase and
Roof with M-40 ( cement-420 Kg/cum) (P.W.D. SR 2011-12/P.No. Cum 5980.00
19/4.49.2)

4.50 KSRB 4.7 Scaffolding for stone masionry as in sl no. 4.43 converted to
Cum. (P.W.D. SR 2011-12/P.No. 19/4.50) Cum 149.00

4.51 KSRB 4.7 Scaffolding for stone masionry work as in sr no. 4.43 converted
to Sqm. (P.W.D. SR 2011-12/P.No. 20/4.51) Sqm 68.00

4.52 Providing and mixing synthetic fibers 100% vigin triangular monofillament
polyester fibers, 12mm in cut length for use as secondary fiber
reinforcement in concrete works. application per cubic meter shall be 125
grams per bag of cement or 0.25% by weight of cement. (P.W.D. SR
2011-12/P.No. 20/4.52)

4.52.1 Providing and mixing synthetic fibers 100% vigin triangular monofillament
polyester fibers, 12mm in cut length for use as secondary fiber
reinforcement in concrete works. application per cubic meter shall be 125
Cum 270.00
grams per bag of cement or 0.25% by weight of cement for M15 concrete.
(P.W.D. SR 2011-12/P.No. 20/4.52.1)
4.52.2 Providing and mixing synthetic fibers 100% vigin triangular monofillament
polyester fibers, 12mm in cut length for use as secondary fiber
reinforcement in concrete works. application per cubic meter shall be 125
grams per bag of cement or 0.25% by weight of cement for M 20 Cum 348.00
concrete. (P.W.D. SR 2011-12/P.No. 20/4.52.2)

4.53 Providing and mixing fibermesh MD (Multi Dimensional) Graded


( fibermesh inforce e3) fibrilated ( interconnected bundles of fibres that
open up during the mix process) 100% virgin Polypropylene fibres
contains no reprocessed olefin materials and are specially manufactured
with 25 individual unique fibre design to an optimum gradiation for use as
complete secondary reinforcement. Application per cubic meter shallrqual
a minimum of 0.1% by volume (0.9kg per cubic meter) in the concrete. Kgs 693.00
Fibermesh MD Graded polypropylene fibrilated fiber should confirm to
ASTMC 1116 type III 4.1.3 ASTMC 1116 performance level 1% ASTMC
1339 ( Minimum average residual strength of 0.35 Mpa) (P.W.D. SR
2011-12/P.No. 20/ 4.53)

4.54 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olfrin materials and are specifically manufactured for use as
concrete secondary reinforcement. Application per cubic meter shall be @
0.9kg to 1.8 kg per cum of concrete. Fibermesh stealth e3 shall confirm to Kgs 395.00
ASTM C-1116 type 111. 4.106. (P.W.D. SR 2011-12/P.No. 20/4.54)

4.55 Providing and casting reinforced cement concrete racks with design mix
M20, granite or trap jelly 12mm and down size 5 cms thick and below with
reinforcement of 6mm dia MS bars at 15cms. Centre to centre for main
reinforcement and at 30cms centre to centre for distribution including
supports wherever necessary with burnt brick in Cm 1:8 and plastered Sqm 517.00
with CM 1:4 or composite mortar 1:6 including centring, from work, curing
etc., complete ( inclusive of cost of steel and fabrication charges) (P.W.D.
SR 2011-12/P.No.20/4.55)

4.56 Providing RCC loft (atta) 7.5cms thick with cement concrete design mix
M20 using clean granite or trap jelly of 20mm and down size with
necessary reinforcements at 20cms centre to centre as per design
including form work, centering, curing, finishing the exposed faces with Sqm 383.00
cement mortar (1:3) etc., complete (exclusive of cost of steel and
fabrication charges.) (P.W.D.SR 2011-12/P.No.20/4.56)

4.57 Providing and fixing RCC slabs 5cms thick for wall shelves with 12mm
and down size jelly cement concrete design mix M20 including CM 1:3
plaster finishing, curing etc., complete (excluding the cost of steel and Sqm 414.00
fabrication charges.) P.W.D SR 2011-12/P.No.20/4.57
4.58 Providing RCC design mix M20 using granite metal 20mm and down size
for 7.5cms thick solid parapet or perforated as per design, specification
and directions. (exclusive of cost of steel and fabrication charges )
including necessary Centering, form work and finishing smooth with CM
(1:3) etc., complete. (P.W.D SR 2011-12/ P.No. 20/4.58)

4.58.1 Providing RCC design mix M20 using granite metal 20mm and down size
for 7.5cms thick solid parapet or perforated as per design, specification
and directions. (exclusive of cost of steel and fabrication charges )
including necessary Centering, form work and finishing smooth with CM Sqm 332.00
(1:3) etc., complete. (P.W.D SR 2011-12/ P.No. 20/4.58)

4.58.2 Providing RCC design mix M20 using granite metal 20mm and down size
for 10 cms thick solid parapet or perforated as per design, specification
and directions. (exclusive of cost of steel and fabrication charges )
including necessary Centering, form work and finishing smooth with CM Sqm 475.00
(1:3) etc., complete. 10cms thick (P.W.D SR 2011-12/ P.No. 20/4.58.2)
5.0 STONE WORK

5.1 KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble stone
masonry in foundation with mud mortar (uncoursed), bond stones at two
m. apart in each course including cost of materials, labour, curing Cum 1121.00
complete as per specifications. KBS 5.1.12 (PWD SR 2011-
12/P.No.25/5.1)

5.2 KSRB 5-1.2 : Providing and constructing granite / trap / basalt rubble stone
masonry in foundation with cement mortar 1:8 (uncoursed), bond
stones at two m. apart in each course including cost of materials, labour,
curing complete as per specifications. KBS 5.1.12 (PWD SR 2011- Cum 1991.00
12/P.No.25/5.2)

5.3 KSRB 5-1.3 : Providing and constructing granite / trap / basalt rubble stone
masonry in foundation with cement mortar 1:6 (uncoursed), bond stones at
two m. apart in each course including cost of materials, labour, curing
complete as per specifications. KBS 5.1.12 (PWD SR 2011- Cum 2134.00
12/P.No.25/5.3)

5.4 KSRB 5-2.1 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with mud mortar, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart in each
Cum 1709.00
course including cost of materials, labour, curing complete as per
specifications. KBS 5.1.12 (PWD SR 2011-12/P.No.25/5.4)

5.5 KSRB 5-2.2 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with cement mortar 1:8, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart i each Cum 2447.00
course indluing cost of materials, labour, curing complete as per
specifications. KBS 5.1.13 (PWD SR 2011-12/P.No.25/5.5)

5.6 KSRB 5-2.3 : Providing and constructing granite / trap / basalt size stone
masonry in foundation cement mortar 1:6, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart i each
course indluing cost of materials, labour, curing complete as per Cum 2568.00
specifications. KBS 5.1.13 (PWD SR 2011-12/P.No.25/5.6)

5.7 KSRB 5-3.1 : Providing and constructing granite / trap / basalt size stone
masonry in basement with mud mortar, edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each
course including cost of materials, labour, curing complete as per Cum 2146.00
specifications. KBS 5.1.13 (PWD SR 2011-12/P.No.25/5.7)
5.8 KSRB 5-3.2 : Providing and constructing granite / trap / basalt size stone
masonry in basement with cement mortar 1:8, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, curing complete as per Cum 2885.00
specifications. KBS 5.1.13 (PWD SR 2011-12/P.No.25/5.8)

5.9 KSRB 5-3.3 : Providing and constructing granite / trap / basalt size stone
masonry in basement with cement mortar 1:6, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, curing complete as per Cum 3006.00
specifications. KBS 5.1.13 (PWD SR 2011-12/P.No.26/5.9)

5.10 KSRB 5-4.1 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with mud mortar, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 2311.00
complete as per specifications. KBS 5.1.13 (PWD SR 2011-
12/P.No.26/5.10)

5.11 KSRB 5-4.2 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:8, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 3051.00
complete as per specifications. KBS 5.1.13 (PWD SR 2011-
12/P.No.26/5.11)

5.12 KSRB 5-4.3 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:6, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 3172.00
complete as per specifications. KBS 5.1.13 (PWD SR 2011-
12/P.No.26/5.12)

5.13 KSRB 5-4.4 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:4, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart
in each course including cost of materials, labour, scaffolding, curing Cum 3434.00
complete as per specifications. KBS 5.1.13 (PWD SR 2011-
12/P.No.26/5.13)

5.14 KSRB 5-5 :Extra lift charges for size stone masonry above ground floor for
every additinal floor. KBS 5.1.13 (PWD SR 2011-12/P.No.26/5.14) Cum 138.00

5.15 KSRB 5-6 :Extra for constructing stone masonry square or rectngular
pillars complete as per specifications. KBS 5.1.13 (PWD SR 2011- Cum 214.00
12/P.No.26/5.15)
5.16 KSRB 5-7 :Extra for constructing masonry in circular pillars including cost
of extra mateirals and labour compete as per specifications. KBS 5.1.13 Cum 487.00
(PWD SR 2011-12/P.No.26/5.16)

5.17 KSRB 5-8.1 : Providing one line dressing to granite stone slab / granite
stone masonry as per specifications. KBS 5.1.13(PWD SR 2011- Sqm 388.00
12/P.No.26/5.17)

5.18 KSRB 5-8.2 : Providing two line dressing to granite stone slab / granite
stone masonry as per specifications. KBS 5.1.13(PWD SR 2011- Sqm 647.00
12/P.No.26/5.18)

5.19 KSRB 5-8.3 : Providing three line dressing to granite stone slab / granite
stone masonry as per specifications. KBS 5.1.13(PWD SR 2011- Sqm 906.00
12/P.No.27/5.19)

5.20 KSRB 5-8.4 : Providing pulmane finish only on three line dressed surface
as per specifications. KBS 5.1.13(PWD SR 2011-12/P.No.27/5.20) Sqm 256.00

5.21 KSRB 5-8.5 : Providing quoin dressing to stone masonry and stone slabs,
two line 5 cms wide on each face as per specifications. (measurement
including mortar joints) KBS 5.1.13(PWD SR 2011-12/P.No.27/5.21) m 65.00

5.22 KSRB 5-9 : Providing chamfering edges to stone slab 2.5 cms wide as per
specifications. (only chamfered length shall be recorded) KBS 5.1.13) m 25.00
(PWD SR 2011-12/P.No.27/5.22)

5.23 KSRB 5-10 : Providing hammer dressing to size stones as per


specifications KBS 5.1.13.3 (PWD SR 2011-12/P.No. 27/5.23) No 5.00

5.24 KSRB 5-11 : Providing and constructing load bearing wall with cement
concrete cavities blocks (hollow blocks) of proportion 1:5:3 blocks of
size 40 x 20 x 20 cms. (1 x b x h) strength not less than 50kg. per sqm
with cement mortar 1:4 conforming to I.S. 2185 of 1967 having not less
than 40mm. shell thickness with two or more large cavities and having Sqm 578.00
solid material between including cost of materials, labour charges,
scaffolding, curing complete as per specification. KBS 5.4 (PWD SR 2011-
12/P.No. 27/5.24)

5.25 KSRB 5-12 : Providing and constructing load bearing wall with cement
concrete cavities blocks (hollow blocks) of proportion 1:5:3 blocks of size
40 x 20 x 20 cms. (1 x b x h) strength not less than 35kg. per sqm with
cement mortar 1:4 conforming to I.S. 2185 of 1965 having not less than
40mm. shell thickness with two or more large cavities and having solid Sqm 571.00
material between including cost of materials, labour charges, scaffolding,
curing complete as per specification. (PWD SR 2011-12/P.No. 27/5.25)
5.26 KSRB 5-13 : Providing and constructing non-load bearing wall with cement
concrete cavities blocks (hollow blocks) of proportion 1:5:3 blocks of size
40 x 10 x 20 cms. (1 x b x h) strength not less than 35kg. per sqm with
cement mortar 1:4 conforming to I.S. 2185 of 1967 having not less than
40mm. shell thickness 50% of total volume of block having two large Sqm 475.00
cavities with 20mm. wall thickness in between including cost of mateirals,
labour charges, scaffolding, curing complete as per specification. (PWD
SR 2011-12/P.No. 27/5.26)

5.27 KSRB 5-14: Providing and constructing precast concrete solid blocks with
compressive strength not less than 35 kg/sqm with cement mortar 1:4
masonry )quoin, Jamb, closer blocks) with solid concrete blocks of size 40
x 20 x 20 cms. conforming to I.S. 2185 of 1965 in superstructure including Sqm 652.00
cost of materials, labour charges, scaffolding, curing complete as per
specification. (PWD SR 2011-12/P.No. 27/5.27)

5.28 KSRB 5-15 : Providing and constructing non-loab bearing wall with cement
concrete solid blocks with compressive strenght not less than 35 kg/sqm
with cement mortar 1:4 (Jamb, closer blocks) with blocks of size 40 x 10 x
20 cms. )lxbxh) conforming to I.S. 2185 of 1965 in superstructure including Sqm 477.00
cost of materials, labour charges, scaffolding, curing complete as per
specification. (PWD SR 2011-12/P.No. 28/5.28)

5.29 Providing and fixing Pre cast solid concrete kerb stones made out of CC
1:2:4 of size 450 x 200 x 400mm and finished with CM 1:3 plastering and
finishing cutting etc., complete.(PWD SR 2011-12/P.No. 28/5.29)

5.29.1 Providing and fixing Pre cast solid concrete kerb stones made out of CC
1:2:4 of size 450 x 200 x 400mm and finished with CM 1:3 plastering and
finishing cutting etc., complete.(PWD SR 2011-12/P.No. 28/5.29.1) No 269.00

5.29.2 Providing and fixing Pre cast solid concrete kerb stones made out of CC
1:2:4 of size 450 x 150 x 500mm and finished with CM 1:3 plastering and
finishing cutting etc., complete.(PWD SR 2011-12/P.No. 28/5.29.2) No 260.00

5.30 Providing and fixing pre cast solid cement concrete kerb stones made out
of C.C. 1:2:4 with top and bottom width 114 and 165mm respectively,
400mm high and 450mm in length finished with CM 1:3 plastering and
finishing cutting, including formwork, curing,including cost of all materials,
labour, hire charges of machinery, loading, unloadng lead and lift, No. 230.00
transportation etc., complete. (PWD SR 2011-12/P.No. 28/5.30)

5.31 Providing granite slabs of selected quality roughly dressed and fixed in
cement mortar (1:6) including fixing curing etc., complete.(PWD SR 2011-
12/P.No. 28/5.31)
5.31.1 Providing granite slabs of selected quality 7.5cms thick, roughly dressed
and fixed in cement mortar (1:6) including fixing curing etc., complete. Sqm 303.00
(PWD SR 2011-12/P.No. 28/5.31.1)

5.31.2 Providing granite slabs of selected quality 10cms thick, roughly dressed
and fixed in cement mortar (1:6) including fixing curing etc., complete. Sqm 460.00
(PWD SR 2011-12/P.No. 28/5.31.2)

5.32 Removing B.S. slab of drain and stacking (PWD SR 2011-12/P.No.


Sqm 44.00
28/5.32)

5.33 Refixing stone slabs of drains and pointing in C.M (1:3) (PWD SR 2011-
12/P.No. 28/5.33) Sqm 55.00
6.0 BRICK WORK (2009-10)
6.1 KSRB 6-1.1 : Providing and constructing burnt brick masonry with
approved quality of non modular bricks of standard size of class
designation 35 wtih mud mortar for basement and superstructure including
cost of materials, labour charges, scaffolding, curing complete as per Cum 3031.00
specifications. Specification No. KBS 6.2 (PWD SR 2011-12/P.No. 30/6.1)

6.2 KSRB 6-1.2 : Providing and constructing burnt brick masonry for basement
and superstructure with approved quality of non- modular bricks of
standard size of class designation 35 wtih cement mortar 1:8 including
cost of materials, labour charges, scaffolding, curing complete as per Cum 3707.00
specifications. Specification No. KBS 6.2 (PWD SR 2011-12/P.No. 30/6.2)

6.3 KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement
and superstructure with approved quality of non- modular bricks of
standard size of class designation 35 wtih cement mortar 1:6 including
cost of materials, labour charges, scaffolding, curing complete as per Cum 3811.00
specifications. Specification No. KBS 6.2 (PWD SR 2011-12/P.No. 30/6.3)

6.4 KSRB 6-2.1 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 (table moulded) wtih mud mortar for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 3704.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 30/6.4)

6.5 KSRB 6-2.2 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 (table moulded) wtih cement mortar 1:8 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 4403.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 30/6.5)

6.6 KSRB 6-2.3 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 (table moulded) wtih cement mortar 1:6 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 4523.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 30/6.6)

6.7 KSRB 6-2.4 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 50 wtih cement mortar 1:4 for basement and superstructure
including cost of materials, labour charges, scaffolding, curing complete as Cum 4747.00
per specifications. Specification No. KBS 6.2 (PWD SR 2011-12/P.No.
30/6.7)
6.8 KSRB 6-3.1 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 with cement mortar 1:8 for basement and
superstructure (Machine moulded Wirecut bricks) with cost of materials, Cum 8149.00
labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2 (PWD SR 2011-12/P.No. 30/6.8)

6.9 KSRB 6-3.2 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 wtih cement mortar 1:6 for basement and superstructure
(Machine moulded Wirecut bricks) with cost of materials, labour charges, Cum 8253.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2011-12/P.No. 31/6.9)

6.10 KSRB 6-3.3 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 wtih cement mortar 1:4 for basement and superstructure
(Machine moulded Wirecut bricks) with cost of materials, labour charges, Cum 8477.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2011-12/P.No. 31/6.10)

6.11 KSRB 6-3.4 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 75 wtih cement mortar 1:3 for basement and superstructure
(Machine moulded Wirecut bricks) with cost of materials, labour charges, Cum 8701.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2011-12/P.No. 31/6.11)

6.12 KSRB 6-4.1 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 35 wtih mud mortar for basement and superstructure Cum 3324.00
with cost of materials, labour charges, scaffolding, curing complete as per
specifications. (PWD SR 2011-12/P.No. 31/6.12)

6.13 KSRB 6-4.2 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 35 wtih cement mortar 1:8 for basement and
superstructure with cost of materials, labour charges, scaffolding, curing Cum 3911.00
complete as per specifications. Specification No. KBS 6.2 (PWD SR 2011-
12/P.No. 31/6.13)

6.14 KSRB 6-4.3 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 354 with cement mortar 1:6 for basement and
superstructure with cost of materials, labour charges, scaffolding, curing Cum 4002.00
complete as per specifications. Specification No. KBS 6.2 (PWD SR 2011-
12/P.No. 31/6.14)
6.15 KSRB 6-5.1: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
50(table moulded) with mud mortar for basement and superstructure
including cost of materials, labour charges, scaffolding, curing complete as Cum 4234.00
per specifications. Specification No. KBS 6.2 (PWD SR 2011-12/P.No.
31/6.15)

6.16 KSRB 6-5.2: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
50(table moulded) with cement mortar 1:8 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 4865.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No.32/6.16)

6.17 KSRB 6-5.3: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
50(table moulded) with cement mortar 1:6 for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 4956.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 32/6.17)

6.18 KSRB 6-5.4: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 50
(table moulded) with cement mortar 1:4 for basement and superstructure
including cost of materials, labour charges, scaffolding, curing complete as Cum 5152.00
per specifications. (PWD SR 2011-12/P.No. 32/6.18)

6.19 KSRB 6-6.1: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
75 (Machine moulded Wirecut bricks) with cement mortar 1:8 for
basement and superstructure including cost of materials, labour Cum 7729.00
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2011-12/P.No. 32/6.19)

6.20 KSRB 6-6.2: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 75
(Machine moulded Wirecut bricks) with cement mortar 1:6 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum 7820.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 32/6.20)

6.21 KSRB 6-6.3: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 75
(Machine moulded Wirecut bricks) with cement mortar 1:4 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum 8017.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 32/6.21)
6.22 KSRB 6-6.4: Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation 75
(Machine moulded Wirecut bricks) with cement mortar 1:3 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum 8213.00
curing complete as per specifications. Specification No. KBS 6.2 (PWD SR
2011-12/P.No. 32/6.22)

6.23 KSRB 6-7.1 : Construction of partition wall 11.2 cms thick with non-
modular ground moulded burnt bricks of class designation 35 with cement
mortar 1:4 including Providing and fixing plaster mesh manufactured out of
hot dipped galvanised iron of nominal thickness 0.35mm 100mm. wide as
per I.S. 2212/1991 at 7.5 m c to c including cost of materials, labour Sqm 529.00
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2011-12/P.No.32/6.23)

6.24 KSRB 6-7.2 : Construction of partition wall 11.2 cms thick with non-
modular table moulded burnt bricks of class designation 50 with cement
mortar 1:4 including Providing and fixing plaster mesh manufactured out of
hot dipped galvanised iron of nominal thickness 0.35mm 100mm. wide as
Sqm 642.00
per I.S. 2212/1991 at 7.5 m c to c including cost of materials, labour
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2011-12/P.No.34/6.24)

6.25 KSRB 6-7.3 : Construction of partition wall 11.2 cms thick with non-
modular ground moulded burnt bricks of class designation 35 with cement
mortar 1:4 including cost of materials, labour charges, scaffolding, curing Sqm 507.00
complete as per specifications. KBS 6.2 (PWD SR 2011-12/P.No.33/6.25)

6.26 KSRB 6-7.4 : Construction of partition wall 11.2 cms thick with non-
modular table moulded burnt bricks of class designation 50 with cement
mortar 1:4 including cost of materials, labour charges, scaffolding, curing Sqm 605.00
complete as per specifications. Specification No. KBS 6.2 (PWD SR 2011-
12/P.No.33/6.26)

6.27 KSRB 6-8.1 : Construction of partition wall 10 cms thick with ground
moulded modular burnt bricks of class designation 35 with cement
mortar 1:4 including providing and fixing plaster mesh manufactured out
of hot dipped gelvanised iron of nominal thickness 0.35mm. 100 mm. wide
as per I.S. 2212/1991 at 7.5 m c to c including cost of materials, labour Sqm 498.00
charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWD SR 2011-12/P.No.33/6.27)

6.28 KSRB 6-8.2 : Construction of partition wall 10 cms thick with table moulded
modular burnt bricks of class designation 50 with cement mortar 1:4
including providing and fixing plaster mesh manufactured out of hot dipped
gelvanised iron of nominal thickness 0.35mm. 100 mm. wide as per I.S.
2212/1991 at 7.5 m c to c including cost of materials, labour charges, Sqm 602.00
scaffolding, curing complete as per specifications. Specification No. KBS
6.2 (PWD SR 2011-12/P.No.33/6.28)
6.29 KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground
moulded modular burnt bricks of class designation 35 with cement mortar
1:4 including cost of materials, labour charges, scaffolding, curing Sqm 448.00
complete as per specifications. Specification No.KBS 6.2 (PWD SR 2011-
12/P.No.33/6.29)

6.30 KSRB 6-8.4 :Construction of partition wall 10 cms thick with table moulded
modular burnt bricks of class designation 50 with cement mortar 1:4
including cost of materials, labour charges, scaffolding, curing complete as Sqm 566.00
per specifications. Specification No. KBS 6.2 (PWD SR 2011-
12/P.No.33/6.30)
STEEL AND ALLUMINIUM WORK
7.1 KSRB 7.1 : Providing and fixing in position collapsible steel shutters with
single or double leaf with vertical channel 20mm x 10mm x 2mm braced
with flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron
sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt
and nuts, locking arrangements, stoppers, handles on both sides with
7.5cms openings at 10 cms. c to c applying a priming coat of red lead Sqm 3514.00
paint. Cost of materials, labour, HOM of machinery complete as per
specifications. size of gate 2.4m x 1.4m. Specification No. KBS 7.7/7.12
(PWD SR 2011-12/P.No.36/7.1)

7.2 KSRB 7.2 : Providing and fixing 1mm thick M.S. Sheet sliding shutters with
frame and diagonal braces of 40x40x6mm angle iron 3.15mm thick M.S
Gusset plates at junctions and corners, 25mm dia pulley, 40x40x6 mm
angles and T iron guide rail top and bottom respectively with handles,
stoppers and locking arrangements etc., including applying a priming coat Sqm 2753.00
of red lead paint cost of materials, labour HOM of machinery complete as
per specifications. 1 Double leaf door of size 2.4m x 2.4m. Specification
No. KBS 7.8/7.12 (PWD SR 2011-12/P.No.36/7.2)

7.3 KSRB 7.3 : Providing and fixing 1mm thick M.S. Sheet garage door with
frame and diagonal braces of size 40x40x6 mm angle iron, 3.15mm thick
M.S. Gussel plates at the junctions and corners, with handles, stoppers
and locking arrangements etc., including applying a priming coat of red
lead paint cost of materials, labour HOM of machinery complete as per Sqm 2203.00
specifications. Double leaf door of size 2.4m x 2.4m. Specification No.
KBS 7.9/7.12 (PWD SR 2011-12/P.No.36/7.3)

7.4 KSRB 7.4 : Providing and fixing 1mm thick M.S. Sheet garage door with
frame and diagonal braces of size 40x40x6 mm angle iron, using M.S. flats
30x6 mm for diagonal braces and central cross pieces 3.15mm thick MS
Gusset plates at the junctions and corners, with handles, stoppers and
locking arrangements etc., including applying a priming coat of red lead
Sqm 1816.00
paint cost of materials, labour, HOM of machinery complete as per
specifications. 1bouble leaf door of size 2.4m x 2.4m. Specification No.
KBS 7.9/7.12 (PWD SR 2011-12/P.No.36/7.4)
7.5 KSRB 7.5 : Providing and fixing pull and push type rolling shutters of
approved make out of 18 guage, 75mm wide cold rolled steel laths of
convex corrugation, with side guides and bottom rail, with interlocking
arrangments for steel laths by means of alternate clips, suspension shaft
with High tension coil type springs two numbers, mounted on specially
designed pipe shaft, with bracket plates, guide channels, ball bearing
arrangements, for inside & outside locking with push & pull operations Sqm 2695.00
complete including pulling hooks, 4Nos. handles with all fittings and
accessories, painted with a coat of red lead paint (without top cover) cost
of materials, labour, HOM of machinery complete as per specifications.
Shutter size 3m x 2.8m. Specification No. KBS 7.10/7.12 (PWD SR 2011-
12/P.No.36/7.5)

7.6 KSRB 7.6 : Providing and fixing top convers made out of 20 guage M.S.
Sheet over pull and push rolling shutters bent to shape including cost of
red lead primer coat of painting, materials, labour, HOM of machinery m 442.00
complete as per specifications. Specification No. KBS 7.10.6/7.12 (PWD
SR 2011-12/P.No.37/7.6)

7.7 KSRB 7.7 : Providing and fixing in position in cement concrete 1:3:6 steel
glazed windows and ventilators side hung/top hung fully openable as per
approved drawings using Z angles of 25x33x3mm, weighing 1.419 kg/m
both for outer and inner frames and central mullion section of size
25x46x3mm weighing 2.28 Kg/m duly providing T section 19x19x3mm
weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood
beading of required size, all steel sections should confirm to I.S. 7452 :
1990, 4nos, of holdfasts of approved size, section should be cut to length Sqm 3009.00
welded and electrically grinded subdividing frames of unit shall be
tenonned and revetted into the frames electrically. All the steel surface
shall be throughly cleaned free of rust and painted with one coat of anti-
corosive paint and finishing with two coats of ready mix paint of approved
colour and make including cost of materials, fixtures, labour, and HOM of
machinery complete as per specifications. Specification No. KBS
7.12.1/7.12.2/7.12.3/7.12 (PWD SR 2011-12/P.No.37/7.7)

7.8 KSRB 7.8 : Providing and fixing in position in cement concrete 1:3:6 steel
glazed windows and ventilators side hung/top hung 2/3 openable 1/3 fixed
as per approved drawings using Z angles of 25x33x3mm, weighing 1.419
kg/m both for outer and inner frames and central mullion section of size
25x46x3mm weighing 2.28 Kg/m all duly providing T section 19x19x3mm
weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood
beading of required size, all steel sections should confirm to I.S. 7452 :
1990, 4nos, of holdfasts of approved size, section should be cut to length
Sqm 2544.00
welded and grinded electrically subdividing frames of unit shall be
tenonned and revetted into the frames electrically. All the steel surface
shall be throughly cleaned free of rust and painted with one coat of anti-
corosive paint and finishing with two coats of ready mix paint of approved
colour and make including cost of materials, fixtures, labour, and HOM of
machinery complete as per specifications. (PWD SR 2011-12/P.No.37/7.8)
7.9 KSRB 7.9 : Providing and fixing M.S. grill work for windows and ventilators
weighing 21 kg/sqm using M.S. flats, or M.S. square rods, ro combination
of M.S. flats and square rods as per approved design, drawing including
cutting steel sections and welding the same to required pattern with a coat
of red lead primer, cost of materials, fixtures, labour and and HOM of Kgs 75.00
machinery complete as per specifications. Specification No. KBS 7.12.
(PWD SR 2011-12/P.No.37/7.9)

7.10 KSRB 7.10 : Providing and fixing in position anodized aluminium windows
and ventilators as per approved drawings with sliding shutters using
double track window frame section of size 61.85x31.75mm. with 1.2mm
thick, bottom section weight 0.659 kg/m, sides and top sections 1.3mm
thick weight 0.659 kg/m: and shutter comprising top and bottom section of
size 40mm x 18mm, 1.25mm thick 0.417 kg/m, shutter outer side 40mm x
18mm, 1.25mm thick weight 0.417 kg.m, shutter interlock section 40mm x
26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon
rollers with approved quality of fixtures such as aluminium handles tower
bolts etc., and providing and fixing 5.5mm. thick plain glass for shutters
fitted with rubber beading aluminium sections anodised 12 to 15 microns,
including cutting to required length, joints mitred subdividing the frame
tenonned and rivetted in the assembled frame stiffened with end clips at
Sqm
corners angles etc., and fixed to the walls, lintels, floor beams/cills as the
case may be with necessary steel screws, raul plugs, or teak wood gatties
including

cutting masonry or concrete and making good theoriginal surface using


cement mortar, aluminium sections pretreated for removal of any rust and
protection of further rust formation and coated with the greasy materials for
non-adhesion of mortar and any other sticky materials, (this coating should
be cleaned after installation) including cost of all materials, fixtures, labour
and HOM of machinery complete as per specifications. (PWD SR 2011-
12/P.No.37/7.10)

7.10.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
12/P.No.38/7.10.1) Sqm 2902.00

7.10.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 3000.00
quality (PWD SR 2011-12/P.No.38/7.10.2)
7.11 KSRB 7.10 : Providing and fixing in position anodized aluminium windows
and ventilators as per approved drawings with sliding shutters using
double track window frame section of size 92.00xx31.75mm. with 1.3mm
thick, bottom section weight 1.07 kg/m, sides and top sections 1.3mm thick
weight 0.933 kg/m: and shutter comprising top and bottom section of size
40mm x 18mm, 1.25mm thick 0.417 kg/m, shutter outer side 40mm x
18mm, 1.25mm thick weight 0.417 kg.m, shutter interlock section 40mm x
26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon
rollers with approved quality of fixtures such as aluminium handles tower
bolts etc., and providing and fixing 5.5mm. thick plain glass for shutters
fitted with rubber beading aluminium sections anodised 12 to 15 microns,
including cutting to required length, joints mitred subdividing the frame
tenonned and rivetted in the assembled frame stiffened with end clips at Sqm
corners angles etc., and fixed to the walls, lintels, floor beams/cills as the
case may be with necessary steel screws, raul plugs, or teak wood gatties
including

cutting masonry or concrete and making good theoriginal surface using


cement mortar, aluminium sections pretreated for removal of any rust and
protection of further rust formation and coated with the greasy materials for
non-adhesion of mortar and any other sticky materials, (this coating should
be cleaned after installation) including cost of all materials, fixtures, labour
and HOM of machinery complete as per specifications. (PWD SR 2011-
12/P.No.38/7.11)

7.11.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
Sqm 3016.00
12/P.No.38/7.11.1)

7.11.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 3100.00
quality (PWD SR 2011-12/P.No.38/7.11.2)

7.12 KSRB 7.12 : Providing and fixing in position anodized aluminium windows
and ventilators as per approved drawings with sliding shutters using four
track window frame of size 122.2x31.75mm. for bottom section 1.1mm
thick weight 1.205 kg/m, sides and top sections 1.2mm thick weight 1.093
kg/m: shutter section comprising top and bottom section of size 40mm x
18mm, wall thickness 1.25mm weight 0.417 kg/m, shutter side outer
40mm x 18mm, wall thickness 1.25mm weight 0.417 kg.m, shutter
interlock section 40mm x 26.7mm wall thickness 1.1mm thick, weight
0.469 kg/m. the shutters mounted on nylon rollers with approved quality of
fixtures such as aluminium handles tower bolts etc.; providing and fixing
5.5mm. thick plain glass for shutters fitted with rubber beadingaluminium
sections anodised 12 to 15 microns thick including cutting to required
length, joints mitred subdividing the Sqm
Sqm

frame tenonned and rivetted in the assembled frame to be stiffened with


end clips for corners, angles etc., and fixed to the walls, lintels, floor
beams/cills as the case may be with necessary steel screws, raul plugs, or
teak wood gatties including cutting masonry or concrete and making good
the original surface using cement mortar, aluminium pretreated for removal
of any rust and coated with greasy materials for non-adhesion of mortar
and any other sticky materials, (this coating should be cleaned after
installation) including cost of all materials, fixtures, labour and HOM of
machinery complete as per specifications. (PWD SR 2011-
12/P.No.38/7.12)

7.12.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
Sqm 2666.00
12/P.No.39/7.12.1)

7.12.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 2760.00
quality (PWD SR 2011-12/P.No.39/7.12.2)

7.13 KSRB 7.11 : Providing and fixing anodized aluminium casement windows
combination of foxed glazing at top fully openable windows using Z
sections of 33 mm, web thickness 4mm, weight 0.663 kg/m, central mullion
section 59 x 33mm with web thickness 3mm section weight 1.123kg/m the
shutters on aluminium hinges with aproved quality of fixtures such as
aluminium tower board, handles, stays etc., providing and fixing 5.5mm
plain glass for shutters fitted with glazed clips 19mm x 17.3mm x11mm.
0.9mm thick and rubber beading aluminium sections anodized to 12 to 15
microns cutting to required length, joints metered subdividing the frame
tennoned and rivetted, assembled frame to be stiffened with end clips at
corner, Sqm

angles and fixed to wall, lintel beam, floorcill as the case may be with
nessesary screws, rawl plugs, cutting masonry or concrete and making
good the original surface aluminium easy materials for non -adherence of
mortar or any other sticky materials (coating removed after installation)
through the cleaned free from dust etc., including cost of mateirals,
fixtures, labour, and HOM masonry complete as per specifications.

(PWD SR 2011-12/P.No.39/7.13)

7.13.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
Sqm 3410.00
12/P.No.39/7.13.1)

7.13.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 3500.00
quality (PWD SR 2011-12/P.No.39/7.13.2)
7.14 KSRB 7.14 : Providing, fabricating, assembling and fixing in position
anodized aluminium partitions using sections in combination of plain,
single grove and double grove as per requirements for the frames of
overall size 101.6mm x 44.45mm, 3.18mm. thick having section weight,
plain section 2.40kg/m, single grove section 2.541 kg/m and double grove
section 2.683kg/m and bottom member 114.3 mm x 44.45mm. 3.18mm.
thick weight 2.646 kg/m; aluminium louvers of size 77.6mm x 27.6mm
1.7mm. thick section weight 0.483 kg/m bottom portions provided with
12mm. thick prelaminated sheet both side of approved colour lamination
exterior grade aluminium sections of mat finish or glossy finish using
section, spacing of vertical member shall not exceed 0.6 m. c to c; sections
are cut to the required lengths, joints mitered and corners grinded
subdividing frames tennoned and rivetted to the frames, the assembled
frame should be stiffened with corner angles stripped and fixed with
screws, rawl plugs and teak wood gutties to RCC columns or masonry on
sides, RCC lintels or beams at top and floor at bottom, including cutting
chistling and making

Sqm

good with cement mortar to match the surface providing and fixing bottom
panel filled with the materials to a height of 0.9m from floor level; and
5.5mm, thick plain glass for middle portion viz., 0.9m to 2.13m and top
panel with lower sections, the glass and panels fitted with glazing clips of
19mm x 17.3mm with thickness of 0.9mm weight 0.124 kg/m; aluminium
sections anodised 12 to 15 mirons, sections pretreated for removal of any
rust and prevention of further rust formation, and coated with greasy
materials for non- adherence of mortars or any other sticky materials;
vertical members embedded in the flooring by making suitable size holes
and fixing with cement mortar, with necessary opening for fixing of doors of
standard size (excluding cost of door opening) All the frame should be
throughly cleaned free from rust, scale or dirt including cost of materials,
fixtures, labour and HOM of machinery complete as per specifications.
(PWD SR 2011-12/P.No. 39/7.14)

7.14.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
Sqm 3731.00
12/P.No.40/7.14.1)

7.14.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 3830.00
quality (PWD SR 2011-12/P.No.40/7.14.2)
7.15 KSRB 7.15 : Providing, fabricating, assembling and fixing in position
anodized aluminium partitions using aluminium sections of mat finish or
glassy finish in combination of plain grove, single grove and double grove
as per requirements for the frames of overall size 63.5mm x 38.1mm. with
thickness of 2mm. having section weight, plain section 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094 kg/m and double grove
thickness 1.9mm section weight 1.094kg/m and bottom member 114.3 mm
x 44.45mm. thickness 3.18mm. weight 2.646 kg/m; aluminium louvers
section of size 36.5mm x 34.93mm 1.45mm. thick section weight 0.429
kg/m bottom portions provided colour lamination exterior grade upto
0.9mheight, spacing of vertical membe not exceeding 0.6m c to c; sections
are cut to the required lengths, joints mitered to the frames; the assembled
frame stiffened with corner angles, stripped and fixed with screws, rawl
plugs and teak wood gutties to RCC columns on sides RCC lintels or
beams at top and floor at bottom, including cutting chistelling and making
good with cement mortar to match
Sqm

the surface; providing and fixing 5.5mm. thick plain glass for middle portion
viz., 0.9m to 2.13m and top panel with louver sections; the glass and
panels fitted with glazing clips of 19mm x 17.3mm. of thickness 0.9mm.
weight 0.124kg/m, aluminium sections anodised 12 to 15 microns, sections
treated for removal fo any rust and prevention of further rust formation,
coated with greasy materials for non-adherence of mortars or any other
sticky materials; vertical members embedded in the flooring by making
suitable sized holes and fixing with cement mortar, with necessary opening
for fixing of door of standard size (excluding cost of door) all the frame
throughly cleaned, free from rust, scale or dirt including cost of mateirals,
fixtures, labour and HOM of machinery complete as per specifications.
(PWD SR 2011-12/ P.NO.40/7.15)

7.15.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
Sqm 2518.00
12/P.No.41/7.15.1)

7.15.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 2600.00
quality (PWD SR 2011-12/P.No.41/7.15.2)

7.16 KSRB 7.15 : Providing, fabricating, assembling and fixing in position


anodized aluminium shutters to the existing dooe frame in the partition
using using 47.62 x 44.45mm section thickness 3.18mm, weight 1.505
kg/m for vertical frame; 47.62 x 44.45 thickness of 3mm, weight 1.42 kg/m
for top section, 49.91mm x 44.45mm with wall thickness 3mm, weight
1.495 kg/m for central rail; and114.3mm x, plain section 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094 kg/m and double grove
Sqm
thickness 1.9mm section weight 1.094kg/m and bottom member 114.3 mm
x 44.45mm. thickness 3.18mm. weight 2.646 kg/m for bottom rail;
aluminium sections anodized 12 to 15 microns and cut to lenght joint
metred and corners grinded, the bottom rail and top rail hinged or pivoted,
opening arrangements including providing and
fixing standard approved accessories, such as aluminium handles, tower
bolts, lock, pivots; hinges PVC or rubber gasket, 12mm prelaminated
sheets (Novopan) extetior grade of approved colour both sides same
colour for bottom panel of maximum height 0.90m and 5.5 mm thick plain
glass for top panel (Novopan) and glass fixed with glazed clips
19mmx11mm, 0.9mm thick, weight 0.124 kg/m. aluminium sections treated
for removal of any rust and prevention of further rust formation, and
coated with greasy materials for non-adherance of mortars or any other
stickly materials, including cost of materials, fixtures, labour and HOM of
machinery complete as per specification.(PWD SR 2011-12/P.No.
41/7.16)

7.16.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
12/P.No.41/7.16.1) Sqm 3071.00

7.16.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 3170.00
quality (PWD SR 2011-12/P.No.41/7.16.2)

7.17 KSRB 7.17 : Providing, fabricating, assembling and fixing in position


anodized aluminium doors using following aluminium mat finish, outer
frame plain section 101.6x44.45mm thickness 3.18mm, section weight
2.404 kg/m door shutters vertical section 44.62 x 44.45mm thickness
3.18mm, section weight 1.505 kg/m top section, 47.62 x 44.45mm
thickness 3.00mm, section weight 1.426 kg/m bottom section114.3x44.45
thickness 3.18mm,section weight 2.646kg/m door central section
49.91x45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips
19x17.3x11mm thickness 0.9mm section weight 0.124 kg/m; aluminium
sections anodized 12 to 15 microns cut to lenght joint metred corners
grinded, the shutters pivoted opening arrangement with heavy duty
aluminium alloy automatic door closures floor mounted, providing and
fixing standard approved accessories, such as aluminium handle for full
width or length, tower bolts, lock, pivots: PVC or rubber gasket with 5.5m.
thick plain glass for top and bottom panel; aluminium sections treated for Sqm
removal of any rust and preventon of further rust formation, and coated
with greasy materials for non-adherance of mortars or any other sticky
materials; the

assembled frame fitted with the corner angles, strips and fitted with
screws, rawl plugs or teakwood gutties to RCC columns or masonry on
sides. beams and flooring in botton. including cutting, chistling and making
good with cement mortar to match the surface; all the frames throughly
cleaned free from rust, scale or dirt including cost of materials, fixtures,
labour and HOM of machinery complete as per specifications. (PWD SR
2011-12/P.No. 41/7.17)

7.17.1 -do- using aluminium section anodized to 12-15 microns. (PWD SR 2011-
12/P.No.42/7.17.1) Sqm 4570.00

7.17.2 -do- using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Sqm 4670.00
quality (PWD SR 2011-12/P.No.42/7.17.2)
7.18 Providing and fixing of Aluminium composite panel of approved make and
colour for wall cladding for straight Brick/RCC/Stone walls &
coloumns/beams with necessary aluminium frame works at required level
made out of 50x25x3mm 'C' section or equalent. The panel should consist
of 2.5mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminiumsheet making a total panel thickness of 3mm. The
surface coating on reverse sides would be in polyester paint. The system
shall be fixed using GI brackets, aluminium L cleats and stainless steel Sqm 4405.00
bolts and nuts complete with spring washer and cap nuts and all other
necessary accessories, sealing shall be done using weather sealant of
Dow Corning 789 with necessary rods etc., complete. (PWD SR 2011-
12/P.No. 42/7.18)

7.19 Providing and fixing of Aluminium composite panel of approved make and
colour for wall cladding for curved Brick/RCC/Stone walls &
coloumns/beams with necessary aluminium frame works at required level
made out of 50x25x3mm 'C' section or equalent. The panel should consist
of 2.5mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminium sheet making a total panel thickness of 3mm. The
surfaces will be finished with PVDF based coating on topsides and service
coating on reverse sides would be in polyester paint. The system shall be Sqm 4948.00
fixed using GI brackets, aluminium L cleats and stainless steel bolts and
nuts complete with spring washer and cap nuts and all other necessary
accessories, sealing shall be done using weather sealant of Dow Coring
789 with necessary rods etc., complete. (PWD SR 2011-12/P.No. 42/7.19)

7.20 Providing, Fabricating and fixing of stick type structural glazing using
Alluminium Extrusions of 63.5 mm x 58.00 mm x 2.25mm of 1.73 kgs/mtr
for vertical and Horizontal members and 63.5mm x 38.1 x 1.33mm of
0.759 kg/mtr, as outer frame with Electro Anodized Paint coated block
finishing, using 6mm thick imported glass reflective hard coated ocean
blue raw glass with all necessary accesories like ultra glass Silicon sealant
of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, Sqm 4985.00
6mm thick M.S angle 50mm x 150mm x 6mm M.S Galvanized L Brackets,
structural sealent setting clocks, fasteners, wall connection etc., complete.
(PWD SR 2011-12/P.No. 42/7.20)

7.21 Providing fusion bonded epoxy coating not less than 175 microns
thickness and upto 300 microns to reinforcement of all diameters as per
IS: 13620-1993 including testing of coating at plant. The rate is inclusive of
cost on account of careful handling, PVC coated binding wire instead of GI
Binding wire, touch up material supplied by coating agency, repair work,
loading, unloading and straightening of bent rods etc., complete as per
specification and as directed by the Engineer in charge. (inclusive of all
taxes but excluding transportation charges). (PWD SR 2011-12/P.No.
43/7.21)
7.21.1 -do- For 10mm to 16mm dia bars (PWD SR 2011-12/P.No.43/7.21.1) Tonne 11000.00

7.21.2 -do- For 20mm to 32mm dia bars (PWD SR 2011-12/P.No.43/7.21.2) Tonne 8000.00

7.22 Providing, fabricating, assembling and fixing in position anodized


aluminium partition using 101.60mm x 44.45mm x 3.18mm aluminium,
mate finish or glossy finish, anodized sections combination of plain, single
groove and double groove members should not exceed 0.60 mc/c and
bottom member of required lengths, joints mitred and corner grinded sub
dividing assembled frame should be stiffened with corner angles. Stripped
and fixed with screws rawl plug and teakwood guttas to RCC column or at
bottom; including cutting chistelling and making good with cement mortar
to match the surface. Providing and fixing 12mm. thick prelaminated sheet
(Ecoboard - exterior grade) of approved colour for bottom panel of
maximum height 0.9m, and 5.50 mm thick plain or pin headed glass for
middle panel and top panel with glazing clips of 19.05mm x 17.30mm x
1.00mm. All the aluminium sections used should be treated for removal of Sqm
any rust and prevention of further rust formation and coated with materials:
The vertical members should be embedded in the flooring by making
suitable size holes and fixing with cement mortar. All the frame should be
thoroughly cleaned free

from rust, scale or dirt. work should be carried out as per direction of
engineer-in-charge of the work with all lead and lift as per chief Architect's
drawing etc., complete ti a degree of perfection. (PWD SR 2011-
12/P.No.43 /7.22)

7.22.1 - do - using aluminium section anodized to 12-15 microns. (PWD SR


Sqm 2900.00
2011-12/P.No.43/7.22.1)

7.22.2 -do - using aluminium section powdered coated to a minimum of 60-70


microns with exterior durable pure polyester grade powder of approved Tonne 3000.00
quality (PWD SR 2011-12/P.No. 43/7.22.2)

7.23 Providing and fixing door frame with or without ventilator made out of cold
rolled steel section of thickness 1.25mm formed into section of 60mm x
105mm welded to form a rectangular door conforming to IS 513-1973 and
phosphated and painted and with one coat of red oxide primer, two coat of
approved enamel paints the frame work with 4nos. of hold fast of size
200x25x4mm fixed in cement concrete 1:3:6 of 20mm down size jelly and
4nos.of ISI marked hinges 125mm long welded to the frame and fixed with
shutter made out of Honne wood styles and rails of 30mm thick with Sqm 2200.00
panels of 12mm thcik 'Ecoboard' Plain Particle Board of exterior grade
conforming to IS-3087 excluding the cost of fixtures but including labour
charges for fixing of fixtures. The hollow portion of the frame to be filled
with C.C. 1:2:4 of 20mm down size jelly. (PWD SR 2011-12/P.No.
43/7.23)
7.24 Providing and fixing cold rolld prepainted steel windows of IS Standards,
made out of 0.30 mm thick deep drawing quality galvanised on both sides
120 gms/Sq.mtr. Primer coat upto 5 microns with thermosetting epoxy
resin and finish painted with a polyester based paint 20 microns thick. The
size of profiles is approximately 46 x 52 mm for external frames, 46 x 46
mm section for shutters, 46 x 70 mm section for centre mullion/transom
and 18 x 31 mm section is for fixing glasses. The section should be cut to
length joint mitred and assembling by means of conrner brackets made out
of cold rolled cold annealed strips of 1.20 mm thick duly galvanised and
fixed with nickle plated self taping fixtures like handles made out of glass Sqm
filled nylone and hinges made out of CRCA powder coated. 4 mm thick
glass should be fixed with EPDM gaskets. Guard bars fabricated out of 10
mm square bright bars shall be fixed horizontally at 125 mm /C by rivetting
to the external frame. The above frames are fixed to the concrete/masonry
walls by means of self expanding screws.(PWD SR 2011-12/P.No.44/7.24)

7.24.1 a) -do- with 4mm float glass without guard bars Sqm 3520.00
b) -do- with 4mm tinted glass without guard bars Sqm 3600.00
c) -do- with 4mm float glass without guard bars Sqm 4000.00
d) -do- with 4mm tinted glass with guard bars Sqm 4250.00

7.25 Providing and fixing cold rolled prepainted steel partitions of IS standards,
made out of 0.6mm of deep drawing quality galvanised on both sides
120gms/Sq.mtr. Primer coated upto 5 microness with thermosetting epoxy
resin and finish painted with a polyester based paint 20 micrones thick.
The size of profiles is 46 x 52mm for external frame, section for mullion or
transom is of size 46 x 70mm and section for fixing glass/ board is of 18 x
31mm. The section should be cut to length joint mitredc and assembling by
means of corner brackets made out of cold rolled cold annealed strips of Sqm
1.2mm thick duly galvanised and fixed with nickle plated self taping
screws. 5mm thiock glss should be fixed with EPDM gaskets. 10mm thick
prelaminated particle board shll be fixed with the help of the clipping bead.
The above frames are fixed to the concrete/ masory walls and floors by
means of self expanding screws.(PWD SR 2011-12/ P.No.44/7.25)

7.26 Supplying and fixing pressed steel door frames size 125 x 65mm
manufactured from 1.25mm thick carbon steel or imported steel strips with
mitred joints of 900 for door 'opening and shutters made out of seasoned
Honne wood, styles of 300mm, thick with lock rail of 160mm, width, top
and side rails of 100mm. width and bottom rails of 250mm width and panel
filling with 12mm thick particle board of exterior grade bonded with phenol
formal heat resistant guaranteed against shrinkage, warpage and such
other defects for a period of 3 years. This shall be as per approved
drawings, specification and direction including cost of conveyance, Sqm 3500.00
manufacturing, painting with enamal paint 2 coats over primer coat, cost of
labour for all items of work, machinary, equipment and all other incidental
charges with all lead, lift, loading and unloading etc., complete. The Hollow
portion of the frame to be filled with cement concrete 1:2:4 (PWD SR
2011-12/P.No.45/7.26)
7.27 Supplying and fixing pressed steel window frame of size 100 x 50mm
manufactured from 1.25 mm thick carbon stel or imported steel strips with
neat mitred joints at 900 degree for window opening and shall be suitable
to fix M.S. grills as per design and drawings using 12 mm dia rods at 100
mm Centre to Centre horizontally and two members of M.S flates of 6mm x
40 mm size at 150 mm apart, welded into a frame of 6 mm x 40 mm size
M.S. flates with 16mm size lugs, and 8 Nos.of 100mm size hinges, 4 Nos
of Butt Stay pins and 4 Nos. Tower bolts and shutters half panalled and
half glazed with shutters made out of seasoned honne wood, styles of 30
mm thick and 100mm width and rails of 30mm thick and 100mm width and
using 4mm thick pin headed glass and panel, fillling with 12mm thick
particle board of exteior grade with phenol formaldehyde resinand the Sqm 3800.00
shutter shall be rot proof vermin proof, heat resistant guranteed aginst
shrinkage, wrapage and such other defects for a period of 3 years.

This shall be as per approved drawing, specification and direction


including cost of conveyance, manufacturing painting with 2 coats enamal
paint over one coat of primer, cost of labour for all items of work,
machinary, equipment and all other incidental charges with all lead, lift
loading unloading etc., complete. The Hollow portion of the frame to be
filled with cement concrete 1:2:4. (PWD SR 2011-12/ P.No. 45/7.27

7.28 Providing electric welding using carbon electrodes including cost of


welding machine, power charges, welding rods, and labour charges for
cm 2.00
welding etc., complete as per specification. (PWD SR 2011-12/ P.No.
45/7.28)

7.29 Fabricating, supplying and top erecting M.S. tublar Truss of Span upto
10m. The bottom and top member is provided with 50x50x6mm double
equal angles, welded back and in between top and bottom line, in areas of
mid section is provided with 50x50x6mm equal single angle for vertical and
inclined members and at supporting ends 40x40x5mm single angle is
provided. All the members are welded together with 6mm gusset plate as
per Drawing. The entire truss is anchored in RCC column by using 4 Nos.
of M.S. anchor bolts at each support, with 10mm thick base plate and shoe
plate. The work includes cutting, straightening, placing in position of M.S. Kgs 103.00
angle and welding wherever necessary, and applying one coat of red oxide
primer coat to all members including cost of all materials, labour charges,
and hire charges of machineries for cutting, welding,grinding and erection
equipments, with all lead and lift, transportation, etc., complete as per
specification. (PWD SR 2011-12/ P.No. 45/7.29)

7.30 Fabricating, supplying and top erecting M.S. Angular Truss for all spans as per
approved design and drawing. The entire truss is anchored in RCC column by
using 4 Nos. of M.S. anchor bolts at each support, with base plate and shoe plate.
The work includes cutting, straightening, placing in position of M.S. angle and
welding wherever necessary, and applying one coat of red oxide primer coat to all Kgs 121.00
members including cost of all materials, labour charges, and hire charges of
machineries for cutting, welding,grinding and erection equipments, complete as per
specification. (P.No. 41/7.30)
7.31 Fabricating, providing and erecting in poiston of M S ornamental security
Grill Gate without hot dip using 75x12mm MS flat for alround frame work
with verticals at the centre and horizontal centre support MS Sqare of
20x20 mm of different heights as shown in the Drawing are to be fixed at
16 cms C/C for square bars of full height and at 8cms C/C for bottom rods
providing ornamental CI Designers at the botom and CI arrows in the
middle and top. The entire frame work is to be fixed by means of
expansion bolts to the brick pillars with necessary drilling holes. the work
includes providing two coats of enamel painting overone coat of red lead Kgs 119.00
ready mix primer coat etc complete cost of all labour, painting, erection
charges using hoist pulleycranes with all lead and lift, loading and un
loading using hoist pulley cranes, scaffolding charges and all other
incidental charges required for successfull completion to the work as per
specification and Drawings. (PWD SR 2011-12/ P.No. 46/7.31)

7.32 Fabricating, providing and erecting in poiston of HOT dip galvanised M.S.
Ornamental security Grill Gate using 75x12mm MS Flat for alround frame
work with verticals at the centre and horizontal centre support MS Square
of 20x20mm of different heights as shown in the Drawing are to be fixed at
16 cms C/C for square bars of full height and at 8 cms C/C for bottom rods
providing ornamental CI Desighners at the bottom and CI arrows in the
midle and top. the entire frame work is to be fixed by means of expansion Kgs 135.00
bolts to the brick pillars with necessary drilling holes. The work includes
providing two coats of enamel painting over one coat of red lead ready mix
primer coat etc., complete cost of all labour, painting, erection charges
using hoist pulleycranes etc as per specification and drawings. (PWD SR
2011-12/ P.No. 46/7.32)

7.33 Fabricating, providing and erecting in poiston of M S ornamental security


Grill Gate without hot dip using 75x12mm MS flat for alround frame work
with verticals at the centre and horizontal centre support MS Sqare of
20x20 mm of different heights as shown in the Drawing are to be fixed at
16 cms C/C for square bars of full height and at 8cms C/C for bottom rods
providing ornamental CI Designers at the botom and CI arrows in the
middle and top. The entire frame work is to be fixed by means of Kgs 119.00
expansion bolts to the brick pillars with necessary drilling holes. the work
includes providing two coats of enamel painting overone coat of red lead
ready mix primer coat etc complete cost of all labour, painting, erection
charges using hoist pulleycranes etc., as per specification and Drawings.
(PWD SR 2011-12/ P.No. 46/7.33)
7.34 Fabricating, providing and erecting in poiston of Hot dip galvanised M S
Ornamental security Grill using 75 x 12mm M S Flat for alround frame work
with verticals at the centre and horizontal centere support M S Square of
20 x20 mm of different heights as shown in the drawing are to be fixed at
16 cms C/C for suqare bars of full height and at 8cms C / C for bottom
rods providg ornamental C I Designers at the botom and C I arrows inthe
midle and top. The entire frame work is to be fixed by means of expansion
bolts to the brick pillars with necesary drillling holes, the work includes
providng two coats of enamel painting over one coatr of red lead ready mix Kgs 144.00
primer coat etc complete cost of all labour, painting, erection charges
using hoist pulleycranes with all lead and lift, loading, transporting and
unloading using hoist pulley cranes, scaffolding charges and all other
incidental charges required for successful completion fo the work as per
specification and drawings, (PWD SR 2011-12/ P.No. 47/7.34)

7.35 Providing and fixing M.S. Hand railing for Balcony with 50mm dia. M.S.
hollow pipe of 14 gauge, welded to 20mmx20mm M.S. square rod placed
vertically, spaced at 100mm at regular intervals of 600mm. These vertical
rods laterally tied to 3 horizontal rods spaced at equal interval. These
assembly is fixed to concrete by using expansion bolts and welding the
same to reinforcement bars and making good the surface. All the joints
and sections hould be cut to length, welded and grinded wherever Sqm 2095.00
necessary etc., complete. The work includes cost of all materials, labour
charges for all items of work, hire charges for welding, cutting and grinding
equipment, and electricity charges, etc., complete as per specification and
drawing. (PWD SR 2011-12/ P.No. 47/7.35)

7.36 Providing and fixing M.S.Grill over existing compound wall as per Chief
Architect drawing No. 12686, using 16mm x 16mm M.S.Square rod at
150mm c/c spacing and 6mm x 40mm M.S. flats at horizontal and 6mm
x12mm M.S. flat for ornamental design and providing shop edge design at
the vertex of every vertical rods, including welding, grinding wherever
necessary. All the steel surface should be thoroughly cleaned free of rust
and painted with anti corrosive paint (shop paint) etc., complete. The work Sqm 4523.00
includes cost of all materials, labour charges for all items of work, hire
charges for welding, cutting and grinding equipment, and electricity
charges, etc., complete as per specification.(PWD SR 2011-12/ P.No.
47/7.36)
7.37 Providing and fixing M.S. Gate as per Chief Architect Drawing, using
50mm x 50mm 14 guage M.S. hollow pipe frame work bent to ornamental
shape as shown in the drawing and 35mm x 6mm and 16 x 16mm Square
rods for verticals alternatively spaced at 4cms c/c in two halves and
40mmx6mm M.S. flats for horizontal member and at the top cast iron
spikes are provided at alternate vertical members as shown in the drawing
etc., complete. All the steel surface should be throughly cleaned free of
Sqm 2428.00
rust and painted with anti crrosive paint (Shop Paint) etc., complete. the
work includes cost of all materiels, labour charges for all items of work, hire
charges, for welding, cutting and grinding equioment, and electricity
charges, with lead and lift, loading and un loading charges, etc., complete
as per specification.(PWD SR 2011-12/ P.No. 47/7.37)

7.38 Providing and fixing Stainless steel staircase railing as per chief Architect
Drawing NO. 11520/ HRSC with hand rail 50mm dia 16 guage hallow pipe
welded to vertical hollow 50 mm dia pipe of 16 guage, stainless steel
vertical pipe spaced at 1.20m regular intervals, and 5 Nos of 25mm dia.
stainless steel hollow horizontal pipe are welded to vertical 50mm dia
Sqm 5219.00
hollow pipe. The entire assembly is fixed to staircase concrete by using
expansion bolts by drilling concrete etc., complete including cost of
materials, labour, HOM of machineries and electrical charges, etc.,
complete as per specifications. (PWD SR 2011-12/ P.No. 48/7.38)

7.39 Providing and fixing 304-grade stainless steel hand rails of 14-guage pipes
for Ramps or Staircase are made out of stainless steel hallow pipes, using
50mm dia for verticals @ 1.60 mtr C/C are fixed to he ramps or steps by
drilling with bolts and 100mm dia MS base plates 10mm guage for fixing of
vertical pipes 4-Nos anchor bolts & 40mm dia pipes are fixed horizontally
for 2-rows top, one pipes are fixed with vertical pipes another one are
fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows
below top measure @ equal intervals including cutting, welding, bending
wherever necessary with suitable caps @ tops, bottoms & corners
finishing with mat / shining etc., complete including cost and conveyance Sqm 5222.00
of all materials, labour for all items of work, HOM of equipment with all lead
and lift, loading and un loading, transportation charges and all other
incidental charges etc., complete as per specification and directions of the
Engineer-in-charge of the work. Ramps or Staircase for physically
challenged. (PWD SR 2011-12/ P.No. 48/7.39)
ROOFING
8.1 KSRB 8.1 : Providing and fixing in position stone slab roofing 10 to 12 cms
thick laid to line and level over wooden rafters or RCC battens, pointing
exposed joints with cement mortar 1:4 including cost of materials, labour,
curing complete as per specifications. (wooden rafters and RCC batters to Sqm 446.00
be paid seperately) (PWD SR 2011-12/P.No. 51/8.1)

8.2 KSRB 8.2 : Providing and fixing in position black cuddapah slab /
Shahabad Slab/Thandur blue slab 4 cms thick for roofing laid to line and
level over wooden rafters or RCC battens pointing exposed joints with
cement mortar 1:4 including cost of materials, labour, curing complete as
Sqm 382.00
per specifications. (Wooden rafters and RCC battens to be paid
seperately) (PWD SR 2011-12/P.No. 51/8.2)

8.3 KSRB 8.3-1 : Providing and laying to required line and slope roofing with
corrugated asbestos cement sheet 6mm, thick fixed with galvanised iron J
or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over
the existing purlins, rafters and trusses including cost of materials, labour, Sqm 299.00
complete as per specification, Specification No. KBS 8.5 (PWD SR 2011-
12/P.No. 51/8.3)

8.4 KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 (1 cement
: 15 cinderof 12.5mm nominal gauge) on terraced roof of sunken slabs,
laid to slope compacting, including cost of materials, labour, curing cum 1489.00
complete as per specification, (PWD SR 2011-12/P.No.51/8.4)

8.5 KSRB 8.6-1 : Providing and fixing on wall surface cast iron rain down
water pipes 75mm dia including filling the joints with spunyarn soaked in
neat cement slurry 1:2 with necessary specials like shoes, bends and
offsets fixed with iron clamps, wall plugs, screws, including cost of m 846.00
materials, labour, complete as per specification, (PWD SR 2011-12/P.No.
51/8.5)

8.6 KSRB 8.3-2 : Providing and laying to required line and slope roofing with
semi-corrugated (Trafford) asbestos cement sheet 6mm, thick fixed with
galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and
bitumen washers over the existing purlins, rafters and trusses including Sqm 325.00
cost of materials, labour, complete as per specification, (PWD SR 2011-
12/P.No. 51/8.6)

8.7 KSRB 8.3-3 : Extra for A.C Sheet corrugated / semi-corrugated sheet
roofing with vertical sheeting to a pitch exceeding 60 degrees (PWD SR Sqm 7.00
2011-12/P.No. 51/8.7)
8.8 KSRB 8.3-4 : Providing and fixing ridges, hips with asbestos cement sheet
rooting with G.I. J or L hooks, bolts and nuts 8mm. dia G.I. Plain and
bitumen washers, serrated or plain wings, adjustable ridges, including cost m 233.00
of materials, labour, complete as per specification, (PWD SR 2011-
12/P.No. 51/8.8)

8.9 KSRB 8.3-5 : Providing and fixing northlight adjustable ridges, hips with
asbestos cement sheet rooting with G.I. J or L hooks, bolts and nuts 8mm.
dia G.I. Plain and bitumen washers, serrated or plain wings, adjustable m 198.00
ridges, including cost of materials, labour, complete as per specification,
(PWD SR 2011-12/P.No. 51/8.9)

8.10 KSRB 8.4-1 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips teak wood reepers of
size 50 x 25mm and pointed with cement mortar 1:4 over the existing
rafters including cost of materials, labour, complete as per specification. Sqm 760.00
Specification No. KBS 8.17 (PWD SR 2011-12/P.No. 52/8.10)

8.11 KSRB 8.4-2 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips nandi wood reepers of
size 50 x 25mm and pointed with cement mortar 1:4 over the existing
rafters including cost of materials, labour, complete as per specification. Sqm 636.00
Specification No. KBS 8.17 (PWD SR 2011-12 P.No. 52/8.11)

8.12 KSRB 8.4-3 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips jungle wood reepers of
size 50 x 25mm and pointed with cement mortar 1:4 over the existing
rafters including cost of materials, labour, complete as per specification. Sqm 521.00
Specification No. KBS 8.7 (PWD SR 2011-12/P.No. 52/8.12)

8.13 KSRB 8.6-3 : Providing and fixing on wall surface cast iron rain down
water pipes 100mm dia including filling the joints with spun yarn soaked in
neat cement slurry 1:2 with necessary specials like shoes, bends and
offsets fixed with iron clamps, wall plugs, screws, including cost of m 945.00
materials, labour, curing complete as per specification. Specification No.
KBS 8.25, 8.26 (PWD SR 2011-12/P.No. 52/8.13)

8.14 KSRB 8.6-3 : Providing and fixing on wall surface asbestos cement rain
down water pipes 75mm dia including filling the joints with spun yarn
soaked in neat cement slurry 1:2 with necessary specials like shoes,
bends and offsets fixed with iron clamps, wall plugs, screws, including cost m 289.00
of materials, labour, curing complete as per specification. Specification No.
KBS 8.26, 8.27 (PWD SR 2011-12/P.No. 52/8.14)
8.15 KSRB 8.6-4 : Providing and fixing on wall surface asbestos cement rain
down water pipes 100mm dia including filling the joints with spun yarn
soaked in neat cement slurry 1:2 with necessary specials like shoes,
bends and offsets fixed with iron clamps, wall plugs, screws, including cost m 329.00
of materials, labour, curing complete as per specification. Specification No.
KBS 8.26, 8.27(PWD SR 2011-12/P.No. 52/8.15)

8.16 KSRB 8.6-5 : Providing and fixing on wall surface 2.5kg/ sq.cm H.D.P.E.
rain down water pipes 90mm dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps, m 304.00
wall plugs, screws, including cost of materials, labour, curing complete as
per specification. (PWD SR 2011-12/P.No. 52/8.16)

8.17 KSRB 8.6-6 : Providing and fixing on wall surface 2.5kg/ sq.cm H.D.P.E.
rain down water pipes 110mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps,
wall plugs, screws, including cost of materials, labour, curing complete as m 364.00
per specification. (PWD SR 2011-12/P.No. 52/8.17)

8.18 KSRB 8.6-7 : Providing and fixing on wall surface 4.0 kg/ sq.cm H.D.P.E.
rain down water pipes 90 mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps,
wall plugs, screws, including cost of materials, labour, curing complete as m 324.00
per specification. (PWD SR 2011-12/P.No. 52/8.18)

8.19 KSRB 8.6-8 : Providing and fixing on wall surface 4.0kg/ sq.cm H.D.P.E.
rain down water pipes 110mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps,
wall plugs, screws, including cost of materials, labour, curing complete as m 441.00
per specification. (PWD SR 2011-12/P.No. 52/8.19)

8.20 KSRB 8.7-1 : Providing and fixing in position 10mm thick plaster of paris
(Gypsum anhydrous) for ceiling flat surface upto a height of 5m above floor
level over first class teakwood strips 25mm/6mm with 10mm gap in
between and reinforced with rabbit wire mesh fixed to wooden frames Sqm 1141.00
(frame work to be measured and paid for seperatly) including cost of
materials, labour, curing complete as per specification (PWD SR 2011-
12/P.No. 52/8.20)

8.21 KSRB 8.7-2 : Providing and fixing in position 10mm thick plaster of paris
(Gypsum anhydrous) for ceiling curved surface upto a height of 5m above
floor level over first class teakwood strips 25mm/6mm with 10mm gap in
between and reinforced with rabbit wire mesh fixed to wooden frames Sqm 1208.00
(frame work to be measured and paid for seperately) including cost of
materials, labour, curing complete as per specification (PWD SR 2011-
12/P.No. 52/8.21)
8.22 KSRB 8.7-3 : Extra over item No. 8.7-1 and 8.7-2 for any sunk or raised
moulded design plaster of paris (Gypsum anhydrous) ceiling (PWD SR Sqm 352.00
2011-12/P.No. 53/8.22)

8.23 KSRB 8.7-4 : Extra over item No. 8.7-1 and 8.7-2 for any providing plaster
of paris (Gypsum anhydrous) ceiling above 5 m height from floor level Sqm/m 71.00
(PWD SR 2011-12/P.No. 53/8.23)

8.24 KSRB 8.7-5 : Providing and fixing in position 12mm thick plaster of paris
(Gypsum anhydrous) for ceiling flat surface with ceiling tiles upto a height
of 5 m above floor level over wooden frames and rendered smooth with
plaster of paris (Frame work to be measured an paid for seperately) Sqm 665.00
including cost of materials, labour, curing complete as per specifications
(PWD SR 2011-12/P.No. 53/8.24)

8.25 KSRB 8.7-6 : Extra over item No. 8.7-5 for any providing plaster of paris
(Gypsum anhydrous) ceiling tiles above 5 m height from floor level (PWD Sqm/m 32.00
SR 2011-12/P.No. 53/8.25)

8.26 Providing top layer with 12 mm thick latex plaster with smooth finishing on
Sqm 360.00
top surface. (PWD SR 2011-12/P.No. 53/8.26)

8.27 Providing and fixing 6mm Bronze Multi Wall poly carbonate sheet for
Tubular stucture. The work including cost of all materials, labour charges,
and hire charges of machineries for cutting, welding, grinding and erection Sqm 2180.00
equipments, complete as per specification. (PWD SR 2011-12/P.No.
53/8.27)
WOOD WORK
9.1 KSRB 9.1 : Labour for providing Teak wood wrought and putup for purlins,
common rafters and similar work including cost of labour, HOM of
machineries complete as per specifications. Specification No. KBS 9.4 cum 2589.00
(PWD SR 2011-12/P.No. 55/9.1)

9.2 KSRB 9-2.1: Providing Honne wood wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM
of machineries complete as per specifications. Specification No. KBS 9.27 cum 71049.00
(PWD SR 2011-12/P.No. 55/9.2)

9.3 KSRB 9-2.2: Providing Mathi/Nandi wood wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM
of machineries complete as per specifications. Specification No. KBS 9.27 cum 59629.00
(PWD SR 2011-12/P.No. 55/9.3)

9.4 KSRB 9-2.3 : Providing Sal wood wrought and putup for purlins, common
rafters and similar work including cost of materials, labour, HOM of
machineries complete as per specifications. Specification No. KBS 9.27 cum 42498.00
(PWD SR 2011-12/P.No. 55/9.4)

9.5 KSRB 9-2.4: Providing Jungle wood such as Nerale, Neem wrought and
putup for purlins, common rafters and similar work including cost of
materials, labour, HOM of machineries complete as per specifications. cum 38215.00
Specification No. KBS 9.27 (PWD SR 2011-12/P.No. 55/9.5)

9.6 KSRB 9-3.1: Providing Teak wood class-II frames for false ceiling,
partitions etc., main battens of size 50 x 12.5mm at 60 cms. c to c and
cross battons 38mm x 50mm at 60 cms. c to c sawn and putup including Sqm 2617.00
cost of mateirals, labour, complete as per specifications. Specification No.
KBS 9.28 (PWD SR 2011-12/P.No. 55/9.6)

9.7 KSRB 9-3.2 : Providing Honne wood frames for false ceiling, partitions
etc., main battens of size 50 x 12.5mm at 60 cms. c to c and cross battons
38mm x 50mm at 60 cms. c to c sawn and putup including cost of Sqm 1281.00
mateirals, labour, complete as per specifications. Specification No. KBS
9.28 (PWD SR 2011-12/P.No. 55/9.7)

9.8 KSRB 9-3.3 : Providing Matti or Nandi wood frames for false ceiling,
partitions etc., main battens of size 50 x 12.5mm at 60 cms. c to c and
cross battons 38mm x 50mm at 60 cms. c to c sawn and putup including Sqm 1076.00
cost of mateirals, labour, complete as per specifications. Specification No.
KBS 9.28 (PWD SR 2011-12/P.No. 55/9.8)
9.9 KSRB 9-3.4 : Providing Sal wood frames for false ceiling, partitions etc.,
main battens of size 50 x 12.5mm at 60 cms. c to c and cross battons
38mm x 50mm at 60 cms. c to c sawn and putup including cost of Sqm 768.00
mateirals, labour, complete as per specifications. Specification No. KBS
9.28 (PWD SR 2011-12/P.No. 55/9.9)

9.10 KSRB 9-4.1: Providing Teak wood class-II frames of doors, windows,
clerestory windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves (excluding cost of cement
concrete and side clamps), but including cost of materials, labour, HOM of cum 145838.00
machineries complete as per specifications. Specification No. KBS 9.33
(PWD SR 2011-12/P.No. 55/9.10)

9.11 KSRB 9-4.2: Providing Honne wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps), but including cost of materials, labour, HOM of machineries cum 71604.00
complete as per specifications. Specification No. KBS 9.33 (PWD SR
2011-12/P.No. 55/9.11)

9.12 KSRB 9-4.3: Providing Matti/Nandi wood frames of doors, windows,


clerestory windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves (excluding cost of cement
concrete and side clamps), but including cost of materials, labour, HOM of cum 60183.00
machineries complete as per specifications. Specification No. KBS 9.33
(PWD SR 2011-12/P.No. 55/9.12)

9.13 KSRB 9-4.4: Providing Sal wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps), but including cost of materials, labour, HOM of machineries cum 43052.00
complete as per specifications. Specification No. KBS 9.33 (PWD SR
2011-12/P.No. 55/9.13)

9.14 KSRB 9-5.1: Providing and fixing in position fully panelled Teak wood
class -II shutters for doors, styles and rails of 40mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 6356.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 55/9.14)

9.15 KSRB 9-5.2: Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 40mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 3327.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.15)
9.16 KSRB 9-5.3: Providing and fixing in position fully panelled Matti / Nandi
wood shutters for doors, styles and rails of 40mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2894.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.16)

9.17 KSRB 9-6.1: Providing and fixing in position fully panelled Teak wood
class-II shutters for doors, styles and rails of 35mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 5974.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.17)

9.18 KSRB 9-6.2: Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 35mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 3143.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.18)

9.19 KSRB 9-6.3: Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors, styles and rails of 35mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2741.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.19)

9.20 KSRB 9-7.1: Providing and fixing in position fully panelled Teak wood
class-II shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 5592.00
machineries complete as per specifications. (excluding cost of fixtures)
(PWD SR 2011-12/P.No. 56/9.20)

9.21 KSRB 9-7.2: Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 30mm, thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2959.00
machineries complete as per specifications. (excluding cost of fixtures)
(PWD SR 2011-12/P.No. 56/9.21)

9.22 KSRB 9-7.3 : Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2587.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.22)
9.23 KSRB 9-8.1 : Providing and fixing in position fully panelled Teak wood
class-II shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 20mm thick including cost of materials, labour, HOM of Sqm 5171.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.23)

9.24 KSRB 9-8.2 : Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 30mm, thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 20mm thick including cost of materials, labour, HOM of Sqm 2775.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.24)

9.25 KSRB 9-8.3 : Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors, styles and rails of 30mm, thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 20mm thick including cost of materials, labour, HOM of Sqm 1960.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34 (PWD SR 2011-12/P.No. 56/9.25)

9.26 KSRB 9-9.1 : Providing and fixing in position Teak wood class-II half
panelled and half glazed shutters for doors, styles and rails of 40mm, thick
with bottom and lock rails 180mm wide top rail and styles 100mm wide as
per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 5326.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42
(PWD SR 2011-12/P.No. 56/9.26)

9.27 KSRB 9-9.2 : Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 40mm, thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2922.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42
(PWD SR 2011-12/P.No. 56/9.27)

9.28 KSRB 9-10.1: Providing and fixing in position Teak wood class-II half
panelled and half glazed shutters for doors, styles and rails of 35mm, thick
with bottom and lock rails 180mm wide top rail and styles 100mm wide as
per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4944.00
including cost of materials, labour, HOM of machineries complete as per
specifications No. 9.34, 9.42 (excluding cost of fixtures) (PWD SR 2011-
12/P.No. 56/9.28)
9.29 KSRB 9-10.2: Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 35mm, thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2738.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2011-12/P.No. 56/9.29)

9.30 KSRB 9-11.1: Providing and fixing in position Teak wood class-II half
panelled and half glazed shutters for doors, styles and rails of 30mm, thick
with bottom and lock rails 180mm wide top rail and styles 100mm wide as
per drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4485.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2011-12/P.No. 57/9.30)

9.31 KSRB 9-11.2: Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 30mm, thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 2517.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2011-12/P.No. 57/9.31)

9.32 KSRB 9-12.1: Providing and fixing in position Teak wood class-II half
panelled and half shutters for doors, styles and rails of 30mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 20mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4233.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2011-12/P.No. 57/9.32)

9.33 KSRB 9-12.2 : Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 30mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 20mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface
Sqm 2407.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42 (PWD SR 2011-12/P.No. 57/9.33)
9.34 KSRB 9-13.1 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 2604.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.26.4 (PWD SR 2011-12/P.No.
57/9.34)

9.35 KSRB 9-13.2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side and balancing white colour on the
other including cost of materials, labour, HOM of machineries complete as Sqm 2547.00
per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.26.4 (PWD SR 2011-12/P.No. 57/9.35)

9.36 KSRB 9-13.3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior gradeplain particle board including cost of
materials, labour, HOM of machineries complete as per specifications. Sqm 2463.00
(excluding cost of fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR
2011-12/P.No. 57/9.36)

9.37 KSRB 9-14.1 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 2388.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.26.4 (PWD SR 2011-12/P.No.
57/9.37)

9.38 KSRB 9-14.2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side and balancing white colour on the
other including cost of materials, labour, HOM of machineries complete as Sqm 2363.00
per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.26.4 (PWD SR 2011-12/P.No. 57/9.38)
9.39 KSRB 9-14.3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade plain particle board including cost of Sqm 2386.00
materials, labour, HOM of machineries complete as per specifications.
(excluding cost of fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR
2011-12/P.No. 57/9.39)

9.40 KSRB 9-15.1 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 2236.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR 2011-12/P.No.
58/9.40)

9.41 KSRB 9-15.2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side and balancing white colour on the
Sqm 2179.00
other including cost of materials, labour, HOM of machineries complete as
per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.26.3 (PWD SR 2011-12/P.No. 58/9.41)

9.42 KSRB 9-15.3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick, of exterior grade Plain particle board including cost of
materials, labour, HOM of machineries complete as per specifications. Sqm 2095.00
(excluding cost of fixtures) Specification No. KBS 9.34, 9.26.3 (PWD SR
2011-12/P.No. 58/9.42)

9.43 KSRB 9-16.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 35mm. thick, 75mm wide in
two halves with panels of 25mm thick including cost of materials, labour
Charges, HOM of machineries complete as per specifications. (excluding Sqm 7089.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2011-12/P.No.
58/9.43)

9.44 KSRB 9-16.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 35mm. thick, 75mm wide in
two halves with panels of 25mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 3504.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2011-12/P.No.
58/9.44)
9.45 KSRB 9-16.3 : Providing and fixing in position Matti / Nandi wood fully
panelled shutters for windows with styles and rails of 35mm. thick, 75mm
wide in two halves with panels of 25mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 3041.00
(excluding cost of fixtures) Specification No. KBS 9.34. (PWD SR 2011-
12/P.No. 58/9.45)

9.46 KSRB 9-16.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 35mm. thick, 75mm wide in
two halves with panels provided with NUWUD (MDF) of 25mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 2741.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2011-12/P.No. 58/9.46)

9.47 KSRB 9-17.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and styles and rails of 30mm. thick, 75mm
wide in two halves with panels of provided with NUWUD (MDF) of 20mm
thick including cost of materials, labour charges, HOM of machineries
Sqm 6026.00
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, (PWD SR 2011-12/P.No. 58/9.47)

9.48 KSRB 9-17.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 30mm. thick, 75mm wide in
two halves with panels of 20mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 3038.00
cost of fixtures) Specification No. KBS 9.34 (PWD SR 2011-12/P.No.
58/9.48)

9.49 KSRB 9-17.3 : Providing and fixing in position Matti / Nandi wood fully
panelled shutters for windows with styles and rails of 30mm, thick 75mm
wide in two halves with panels of 20mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 2653.00
(excluding cost of fixtures) Specification No. KBS 9.34 (PWD SR 2011-
12/P.No. 58/9.49)

9.50 KSRB 9-17.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 30mm, thick 75mm wide in
two halves with panels provided with NUWUD (MDF) of 18mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 2508.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2011-12/P.No. 59/9.50)

9.51 KSRB 9-18.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 25mm, thick 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 5495.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2011-12/P.No.
59/9.51)
9.52 KSRB 9-18.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 25mm, thick 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, HOM of machineries complete as per specifications. (excluding Sqm 2806.00
cost of fixtures) Specification No. KBS 9.34. (PWD SR 2011-12/P.No.
59/9.52)

9.53 KSRB 9-18.3 : Providing and fixing in position Matti / Nandi wood fully
panelled shutters for windows with styles and rails of 25mm, thick 75mm
wide in two halves with panels of 20mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 2459.00
(excluding cost of fixtures) Specification No. KBS 9.34. (PWD SR 2011-
12/P.No. /9.53)

9.54 KSRB 9-18.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 25mm, thick 75mm wide in
two halves with panels provided with NUWUD (MDF) of 18mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 2219.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2011-12/P.No. 59/9.54)

9.55 KSRB 9-18.5 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 25mm, thick 75mm wide in
two halves with panels provided with NUWUD (MDF) of 12mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 2156.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.26.3 (PWD SR 2011-12/P.No. 59/9.55)

9.56 KSRB 9-19.1 : Providing and fixing in position Teak wood half panelled
shutters at bottom and half glazed at top for window shutters with styles
and rails of 35mm, thick 75mm wide in two halves with panels of 25mm
thick, 3mm thick reeded glass for top parnels fixed with wooden beading Sqm 6069.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 59/9.56)

9.57 KSRB 9-19.2 : Providing and fixing in position Honne wood half panelled
shutters at bottom and half glazed at top for windows shutters with styles
and rails of 35mm, thick 75mm wide in two halves with panels of 25mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 3231.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 59/9.57)
9.58 KSRB 9-19.3 : Providing and fixing in position Matti / Nandi wood half
panelled shutters at bottom and half glazed at top for windows shutters
with styles and rails of 35mm, thick 75mm wide in two halves with panels
of 25mm thick 3mm thick reeded glass for top panels fixed with wooden Sqm 2865.00
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No. 59/9.58)

9.59 KSRB 9-19.4 : Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for windows shutters with Honne
wood styles and rails of 35mm, thick 75mm wide in two halves with panels
filled with NUWUD (MDF) of 18mm thick 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour Sqm 2781.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures) Specification No. KBS 9.34, 9.42, 9.26.3 (PWD SR 2011-
12/P.No.59/9.59)

9.60 KSRB 9-20.1 : Providing and fixing in position Teak wood half paneled
shutters at bottom and half glazed at top for windows shutters with styles
and rails of 30mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 5405.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 PWD SR 2011-12/P.No.60/9.60)

9.61 KSRB 9-20.2 : Providing and fixing in position Honne wood half paneled
shutters at bottom and half glazed at top for windows shutters with styles
and rails of 30mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 2940.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 PWD SR 2011-12/P.No. 60/9.61)

9.62 KSRB 9-20.3 : Providing and fixing in position Mathi / Nandi wood half
paneled shutters at bottom and half glazed at top for windows shutters with
styles and rails of 30mm, thick 75mm wide in two halves with panels of
20mm thick 3mm thick reeded glass for top panels fixed with wooden Sqm 2622.00
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No.60/9.62)

9.63 KSRB 9-20.4 : Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for windows shutters with Honne
wood styles and rails of 30mm, thick 75mm wide in two halves with panels
filled with NUWUD (MDF) of 18mm thick 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour Sqm 2359.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures) Specification No. KBS 9.34, 9.42, 9.26.3 (PWD SR 2011-
12/P.No.60/9.63)
9.64 KSRB 9-21.1 : Providing and fixing in position half panelled shutters at
bottom and half glazed at top for windows shutters with Teak wood styles
and rails of 25mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 4966.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No.60/9.64)

9.65 KSRB 9-21.2 : Providing and fixing in position half panelled shutters at
bottom and half glazed at top for windows shutters with Honne wood styles
and rails of 25mm, thick 75mm wide in two halves with panels of 20mm
thick 3mm thick reeded glass for top panels fixed with wooden beading Sqm 2800.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 60/9.65)

9.66 KSRB 9-21.3 : Providing and fixing in position half panelled shutters at
bottom and half glazed at top for windows shutters with Matti / Nandi wood
styles and rails of 25mm, thick 75mm wide in two halves with panels of
20mm thick 3mm thick reeded glass for top panels fixed with wooden
beading including cost of materials, labour charges, HOM of machineries Sqm 2515.00
complete as per specifications. (excluding cost of fixtures) Specification
No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No. 60/9.66)

9.67 KSRB 9-21.4 : Providing and fixing in position windows half panelled
shutters at bottom and half glazed at top for windows shutters with Honne
wood styles and rails of 25mm, thick 75mm wide in two halves with panels
filled with NUWUD (MDF) of 18mm thick 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour
Sqm 2188.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures) Specification No. KBS 9.34, 9.42, 9.26.3 (PWD SR 2011-
12/P.No. 60/9.67)

9.68 KSRB 9-22.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 35mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 4190.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 60/9.68)

9.69 KSRB 9-22.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 35mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 2311.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 60/9.69)
9.70 KSRB 9-23.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 30mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete
Sqm 3791.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 60/9.70)

9.71 KSRB 9-23.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 30mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 2136.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No.61/9.71)

9.72 KSRB 9-24.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 25mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 3392.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 61/9.72)

9.73 KSRB 9-24.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 25mm, thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 1962.00
as per specifications. (excluding cost of fixtures) Specification No. KBS
9.34, 9.42 (PWD SR 2011-12/P.No. 61/9.73)

9.74 KSRB 9-25.1 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Teak wood styles and rails of
30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 5213.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No. 61/9.74)

9.75 KSRB 9-25.2 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Honne wood styles and rails of
30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 2440.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No. 61/9.75)
9.76 KSRB 9-25.3 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Matti / Nandi wood styles and
rails of 30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm
thick reeded glass fixed with wooden beading of size 10mm wide flushed
to the thickness of the frame including cost of materials, labour charges, Sqm 2566.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No.
61/9.76)

9.77 KSRB 9-26.1 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Teak wood styles and rails of
25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 3045.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No. 61/9.77)

9.78 KSRB 9-26.2 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Honne wood styles and rails of
25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the
thickness of the frame including cost of materials, labour charges, HOM of Sqm 1758.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No. 61/9.78)

9.79 KSRB 9-26.3 : Providing and fixing in position fully glazed shutters for
ventilators side hyng or central pivoted with Matti / Nandi wood styles and
rails of 25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm
thick reeded glass fixed with wooden beading of size 10mm wide flushed
to the thickness of the frame including cost of materials, labour charges, Sqm 1586.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34, 9.42 (PWD SR 2011-12/P.No.
61/9.79)

9.80 KSRB 9-27.1 : Fixing of door frame in an existing opening including


embeding Nos frame in floor and walls after cutting masonry for holdfasts
for embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good
Nos. 778.00
the damagest to walls and floors as required and disposal of the debries
with lead upto 50 m. including cost of materials, labour charges, complete
as per specification (PWD SR 2011-12/P.No. 61/9.80)

9.81 KSRB 9-27.2 : Fixing of windows frame in an existing opening including


embedding frame in floor and walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good
Nos. 528.00
the damagest to walls and floors as required and disposal of the debries
with lead upto 50 m. including cost of materials, labour charges, complete
as per specification (PWD SR 2011-12/P.No. 61/9.81)
9.82 KSRB 9-27.3 : Fixing of ventilator frame in an existing opening including
embedding frame in walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good
the damages to walls and floors as required and disposal of the debries Nos. 411.00
with lead upto 50 m. including cost of materials, labour charges, complete
as per specification (PWD SR 2011-12/P.No. 61/9.82)

9.83 "SOLID PANEL PVC DOOR SHUTTER Providing and fixing 30mm thick
factory made rigid foam panelled Door Shutters made from M.S. tube of 19
gauge thickness, size 19x19mm for styles and 15 x 15mm for top & bottom
rails, covered with heat moulded PVC 'C' channel of 5mm thick sheet & 30
x 50mm wide to form styles & 5mm thick & 75mm wide PVC sheets for top
rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC
sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC
sheet fitted in the M.S. Frame, Sealed to the styles & rails with 5 x 30mm Sqm 1894.00
PVC sheet beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.
(PWD SR 2011-12/P.No. 62/9.83)

9.84 "SOLID PVC DOOR FRAME" Providing and fixing factory made PVC door
frame of size 50 x 47mm with a wall thickness of 5mm, made out of
extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2
No.s of 150mm long brackets of 15 x 15mm M.S. Square tube, the entire
door frame to be reinforced with 19 x19mm M.S. Square tube fo 19 guage. Sqm 315.00
The door frame to be fixed to the wall using M.S. Screws of 65/80mm size
complete as per manufatures specifications & direction of Engineer-in-
charge. (PWD SR 2011-12/P.No. 62/9.84)

9.85 "SOLID PANEL PRELAM PVC DOOR SHUTTER Providing and fixing
30MM thick factory made rigid foam Prelam Panelled Door Shutters made
from M.S. tube of 19 x 19mm, 19 gauge for styles and 15 x 15mm for top
& bottom rails, covered with heat moulded Prelaminated PVC 'C' Channel
of 5mm thick sheet & 30 x 50mm wide to form styles & 5mm thick & 75mm
wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either
side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail &
bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side
fitted in the M.S Frams, Sealed to the styles & rails with PVC Designer
beading on either side & joined together with solvent cement adhesive
etc., Complete as per manufacturers specification & direction of Engineer-
in-charge fixed to frames with 3 nos of 75mm. Aluminium hinges. (PWD
SR 2011-12/P.No. 62/9.85)
9.85.1 "SOLID PANEL PRELAM PVC DOOR SHUTTER Providing and fixing
30MM thick factory made rigid foam with both side Prelam Panelled Door
Shutters made from M.S. tube of 19 x 19mm, 19 gauge for styles and 15 x
15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC 'C' Channel of 5mm thick sheet & 30 x 50mm wide to form styles &
5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail &
bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as
gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet
Sqm 2583.00
Prelaminated on either side fitted in the M.S Frams, Sealed to the styles &
rails with PVC Designer beading on either side & joined together with
solvent cement adhesive etc., Complete as per manufacturers
specification & direction of Engineer-in-charge fixed to frames with 3 nos of
75mm. Aluminium hinges. (PWD SR 2011-12/P.No. 62/9.85.1)

9.85.2 "SOLID PANEL PRELAM PVC DOOR SHUTTER Providing and fixing
30MM thick factory made rigid foam with one side Prelam Panelled Door
Shutters made from M.S. tube of 19 x 19mm, 19 gauge for styles and 15 x
15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC 'C' Channel of 5mm thick sheet & 30 x 50mm wide to form styles &
5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail &
bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as
gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet
Sqm 2504.00
Prelaminated on either side fitted in the M.S Frams, Sealed to the styles &
rails with PVC Designer beading on either side & joined together with
solvent cement adhesive etc., Complete as per manufacturers
specification & direction of Engineer-in-charge fixed to frames with 3 nos of
75mm. Aluminium hinges. (PWD SR 2011-12/P.No. 62/9.85.2)

9.86 "PVC DOOR SHUTTER (Nandi or Equivalent) Supply and fixing of door
shutters made of rigid PVC extruded hollow section (Nandi or equivalent)
of 20mm x 200mm with the wall thickness of 1.0mm +/0.1mm equally
divided into 4No's with tongue and groove locking arrangements. The
shutter frame is made of 58 x 24mm with the wall thickness of 1.5mm +/-
0.15mm section metricut and joined at 4 conrners with 125mm x 225mm
plastic brackets. The shutter shall be horizontally reinforced with 2Nos. of Sqm 1596.00
8mm PVC rods. Teak wood dattoms shall be reinforced inside the door
shutter during the fabrication of the door shutter at those points wherever
the hardware is fixed on to the door shutter. (PWD SR 2011-12/P.No.58-
62/9.86)

9.87 Supply and fixing of door shutters made of rigid PVC extruded hollow
section (Nandi or equivalent) of 20mm x 200mm with the wall thickness of
1.0mm +/0.1mm equally divided into 4No's with tongue and groove locking
arrangements. The shutter frame is made of 30 x 79mm with the wall
thickness of 1.5mm +/-0.15mm section metric cut and joined at 4 conrners
with 125mm x 225mm plastic brackets. The shutter shall be horizontally Sqm 1770.00
reinforced with 2Nos. of 8mm PVC rods. Teak wood dattoms shall be
reinforced inside the door shutter during the fabrication of the door shutter
at those points wherever the hardware is fixed on to the door shutter.
(PWD SR 2011-12/P.No. 63/9.87)
9.88 Supply and fixing of door frame made of hollow extruded PVC Section
(Nandi or equivalent) having dimension of 40 x 57mm with the wall
thickness of 2.0mm +/0.2mm duly reinforced with seasoned wood plank at
the hinges side. The door frame top 2 corners shall be metric cut/weilded. m 216.00
(PWD SR 2011-12/P.No. 63/9.88)

9.89 Supply and fixing of door frame made of hollow extruded PVC Section
(Nandi or equivalent) having dimension of 40 x 46mm with the wall
thickness of 2.0mm +/0.2mm duly reinforced with seasoned wood plank at m 198.00
the hinges side. The door frame top 2 corners shall be metric cut/welded.
(PWD SR 2011-12/P.No. 63/9.89)

9.90 Providing and fixing factory made splendor of solid core single leaf rigid
composite polymer laminated sal wood, door shutter of required thickness,
manufactured out of solid core door conforming to IS 2202 (Part-1) 1991,
laminated with 0.8 mm thick polymer, termite, water resistant and fire
retardant with superior gluing based on vacum lamination technology and
with various pre moulded design on both faces conforming to IS 6307-
1985, using adhesive conforming to IS 4835-1979 and door shutters
tested in conformation is IS 4020-1994. The finish of shutters will be
TEADK/OAK/CEDAR/ROSE WOOD/WALNUT, plain colours
WHITE/VORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot. (PWD SR 2011-
12/P.No. 63/9.90)

9.90.1 Providing and fixing factory made splendor of solid core single leaf rigid
composite polymer laminated sal wood with door shutter 30mm thick of
required thickness, manufactured out of solid core door conforming to IS
2202 (Part-1) 1991, laminated with 0.8 mm thick polymer, termite, water
resistant and fire retardant with superior gluing based on vacum lamination
technology and with various pre moulded design on both faces conforming
to IS 6307-1985, using adhesive conforming to IS 4835-1979 and door Sqm 2900.00
shutters tested in conformation is IS 4020-1994. The finish of shutters will
be TEADK/OAK/CEDAR/ROSE WOOD/WALNUT, plain colours
WHITE/VORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot. (PWD SR 2011-
12/P.No. 63/9.90.1)

9.90.2 Providing and fixing factory made splendor of solid core single leaf rigid
composite polymer laminated sal wood with door shutter 35mm thick of
required thickness, manufactured out of solid core door conforming to IS
2202 (Part-1) 1991, laminated with 0.8 mm thick polymer, termite, water
resistant and fire retardant with superior gluing based on vacum lamination
technology and with various pre moulded design on both faces conforming
to IS 6307-1985, using adhesive conforming to IS 4835-1979 and door Sqm 3300.00
shutters tested in conformation is IS 4020-1994. The finish of shutters will
be TEADK/OAK/CEDAR/ROSE WOOD/WALNUT, plain colours
WHITE/VORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot. (PWD SR 2011-
12/P.No.63/9.90.2)
9.91 Providing and fixing factory made 30mm PVC rigid foam (FOREX) PANEL
DOORS Rajashree made from MS tube of 19 guage, size of 19mm x
19mm and covered with heat moulded PVC 'C' Channel of 5mm thick and
width of 50mm to form styles and rails. The inner panel should be inserted
in between the frame with 5mm thick PVC rigid foam sheet, welded/sealed Sqm 2280.00
to the styles and rails along with 5mm PVC, beeding on all and either
sides. The vertical tubes may be filled with suitable wood material to
further enhance the screw holding capacity (PWD SR 2011-12/P.No.
63/9.91)

9.92 Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a
wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet,
mitre cut at two corners and joined with 2 No.s of 150mm long brackets of
15 x 15mm M.S Square tube. The two vertical door profiles are to be
reinforced with 19x19mm M.S. Square tube of 19 guage, EPDM rubber
gasket weather seal to be provided through out the frame. The door m 336.00
screws through the frame by using PVC fasteners. A minimum of 4 Nos. of
screws to be provided for each vertical member & minimum 2 Nos. for
horizontal member. (PWD SR 2011-12/P.No. 63/9.92)

9.93 Providing and fixing factory made single leaft rigid GRP Sandwich
composite door shutter of 32mm thick, laminated with two GRP skins with
wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and on
layer of 450 gsm E-Glass Chopped strand Mat (CSM) impregnated with
orthopthalic polyster resin. The thickness of the skins shall not be less than
1.5mm. Expanded Polystyrece (EPS) structural foam panel of 29mm
thickness and a density of 20 kg/m3 shall be used as core material.
Wooden reinforcements made of Seasoned Salwood block of cross
section not less than 28mm x 32mm and also necessary salwood
reinforcements for fixing the metal fittings such as tower bolts, aldrops,
handles, etc., shall be provided. A structural adhesive compatible with EPS
foam shall be used for Sqm 2880.00

bonding the core material, the Salwood reinforcement and the skins. The
material and process for manufacturing the door shutters shall confirm to
RV/TIFAC Composites Design centre Standards and specifications and
the door shutters tested in confiramation to IS 4020-1994. The finish of
shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour
using high quality pigments. Exclusing cost of fixtures and inclusive of
supply of shutters to respective work spot. (PWD SR 2011-12/P.No.
64/9.93)

9.94 Providing and fixing factory made single leaf rigid GRP Sandwich
composite door shutter of 40mm thick, laminated with two GRP skins with
wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and
one layer of 450 gsm E-Glass Chopped strand Mat (CSM) impregnated
with orthopthalic polyster resin. The thickness of the skins shall not be less
than 1.5mm. Expanded Polystyrece (EPS) structural foam panel of 37mm
thickness and a density of 20 kg/m3 shall be used as core material.
Wooden reinforcements made of Seasoned Salwood block of cross
section not less than 36mm x 32mm and also necessary salwood
reinforcements for fixing the metal fittings such as tower bolts, aldrops,
handles, etc., shall be provided. A structural adhesive compatible with EPS
foam shall be used for Sqm 3600.00
Sqm 3600.00

bonding the core material, the Salwood reinforcement and the skins. The
material and process for manufacturing the door shutters shall confirm to
RV/TIFAC Composites Design centre Standards and specifications and
the door shutters tested in confiramation to IS 4020-1994. The finish of
shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour
using high quality pigments. Exclusing cost of fixtures and inclusive of
supply of shutters to respective work spot. (PWD SR 2011-12/P.No.
64/9.94)

9.95 Providing and fixing 65mm x 90mm GRP Doorframe fabricated using E-
Glass Chopped Strand Mat (CSM). U.V-stabilized Isopthalic Gelcoat and
Isopthalic resin. The thickness of the GRP skin shall not be less than
2.0mm. The door frame consists of four segments. which are provided with
plug-in-socket arrangement in-situ in the mould. The segments are
plugged in and are joined together by means of screws. The GRP frame
shall be provided with wooden reinforcement of 6 locations fro high screw m 430.00
holding capacity for fixing metallic hold fast and shall be consolidated by
filling with medium density foam/Plaster with fibre reinforcement. Six
numbers of 260 mm x 25mm x 5mm size 'S' shaped M.S. flat hold fast
shall be provided with the frame. (PWD SR 2011-12/P.No. 64/9.95)

9.96 Providing and fixing 65mm x 125mm GRP Doorframe fabricated using E-
Glass Chopped Strand Mat (CSM). U.V-stabilized Isopthalic Gelcoat and
Isopthalic resin. The thickness of the GRP skin shall not be less than
2.0mm. The door frame consists of four segments. which are provided with
plug-in-socket arrangement in-situ in the mould. The segments are
plugged in and are joined together by means of screws. The GRP frame
shall be provided with wooden reinforcement on 6 locations fro high screw
holding capacity for fixing metalling hold fast and shall be consolidated by m 500.00
filling with medium density foam/Plaster of Pairs with fibre reinforcement.
Six numbers of 260 mm x 25mm x 5mm size 'S' shaped M.S. flat hold fast
shall be provided with the frame. (PWD SR 2011-12/P.No. 65/9.96)

9.97 Providing GRP Unbreakable railings available in a wide range of attractive


colours made out of cross section > 70 mm x 64mm of standard lenght 7
feet (approximate 3.6 Kg/m). The material and process for manufacturing
reilings shall confirm to RV-TIFAC composites design centre standards Each 396.00
and specifications. (PWD SR 2011-12/P.No. 65/9.97)
9.98 Providing and fixing RCC door frames factory manufactured, with C.C. 1:1
1/2:3 reinforced with 3 Nos. of 6 mm dia. Main bars and 6mm dia. Stirrups
welded at 30cm C/C, vibrating, curing including cost of steel and
fabrication charges having 3 Nos. of hinges with 20mm x 3mm M.S. flat
welded with required iron roads and flats with drilling and fixing 4 No. of flat
screw nuts each in concrete for fixing hinges and making necessary
provision in concrete for fixing aldorps, tower bolts etc., including cost of m 198.00
one coat of oil based enamel primer, 4 No. of hold fasts, 3 Nos. ISS Iron
oxidised hinges necessary metal screws etc., compelte 60 mm x 100 mm
size-Door frames. (PWD SR 2011-12/P.No. 65/9.98)

9.99 Providing and fixing Mosquito mesh to mesh to windows with 7.5 mm to
1.25 mm thick Honne wood petties includung labour charges etc., Sqm 660.00
complete. (PWD SR 2011-12/P.No. 65/9.99)

9.100 Providing green wood frames for doors, Windows,clerestory windows,


ventilators and other frames, wrought gramed or assembled including
making plaster grooves (excluding cost of cement, concrete and fixing Cum 63000.00
charges) but including cost of materials labour,HOM of machineries
complete. (PWD SR 2011-12/P.No. 65/9.100)

9.101 Providing and fixing 65mmx125mm green wood frames for window
celestory windows, ventilators and other frames, framed or assembled
including making plaster grooves (excluding cost of cement, concrete and
side clamps) including providing and fixing,in position fully glazed window
shutters with 4mm thick plain glass fixed with wooden beading including Sqm 5100.00
cost of materials, labour charges HOM of machineries and fixing in
position etc., complete.(including cost of fixtures).(PWD SR 2011-12/P.No.
65/9.101)

9.102 Providing and fixing require line slope roofing with semi-corrugated PVC
roofing sheets of industrial profile 250/40 in 2.00 mm thick white colour, fire
and heat resistant having width of 1.054 mtrs. Fixed with sell tapping
screws with washers, over the existing purlins, rafters and trusses Sqm 760.00
including cost of materials, labour, complete as per specification. (PWD SR
2011-12/P.No. 65/9.102)

9.103 Providing and fixing teak wood Hand railing to staircase using bulusters of
sections 40mm x 25 mm as per design drawing No. 11863/railings issued
by the Principal Chief Architect and fixing it to the steps using anchor bolts
and necessary adhesive materials and fixing T.W. handrail of section
75x75 mm to bulusters and finishing the same by using colourless polish
etc., complete. The work includes cost of all materials, labour charges for m 7282.00
all items of work. hire charges for welding, cutting and grinding equipment,
and electricity charges, with lead and lift, loading and unloading charges
etc., complete as per drawing and specification. (PWD SR 2011-12/P.No.
66/9.103)

.
10.0 WATER PROOFING
10.1 KSRB 10.2: Providing and laying in position yelahanka tiles of size 250 x
250mm of approved quality and make, over a bed of cement mortar 1:3 an
average thickness 25mm over weather proof course and pointed with
cement mortar 1:3 mix with red oxide including curing cost of materials, Sqm 589.00
labour complete as per specification. Specification No. KBS (PWD
SR2011-12/P.No. 68/10.2)

10.2 KSRB 10.3: Providing and laying integral cement based waterproofing
treatment including preparation of surface as required for treatment of
roofs, balconies, terraces etc., consisting of following application. (a)
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with proprietary water proofing compound conforming to
IS:2645 over the RCC slab after cleaning the surface before treatments.
(b) Laying cement concrete using broken brick bats 25mm to 100mm size
with 50% of cement mortar 1:5 admixed with proprietary water proofing
compound conforming IS : 2645 over 20mm thick layer of cement mortar
1:5 admixed with proprietary water proofing compound to required slope
and treating similarly the adjoining walls upto 300 mm height including
rounding off junctions of walls and slabs. (c) After two days of proper Sqm 642.00
curing, applying a second coat of cement slurry admixed with proprietary
water proofing compound (d) Finishing the surface with 20mm thick
jointless cement mortar of mix 1:4

admixed with proprietary water proofing compound and finally finishing the
surface with trowel and neat cement. slurry and making of 300 x 300 mm
square. (e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test including cost of
materials, labour complete as per specifications. (PWD SR2011-12/P.No.
68/10.40)

10.3 KSRB 10.4: Providing and laying four courses water proofing treatment
with bitumen felt over roof consisting of first and third courses of blown
and / or residual bitumen applied hot at 1.45 kg / sqm of area for each
course second course of roofing felt Type -3 grade-I (heassian based self
finish bitumen felt) and forth and final course of stone grit 6mm and down
size or pea sized gravel spread at 0.06 cum./sqm including preparation of Sqm 304.00
surface but excluding grading complete with bitumen felt (hessian based)
Type - 3 grade -! blown or / and residual bitumen applied hot 1.4 kg/sqm
including cost of materials, labour complete as per specifications. KBS
10.4.3 (PWD SR2011-12/P.No. 68/10.4)

10.4 KSRB 10.5: Providing and laying six courses water proofing treatment with
bitumen felt over roof consisting of first, third and fifth courses of blown
and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of
area for respectively, second and fourth courses of roofing felt Type - 2
grade-I (fibre based self finish bitumen felt) and sixth and final course of Sqm 536.00
stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. /
sqm including preparation of surface, excluding grading but including cost
of materials, labour complete as per specifications. KBS 10.4.3 (PWD
SR2011-12/P.No. 68/10.40)
10.5 Chipping and cleaning, construction joint and slab joint, treatment, grouting
of honey comb by cement with inorganic accelerator for cement, spray of
biological modified Ortho esters and alkaline earth, providing and laying p
patch concrete 1:2:4 for required thickness by clean granite trap jelly
20mm and down size mixed with poly carboxylic sulphonated heutral
cellulose at 100ml/bag and aqueous acrylic silicone emulstion @
125ml/bag and aqueous acrylic silicone emulstion @ 125ml/bag, slurry of
cement and silica sand should be mixed with Cross linked
Acrylic/Stryrene/butadiene based polymer, spraying of silane and silanol
linear copolymer as water broof agent, applying of modified polymers
slurry of soft acrylic esters for extra protection for taking, and filling the
bore wherever concrete, brushing one coat of acrylic copolymer cross
linked formulation on the bore.for roof (PWD SR 2011-12/P.No. 69/10.2)

10.5.1 Chipping and cleaning (Roof), construction joint and slab joint, treatment,
grouting of honey comb by cement with inorganic accelerator for cement,
spray of biological modified Ortho esters and alkaline earth, providing and
laying p patch concrete 1:2:4 for required thickness by clean granite trap
jelly 20mm and down size mixed with poly carboxylic sulphonated heutral
cellulose at 100ml/bag and aqueous acrylic silicone emulstion @
125ml/bag and aqueous acrylic silicone emulstion @ 125ml/bag, slurry of
cement and silica sand should be mixed with Cross linked
Acrylic/Stryrene/butadiene based polymer, spraying of silane and silanol Sqm 834.00
linear copolymer as water broof agent, applying of modified polymers
slurry of soft acrylic esters for extra protection for taking, and filling the
bore wherever concrete, brushing one coat of acrylic copolymer cross
linked formulation on the bore. For Planter box, terrace garden, OHT
and Sump tank, for sunken toilet. (PWD SR 2011-12/P.No. 69/10.5.1)

10.5.2 for planter box, terrace garden, OHT and Sump tank, for sunken toilet.
(PWD SR 2011-12/P.No. 69/10.5.2) Sqm 918.00

10.6 Providing and fixing food grade epoxy painting to over head tank and
sump tank after cleaning and drying including pumping and bailing out of
water, including cost of all materials, labour lead lifts etc., complete of Sqm 90.00
water, including cost of all materials labour lead and lifts etc., complete
(PWD SR 2011-12/P.No. 69/10.6)

10.7 Cleaning RCC sump tanks and RCC overhead tanks with mechanical
dewatering including removal of sludge, mud,dirt,algea etc and cleaning
the wall surface of tanks using high pressure jet, vacuum cleanuing and
spraying anti bacterial treatment to the wall and ceiling surfaces and UV
treatment, including removing of sludge etc., using suitable coconut
L 0.20
broomstick, squesers/wipers/rubber brushes, coir brushes, plastic buckets,
mugs, dewatering using motor with portal arrangement, hose pipe etc.,
complete including including all safely measures. (PWD SR 2011-12/P.No.
69/10.7)
DRAINAGE WORK
11.1 KSRB 12-1.1 : Providing and laying in position to required level or slope
100mm internal diameter salt glazed stoneware pipes grade A and
jointing with stiff mixture of cement mortar in proportion of 1:1, testing of
pipes and joints, including cost of materials, labour charges complete as m 204.00
per specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.1)

11.2 KSRB 12-1.2 : Providing and laying in position to required level or slope
150mm internal diameter salt glazed stoneware pipes grade A and
jointing with stiff mixture of cement mortar in proportion of 1:1, testing of
pipes and joints, including cost of materials, labour charges complete as m 319.00
per specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.2)

11.3 KSRB 12-1.3 : Providing and laying in position to required level or slope
200mm internal diameter salt glazed stoneware pipes grade A and
jointing with stiff mixture of cement mortar in proportion of 1:1, testing of
pipes and joints, including cost of materials, labour charges complete as
m 437.00
per specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.3)

11.4 KSRB 12-1.4 : Providing and laying in position to required level or slope
230mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 476.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.4)

11.5 KSRB 12-1.5 : Providing and laying in position to required level or slope
250mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 513.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.5)

11.6 KSRB 12-1.6 : Providing and laying in position to required level or slope
300mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 567.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.6)

11.7 KSRB 12-1.7 : Providing and laying in position to required level or slope
350mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 604.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.7)
11.8 KSRB 12-1.8 : Providing and laying in position to required level or slope
400mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 656.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.8)

11.9 KSRB 12-1.9 : Providing and laying in position to required level or slope
450mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints, including cost of materials, labour charges complete as per m 768.00
specifications. Specification No. KBS 12.2.5/12.7 (PWD SR2011-
12/P.No.71/11.9)

11.10 KSRB 12-2.1 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 100 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 167.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.10)

11.11 KSRB 12-2.2 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 150 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 281.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.11)

11.12 KSRB 12-2.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 200 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 312.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.12)

11.13 KSRB 12-2.4 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 230 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 337.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.13)
11.14 KSRB 12-2.5 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 250 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 351.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.14)

11.15 KSRB 12-2.6 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 300 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 400.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.15)

11.16 KSRB 12-2.7 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 350 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 449.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.16)

11.17 KSRB 12-2.8 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 400 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 498.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.17)

11.18 KSRB 12-2.9 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite metal,
machine mixed concrete laid in layers not exceeding 15 cms thick, well
compacted, for 450 mm internal diameter stoneware pipes including cost
of materials, labour charges, HOM of machinery, curing complete as per m 544.00
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.71/11.18)

11.19 KSRB 12-3.1 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 100mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 246.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.71/11.19)
11.20 KSRB 12-3.2 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 150mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 398.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.20)

11.21 KSRB 12-3.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 200mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 469.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.21)

11.22 KSRB 12-3.4 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 230mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 540.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.22)

11.23 KSRB 12-3.5 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 250mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 547.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.23)

11.24 KSRB 12-3.6 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 300mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 632.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.24)

11.25 KSRB 12-3.7 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 350mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 722.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.25)
11.26 KSRB 12-3.8 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 400mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 812.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.26)

11.27 KSRB 12-3.9 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for haunching of 450mm internal diameter stoneware pipes,
concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of m 902.00
machinery, curing complete as per specifications. Specification No. KBS
4.1/4.2 (PWD SR2011-12/P.No.72/11.27)

11.28 KSRB 12-4.1 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 100mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 523.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.28)

11.29 KSRB 12-4.2 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 150mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 636.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.29)

11.30 KSRB 12-4.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 200mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 742.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.30)

11.31 KSRB 12-4.4 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 230mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 810.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.31)

11.32 KSRB 12-4.5 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 250mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 860.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.32)
11.33 KSRB 12-4.6 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 300mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 979.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.33)

11.34 KSRB 12-4.7 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 350mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 1116.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.34)

11.35 KSRB 12-4.8 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 400mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 1249.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.35)

11.36 KSRB 12-4.9 : Providing and laying in position plain cement concrete of
mix 1:4:8 (as per design) using 40mm and down size graded granite/ trap
metal, for surrounded encasing 450mm internal diameter stoneware pipes,
concrete machine mixed well compacted, including cost of materials,
m 1376.00
labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1/4.2 (PWD SR2011-
12/P.No.72/11.36)

11.37 KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91m
internal dia at bottom 0.91m deep and 0.56m dia at top with table moulded
non - modular bricks of 50 class designation 50 in cement mortar 1:4,
inside cement plastered 12 mm thick with cement mortar 1:3, finished with
a floating coat of neat cement, foundation concrete 1:3:6 mix using 40mm
and downsize granite metal and making necessary channel in cement
concrete 1:2:4 mix with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS : 12592,
total weight cover and frame to be not less than 182 kg, fixed in cement Nos. 9897.00
concrete 1:2:4, 20mm and downsize broken granite metal, providing and
removing centering, shuttering including cost of materials, labour charges,
HOM of machineries complete as per specification. (Excavation, footrests
and 12mm thick cement plaster on the external surface shall be paid
seperately) Specification No. KBS 12.4 (PWD SR 2011-
12/P.No.72/11.37)
11.38 KSRB 12-5.2 : Constructing brick masonry circular type manhole 0.91m
internal dia at bottom 1.67m deep and 0.56m dia at top with table
moulded non - modular bricks of class designation 50 in cement mortar
1:4, inside cement plastered 12 mm thick with cement mortar 1:3, finish
with a floating coat of neat cement, foundation concrete 1:3:6 mix using
40mm and downsize granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm and downsize granite metal finished
with a floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming IS :
12592, total weight cover and frame to be not less than 182 kg, fixed in Nos. 15151.00
cement concrete 1:2:4, 20mm and downsize broken granite metal,
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2011-12/P.No.73/11.38)

11.39 KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22m
internal dia at bottom 1.68m deep and 0.56m dia at top with table moulded
non - modular bricks of class designation 50 in cement mortar 1:4, inside
cement plastered 12 mm thick with cement mortar 1:3, finished with a
floating coat of neat cement, foundation concrete 1:3:6 mix using 40mm
and downsize granite metal and making necessary channel in cement
concrete 1:2:4 mix with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS : 12592,
total weight length of cover and frame to be not less than 182 kg, fixed in
cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 18718.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2011-12/P.No.73/11.39)
11.40 KSRB 12-5.4 : Constructing brick masonry circular type manhole 1.22m
internal dia at bottom 2.29m deep and 0.56m dia at top with table moulded
and non - modular bricks of class designation 50 in cement mortar 1:4,
inside cement plastered 12 mm thick with cement mortar 1:3, finished with
a floating coat of neat cement, foundation concrete 1:3:6 mix using 40mm
and downsize granite metal and making necessary channel in cement
concrete 1:2:4 mix with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS : 12592,
total weight length of cover and frame to be not less than 182 kg, fixed in
cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 22371.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2011-12/P.No.72/11.40)

11.41 KSRB 12-5.5 : Constructing brick masonry circular type manhole 1.52m
internal dia at bottom 2.30m deep and 0.56m dia at top with table
moulded and non - modular bricks of class designation 50 in cement
mortar 1:4, inside cement plastered 12 mm thick with cement mortar 1:3,
finished with a floating coat of neat cement, foundation concrete 1:3:6 mix
using 40mm and downsize granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm and downsize granite metal finished
with a floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming IS :
12592, total weight length of cover and frame to be not less than 182 kg,
fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 30511.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2011-12/P.No.73/11.41)
11.42 KSRB 12-5.6 : Constructing brick masonry circular type manhole 1.52m
internal dia at bottom4.18m deep and 0.56m dia at top with table
moulded and non - modular bricks of class designation 50 in cement
mortar 1:4, inside cement plastered 12 mm thick with cement mortar 1:3,
finished with a floating coat of neat cement, foundation concrete 1:3:6 mix
using 40mm and downsize granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm and downsize granite metal finished
with a floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming IS :
12592, total weight length of cover and frame to be not less than 182 kg,
fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, Nos. 57466.00
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of machineries complete as per specification.
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD SR
2011-12/P.No.73/11.42)

11.43 KSRB 12-5.3 : Constructing circular type manhole 1500mm internal dia
at bottom, 525mm diat at top in brick masonry with 1:5, cement mortar,
cement plaster 1:3 finish with a floating coat of neat cement, RCC 1:2:4
top slab using 20mm and down size granite metal, foundation concrete
1:4:8 using 40mm and down size granite metal and making channels in
cement concrete 1:2:4 mix using 20mm and down size granite metal,
neatly finished curing, fixing CI cover complete including of materials, Nos. 31010.00
labour charges, HOM of mechineries complete as per specifications
(Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately) Specification No. KBS 12.4 (PWD
SR2011-12/P.No.72/11.43)

11.44 KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole
with 1:3:6 cement concrete block of 20x20x10 cms, using 20mm and down
size metal of size including cost of materials, labour charges curing Nos. 188.00
complete as per specifications. Specification No. KBS 12.4.6 (PWD
SR2011-12/P.No.74/11.44)

11.45 KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole
with 1:3:6 cement concrete block of 20x20x10 cms, using 20mm and down
size metal of size including cost of materials, labour charges curing Nos. 190.00
complete as per specifications. Specification No. KBS 12.4.6 (PWD
SR2011-12/P.No.74/11.45)

11.46 KSRB 12-6.3 : Providing cast iron footrest and fixing in manhole with 1:3:6
cement concrete block of 20x20x10 cms, using 20mm and down size
metal of size including cost of materials, labour charges curing complete Nos. 207.00
as per specifications. Specification No. KBS 12.4.6 (PWD SR2011-
12/P.No.74/11.46)
11.47 KSRB 12-7.1 : Making connection of drain or sewer line of size 100 to
230mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3,
finished with a floating coat of neat cement, and making necessary Nos. 1236.00
channels for the drain, including cost of materials, labour charges, curing
complete as per specifications. (PWD SR2011-12/P.No.74/11.47)

11.48 KSRB 12-7.2 : Making connection of drain or sewer line of size 250 to
300mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3,
finished with a floating coat of neat cement, and making necessary Nos. 1624.00
channels for the drain, including cost of materials, labour charges, curing
complete as per specifications. (PWD SR2011-12/P.No.74/11.48)

11.49 KSRB 12-7.3 : Making connection of drain or sewer line of size 350 to
450mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3,
finished with a floating coat of neat cement, and making necessary Nos. 2145.00
channels for the drain, including cost of materials, labour charges, curing
complete as per specifications. (PWD SR2011-12/P.No.74/11.49)

11.50 50 KSRB 12-8.1 : Constructing brick masonry inspection chamber


455x610 mm, and 450mm depth, ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 455x61 Omm internal
dimensions, total weight of cover with frame to be not less than 38 kg
( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with
cement concrete M 15 with 20mm and downsize granite metal, foundation
concrete M 5 with 40mm and downsize granite metal inside plastering Nos. 5125.00
12mm thick with cement mortar 1:3, finish smooth with a floating coat of
cement on walls and bed concrete complete as per standard design
including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS (PWD SR2011-12/P.No.74/11.50)

11.50.1 KSRB 12-8.1 : Constructing brick masonry inspection chamber 600 x


600mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement
mortar 1:5, C.I cover with frame (light duty) 600 x 600mm (PWD SR2011- Nos. 6640.00
12 P.No.74/11.50.1)
11.50.2 50 KSRB 12-8.1 : Constructing brick masonry inspection chamber
455x610 mm, and 450mm depth, ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 455x61 Omm internal
dimensions, total weight of cover with frame to be not less than 38 kg
( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with
cement concrete M 15 with 20mm and downsize granite metal, foundation
concrete M 5 with 40mm and downsize granite metal inside plastering Nos. 3730.00
12mm thick with cement mortar 1:3, finish smooth with a floating coat of
cement on walls and bed concrete complete as per standard design
including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS (PWD SR2011-12 P.No.74/11.50.2)

11.50.3 KSRB 12-8.1 : Constructing brick masonry inspection chamber 450 X


300mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement Nos 2490.00
mortar 1:5, C.I cover with frame (light duty) 450 X 300mm (PWD SR2011-
12/ P.No.75/11.50.3)

11.50.4 KSRB 12-8.1 : Constructing brick masonry inspection chamber 230 x


150mm, and 450mm depth, (clear inside dimension) for single pipeline,
using table moulded non-modular bricks of class designation 50 in cement Nos 635.00
mortar 1:5, C.I cover with frame (light duty) 230 x 150mm (PWD SR2011-
12 P.No.75/11.50.4)

11.51 KSRB 12-8.1.1 : Extra for item no. KSRB 12-8.1 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof
including cost of materials, labour charges, curing complete as per Each 514.00
specifications. (PWD SR2011-12/P.No.75/11.51)

11.52 KSRB 12-8.2 : Constructing brick masonry inspection chamber


500x700mm, and 450mm depth, (clear inside dimension) for pipeline, with
one or two inlets, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I. cover with frame (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not
less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C
top slab with cement concrete 1:2:4 mix 20mm and down size granite
metal, foundation concrete 1:5:10 with 40mm and downsize granite metal Each 5785.00
inside plastering 12mm thick with cement mortar 1:3, finished smooth with
a floating coat of cement on walls and bed concrete complete as per
standard design including cost of materials, labour charges curing
complete as per specifications. (PWD SR2011-12/P.No.75/11.52)

11.53 KSRB 12-8.2.1 : Extra for item no. KSRB 12-8.2 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof Each 569.00
including cost of materials, labour charges, curing complete as per
specifications. (PWD SR2011-12/P.No.75/11.53)
11.54 KSRB 12-8.3: Constructing brick masonry inspection chamber
600x850mm, and 450mm depth, (clear inside dimension) for pipeline, with
three or more inlets, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I. cover with frame (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not
less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C
top slab with cement concrete 1:2:4 mix 20mm and down size granite
metal, foundation concrete 1:5:10 with 40mm and downsize granite metal Each 6555.00
inside plastering 12mm thick with cement mortar 1:3, finished smooth with
a floating coat of cement on walls and bed concrete complete as per
standard design including cost of materials, labour charges curing
complete as per specifications. (PWD SR2011-12/P.No.75/11.54)

11.55 KSRB 12-8.3.1 : Extra for item no. KSRB 12-8.3 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof
including cost of materials, labour charges, curing complete as per Each 659.00
specifications. (PWD SR2011-12/P.No.76/11.55)
SANITARY WORK
12.1 KSRB 11-1 : Providing and fixing white vitreous china clay, water closet
Indian type (Squatting pan) of size 580mm with footrests, 100mm S or P
trap, 10 litre low lavel, PVC flushing cistern (all are approved make) with
fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps,
overflow arrangements with specials and 25mm mosquito proof coupling of
approved design, painting of fittings and brackets, cutting and making pan 2675.00
good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. Specification No. KBS 11 (PWD
SR2011-12/P.No.78/12.1)

12.2 KSRB 11-2 : Providing and fixing white vitreous china clay, water closet
Orissa patten of size 580 x 440mm with integral type footrests, 100mm S
or P trap, 10 litre low lavel, PVC flushing cistern (all are approved make)
with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and
clamps, overflow arrangements with specials and 25mm mosquito proof pan 3242.00
coupling of approved design, painting of fittings and brackets, cutting and
making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications. Specification No. KBS
11 (PWD SR2011-12/P.No.78/12.2)

12.3 KSRB 11-3 : Providing and fixing white vitreous china clay, water closet
Indian type (Squatting pan) of size 580mm with footrests, 100mm S or P
trap, (approved make) cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per pan 929.00
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.78/12.3)

12.4 KSRB 11-4 : Providing and fixing white vitreous china clay, water closet
Orissa pattern of size 580 x 440mm with Integral type footrests, 100mm S
or P trap, (approved make) cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per pan 1496.00
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.78/12.4)

12.5 KSRB 11-5 : Providing and fixing white vitreous china clay, water closet
European type(Pedestal type) with block solid plastic seat and lid, C.P.
brass hinges, rubber buffers. 10 litre low level, P.V.C. flushing cistern (all
are approved make) with fittings, C.I./ M.S brackets, 40mm diameter flush
bend with fittings and clamps, overflow arrangements with special and
25mm mosquito proof coupling of approved design, painting of fittings and Each 3934.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11. (PWD SR2011-12/P.No.78/12.5)
12.6 KSRB 11-6 : Providing and fixing white vitreous china clay, water closet
European type (Pedestal type) with block solid plastic seat and lid, C.P.
brass hinges, rubber buffers. 10 litre white glazed / vitreous china clay low
level, flushing cistern (all are approved make) with fittings, C.I./ M.S
brackets, 40mm diameter flush bend with fittings and clamps, overflow
arrangements with specials and 25mm mosquito proof coupling of
approved design, painting of fittings and brackets, cutting and making Each 3813.00
good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. Specification No. KBS 11. (PWD
SR2011-12/P.No.78/12.6)

12.7 KSRB 11-7.1 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430x260x350mm with 5 litres PVC automatic
flushing cistern, C.I./ M.S brackets, standard flush pipe and C.P.
brass spreaders with brass unions and G.I. clamps complete painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2337.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11. (PWD SR2011-12/P.No.79/12.7)

12.8 KSRB 11-7.2 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430 x 260x350mm in the range of two 7.5 litre
P.V.C. with automatic flushing cistern, C.I/M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps painting
of fittings and brackets, cutting and making good the wall and floor Unit 2947.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.79/12.8)

12.9 KSRB 11-7.3 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430 x 260x350mm in the range of three with
7.5 litre P.V.C. with automatic flushing cistern, C.I/M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps painting of fittings and brackets, cutting and making good the wall Unit 3970.00
and floor wherever required, including cost of materials, labour complete
as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.79/12.9)

12.10 KSRB 11-7.4 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430 x 260x350mm in the range of four with 10
litre P.V.C. automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps painting
of fittings and brackets, cutting and making good the wall and floor Unit 4761.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.79/12.10)
12.11 KSRB 11-8.1 : Providing and fixing white vitreous china clay, well corner
type, lipped front urinal basin of size 340 x 410 x 265mm with 5 litre
P.V.C. automatic flushing cistern, C.I / M.S brackets, standard flush pipe
and C.P. brass spreaders with brass unions and G.I. clamps painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2275.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.79/12.11)

12.12 KSRB 11-8.2 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340 x 410 x 265mm with in the range
of two with 7.5 litre P.V.C. automatic flushing cistern, C.I / M.S
brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps painting of fittings and brackets, cutting and making good
Unit 2829.00
the wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.80/12.12)

12.13 KSRB 11-8.3 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340 x 410 x 265mm with in the range
of three with 7.5 litre P.V.C. automatic flushing cistern, C.I / M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps painting of fittings and brackets, cutting and making good the wall
and floor wherever required, including cost of materials, labour complete Unit 3333.00
as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.80/12.13)

12.14 KSRB 11-8.4 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340 x 410 x 265mm with in the range
of four with 10 litre P.V.C. automatic flushing cistern, C.I / M.S
brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps painting of fittings and brackets, cutting and making good
the wall and floor wherever required, including cost of materials, labour 3900.00
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.80/12.14)

12.15 KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm with 5 litres P.V.C.
automatic flushing cistern, C.I / M.S brackets, standard flush pipe and
C.P. brass spreaders with brass unions and G.I. clamps C.I. dtrap with
outlet grating and other couplings in C.P. brass, painting of fittings and
brackets, cutting and making good the wall and floor wherever required, Unit 4074.00
including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.80/12.15)
12.16 KSRB 11-9.2 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm in the range of two with
7.5 litres P.V.C. automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps,
C.I. trap with outlet grating and other couplings in C.P. brass, painting of Unit 6539.00
fittings and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.80/12.16)

12.17 KSRB 11-9.3 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm in the range of three
with 10 litres P.V.C. automatic flushing cistern, C.I / M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps, C.I. trap with outlet grating and other couplings in C.P. brass,
painting of fittings and brackets, cutting and making good the wall and floor Unit 9017.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.80/12.17)

12.18 KSRB 11-9.4 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580 x 380 x 350mm in the range of four with
10 litres P.V.C. automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps,
C.I. trap with outlet grating and other couplings in C.P. brass, painting of
Unit 11433.00
fittings and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.81/12.18)

12.19 KSRB 11-10.1 : Providing and fixing white vitreous china clay, squatting
plate with 5 litre, P.V.C. automatic flushing cistern including brass
coupling C.I / M.S brackets, G.I. flush pipe of standard size and C.P.
brass spreaders painting of fittings and brackets, cutting and making good
the wall and floor wherever required, including cost of mateirals, labour Unit 2678.00
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.81/12.19)

12.20 KSRB 11-10.2 : Providing and fixing white vitreous china clay, squatting
plate in the range of two single squatting plate with 7.5 litre P.V.C.
automatic flushing cistern including brass coupling C.I. / M.S. brackets,
G.I. flush pipe of standard size and C.P. brass spreaders painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 3860.00
required, including cost of mateirals, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.81/12.20)
12.21 KSRB 11-10.3 : Providing and fixing white vitreous china clay, squatting
plate in the range of three single squatting plates with 10 litre P.V.C.
automatic flushing cistern including brass coupling C.I. / M.S. brackets,
G.I. flush pipe of standard size and C.P. brass spreaders painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 5054.00
required, including cost of mateirals, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.81/12.21)

12.22 KSRB 11-10.4 : Providing and fixing white vitreous china clay, squatting
plate in the range of four single squatting plates with one number 15
litre P.V.C. automatic flushing cistem including brass coupling C.I. /
M.S. brackets, G.I. flush pipe of standard size and C.P. brass spreaders
painting of fittings and brackets, cutting and making good the wall and floor Unit 6248.00
wherever required, including cost of mateirals, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.81/12.22)

12.23 KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back
wash basin size 630 x 450mm with a pair of 15mm C.P. brass pillar
taps with C.I. / M.S brackets, 32mm C.P. brass waste of standard
pattern, painting of fittings and brackets, cutting and making good the wall Unit 2723.00
and floor wherever required, including cost of materials, labour complete
as per specifications. Specification No. KBS 11 (PWD SR201-
12/P.No.81/12.23)

12.24 KSRB 11-11.2 : Providing and fixing white vitreous china clay, flat back
wash basin size 630 x 450mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 2130.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.24)

12.25 KSRB 11-11.3 : Providing and fixing white vitreous china clay, flat back
wash basin size 550 x 400mm with a pair of 15mm C.P. brass pillar
taps with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per Unit 2597.00
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.25)

12.26 KSRB 11-11.4 : Providing and fixing white vitreous china clay, flat back
wash basin size 550 x 400mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 2004.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.26)
12.27 KSRB 11-11.5 : Providing and fixing white vitreous china clay, flat back
wash basin size 450 x 300mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1878.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.27)

12.28 KSRB 11-11.6 : Providing and fixing white vitreous china clay, angle back
wash basin size 600 x 480mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 2130.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.28)

12.29 KSRB 11-11.6 : Providing and fixing white vitreous china clay, angle back
wash basin size 400 x 400mm with a single 15mm C.P. brass pillar taps
with C.I. / M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall and floor Unit 1940.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.29)

12.30 KSRB 11-11.8 : Providing and fixing white vitreous china clay, surgeon
type wash basin size 660 x 460mm with a pair of 15mm C.P. brass
pillar taps with pair of elbow operated levers, C.I. / M.S brackets,
32mm C.P. brass waste of standard pattern, painting of fittings and
brackets, cutting and making good the wall and floor wherever required, Unit 3530.00
including cost of materials, labour complete as per specifications.
Specification No. KBS 11 (PWD SR2011-12/P.No.82/12.30)

12.31 KSRB 11-11.9 : Providing and fixing white vitreous china clay, surgeon
type wash basin size 660 x 460mm with single 15mm C.P. brass pillar taps
with single elbow operated levers, C.I. / M.S brackets, 32mm C.P. brass
waste of standard pattern, painting of fittings and brackets, cutting and
making good the wall and floor wherever required, including cost of Unit 3001.00
materials, labour complete as per specifications. Specification No. KBS 11
(PWD SR2011-12/P.No.83/12.31)

12.32 KSRB 11-12.1 : Providing and fixing kitchen sink of white glazed fire clay
of size 600 x 450 x 250mm with M.S. / C.I. brackets, C.P. brass chain with
rubber plug, 32mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the
Unit 2554.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.83/12.32)
12.33 KSRB 11-12.2 : Providing and fixing kitchen sink of white glazed fire clay
of size 750 x 450 x 250mm with M.S. / C.I. brackets, C.P. brass chain with
rubber plug, 32mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the
Unit 2912.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.83/12.33)

12.34 KSRB 11-13.1 : Providing and fixing laboratory sink of white glazed fire
clay of size 600 x 450 x 200mm with M.S. / C.I. brackets, C.P. brass
chain with rubber plug, 32mm C.P. brass waste, tap with union, brass stop
cock complete, painting of fittings and brackets, cutting and making good
Unit 2534.00
the wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.83/12.34)

12.35 KSRB 11-13.2 : Providing and fixing laboratory sink of white glazed fire
clay of size 450 x 300 x 150mm with M.S. / C.I. brackets, C.P. brass chain
with rubber plug, 32mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the
Unit 2282.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD SR2011-
12/P.No.83/12.35)

12.36 KSRB 11-14.1 : Providing and fixing stainless steel kitchen sink
conforming to IS 13983:1994 of size 500x1575mm bowl depth 220mm,
with one bowl and two drain board, M.S. / C.I. brackets, stainless steel
plug 40mm, painting of fittings and brackets, cutting and making good the Unit 18312.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. (PWD SR2011-12/P.No.83/12.36)

12.37 KSRB 11-14.2 : Providing and fixing stainless steel kitchen sink of size
500x1000mm bowl depth 200mm, with single bowl drain board, M.S. /
C.I. brackets, stainless steel plug 40mm, painting of fittings and brackets,
cutting and making good the wall and floor wherever required, including Unit 8702.00
cost of materials, labour complete as per specifications. (PWD SR2011-
12/P.No.83/12.37)

12.38 KSRB 11-14.3 : Providing and fixing stainless steel kitchen sink of size
400x470mm bowl depth 180mm, with drain board, M.S. / C.I. brackets,
stainless steel plug 40mm, painting of fittings and brackets, cutting and
making good the wall and floor wherever required, including cost of Unit 4834.00
materials, labour complete as per specifications. (PWD SR2011-
12/P.No.84/12.38)

12.39 KSRB 11-15.1 : Providing and fixing 600 x 450mm bevel Lead edge mirror
of superior glass with 6mm hard board backing and fixed to wooden cleats
with C.P. screws, washers, including cost of materials, labour complete as Unit 1017.00
per specifications. (PWD SR2011-12/P.No.84/12.39)
12.40 KSRB 11-15.2 : Providing and fixing 450 mm dia circular shape mirror
with plastic moulded frame of approved make and shade with 6mm thick
hard board backing including cost of materials, labour complete as per Unit 612.00
specifications. (PWD SR2011-12/P.No.84/12.40)

12.41 KSRB 11-15.3 : Providing and fixing 453x357 mm dia rectangular shape
mirror with plastic moulded frame of approved make and shade with 6mm
thick hard board backing including cost of materials, labour complete as Unit 878.00
per specifications. (PWD SR2011-12/P.No.84/12.41)

12.42 KSRB 11-15.4 : Providing and fixing 450x915 mm dia oval shape mirror
with plastic moulded frame of approved make and shade with 6mm thick
hard board backing including cost of materials, labour complete as per Unit 631.00
specifications. (PWD SR2011-12/P.No.84/12.42)

12.43 KSRB 11-15.5 : Providing and fixing 1500x450 mm dia rectangular


shape mirror with plastic moulded frame of approved make and shade
with 6mm thick hard board backing including cost of materials, labour Unit 1208.00
complete as per specifications. (PWD SR2011-12/P.No.84/12.43)

12.44 KSRB 11-16 : Providing and fixing 600x120 mm glass shelf supported on
alluminium angle frame with C.P. brass brackets, guard rail fixed to
wooden cleats with C.P. brass screws and washers including cost of Unit 1052.00
materials, labour complete as per specifications. (PWD SR2011-
12/P.No.84/12.44)

12.45 KSRB 11-17.1 : Providing and fixing C.P. brass towel rail 740mm lenght,
20mm dia with C.P. brackets, fixed to wooden cleats with C.P. brass
screws including cost of materials, labour complete as per specifications. Unit 728.00
(PWD SR2011-12/P.No.84/12.45)

12.46 KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600mm lenght,
20mm dia with C.P. brackets, fixed to wooden cleats with C.P. brass
screws including cost of materials, labour complete as per specifications. Unit 667.00
(PWD SR2011-12/P.No.84/12.46)

12.47 KSRB 11-18.1.1 : Providing and fixing sand cast iron soil waste and vent
pipes 100 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour testing complete as per m 589.00
specifications. KBS 11-1.10 (PWD SR2011-12/P.No.84/12.47)

12.48 KSRB 11-18.1.2 : Providing and fixing sand cast iron soil waste and vent
pipes 75 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour testing complete as per m 511.00
specifications. KBS 11-1.10 (PWD SR2011-12/P.No.84/12.48)
12.49 KSRB 11-18.1.3 : Providing and fixing sand cast iron soil waste and vent
pipes 50 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour testing complete as per m 269.00
specifications. KBS 11-1.10 (PWD SR2011-12/P.No.85/12.49)

12.50 KSRB 11-18.2.1 : Providing and fixing sand cast iron soil waste bends
100 mm dia with access door, insertion of rubber washers 3mm thick
bolts and nut, with spun yarn soaked in cement slurry and cement mortar Each 426.00
1:2 including cost of materials, labour, testing complete as per
specifications. (PWD SR2011-12/P.No.85/12.50)

12.51 KSRB 11-18.2.2 : Providing and fixing sand cast iron soil waste bends
75 mm dia with access door, insertion of rubber washers 3mm thick bolts
and nut, with spun yarn soaked in cement slurry and cement mortar 1:2 Each 354.00
including cost of materials, labour, testing complete as per specifications.
(PWD SR2011-12/P.No.85/12.51)

12.52 KSRB 11-18.2.3 : Providing and fixing sand cast iron soil waste bends
50 mm dia with access door, insertion of rubber washers 3mm thick bolts
and nut, with spun yarn soaked in cement slurry and cement mortar 1:2 Each 328.00
including cost of materials, labour, testing complete as per specifications.
(PWD SR2011-12/P.No.85/12.52)

12.53 KSRB 11-18.3.1 : Providing and fixing sand cast iron soil waste plain
bend 100 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per Each 388.00
specifications. KBS 11-1.10 (PWD SR2011-12/P.No.85/12.53)

12.54 KSRB 11-18.3.2 : Providing and fixing sand cast iron soil waste plain
bend 75 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per Each 303.00
specifications. KBS 11-1.10 (PWD SR2011-12/P.No.85/12.54)

12.55 KSRB 11-18.3.3 : Providing and fixing sand cast iron soil waste plain
bend 50 mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per Each 233.00
specifications. KBS 11-1.10 (PWD SR2011-12/P.No.85/12.55)

12.56 KSRB 11-18.4.1 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 100x100x100x100mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 770.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.85/12.56)

12.57 KSRB 11-18.4.2 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 75x75x75x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 556.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.85/12.57)
12.58 KSRB 11-18.4.3 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 50x50x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 548.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.86/12.58)

12.59 KSRB 11-18.5.1 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 100x100x100x100mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 667.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.86/12.59)

12.60 KSRB 11-18.5.2 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 75x75x75mm, insertion
of rubber washers 3mm thick bolts and nuts, including cost of materials, Each 500.00
labour, testing complete as per specifications. KBS 11-1.10 (PWD
SR2011-12/P.No.86/12.60)

12.61 KSRB 11-18.5.3 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 50x50x50mm, insertion
of rubber washers 3mm thick bolts and nuts, including cost of materials, Each 400.00
labour, testing complete as per specifications. KBS 11-1.10 (PWD
SR2011-12/P.No.86/12.61)

12.62 KSRB 11-18.6.1 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 100x100x75x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 843.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.86/12.62)

12.63 KSRB 11-18.6.2 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 100x100x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 814.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.86/12.63)

12.64 KSRB 11-18.6.3 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 75x75x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 341.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.86/12.64)

12.65 KSRB 11-18.7.1 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 100x100x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 669.00
materials, labour, testing complete as per specifications. KBS 11-1.10
(PWD SR2011-12/P.No.86/12.65)

12.66 KSRB 11-18.7.2 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 100x100x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 646.00
materials, labour, testing complete as per specifications. Specification No.
KBS 11-1.10 (PWD SR2011-12/P.No.86/12.66)
12.67 KSRB 11-18.7.3 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 75x75x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 403.00
materials, labour, testing complete as per specifications. Specification No.
KBS 11-1.10 (PWD SR2011-12/P.No.87/12.67)

12.68 KSRB 11-18.8.1 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 100x100x100x100mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 721.00
KBS 11-1.10 (PWD SR2011-12/P.No.87/12.68)

12.69 KSRB 11-18.8.2 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 75x75x75x75mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 525.00
KBS 11-1.10 (PWD SR2011-12/P.No.87/12.69)

12.70 KSRB 11-18.8.3 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 50x50x50x50mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 454.00
KBS 11-1.10 (PWD SR2011-12/P.No.87/12.70)

12.71 KSRB 11-18.9.1 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 100x100x100mm,
including cost of materials, labour, testing complete as per specifications. Each 667.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.87/12.71)

12.72 KSRB 11-18.10.1 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 100x100x75x75mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 843.00
KBS 11-1.10 (PWD SR2011-12/P.No.87/12.72)

12.73 KSRB 11-18.11.1 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 100x100x75mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 374.00
(PWD SR2011-12/P.No.87/12.73)

12.74 KSRB 11-18.11.2 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 100x100x50mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 356.00
(PWD SR2011-12/P.No.87/12.74)

12.75 KSRB 11-18.11.3 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 75x75x50mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 328.00
(PWD SR2011-12/P.No.87/12.75)
12.76 KSRB 11-18.12.1 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 100x100x100x100mm,
including cost of materials, labour, testing complete as per specifications. Each 721.00
KBS 11.1.10 (PWD SR2011-12/P.No.87/12.76)

12.77 KSRB 11-18.12.2 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 75x75x75x75mm, including
cost of materials, labour, testing complete as per specifications. KBS 11- Each 507.00
1.10 (PWD SR2011-12/P.No.88/12.77)

12.78 KSRB 11-18.12.3 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 50x50x50x50mm, including
cost of materials, labour, testing complete as per specifications. KBS 11- Each 454.00
1.10 (PWD SR2011-12/P.No.88/12.78)

12.79 KSRB 11-18.13.1 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 100x100x100x100mm,
including cost of materials, labour, testing complete as per specifications.
Specification No. KBS 11.1.10 (PWD SR2011-12/P.No.88/12.79) Each 721.00

12.80 KSRB 11-18.13.2 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 75x75x75x75mm, including
cost of materials, labour, testing complete as per specifications. Each 507.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.88/12.80)

12.81 KSRB 11-18.13.3 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 50x50x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 454.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.88/12.81)

12.82 KSRB 11-18.14.1 : Providing and fixing sand cast iron soil waste double
unequal invert plain branches of required degree 100x100x75x75mm,
including cost of materials, labour, testing complete as per specifications. Each 843.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.88/12.82)

12.83 KSRB 11-18.14.2 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 75x75x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 403.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.88/12.83)

12.84 KSRB 11-18.15.1 : Providing and fixing sand cast iron soil waste single
unequal invert plain branches of required degree 100x100x75mm,
including cost of materials, labour, testing complete as per specifications. Each 374.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.88/12.84)
12.85 KSRB 11-18.15.2 : Providing and fixing sand cast iron soil waste single
unequal invert plain branches of required degree 75x75x50mm, including
cost of materials, labour, testing complete as per specifications. Each 328.00
Specification No. KBS 11-1.10 (PWD SR2011-12/P.No.88/12.85)

12.86 KSRB 11-18.16.1 : Providing and fixing sand cast iron soil waste 152mm
offsets for 100mm pipes, including cost of materials, labour, testing
complete as per specifications. Specification No. KBS 11-1.10 (PWD Each 501.00
SR2011-12/P.No.88/12.86)

12.87 KSRB 11-18.16.2 : Providing and fixing sand cast iron soil waste 114mm
offsets for 75mm pipes, including cost of materials, labour, testing
complete as per specifications. Specification No. KBS 11-1.10 (PWD Each 325.00
SR2011-12/P.No.88/12.87)

12.88 KSRB 11-18.16.3 : Providing and fixing sand cast iron soil waste 230mm
offsets for 75mm pipes, including cost of materials, labour, testing
complete as per specifications. Specification No. KBS 11-1.10 (PWD Each 765.00
SR2011-12/P.No.89/12.88)

12.89 KSRB 11-18.17.1 : Providing and fixing sand cast iron trap of 100mm dia,
of self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing complete as per specifications. Specification No. Each 632.00
KBS 11-1.10 (PWD SR2011-12/P.No.89/12.89)

12.90 KSRB 11-18.17.2 : Providing and fixing sand cast iron trap of 75mm dia, of
self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing complete as per specifications. Specification No. Each 536.00
KBS 11-1.10 (PWD SR2011-12/P.No.89/12.90)

12.91 KSRB 11-18.17.3 : Providing and fixing sand cast iron trap of 50mm dia, of
self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing complete as per specifications. Specification No. Each 456.00
KBS 11-1.10 (PWD SR2011-12/P.No.89/12.91)

12.92 KSRB 11-18.18.1 : Providing lead caulked joints to sand cast iron/cast iron
(spun) pipes and fittings of 100mm dia, including cost of materials, labour,
testing complete as per specifications. specification No.KBS 13-2.7 (PWD Joint 87.30
SR2011-12/P.No.89/12.92)

12.93 KSRB 11-18.18.2 : Providing lead caulked joints to sand cast iron/cast iron
(spun) pipes and fittings of 75 mm dia, including cost of materials, labour,
testing complete as per specifications. specification No.KBS 13-2.7 (PWD Joint 75.80
SR2011-12/P.No.89/12.93)
12.94 KSRB 11-18.18.3 : Providing lead caulked joints to sand cast iron/cast iron
(spun) pipes and fittings of 50 mm dia, including cost of materials, labour,
testing complete as per specifications. specification No.KBS 13-2.7 (PWD Joint 64.20
SR2011-12/P.No.89/12.94)

12.95 KSRB 11-18.9.2 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 75x75x75mm, including
cost of materials, labour, testing complete as per specifications. Each 472.00
specification No.KBS 11.1.10 (PWD SR2011-12/P.No.89/12.95)

12.96 KSRB 11-18.9.3 : Providing and fixing sand cast iron soil waste single
equal junction of required degree with access door 50x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 400.00
specification No.KBS 11.1.10 (PWD SR2011-12/P.No.89/12.96)

12.97 KSRB 11-18.10.2 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 100x100x50x50mm, including cost of
materials, labour, testing complete as per specifications. specification Each 814.00
No.KBS 11.1.10 (PWD SR2011-12/P.No.89/12.97)

12.98 KSRB 11-18.10.3 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 75x75x50x50mm, including cost of
materials, labour, testing complete as per specifications. specification Each 403.00
No.KBS 11.1.10 (PWD SR2011-12/P.No.90/12.98)

12.99 KSRB 11-18.19.1 : Providing and fixing M.S. stays and clamps for sand
cast iron pipes of 100mm dia including cost of materials, labour complete
as per specifications. (PWD SR2011-12/P.No.90/12.99) No. 165.00

12.100 KSRB 11-18.19.2 : Providing and fixing M.S. stays and clamps for sand
cast iron pipes of 75mm dia including cost of materials, labour complete as No. 149.00
per specifications. (PWD SR2011-12/P.No.90/12.100)

12.101 KSRB 11-18.19.3 : Providing and fixing M.S. stays and clamps for sand
cast iron pipes of 50mm dia including cost of materials, labour complete as
per specifications. (PWD SR2011-12/P.No.90/12.101) No. 37.92

12.103 Providing (China clay) glzed foot rests of approved 1st quality and make
conforming to ISI Specifications and fixing in CM (1:3) as directed (Rate
includes cost of materials and conveyance to work spot).PWD SR2011-12/ Pair 150.00
P.No.90/12.103
12.104 Providing plastic seat with approved 1st quality and make conforming to
ISI specifications double flapped and fixing to English water closet with all
fittings (Rate includes cost of materials, fixtures and conveyance to work
spot.PWD SR2011-12/ P.No.90/12.104

12.104. Providing White plastic seat with approved 1st quality and make
1 conforming to ISI specifications double flapped and fixing to English water
closet with all fittings (Rate includes cost of materials, fixtures and Pair 250.00
conveyance to work spot.PWD SR2011-12/ P.No.90/12.104.1

12.104. Providing Black plastic seat with approved 1st quality and make
2 conforming to ISI specifications double flapped and fixing to English water
closet with all fittings (Rate includes cost of materials, fixtures and Pair 200.00
conveyance to work spot.PWD SR2011-12/ P.No.90/12.104.2

12.105 Providing 3 cms dia GI telescopic flush tank lever of approved 1st quality
and make conforming to ISI specifications and fixing in position as directed
by the Engineer. Rate includes cost of materials and conveyance to work Each 220.00
spot.PWD SR2011-12/ P.No.90/12.105

12.106 Providing vulcanizing or rubber float of approved st quality and make


conforming to ISI Specifications and fixing for low down cistern as directed
by the Engineer. Rate includes cost of materials and conveyance to work Each 167.00
spot. PWD SR2011-12/ P.No.90/12.106

12.107 Providing wash basin brackets of approved 1st quality and make
conforming to ISI Specifications and fixing for low down cistern as directed.
Rate includes cost of materials and conveyance to work spot.PWD Pair 207.00
SR2011-12/ P.No.90/12.107

12.108 Providing pedestal for wash basin of approved 1sty quality and make
coforming to ISI Specifications and fixing for low down cistern as directed.
Rate includes cost of materials and conveyance to work spot.PWD Each 835.00
SR2011-12/ P.No.90/12.108

12.109 Providing and fixing white vitreous china clay urinals with flat back of
approved make fixed to wooden plug including bends, painting white to
exposed pipes etc., complete as per directions. (rate includes cost of all Each 820.00
materials and lead). A grade.PWD SR2011-12/ P.No.90/12.109

12.110 Providing white vitreous china clay Indian pattern squatting urinals with
white glazed foot rests of approved quality and make conforming to ISI
Specifications and fixing in position with CC 1:2:4 as directed of size 50.8
cms X 38 cms X 10.16 cms- A Grade (Rate includes cost of all materials Each 920.00
and conveyance to work spot).PWD SR2011-12/ P.No.91/12.110
12.111 Providing and fixing 7.5 cms to 15.00 cms dia NP gating 100 mm dia.PWD
Each 145.00
SR2011-12/ P.No.91/12.111

12.112 Providing stonware gully trap of approved quality and make fixing in CC
1:2:4 and plastering with CM 1:3 wherever necessary. ( Rate includes cost
of all materials, fixtures and lead).PWD SR2011-12/ P.No.91/12.112

12.112. Providing stonware gully trap of size 10cms X 10cms approved quality
1 and make fixing in CC 1:2:4 and plastering with CM 1:3 wherever
necessary. ( Rate includes cost of all materials, fixtures and lead).PWD Each 175.00
SR2011-12/ P.No.91/12.112.1

12.112. Providing stonware gully trap of size 15cms X 10cms approved quality
2 and make fixing in CC 1:2:4 and plastering with CM 1:3 wherever
necessary. ( Rate includes cost of all materials, fixtures and lead).PWD Each 250.00
SR2011-12/ P.No.91/12.112.2

12.113 Providing and fixing CI Nahani trap of approved make conforming to ISI
Specifications and construction of cistern in CC 1:2:4 as per directions
( Rate is inclusive of cost materials and fixtures and conveyance of
materials to work spot).PWD SR2009-10/ P.No.76/12.113

12.113. Providing and fixing CI Nahani trap of size 10 cms X 7.5cms approved
1 make conforming to ISI Specifications and construction of cistern in CC
1:2:4 as per directions ( Rate is inclusive of cost materials and fixtures and Each 220.00
conveyance of materials to work spot).PWD SR2011-12/ P.No.91/12.113.1

12.113. Providing and fixing CI Nahani trap of size 12.5cms X 7.5cms approved
2 make conforming to ISI Specifications and construction of cistern in CC
1:2:4 as per directions ( Rate is inclusive of cost materials and fixtures and Each 270.00
conveyance of materials to work spot).PWD SR2011-12/ P.No.91/12.113.2

12.113b -Do- with scaffolding m 50.00

12.113c -do- without scaffolding m 40.00

12.113d -do- underground stone warepipes m 16.00


WATER SUPPLY WORK

13.1 KSRB 13-1.1: Providing and fixing to wall, ceiling and floor, galvanised / mild
steel tube 15mm dia nominal bore with fittings (medium grade weight 1.27
kg/mtr) B class including cost of all materials, labour charges, HOM of m 128.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.14/13.8 (PWD SR2011-12/P.No.93/13-1)

13.2 KSRB 13-1.2 : Providing and fixing to wall, ceiling and floor, galvanised / mild
steel tube 20mm dia nominal bore with fittings (medium grade weight 1.65
kg/mtr) B class including cost of all materials, labour charges, HOM of m 158.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.14/13.8 (PWD SR2011-12/P.No.93/13.2)

13.3 KSRB 13-1-3 : Providing and fixing to wall, ceiling and floor, galvanised / mild
steel tube 25mm dia nominal bore with fittings (medium grade weight 2.51
kg/mtr) B class including cost of all materials, labour charges, HOM of m 217.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.14/13.8 (PWD SR2011-12/P.No.93/13.3)

13.4 KSRB 13-1-4 : Providing and fixing to wall, ceiling and floor, galvanised / mild
steel tube 32mm dia nominal bore with fittings (medium grade weight 3.23
kg/mtr) B class including cost of all materials, labour charges, HOM of m 237.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.14/13.8 (PWD SR2011-12/P.No.93/13.4)

13.5 KSRB 13-1-5 : Providing and fixing to wall, ceiling and floor, galvanised / mild
steel tube 40mm dia nominal bore with fittings (medium grade weight 3.72
kg/mtr) B class including cost of all materials, labour charges, HOM of m 311.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.14/13.8 (PWD SR2011-12/P.No./13.5)

13.6 KSRB 13-1-6 : Providing and fixing to wall, ceiling and floor, galvanised / mild
steel tube 50mm dia nominal bore with fittings (medium grade weight 5.24
kg/mtr) B class including cost of all materials, labour charges, HOM of m 338.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.14/13.8 (PWD SR2011-12/P.No.93/13.6)

13.7 KSRB 13-2-1 : Extra for concealed pipe including painting with anticorrosive
bitumastic paint cutting chases, making good the concrete surface, and plaster
for 15mm dia nominal bore including cost of all materials, labour charges,
m 81.00
HOM of equipments complete as per specifications. (PWD SR2011-
12/P.No.93/13.7)

13.8 KSRB 13-2-2 : Extra for concealed pipe including painting with anticorrosive
bitumastic paint cutting chases, making good the concrete surface, and plaster
for 20mm dia nominal bore including cost of all materials, labour charges, m 81.00
HOM of equipments complete as per specifications. (PWD SR2011-
12/P.No.93/13.8)
13.9 KSRB 13-2-3 : Extra for concealed pipe including painting with anticorrosive
bitumastic paint cutting chases, making good the concrete surface, and plaster
for 25mm dia nominal bore including cost of all materials, labour charges, m 81.00
HOM of equipments complete as per specifications. (PWD SR2011-
12/P.No.94/13.9)

13.10 KSRB 13-3-1 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 15mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 103.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.94/13.10)

13.11 KSRB 13-3-2 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 20mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 130.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.94/13.11)

13.12 KSRB 13-3-3 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 25mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 190.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.94/13.12)

13.13 KSRB 13-3-4 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 32mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 203.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.94/13.13)

13.14 KSRB 13-3-5 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 40mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 271.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No. 94/13.14)

13.15 KSRB 13-3-6 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 50mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 283.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.94/13.15)
13.16 KSRB 13-3-7 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 65mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 442.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.94/13.16)

13.17 KSRB 13-3-8 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 80mm dia nominal bore with all fittings (earth work in trenches
to be measured and paid for separately) including cost of all materials, labour
charges, HOM of equipments and testing complete as per specifications. m 571.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.95/13.17)

13.18 KSRB 13-3-9 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 100mm dia nominal bore with all fittings (earth work in
trenches to be measured and paid for separately) including cost of all materials,
labour charges, HOM of equipments and testing complete as per specifications. m 729.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.95/13.18)

13.19 KSRB 13-3-10 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 150mm dia nominal bore with all fittings (earth work in
trenches to be measured and paid for separately) including cost of all materials,
labour charges, HOM of equipments and testing complete as per specifications. m 1093.00
Specification No. KBS 13.2.14/13.6 (PWD SR2011-12/P.No.95/13.19)

13.20 KSRB 13-4-1 : Making connection of G.I. distribution branch with G.I. main
of 25 to 40mm nominal bore, including cutting and threading the pipes,
providing and fixing Tee, nuts, labour for all item of works, testing and HOM of Nos 281.00
equipments complete as per specifications. Specification No. KBS
13.2.14/13.10 (PWD SR2011-12/P.No.95/13.20)

13.21 KSRB 13-4-2 : Making connection of G.I. distribution branch with G.I. main of
50 to 85mm and 100 to 150 nominal bore, including cutting and threading the
pipe, providing and fixing Tee, nuts, labour for all item of works, testing and Nos 523.00
HOM of equipments complete as per specifications. Specification No. KBS
13.10 (PWD SR2011-12/P.No.95/13.21)

13.22 KSRB 13-5 : Providing and fixing water meter with stop cock, jam nut, socket in
G.I pipe line including cutting and threading the pipe and making long screws
including cost of all materials, labour, HOM of equipments and testing complete Set 901.00
as per specifications. Specification No. KBS 13.2.19/13.16 (PWD SR2011-
12/P.No.94/13.22)

13.23 KSRB 13-6.1-1 : Providing and fixing in position brass bib cock of approved
quality 15mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 139.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.95/13.23)
13.24 KSRB 13-6.1-2 : Providing and fixing in position brass bib cock of approved
quality 20mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 173.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.95/13.24)

13.25 KSRB 13-6.1-3 : Providing and fixing in position brass bib cock of approved
quality 25mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 184.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.25)

13.26 KSRB 13-6.2-1 : Providing and fixing in position brass stop cock of approved
quality 15mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 128.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.26)

13.27 KSRB 13-6.2-2 : Providing and fixing in position brass stop cock of approved
quality 20mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 128.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.27)

13.28 KSRB 13-6.2-3 : Providing and fixing in position brass stop cock of approved
quality 25mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 128.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.28)

13.29 KSRB 13-6.2-4 : Providing and fixing in position brass stop cock of approved
quality 32mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 127.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.29)

13.30 KSRB 13-6.2-5 : Providing and fixing in position brass stop cock of approved
quality 40mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 127.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.30)

13.31 KSRB 13-6.2-6 : Providing and fixing in position brass stop cock of approved
quality 50mm nominal bore including cost of all materials, labour, HOM of
equipments with all leads complete as per specifications. Specification No. Each 125.00
KBS 13.2.2/13.3 (PWD SR2011-12/P.No.96/13.31)

13.32 KSRB 13-6.3-1 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 15mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 288.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.96/13.32)

13.33 KSRB 13-6.3-2 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 20mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 383.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.96/13.33)
13.34 KSRB 13-6.3-3 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 25mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 546.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.97/13.34)

13.35 KSRB 13-6.3-4 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 32mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 784.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.97/13.35)

13.36 KSRB 13-6.3-5 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 40mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 987.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.80/13.36)

13.37 KSRB 13-6.3-6 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 50mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 1493.00
specifications.(PWD SR 2011-12/P.No. 97/13.37)

13.38 KSRB 13-6.3-7 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 65mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 1861.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.97/13.38)

13.39 KSRB 13-6.3-8 : Providing and fixing in position brass gate valve with C.I.
wheel of approved quality (screwed end) 80mm nominal bore including cost of
all materials, labour, HOM of equipments with all leads complete as per Each 2225.00
specifications. Specification No. KBS 13.2.6/13.3 (PWD SR2011-
12/P.No.97/13.39)

13.40 KSRB 13-6.4-1 : Providing and fixing in position brass ball valve high or low
pressure with plastic float of approved quality 15mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete as Each 243.00
per specifications. (PWD SR2011-12/P.No.97/13.40)

13.41 KSRB 13-6.4-2 : Providing and fixing in position brass ball valve high or low
pressure with plastic float of approved quality 20mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete as Each 397.00
per specifications. (PWD SR2011-12/P.No.97/13.41)

13.42 KSRB 13-6.4-3 : Providing and fixing in position brass ball valve high or low
pressure with plastic float of approved quality 25mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete as Each 527.00
per specifications. (PWD SR2011-12/P.No.97/13.42)
13.43 KSRB 13-6.5-1 : Providing and fixing in position 15mm nominal bore brass
ferrule with C.I. mouth cover including boring and tapping the main, cost of all
materials, labour and HOM of equipments with all leads complete as per Each 158.00
specifications. Specification No. KBS 13.2.3/13.14 (PWD SR2011-
12/P.No.98/13.43)

13.44 KSRB 13-6.5-2 : Providing and fixing in position 20mm nominal bore brass
ferrule with C.I. mouth cover including boring and tapping the main, cost of all
materials, labour and HOM of equipments with all leads complete as per Each 221.00
specifications. Specification No. KBS 13.2.3/13.14 (PWD SR2011-
12/P.No.98/13.44)

13.45 KSRB 13-6.5-3 : Providing and fixing in position 25mm nominal bore brass
ferrule with C.I. mouth cover including boring and tapping the main, cost of all
materials, labour and HOM of equipments with all leads complete as per Each 256.00
specifications. Specification No. KBS 13.2.3/13.14 (PWD SR2011-
12/P.No.98/13.45)

13.46 KSRB 13-6.6-1 : Providing and fixing unplasticised PVC connection pipe with
brass union 15mm nominal bore 300 mm length of PVC connection including
cost of all materials, labour and HOM of equipments with all leads complete as Set 247.00
per specifications. (PWD SR2011-12/P.No.98/13.46)

13.47 KSRB 13-6.6-2 : Providing and fixing unplasticised PVC connection pipe with
brass union 15mm nominal bore 450 mm length of PVC connection including
cost of all materials, labour and HOM of equipments with all leads complete as Set 312.00
per specifications. (PWD SR2011-12/P.No.98/13.47)

13.48 KSRB 13-6.6-3 : Providing and fixing unplasticised PVC connection pipe with
brass union 20mm nominal bore 300 mm length of PVC connection including
cost of all materials, labour and HOM of equipments with all leads complete as Set 265.00
per specifications. (PWD SR2011-12/P.No.98/13.48)

13.49 KSRB 13-6.6-4 : Providing and fixing unplasticised PVC connection pipe with
brass union 20mm nominal bore 450 mm length of PVC connection including
cost of all materials, labour and HOM of equipments with all leads complete as Set 290.00
per specifications. (PWD SR2011-12/P.No.98/13.49)

13.50 KSRB 13-6.7-1 : Providing and fixing in position chromium plated brass shower
rose with 15 or 20mm inlet 100mm dia including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Each 511.00
No. KBS 13.2.16/13.3(PWD SR2011-12/P.No.98/13.50)

13.51 KSRB 13-6.7-2 : Providing and fixing in position chromium plated brass shower
rose with 15 or 20mm inlet 150mm dia including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Each 545.00
Specification No. KBS 13.2.16/13.3 (PWD SR2011-12/P.No.98/13.51)
13.52 KSRB 13-7.1.1 : Providing and fixing in position 25mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Nos. 441.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.52)

13.53 KSRB 13-7.1.2 : Providing and fixing in position 32mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Nos. 624.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.53)

13.54 KSRB 13-7.1.3 : Providing and fixing in position 40mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Each 745.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.54)

13.55 KSRB 13-7.1.4 : Providing and fixing in position 50mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Nos. 1051.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.55)

13.56 KSRB 13-7.1.5 : Providing and fixing in position 65mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Nos. 1483.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.56)

13.57 KSRB 13-7.1.6 : Providing and fixing in position 80mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Nos. 1850.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.57)

13.58 KSRB 13-7.1.7 : Providing and fixing in position 100mm nominal bore gun metal
non-return valve horzontal type of approved make including cost of all
materials, labour and HOM of equipments with all leads complete as per Nos. 2219.00
specifications. Specification No. KBS 13.2.10/13.13 (PWD SR2011-
12/P.No.99/13.58)

13.59 KSRB 13-7.2.1 : Providing and fixing in position 25mm nominal bore non-return
valve vertical type of approved make including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Nos. 382.00
No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.99/13.59)

13.60 KSRB 13-7.2.2 : Providing and fixing in position 32mm nominal bore non-return
valve vertical type of approved make including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Nos. 567.00
No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.99/13.60)
13.61 KSRB 13-7.2.3 : Providing and fixing in position 40mm nominal bore non-return
valve vertical type of approved make including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Nos. 690.00
No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.100/13.61)

13.62 KSRB 13-7.2.4 : Providing and fixing in position 50mm nominal bore non-return
valve vertical type of approved make including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Nos. 998.00
No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.100/13.62)

13.63 KSRB 13-7.2.5 : Providing and fixing in position 65mm nominal bore non-return
valve vertical type of approved make including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Nos. 1366.00
No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.100/13.63)

13.64 KSRB 13-7.2.6 : Providing and fixing in position 80mm nominal bore non-return
valve vertical type of approved make including cost of all materials, labour and
HOM of equipments with all leads complete as per specifications. Specification Nos. 1732.00
No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.100/13.64)

13.65 KSRB 13-7.2.7 : Providing and fixing in position 100mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per specifications. Nos. 1976.00
Specification No. KBS 13.2.10/13.13 (PWD SR2011-12/P.No.100/13.65)

13.66 KSRB 13-8.1 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 20mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 67.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.1/13.9 (PWD SR2011-12/P.No.100/13.66)

13.67 KSRB 13-8.2 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 25mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 82.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.1/13.9 (PWD SR2011-12/P.No.100/13.67)

13.68 KSRB 13-8.3 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 140.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.1/13.9 (PWD SR2011-12/P.No.100/13.68)
13.69 KSRB 13-8.4 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 40mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 164.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.1/13.9 (PWD SR2011-12/P.No.101/13.69)

13.70 KSRB 13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 204.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.1/13.9 (PWD SR2011-12/P.No.101/13.70)

13.71 KSRB 13-9.1 : Providing and fixing to wall, ceiling and floor, high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 166.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.2/13.9 (PWD SR2011-12/P.No.101/13.70.1)

13.72 KSRB 13-9.2 : Providing and fixing to wall, ceiling and floor, high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 204.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.2/13.9 (PWD SR2011-12/P.No.101/13.70.2)

13.73 KSRB 13-9.3 : Providing and fixing to wall, ceiling and floor, high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 269.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.2/13.9 (PWD SR2011-12/P.No.101/13.70.2.3)

13.74 KSRB 13-10.1 : Providing and fixing to wall, ceiling and floor, unplasticised PVC
pipes 10.00 kgf/sq.cm working pressure 16mm out side diameter chemp plast/
Wavin or equivalent make with pipe fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 64.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.4/13.9 (PWD SR2011-12/P.No.101/13.70.2.4)

13.75 KSRB 13-10.2: Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 140mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 71.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.4/13.9 (PWD SR2011-12/P.No.101/13.70.2.5)
13.76 KSRB 13-10.3: Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 160mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 77.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.4/13.9 (PWD SR2011-12/P.No.102/13.70.2.6)

13.77 KSRB 13-10.4 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 84.00
equipments and testing complete as per specifications. Specification No. KBS
13.2.15.4/13.9 (PWD SR2011-12/P.No.102/13.71)

13.78 KSRB 13-11.1 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 40mm out side diameter
with special flange, compression type fittings, wall clips, making good the wall,
ceiling and floor including cost of all materials, labour charges, HOM of m 6451.00
equipments and testing complete as per specifications. Specification No. KBS
13.22 (PWD SR2011-12/P.No.102/13.72)

13.79 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete.(PWD
SR2011-12/P.No.102/13.79)

13.79.1 Providing and fixing for 15mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift etc., Each 265.00
complete.(PWD SR2011-12/P.No.102/13.79.1)

13.79.2 Providing and fixing for 20mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift etc., Each 330.00
complete.(PWD SR2011-12/P.No.102/13.79.2)

13.79.3 Providing and fixing for 25mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift etc., Each 460.00
complete.(PWD SR2011-12/P.No.102/13.79.3)

13.79.4 Providing and fixing for 32mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift etc., Each 670.00
complete.(PWD SR2011-12/P.No.102/13.79.4)

13.79.5 Providing and fixing for 40mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift etc., Each 850.00
complete.(PWD SR2011-12/P.No.102/13.79.5)

13.79.6 Providing and fixing for 50mm dia gun metal wheel valve conforming to IS
specification of approved make as per directions including all lead and lift etc., Each 1300.00
complete.(PWD SR2011-12/P.No.102/13.79.6)
13.80 Providing gun metal pillar ocks 15mm dia of I class conforming to ISI
Specifications and fixing them in position as per directions including of cost of
materials and fixtures and conveyance to spot.(PWD SR2011- Each 225.00
12/P.No.102/13.80)

13.81 Providing NP/CP waste unions conforming to ISI specifications and fixing
themin position as per directions including cost of materials, fixtures and
conveyance to work spot etc., complete.(PWD SR2011-12/P.No.102/13.81)

13.81.1 Providing NP/CP waste unions conforming to ISI specifications and fixing for
32mm dia themin position as per directions including cost of materials, fixtures
and conveyance to work spot etc., complete.(PWD SR2011- Each 110.00
12/P.No.102/13.81.1)

13.81.2 Providing NP/CP waste unions conforming to ISI specifications and fixing for
40mm dia themin position as per directions including cost of materials, fixtures
and conveyance to work spot etc., complete.(PWD SR2011- Each 140.00
12/P.No.102/13.81.2)

13.81.3 Providing NP/CP waste unions conforming to ISI specifications and fixing for
50mm dia themin position as per directions including cost of materials, fixtures
and conveyance to work spot etc., complete.(PWD SR2011- Each 190.00
12/P.No.102/13.81.3)

13.82 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite


pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers,
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. ( Internal
work) (PWD SR2011-12/P.No.103/13.82)

Pipes exposed on wall


13.82.1 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite
pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers, m 155.00
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. 1216 (16 mm
OD) pipe (PWD SR2011-12/P.No.103/13.82.1)
13.82.2 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite
pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers, m 190.00
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. 1620 (20mm
OD) pipe (PWD SR2011-12/P.No.103/13.82.2)

13.82.3 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite


pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers,
m 250.00
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. 2025 (25mm
OD) pipe (PWD SR2011-12/P.No.103/13.82.3)

13.82.4 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite


pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers, m 360.00
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. 2532 (32 mm
OD) pipe (PWD SR2011-12/P.No.103/13.82.4)

13.82.5 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite


pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers, m 450.00
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. 3240 (40mm
OD) pipe (PWD SR2011-12/P.No.103/13.82.5)

13.82.6 Providing & fixing polythelen-Aluminium-Polythelene (PE-AL-PE) composite


pressure pipes conforming to IS 15450 duly "ISI" marked, U.V. stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings (engineering
plastic blend and brass inserts wherever required.) e.g. elbows, tees, reducers, m 540.00
couplers & connectores etc., with clamps at 1.00 meter spacing, cutting &
making good the wall etc., including testing complete as required. 4050 (50mm
OD) pipe (PWD SR2011-12/P.No.103/13.82.6)
13.83 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote
pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and
every fitting, cutting & making good the walls etc., including testing complete as
required. (Internal work) (PWD SR2011-12/P.No.103/13.83)

Concealed piping with cutting chases & making


good walls etc.,
13.83.1 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote
pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
m 220.00
couplers & connectors etc., with cement taking at 1.00 meter spacing, and
every fitting, cutting & making good the walls etc., including testing complete as
required. 1216 (16 mm OD) pipe (PWD SR2011-12/P.No.103/13.83.1)

13.83.2 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 260.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 2025 (25 mm OD) pipe (PWD SR2011-12/P.No.103/13.83.2)

13.83.3 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 310.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 2025 (25 mm OD) pipe (PWD SR2011-12/P.No.103/13.83.3)
13.83.4 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote
pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 400.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 2532 (32 mm OD) pipe (PWD SR2011-12/P.No.103/13.83.4)

13.83.5 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 520.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 3240 (40 mm OD) pipe (PWD SR2011-12/P.No.103/13.83.5)

13.83.6 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
m 680.00
couplers & connectors etc., with cement taking at 1.00 meter spacing, and
every fitting, cutting & making good the walls etc., including testing complete as
required. 4050 (50mm OD) pipe (PWD SR2011-12/P.No.103/13.83.6)

13.84 Providing & fixing Polyethelene-Aluminium- Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.
stablized with Carbon black for hot & cold water supply, capable to withstand
temparature upto 80 degree centigrade incluiding all soecial composite fittings
(Engineering plastic blend and brass inserts wherever requiored.) e.g. elbows,
tees, reducers, couplers & connectors etc., with tranching & refilling upto 1.00
meter depth including testiong complete as required. (External work) (PWD
SR2011-12/P.No.103/13.84))

Pipe in trenches including excavation &


refilling etc.,
13.84.1 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote
pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 150.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 1216 (16 mm OD) pipe (PWD SR2011-12/P.No.104/13.84.1)
13.84.2 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote
pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 200.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 1620 (20 mm OD) pipe (PWD SR2011-12/P.No.104/13.84.2)

13.84.3 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 250.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 2025 (25mm OD) pipe (PWD SR2011-12/P.No.104/13.84.3)

13.84.4 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 320.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 2532 (32 mm OD) pipe ((PWD SR2011-12/P.No.104/13.84.4)

13.84.5 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
couplers & connectors etc., with cement taking at 1.00 meter spacing, and m 420.00
every fitting, cutting & making good the walls etc., including testing complete as
required. 3240 (40 mm OD) pipe (PWD SR2011-12/P.No.104/13.84.5)

13.84.6 Providing & fixing polythelene-Aluminium-Polyethelene (PE-AL-PE) Composote


pressure Pipes conforming to IS 15450 duly "ISI" marked, U.V.stabalized with
Carbon black for hot & cold water supply, capable to withstand temparature
upto 80 degree centigrade including all special composite fittings ( Engineering
plastic blend and brass inserts wherever required.) e.g.elbows, tees, reducers,
m 520.00
couplers & connectors etc., with cement taking at 1.00 meter spacing, and
every fitting, cutting & making good the walls etc., including testing complete as
required. 4050 (50 mm OD) pipe (PWD SR2011-12/P.No.104/13.84.6)
13.85 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV
solvent cement and testing of joints complete. (internal work exposed on wall)
PWD SR 2011-12/ P.No.104/13.85)

13.85.1 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV 100.00
solvent cement and testing of joints complete. (internal work exposed on wall)
15mm nominal OD pipes (PWD SR 2011-12/ P.No.104/13.85.1)

13.85.2 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV 120.00
solvent cement and testing of joints complete. (internal work exposed on wall)
20 mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.85.1)

13.85.3 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV 150.00
solvent cement and testing of joints complete. (internal work exposed on wall)
25 mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.85.1)

13.85.4 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV 200.00
solvent cement and testing of joints complete. (internal work exposed on wall)
32 mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.85.1)

13.85.5 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV 280.00
solvent cement and testing of joints complete. (internal work exposed on wall)
40 mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.85.1)

13.85.6 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV 410.00
solvent cement and testing of joints complete. (internal work exposed on wall)
50 mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.85.1)
13.86 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV
solvent cement and the cost of cutting chases & making good the same
including testing of joints complete.(concealed work including cutting chases
and good the walls etc.,) PWD SR 2011-12/ P.No.104-85/13.86)

13.86.1 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV
solvent cement and the cost of cutting chases & making good the same m 115.00
including testing of joints complete.(concealed work including cutting chases
and good the walls etc.,) 15 mm nominal OD pipes PWD SR 2011-12/
P.No.104/13.86)

13.86.2 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV
solvent cement and the cost of cutting chases & making good the same m 180.00
including testing of joints complete.(concealed work including cutting chases
and good the walls etc.,) 20 mm nominal OD pipes PWD SR 2011-12/
P.No.104/13.86)

13.86.3 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV
solvent cement and the cost of cutting chases & making good the same
m 220.00
including testing of joints complete.(concealed work including cutting chases
and good the walls etc.,) 25 mm nominal OD pipes PWD SR 2011-12/
P.No.104/13.86)

13.86.4 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including fixing the pipe with clamp at
1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPCV
solvent cement and the cost of cutting chases & making good the same m 280.00
including testing of joints complete.(concealed work including cutting chases
and good the walls etc.,) 32 mm nominal OD pipes PWD SR 2011-12/
P.No.11-12/13.86)

13.87 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete.
PWD SR 2009-10/ P.No.84-85/13.87)
13.87.1 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 95.00
15mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.87.1)

13.87.2 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 110.00
20mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.87.2)

13.87.3 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 140.00
25mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.87.3)

13.87.4 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 190.00
32mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.87.4)

13.87.5 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 270.00
40mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.87.5)

13.87.6 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 400.00
50mm nominal OD pipes PWD SR 2011-12/ P.No.104/13.87.6)

13.87.7 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 1250.00
62.50mm nominal OD pipes PWD SR 2011-12/ P.No.105/13.87.7)

13.87.8 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 1550.00
75mm nominal OD pipes PWD SR 2011-12/ P.No.105/13.87.8)
13.87.9 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 2150.00
100mm nominal OD pipes PWD SR 2011-12/ P.No.105/13.87.9)

13.87.10 Providing and fixing Chorinated Poly Venyl Choride (CPVC) pipes conforming
to IS 15778, having thermal stability for hot and cold water supply including all
CPVC plain and brass threaded fittings this includes jointing of pipes and fittings
with one step solvent cement, trenching, refilling & testing of joints complete. m 3750.00
150mm nominal OD pipes (PWD SR 2011-12/ P.No.105/13.87.10)

13.88 Providing and fixing polished granite sink of size 60cmsx 90cms of 23cm thick,
the sink portion shall be 15cm in depth of shapes oval / round / square over
brick masonry in cement mortar 1:6 including cost and conveyance of all
materials, labour for all items of work, HOM of equipment with all lead and lift,
loading and un loading, transportation charges and all other incidental charges Each 5852.00
etc., complete as per specification and directions of the Engineer-in-charge of
work.(PWD SR 2011-12/ P.No.105/13.88)

13.89 Providing and fixing polished granite sink of size 60cmsx 75cms of 23cm thick,
the sink portion shall be 15cm in depth of shapes oval / round / square over
brick masonry in cement mortar 1:6 including cost and conveyance of all
materials, labour for all items of work, HOM of equipment with all lead and lift,
loading and un loading, transportation charges and all other incidental charges Each 4923.00
etc., complete as per specification and directions of the Engineer-in-charge of
work.(PWD SR 2011-12/ P.No.105/13.89)

13.90 Providing and fixing polished granite sink of size 60cmsx 60cms of 23cm thick,
the sink portion shall be 15cm in depth of shapes oval / round / square over
brick masonry in cement mortar 1:6 including cost and conveyance of all
materials, labour for all items of work, HOM of equipment with all lead and lift,
loading and un loading, transportation charges and all other incidental charges Each 3994.00
etc., complete as per specification and directions of the Engineer-in-charge of
work.(PWD SR 2011-12/ P.No.105/13.90)

13.91 Providing and fixing polished granite sink of size 60cmsx 45cms of 20cm thick,
the sink portion shall be 15cm in depth of shapes oval / round / square over
brick masonry in cement mortar 1:6 including cost and conveyance of all
materials, labour for all items of work, HOM of equipment with all lead and lift,
loading and un loading, transportation charges and all other incidental charges Each 605.00
etc., complete as per specification and directions of the Engineer-in-charge of
work.(PWD SR 2011-12/ P.No.105/13.91)

13.92 Cutting granite slab upto 40mm thick and required width of grooves for fixing
stainless steel sink and fixing using adhesives.(PWD SR 2011-12/ P.No.
105/13.92)

13.92.1 Cutting granite slab upto 40mm thick and required width of grooves for fixing
stainless steel sink and fixing using adhesives.(60cmx45cms). (PWD SR 2011- No 452.00
12/ P.No. 105/13.92.1)
13.92.2 Cutting granite slab upto 40mm thick and required width of grooves for fixing
stainless steel sink and fixing using adhesives.(60cmx45cms). (PWD SR 2011- No 679.00
12/ P.No. 105/13.92.2)
13.93 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
Internal Plumbing - for concealed fitting. (PWD SR 2011-12/ P.No. 105/13.93)

13.93.1 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 181.00
Internal Plumbing - for concealed fitting.(20mm pipe outer dia (3 layer) ). (PWD
SR 2011-12/ P.No. 105/13.93.1)

13.93.2 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 236.00
Internal Plumbing - for concealed fitting.(25 mm pipe outer dia (3 layer) ). (PWD
SR 2011-12/ P.No. 105/13.93.2)

13.93.3 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 287.00
Internal Plumbing - for concealed fitting.(32 mm pipe outer dia (3 layer) ). (PWD
SR 2011-12/ P.No. 105/13.93.3)

13.94 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
Internal Plumbing - for exposed on wall. (PWD SR 2011-12/ P.No. 106/13.94)

13.94.1 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 124.00
Internal Plumbing - for exposed on wall.{ 20mm pipe outer dia (3 layer ) } (PWD
SR 2011-12/ P.No. 106/13.94.1)

13.94.2 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
m 158.00
Internal Plumbing - for exposed on wall.{ 25 mm pipe outer dia (3 layer ) } (PWD
SR 2011-12/ P.No. 106/13.94.2)

13.94.3 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
Internal Plumbing - for exposed on wall.{ 32 mm pipe outer dia (3 layer ) } (PWD m 214.00
SR 2011-12/ P.No. 106/13.94.3)

13.94.4 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 302.00
Internal Plumbing - for exposed on wall.{ 40 mm pipe outer dia (3 layer ) } (PWD
SR 2011-12/ P.No. 106/13.94.4)
13.94.5 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
m 466.00
Internal Plumbing - for exposed on wall. { 50 mm pipe outer dia (3 layer ) }
(PWD SR 2011-12/ P.No. 106/13.94.5)

13.95 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
External Plumbing. (PWD SR 2011-12/ P.No. 106/13.95)

13.95.1 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
External Plumbing. { 20 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No. m 114.00
106/13.95.1)

13.95.2 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
External Plumbing. { 25 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No. m 154.00
106/13.95.2)

13.95.3 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
m 196.00
External Plumbing. { 32 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No.
106/13.95.3)

13.95.4 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 276.00
External Plumbing. { 40 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No.
106/13.95.4)

13.95.5 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 501.00
External Plumbing. { 50 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No.
106/13.95.5)

13.95.6 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
External Plumbing. { 63 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No. m 643.00
106/13.95.6)

13.95.7 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 799.00
External Plumbing. { 75 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No.
106/13.95.7)
13.95.8 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 1212.00
External Plumbing. { 90 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ P.No.
106/13.95.8)

13.95.9 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls. m 1287.00
External Plumbing. { 110 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/
P.No. 106/13.95.9)

13.95.10 Providing and fixing concealed UV stablished and antimicrobial fusion 3 layer
PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings including
brass threaded polypropelene random fittings including chasing the walls.
External Plumbing. { 160 mm pipe outer dia (3 layer ) } (PWD SR 2011-12/ m 2411.00
P.No. 106/13.95.10)
FLOORING
14.1 KSRB 14.1: Providing and laying flooring with burnt stone slabs 10 cms
thick, rough chistle dressed on sand bed 7.5 cms to 8 cms thick and
pointed with cement mortar 1:3, including cost of materials, labour, curing Sqm 619.00
complete as per specifications. Specification No. KBS 14.26 (PWD
SR2011-12/P.No. 108/14.1)

14.2 KSRB 14.2: Providing and laying flooring with burnt stone slabs 10 cms
thick, rough chistle dressed on cement mortar bed 1:6, 25mm thick, and
pointed with cement mortar 1:3, including cost of materials, labour, curing Sqm 620.00
complete as per specifications. Specification No. KBS 14.26 (PWD
SR2011-12/P.No.108/14.2)

14.3 KSRB 14.3: Providing and laying flooring and steps machine cut granite
slabs 40mm thick on cement mortar bed 1:6, 25mm thick, and pointed
with cement mortar bed 1:3 over existing cement concrete bed, including
cost of materials, labour, curing complete as per specifications. Sqm 1611.00
Specification No. KBS 14.26 (PWD SR2011-12/P.No. 108/14.3)

14.4 KSRB 14.4: Providing and laying flooring and steps fine dressed granite
stone slabs 40mm thick on cement mortar bed 1:6, 25mm thick, and
pointed with cement mortar bed 1:3 over existing cement concrete bed,
including cost of materials, labour, curing complete as per specifications. Sqm 1964.00
Specification No. KBS 14.26 (PWD SR2011-12/P.No. 108/14.4)

14.5 KSRB 14.5: Providing and laying flooring and steps fine machine polished
granite stone slabs black / natural/ green / pink colour 20mm thick on
cement mortar bed 1:6, 20mm thick, and joints finished with cement mortar
bed 1:3 over existing cement concrete bed, including cost of materials, Sqm 898.00
labour, curing complete as per specifications. Specification No. KBS 14.26
(PWD SR2011-12/P.No. 108/14.5)

14.6 KSRB 14-6.1: Providing and laying heavy duty cobble stones 60mm
thick interlock pavers, using cement and course sand for manufacture of
blocks of approved size, shape and colour with a minimum compressive
strength of 281 kg per sqm over 50mm thick sand bed (average thickness)
and compacting with plate vibrator having 3 tons compaction force thereby
Sqm 654.00
forcing part of sand underneath to come up in between joints, final
compaction of pavar surface joints into its final level, including cost of
materials, labour and HOM of machineries complete as per specifications.
(PWD SR2011-12/P.No. 108/14.6)
14.7 KSRB 14-6.2: Providing and laying heavy duty cobble stones 75mm
thick interlock pavers, using cement and course sand for manufacture of
blocks of approved size, shape and colour with a minimum compressive
strength of 281 kg per sqm over 50mm thick sand bed (average thickness)
and compacting with plate vibrator having 3 tons compaction force thereby Sqm 719.00
forcing part of sand underneath to come up in between joints, final
compaction of pavar surface joints into its final level, including cost of
materials, labour and HOM of machineries complete as per specifications.
(PWD SR2011-12/P.No.108/14.7)

14.8 KSRB 14-7.1: Providing and laying flooring with 1:2:4 cement concrete, 40
mm thick Sqm 150.09 using broken granite metal of 20 mm and down size
laid to line and level in one layer and finish with a floating coat of neat
cement, including cost of materials, labour, curing complete as per Sqm 241.00
specifications. Specification No. KBS 14.3 (PWD SR2011-
12/P.No.108/14.8)

14.9 KSRB 14-7.2: Providing and laying red oxide flooring 40mm thick, with an
under layer of 30mm thick 1:2:4 cement concrete, using broken granite
metal of 12.5mm nominal size and top layer of 10mm thick plaster with 1:3
cement mortar mixed with red of oxide (using 3.5 kg of red oxide per 50
kg of cement) finished with floating coat of neat cement mixed with red Sqm 430.00
oxide (mix of same proportion), including cost of materials, labour, curing,
complete as per specifications. Specification No.KBS 14.3 (PWD SR2011-
12/P.No.109/14.9)

14.10 KSRB 14-7.3: Providing and laying flooring 40mm thick, with an imder
layer of 30mm thick 1:2:4 cement concrete, using broken granite metal of
12.5mm nominal size and top layer of 10mm thick plaster with cement
mortar 1:3, finished with floating cost of neal cement including cost of Sqm 375.00
materials, labour, curing, complete as per specifications. Specification
No.KBS 14.3 (PWD SR2011-12/P.No. 109/14.10)

14.11 KSRB 14-7.4: Extra for making chequers of approved pattern on cement
concrete floor, steps, landings, pavements, including cost of labour
complete as per specifications. (PWD SR2011-12/P.No. 109/14.11) Sqm 16.00

14.12 KSRB 14-8.1: Providing and laying linolium covering to floors plain or
coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub
floor stretching, cutting and fixing complete, including cost of materials, Sqm 380.00
labour, complete as per specifications. Specification No. KBS 14.37.7
(PWD SR2011-12/P.No. 109/14.12)
14.13 KSRB 14-9.1: Providing and laying 1:2:4 cement concrete flooring 50 mm
thick with metallic concrete hardner toping, under layer of 35 mm thick
1:2:4 cement concrete using broken granite metal of 20mm and down size,
and top layer 50mm thick of metallic cement hardner consisting of mix 1:2
(1 cement hardner mix : 2 granite metal 10mm nominal size) by volume,
with which metallic hardening compound of approved quality mix in the
ratio of 4:1 (4 part of cement and 1 part of metallic floor hardening Sqm 1583.00
compound of approved quality by wt), including finishing cost of materials,
labour, curing complete as per specification.Specification No. KBS 14.4
(PWD SR2011-12/P.No. 109/14.13)

14.14 KSRB 14-9.2: Providing and laying 1:2:4 cement concrete flooring 60mm
with metallic concrete hardner toping, under layer of 45 mm thick 1:2:4
cement concrete using broken granite metal of 20mm and down size, and
top layer 15mm thick of metallic cement hardner consisting of mix 1:2 (1
cement hardner mix : 2 granite metal 10mm nominal size) by volume, with
metallic hardening compound of approved quality mix in the ratio of 4:1 (4
Sqm 1646.00
part of cement = 1 part of metallic floor hardening compound of approved
quality by wt), including finishing cost of materials, labour, curing complete
as per specification.Specification No. KBS 14.4 (PWD SR2011-12/P.No.
109/14.14)

14.15 KSRB 14-10.1: Flooring with 25mm to 40mm thick polished tandur blue
stone slabs using cement mortar 1:6, 25mm thick over existing cement
concrete bed of top of roof laid to line and level and joined with cement
slurry mixed with pigment to match the shade of the slab, including cost of Sqm 755.00
materials, labour, curing, polishing complete as per specifications. (PWD
SR2011-12/P.No. 109/14.15)

14.16 KSRB 14-10.2: Flooring with 25mm to 40mm thick polished shahabad
slabs using cement mortar 1:6, 25mm thick over existing cement concrete
bed of top of roof laid to line and level and joined with cement slurry mixed
with pigment to match the shade of the slab, including cost of materials, Sqm 863.00
labour, curing, polishing complete as per specifications. (PWD SR2011-
12/P.No.110/14.16)

14.17 KSRB 14-10.3: Providing flooring with 25mm to 40mm thick polished
Cadappa slabs using cement mortar 1:6, 25mm thick over existing
cement concrete bed of top of roof laid to line and level and joined with
cement slurry mixed with pigment to match the shade of the slab, including Sqm 791.00
cost of materials, labour, curing, polishing complete as per specifications.
(PWD SR2011-12/P.No. 110/14.17)
14.18 KSRB 14-11.1: Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with dark shade pigment
with ordinary cement in top layer only using while, black, chacolate, yellow
or baroda green marble chips of size from 7 to 10 nominal size laid in
cement marble powder mix 3:1 (3 cement : 1 marble powder by weight) in
Sqm 795.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) curing polishing oxalic acid wash, wax polish, including cost of
materials, labour, curing, polishing complete as per specifications.
Specification No. KBS 14.8 (PWD SR2011-12/P.No. 110/14.18)

14.19 KSRB 14-11.2: Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with light shade pigment
with white cement in top layer only using while, black, chacolate, yellow or
baroda green marble chips of size from 7 to 10 nominal size laid in cement
marble stone mixed 3:1 (3 cement : 1 marble powder by weight) in Sqm 890.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) curing polishing oxalic acid wash, wax polish, including cost of
materials, labour, complete as per specifications. Specification No. KBS
14.8 (PWD SR2011-12/P.No. 110/14.19)

14.20 KSRB 14-11.3 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with medium shade
pigment with approximately 50% white cement and 50% ordinary cement
in top layer only using white, black, chacolate, yellow or baroda green
marble chips of size from 7 to 10 nominal size laid in cement marble stone
mixed 3:1 (3 cement : 1 marble powder by weight) in proportion of 4:7 (4 Sqm 819.00
cement marble powder mix : 7 marble chips by volume) curing polishing
oxalic acid wash, wax polish, including cost of materials, labour, complete
as per specifications. Specification No. KBS 14.8 (PWD SR2011-12/P.No.
110/14.20)

14.21 KSRB 14-11.4 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete 1:2:4 with stone aggregate
12mm and down size, and top layer 12mm thick with white cement without
any pigment in top layer only using white, black, chacolate, yellow or
baroda green marble chips of size from 7 to 10 nominal size laid in cement
marble stone mixed 3:1 (3 cement : 1 marble powder by weight) in Sqm 817.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) curing polishing oxalic acid wash, wax polish, including cost of
materials, labour, complete as per specifications. Specification No. KBS
14.8 (PWD SR2011-12/P.No. 111/14.21)
14.22 KSRB 14-11.5 : Extra for providing and fixing aluminium strips 40 mm wide
and 1.5 mm thick painted with a protective coat of bitumen for joints of
mosaic floors, including cost of materials, labour, curing, complete as per m 28.00
specification (PWD SR2011-12/P.No.111/14.22)

14.23 KSRB 14-11.6 : Extra for providing and fixing glass strips 40 mm wide and
4mm thick for joints of mosaic floors, including cost of materials, labour,
curing, complete as per specifications. (PWD SR2011-12/P.No. 111/14.23) m 35.00

14.24 KSRB 14-12.1: Providing mosaic tiles flooring with precast gret colour
mosaic tiles 20mm thick using marble chips of approved colour 7 to 10
nominal size laid in floors and landings on a bed of 25mm thick cement
mortar 1:6, mix, jointed with neat cement slurry mix with pigment to match
the shade of tiles curing, rubbing, polishing, oxalic acid wash, wax polish,
Sqm 618.00
including cost of materials, labour, HOM of machinary complete as per
specifications. Specification No. KBS 14.11 (PWD SR2011-12/P.No.
111/14.24)

14.25 KSRB 14-12.2: Providing mosaic tiles flooring with precast light shade
pigment with white cement mosaic tiles 20mm thick using marble chips of
approved colour 7 to 10 nominal size laid in floors and landings on a bed
of 25mm thick cement mortar 1:6, mix, jointed with neat cement slurry mix
with pigment to match the shade of tiles curing, rubbing, polishing, oxalic
Sqm 682.00
acid wash, wax polish, including cost of materials, labour, HOM of
machinary complete as per specifications. Specification No. KBS 14.11
(PWD SR2011-12/P.No. 111/14.25)

14.26 KSRB 14-12.3 : Providing mosaic tiles flooring with precast medium shade
pigment using 50% white cement and 50% ordinary cement mosaic tiles
20mm thick using marble chips of approved colour 7 to 10 nominal size
laid in floors and landings on a bed of 25mm thick average thickness of
cement mortar 1:6, mix, jointed with neat cement slurry mix with pigment
to match the shade of tiles curing, rubbing, polishing, oxalic acid wash, Sqm 498.00
wax polish, including cost of materials, labour, HOM of machinary
complete as per specifications. (PWD SR2011-12/P.No. 111/14.26)

14.27 KSRB 14-12.4 : Providing mosaic tiles flooring with white precast cement
mosaic tiles 20mm thick using marble chips of 7 to 10 nominal size laid in
floors and landings on a bed of 25 mm thick average thickness of cement
mortar 1:6, mix, jointed with neat cement slurry mix with pigment to match
the shade of tiles, curing, rubbing, polishing, oxalic acid wash, wax polish, Sqm 620.00
including cost of materials, labour, HOM of machinary complete as per
specifications. (PWD SR2011-12/P.No.112/14.27)
14.28 KSRB 14-13.1: Providing precast chequered mosaic tiles dark shade using
ordinary grey cement for steps and flooring, with precast 20mm thick,
using marble chips of 7 to 10 nominal size laid in floors, steps and landings
on a bed of 12mm thick cement mortar 1:3 mix, and jointed with neat
cement slurry mixed with pigment to match the shade of tiles, curing,
rubbing, polidhinh, oxslic acid wash, wax polish, including cost of Sqm 804.00
materials, labour complete as per specifications. (PWD SR2011-12/P.No.
112/14.28)

14.29 KSRB 14-13.2: Providing precast chequered mosaic tiles light shade using
white cement for steps and flooring, 20mm thick, using marble chips of 7 to
10 nominal size laid in floors, steps and landings on a bed of 12mm thick
cement mortar 1:3 mix, and jointed with neat cement slurry mixed with
pigment to match the shade of tiles curing, rubbing, polishing, oxalic acid Sqm 903.00
wash, wax polish, including cost of materials, labour, complete as per
specifications. Specification No. KBS 14.13, 14.14 (PWD SR2011-
12/P.No. 112/14.29)

14.30 KSRB 14-13.3: Providing precast chequered mosaic tiles medium shade
pigment using 50% white cement and 50% ordinary cement for steps and
flooring 20mm thick using marble chips of 7 to 10 nominal size laid on a
bed of 12mm thick cement mortar 1:3 mix, and jointed with neat cement
slurry mixed with pigment to match the shade of tiles curing, rubbing,
polishing, oxalic acid wash, wax polish, including cost of materials, labour, Sqm 868.00
complete as per specifications. Specification No. KBS 14.13, 14.14 (PWD
SR2011-12/P.No. 112/14.30)

14.31 KSRB 14-13.4: Providing precast chequered mosaic tiles white colour for
steps and Sqm 530.78 flooring, 20mm thick, using marble chips of 7 to 10
nominal size laid on a bed of 12mm thick cement mortar 1:3 mix, and
jointed with neat cement slurry mixed with pigment to match the shade of
tiles rubbing, polishing, oxalic acid wash, wax polish, including cost of Sqm 955.00
materials, labour, curing, complete as per specifications. Specification No.
KBS 14.13, 14.14 (PWD SR2011-12/P.No. 112/14.31)

14.32 KSRB 14-14.1: Providing white glazed tiles of sizes 10mm thick for
flooring, treads of steps and landings, laid on a bed of 12mm thick, cement
mortar 1:3 mix, finished with flush pointing using white cement, including Sqm 775.00
cost of materials, labour, curing, complete as per specifications. (PWD
SR2011-12/P.No. 112/14.32)

14.33 KSRB 14-14.2: Providing colour glazed tiles of size 15 cms x 15 cms
10mm thick for flooring, treads of steps and landings laid on a bed of
12mm thick, cement mortar 1:3 mix, flush pointing using white cement with
matching colour pigment, including cost of materials, labour, curing, Sqm 802.00
complete as per specifications. Specification No. KBS 14.15.2 (PWD
SR2011-12/P.No. 113/14.33)
14.34 KSRB 14-14.3: Providing white glazed tiles of size 15 cms x 15 cms 6mm
thick for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing using white cement with matching
colour pigment, including cost of materials, labour, curing, complete as per Sqm 718.00
specifications. Specification No. KBS 14.15.1 (PWD SR2011-12/P.No.
113/14.34)

14.35 KSRB 14.14.-4: Providing colour glazed tiles of size 15 cms x 15 cms 6mm
thick for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing using white cement with matching
colour pigment, including cost of materials, labour, curing, complete as per Sqm 787.00
specifications. Specification No. KBS 14.15.2 (PWD SR2011-12/P.No.
113/14.35)

14.36 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 113/14.36.1)

14.36.1 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per Sqm 745.00
specifications. for Ceramic Tiles of size 15 x 15 cms (PWD SR2011-
12/P.No. 92/14.36.1)

14.36.2 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per Sqm 813.00
specifications. for Ceramic Tiles of size 30 x 30 cms (PWD SR2011-
12/P.No. 113/14.36.2)

14.36.3 KSRB 14-14.5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm thick,
cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing, complete as per Sqm 995.00
specifications. for Ceramic Tiles of size 400 x 400 mm on a bed of 20 mm
thick (PWD SR2011-12/P.No. 113/14.36.3)

14.37 KSRB 14-15.1: Providing marble slab flooring 20mm thick with edges of
slab machine cut, for flooring, treads of steps and landings laid on a bed of
25mm thick cement mortar 1:6, mix, to line and level, jointed with cement
slurry curing, rubbing, polishing complete finishling with flush pointing
using white cement, including cost of materials, HOM of machineries,
labour, curing, complete as per specifications. Note : While preparing Sqm 1670.00
analysis the quality of marble slab should be clearly noted namely white
marble, adanga marble, makrana etc., and also size of slab should be
noted clearly. Specification No. KBS 14.18 (PWD SR2011-12/P.No.
113/14.37)
14.38 KSRB 14-16.1 : Providing skirting upto 30 cms. height with cement mortar
1:3 finished with a floating coat of neat cement including rounding off
junctions floor, overall 15mm thick including cost of materials, labour, Sqm 195.00
complete as per specifications. Specification No. KBS 14.5 (PWD SR2011-
12/P.No. 113/14.38)

14.39 KSRB 14-16.2 : Providing red oxide skirting upto 30 cms. height with
cement mortar 1:3 including rounding off junctions with floor, finished
overall 15mm thick, top portion 5mm thickmixed with red oxide and a
floating coat of neat cement using 3.5kg of red oxide of iron per 50 kg of Sqm 218.00
cement including cost of materials, labour, complete as per specifications.
Specification No. KBS 14.5 (PWD SR2011-12/P.No. 113/14.39)

14.40 KSRB 14-17.1 : Providing skirting, dado, rises of steps with white glazed
tiles20 X 20cms 6mm thick on 10mm thick cement plaster 1:3 and
jointed with white cement slurry over rough plaster surface (excluding cost
of rough plastered surface which should be measured and paid separately) Sqm 751.00
using glazed tiles of approved make and size including cost of materials,
labour, complete as per specifications. Specification No. KBS 14.16, 14.17
(PWD SR2011-12/P.No. 114/14.40)

14.41 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed
tiles 20 X 20 cms 6mm thick on 10mm thick cement plaster 1:3 and jointed
with white cement slurry over rough plaster surface (excluding cost of
rough plastered surface which should be measured and paid separately)
using glazed tiles of approved make and size including cost of materials,
labour, complete as per specifications. Specification No. KBS 14.16, 17.17
(PWD SR2011-12/P.No. 114/14.41)

14.41.1 Colour glazed tiles 15x15 cms 6mm thick. (PWD SR2011-12/P.No.
Sqm 843.00
114/14.41.1)

14.41.2 Colour glazed tiles 30x60 cms 6mm thick with border of size 30 x 10 cms.
Sqm 1281.00
(PWD SR2011-12/P.No. 114/14.41.2)

14.41.3 Colour glazed tiles 30x45 cms 6mmm thick with border of size 30x10 cms
Sqm 1162.00
(PWD SR2011-12/P.No. 114/14.41.3)

14.42 KSRB 14-18.1 : Providing skirting, dado, rises of steps with marble slabs
not exceeding 30 cms. height on 10 cms. thick cement mortar 1:3 and
jointed with white cement slurry over rough plaster surface (excluding cost
of rough plastered which should be measured and paid separately) using
marble slab with machine cut edges upto 25 cms. thick including cost of Sqm 1782.00
materials, labour, complete as per specifications. Specification No. KBS
14.19 (PWD SR2011-12/P.No. 114/14.42)
14.43 Providing and fixing Special make glazed Vitrified tiles (Granomite finish)
of approved make, quality and colour of size 600 x 600x10mm thick fixed
on existing flooring with a special roffe adhesive for flooring and skirting
etc., complete including providing spears at required interval and removing Sqm 1150.00
stains etc., complete. (PWD SR2011-12/P.No. 114/14.43)

14.44 Providing flooring with 60 cms x 60cms. size Vitrified glazed tiles of
approved quality & make, fixed on top of existing flooring fixed with
suitable adhesive, including cutting the tiles to the required size and fixing Sqm 1079.00
etc., complete. (PWD SR2011-12/P.No. 114/14.44)

14.45 Providing vitrified tiles 60 cms x 60 cms of approved make, shade and size
for flooring laid on a bed of 12 mm thick cement mortar 1:3 mix, flush
pointing with white cement using colour pigment, including cost of
Sqm 982.00
materials, labour, curing complete as per specifications. (PWD SR2011-
12/P.No. 114/14.45)

14.46 Providing and Laying pattern flooring for staircase treads and risers using
the combiantion of 20mm thick ruby red granite @ 66%, 20mm thick grey
granite @ 20%, 20 mm thick Shiva gold granite 7%, 20mm thick black
granite 7%. The granite meterials are laid on existing bed of CM 1:320 mm
thick pointed with colour pigment, including full rounding for nosing, Sqm 5804.00
flaming the ruby red granite for 50mm wide curing etc., complete (PWD
SR2011-12/P.No. 114/14.46)

14.47 Providing and Laying flooring using pre polished 19 mm thick water
cut/gang saw Granite slab over existing cement concrete bed in CM 1:4
average 20mm thick pointed with white cement/colour pigment etc.,
complete. (PWD SR2011-12/P.No. 115/14.47)

14.47.1 Providing and Laying flooring using pre polished 19 mm thick water
cut/gang saw Granite slab over existing cement concrete bed in CM 1:4
average 20mm thick pointed with white cement/colour pigment etc.,
complete. for grey granite (PWD SR2011-12/P.No. 115/14.47.1) Sqm 1614.00

14.47.2 Providing and Laying flooring using pre polished 19 mm thick water
cut/gang saw Granite slab over existing cement concrete bed in CM 1:4
average 20mm thick pointed with white cement/colour pigment etc., Sqm 1740.00
complete. for black granite (PWD SR2011-12/P.No. 115/14.47.2)

14.47.3 -do- using 10mm thick grey granite tiles. (PWD SR2011-12/P.No.
115/14.47.3) Sqm 1362.00
14.47.4 -do- using 10mm thick black granite tiles. (PWD SR2011-12/P.No.
115/14.47.4) Sqm 1425.00

14.47.5 -do- using Raw silk granite. (PWD SR2011-12/P.No. 115/14.47.5) Sqm 2954.00

14.47.6 -do- using Hassan green granite. (PWD SR2011-12/P.No. 115/14.47.6) Sqm 2118.00

14.48 Providing and Laying flooring for corridors/lobbies using combination of pre
polished 19mm thick water cut/gang saw Grey Granit, black granite, and
strips of 50mm wide pre flamed grey granite using pre polished grey
granite 19mm thick 76% pre polished black granite 19mm thick @ 2% and
preflamed 19mm thick grey granite @ 22% over existing cement concrete
bed in CM 1:4 average 20mm thick pointed with white cement/colour
pigment etc., complete (PWD SR2011-12/P.No. 115-94/14.48)

14.48.1 -do- using 19mm thick granite. (PWD SR2011-12/P.No. 115-94/14.48.1)


Sqm 2878.00

14.48.2 -do- using 10mm thick granite. (PWD SR2011-12/P.No. 115-94/14.48.2)


Sqm 2871.00

14.49 Providing and fixing of wall cladding using 20mm thick gang saw water cut
Shiva gold granite, grey granite in CM 1:3 proportion cut to required shape,
pattern with paper joints, finished with cement mortal using white cement
and colour pigments to match the colour of slab making through jointing Sqm 3173.00
with sealant, making holes 25mm x 12mm grooves in joints including
curing etc., complete (PWD SR2011-12/P.No. 115/14.49)

14.50 Providing and fixing skirting of 300 mm high using prepolished water
cut/gang saw of 19mm thick grey granite 0.5mm wide chamfered width
and depth and fixing in CM 1:4 of 20mm thick after chipping the walls etc. m 594.00
complete. (PWD SR2011-12/P.No. 115/14.50)

14.51 Providing and laying Hassan Green granite flooring for staircase, treads
and rises using pre polished 20 mm thick water cut green Granite slab laid
over existing cement concrete bed in CM 1:3, average 20mm thick includig
full rounding fornosing, cutting 3 line grooves not more than 2 mm wide for Sqm 3191.00
antiskidding, curing etc., complete (PWD SR2011-12/P.No. 115/14.51)

14.52 Providing and laying plat form using prepolished, water cut/ gang saw
40mm thick telephonic Black Granite. Laid existing vertical - supports and
fixing in CM 1:3 propotion. Including cutting to required shape, pattern with
paper joints, Including full rounding for nosing, finished with cement
mortar, pointed with colour pigments to match the colour of slab making Sqm 2231.00
through jointing with sealent, making holes 25mm x 12mm grooves in
joints including curing. (PWD SR2011-12/P.No. 115/14.52)
14.53 Providing full nosing for 40mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification. (PWD SR2011- m 363.00
12/P.No. 116/14.53)

14.54 Providing half nosing for 40mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification. (PWD SR2011- m 242.00
12/P.No. 116/14.54)

14.55 Providing full nosing for 20mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification. (PWD SR2011- m 182.00
12/P.No. 116/14.55)

14.56 Providing half nosing for 20mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification. (PWD SR2011- m 121.00
12/P.No. 116/14.56)

14.57 Providing and fixing 40mm thick sadarahalli grey flamed granite slab for
bath areas in Bathrooms over a bed of 25mm thick CM 1:6 and fixing Sqm 1476.00
granite slab with CM 1:3. (PWD SR2011-12/P.No. 116/14.57)

14.58 Providing and fixing granite flooring granite in combination of 19mm thick
(AVG) gang saw water cut LAKARED granite with 86% and with 14% of 19
mm thick (avg) Black granite in CM 1:4 propotion with a coat of rough
plastering using CM 1:4, cut to required shape, pattern with paper joints,
finished with cement mortar using white cement and colour pigments to
match the colour of slab making through jointing with sealent, grooves in Sqm 4060.00
joints including cost of curing etc., complete including cost and
conveyance of all materials, labour for all items of work, HOM of
equipment etc., complete as per specification. (PWD SR2011-12/P.No.
116/14.58)

14.59 Providing and fixing 20mm thick gang saw water cut telephonic black
granite in CM 1:4 propotion with a coat of rough plastering using CM 1:4
cut to required shape, pattern with paper joints, finished with cement
mortar using white cement and colour pigments to match the colour of slab
making through jointing with sealent, grooves in joints including cost of Sqm 2392.00
curing etc., complete including cost and conveyance of all materials,
labour for all items of work, HOM of equipment etc., complete as per
specification. (PWD SR2011-12/P.No. 116/14.59)
14.60 Providing and fixing 20mm thick gang saw water cut LAKARED black
granite in CM 1:4 propotion with a coat of rough plastering using CM 1:4
cut to required shape, pattern with paper joints, finished with cement
mortar using white cement and colour pigments to match the colour of slab
making through jointing with sealent, grooves in joints including cost of Sqm 4045.00
curing etc., complete including cost and conveyance of all materials,
labour for all items of work, HOM of equipment etc., complete as per
specification. (PWD SR2011-12/P.No. 116/14.60)

14.61 Providing and fixing 20mm thick gang saw water cut sadarhalli grey granite
in CM 1:4 proportion, cut to required shape, pattern with paper joints,
finished with cement mortar using white cement and colour pigments to
match the colour of slab making through jointing with sealent, grooves in Sqm 1686.00
joints including cost of curing.(PWD SR2011-12/P.No. 116/14.61)

14.62 Providing and laying/ fixing cement base, precast, pre polished cement
concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles
for flooring, treads of steps, and landing, laid on a bed of 12mm thick
cement mortar 1:3 mix finished with flush pointing using white cement,
Sqm 946.00
including cost of materials, including cutting, griding the edge to half/full
round wherever required, labour. curing complete as per specification.
(PWD SR2011-12/P.No. 117/14.62)

14.63 Providing and fixing Ceramic tiles of size 400x400mm for flooring, threads,
steps and landing, laid on a bed of 20mm thick cement mortar 1:3 mix
flush pointing with white cement mixed with matching colour pigment
including curing, cleaning etc., complete. The work includes cost of all
Sqm 919.00
materials, labour charges for all items of work. hire charges for equipment
etc., complete as per specification. (PWD SR2011-12/P.No. 117/14.63)

14.64 Providing and fixing Colour glazed tiles of size 300x600mm for Walls with
borders of size 300x100mm, set in cement mortar 1:3 and pointed with
white cement mixed with matching colour pigment with necessary curing,
cleaning etc., complete. The work includes cost of all materials, labour Sqm 1015.00
charges for all items of work. hire charges for equipment etc., complete as
per specification. (PWD SR2011-12/P.No. 117/14.64)

14.65 Providing and fixing Colour glazed tiles of size 300x450mm for Walls with
borders of size 300x100mm, set in cement mortar 1:3 and pointed with
white cement mixed with matching colour pigment with necessary curing,
cleaning etc., complete. The work includes cost of all materials, labour Sqm 1226.00
charges for all items of work. hire charges for equipment etc., complete as
per specification. (PWD SR2011-12/P.No. 117/14.65)
14.66 Providing and laying heavy duty cobble stones 80mm thick interlock
pavers, using cement and course sand for manufacture of block of
approved size, shape and colour with a minimum compressive strength of
281 kg per sqm over 50mm thick sand bed ( average thickness ) and
compacting with plate vibrator having 3 tons compaction force there by
forcing part of sand underneath to come up in between joints, final
compaction of paver surface joints into its final level, including cost of
materials, labour and HOM of machinaries complete as per specification.
(PWD SR2011-12/P.No. 116/14.66)

14.66.1 Providing and laying heavy duty cobble stones 65mm thick interlock
pavers, using cement and course sand for manufacture of block of
approved size, shape and colour with a minimum compressive strength of
281 kg per sqm over 50mm thick sand bed ( average thickness ) and
compacting with plate vibrator having 3 tons compaction force there by
Sqm 668.00
forcing part of sand underneath to come up in between joints, final
compaction of paver surface joints into its final level, including cost of
materials, labour and HOM of machinaries complete as per specification.
(PWD SR2011-12/P.No. 117/14.66.1)

14.66.2 Providing and laying heavy duty cobble stones 80mm thick interlock
pavers, using cement and course sand for manufacture of block of
approved size, shape and colour with a minimum compressive strength of
281 kg per sqm over 50mm thick sand bed ( average thickness ) and
compacting with plate vibrator having 3 tons compaction force there by
Sqm 834.00
forcing part of sand underneath to come up in between joints, final
compaction of paver surface joints into its final level, including cost of
materials, labour and HOM of machinaries complete as per specification.
(PWD SR2011-12/P.No. 117/14.66.2)

14.67 providing and fixing of wall cladding using 20mm thicl gang saw watercut
grey granite in CM 1:3 proportion cut to required shape, patter with papers
joints, finished with cement mortal using white cement and colour pigments
to match the colour of slab making through jainting with sealent, making Sqm 2547.00
holes 25mmx12mm grooves in joints including curing etc., complete. (PWD
SR2011-12/P.No. 117/14.67)
FINISHING WORK / PLASTERING
15.1 KSRB 15.1.1 : Providing flush pointing to square rubble, course or
uncoursed stone masonry with cement mortar 1:3, 20mm deep, after
raking joints to depth of 20mm nicely lining, including cost of materials, Sqm 69.50
labour, curing, complete as per specifications. (PWD SR2011-12/P.No.
119/15.1)

15.2 KSRB 15.1.2 : Providing flush pointing to square rubble, course or


uncoursed stone masonry with cement mortar 1:4, 20mm deep, after
raking joints to depth of 20mm nicely lining, including cost of materials, Sqm 67.00
labour, curing, complete as per specifications. (PWD SR2011-12/P.No.
119/15.2)

15.3 KSRB 15.1.3 : Providing ruled pointing to coursed stone masonry with
cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm
nicely lining, including cost of materials, labour, curing, complete as per Sqm 69.50
specifications. (PWD SR2011-12/P.No. 119/15.3)

15.4 KSRB 15.1.4 : Providing ruled pointing to coursed stone masonry with
cement mortar 1:4, 20mm deep, after raking joints to depth of 20mm
nicely lining, including cost of materials, labour, curing, complete as per Sqm 67.50
specifications. (PWD SR2011-12/P.No. 119/15.4)

15.5 KSRB 15.1.5 : Providing raised and cut pointing to coursed stone
masonry with cement mortar 1:3, 20mm, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing, complete as Sqm 102.00
per specifications. (PWD SR2011-12/P.No. 119/15.5)

15.6 KSRB 15.1.6 : Providing raised and cut pointing to coursed stone
masonry with cement mortar 1:4, 20mm, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing, complete as Sqm 98.50
per specifications. (PWD SR2011-12/P.No. 119/15.6)

15.7 KSRB 15.2.1 : Providing flush pointing to stone slab pavements, with
cement mortar 1:3, after ranking joints, nicely lining, including cost of
materials, labour, curing, complete as per specifications. (PWD SR2011- Sqm 24.00
12/P.No. 119/15.7)

15.8 KSRB 15.2.2 : Providing ruled pointing to stone slab pavements with
cement mortar 1:3, 20mm deep, after raking joints, including cost of
materials, labour, curing, complete as per specifications. (PWD SR2011- Sqm 25.00
12/P.No. 119/15.8)

15.9 KSRB 15.3.1 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:3 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing
scaffolding, including cost of materials, labour, curing, complete as per Sqm 129.00
specifications. (PWD SR2011-12/P.No. 119/15.9)
15.10 KSRB 15.3.2 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:4 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing
scaffolding, including cost of materials, labour, curing, complete as per Sqm 117.00
specifications. (PWD SR2011-12/P.No. 119/15.10)

15.11 KSRB 15.3.3 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:6 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing
scaffolding, including cost of materials, labour, curing, complete as per Sqm 105.00
specifications. (PWD SR2011-12/P.No. 119/15.11)

15.12 KSRB 15.3.4 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:3 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing
scaffolding, including cost of materials, labour, curing, complete as per Sqm 147.00
specifications. (PWD SR2011-12/P.No. 119/15.12)

15.13 KSRB 15.3.5 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:4 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing
scaffolding, including cost of materials, labour, curing, complete as per Sqm 132.00
specifications. (PWD SR2011-12/P.No. 119/15.13)

15.14 KSRB 15.3.6 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:6 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 116.00
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 119/15.14)

15.15 KSRB 15.3.7 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:3 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 175.00
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 119/15.15)

15.16 KSRB 15.3.8 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:4 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 156.00
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 120/15.16)

15.17 KSRB 15.3.9 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:6 to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 138.00
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 120/15.17)
15.18 KSRB 15.3.10 : Providing 20mm thick cement plaster in single coat with
cement mortar 1:3 to stone masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 185.50
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 120/15.18)

15.19 KSRB 15.3.11 : Providing 20 mm thick cement plaster in single coat with
cement mortar 1:4 to stone masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 165.00
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 120/15.19)

15.20 KSRB 15.3.12 : Providing 20 mm thick cement plaster in single coat with
cement mortar 1:6 to stone masonry including rounding off corners
wherever required smooth rendering, : Providing and removing Sqm 145.00
scaffolding, including cost of materials, labour, curing, complete as per
specifications. (PWD SR2011-12/P.No. 120/15.20)

15.21 KSRB 15.3.13 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:3 to ceiling including rounding off corners wherever
required smooth rendering, : Providing and removing scaffolding, including Sqm 138.00
cost of materials, labour, curing, complete as per specifications. (PWD
SR2011-12/P.No. 120/15.21)

15.22 KSRB 15.3.14 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:4 to ceiling including rounding off corners wherever
required smooth rendering, : Providing and removing scaffolding, including Sqm 126.00
cost of materials, labour, curing, complete as per specifications. (PWD
SR2011-12/P.No. 120/15.22)

15.23 KSRB 15.4.1 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials Sqm 6.50
complete as per specification (PWD SR2011-12/P.No. 120/15.23)

15.24 KSRB 15.4.2 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 12mm thick cost of materials Sqm 5.00
complete as per specification (PWD SR2011-12/P.No. 120/15.24)

15.25 KSRB 15.4.3 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 15mm thick cost of materials Sqm 6.00
complete as per specification (PWD SR2011-12/P.No. 120/15.25)
15.26 KSRB 15.4.4 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 18mm thick cost of materials
Sqm 7.50
complete as per specification (PWD SR2011-12/P.No. 120/15.26)

15.27 KSRB 15.4.5 : Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials Sqm 8.00
complete as per specification (PWD SR2011-12/P.No. 120/15.27)

15.28 KSRB 15.4.6 : Extra for providing and mixing waterproofing compound in
cement plaster for brick masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:3, Sqm 11.00
20mm thick cost of materials complete as per specification (PWD
SR2011-12/P.No. 120/15.28)

15.29 KSRB 15.4.7 : Extra for providing and mixing water proofing compound in
cement plaster for brick masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:4, Sqm 8.00
20mm thick cost of materials complete as per specification (PWD
SR2011-12/P.No. 120/15.29)

15.30 KSRB 15.5.1 : Providing rough cement plastering 15mm thick in single
coat with cement mortar 1:4, to brick masonry for base of dadooing works
with sand of approved quality, providing and removing scaffolding, Sqm 125.00
including cost of materials, labour, curing, complete as per specification.
(PWD SR2011-12/P.No. 120/15.30)

15.31 KSRB 15.5.2 : Providing rough cement plastering 15mm thick in single
coat with cement mortar 1:6, to brick masonry for base of dadooing works
with sand of approved quality, providing and removing scaffolding, Sqm 109.00
including cost of materials, labour, curing, complete as per specification.
(PWD SR2011-12/P.No. 121/15.31)

15.32 KSRB 15-6 : Providing floating coat of cement to plastering and finishing
smooth, including cost of materials, labour, curing, complete as per Sqm 14.50
specification. (PWD SR2011-12/P.No. 121/15.32)

15.33 KSRB 15.7 : Providing lime rendering for plastering to wall and ceiling,
including cost of materials, labour, curing complete as per specifications. Sqm 16.50
(PWD SR2011-12/P.No. 121/15.33)

15.34 KSRB 15.8.1 : Providing and fixing plaster mesh 100 mm wide
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along route of walls
chipped for services, junction between RCC and brick walls including cost
m 24.50
of materials, labour for fixing complete as per specifications. (length of
mesh only be measured for payment). (PWD SR2011-12/P.No. 121/15.34)
15.35 KSRB 15.8.2 : Providing and fixing plaster mesh 150 mm wide
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along route of walls
chipped for services, junction between RCC and brick walls including cost m 30.50
of materials, labour for fixing complete as per specifications. (length of
mesh only be measured for payment). (PWD SR2011-12/P.No. 121/15.35)

15.36 KSRB 15.8.3 : Providing and fixing plaster mesh 200 mm wide
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along route of walls
chipped for services, junction between RCC and brick walls including cost
m 36.50
of materials, labour for fixing complete as per specifications. (length of
mesh only be measured for payment). (PWD SR2011-12/P.No. 121/15.36)

15.37 KSRB 15.9 : Providing and fixing corner beads 45x 45mm size
manufactured out of hot dipped galvanised iron of nominal thickness
0.35mm with a zinc coating of 120gms per sqm width, along exposed
corners of walls, coloumns, lintels including cost of materials, labour for m 19.00
fixing complete (length of mesh only be measured for payment). (PWD
SR2011-12/P.No. 121/15.37)

15.38 KSRB 15.10.1 : Providing white washing to new wall surface in two coats
with lime of approved quality, to given an even shade including csot of
materials, labour, complete as per specification (PWD SR2011-12/P.No. Sqm 5.50
121/15.38)

15.39 KSRB 15.10.2 : Providing white washing for every one additional coat
with lime of approved quality, to give an even shade including cost of
materials, labour, complete as per specifications. (PWD SR2011- Sqm 2.50
12/P.No.121/15.39)

15.40 KSRB 15.10.3 : Providing white washing to ceiling and / or sloping roof
surface in two coats with lime of approved quality, to give an even shade
including cost of materials, labour, complete as per specifications. (PWD Sqm 6.00
SR2011-12/P.No. 121/15.40)

15.41 KSRB 15.10.4 : Providing white washing to ceiling and / or sloping roof
surface with additional one coat with lime of approved quality, to give an
even shade including cost of materials, labour, complete as per Sqm 3.00
specifications. (PWD SR2011-12/P.No. 121/15.41)

15.42 KSRB 15.11.1 : Providing cement washing to rough wall surface in one
coat with portland cement slurry to give an even shade after throughly
brooming the surface to remove all dirt, dust, mortar drops and other Sqm 5.00
foreign matter including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 121/15.42)
15.43 KSRB 15.11.2 : Providing cement washing on iron surface in one coat
with portland cement slurry mixed with boiled linseed oil to give an even
surface after throughly cleaning the surface to remove all dirt, dust, mortar Sqm 47.50
drops and other foreign matter including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 122/15.43)

15.44 KSRB 15.12.1 : Providing Gopi colour washing to new wall surface in two
coats with lime and gopi colour of approved quality, to give an even shade
after throughly brooming the surface to remove all dirt, mortar drops and Sqm 8.00
other foreign matter including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 122/15.44)

15.45 KSRB 15.12.2 : Providing Gopi colour washing to new wall surface in one
coat with lime and gopi colour of approved quality, to give an even shade
after throughly brooming the surface to remove all dirt, dust, mortar drops Sqm 4.00
and other foreign matter including cost of materials, labour, complete as
per specifications. (PWD SR2011-12/P.No. 122/15.45)

15.46 KSRB 15.13 : Applying of distemper KSRB 15-13.1 : Providing and


applying one coat distemper primer of approved brand on wall surface
after throughly brooming the surface to remove all dirt, dust, mortar drops
and other foreign matter including preparing the surface, even and sand
paper smooth, cost of materials labour, complete as per specifications.
(PWD SR2011-12/P.No. 122/15.46)

15.46.1 KSRB 15.13 : Applying of distemper KSRB 15-13.1 : Providing and


applying one coat distemper primer of approved brand on wall surface
after throughly brooming the surface to remove all dirt, dust, mortar drops
and other foreign matter including preparing the surface, even and sand Sqm 18.50
paper smooth, cost of materials labour, complete as per specifications.
Wall surface (PWD SR2011-12/P.No.122/15.46.1)

15.46.2 KSRB 15.13.2 : Extra over item 15-13.1 for apprying one coat of
distemper primer over ceiling and / or sloping roof as per specifications. Sqm 1.50
(PWD SR2011-12/P.No. 122/15.46.2)

15.47 KSRB 15.13.3 : Providing and applying two coats dry distemper of
approved brand, and shade on wall surface including priming coat and
whitening after throughly brooming the surface to remove all dirt, dust,
mortar drops and other foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No.122/15.47)

15.47.1 KSRB 15.13.3 : Providing and applying two coats dry distemper of
approved brand, and shade on wall surface including priming coat and
whitening after throughly brooming the surface to remove all dirt, dust,
mortar drops and other foreign matter including preparing the surface Sqm 37.00
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 122/15.47.1)
15.47.2 KSRB 15.13.4 : Extra over item 15-13.3 for appying distemper primer
over ceiling and / or sloping roof as per specification. (PWD SR2011- Sqm 3.00
12/P.No. 122/15.47.2)

15.48 KSRB 15.13.5 : Providing and applying one coat on old surface dry
distemper of approved brand, and shade on wall surface after throughly
brooming the surface clean of all gease, dirt, loose pieces of scales
including preparing the surface even and sand paper smooth, cost of
material, labour, complete as per specification (PWD SR2011-12/P.No.
122/15.48)

15.48.1 KSRB 15.13.5 : Providing and applying one coat on old surface dry
distemper of approved brand, and shade on wall surface after throughly
brooming the surface clean of all gease, dirt, loose pieces of scales
including preparing the surface even and sand paper smooth, cost of Sqm 11.00
material, labour, complete as per specification wall surface (PWD
SR2011-12/P.No.122/15.48.1)

15.48.2 KSRB 15.13.6 : Extra over item 15-13.5 for applying distemper over
ceiling and / or sloping roof as per specifications. (PWD SR2011-12/P.No. Sqm 1.00
122/15.48.2)

15.48.3 KSRB 15.13.7 : Extra for providing and applying every subsequent cost of
dry distemper of approved brand, for item no.15-13.3 & 15-13.5 of
approved shade on wall surface cost of materials, labour, complete as per Sqm 7.50
specifications. (PWD SR2011-12/P.No. 123/15.48.3)

15.49 KSRB 15.14.1 : Providing and applying two coats with oil bound washable
distemper of approved brand and shade on wall surface including priming
coat with distemper primer after throughly brooming the surface free from
mortar drops and other foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 123/15.49)

15.49.1 KSRB 15.14.1 : Providing and applying two coats with oil bound washable
distemper of approved brand and shade on wall surface including priming
coat with distemper primer after throughly brooming the surface free from
mortar drops and other foreign matter including preparing the surface Sqm 52.50
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 123/15.49.1)

15.49.2 KSRB 15.14.2 : Extra over item 15-14.1 for applying oil bound washable
distemper on ceiling and / or sloping roof as per specifications. (PWD Sqm 3.50
SR2011-12/P.No. 123/15.49.2)
15.50 KSRB 15.14.3 : Providing and applying one coat with oil bound washable
distemper of approved brand and shade on wall surface to give an even
shade after throughly brooming the surface free from all grease, dirt, loose
peases of scales, including preparing the surface even and sand paper
smooth, cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 123/15.50)

15.50.1 KSRB 15.14.3 : Providing and applying one coat with oil bound washable
distemper of approved brand and shade on wall surface to give an even
shade after throughly brooming the surface free from all grease, dirt, loose
peases of scales, including preparing the surface even and sand paper Sqm 21.00
smooth, cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 123/15.50.1)

15.50.2 KSRB 15.14.4 : Extra over item 15-14.3 for applying one coat with oil
bound washable distemper on ceiling and / or sloping roof as per Sqm 1.50
specifications. (PWD SR2011-12/P.No. 123/15.50.2)

15.51 KSRB 15.15.1: Providing and applying painting in two coats with plastic
emulsion paint of approved brand on wall surface to give an even
approved shade after throughly brushing the surface, free from mortar
drops and other foreign matter including preparing the surface even and
sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 123/15.51)

15.51.1 KSRB 15.15.1: Providing and applying painting in two coats with plastic
emulsion paint of approved brand on wall surface to give an even
approved shade after throughly brushing the surface, free from mortar
drops and other foreign matter including preparing the surface even and Sqm 55.00
sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 123/15.51)

15.51.2 KSRB 15.15.1: Providing and applying painting in two coats with Primer
with plastic emulsion paint of approved brand on wall surface to give an
even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface Sqm 66.00
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 123/15.51.2)

15.51.3 KSRB 15.15.2 : Extra over item 15-15.1 for applying two coats with plastic
emulsion paint of approved brand and shade on ceiling and / or sloping Sqm 2.50
roof as per specifications. (PWD SR2011-12/P.No. 123/15.51.3)

15.52 KSRB 15.15.3 : Providing and applying painting in one coat with plastic
emulsion paint of approved brand and manufacture on wall surface to give
an even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 123/15.52)
15.52.1 KSRB 15.15.3 : Providing and applying painting in one coat with plastic
emulsion paint of approved brand and manufacture on wall surface to give
an even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface
Sqm 35.00
even and sand paper smooth, cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 124/15.52.1)

15.52.2 KSRB 15.15.4 : Extra over item 15-15.3 for painting with one coat plastic
emulsion paint of approved brand and shade on ceiling and / or sloping
roof as per specifications. (PWD SR2011-12/P.No. 124/15.52.2) Sqm 2.00

15.52.3 KSRB 15.15.5 : Extra for providing and applying every subsequent coat of
painting with plastic emulsion paint of approved brand and shade for item
no. 15-15.1 and 15-15.3 cost of materials, labour, complete as per Sqm 23.00
specifications. (PWD SR2011-12/P.No. 124/15.52.3)

15.53 KSRB 15-16.1 : Providing and finishing external walls in two coats with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
124/15.53)

15.53.1 KSRB 15-16.1 : Providing and finishing external walls in two coats with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of Sqm 45.50
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
124/15.53.1)

15.53.2 KSRB 15.16 : Water proof cement paint KSRB 15-16.1 : Providing and
finishing external walls in two coats with waterproof cement paint with
primer of approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free Sqm 60.00
from mortar drops and other foreign matter cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No.124/15.53.2)

15.53.3 KSRB 15.16.3 : Extra for providing and applying every subsequent coat of
waterproofing cement paint of approved brand and shade for item no. 15-
16.1 cost of materials, labour, complete as per specifications. (PWD Sqm 17.50
SR2011-12/P.No. 124/15.53.3)
15.54 KSRB 15.16 : Water proof cement paint KSRB 15-16.2 : Providing and
finishing external walls in one coat with waterproof cement paint of
approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free
from mortar drops and other foreign matter cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 124/15.54)

15.54.1 KSRB 15.16 : Water proof cement paint KSRB 15-16.2 : Providing and
finishing external walls in one coat with waterproof cement paint of
approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free
Sqm 26.00
from mortar drops and other foreign matter cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 124/15.54.1)

15.54.2 KSRB 15.16 : Water proof cement paint KSRB 15-16.2 : Providing and
finishing external walls in one coat with waterproof cement paint with
primer of approved brand and shade to give an even shade after throughly
brooming the surface to remove all dirt and loose powdered material, free
from mortar drops and other foreign matter cost of materials, labour, Sqm 32.50
complete as per specifications. (PWD SR2011-12/P.No. 124/15.54.2)

15.54.3 KSRB 15.16.3 : Extra for providing and applying every subsequent coat of
waterproofing cement paint of approved brand and shade for item no. 15-
16.1 and 15-16.2 cost of materials, labour, complete as per specifications. Sqm 17.50
(PWD SR2011-12/P.No. 124/15.54.3)

15.55 KSRB 15.17 : Painting of wood surface KSRB 15-17.21 : Applying


priming coat over new wood surface and / or wood based surface with
while lead paint preming including preparing the surface after throughly
cleaning oil, grease, dirt and foreign matter, sand papering and knotting Sqm 26.00
ready mix paint including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 124/15.55)

15.56 KSRB 15.17.2 : Applying priming coat over new wood surface and / or
wood based surface after brushing with wood primer pink paint including
preparing the surface after throughly cleaning oil, grease, dirt and foreign
matter, sand papering and knotting ready mix paint including cost of Sqm 24.00
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
124/15.56)

15.57 KSRB 15.17.3 : Applying priming coat over new wood surface and / or
wood based surface after brushing with aluminium paint primer, water
resistant including preparing the surface after throughly cleaning oil,
grease, dirt and foreign matter, sand papering and knotting ready mix Sqm 25.00
paint including cost of materials, labour, complete as per specifications.
(PWD SR2011-12/P.No. 125/15.57)
15.58 KSRB 15.17.4 : Applying priming coat over new wood surface and / or
wood based surface after brushing with ready mix eanamel priming paint
including preparing the surface after throughly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting ready mix paint including Sqm 24.00
cost of materials, labour, complete as per specifications. (PWD SR2011-
12/P.No. 125/15.58)

15.59 KSRB 15.17.5 : Applying priming coat over new wood surface and / or
wood based surface after preparing the surface after throughly cleaning
oil, grease, dirt and foreign matter, sand papering and knotting liquid wood Sqm 26.50
filler, for varnish including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 125/15.59)

15.60 KSRB 15.17.6 : Providing and applying painting two coats (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust
and forign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 125/15.60)

15.60.1 KSRB 15.17.7 : Providing and applying painting two coats (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust Sqm 73.00
and forign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 125/15.60.1)

15.60.2 KSRB 15.17.8 : Extra over item No 15-17.6 for applying every subsequent
coat of enamel paint to give an even shade after cleaning the surface of
all dirt, dust and foreign matter, sand papering including cost of materials, Sqm 42.00
labour, complete as per specification. (PWD SR2011-12/P.No.
124/15.60.2)

15.61 KSRB 15.17.7 : Providing and applying painting one coat (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust
and forign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 124/15.60.1)

15.61.1 KSRB 15.17.7 : Providing and applying painting one coat (excluding
priming coat) on new wood surface and / or wood based surface with
enamel paint to give and even shade, cleaning the surface of all dirt, dust
and forign matter, sand papering including cost of materials, labour, Sqm 45.00
complete as per specifications. (PWD SR2011-12/P.No. 125/15.61.1)

15.61.2 KSRB 15.17.8 : Extra over item No 15-17.7 for applying every subsequent
coat of enamel paint to give an even shade after cleaning the surface of
all dirt, dust and foreign matter, sand paperig including cost of materials, Sqm 42.00
labour, complete as per specifications. (PWD SR2011-12/P.No.
125/15.61.2)
15.62 KSRB 15.17.9 : Applying varnish two coats (excluding priming coat) on
new wood surface and / or wood based surface undercoating with flatting
varnish and finishing coat with varnish to give an even shade after
cleaming so as to produce smooth dry, mat surface including cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
125/15.62)

15.62.1 KSRB 15.17.9 : Applying varnish two coats (excluding priming coat) on
new wood surface and / or wood based surface undercoating with flatting
varnish and finishing coat with varnish to give an even shade after
cleaming so as to produce smooth dry, mat surface including cost of Sqm 48.00
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
125/15.62)

15.62.2 KSRB 15.17.11 : Extra over item No 15-17.9 and 15.17.10 for applying
every subsequent coat of varnish to produce a smooth dry and mat
surface after cleaning the surface of all dirt, dust and foreign matter, Sqm 43.00
including cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 125/15.62.2)

15.63 KSRB 15.17.10 : Providing and Applying varnishing one coat (excluding
priming coat) on previously varnished wood / or wood based surface to
give an even surface after cleaning the surface of all dirt, dust and foreign
matter, sand papering so as to produce a smooth dry and mat surface
including cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 126/15.63)

15.63.1 KSRB 15.17.10 : Providing and Applying varnishing one coat (excluding
priming coat) on previously varnished wood / or wood based surface to
give an even surface after cleaning the surface of all dirt, dust and foreign
matter, sand papering so as to produce a smooth dry and mat surface Sqm 25.00
including cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 126/15.63)

15.63.2 KSRB 15.17.11 : Extra over item No. 15-17.9 and 15-17.10 for applying
every subsequent coat of varnish to produce a smooth dry and mat
surface after cleaning the surface of all dirt, dust and foreign matter, Sqm 23.00
including cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 126/15.63.2)

15.64 KSRB 15.17.12 : Providing and Applying polishing with french polish on
new wood surface and / or wood based suface to give an even surface
after cleaning the surface of all dirt, dust and foreign matter, sand papered Sqm 96.00
smooth including cost of materials, labour, complete as per specifications.
(PWD SR2011-12/P.No. 126/15.64)

15.65 KSRB 15.17.13 : Providing and Applying polishing with french polish over
previously polished wood or wood based surface to give an even surface
after cleaning the surface of all dirt, dust and foreign matter, sand papered Sqm 49.50
smooth including cost of materials, labour, complete as per specifications.
(PWD SR2011-12/P.No. 126/15.65)
15.66 KSRB 15.17.14 : Providing and Applying wax polish in two coats on new
wood surface and / or wood based surface with bees wax polish in
proportion of 2:1.5:1:0.5 (2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5
varnish by weight) to give an even surface after cleaning the surface of all Sqm 45.50
dirt, dust and foreign matter, sand papered smooth including cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
126/15.66)

15.67 KSRB 15.17.15 : Providing and Applying wax polish in single coat on new
wood surface and / or wood based surface with bees wax polish in
proportion of 2:1.5:1:0.5 (2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5
varnish by weight) to give an even surface after cleaning the surface of all Sqm 23.00
dirt, dust and foreign matter, sand papered smooth including cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
126/15.67)

15.68 KSRB 15.17.16 : Providing and applying painting two coat (excluding
priming coat) on new wood surface and / or wood based surface with coal
tar paint to give an even shade after cleaning the surface of all dirt, dust Sqm 27.00
and foreign matter, including cost of materials, labour, complete as per
speciications. (PWD SR2011-12/P.No. 126/15.68)

15.69 KSRB 15.17.17 : Providing and applying painting one coat (excluding
priming coat) on new wood surface and / or wood based surface with coal
tar paint to give an even shade after cleaning the surface of all dirt, dust Sqm 18.00
and foreign matter, including cost of materials, labour, complete as per
speciications. (PWD SR2011-12/P.No. 126/15.69)

15.70 KSRB 15.17.18 : Providing and applying painting one coat (excluding
priming coat) on previously painted wood surface and / or wood based
surface with coal tap paint to give an even shade after cleaning the
surface of all dirt. dust and foreign matter, including cost of materials, Sqm 15.00
labour, complete as per specifications. (PWD SR2011-12/P.No.
127/15.70)

15.71 KSRB 15.17.19 : Providing and applying painting one coat (excluding
priming coat) on previously painted wood surface and / or wood based
surface with black japan paint to give an even shade after cleaning the
surface of all dirt. dust and foreign matter, including cost of materials, Sqm 26.00
labour, complete as per specifications. (PWD SR2011-12/P.No.
127/15.71)

15.72 KSRB 15.17.20 : Applying additional one coat (excluding priming coat) on
previously painted wood surface and / or wood based surface with black
japan paint to give an even shade after cleaning the surface of all dirt. Sqm 23.00
dust and foreign matter, including cost of materials, labour, complete as
per specifications. (PWD SR2011-12/P.No. 127/15.72)

15.73 KSRB 15.18.1 : Applying red lead ready mix priming coat over new steel
or other metal surface including preparing the surface after throughly
cleaning oil, grease, dirt and other foreign matter, and scoured with wire Sqm 22.00
brushes, fine steel wool, sand papers including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 127/15.73)
15.74 KSRB 15.18.2 : Providing and applying enamel metal paint two coats
(excluding priming coat) over new steel or other metal surface brushing to
give an even shade after cleaning oil, grease, dirt and other foreign Sqm 71.00
matter, including cost of materials, labour, complete as per specifications.
(PWD SR2011-12/P.No. 127/15.74)

15.75 KSRB 15.18.3 : Providing and applying enamel metal paint one coat
(excluding priming coat) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 44.00
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 127/15.75)

15.76 KSRB 15.18.4 : Providing and applying alluminium paint two coats
(excluding priming coat) over new steel or other metal surface brushing to
give an even shade after cleaning oil, grease, dirt and other foreign Sqm 42.00
matter, including cost of materials, labour, complete as per specifications.
(PWD SR2011-12/P.No. 127/15.76)

15.77 KSRB 15.18.5 : Providing and applying alluminium paint one coat
(excluding priming coat) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 26.50
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 127/15.77)

15.78 KSRB 15.18.6 : Providing and applying black japan paint one coat
(excluding priming coat) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 26.00
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 127/15.78)

15.79 KSRB 15.18.7 : Extra for applying every subsequent black japan paint on
previously painted steel or other metal surface brushing to give an even
shade after cleaning oil, grease, dirt and other foreign matter, including Sqm 23.00
cost of materials, labour, complete as per specifications. (PWD SR2011-
12/P.No. 128/15.79)

15.80 KSRB 15.19.1 : Providing and applying ready mix priming coat over
concrete / masonry / asbestos cement sheet / plastered surfaces including
preparing the surface after throughly cleaning of oil, grease, dirt and other Sqm 20.00
foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 128/15.80)

15.81 KSRB 15.19.2 : Providing and applying spray painting in two coats
(exluding priming coat) over concrete / masonry / asbestos cement sheet /
plastered surfaces wtih flat wall paint of approved brand to give even
shade after cleaning the surface of all dirt, dust and other foreign matter, Sqm 52.50
and sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 127/15.81)
15.82 KSRB 15.19.3 : Providing and applying spray painting in one coat
(exluding priming coat) over concrete / masonry / asbestos cement sheet /
plastered surfaces wtih flat wall paint of approved brand to give even
shade after cleaning the surface of all dirt, dust and other foreign matter, Sqm 33.00
and sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 128/15.82)

15.83 KSRB 15.20.1 : Providing and applying floor painting with ready mix paint
in two coats (exluding priming coat) on new concrete / asbestos cement
sheet / plastered surfaces brushing to give an even shade after preparing
the surface after throughly cleaning oil, dirt, dust other foreign matter and Sqm 38.00
sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 128/15.83)

15.84 KSRB 15.20.2 : Providing and applying floor painting with ready mix paint
in one coat (excluding priming coat) on new concrete / asbestos cement
sheet / plastered surfaces brushing to give an even shade after preparing
the surface after throughly cleaning oil, dirt, dust other foreign matter and Sqm 24.50
sand papering including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 128/15.84)

15.85 KSRB 15.21.1 : Providing and applying wax polish on new concrete floor
and vertical plastered surface using approved brand to give an even
shade after preparing the surface after throughly cleaning oil, dirt, dust Sqm 21.00
othe foreign matter, including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 128/15.85)

15.86 KSRB 15.21.2 : Providing and applying wax polish on previously polished
concrete floor and vertical plastered surface using wax polish of approved
brand to give an even shade after preparing the surface after throughly
cleaning oil, dirt, dust and other foreign matter, including cost of materials, Sqm 20.00
labour, complete as per specifications. (PWD SR2011-12/P.No.
128/15.86)

15.87 KSRB 15.22.1 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size dark shade pigment with ordinary cement
(in top layer only) laid in cement marble powder 3:1 (3 cement : 1 marble
powder by weight) in proportion of 4:7 (4 cement marble powder mix : 7 Sqm 737.00
marble chips by volume) overall thickness 24mm (18mm thick under layer,
6mm thick top layer) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
128/15.87)
15.88 KSRB 15.22.2 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, light shade pigment with white cement (in
top layer only) laid in cement marble powder 3:1 (3 cement : 1 marble
powder by weight) in proportion of 4:7 (4 cement marble powder mix : 7 Sqm 774.00
marble chips by volume) overall thickness 24mm (18mm thick under layer,
6mm thick top layer) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
129/15.88)

15.89 KSRB 15.22.3 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, medium shade pigment with approximately
50% white cement and 50% ordinary cement (in top layer only) laid in
cement marble powder 3:1 (3 cement : 1 marble powder by weight) in
Sqm 767.00
proportion of 4:7 (4 cement marble powder mix : 7 marble chips by
volume) overall thickness 24mm (18mm thick under layer, 6mm thick top
layer) in cement mortar of mix 1:3 including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 129/15.89)

15.90 KSRB 15.22.4 : Providing marble chips skirting or dado (upto 30cms
height) rubbed and polished to granolithic finish, top layer 6mm thik with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, white cement without any pigment (in top
layer only) laid in cement marble powder 3:1 (3 cement : 1 marble powder
by weight) in proportion of 4:7 (4 cement marble powder mix : 7 marble Sqm 716.00
chips by volume) overall thickness 24mm (18mm thick under layer, 6mm
thick top layer) in cement mortar of mix 1:3 including cost of materials,
labour, complete as per specifications. (PWD SR2011-12/P.No.
129/15.90)

15.91 KSRB 15.22.5 : Extra labour for work in dado exceeding 30 cms in height
including cost of labour, complete as per specifications. (PWD SR2011- Sqm 13.50
12/P.No. 129/15.91)

15.92 KSRB 15.23.1 : Providing pre-cast mosaic tiles 20mm thick with marble
chips of white, black, chocolate, grey, yellow or baroda green from
smallest to 6mm nominal size with ordinary cement (in top layer only) for
skirting and rises of steps (not exceeding 30cms height) on 10 cms thick m 224.00
cement mortar 1:3 jointed with neat cement slurry, rubbed and polished to
granolitic finish, including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 129/15.92)
15.93 KSRB 15.23.2 : Providing pre-cast mosaic tiles using light shade pigmant
with white cement 20mm thick with marble chips of white, black,
chocolate, grey, yellow or baroda green from smallest to 6mm nominal
sizewith ordinary cement (in top layer only) for skirting and rises of steps
(not exceeding 30cms height) on 10 cms thick cement mortar 1:3 jointed m 273.00
with neat cement slurry, rubbed and polished to granolitic finish, including
cost of materials, labour, complete as per specifications. (PWD SR2011-
12/P.No. 129/15.93)

15.94 KSRB 15.23.3 : Providing pre-cast mosaic tiles using medium shade
pigmant using approximately 50% white cement and 50% ordinary cement
20mm thick with marble chips of white, black, chocolate, grey, yellow or
baroda green from smallest to 6mm nominal sizewith ordinary cement (in
top layer only) for skirting and rises of steps (not exceeding 30cms height)
m 224.00
on 10 cms thick cement mortar 1:3 jointed with neat cement slurry, rubbed
and polished to granolitic finish, including cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 130/15.94)

15.95 KSRB 15.23.4 : Providing pre-cast mosaic tiles of white shade with white
cement whithout any pigmant 20mm thick with marble chips of white,
black, chocolate, grey, yellow or baroda green from smallest to 6mm
nominal size with ordinary cement (in top layer only) for skirting and rises
of steps (not exceeding 30cms height) on 10 cms thick cement mortar 1:3 m 188.00
jointed with neat cement slurry, rubbed and polished to granolitic finish,
including cost of materials, labour, complete as per specifications. (PWD
SR2011-12/P.No. 130/15.95)

15.96 Providing melamine polishing of approved shade including removing and


refixing of doors shutters scraping with blade and rubbing with zero size
sand paper and applying sealer coat by way of spraying with necessary
compressor and applying patty after rubbing with steel wool including two Sqm 561.00
coats of approved shade of melamine polish etc., complete (PWD
SR2011-12/P.No. 130/15.96)

15.97 Providing melamine polishing of approved shade including removing and


refixing of doors shutters, glass, beading and existing polishing, scraping
with blade and rubbing with zero size sand paper and applying sealer coat
by way of spraying with necessary compressor and applying patty after Sqm 715.00
rubbing with steel wool including two coats of approved shade of
melamine polish etc., complete. (PWD SR2011-12/P.No. 130/15.97)

15.98 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of
cement. (PWD SR2011-12/P.No. 130/15.98)

15.98.1 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 4.50
cement. for CM 1:4, 20mm thick (PWD SR2011-12/P.No. 130/15.98.1)
15.98.2 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 3.50
cement. for CM 1:4, 12mm thick (PWD SR2011-12/P.No. 130/15.98.2)

15.98.3 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 3.00
cement. for CM 1:6, 20mm thick (PWD SR2011-12/P.No. 130/15.98.3)

15.98.4 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement i.e., 0.25% by weight of Sqm 2.50
cement. for CM 1:6, 12mm thick (PWD SR2011-12/P.No. 130/15.98.4)

15.99 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers for use as micro secondary reinforcement in guitie and
shotcrete civil works with application dosage of 125-175 grams per bag of Sqm 10.00
cement i.e. 0.25% - 0.30% by weight of cement (PWD SR2011-12/P.No.
130/15.99)

15.100 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster.
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. (PWD SR2011-
12/P.No. 130/15.100)

15.100.1 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 23.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:3, 20mm thick
(PWD SR2011-12/P.No. 131/15.100.1)
15.100.2 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 15.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:3, 12mm thick
(PWD SR2011-12/P.No. 131/15.100.2)

15.100.3 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 21.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:4, 20mm thick
(PWD SR2011-12/P.No. 131/15.100.3)

15.100.4 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster.
Sqm 13.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:4, 12mm thick
(PWD SR2011-12/P.No. 131/15.100.4)

15.100.5 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 18.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:6, 20mm thick
(PWD SR2011-12/P.No. 131/15.100.5)

15.100.6 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @ 125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and
200 gms for 1:6 CM mix per bag of cement in both coats of the plaster.
Sqm 13.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confiming to ASTM C 1116 ACI 524-93. for CM 1:6, 12mm thick
(PWD SR2011-12/P.No. 131/15.100.6)
15.101 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 (PWD SR2011-
12/P.No. 131/15.101)

15.101.1 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for Sqm 38.00
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:3,
20mm thick (PWD SR2011-12/P.No. 131/15.101.1)

15.101.2 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for Sqm 25.00
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:3,
12mm thick (PWD SR2011-12/P.No. 131/15.101.2)

15.101.3 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for Sqm 34.00
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:4,
20mm thick (PWD SR2011-12/P.No. 131/15.101.3)
15.101.4 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for Sqm 21.00
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:4,
12mm thick (PWD SR2011-12/P.No. 131/15.101.4)

15.101.5 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for Sqm 32.00
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:6,
20mm thick (PWD SR2011-12/P.No. 131/15.101.5)

15.101.6 Providing and mixing fiber mesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process. It should prevent the growth of micro organisms like bacteria,
mold fungus, mildew etc., on concrete surfaces. Application top of plaster
to be mixed in mechanical mixer at 150 gm of fibers per bag of cement for Sqm 28.50
CM 1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth
micro blocker shall confirm to ASTM C-116 type 111 4.1.3 for CM 1:6,
12mm thick (PWD SR2011-12/P.No. 131/15.101.6)

15.102 Providing and mixing Harbourite 12mm fibrillated 100% virgin


polypropylene fibers which should be free from reprocessed olefin
materials and specifically manufactured for use as cementitious micro
reinforcement application rate of 175 gms to 250 gms per bag of cement
or 1.8 kg per cum in the guinite/shotcret and designed to an optimum Sqm 67.00
gradation for use as concrete secondary reinforcement. Fiber mesh
Harbourite fibers 12mm fibers should be confirming to ASTM C-1116
(PWD SR2011-12/P.No. 131/15.102)

15.103 Providing external walls with texture finish using approved brand paint,
applied uniformly in three coats over one coat of primer including cost of
all materials, machineries, labour, transportation, loading and unloading,
lead and lift and all other incidental charges including scaffolding and Sqm 225.00
removing stains, complete as per specifications. (PWD SR2011-12/P.No.
131/15.103)
15.104 Providing and finishing external walls intwo coats over one coat of primer
with antifungal paint of approved brand and shade to give an even shade
after throughly brooming the surface to remove all dirt and loose
powdered material, free mortar drops and other foreign matter cost of Sqm 115.00
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
131/15.104)

15.105 Providing textured paint of approved qualit, colour and shade to wall
surface after cleaning and rubbing the wall surface with wire brush of
medium size emery stone to remove all the loosely adhering particles, the
surface is then cleaned with water and ensured that it is in line and level.
The textured material is then mixed with 40-50% of clean water until a
homogeneous thick slurry is formed, the slurry is left for 5-10 min, to react
completely with ingredients. The textured finish prepared as above is then
applied to the wall surface with suitable roller/spray gun/ putty/ blade/
trowel to get the desired finish. The finished surface shall be applied with Sqm 283.00
two coats of exterior apex paint of approved shade. The rate includes
providing and removing scaffolding, all lead and lift and all other incidental
charges etc., complete as per directions of the Engineer-in-charge of the
work. (PWD SR2011-12/P.No. 132/15.105)
REPAIRS TO BUILDINGS

16.1 KSRB 24.1 : Removing white wash or colour wash by steel brushing and /
or scraping, sand papering and preparing wall surface smooth including
repairs to scraches, cost of labour complete as per specifications. (PWD
SR2011-12/P.No. 134/16.1)

16.1.1 KSRB 24.1 : Removing white wash or colour wash by steel brushing and /
or scraping, sand papering and preparing wall surface smooth including
repairs to scraches, cost of labour complete as per specifications. (PWD Sqm 4.00
SR2011-12/P.No. 134/16.1.1)

16.1.2 KSRB 24.2 :Removing white wash or colour wash by steel brushing and /
or scraping, sand papering the ceiling and / or sloping roof surface smooth
including repairs to scraches, cost of labour complete as per Sqm 4.50
specifications. (PWD SR2011-12/P.No. 134/16.1.2)

16.1.3 KSRB 24.3 : Extra for washing the wall surface spoiled by smoke, soot,
with clear water before sand papering the A80 surface smooth including
necessary repairs to scraches, cost of labour, complete as per Sqm 2.00
specifications. (PWD SR2011-12/P.No. 134/16.1.3)

16.1.4 KSRB 24.4 : Extra for item No. 24-3 washing the ceiling and / or sloping
wall surface spoiled by smoke, soot, with clear water before sand papering
the A80 surface smooth including necessary repairs to scraches, cost of Sqm 2.00
labour, complete as per specifications. (PWD SR2011-12/P.No.
134/16.1.4)

16.2 KSRB 24.5 : Cleaning and washing of decorated wall surface with soap
and water including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 134/16.2)

16.2.1 KSRB 24.5 : Cleaning and washing of decorated wall surface with soap
and water including cost of materials, labour, complete as per Sqm 2.00
specifications. (PWD SR2011-12/P.No. 134/16.2.1)

16.2.2 KSRB 24.6 : Extra for KSRB 24-5 cleaning and washing the old ceiling
and / or sloping roof with soap, soda and water including cost of materials,
labour, complete as per specifications. (PWD SR2011-12/P.No. Sqm 2.00
134/16.2.2)

16.3 KSRB 24.7 : Cleaning and washing the old plastered wall surface with
soap, soda, water including cost of materials, labour, complete as per
specifications. (PWD SR2011-12/P.No. 134/16.3)

16.3.1 KSRB 24.7 : Cleaning and washing the old plastered wall surface with
soap, soda, water including cost of materials, labour, complete as per Sqm 2.00
specifications. (PWD SR2011-12/P.No. 134/16.3.1)
16.3.2 KSRB 24.8 : Cleaning and washing the old plastered ceiling and / or
sloping roof surface with soap, soda, water including cost of materials,
labour, complete as per specifications (PWD SR2011-12/P.No. 134/16.3.2) Sqm 2.00

16.4 KSRB 24.9 : Cleaning and washing of stone masonry wall surface with
nitric acid including cost of materials, labour, complete as per Sqm 3.00
specifications. (PWD SR2011-12/P.No. 134/16.4)

16.5 KSRB 24.10 : Removing the old paint or polish from wood and / or wood
based surface with paint remover of approved brand / manufactur and
making surface even including cost of materials, labour, complete as per Sqm 33.50
specifications. (PWD SR2011-12/P.No. 134/16.5)

16.6 KSRB 24.11 : Removing the old paint or polish from wood and / or wood
based surface with caustic soda solution and making surface even
including cost of materials, labour, complete as per specifications. (PWD Sqm 22.00
SR2011-12/P.No. 135/16.6)

16.7 KSRB 24.12 : Removing the old paint from wood and / or wood based
surface with blow lamp and making surface even including cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No. Sqm 45.00
135/16.7)

16.8 KSRB 24.13 : Removing the old paint from steel and / or other metal
surface with hand scraping and making surface even including cost of
labour, complete as per specifications. (PWD SR2011-12/P.No. 135/16.8) Sqm 37.00

16.9 KSRB 24.14 : Removing the old paint from steel and / or other metal
surface with flame cleaning and making surface even including cost of
labour, complete as per specifications. (PWD SR2011-12/P.No. 135/16.9) Sqm 45.00

16.10 KSRB 24.15 : Removing the old paint from steel and / or other metal
surface with paint remover of approved brand / manufacturer cleaning and
making surface even including cost of materials, labour, complete as per Sqm 33.00
specifications. (PWD SR2011-12/P.No. 135/16.10)

16.11 KSRB 24.16 : Fixing small pieces (not exceeding 0.015 cum) for making
good wherever hinges etc., have been removed from frames or joinery
etc., with teak wood excluding cost of materials but including cost of Piece 11.00
labour, complete as per specifications. (PWD SR2011-12/P.No. 135/16.11)

16.12 KSRB 24.17 : Providing and fixing small pieces (not exceeding 0.015
cum) for making good wherever hinges etc., have been removed from
frames or joinery etc., with honne wood including cost of materials, labour, Piece 137.00
complete as per specifications. (PWD SR2011-12/P.No. 135/16.12)
16.13 KSRB 24.18 : Providing and fixing small pieces (not exceeding 0.015
cum) for making good wherever hinges etc., have been removed from
frames or joinery etc., with matti / nandi wood including cost of materials, Piece 115.50
labour, complete as per specifications. (PWD SR2011-12/P.No. 135/16.13)

16.14 KSRB 24.19 : Providing and fixing small pieces (not exceeding 0.015
cum) for making good wherever hinges etc., have been removed from
frames or joinery etc., with sal wood including cost of materials, labour, Piece 83.00
complete as per specifications. (PWD SR2011-12/P.No. 135/16.14)

16.15 KSRB 24.20 : Renewing bars, styles and rails, straight for joinery upto 50
mm thick including mitres, haunching, mortices etc., and removing the old
defective pieces and replacing with Teak wood including cost of materials, Piece 770.00
labour, complete as per specifications. (PWD SR2011-12/P.No. 135/16.15)

16.16 KSRB 24.21 : Renewing bars, styles and rails, straight for joinery upto 50
mm thick including mitres, haunching, mortices etc., and removing the old
defective pieces and replacing with Honne wood including cost of Piece 381.00
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
135/16.16)

16.17 KSRB 24.22 : Renewing bars, styles and rails, straight for joinery upto 50
mm thick including mitres, haunching, mortices etc., and removing the old
defective pieces and replacing with Matti/ Nandi wood including cost of Piece 324.00
materials, labour, complete as per specifications. (PWD SR2011-12/P.No.
135/16.17)

16.18 KSRB 24.23 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm per leaf, removing or
dismantling excluding cost of wood but including cost of labour, complete Leaf 253.00
as per specifications. (PWD SR2011-12/P.No. 135/16.18)

16.19 KSRB 24.24 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm but not exceeding
two sqm per leaf, removing or dismantling excluding cost of wood but Leaf 335.00
including cost of labour, complete as per specifications. (PWD SR2011-
12/P.No. 136/16.19)

16.20 KSRB 24.25 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding two sqm removing or Leaf 474.00
dismantling excluding cost of wood but including cost of labour, complete
as per specifications. (PWD SR2011-12/P.No. 136/16.20)

16.21 KSRB 24.26 : Making repairs to joinery at angles with 300mm x 25mm x
3mm length of MS flat forged to shape and let into wood work, counter
sunk, drilled and screwed including cost of materials, labour, complete as Each 59.50
per specifications. (PWD SR2011-12/P.No. 136/16.21)
16.22 KSRB 24.27 : Renewing Honne wood batterns in roof including making
good the holes in walls, removal of rubbish to the dumping round with a
lead upto 50 m including cost of materials, labour, complete as per Cum 9678.00
specifications. (PWD SR2011-12/P.No. 136/16.22)

16.23 KSRB 24.28 : Renewing Matti / Nandi wood batterns in roof including
making good the holes in walls, removal of rubbish to the dumping round
with a lead upto 50 m including cost of materials, labour, complete as per Cum 8373.00
specifications. (PWD SR2011-12/P.No. 136/16.23)

16.24 KSRB 24.29 : Renewing Sal wood battens in roof including making good
the holes in walls, removal of rubbish to the dumping round with a lead
upto 50 m including cost of materials, labour, complete as per Cum 6415.00
specifications. (PWD SR2011-12/P.No. 136/16.24)

16.25 KSRB 24.30 : Removal of old broken glass panes (any thickness of size,
quality or description) from wooden frames, glazed with putty or fixed with
beads including cost of labour, complete as per specifications. (PWD Sqm 54.50
SR2011-12/P.No. 136/16.25)

16.26 KSRB 24.31 : Removal of old broken glass panes (any thickness of size,
quality or description) from metal frames, glazed with putty or fixed with
beads including cost of labour, complete as per specifications. (PWD Sqm 77.00
SR2011-12/P.No. 136/16.26)

16.27 KSRB 24.32 : Removing serviceable glass of any description from old
wood or metal frames (any thickness or size, quality or description)
hacking out old putty etc., including risk and making good breakages in
taking out and handling, stacking within a lead of 50 m including cost of Sqm 78.50
labour, complete as per specifications. (PWD SR2011-12/P.No. 136/16.27)

16.28 KSRB 24.33 : Supplying and fixing new teak wood beads wherever
necessary including cost of materials, labour, complete as per m 26.00
specifications. (PWD SR2011-12/P.No. 136/16.28)

16.29 KSRB 24.34 : Supplying and fixing new Honne wood beads wherever
necessary including cost of materials, labour, complete as per m 17.50
specifications. (PWD SR2011-12/P.No. 136/16.29)

16.30 KSRB 24.34 : Renewal of old putty of glass panes including cost of
materials, labour, complete as per specifications. Specification No KBS m 19.50
24.2.6 (PWD SR2011-12/P.No. 136/16.30)

16.31 KSRB 24.36 : Removing the glazed tiles in patches in area exceeding 10
tiles and not exceeding 5 sqm including removing old tiles preparing
surface and laying or setting new or old tiles complete including cost of Sqm 401.00
materials, (excluding cost of tiles) labour, complete as per specifications.
(PWD SR2011-12/P.No. 136/16.31)
16.32 KSRB 24.37 : Removing the mosaic tiles in patches in area exceeding
10 tiles and not exceeding 5 sqm including removing old tiles preparing
surface and laying or setting new or old tiles complete including cost of Sqm 320.00
materials, (excluding cost of tiles) labour, complete as per specifications.
(PWD SR2011-12/P.No. 137/16.32)

16.33 KSRB 24.38 : Cutting out cracks of roof terrace to V - section cleaning
out, wetting, grouting with cement and sand slurry 1:3 (1 ceemnt, 3 sand)
including cost of materials, labour, complete as per specifications.(PWD m 31.00
SR2011-12/P.No. 137/16.33)

16.34 KSRB 24.39 : Cutting out cracks of roof terrace to V - section cleaning
out, and filling solidly with a hot mixure of bitumen and clean dry sand 1:1
by weight including cost of materials, labour, complete as per Sqm 31.00
specifications (PWD SR2011-12/P.No. 137/16.34)

16.35 KSRB 24.40 : Dubbing out on old irregular walls average 10 mm thick and
making good the surface with cement mortar 1:3 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS
24.2.1 (PWD SR2011-12/P.No. 137/16.35)

16.35.1 KSRB 24.40 : Dubbing out on old irregular walls average 10 mm thick and
making good the surface with cement mortar 1:3 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS Sqm 130.00
24.2.1 (PWD SR2011-12/P.No. 137/16.35.1)

16.35.2 KSRB 24.43 : Add from item No. 24-40 for every 5mm thick increase after
10mm with respective mortars including curing cost of materials, labour,
complete as per specifications. (PWD SR2011-12/P.No. 137/16.35.2) Sqm 35.00

16.36 KSRB 24.41 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:4 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS
24.2.1 (PWD SR2011-12/P.No. 137/16.36)

16.36.1 KSRB 24.41 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:4 including curing cost of
materials, labour, complete as per specifications. Specification No. KBS Sqm 111.00
24.2.1 (PWD SR2011-12/P.No. 137/16.36.1)

16.36.2 KSRB 24.43 : Add from Item No. 24.40, 24.41, 24.42 for every 5mm thick
increase after 10mm with respective mortars including curing cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No. Sqm 30.00
137/16.36.2)

16.37 KSRB 24.42 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:6 including curing cost of
materials, labour, complete as per specifications. Specifications No. KBS
24.2.1 (PWD SR2011-12/P.No. 137/16.37)
16.37.1 KSRB 24.42 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:6 including curing cost of
materials, labour, complete as per specifications. Specifications No. KBS Sqm 91.50
24.2.1 (PWD SR2011-12/P.No. 137/16.37.1)

16.37.2 KSRB 24.43 : Add from Item No. 24-40, 24-41, 24-42 for every 5mm thick
increase after 10mm with respective mortars including curing cost of
materials, labour, complete as per specifications. (PWD SR2011-12/P.No. Sqm 25.50
137/16.37.2)

16.38 KSRB 24.44 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 184.00
labour, complete as per specifications. Specification No. KBS 24.2.1 (PWD
SR2011-12/P.No. 137/16.38)

16.39 KSRB 24.45 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 165.00
labour, complete as per specifications. Specification No. KBS 24.2.1 (PWD
SR2011-12/P.No. 138/16.39)

16.40 KSRB 24.46 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:6 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 145.00
labour, complete as per specifications. Specification No. KBS 24.2.1 (PWD
SR2011-12/P.No. 138/16.40)

16.41 Removing of existing old or broken wash basin/ urinals and disposing it
with all cost and conveyance labour for all items of work, HOM of
equipment with all lead and lift, loading and unloading, transportation
charges and all other incidental charges etc., complete as per specification Each 111.00
and directions of the Engineer-in-charge of the work. (PWD SR2011-
12/P.No. 138/16.41)

16.42 Removing of existing old or broken Water closet Indian/ European and
disposing it with all cost and conveyance labour for all items of work, HOM
of equipment with all lead and lift, loading and unloading, transportation
charges and all other incidental charges etc., complete as per specification Each 133.00
and directions of the Engineer-in-charge of the work. (PWD SR2011-
12/P.No. 138/16.42)
16.43 Removing of existing old Sanitary and plumbing pipelines, stacking and
disposing it with all cost and conveyance labour for all items of work, HOM
of equipment with all lead and lift, loading and unloading, transportation
charges and all other incidental charges etc., complete as per specification m 44.50
and directions of the Engineer-in-charge of the work. (PWD SR2011-
12/P.No. 138/16.43)

16.44 External Sweeping and terrace Cleaning


Cleaning of outer periphery like roads, footpaths, kerb stones, terrace
including removing grass dust etc., to the nearest garbage pit using
suitable coconut broom stick, bombay broom stick, Sqm 0.50
squeezers/wipers/rubber brushes, coir brushes, bamboo baskets,plastic
buckets, mugs, trolley etc., complete (PWD SR2011-12/ P.No.138, I-
16.44)

16.45 Cleaning stone parapets removing of dirt dust etc., using suitrable soap
powder, coconut broomstick, squeezers/ wipers/ rubber brushes, coir
brushes, plastric brushes,mugs, booster pumps with portable Sqm 1.00
arrangement, hose pipe etc., complete including cost of water charges and
electrical charges. (PWD SR2011-12/ P.No.138, I- 16.45)

16.46 Cleaning Quadrangle chajjas including removing of dirt dust etc., using
suitrable soap powder, coconut broomstick, squeezers/ wipers/ rubber
brushes, coir brushes, plastric brushes,mugs, booster pumps with portable
arrangement, hose pipe etc., complete excluding water charges and Sqm 5.00
electrical charges and all safely measures. (PWD SR2011-12/ P.No.138, I-
16.46)

16.47 Cleaning sub surface drain including removing of dirt dust etc., using
suitrable soap powder, coconut broomstick, squeezers/ wipers/ rubber
brushes, coir brushes, plastric brushes,mugs, booster pumps with portable
m 8.00
arrangement, hose pipe etc., complete (PWD SR2011-12/ P.No.138, I-
16.47)

16.48 Cleaning surface drains including removing of dirt dust etc., using
suitrable soap powder, coconut broomstick, squeezers/ wipers/ rubber
brushes, coir brushes, plastric brushes,mugs, booster pumps with portable
m 5.00
arrangement, hose pipe etc., complete (PWD SR2011-12/ P.No.139, I-
16.48)

16.49 Cleaning of office floors, toilet floors, corridors, lobbies,partitions, storage


units, furnitures, electrical & electronic equipments, doors, windows,
curtains, blinds etc., including cleaning of dust, etc., using suitable bombay
broom stick, sqeezers/ wipers/ rubber brushes, mop sticks, coir brushes,
Sqm 1.00
bamboo baskets, trolleys, wiping cloths, carry bags, etc., removing the
debris to the nearest garbage pit complete. (PWD SR2011-12/ P.No.139,
I- 16.49)
ROADS AND BRIDGES - CARRIAGE OF MATERIALS
17.1 KSRRB M 100-1 Loading and Unloading of Stone Boulder/Stone
aggregates/Sand/Kanker/Moorum.
Placing tipper at loading point, loading with front end
leader,dumping,turninig for return trip, excluding time for haulage and cum 62.60
return trip complete as per specifications. MORTH Chapter 1 Specification
No. KBS 24.2.1 (PWD SR2011-12/P.No. 141/17.1)

17.2 KSRRB M 100-2 Loading and Unloading of Stone Boulders by Manual


Means complete as per Specification No. KBS 24.2.1 (PWD SR2011- cum 73.95
12/P.No. 141/17.2)

17.3 KSRRB M 100-3 Loading and Unloading of Cement Steel by Manual


Means complete as per Specification No. KBS 24.2.1 (PWD SR2011- Tonne 103.70
12/P.No. 141/17.3)

17.4 KSRRB M 100-4.1 Cost of Haulage Excluding Loading and Unloading


MORTH Chapter 1 Specification No. KBS 24.2.1 (PWD SR2011-12/P.No. t.km 2.00
141/17.4)

17.5 KSRRB M 100-4.2 Haulage of materials by tripper excluding cost of


loading, unloading and stacking complete as per specification No. KBS t.km 2.40
24.2.1 (PWD SR2011-12/P.No. 141/17.5)

17.6 KSRRB M 100-4.3 Haulage of materials by tripper excluding cost of


loading, unloading and stacking complete as per specification MORTH No. t.km 4.80
KBS 24.2.1 (PWD SR2011-12/P.No. 141/17.6)

17.7 KSRRB M 100-5 Supply of quarried stone, hand breaking into coarse
aggregate 63mm nominal size (passing 80mm and retained on 50mm
sieve) and stacking as directed complete as per specification No. KBS cum 807.00
24.2.1 (PWD SR2011-12/P.No. 141/17.5)

17.8 KSRRB M 100-6 Crushing of stone boulders of 150 mm size in an


integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyer and vibrating
screens to obtain stone aggregates of 13.2 mm nominal size complete. cum 630.00
MORTH Chapter 1 as per specification No. KBS 24.2.1 (PWD SR2011-
12/P.No. 141/17.8)

17.9 KSRRB M 100-7 Crushing of stone boulders of 150 mm size in an


integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyer and vibrating
screens to obtain stone aggregates of 20 mm nominal size complete. cum 564.00
MORTH Chapter 1 as per specification No. KBS 24.2.1 (PWD SR2011-
12/P.No. 141/17.9)
17.10 KSRRB M 100-8 Crushing of stone boulders of 150 mm size in an
integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyer and vibrating
screens to obtain stone aggregates of 40 mm nominal size complete. cum 504.00
MORTH Chapter 1 as per specification No. KBS 24.2.1 (PWD SR2011-
12/P.No. 141/17.10)
ROADS AND BRIDGES - SITE CLEARANCE AND DISMANTLING
Sl. No. Description Unit Rate

18.1 KSRRB -200-1.1 : Cutting of trees girth from 300mm to 600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres, earth filling in the depressions/ pit,
labour charges complete as per specifications. Specification No. KRBS Each 134.35
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.1)

18.2 KSRRB -200-1.2 : Cutting of trees girth from 600mm to 900mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS
Each 268.65
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.2)

18.3 KSRRB -200-1.3 : Cutting of trees girth from 900mm to 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 671.00
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.3)

18.4 KSRRB -200-1.4 : Cutting of trees girth from 1800mm to 2700mm


including cutting of trunks, branches and removal of stumps stacking of
serviceable materials within a lead of 100 metres and earth filling in the
depressions/ pit, labour charges complete as per specifications. Each 1119.00
Specification No. KRBS 200-1, MORT & H Specification No. 201. (PWD
SR2011-12/P.No.143/18.4)

18.5 KSRRB -200-1.4 : Cutting of trees girth from above 2700mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 100 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS 2686.00
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.5)

18.6 KSRRB -200-1.5 : Cutting of trees girth from 300mm to 600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 156.00
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.6)

18.7 KSRRB -200-1.5 : Cutting of trees girth from 600mm to 900mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 266.00
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.7)
18.8 KSRRB -200-1.5 : Cutting of trees girth from 900mm to 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 538.00
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.8)

18.9 KSRRB -200-1.5 : Cutting of trees girth from above 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials within a lead of 1000 metres and earth filling in the depressions/
pit, labour charges complete as per specifications. Specification No. KRBS Each 1038.00
200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.9)

18.10 KSRRB -200-2.1 : Clearing grass and removal of rubbish by manual


means upto a distance of 50 metres outside th periphery of the area
cleaned labour charges complete as per specifications. Specification No. Ha 11527.00
KRBS 200-1, MORT & H Specification No. 201. (PWD SR2011-
12/P.No.143/18.10)

18.11 KSRRB -200-8 : Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300mm,
by manual means, in area of light jungle, removal of stumps, disposal of
unserviceable materials, stacking of serviceable materials within a lead of
Sqm 4.50
100 metres from road boundary, lablour charges complete as per
specifications. Specification No. KRBS 200-1, MORT & H Specification
No. 201. (PWD SR2011-12/P.No.143/18.11)

18.12 KSRRB -200-9 : Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300mm,
by manual means, in area of thorny jungle, removal of stumps, disposal
of unserviceable materials, stacking of serviceable materials within a lead Sqm 6.70
of 100 metres from road boundary, lablour charges complete as per
specifications. Specification No. KRBS 200-1, MORT & H Specification
No. 201. (PWD SR2011-12/P.No.143/18.12)

18.13 KSRRB -200-3.3 : Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, by machanical means, in area of light jungle and thorny jungle,
removal of stumps, disposal of unserviceable materials, stacking of
serviceable materials within a lead of 1000 metres including removal and
disposal of top organic soil not exeeding 150mm in thickness comlete as Ha 34777.00
per specifications. In area of light jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2011-12/P.No.143/18.13)

18.14 KSRRB M 200-10.2 Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, removal of stumps, of trees cut earlier and disposal of
unserviceable materials, stacking of serviceable materials to be used or
auctioned, up to a lead of 1000 metres including removal and disposal of Ha 46499.00
top organic soil not exeeding 150mm in thickness comlete as per
specifications. In area of thorny jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2011-12/P.No.143/18.14)
18.15 KSRRB M 200-10.2 Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, removal of stumps, of trees cut earlier and disposal of
unserviceable materials, stacking of serviceable materials to be used or
auctioned, up to a lead of 1000 metres including removal and disposal of
Ha 19896.00
top organic soil not exeeding 150mm in thickness comlete as per
specifications. In area of thorny jungle Specification No. KRBS 200-1,
MORTH & H Specification No. 201. (PWD SR2011-12/P.No.144/18.15)In
area of light jungle

18.16 KSRRB M 200-11.2 Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees of girth upto
300mm, removal of stumps, of trees cut earlier and disposal of
unserviceable materials, stacking of serviceable materials to be used or
auctioned, up to a lead of 1000 metres including removal and disposal of
top organic soil not exeeding 150mm in thickness comlete as per
specifications. In area of thorny jungle Specification No. KRBS 200-1, Ha 24210.00
MORTH & H Specification No. 201. (PWD SR2011-12/P.No.144/18.14) In
area of thorny jungle

18.17 KSRRB M200-Dismantling of structures


KSRRB -200-12.1: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 226.00
metres complete as per specifications. i) Lime/Cement Concrete. I.By
Manual meance: A. Lime Concrete, cement concrete grade M-10 and
below Morth Specification No. KRBS 200-2, MORT & H Specification No.
202. (PWD SR2011-12/P.No.144/18.17)

18.18 KSRRB -200-12.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. i) Lime/Cement Concrete. I.By cum 272.00
Manual meance: B. Cement Concrete grade. cement concrete grade M-15
& M-20 and below Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.144/18.18)

18.19 KSRRB -200-12.3: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. i) Lime/Cement Concrete. I.By cum 733.00
Manual meance: C. Prestressed/Reinforced cement concrete grade M-20
and above Specification No. KRBS 200-2, MORT & H Specification No.
202. (PWD SR2011-12/P.No.144/18.19)
18.20 KSRRB -200-13.1: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. ii) By Mechanical meance. A. cum 300.00
Cement Concrete. I.By Manual meance: C. Prestressed/Reinforced
cement concrete grade M-15 & M-20 and above Specification No. KRBS
200-2, MORT & H Specification No. 202. (PWD SR2011-
12/P.No.144/18.20)

18.21 KSRRB -200-13.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. ii) By Mechanical meance. A. cum 505.00
Cement Concrete. I.By Manual meance: C. Prestressed/Reinforced
cement concrete grade M-15 & M-20 and above Specification No. KRBS
200-2, MORT & H Specification No. 202. (PWD SR2011-
12/P.No.144/18.21)

18.22 KSRRB -200-14.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 134.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. A.
In lime morter.Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.144/18.22)

18.23 KSRRB -200-14.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 180.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. B.
In cement morter.Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.144/18.23)

18.24 KSRRB -200-14.3: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 116.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. C.
In mud morter.Morth Specification No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.144/18.24)
18.25 KSRRB -200-14.4: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 90.00
metres complete as per specifications. ii)Dismanting Brick / Tile work. D.
Dry brick pitching or brick soiling orter.Morth Specification No. KRBS 200-
2, MORT & H Specification No. 202. (PWD SR2009-10/P.No.120/18.25)

18.26 KSRRB -200-15.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 153.00
metres complete as per specifications. ii)Dismanting Stone Masonry. A.
Rubble Stone masonry in lime mortar..Morth Specification No. KRBS 202
(PWD SR2011-12/P.No.144/18.26)

18.27 KSRRB -200-15.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 180.00
metres complete as per specifications. ii)Dismanting Stone Masonry. B.
Rubble Stone masonry in cement mortar..Morth Specification No. KRBS
202 (PWD SR2011-12/P.No.145/18.27)

18.28 KSRRB -200-15.3: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 134.00
metres complete as per specifications. ii)Dismanting Stone Masonry. C.
Rubble Stone masonry in mud mortar..Morth Specification No. KRBS 202
(PWD SR2011-12/P.No.145/18.28)

18.29 KSRRB -200-15.4: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 125.00
metres complete as per specifications. ii)Dismanting Stone Masonry. D.
Dry rubble masonry Morth Specification No. KRBS 202 (PWD SR2011-
12/P.No.145/18.29)

18.30 KSRRB -200-15.5: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000 cum 115.00
metres complete as per specifications. ii)Dismanting Stone Masonry. E.
Dismanting stone pitching/dry stone spalls. Morth Specification No. KRBS
202 (PWD SR2011-12/P.No.145/18.30)
18.31 KSRRB -200-15.6: Dismantling of existing structures like culverts, bridges,
retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. ii)Dismanting brick tile work. F. cum 134.00
Dismanting Boulders laid in wire crates including opening of crates and
stacking dismantled materials. Morth Specification No. KRBS 202 (PWD
SR2011-12/P.No.145/18.31)

18.32 KSRRB -200-16: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
cum 318.00
metres complete as per specifications. iv)Dismanting wood work wrought
framed and fixed in frames of trusses upto a Height of 5 m above Pilnth
Level. Morth Specification No. KRBS 202 (PWD SR2011-
12/P.No.145/18.32)

18.33 KSRRB -200-17.1: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. v)Steel work in all types of Section Tonne 860.00
upto a Height of 5 m above plinth level excluding Cutting of Rivet.-A.
Including dismembering." Specification No. KRBS 202 (PWD SR2011-
12/P.No.145/18.31)

18.34 KSRRB -200-17.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. v)Steel work in all types of Section Tonne 651.00
upto a Height of 5 m above plinth level excluding Cutting of Rivet.-
A.Excluding dismembering." No. KRBS 202 (PWD SR2011-
12/P.No.145/18.34)

18.35 KSRRB -200-17.2: Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T & P and scaffolding wherever
necessary, sorting the dismantled maerial, disposal of unserviceable
RIVET 6.00
material and stacking the serviceable material with all lifts and lead of 1000
metres complete as per specifications. B for Cutting of Rivets.
Specification No. KRBS 202 (PWD SR2011-12/P.No.145/18.35)

18.36 KSRRB -200-18.1 : vi) Scraping of bricks dismantled from brick work
including Stacking - A.In Lime/Cement mortar. Specification No. KRBS
200-2, MORT & H Specification No. 202. (PWD SR2011- Nos. 0.80
12/P.No.145/18.36)
18.37 KSRRB -200-18.2 : Scraping of bricks dismantled from brick work in mud
mortar and stacking including cost of all labour charges complete as per
specifications. Specification No. KRBS 200-2, MORT & H Specification No. Nos. 0.30
202. (PWD SR2011-12/P.No.145/18.37)
18.38 KSRRB -200-19.1 : Scraping of Stones dismantled from stone masonry in
cement / lime mortar and stacking including cost of all labour charges
complete as per specifications. Specification No. KRBS 200-2, MORT & H Cum 323.00
Specification No. 202. (PWD SR2011-12/P.No.145/18.38)
18.39 KSRRB -200-19.2 : Scraping of Stones dismantled from stone masonry in
mud mortar and stacking including cost of all labour charges complete as
per specifications. Specification No. KRBS 200-2, MORT & H Specification Cum 68.75
No. 202. (PWD SR2011-12/P.No.145/18.39)
18.40 KSRRB -200-20 : Scrapping plaster in lime or cement mortar from
brick/stone masonry. as per specifications. Specification No. KRBS 200-2, Sqm 9.85
MORT & H Specification No. 202. (PWD SR2011-12/P.No.145/18.40)
18.41 KSRRB -200-21.1 : Removing all types of hume pipes and stacking within
a lead of 1000 metres including earthwork and dismanting of masonary
works.A. Upto 600 mm dia. Specification No. KRBS 200-2, MORT & H m 119.00
Specification No. 202. (PWD SR2011-12/P.No.145/18.41)

18.42 KSRRB -200-21.2 : Removing all types of hume pipes and stacking within
a lead of 1000 metres including earthwork and dismanting of masonary
works.B. Above 600 mm to 900 mm dia. Specification No. KRBS 200-2, m 161.00
MORT & H Specification No. 202. (PWD SR2011-12/P.No.145/18.42)

18.43 KSRRB -200-21.3 : Removing all types of hume pipes and stacking within
a lead of 1000 metres including earthwork and dismanting of masonary
works.C. Above 900 mm dia. Specification No. KRBS 200-2, MORT & H m 277.00
Specification No. 202. (PWD SR2011-12/P.No.145/18.43)

18.44 KSRRB -200-22.1 : Dismanting of flexible pavements and disposal of


dismantled materials upto a lead of 1000 metres, stacking serviceable and
unserviceable materials seperately complete as per Specification. A. cum 419.00
Bituminous courses. No. KRBS 200-2, MORT & H Specification No. 202.
(PWD SR2011-12/P.No.145/18.44)
18.45 KSRRB -200-22.2 : Dismanting of flexible pavements and disposal of
dismantled materials upto a lead of 1000 metres, stacking serviceable and
unserviceable materials seperately complete as per Specification. A. cum 294.00
Granular courses. No. KRBS 200-2, MORT & H Specification No. 202.
(PWD SR2011-12/P.No.146/18.45)
18.46 KSRRB -200-23.1 : Dismanting of flexible pavements and disposal of
dismantled materials upto a lead of 1000 metres, stacking serviceable and
unserviceable materials seperately complete as per Specification. cum 148.30
Mechanical Meance A. Bituminous courses. No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.146/18.46)
18.47 KSRRB -200-24 : Dismanting of cement concrete pavement by
mechanical meance using penumatic tools, breaking to pieces not
exceeding 0.02 cum in volume and stock piling at designated locations and
disposal of dismantled materials upto a lead of 1000 metres, stacking
serviceable and unserviceable materials seperately complete as per cum 644.00
Specification. No. KRBS 200-2, MORT & H Specification No. 202. (PWD
SR2011-12/P.No.146/18.47)
18.48 KSRRB -200-25 : Dismanting of guard rails by manual means and
disposal of dismantled materials with all lifts and upto a lead of 1000
metres, stacking serviceable materials and unserviceable materials m 44.30
seperately complete as per Specification. No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.146/18.48)

18.49 KSRRB -200-26: Dismanting kerb stone by manual means and disposal
of dismantled materials with all lifts and upto a lead of 1000 metres,
complete as per Specification. No. KRBS 200-2, MORT & H Specification m 7.45
No. 202. (PWD SR2011-12/P.No.146/18.49)

18.50 KSRRB -200-27 : Dismanting kerb stone channel by manual means


including and disposal of dismantled materials with all lifts and upto a
lead of 1000 metres, complete as per Specification. No. KRBS 200-2, m 11.15
MORT & H Specification No. 202. (PWD SR2011-12/P.No.146/18.50)

18.51 KSRRB -200-28.1 : Dismanting of kilometre stone including cutting of


earth, foundation and disposal of dismantled materials with all lifts and
upto a lead of 1000 metres, and back filling of pit complete as per
Specification. A. 5th KM stone (quantity of cement concrete = 0.392 cum ) Each 224.00
No. KRBS 200-2, MORT & H Specification No. 202. (PWD SR2011-
12/P.No.146/18.51)

18.52 KSRRB -200-28.2 : Dismanting of kilometre stone including cutting of


earth, foundation and disposal of dismantled materials with all lifts and
upto a lead of 1000 metres, and back filling of pit complete as per
Specification. B. Ordinary KM stone (quantity of cement concrete = 0.269 Each 134.75
cum ) No. KRBS 200-2, MORT & H Specification No. 202. (PWD SR2011-
12/P.No.146/18.52)

18.53 KSRRB -200-28.3 : Dismanting of kilometre stone including cutting of


earth, foundation and disposal of dismantled materials with all lifts and
upto a lead of 1000 metres, and back filling of pit complete as per
Specification. B. Hectometre stone (quantity of cement concrete = 0.048 Each 27.00
cum ) No. KRBS 200-2, MORT & H Specification No. 202. (PWD SR2011-
12/P.No.146/18.53)

18.54 KSRRB -200-29: Dismanting of barbed wire fencing / wire mesh fencing
including posts, foundation concrete, back filling of pit by manual meance
including disposal of dismantled materials with all lifts and upto a lead of
1000 metres, stacking serviceable materials and unserviceable materials m 29.80
seperately complete as per Specification.No. KRBS 200-2, MORT & H
Specification No. 202. (PWD SR2011-12/P.No.146/18.54)

18.55 KSRRB M200-30. Dismanting of CI water pipe line 600 mm dia including
disposal with all lifts and lead of 1000 metres, and stacking serviceable
materials and unserviceable material seperately under supervision of
m 73.65
concerned department complete as per Specification.No. KRBS 200-2,
MORT & H Specification No. 202. (PWD SR2011-12/P.No.147/18.55)

18.56 KSRRB M200-31. Removal of cement concrete pipe of sewer gutter 1500
mm dia under the supervision of concerned department including
disposal with all lifts and up to lead of 1000 metres, and stacking
serviceable materials and unserviceable material seperately but excluding
m 100.80
earth excavation and dismantling of masonry work complete as per
Specification.No. KRBS 200-2, MORT & H Specification No. 202. (PWD
SR2011-12/P.No.147/18.56)
18.57 KSRRB M200-32. Removal of Telephone / Electric poles including
excavation and dismantling of foundation concrete and lines under the
supervision of concerned department, disposal with all lifts and up to lead
of 1000 metres, and stacking serviceable materials and unserviceable
Nos 101.90
material seperately complete as per Specification.No. KRBS 200-2,
MORT & H Specification No. 202. (PWD SR2011-12/P.No.147/18.57)
EARTH WORK FOR ROADS
2008-2009
Sl. Description Rate
No. Unit
Rs. Ps.
19.0 EARTH WORK , EROSION AND DRAINAGE
Cum 58.20
KSRRB 300 - Excavation for road, drains and similar works

19.1 KSRRB -300-1.2 : Earthwork excavation by manual means in ordinary soil


involving an average horizontal throw upto 2 meters and an average lift
upto 0.5m, excavated surface levelled and sides neatly dressed, the
disposed earth to be levelled neatly, after breaking of clods complete as
per specifications. MORTH / Chapter
3 (PWD SR2011-12/P.No.149/19.1)

19.2 KSRRB -300-1.2 : Earthwork excavation by manual means in hard soil


involving an average horizontal throw upto 2 meters and an average lift
upto 0.5m, excavated surface levelled and sides neatly dressed, the
disposed earth to be levelled neatly, after breaking of clods complete as Cum 80.60
per specifications. Specification No. KRBS 300-1, MORT & H
Specification No. 301 to 305. (PWD SR2011-12/P.No.149/19.2)

19.3 KSRRB -300-3 : Earth excavation and Formation of road embankment by


manual means ordinary soil with initial lead upto 15 m and lift of 1.5 m
(when earth is taken from bank cutting or from borrow pits ) including
breaking of clods, spreading to required line and level, forming and cost of
Cum 73.90
all labour complete as per specifications. (excluding watering and
compaction of earth) Specification No. KRBS 300-1, 300-5 MORT & H
Specification No. 301 to 305. (PWD SR2011-12/P.No.149/19.3)

19.4 KSRRB -300-3 : Earth excavation and Formation of road embankment by


manual means hard soil with initial lead upto 15 m and lift of 1.5 m (when
earth is taken from bank cutting or from borrow pits ) including breaking of
clods, spreading to required line and level, forming and cost of all labour Cum 112.00
complete as per specifications. (excluding watering and compaction of
earth) Specification No. KRBS 300-1, 300-5 MORT & H Specification No.
301 to 305. (PWD SR2011-12/P.No.149/19.4)
19.5 KSRRB -300-5 : Excavation in soft rock with blasting for formation of
roads including stacking neatly, to uniform line and level with an initial lead
upto 15m. cost of explosives, labour, HOM of machineries and equipments
complete as per specifications. Specification No. KRBS 300-1, 300-5, Cum 263.00
MORT & H Specification No. 301 to 305. (PWD SR2011-
12/P.No.149/19.5)

19.6 KSRRB -300-2.4 : Excavation in soft rock without blasting for formation
of roads including stacking neatly, to uniform line and level with an initial
lead upto 15m. cost of all labour, equipment, complete as per Cum 532.00
specifications. Specification No. KRBS 300-1, 300-5, MORT & H
Specification No. 301 to 305. (PWD SR2011-12/P.No.149/19.6)
19.7 KSRRB -300-7: Excavation in hard rock by blasting for formation of roads
including stacking to uniform line and level with an initial lead upto 15m.
and lift upto 1.5m, as directed by the engineer including cost of explosives,
labour, HOM of machineries and equipments complete as per Cum 358.00
specifications. Specification No. KRBS 300-1, 300-2, MORT & H
Specification No. 302 (PWD SR2011-12/P.No.149/19.7)

19.8 KSRRB -300-8 : Excavation in hard rock by chiselling and / or wedging


where blasting is prohibited for formation of roads including stacking to
uniform line and level with an initial lead upto 15m. cost of all labour Cum 801.60
complete as per specifications. Specification No. KRBS 300-1, MORT & H
Specification No. 305 (PWD SR2011-12/P.No.125/19.8)
19.9 KSRRB -300-9 : Excavation for roadway in soil using manual means
including loading in truck for carrying of cut earth to embankment site with
all lifts and lead upto 1000 metres Complete as per specifications. KSRB Cum 110.45
300-1 MORTH Specification No. 301 to 305 (PWD SR2011-
12/P.No.149/19.9)
19.1 KSRRB -300-10 : Excavation in ordinary rock using manual means
including loading in truck and carrying of excavated material to
embankment site with all lifts and lead upto 1000 metres Complete as per cum 158.50
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2011-12/P.No.149/19.10)
Excavation in Soil with Dozer with lead upto 100 metres.
19.11 KSRRB -300-11 : Excavation for roadway in soil by mechanical means
including cutting and pushing the earth to site of embankment upto a
distance of 1000 metres (average lead 50 metres) including trimming
bottom and side slopes in accordance with requirements of lines, grade cum 65.15
and cross sections Complete as per specifications. KSRB 300-1 MORTH
Specification No. 301 (PWD SR2011-12/P.No.150/19.11)

Excavation in Ordinary Rock with Dozer with lead upto 100 metres
19.12 KSRRB -300-12 : Excavation for roadway in ordinary rock by deploying a
dozer, 80 HP including cutting and pushing the cut earth to site of
embankment upto a distance of 100 metres (average lead 50 metres)
trimming bottom and side slopes in accordance with the requirements of cum 110.75
lines, grades and cross sections Complete as per specifications. KSRB
300-1 MORTH Specification No. 301 (PWD SR2011-12/P.No.150/19.12)

Excavation in Hard Rock (requiring blasting) with disposal upto 1000


metres
19.13 KSRRB M300-13 : Excavation for roadway in hard rock by (requiring
blasting) by drilling, blasting and breaking, trimming of bottom and side
slopes in accordance with the requirements of lines, grades and cross
sections, loading and disposal of cut road with in all lifts and leads upto cum 96.65
1000 metres Complete as per specifications. KSRB 300-1 MORTH
Specification No. 301 (PWD SR2011-12/P.No.150/19.13)

Excavation in Soil using Hydraulic Excavation CK 90 and Tippers


with Disposal upto 1000 metres
19.14 KSRRB -300-14 : Excavation for roadway in soil with hydraulic excavator
of 0.9 cum bucket capacity including cutting and loading in tippers
trimming bottom and side slopes in accordance with the requirements of
lines, grades and cross sections, and transporting to the embankment cum 34.25
location with in all lifts and leads upto 1000 metres Complete as per
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2011-12/P.No.150/19.14)

Excavation in Ordinary Rock using Hydraulic Excavator CK-90 and


Tippers with Disposal upto 1000 metres.
19.15 KSRRB -300-15 : Excavation for roadway in ordinary rockl with hydraulic
excavator of 0.9 cum bucket capacity including cutting and loading in
tippers transporting to the embankment site with in all lifts and leads upto
1000 metres trimming bottom and side slopes in accordance with cum 45.35
requirements of lines, grades and cross sections Complete as per
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2011-12/P.No.150/19.15)

Excavation in Hard Rock (blasting prohibited)


19.16 KSRRB -300-16.1 : Excavation for roadway in hard rock by ( blasting
prohibited) with Rock breakers including breaking rock, loading in tippers
and disposal within all lifts and leads upto 1000 metres trimming bottom
and side slopes in accordance with requirements of lines, grades and cum 239.65
cross sections Complete as per specifications. A. Mechanised KSRB 300-
1 MORTH Specification No. 301 (PWD SR2011-12/P.No.150/19.16)

Excavation in Hard Rock (blasting prohibited)


19.17 KSRRB -300-16.2 : Excavation for roadway in hard rock by ( blasting
prohibited) with Rock breakers including breaking rock, loading in tippers
and disposal within all lifts and leads upto 1000 metres trimming bottom
and side slopes in accordance with requirements of lines, grades and cum 565.00
cross sections Complete as per specifications. B. Manual Method. KSRB
300-1 MORTH Specification No. 301 (PWD SR2011-12/P.No.151/19.17)

19.18 KSRRB -300-17 : Excavation for roadway in hard rock ( controlled blasting
) with Rock breakers including breaking rock, loading in tippers
trancporting to embankment site within all lifts and leads upto a distance
of 1000 metres trimming bottom and side slopes in accordance with cum 122.30
requirements of lines, grades and cross sections Complete as per
specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2011-12/P.No.151/19.18)

Excavation in Marshy Soil


19.19 KSRRB -300-18 : Excavation for roadway in marshy soil with hydraulic
excavator of 0.9 cum bucket capacity including cutting and loading in
tippers and disposal with in all lifts and leads upto 1000 metres trimming
bottom and side slopes in accordance with requirements of lines, grades cum 38.80
and cross sections Complete as per specifications. KSRB 300-1 MORTH
Specification No. 301 (PWD SR2011-12/P.No.151/19.19)
Removal of Unserviceable Soil with Disposal upto 1000 metres.
19.20 KSRRB -300-19 : Removal of Unserviceable soil including excavation,
loading and disposal upto 1000 metres lead but excluding replacement by
suitable soil which shall be paid separately as per clause 300.5 Complete cum 34.55
as per specifications. KSRB 300-1 MORTH Specification No. 301 (PWD
SR2011-12/P.No.151/19.20)

Presplitting of Rock Excavation Slopes.


19.21 KSRRB -300-20 :Carrying out excavation in hord rock to achieve a
specified slope of the rock face by controlled use of explosives and
blasting accessories in properly aligned and spaced drill holes, collection
of the excavated rock by a 80 HP dozer,loading in tripper by a front end
loader and disposing of the material with all lifts and lead upto 1000m, all Sqm 77.35
as specified in clause No. 300.3 Complete as per specifications. KSRB
300-1 MORTH Specification No. 303 (PWD SR2011-12/P.No.151/19.21)

Excavation for Structures.


19.22 KSRRB -300-21.1 : Earth work in excavation of foundation of structures as
per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 184.45
as per specifications. i) Ordinary Soil-A. Manual Means (i) Depth upto 3m
KSRB 300-1 MORTH Specification No. 304 (PWD SR2011-
12/P.No.151/19.22)

19.23 KSRRB -300-21.2 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 30.35
as per specifications. i) Ordinary Soil-A. Mechanical Means (i) Depth upto
3m KSRB 300-1 MORTH Specification No. 304 (PWD SR2011-
12/P.No.151/19.23)

19.24 KSRRB -300-22.1 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 230.55
as per specifications. ii) Ordinary Rock (not requiring blasting) -A.Manual
Means (i) Depth upto 3m KSRB 300-1 MORTH Specification No. 304
(PWD SR2011-12/P.No.152/19.24)
19.25 KSRRB -300-22.2 : Earth work in excavation of foundation of structures as
per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 40.00
as per specifications. ii) Ordinary Rock (not requiring blasting)
-B.Mechanicall Means (i) Depth upto 3m KSRB 300-1 MORTH
Specification No. 304 (PWD SR2011-12/P.No.152/19.25)

19.26 KSRRB -300-23 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete
cum 378.00
as per specifications. ii) Hord Rock (requiring blasting) -A.Manual Means
(i) Depth upto 3m KSRB 300-1 MORTH Specification No. 304 (PWD
SR2011-12/P.No.152/19.26)

19.27 KSRRB -300-24 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 423.00
as per specifications. iv) Hord Rock ( blasting prohibited) -A.Mechanical
Means KSRB 300-1 MORTH Specification No. 304 (PWD SR2011-
12/P.No.152/19.27)

19.28 KSRRB -300-25.2 : Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 300.00
as per specifications. v) Marshy Soil A.Mechanical Means i) upto 3m
depth KSRB 300-1 MORTH Specification No. 304 (PWD SR2011-
12/P.No.152/19.28)

19.29 KSRRB -300-25.3: Earth work in excavation of foundation of structures as


per drawing and technical specification, including setting out, construction
of shorting and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom, backfilling the excavation earth to the extent
required and utilising the remaining earth locally for road work Complete cum 79.65
as per specifications. vi) Marshy Soil B.Mechanical Means i) upto 3m
depth KSRB 300-1 MORTH Specification No. 304 (PWD SR2011-
12/P.No.152/19.29)

KSRRB 300-Extra additional lead


19.30 KSRRB -300-26.1: Extra for every 7.5 m additional lead beyond 15m but
upto 60m by manual means for all kinds of soils except hard rock including
cost of all labour complete as pwe specifications KSRB 300-1 MORTH cum 2.50
Specification No. 304 (PWD SR2011-12/P.No.152/19.30)
19.31 KSRRB -300-26.2: When lead is more than 60m upto 500m by any means
of conveyance including loading and unloading for all kinds of soils except
hard rock including cost of all labour complete as per specification. KSRB cum 2.85
300-1 MORTH Specification No. 304 (PWD SR2011-12/P.No.152/19.31)

19.32 KSRRB -300-27: Dressing of earthwork including cutting and filling upto 15
cms thick or depth including cost of all labour complete as per
specification. KSRB 300-1 MORTH Specification No. 304 (PWD cum 29.10
SR2011-12/P.No.152/19.32)

19.33 KSRRB -300-28 : Box cutting / trenching the sub grade to proper slope,
camber and removing inequalities including removing the stuff and
depositing on the road side slopes (cutting of earthwork shall be paid
seperately in the respective item on thebasis of classification of the Sqm 0.70
excavation) including cost of all labour complete as per specifications.
Specification No. KRBS 300-1. MORT & H Specification No. 301 to 305.
(PWD SR2011-12/P.No.152/19.33)

KSRRB M300-Stripping and Storing of top soil


19.34 KSRRB -300-29 : Stripping, Storing of top soil by road side at 15 internal
and re-application on embankment slopes. Cut slopes and other areas in
localities where the aailable ambankment materila is notconducive to plant cum 134.00
growth complete as per specifications. Specification No. Specification No.
301 to 305. (PWD SR2011-12/P.No.152/19.34)

KSRRB M300-Stripping, Storing and Re-laying Top soil from Borrow


Areas in Agriculture Fields.
19.35 KSRRB -300-30 : Stripping, Storing and Re-laying top soil from Borrow
Areas in Agriculture Fields. Stripping of top soil from borrow areas located
in agriculture fields, storing at a suitable place, spreading and re-laying
after taking the borrow earth to maintain fertility of the agricultural field. cum 39.65
finishing it to the required levels and satisfaction of the farmer complete as
per specifications. Specification No. Specification No. 301 to 305. (PWD
SR2011-12/P.No.152/19.35)

KSRRB M300-Turfing with Sods/Seeding and Mulching


19.36 KSRRB -300-31 : Turfing with Sods-Furnishing and laying of the live sods
of perenial turf forming grass on embankment slope, verges or other
locations shown on the drawing or as directed by the Engineer including
preparation of ground, fetching of sods and watering. complete as per Sqm 16.30
specifications. Specification No. Specification No. 301 to 307. (PWD
SR2011-12/P.No.153/19.36)

19.37 KSRRB -300-32 : Preparation of seed bed on previously laid top soil,
furnishing and placing of seeds, fertilizer, mulchjing material, applying
bituminious emulsion at the rate of 0.23 litres per swm and laying and
fixing jutee netting, including watering for 3 months all as per Clause 308 Sqm 60.40
complete as per specifications. Specification No. Specification No. 301 to
308. (PWD SR2011-12/P.No.153/19.37)
KSRRB M300-Surface Drains in Soil/Rock
19.38 KSRRB -300-33.1 : Construction of unlined surface drain of average cross
sectional area 0.40 sqm in soil to specified lines,grades,levels and
dimensions to the requirement of Clauses 300.1 and 300.9. Excavated
material to be used in embankment within a lead of 50 metres (average m 45.70
lead 25 metres) complete as per specifications. A. Mechanical Means
Specification No. Specification No. 309. (PWD SR2011-
12/P.No.153/19.38)

19.39 KSRRB -300-33.2 : Construction of unlined surface drain of average cross


sectional area 0.40 sqm in soil to specified lines,grades,levels and
dimensions to the requirement of Clauses 300.1 and 300.9. Excavated
material to be used in embankment within a lead of 50 metres (average m 46.10
lead 25 metres) complete as per specifications.B. Manual Means
Specification No. Specification No. 309. (PWD SR2011-
12/P.No.153/19.37)

KSRRB M300-34 Surface Drains in Ordinary Rock


19.40 KSRRB -300-34.1 : Construction of unlined surface drain of average cross
sectional area 0.40 sqm in Ordinary rock to specified lines,grades,levels
and dimensions as per approved design and to the requirement of Clauses
300.1 and 300.9. Excavated material to be used in embankment site m 92.55
complete as per specifications. A. Mechanical Means Specification No.
Specification No. 309. (PWD SR2011-12/P.No.153/19.40)

KSRRB M300- Surface Drains in Ordinary Rock


19.41 KSRRB -300-34.2 : Construction of unlined surface drain of average cross
sectional area 0.40 sqm in Ordinary rock to specified lines,grades,levels
and dimensions as per approved design and to the requirement of Clauses
300.1 and 300.9. Excavated material to be used in embankment site m 69.15
complete as per specifications. B. Manual Means Specification No.
Specification No. 309. (PWD SR2011-12/P.No.69.15/19.41)

KSRRB M300- Sub-Surface Drains with Perforated Pipe.


19.42 KSRRB -300-36 : Construction sub-surface drain th perforated pipe of 100
mm internal diametere of metal/asbestos cement/ cement concrete/ PVC,
closely jointed, perforations ranging from 3mm to 6mm depnding upon
size of material surrounding the pipe, with 150mm bedding below the pipe
and 300mm causion above the pipe, cross-section of excavation m 362.00
450x550mm. Excavated material to be utilised in roadway at site complete
as per specifications. MORTH Specification No. Specification No. 309.
(PWD SR2011-12/P.No.153/19.42)

KSRRB M300-Aggregate Sub-Surface Drains.


19.43 KSRRB -300-37 : Construction of aggregate sub-surface drain
300mmx450mm with aggregate conforming to Table 300-4, excavated
material to be utilised in roadway complete as per specifications. MORTH m 124.40
Specification No. Specification No. 309. (PWD SR2011-
12/P.No.154/19.43)
KSRRB M300-Underground Drain at Edge of Pevment .
19.44 KSRRB -300-38 : Construction of Underground Drain 1 m x 1 m (inside
Dimensions) lined with RCC 15 cm thick and covered with RCC slab 10 cm
in thickness on urban Roads ( rates of these itmes may be taken from
chapters on earth work and sub structures respectively) complete as per m 2199.00
specifications. MORTH Specification No. Specification No. 309. (PWD
SR2011-12/P.No.154/19.44)

KSRRB M300-Preparation and surface treatment of formation


19.45 KSRRB -300-39 : Preparation and surface treatment of formation by
removing mud and slurry, watering to the extent needed to maintain the
disired moisture content, trimming to the required line, grade profil and
rolling with 8 - 10 tonne smoth sheeled roller, complete as per Caluse 310. Sqm 1.15
complete as per specifications.MORTH Specification No. 301. (PWD
SR2011-12/P.No.154/19.45)

KSRRB M300- Earth work on Hill Road


19.46 KSRRB -300-40 : Excavation in Hilly areas in soil by mechnical means
excavation soil in hilly areas by mechanical means including cutting and
trimming of side slopes and disposing of excavated eath with all lifts and Cum 79.25
leed up to 1000 meters complete as per specifications.MORTH
Specification No. 301. (PWD SR2011-12/P.No.154/19.46)

19.47 KSRRB -300-41 : Excavation in Hilly areas in Ordinary Rock by mechnical


means not requiring Blasting. excavation in hilly area in Ordinary Rock not
requring blasting by mechanical means including cutting and trimming of
slopes and disposal of cut material with all lifts and leed up to 1000 Cum 119.80
meters complete as per specifications.MORTH Specification No. 301.
(PWD SR2011-12/P.No.154/19.47)

19.48 KSRRB -300-42 : Excavation in Hilly areas in Hard Rock requiring


Blasting. excavation in hilly area in Hard Rock requring blasting by
mechanical means including trimming of slopes and disposal of cut
material with all lifts and leed up to 1000 meters complete as per Cum 228.55
specifications.MORTH Specification No. 301. (PWD SR2011-
12/P.No.154/19.48)

KSRRB M300- Scarifying the surface and dressing


19.50 KSRRB -300-44 : Scarifying top bituminous surface or surface dressing or
premix carpet including picking up scarified materials, stacking of old
serviceabale materials with in lead of 100 m by manual means including Sqm 17.90
cost of all labour charges complete as per specifications.MORTH
Specification No. 301. (PWD SR2011-12/P.No.155/19.50)
19.51 KSRRB -300-45 : Scarifying stone metal crust 50mm to 100mm thick with
pick axes along with premix carpet / surface dressing and stacking of old
serviceable materials with in a lead top bituminous surface or surface
dressing or premix carpet including picking up scarified materials, stacking
of old serviceabale materials with in lead of 100 m by manual means Sqm 35.80
including cost of all labour charges complete as per
specifications.MORTH Specification No. 301. (PWD SR2011-
12/P.No.155/19.51)

19.52 KSRRB -300-46 : Scarifying stone metal crust 50mm to 100mm thick by
road roller with scarifier along with 20mm pre mix corpet / surface dressing
and stacking of old serviceable materials with in a lead of 100 m including
cost of all labour charges complete as per specifications.MORTH Sqm 22.70
Specification No. 301. (PWD SR2011-12/P.No.155/19.52)

19.53 KSRRB -300-47 : Scarifying Kankar / gravel / metal crust up to 150mm


thick with pick axes and disposal of stuff with in a lead of 100 m including
cost of all labour charges complete as per specifications.MORTH Sqm 17.90
Specification No. 301. (PWD SR2011-12/P.No.155/19.53)

19.54 KSRRB -300-48 : Scarifying Kankar / gravel / metal crust up to 150mm


thick with power roller and scarifier disposal of stuff with in a lead of 100 m
including cost of all labour charges HOM, of machineries complete as per Sqm 13.60
specifications.MORTH Specification No. 301. (PWD SR2011-
12/P.No.155/19.54)

19.55 KSRRB -300-49 : Scarifying bituminous course 50mm to 75mm thick along
with premix carpet / surface dressing by manula means with out disturbing
the base and stacking of the debries materils with in a lead of 100 m
including cost of all labour charges complete as per specifications.MORTH Sqm 40.30
Specification No. 301. (PWD SR2011-12/P.No.155/19.55)

19.56 KSRRB -300-50 : Scarifying bituminous course 50mm to 75mm thick along
with premix carpet / surface dressing by road roller attached with scarifier
with out disturbing the base and stacking of the debries with in a lead of
100 m including cost of all labour charges HOM, of machineries complete Sqm 22.70
as per specifications.MORTH Specification No. 301. (PWD SR2011-
12/P.No.155/19.56)

19.57 KSRRB -300-51 : Making 50mm x 50mm furrows at 450 to the centre line
of the road and at 1m interval in the existing thin bituminous wearing
course including sweeping taking out old materials stacking the debries
with in a lead of 100 m cost of all labour charges complete as per Sqm 2.15
specifications.MORTH Specification No. 301. (PWD SR2011-
12/P.No.155/19.57)
KSRRB M300-Scarifying Existing Granular Surface to a Depth of 50
mm by Manual Means
19.58 KSRRB -300-52.1 :Scarifying the existing granular road surface to a depth
of 50 mm and disposal of scarified materials within all lifts and leads upto
1000 m complete as per specifications.MORTH Specification No. 305.4.3. Sqm 14.75
(PWD SR2011-12/P.No.156/19.58)

19.59 KSRRB -300-52.2 :Scarifying the existing bituminious suface to a depth of


50 mm by mechanical means surfacing the existing Bituminious road
surface to a depth of 50 mm and disposal of scarified materials within all Sqm 2.90
lifts and leads upto 1000 m complete as per specifications.MORTH
Specification No. 305.4..3. (PWD SR2011-12/P.No.156/19.59)

KSRRB M300-Construction of Embankment with material gravel /


murrum

19.60 KSRRB -300-53 : Construction of Embankment with approved Material


gravel / murrum with all lifts and leads, transporting to site, spreading,
gradding to required slobe and compacting to meet requirement table 300-
2 complete as per specifications (with includes cost of gravel / murrum, Sqm 136.00
watering charges and compacation by vibratory roller) .MORTH
Specification No. 305(PWD SR2011-12/P.No.156/19.60)

KSRRB M300-Construction of Embankment with material deposited


from roadway cutting .
19.61 KSRRB -300-54 : Construction of Embankment with approved Material
deposited at site from roadway cutting and excavation fro drain and
foundation of other structures graded and compacted to meet requirement
of table 300-2 complete as per specifications (with includes watering Cum 62.75
charges and compacation by vibratory roller) .MORTH Specification No.
305(PWD SR2011-12/P.No.156/19.61)

KSRRB M300- Construction of Sub grade & Earthen Shoulders.

19.62 KSRRB -300-55 : Construction of Sub grade & earthen shoulders material
gravel / murrum with all lifts and leads transporting to site, spreading,
grading to required slope and compacted to meet requirement, of table No.
300-2 complete as per specifications ( including cost of Cum
earth, watering charges and compacation by vibratory roller) .MORTH
Specification No. 305(PWD SR2011-12/P.No.156/19.62)

KSRRB M300-Constructio of Rock fill Embankment.


19.63 KSRRB -300-56 : Construction of Rock fill Embankment with available
broken hard Rock fragments of size not exceeding 300mm laid in layers
not exceeding 500 mm thick including filling of surface voids with stone
spalls, blinding top layers with granular material, rolled with vibratory road
roller, all complete as per clause 313 complete as per specifications Cum 35.55
( including cost of earth, watering charges and compacation by vibratory
roller) .MORTH Specification No. 313(PWD SR2011-12/P.No.156/19.63)

KSRRB M300-Compaction

19.64 KSRRB -300-58 : Compaction of original ground with maximum of 6


passes of 8 to 10 tonnes power roller including filling in depression
occuring during rolling including cost of all labour HOM of machinery Cum 3.65
complete as per specifications. .MORTH Specification No. 305 (PWD
SR2011-12/P.No.157/19.64)

19.65 KSRRB -300-59.1 : Loosening of the ground upto level of 500 mm below
the sub grade level, watered, graded & Compacted in layers to meet
requirment of table 300-2 for sub grade construction complete as per
specifications. case-1: Compacting original ground supporting sub grade Cum 48.10
(which includes watering charges and compaction by vibratory
roller)MORTH Specification No. 305.3.4 (PWD SR2011-
12/P.No.157/19.65)

19.66 KSRRB -300-59.2 : Loosening levelling and compacting original ground


suuporting embankment to facilitate placement of first layer of
embankment, scarified to a depth of 150 mm ,mixed with water at OMC
and then compacted by rolling so as to achieve minimum dry density as
given in Table 300-2 for embankment construction. complete as per
specifications. case-II: Compacting original ground supporting Cum 24.50
embankment (which includes watering charges and compaction by
vibratory roller)MORTH Specification No. 305.3.4 (PWD SR2011-
12/P.No.157/19.66)

19.67 KSRRB -300-60 : Extra for laying earth by manual meance as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done simultaneously with excavation of earth work and
dressing but excluding rolling and watering including cost of all labour. Cum 7.15
complete as per specifications. MORTH Specification No. 305.3.4 (PWD
SR2011-12/P.No.157/19.67)

19.68 KSRRB -300-61 : Extra for laying earth by manual meance as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done from stacked materials including breaking of clods
and dressing but excluding rolling and watering including cost of all labour. Cum 30.80
complete as per specifications. MORTH Specification No. 305.3.4 (PWD
SR2011-12/P.No.157/19.68)
19.69 KSRRB -300-62 : Extra for laying earth by mechanical meance as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done from stacked materials including breaking of clods
and dressing but excluding rolling and watering including cost of all labour. Cum 21.00
HOM of machineries complete as per specifications. MORTH Specification
No. 305.3.4 (PWD SR2011-12/P.No.157/19.68)

19.70 KSRRB -300-63 : Construction of Embankment with Flyash / Pond Ash


available from Coal or Lignite Burning Thermal Plants as Waste Material.
Construction of embankment with flyash conforming to Table 1 of IRS :
SP:58-2001 obtained from coal or lignite burning thermal power stations as
waste material, spread and compacted in layer of 200mm thickness each Cum 75.50
at OMC, all as speicified in IRC:SP-58-2001 and as approved plans
complete as per specifications. (PWD SR2011-12/P.No.157/19.70)

19.71 KSRRB -300-64.1 : Extra for watering thr earth to bring the earth upto
required optimum moisture content manually including cost of all labour
complete as per specifications. MORTH Specification No. 305.3.4 (PWD Cum 5.30
SR2011-12/P.No.158/19.71)

19.72 KSRRB -300-64.2 : Extra for watering thr earth to bring the earth upto
required optimum moisture content with mechinery including cost of all
labour, HOM of machineries complete as per specifications. MORTH Cum 1.75
(PWD SR2011-12/P.No.158/19.72)

19.73. KSRRB -300-65 : Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired filed density
not less than 95% of maximum dry density ( modified heavy proctor test ) Cum 15.50
including HOM of machineries complete as per specifications. MORTH
(PWD SR2011-12/P.No.158/19.73)

19.74 KSRRB -300-66 : Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired filed density
not less than 100% of maximum dry density ( modified heavy proctor test ) Cum 19.40
including HOM of machineries complete as per specifications. MORTH
(PWD SR2011-12/P.No.158/19.74)

19.75 KSRRB -300-67 : Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired filed density
not less than 100% of maximum dry density ( modified heavy proctor test )
Cum 6.95
including HOM of machineries complete as per specifications. MORTH
(PWD SR2011-12/P.No.158/19.75)

19.76 KSRRB -300-68 : Extra for rolling to specification with power roller 8-10
tonne when earth is at suitable moisture content with desired field density
not less than 100% of maximum dry density ( ordinary proctor test ) Cum 8.70
including HOM of machineries complete as per specifications. MORTH
(PWD SR2011-12/P.No.158/19.76)
KSRRB M300-HORTICULTURE
KSRRB M300-Spreading of sludge farm yard manure or/ and good
earth.
19.77 KSRRB -300-1 : Spreading of sludge farm yard manure or /and good earth
in required thickness (Cost of sludge, farm yard manure or / and good
earth to be paid for separately ) Complete as per specifications No. 307. Cum 46.10
MORTH (PWD SR2011-12/P.No.158/19.77)

KSRRB M300-Grassing with Doobs grass


19.78 KSRRB -300-2.1 : Grassing with Doobs grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn free from weeds and fit for moving including supplying good earth if
needed complete as per specifications. MORTH Specification No.307. Sqm 40.60
i) In rows 15 cm apart in either direction. (PWD SR2011-
12/P.No.158/19.78)

19.79 KSRRB -300-2.2 : Grassing with Doobs grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn free from weeds and fit for moving including supplying good earth if
needed complete as per specifications. MORTH Specification No.307. Sqm 78.00
i) In rows 7.5 cm apart in either direction. (PWD SR2011-
12/P.No.158/19.79)

KSRRB M300-Making lawns including ploughing and dradding with


'swagha' breaking of clod
19.80 KSRRB -300-3 : Making lawns including ploughing and breaking of clod,
removal of rubbish, dressing and supplying doobs grass and planting at 15
cm apart, including supplying and spreading of farm yard manure at Sqm 12.70
MORTH Specification No.307. . (PWD SR2011-12/P.No.159/19.80)

KSRRB M300-Maintenance of lawns or Turfing


19.81 KSRRB -300-4 : Maintenance of lawns or Turfing of slopes (rough
grassing) for a period of one year including watering etc complete as per
specifications. MORTH Specification No. 307 (PWD SR2011- Sqm 76.35
12/P.No.159/19.81)

KSRRB M300-Turfing lawns with fine grassing including ploughing,


dressing
19.82 KSRRB -300-5 : Turfing lawns with fine grassing including ploughing,
dressing including breaking of clods, removal of rubbish, dressing and
supplying doobs grass roots at 10 cm apart, including supplying and
spreading of farm yard manure at rate of 0.6 cum per 100 sqm complete Sqm 15.65
as per specifications. MORTH Specification No. 307(PWD SR2011-
12/P.No.159/19.82)

KSRRB M300- Maintenance of lawns with fine grassing for the first
year
19.83 KSRRB -300-6 :Maintenance of lawns with fine grassing for the first year
including watering etc complete as per specifications. MORTH Sqm 65.60
Specification No. 307. (PWD SR2011-12/P.No.159/19.83)

KSRRB M300-Planting and Maintenance permanent hedges


19.84 KSRRB -300-7.1 : Planting permanent hedges including diggid of
trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed
with farmyard manure, supplied at the rate of 4.65 cum per 100 metres
and supplying and planting hedge plants at 30 cm apart complete as per m 67.20
specification. A) Planting permanent hedges including digging of trenches.
MORT & H Specification No. 307 (PWD SR2011-12/P.No.159/19.84)

19.85 KSRRB -300-7.1 : Planting permanent hedges including diggid of


trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed
with farmyard manure, supplied at the rate of 4.65 cum per 100 metres
and supplying and planting hedge plants at 30 cm apart complete as per m 97.50
specification. A) Maintenance of hedge for one year. MORT & H
Specification No. 307 (PWD SR2011-12/P.No.159/19.84)

KSRRB M300-Planting and Maintaining of Flowering Plants and


Shrubs
19.86 KSRRB -300-8.1: Planting and Maintaining of Flowering Plants and
Shrubs- A) Planting flowering plants and shrubs in central verge . MORTH m 16.15
Specification No. 307 (PWD SR2011-12/P.No.159/19-86)

19.87 KSRRB -300-8.2: Planting and Maintaining of Flowering Plants and


Shrubs- A) Maintenance of flowering plants and shrubs in central verge fo
rone year.. MORTH Specification No. 307 (PWD SR2011- Km 106056.00
12/P.No.159/19.87)

KSRRB M300- Planting of trees and their maintenance for one year

19.88 KSRRB -300-9 : Planting of trees by the road side (Avenue trees )in 0.60
m dia holes, 1 m deep dug in the ground, mixing the soil with decayed
farm yard/sludge manure, planting the saplings, backfilling the trench,
watering, fixing, the tree guard and maintaining the plants for one year Each 523.00
complete as per specifications. MORT & H Specification No. 307(PWD
SR2011-12/P.No.160/19.88)

KSRRB M300- Renovation lawns including, weeding, forking the


ground, top dressing with forked soil.
19.89 KSRRB -300-10 :Renovation lawns including, weeding, forking the ground,
top dressing with forked soil, watering and maintenance the lawns for 30
days or more, till the grass forms a thick lawn, free from weeds, and fit for
moving and disposal of rubbish as directed, including supplying good Sqm 8.70
earth, if needed but excluding the cost of well decayed farmyard nature.
complete as per specifications. MORTH Specification No. 308 (PWD
SR2011-12/P.No.160/19.89)

KSRRB M300-Supply at site of work well decayed farm yard manure.


19.90 KSRRB -300-11 : Supply at site of work well decayed farm yard manure
from any available source, approved by the engineers incharge including
screening and stackin complete as per specifications. MORT & H Cum 132.00
Specification No. 308.2(PWD SR2011-12/P.No.160/19.90)

KSRRB M300-Supply at site of work / store-deoiled neem cake.


19.91 KSRRB -300-11 : Supply at site of work / store-deoiled neem cake duly
pakced in used gunny bags complete as per specifications. MORT & H q 1080.00
Specification No. 308.2(PWD SR2011-12/P.No.160/19.91)

KSRRB M300-Supply sludge.


19.92 KSRRB -300-12 : Supplying sludge duly stacked at site / store complte as
per specifications. MORT & H Specification No. 308.2(PWD SR2011- Cum 132.00
12/P.No.160/19.92)

KSRRB M300-Half brick circular tree guard.


19.93 KSRRB -300-13 : Half brick circular tree guard in 2nd cloths brick, internal
diametre 1.25 metres and hight 1.2 metres, above ground and 0.20 metre
below ground, bottom two courses lide dry, and top three courses in
cement morter 1:6 (1 cement 6 sand ) and intermediate courses being in Each 1251.00
dry honey comb masonry, as per design complete, complete as per
specifications. MORT & H Specification No. 308.2(PWD SR2011-
12/P.No.160/19.92)

KSRRB M300-Edging with 2nd class bricks, laid dry lengthwise


19.94 KSRRB -300-15 : Edging with 2nd class bricks, laid dry lengthwise
including excavation, refilling, consolidation, with a hand packing and
spreading nearly surplus within a lead of 50 metres, complete as per m 25.05
specifications. (PWD SR2011-12/P.No.160/19.94)

KSRRB M300-Making tree guard from empty bitumen drums


19.95 KSRRB -300-16: Making tree guard 53 cm dia and 1.3 m high as per
design from empty bitumin drum, slite suitably to permit sun and air,
( Supplyed by the Department at stock issue rate) including
Providing and fixing 2 Nos MS sheet rings 50x0.5 mm with rivers, Each 291.40
copmplete in all respect complete as per specifications. (PWD SR2011-
12/P.No.161/19.95)

19.96 KSRRB -300-17: Making tree guard 53 cm dia and 2 m high as per design
from empty bitumin drum, slite suitably to permit sun and air,
( Supplyed by the Department at stock issue rate) including Providing and
fixing four legs 40 cm long of 30x3 mm MS riveted to tree guard and Each 574.00
providing and fixing 2 Nos MS sheet rings 50x0.5 mm with rivers,
copmplete in all respect complete as per specifications. (PWD SR2011-
12/P.No.161/19.96)

KSRRB M300-Wrought Iron and mild steel welded work.


19.97 KSRRB -300-18: Wrought Iron and mild steel welded work. (Using angles,
square bars, tees and channel grills, grating frames, gates and tree guards
of any side and design etc.,includign cost of screens and welding rods or
bolts and nuts complete fixed in position but without the cost of excavation q 6389.00
and concrete for fixing which will be paid saperately complete as per
specifications. (PWD SR2011-12/P.No.161/19.97)

KSRRB M300-Tree gaurd with MS iron.


19.98 KSRRB -300-19: Providing and fixing MS iron free guard 60 cm dia and 2
metre high above ground level formed of 4 Nos (25 x 6 mm) and 8 Nos (25
mm X 3 mm ) vertical MS riveted to 3 Nos (25 X 6 mm ) iron rings in two
halves, bolted together with 8 mm dia and 30 mm long bolts including Each 1743.00
painting two coats woth paint of approved brand over a coat of priming,
complete in all respects, complete as per specifications. (PWD SR2011-
12/P.No.161/19.98)

KSRRB M300-Tree gaurd with MS Angle and Steel wire.


19.100 KSRRB -300-20: Providing and fixing tree guard 0.60 metre square, 2.00
metre high fabricated with MS angle iron 30 X 30 X 30 mm, MS iron 25 x 3
mm and steel wire 3 mm dia welded and fabricated as per design in two Each 2050.00
halves bolted together complete as per specifications. (PWD SR2011-
12/P.No.161/19.100)

KSRRB M300-Compensatory afforestation.


19.101 KSRRB -300-21: Planting trees as compensatory afforestaiton at the rate
of 290 trees per hectare at a spacing of 6 m by grubbing and leveling the
ground upto a depth of 150 mm, digging holes 0.9 m dia, 1 m deep, mixing Ha 52092.00
farm yard / sludge manure with soil, planting of saple. complete as per
specifications. (PWD SR2011-12/P.No.161/19.101)
SUB BASES - BASES (NON BITUMINOUS)
AND SHOULDERS
Sl. Description Rate
Unit
No. Rs. Ps.
KSRRB 400 - Granular Sub-base
20.1 KSRRB 400-1. Providing, laying, spreading and compacting inverted
choke of screening Type 'B' or sand in sub-base course in uniform layer on
a prepared base by mechanical means with motor grader and compacting
with power roller including cost of all materials, labour, HOM of Cum 1420.00
machineries complete as per specifications -MORTH chapter 4 (PWD
SR2011-12/P.No.163/20.1)

20.2 KSRRB 400-2. Providing, laying, spreading and compacting specified


graded sand, gravel or any other course material in sub-base course
including premixing the material at OMC in mechanical mixer (Pug mill),
carriage of mixed material up to 1 km, spreading in uniform layers with
motor grader on a prepared base and compacting with power roller to Cum 1743.00
achieve the desired density including all materials, labour, HOM of
machinery, lighting, guarding, barricading and maintenance of diversion
complete as per specifications -MORTH chapter 4 (PWD SR2011-
12/P.No.163/20.2)

20.3 KSRRB 400-4. Providing, laying, spreading and compacting specified


graded sand, gravel or any other course material in sub-base course
including premixing the material at OMC in mechanical mixer (Pug mill),
carriage of mixed material up to 1 km, spreading in uniform layers with
motor grader on a prepared base and compacting with power roller to
achieve the desired density lighting, guarding, barricading and Cum 1747.00
maintenance of diversion, including cost of all materials, labour, HOM of
machinery, complete as per specifications (material and grinding shall be
as per design mix formula) -MORTH chapter 4 (PWD SR2011-
12/P.No.163/20.3)

20.4 KSRRB M400-6.1. Construction of granular sub-base by providing close


graded Material, mixing in a mechanical mix plant at OMC, carriage of
mixed Material to work site, spreading in uniform layers with motor grader
on prepared surface and compacting with vibratory power roller to achieve
the desired density, complete as per specifications. A. Plant Mix Method
using grit (PWD SR2011-12/P.No.163/20.4)

20.4.1 KSRRB M400-6.1. Construction of granular sub-base by providing close


graded Material, mixing in a mechanical mix plant at OMC, carriage of
mixed Material to work site, spreading in uniform layers with motor grader
on prepared surface and compacting with vibratory power roller to achieve Cum 911.00
the desired density, For Grading I Material complete as per specifications.
(PWD SR2011-12o.163/20.4.1)
20.4.2 Construction of granular sub-base by providing close graded Material,
mixing in a mechanical mix plant at OMC, carriage of mixed Material to
work site, spreading in uniform layers with motor grader on prepared
surface and compacting with vibratory power roller to achieve the desired Cum 881.00
density, complete as per clause 401 of MORT & H For Grading - II Material
(225*1.28 = 288 cum) (PWD SR2011-12/P.No.163/20.4.2)

20.4.3 Construction of granular sub-base by providing close graded Material,


mixing in a mechanical mix plant at OMC, carriage of mixed Material to
work site, spreading in uniform layers with motor grader on prepared
surface and compacting with vibratory power roller to achieve the desired Cum 819.00
density, complete as per clause 401 of MORT & H For Grading - III
Material (PWD SR2011-12/P.No.163/20.4.3)

20.5 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density,
complete as per specifications. B. By Mix in Place Method using grit
(PWD SR2011-12/P.No.163/20.5)

20.5.1 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density, Cum 982.00
complete as per specifications. Close graded granular sub-base material
as per 400-1 For grading I Material (PW SR2011-12/P.No.164/20.5.1)

20.5.2 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density, Cum 733.00
complete as per specifications. Close graded granular sub-base material
as per 400-1 For grading II Material (PW SR2011-12/P.No.164/20.5.2)

20.5.3 KSRRB M400-6.2. Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method by rotavator at OMC,
and compacting with vibratory power roller to achieve the desired density, Cum 723.00
complete as per specifications. Close graded granular sub-base material
as per 400-1 For grading III Material (PW SR2011-12/P.No.164/20.5.3)

KSRRB 400 Granular Sub-Base with Coarse Graded Material


(table 400-2)
20.6 KSRRB M400-7 Construction of granular sub-base by providing coarse
graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method with rotavator at OMC,
and compacting with vibratory roller to achieve the desired density,
complete as per specifications using grit. (PWD SR2011-
12/P.No.164/20.6)

20.6.1 KSRRB M400-7 Construction of granular sub-base by providing coarse


graded material, spreading in uniform layers with motor grader on
prepared surface, mixing by mix in place method with rotavator at OMC,
and compacting with vibratory roller to achieve the desired density, Cum 973.00
complete as per specifications using grit. For Coarse graded granular sub-
base material as per 400-2 For grading I Material (PWD SR2011-
12/P.No.164/20.6.1)

20.6.2 Construction of granular sub-base by providing coarse graded material,


spreading in uniform layers with motor grader on prepared surface, mixing
by mix in place method with rotavator at OMC, and compacting with
vibratory roller to achieve the desired density, complete as per clause 400- Cum 885.00
2 of MORT & H For Grading - IIMaterial (PWD SR2011-
12/P.No.164/20.6.2)

20.6.3 Construction of granular sub-base by providing coarse graded material,


spreading in uniform layers with motor grader on prepared surface, mixing
by mix in place method with rotavator at OMC, and compacting with
vibratory roller to achieve the desired density, complete as per clause 400- Cum 765.00
2 of MORT & H For Grading - III Material (PWD SR2011-
12/P.No.164/20.6.3)

KSRRB M400-Lime stabilization for improving subgrade


20.7 KSRRB M400-8.1 Laying, and spreading available soil in the subgrade on
a prepared surface, pulverising, mixing the spread soil in place with
rotavator with 3 percent slaked lime having minimum content of 70 percent
of CaO, grading with motor graded and compacting with the road roller at
OMC to the desired density to form a layer of improved subgrade complete Cum 284.00
as per specifications. A. By Mechanical means. MORT & H. Specificaton
No.402. (PWD SR2011-12/P.No.164/20.7)

20.8 KSRRB M400-8.2 Lime Stabilisation for improving Subgrade Laying, and
spreading available soil in the subgrade on a prepared surface,
pulverising, mixing the spread soil in place with rotavator with 3 percent
slaked lime having minimum content of 70 percent of CaO, grading with
motor graded and compacting with the road roller at OMC to the desired Cum 288.00
density to form a layer of improved subgrade complete as per
specifications. B. By Manual means. MORT & H. Specificaton No.402.
(PWD SR2011-12/P.No.164/20.8)

KSRRB M400 - Lime Treated Soil for Sub-Base.


20.9 KSRRB M400-9 Providing, Laying, and spreading soil on a prepared
subgrade, pulverising, mixing the spread soil in place with rotavator with 3
percent slaked lime having minimum content of 70 percent of CaO,
grading with motor graded and compacting with the road roller at OMC to Cum 352.00
achieve atleast 90% of the maximum dry density to form a layer of sub-
base complete as per specifications. MORT & H. Specificaton No.402.
(PWD SR2011-12/P.No.164/20.9)

KSRRB M400 - Cement Treated Soil for Sub-Base/Base.


20.10 KSRRB M400-10 Providing, Laying, and spreading soil on a prepared
subgrade, pulverising, adding the designed quantity of cement to the
spread soil mixing in place with the rotavator grading with motor graded
and compacting with the road roller at OMC to achieve the desired
unconfined compressive strength and to form a layer of sub-base/base Cum 837.00
complete as per specifications.( For 4% quantity of cement by weight of
soil).,MORT & H. Specificaton No.403. (PWD SR2011-12/P.No.165/20.10)

KSRRB M400 - Cement Treated Crushed rock or Combination as per


Clause 403.2 & Table 400.4 in Sub-Base/Base.
20.11 KSRRB M400-11 Providing, Laying, and spreading material soil on a
prepared subgrade, adding the designed quantity of cement to the spread
material, mixing in place with the rotavator grading with motor graded and
compacting with the road roller at OMC to achieve the desired unconfined
compressive strength and to form a layer of sub-base/base complete as
per specifications.( quantity of cement assumed as 4% of quantity of
crushed rock by weight ).,MORT & H. Specificaton No.403. (PWD
SR2011-12/P.No.165/20.11)

20.11.1 KSRRB M400-11 Providing, Laying, and spreading material soil on a


prepared subgrade, adding the designed quantity of cement to the spread
material, mixing in place with the rotavator grading with motor graded and
compacting with the road roller at OMC to achieve the desired unconfined
compressive strength and to form a layer of sub-base/base complete as Cum 1590.00
per specifications.Cement at site at 4% by wt. of crushed aggregate
(600 tonne) Grading of material for Sub-base course.,MORT & H.
Specificaton No.403. (PWD SR2011-12/P.No.165/20.11.1)

20.11.2 KSRRB M400-11 Providing, Laying, and spreading material soil on a


prepared subgrade, adding the designed quantity of cement to the spread
material, mixing in place with the rotavator grading with motor graded and
compacting with the road roller at OMC to achieve the desired unconfined
compressive strength and to form a layer of sub-base/base complete as Cum 1400.00
per specifications.Cement at site at 4% by wt. of crushed aggregate
(600 tonne) Grading of material for base course.,MORT & H.
Specificaton No.403. (PWD SR2011-12/P.No.165/20.11.2)

KSRRB M400 - Making 50mm X 50mm Furrows


20.12 KSRRB M400 - Making 50mm X 50mm Furrows, 25mm deep, 450 to the
center line of the road and at one meter interval in the existing thin
bituminous wearing coarse including sweeping and disposal of excavated
material within 1000 metres lead Complete as per specifications. MORTH Sqm 2.40
specification No. 404.3.1 (PWD SR2011-12/P.No.165/20.12)

KSRRB M400-Inverted Choke


20.13 KSRRB M400-13. Construction of Inverted Choke by providing, laying,
spreading and compacting screening B type/coarse sand of specified
grade in uniform layer on a prepared surface with motor grade and Cum 1425.00
compacting with power roller etc., Complete as per specifications. .
MORTH specification No. 404.3.2 (PWD SR2011-12/P.No.165/20.13)

KSRRB M400 - Water Bound Macadam


20.14 KSRRB M400-14.1. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and
compacting to the required density. complete as per specification.
A. By manual means. MORTH Specification No. 404. (PWD
SR2011-12/P.No.165/20.14)

20.14.1 KSRRB M400-14.1. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1212.00
compacting to the required density. complete as per specification.
Type A 13.2mm for grading II. MORTH Specification
No. 404. (PWD SR2011-12/P.No.166/20.14.1)

20.14.2 KSRRB M400-14.2. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1098.00
compacting to the required density. complete as per specification.
Crushable type such as Moorum or Gravel for
grading III. MORTH Specification No. 404. (PWD SR2011-
12/P.No.166/20.14.2)
20.14.3 KSRRB M400-9. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1371.00
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Scrining Type-B (11.2mm agg.) Grading-III (Manual) Clause : 404 of
MORT & H. (PWD SR2011-12/P.No.166/20.14.3)

20.14.4 Providing, laying, spreading and compacting stone aggregates of specific


sizes to water bound macadam specification including spreading in
uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory
roller 8-10 tonnes in stages to proper grade and camber, applying and
brooming requisite type of screening/binding Materials to fill up the
interestices of coarse aggregate, watering and compacting to the required Cum 1190.00
density. Material (Refer table 400 - 7, 8 & 9) Using Screening Crushable
type such as Moorum or Gravel for Grading - III (Manual) Clause : 404 of
MORT & H. (PWD SR2011-12/P.No.166/20.14.4)

20.15 KSRRB M400 - 14.2. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and
compacting to the required density. Complete as per specifications.
B.Mechanical means. MORT & H Specification No. 404. (PWD SR2011-
12/P.No.166/20.15)

20.15.1 Providing, laying, spreading and compacting stone aggregates of specific


sizes to water bound macadam specification including spreading in
uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory
roller 8-10 tonnes in stages to proper grade and camber, applying and
brooming requisite type of screening/binding Materials to fill up the Cum 1106.00
interestices of coarse aggregate, watering and compacting to the required
density. Material (Refer table 400 - 7, 8 & 9) Using Scrining Type-A
(13.2mm agg.) Grading - II (Mechanical) Clause : 404 of MORT & H.
(PWD SR2011-12/P.No.166/20.15)

20.15.2 KSRRB M400-14.2. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 993.00
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Screening Crushable type such as Moorum or Gravel Grading - III
(Mechanical) Clause : 404 of MORT & H. (PWD SR2011-
12/P.No.166/20.15.2)
20.15.3 KSRRB M-400.14.2. Providing, laying, spreading and compacting stone
aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding Cum 1265.00
Materials to fill up the interestices of coarse aggregate, watering and
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Scrining Type-B (11.2mm agg.) Grading - III (Mechanical) Clause :
404 of MORT & H. (PWD SR2011-12/P.No.166/20.15.3)

20.15.4 KSRRB M400-14.2. Providing, laying, spreading and compacting stone


aggregates of specific sizes to water bound macadam specification
including spreading in uniform thickness, hand packing, rolling with 3
wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
Materials to fill up the interestices of coarse aggregate, watering and Cum 1084.00
compacting to the required density. Material (Refer table 400 - 7, 8 & 9)
Using Screening Crushable type such as Moorum or Gravel Grading - III
(Mechanical) Clause : 404 of MORT & H. (PWD SR2011-
12/P.No.166/20.15.2)

KSRRB M400-Crushed cement Sub-base/base.


20.16 KSRRB -400-15. Breaking and crushing of material obtained by breaking
damaged cement concrete slabs to size range not exceeding 75mm as
specified in Table 400.7 transporting the aggregate obtained from breaking
of cement concrete slabs, laying and compacting the same as sub-
base/base course, constructed as WBM to Clause 400.4 except the use of Cum 159.40
screening or binding material complete as per specifications. MORTH
Specification No. 405. (PWD SR2011-12/P.No.166/20.16)

KSRRB M400 - Penetration Coat over top layer of crushed cement


concrete base.

20.17 KSRRB -400-16 Spreading of bitumen over cleaned dry surface of crushed
cement concrete base at the rate of 25 kg per 10 sqm by a bitumen
pressure distributor, spreading of key aggregates at the rate of 0.13 cum
per 10 sqm by a mechanical gritter and rolling the surface as per clause Sqm 16.30
500.6.3.8 Complete as per specification. No.405.2 (PWD
SR2011-12/P.No. 166/20.17)

KSRRB M400 - Wet mix Macadam


20.18 KSRRB M400-17. Providing, laying, spreading and compacting graded
stones aggregates to wet mix macadam specification including pre mixing
the material with water at OMC in mechanica; mix plant carriage of mixed
method of tipper to site, laying in uniform layers with pavar in sub-
base/base course on well prepared surface and compacting with vibratory Cum 982.00
roller to achieve the desired density complete as per specifications.
MORTH Specification No. 406. (PWD SR2011-12/P.No.166/20.18)
KSRRB M400-Construction of Median and Island with soil taken from
Roadway cutting.
20.19 KSRRB M400-18. Construction of Median and Island above road level with
approved material deposited at site from roadway cutting and excavation
for drain foundation of other structures, spread, graded and compacted as Cum 91.65
per clause 400.7 complete as per specifications. MORTH Specification
No. 406. (PWD SR2011-12/P.No.167/20.19)

KSRRB M400-Construction of Median and Island with soil taken from


Borrow Areas.
20.20 KSRRB M400-19. Construction of Median and Island with island with Soil
taken from Borrow Areas. Construction of Median and island above road
level with approved material deposited from borrowpits, spread, sloped Cum 105.20
and compacted as per Clause 400.7 complete as per specifications.
MORTH Specification No. 407. (PWD SR2011-12/P.No.167/20.20)

KSRRB M400-Construction of footpath and separator


20.21 KSRRB M400-.21.Construction of footpath /separator by providing a 150
mm compacted granular sub-base as per clause 401 & 25mm thick
cement concrete grade M-15, overlaid with precast concrete tiles in
cement mortar 1:3 including provision of all drainage arrangements but Sqm 541.00
excluding kerb channel complete as per specification.MORTH
Specification No. 409. (PWD SR2011-12/P.No.167/20.21)

KSRRB M400-22 Crusher Rum Macadam base


20.22 KSRRB M400-.22.1. Providing crushed stone aggregate, depositing on a
prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 960.00
A. By mix in place method. (For 53 mm maximum
size) MORTH Specification No. 410. (PWD SR2011-12/P.No.167/20.22)

20.23 KSRRB M400-.22.1. Providing crushed stone aggregate, depositing on a


prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 955.00
A. By mix in place method. (For 45 mm maximum
size) MORTH Specification No. 410. (PWD SR2011-12/P.No.167/20.23)

20.24 KSRRB M400-.22.2. Providing crushed stone aggregate, depositing on a


prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 1060.00
A. By mixing Plant method. (For 53 mm maximum
size) MORTH Specification No. 410. (PWD SR2011-12/P.No.167/20.24)

20.25 KSRRB M400-.22.2. Providing crushed stone aggregate, depositing on a


prepared surface by houling vehicles, spreading and mixing with a motor
grader, watering and compacting with a vibratory roller to clause 410 to
form a layer of sub-base/base. complete as per specification. Cum 1067.00
A. By mixing Plant method. (For 45 mm maximum
size) MORTH Specification No. 410. (PWD SR2011-12/P.No.167/20.25)
KSRRB M400- Lime. Flyash stabilised Soil Sub-base.
20.26 KSRRB M400-23. Lime. Flyash stabilised Soil Sub-base. Construction of
sub-base using lime-flyash admixture with granular soil, free from organic
matter/deleterious material or clayey silts and low plasticity clays having PI
between 5 & 20 and liquid limit less than 25 and commercial dry lime
slaked at site or pre-slaked with CaO content not less than 50 %, flyash to
conform to gradation as per Clause 43 of IRC: 88-1984, lime+flyash Cum 206.00
content ranging between 10 to 30%, the minimum un-confined
compressive strength and CBR value after 28 days curing and 4 days
soaking to be 705 kg/sqcm and 25% respectively, all as specified in
IRC:88-1984 complete as per specifications. (PWD SR2011-
12/P.No.168/20.26)

KSRRB 400- Base


20.27 KSRRB M400-24. Providing, laying, spreading and compacting stone
aggregate of specific sizes to water bound macadam specifications by
manual means, including spreading in uniform thickness, hand packing,
rolling with power roller 8-10 tonnes in stages to proper grade and camber,
applying and brooming requisite type of screening/binding materials to fill
up the interstices of coarse aggregates, watering and rolling, making
necessary earthern bund to protect edges, lighting, guarding, barricading, Cum 983.00
and maintenance of diversion, including cost of all materials, labour, HOM
of machinery, complete as per specifications. MORTH Chapter 4 (PWD
SR2011-12/P.No.168/20.27)

20.28 KSRRB 400-25. Providing, laying, spreading and compacting stone


aggregate of specific sizes to water bound macadam specifications by
mechanical means, including spreading in uniform thickness, hand
packing, rolling with power roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding
materials to fill up the interstices of coarse aggregates, watering and
rolling, making necessary earthern bund to protect edges, lighting, Cum 972.00
guarding, barricading, and maintenance of diversion, including cost of all
materials, labour, HOM of machinery, complete as per specifications.
MORTH Chapter 4 (PWD SR2011-12/P.No.168/20.28)
BASE AND SURFACE COURSES (BITUMINOUS)

Sl.No. Description
Unit Rate

KSRRB 500-1. Cleaning the existing surface.


21.1 KSRRB 500-1 : Cleaning the existing WBM road sufrace including
removing of binding materials and other foreign matter with wire brushes
and small picks, sweeping wih brooms or soft brushes and finally dusting
with old gunny bags and / or compressed air, to receive bituminous
treatment including cost of all materials, labour, HOM of machineries Sqm 9.30
complete as per specifications. MORT & H (PWD SR2011-12/P.No.
171/21.1)

21.2 KSRRB 500-.2 : Cleaning the existing black topped surface with brooms,
soft brushes and finally dusting with old gunny bags and / or compressed
air to receive bituminous treatment including cost all materials, labour,
HOM of machineries complete as per specifications. MORT & H (PWD Sqm 2.35
SR2011-12/P.No. 171/21.2)

21.3 KSRRB 500-3 : Scarifying existing stone metal layer upto 75mm thick
along with their bituminous surface, picking up scarified materials and
stacking of old serviceable materilas with lead of 100 m. sequential
spreading of the salvaged aggregates with fresh aggregates on prepared
base and consolidatig as per water bound macadam specifications Sqm 63.30
including cost all materials, labour, HOM of machineries complete as per
specifications. MORT & H (PWD SR2011-12/P.No. 171/21.3)

KSRRB 500-Applying primer coat over prepared surface


21.4 KSRRB 500-4. Providing and applying primer coat from 7.5 to 9.8 kg and
9.8 to 12.2 kg per 10 sqm for surfaces of low and medium porosity
respectively over prepared surface of granular base with cut back M.C-70
or any other bitumen mixed with diesel at 10kg per 10 sqm heated in
bitumen boiler fitted with spray set (excluding cleaning of road surface)
including cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH (PWD SR2011-12/P.No.171/21.4)

21.4.1 KSRRB 500-4. Providing and applying primer coat from 7.5 to 9.8 kg and
9.8 to 12.2 kg per 10 sqm for surfaces of low porosity respectively over
prepared surface of granular base with cut back M.C-70 or any other
bitumen mixed with diesel at 10kg per 10 sqm heated in bitumen boiler
fitted with spray set (excluding cleaning of road surface) including cost of Sqm 55.40
all materials, labour, HOM of machineries complete as per specifications.
MORTH (PWD SR2011-12/P.No.171/21.4.1)
21.4.2 KSRRB 500-4. Providing and applying primer coat from 7.5 to 9.8 kg and
9.8 to 12.2 kg per 10 sqm for surfaces of medium porosity respectively
over prepared surface of granular base with cut back M.C-70 or any other
bitumen mixed with diesel at 10kg per 10 sqm heated in bitumen boiler
fitted with spray set (excluding cleaning of road surface) including cost of Sqm 68.95
all materials, labour, HOM of machineries complete as per specifications.
MORTH (PWD SR2011-12/P.No.171/21.4.1)

21.5 KSRRB 500-5. Providing and applying primer coat from 12.2 to14.6kg per
10 sqm for surfaces of high porosity over prepared surface of granular
base with cut back M.C-70 or any other bitumen mixed with diesel at 13kg
per 10 sqm heated in bitumen boiler fitted with spray set (excluding
cleaning of road surface) including cost of all materials, labour, HOM of Sqm 97.00
machineries complete as per specifications. MORTH (PWD SR2011-
12/P.No.171/21.5)

KSRRB 500-Primer coat/Tack coat


21.6 KSRRB M500-6. Providing and applying primer coat with bitumen
emulsion on prepared surface of granular Base including clearing of road
surface and spraying primer at the rate of 0.60 kg/sqm using mechanical
Sqm 33.30
means. Complete as per specifications MORTH Specification No. 502
(PWD SR2011-12/P.No.171/21.6)

21.7 KSRRB M500-8. Providing and applying tack coat on the prepared black
topped surface at 7.5 kg per 10 sqm, heating bitumen in boiler fitted with
spray set (excluding cleaning of road surface) including cost of all
materials labour, HOM of machineriesComplete as per specifications Sqm 13.18
MORTH (PWD SR2011-12/P.No.172/21.7)

21.8 KSRRB M500-8. Providing and applying tack coat on granular surface
treated with primer at 7.5 kg per 10 sqm, heating bitumen in boiler fitted
with spray set (excluding cleaning of road surface) including cost of all
materials labour, HOM of machineriesComplete as per specifications Sqm 16.03
MORTH (PWD SR2011-12/P.No.172/21.8)

21.9 KSRRB M500-9. Providing and applying tack coat on granular base such
as WBM and WMM surfaces hot bitumen prined at 10 kg per 10 sqm,
heating bitumen in boiler fitted with spray set (excluding cleaning of road
surface) including cost of all materials labour, HOM of
Sqm 21.37
machineriesComplete as per specifications MORTH (PWD SR2011-
12/P.No.172/21.9)

21.10 KSRRB M500-10 : Tack coat:- Providing and applying Tack coat with
bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg
per sqm on the prepared bituminous/granular surface cleaned with
mechanical broom. complete As per Specification MORTH specification
No. 503. (PWD SR2011-12/P.No.172/21.10)
21.10.1 -do- using bitumen emulsion Sqm 9.20

21.10.2 -do- using bitumen 80/100 Sqm 10.30

KSRRB 500-Bituminous macadam


21.11 KSRRB M500-11: Providing and laying bituminous macadam on prepared
surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E.loader, hot
mixing of stone aggregates and bitumen in hot mix plant 40-60 tonne
capacity, transporting the mixed material in tipper tp paver and laying
mixed materials with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density,
50/75 mm compacted thickness with 3.3% bitumen but excluding cost of
primer/tack coat with lead upto 1 km including cost of all materials, labour,
HOM of machineries complete as per specifications.
MORTH Specification No. 504.
(Bitumen=0.072 ton/cum metal=1.415) (PWD SR2011-12 /P.No.172/
21.11)

21.11.1 KSRRB M500-11: Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E.loader, hot
mixing of stone aggregates and bitumen in hot mix plant 40-60 tonne
capacity, transporting the mixed material in tipper tp paver and laying
mixed materials with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density,
80/100 mm compacted thickness with 3.3% bitumen but excluding cost of Cum 5107.00
primer/tack coat with lead upto 1 km including cost of all materials, labour,
HOM of machineries complete as per specifications.
MORTH Specification No. 504.
(Bitumen=0.072 ton/cum metal=1.415) (PWD SR2011-12 /P.No.172/
21.11)

21.11.2 KSRRB M500-11: Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E.loader, hot
mixing of stone aggregates and bitumen in hot mix plant 40-60 tonne
capacity, transporting the mixed material in tipper tp paver and laying
mixed materials with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density,
60/70 mm compacted thickness with 3.3% bitumen but excluding cost of Cum 5194.00
primer/tack coat with lead upto 1 km including cost of all materials, labour,
HOM of machineries complete as per specifications.
MORTH Specification No. 504.
(Bitumen=0.072 ton/cum metal=1.415) (PWD SR2011-12 /P.No.172/
21.11.2)
21.12 KSRRB 500-12. Providing, laying and consolidating of crushed stone
aggregates on prepared surface as per built up spray grout specifications
75mm thick, as base course complete in two layers composite constructon
of crushed stone aggregates with application of bitumen binder after each
layer and lay aggregate on the top of second layer and rolling with power
roller 8 to 10 tonne but excluding cost of primer / tack coat including cost Sqm 284.00
of all materials, labour, HOM of machineries complete as per
specifications. MORTH Chapter 5 with 80/100 grade bitumen
(Bitumen=0.003 ton metal=0.113) (PWD SR2011-12 /P.No.172/ 21.12)

21.13 KSRRB 500-13. Providing, laying bituminous macadam 50mm thick with
100-120 TPH hot mix plant producing an average output of 75 tonnes per
hour using crushed aggregates of specified grading premixed with
bituminous binder, transported to site, laid over a previously prepared
surface with paver finisher hydrostatic with sensor control to the required
grade, level and alignment and rolled as per Clauses 501.6 and 501.7 to
achieve the desired compaction complete as per sepcifications using
80/100 grade bitumen MORTH Specification No. 504 (PWD SR2011-
12/P.No.173/ 21.13)

21.13.1 -do- 80-100 mm compacted thickness (grading |) with 3.1% bitumen Cum 5010.00

21.13.2 -do- 50-75 mm compacted thickness (grading ||) with 3.3% bitumen Cum 5187.00

KSRRB M500- Bituminous Penetration macadam


21.14 KSRRB M500-14.1. Construction of penetration macadam over prepared
base by Providing and layer of compacted crushed coarse aggregate
using chips spreader with alternate applications of bituminious binder and
key aggregates and rolling with a vibratory roller 8-10 tonne capacity to Sqm 304.00
achieve the desired degree of compaction. complete as per specifications.
A. 50mm thick. MORTH Specification No. 505 (PWD SR2011-
12/P.No.173/20.14)

21.15 KSRRB M500-14.1. Construction of penetration macadam over prepared


base by Providing and layer of compacted crushed coarse aggregate
using chips spreader with alternate applications of bituminious binder and
key aggregates and rolling with a vibratory roller 8-10 tonne capacity to Sqm 398.00
achieve the desired degree of compaction. complete as per specifications.
A. 75mm thick. MORTH Specification No. 505 (PWD SR2011-
12/P.No.173/20.15)

KSRRB 500-Built up Spray Grout


21.16 KSRRB M500-15. Providing, laying and rolling with vibratory roller of built-
up spray grout layer over prepared base consisting of a two layer
composite construction of compacted crushed coarse aggregates using
motor grader for aggregates. Key stone chips spreader may be used with
application of bituminious binder after each layer, and with key aggregates
placed on top of the second layer to serve as a base conforming to the
line, grades and cross-section specified, the compacted layer thickness Sqm 201.00
being 75 mm complete as per specifications. MORTH Specification No.
506 with 80/100 grade bitumen (Bitumen=0.003 metal=0.113) (PWD
SR2011-12/P.No.173/21.16)

KSRRB 500-Dense bituminous macadam


21.17 KSRRB M500-16. Providing, laying dense bituminous macadam 40mm
compcated thickness with 5% bitumen 80/100 grade, contents on prepared
surface with specified graded crushed aggregates for base/binder course
including loading of material with F.E. loader, heating of binder aggregates
and filler in hot mix plant 40-60 TPH, transporting the mixed material by
tipper and laying with paver finisher mechanical 100 TPH to the required
level and grade, rolling by power roller to achieve the desired density (but Cum 7028.00
excluding primer / tack coat ) to a lead upto 1km including cost of all
materials, labour, HOM of machineries complete as per specifications.
( Bitumen=0.115 Metal=1.528) MORTH (PWD SR2011-
12/P.No.173/20.17)

21.18 KSRRB M500-17. Providing and laying dense graded bituminous


macadam with 100-125 TPH batch type HMP producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.0 to 4.5 percent by weight
of total mix and filler, transporting the hot mix to work site, laying with a
hydrostatic paver finisher with sensor control to the required grade, level
and alignment, rolling with smooth wheeled, vibratory and tandem rollers
to achieve the desired compaction as per MORTH specification clause No.
507 complete in all respects as per specifications, bitumen 80/100
(Bitumen = 0.0981 Metal = 1.44) MORTH Specification No. 507. (PWD
SR2011-12/P.No.173/20.18)

21.18.1 -do- 80-100mm compacted thickness (Grading |) with 4% Bitumen Cum 6177.00

21.18.2 -do- 50-75mm compacted thickness (Grading ||) 4.5% Bitumen Cum 6738.00

21.19 KSRRB M500-17. Providing and laying dense graded bituminous


macadam with 100-125 TPH batch type HMP producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.0 to 4.5 percent by weight
of total mix and filler, transporting the hot mix to work site, laying with a
hydrostatic paver finisher with sensor control to the required grade, level
and alignment, rolling with smooth wheeled, vibratory and tandem rollers
to achieve the desired compaction as per MORTH specification clause No.
507 complete in all respects as per specifications, bitumen 60/70
(Bitumen = 0.0981 Metal = 1.44) MORTH Specification No. 507. (PWD
SR2011-12/P.No.174/20.19)
21.19.1 -do- 80-100mm compacted thickness (Grading |) with 4% Bitumen Cum 6286.00

21.19.2 -do 50-75mm compacted thickness (Grading ||) with 4.5% Bitumen Cum 7353.00

KSRRB M500-Semi dense bituminous concrete


21.20 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.50 to 5.00 percent of mix
and filler, transporting the hot mix to work site, laying with a hydrostatic
paver finisher with sensor controll to the required grade,level and
alignment, rolling and smooth wheeled, vibratory and tandem rollers to
acheive the desired compaction as per MORTH Specification clause
No.500.8 complete in all respects. as per specifications (Bitumen = 0.104
Metal = 1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20)

21.20.1 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7284.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.1) (80/100
grade bitumen )

21.20.2 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7420.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.3) (60/70
grade bitumen )
21.20.3 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7482.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.3) (80/100
grade bitumen using 40-60 HMP)

21.20.4 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7618.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.4) (60/70
grade bitumen using 40-60 HMP)

21.20.5 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
Cum 7435.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.5) (80/100
grade bitumen using 40-60 HMP & Mechanical Paver)

21.20.6 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
25mm thick with 40-60 TPH batch type HMP producing an avarage output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 4.50 to 5.00 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7571.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.6) (60/70
grade bitumen using 40-60 HMP & Mechanical Paver)
21.20.7 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
35-40mm thick with 40-60 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.5% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 5530.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.7) (80/100
grade bitumen using 40-60 HMP & Mechanical Paver) (Grading |)

21.20.8 KSRRB M-500-18: Providing and laying semi dense bituminous concrete
35-40mm thick with 40-60 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.5% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 6440.00
desired compaction as per MORTH Specification clause No.500.8
complete in all respects. as per specifications (Bitumen = 0.104 Metal =
1.43, Cement = 0.0442) (PWD SR2011-12/P.No.174/21.20.8) (60/70
grade bitumen using 40-60 HMP & Mechanical Paver) (Grading |)

21.21 KSRRB M500-18. Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.50 to 5.00 percent of mix
and filler, transporting the hot mix to work site, laying with a hydrostatic
paver finisher with sensor controll to the required grade,level and
alignment, rolling and smooth wheeled, vibratory and tandem rollers to
acheive the desired compaction as per MORTH Specification clause No.
508 complete in all respects as per specifications (PWD SR2011-
12/P.No.174/21.21)

21.21.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.5% to 5% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment, Cum 6873.00
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 508
complete in all respects as per specifications (PWD SR2011-
12/P.No.174/21.21) with CRMB/POLYMER MB 70
21.21.2 KSRRB M500-18. Providing and laying semi dense bituminous concrete
25mm thick with 100-120 TPH batch type HMP producing an avarage
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 4.5% to 5% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor controll to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 6873.00
desired compaction as per MORTH Specification clause No. 508
complete in all respects as per specifications (PWD SR2011-
12/P.No.175/21.21) with NRMB 70 (LATEX OR RUBBER POWDER)

KSRRB M500-Bituminious Concrete


21.22 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4% to5.6% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2011-
12/P.No.175/21.22)

21.22.1 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 6% of mix and filler, transporting the
hot mix to work site, laying with a hydrostatic paver finisher with sensor
control to the required grade,level and alignment, rolling and smooth
wheeled, vibratory and tandem rollers to acheive the desired compaction Cum 8437.00
as per MORTH Specification clause No. 500.9 complete in all respects as
per specifications. MORTH Specification No. 509 (Bitumen=0.117,
Metal=1.462, Cement=0.045) (PWD SR2011-12/P.No.175/21.22.1) with
Bitumen 80/100

21.22.2 KSRRB M500-19. Providing and laying bituminous concrete 35-40mm


thick with 100-120 TPH batch type hot mix plant producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 5.4 to 5.6 percent of mix and
filler, transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 8604.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2011-
12/P.No.175/21.22.2) with Bitumen 60/70
21.22.3 KSRRB M500-19. Providing and laying bituminous concrete 35-40mm
thick with 100-120 TPH batch type hot mix plant producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 6 % of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
Cum 8640.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2011-
12/P.No.175/20.22.3) with 80/100 grade Bitumen using 40-60 HMP

21.22.4 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 6% of mix and filler, transporting the
hot mix to work site, laying with a hydrostatic paver finisher with sensor
control to the required grade,level and alignment, rolling and smooth
wheeled, vibratory and tandem rollers to acheive the desired compaction Cum 8807.00
as per MORTH Specification clause No. 500.9 complete in all respects as
per specifications. MORTH Specification No. 509 (Bitumen=0.117,
Metal=1.462, Cement=0.045) (PWD SR2009-10/P.No.175/21.22.4) with
60/70 grade Bitumen using 40-60 HMP

21.22.5 KSRRB M500-19. Providing and laying bituminous concrete 30-45mm


thick with 100-120 TPH batch type hot mix plant producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 6% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 8592.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.175/21.22.5) with 80/100 grade Bitumen using 40-60 HMP

21.22.6 KSRRB M500-19. Providing and laying bituminous concrete 30-45mm


thick with 100-120 TPH batch type hot mix plant producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 6% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 8759.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.175/21.22.6) with 60/70 grade Bitumen using 40-60 HMP
21.22.7 KSRRB M500-19. Providing and laying bituminous concrete 50-65mm
thick with 100-120 TPH batch type hot mix plant producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 5.5% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7979.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.175/21.22.6) with 80/100 grade Bitumen using 40-60 HMP

21.22.8 KSRRB M500-19. Providing and laying bituminous concrete 50-65mm


thick with 100-120 TPH batch type hot mix plant producing an average
output of 75 tonnes per hour using crushed aggregates of specified
grading, premixed with bituminous binder @ 5.5% of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 8133.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. MORTH Specification No.
509 (Bitumen=0.117, Metal=1.462, Cement=0.045) (PWD SR2009-
10/P.No.175/21.22.6) with 60/70 grade Bitumen using 40-60 HMP

21.23 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. (PWD SR2011-
12/P.No.175/21.23)

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment, Cum 7495.00
rolling and smooth wheeled, vibratory and tandem rollers to acheive the
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. (PWD SR2011-
12/P.No.175/21.23.1) With CRMB / POLYMER MB 70
21.23.2 KSRRB M500-19. Providing and laying bituminous concrete 40mm thick
with 100-120 TPH batch type hot mix plant producing an average output
of 75 tonnes per hour using crushed aggregates of specified grading,
premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler,
transporting the hot mix to work site, laying with a hydrostatic paver
finisher with sensor control to the required grade,level and alignment,
rolling and smooth wheeled, vibratory and tandem rollers to acheive the Cum 7495.00
desired compaction as per MORTH Specification clause No. 500.9
complete in all respects as per specifications. (PWD SR2011-
12/P.No.175/21.23.2) With NRMB 70 (LATEX OR RUBBER POWDER)

KSRRB 500-Extra for protecting the crushed stone chipping


21.24 KSRRB 500-21.1. Extra for labour for protecting the crushed stone
chipping with bitumen including heating and mixing the materials by
manual means and handling the mixed materials within a lead of 30 m.
Cum 590.00
including cost of all labour, HOM of machineries complete as per
specifications. MORTH Chapter 5 (PWD SR2011-12/P.No.175/21.24)

21.25 KSRRB 500-21.2. Extra for labour for protecting the crushed stone
chipping with bitumen including heating and mixing the materials by
mechanical means and handling the mixed materials within a lead of 30
m. including cost of all labour, HOM of machineries complete as per Cum 758.00
specifications. MORTH Chapter 5 (PWD SR2011-12/P.No.175/21.25)

KSRRB 500-Surface dressing


21.26 KSRRB 500-22. Providing and laying single coat surface dressing or first
coat of the two surface dressing with 0.15 cum crushed stone chippings
and bitumen 18 kg / 10 sqm as wearing course consisting of a layer of
bituminious binder laid on the prepared surface followed by cover of
crushed stone chippings of specified size (may be pre-coated also) and Sqm 106.00
materials, labour, HOM of machineries complete as per specifications,
MORTH Chapter 5 (PWD SR2011-12/P.No.176/21.26)

21.27 KSRRB 500-23. Providing and laying second coat surface dressing (also
used as renewal one coat ) with 0.10 cum crushed layer as wearing
courseand bitumen 11 kg / 10 sqm as wearing course consisting of a layer
of bituminious binder laid on the prepared surface and rolling with power Sqm 69.35
roller 8-10 tonne capacity including cost of all materials, labour, HOM of
machineries complete as per specifications, MORTH Chapter 5 (PWD
SR2011-12/P.No.176/21.27)
21.28 KSRRB M500-24.1. Providing and laying surface dressing as wearing
course in single coat using crushed stone aggregates of specified size on
a layer of bituminious binder laid on prepared surface and rolling with 8-10
tonne smooth wheeled steel roller complete as per specifications. Case-I :- Sqm 73.80
19mm nominal chipping size MORTH Specifiacation No. 510 (PWD
SR2011-12/P.No.175/21.28)

21.29 KSRRB M500-24.2. Providing and laying surface dressing as wearing


course in single coat using crushed stone aggregates of specified size on
a layer of bituminious binder laid on prepared surface and rolling with 8-10
tonne smooth wheeled steel roller complete as per specifications. Case- Sqm 58.50
II :- 13mm nominal size chipping (Bitumen= 1kg/Sqm Metal=0.01)
MORTH Specifiacation No. 510 (PWD SR2011-12/P.No.175/21.29)

KSRRB 500-Open Graded premix carpet


21.30 KSRRB M500-25. Providing and laying open graded premix carpet using
bitumen and with specified graded crushed aggregates of 13.2mm to
5.6mm size for wearing course including loading of aggregates with F.E,
loader , heating binder and aggregates in hotmix plant 30 to 40 tonne,
transporting the mixed materials in tipper to a distance upto 1 km and
laying with paver finisher mechanical with capacity to required level and Sqm 103.50
grade, rolling with power roller 8-10 tonne excluding cost of tack and seal
coat including cost of all materials, labour, HOM of machineries complete
as per specifications. MORTH Chapter 5 (PWD SR2011-
12/P.No.176/21.30)

21.31 KSRRB M500-25. Providing and laying open graded premix carpet using
crumb rubber modified bitumen (CRMB 55) and with specified graded
crushed aggregates of 13.2mm to 5.6mm size for wearing course including
loading of aggregates with F.E, loader , heating binder and aggregates in
hotmix plant 30 to 40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km and laying with paver finisher mechanical with capacity Sqm 105.10
to required level and grade, rolling with power roller 8-10 tonne excluding
cost of tack and seal coat including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTH Chapter 5 (PWD
SR2011-12/P.No.176/21.30)

21.32 KSRRB M500-27. Providing and laying open graded premix carpet of
20mm thick on prepared surface as wearing course composed of 13.2 mm
to 5.6 mm size stone aggregates premixed with bituminous binder in mini
hot mix plant 6-10 tonne exclduing cost of primer / tack coat including cost
Sqm 112.15
of all materials, labour, HOM of machineries complete as per
specifications.80/100 Bitumen (Bitumen=1.46 kg/Sqmt Metal= 0.027)
MORTH Chapter 5 (PWD SR2011-12/P.No.177/21.32)
21.33 KSRRB M500-28. Providing and laying open graded premix carpet of
20mm thick on prepared surface as wearing course composed of 13.2 mm
to 5.6 mm size stone aggregates premixed with bituminous binder in mini
hot mix plant 6-10 tonne exclduing cost of primer / tack coat including cost
of all materials, labour, HOM of machineries complete as per Sqm 113.80
specifications.80/100 Bitumen (Bitumen=1.46 kg/Sqmt Metal= 0.027)
MORTH Chapter 5 (PWD SR2009-10/P.No.152/21.33) Using CRMB

21.34 KSRRB M500-29.1. Providing laying and rolling of open graded premix
surfacing of 20mm thickness composed of 13.2 mm to 5.6 mm aggregates
either using penetration grade bitumen or cut-back or emulshion to
required line, grade and level to serve as wearing course on a previously
prepared base, including mixing in a HMP 100 TPH plant, laying and
rolling with a smooth wheeled roller 8-10 tonne capacity, finished to Sqm 100.00
required level and grades complete as per specifications.Case-1:
Mechanical method using penetration grade bitumen and HMP of
appropriate capacity not less than 75 tonne/hour" MORTH Specification
No.511 (PWD SR2011-12/P.No.177/21.34)

21.35 KSRRB M500-29.2. Providing laying and rolling of open graded premix
surfacing of 20mm thickness composed of 13.2 mm to 5.6 mm aggregates
either using penetration grade bitumen or cut-back or emulshion to
required line, grade and level to serve as wearing course on a previously
prepared base, including mixing in a HMP 100 TPH plant, laying and
rolling with a smooth wheeled roller 8-10 tonne capacity, finished to Sqm 136.20
required level and grades complete as per specifications.Case-II: Open
graded Pre mix Surfacing using cationic bitumen emulshion. MORTH
Specification No.511 (PWD SR2011-12/P.No.177/21.35)

KSRRB 500-30 Mix seal surface


21.36 KSRRB M500-30. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface as wearing course with specified graded crushed
aggregates of 11.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 20-30 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher 30-40 tonne capacity to
required level and grade, rolling with power roller 8-10 tonne excluding Sqm 137.55
cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications. using 80/100 grade
bitumen.MORTH Chapter 5 (PWD SR2011-12/P.No177/21.36)

21.36.1 KSRRB M500-30. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface as wearing course with specified graded crushed
aggregates of 11.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 20-30 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher 30-40 tonne capacity to
required level and grade, rolling with power roller 8-10 tonne excluding Sqm 140.00
cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications. using 60/70 grade
bitumen.MORTH Chapter 5 (PWD SR2011-12/P.No177/21.36.1)
21.37 KSRRB M500-31. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface as wearing course with specified graded crushed
aggregates of 11.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 20-30 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher 30-40 tonne capacity to
required level and grade, rolling with power roller 8-10 tonne excluding
Sqm 140.00
cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications.MORTH Chapter 5 (PWD
SR2011-12/P.No.177/21.37) with crumb rubber modified bitumen (CRMB
55) Morth Chapter 5

21.38 KSRRB M500-32. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface as wearing course with specified graded crushed
aggregates of 13.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 30-40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher to required level and
grade, rolling with power roller 8-10 tonne excluding cost of tack coat Sqm 122.60
including cost of all materials, labour, HOM of machineries complete as
per specifications. using 80/100 grade bitumen.MORTH Chapter 5 (PWD
SR2011-12/P.No.177/21.38)

21.38.1 KSRRB M500-32. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface as wearing course with specified graded crushed
aggregates of 13.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 30-40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher to required level and
grade, rolling with power roller 8-10 tonne excluding cost of tack coat Sqm 124.90
including cost of all materials, labour, HOM of machineries complete as
per specifications. using 60/70 grade bitumen MORTH Chapter 5 (PWD
SR2011-12/P.No.178/21.38.1)

21.39 KSRRB M500-33. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface as wearing course with specified graded crushed
aggregates of 13.2 mm to 0.09 mm size premixed with bituminous binder,
in hotmix plant 30-40 tonne, transporting the mixed materials in tipper to a
distance upto 1 km. and laying with paver finisher to required level and
grade, rolling with power roller 8-10 tonne excluding cost of tack coat
including cost of all materials, labour, HOM of machineries complete as Sqm 124.70
per specifications.MORTH Chapter 5 (PWD SR2011-12/P.No.178/21.39)
with crumb rubber modified bitumen binder Morth Chapter 5

21.40 KSRRB M500-34. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface in a single course composed of specified graded
crushed aggregates of 11.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8-
Sqm 144.50
10 excluding cost of primer/ tack coat including cost of all materials,
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2011-12/P.No.178/21.40)
21.41 KSRRB M500-35. Providing and laying 20mm thick mix seal surfacing Typr
'A' on prepared surface in a single course composed of specified graded
crushed aggregates of 11.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8-
10 excluding cost of primer/ tack coat including cost of all materials, Sqm 147.00
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2011-12/P.No.178/21.41) with crumb rubber modified
bitumen (CRMB55) MORTH Chapter 5

21.42 KSRRB M500-36. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface in a single course composed of specified graded
crushed aggregates of 13.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8- Sqm 136.00
10 excluding cost of primer/ tack coat including cost of all materials,
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2011-12/P.No.178/21.42)

21.43 KSRRB M500-37. Providing and laying 20mm thick mix seal surfacing Typr
'B' on prepared surface in a single course composed of specified graded
crushed aggregates of 13.2 mm to 0.09 mm size premixed with bitumen in
a minimix plant 6/10 tonne, laying manually and rolling with power roller 8-
10 excluding cost of primer/ tack coat including cost of all materials, Sqm 131.90
labour, HOM of machineries complete as per specifications.MORTH
Chapter 5 (PWD SR2011-12/P.No.178/21.43) with crumb rubber modified
bitumen (CRMB 55)

KSRRB M500-Close-graded premix surfacing / Mixed Seal surfacing

21.44 KSRRB M500-38.1. Providing, laying and rolling of Close-graded premix


surfacing material of 20 mm thickness composed of 13.2 mm to 0.09 mm
(Type-B) aggregates using penetration grade bitumen 80/100 to the
required line, grade and level to serve as wearing course on a previously
prepared base, including mixing in a 40-60 TPH HMP plant, laying with
Sqm 117.40
Paver finisher mechanical 100 T cappacity and rolling with a Smooth
wheeled roller as per specifications. (Bitumen+1.90 Kg/Sqm Metal=0.027)
MORTH Specification No. 512. (PWD SR2011-12/P.No.178/21.44)

KSRRB M500-Seal coat


21.45 KSRRB M500-39.1. Providing and laying a seal coat sealing the voids in
bituminious surface lay to the specified levels, grade 80/100 and cross fall
using Type'A' and B seal coats, Complete as per specifications using low
grade bitumen. (PWD SR2011-12/P.No.178/21.45)

21.45.1 KSRRB M500-39.1. Providing and laying a seal coat sealing the voids in
bituminious surface lay to the specified levels, grade 80/100 and cross fall
using Type'A' and B seal coats, Complete as per specifications using low Sqm 53.40
grade bitumen. Case: I. Type A (Bitumen 0.98 kg/Sqm Metal=0.009)
MORTH Specifications No. 513 (PWD SR2011-12/P.No.178/21.45.1)
21.45.2 KSRRB M500-39.1. Providing and laying a seal coat sealing the voids in
bituminious surface lay to the specified levels, grade 80/100 and cross fall
using Type'A' and B seal coats, Complete as per specifications using low Sqm 39.75
grade bitumen. Case: I. Type B (Bitumen 0.68 kg/Sqm Metal=0.009)
(PWD SR2011-12/P.No.178/21.45.2)

21.46 KSRRB M500-39.2. Providing and laying of premix sand seal coat with
HMP of appropriate capacity not less than 75 tonnes/hours using crushed
stone chipping 6.7 mm size and pentration bitumen of suitable grade Sqm 39.90
complete as per specifications. Case: II Type B
MORTH Specification No. 513. (PWD SR2011-12/P.No.179/21.45.2)

KSRRB M500-Mastic asphalt


21.47 KSRRB M500-41. Providing and laying 25 mm thick mastic asphalt
wearing course with paving grade bitumen the requirements given in table
500-29, prepared by using mastic cooker and laid to required level and
slope after cleaning the surface, including providing antiskid surface with
bitumen precoated fine grained hard stone chipping of 13.2 mm nominal
size at the rate of 0.005 cum per 10 sqm and at an approximate spacing of
10 cm center to center in both directions, pressed insto surface when the Sqm 435.00
temperature of surfaces is not less than 100'C, producing 1 mm to 4 mm
over mastic surface, complete as per clause 500.15 as per specifications.
(PWD SR2011-12/P.No.179/21.47) Morth Specification No. 515

KSRRB M500-Recycling of bituminous pavement with Central


recycling plant
21.52 KSRRB M500-47. Recycling pavement by cold milling of exisitng
bituminious layers. Planning the surface after cold milling, reclaiming
excavated material to the extent of 30 percent of the required quantity,
hauling and stock pilling the reclaimed material near the central recycling
plant after carrying out necessary checks and evaluation, adding fresh
material including rejuvenators as required, mixing in a hot mix plant, Cum 5180.00
transporting and laying at site and compacting to the required grade, level
and thickness, as specfied in clause 500.17 complete as per
specifications. MORTH Specification No. 517. (PWD SR2011-
12/P.No.179/21.52)

KSRRB M500-Frog Spray


21.53 KSRRB M500-48. Providing and applying low viscosity bitumen emulsion
for sealing cracks less than 3 mm wide or incipient fretting or
disintegration in an existing bituminous surfacing complete as per Sqm 31.00
specifications. MORTH Specifiction No. 518 (PWD SR2011-
12/P.No.179/21.53)
21.54 KSRRB M500-48. Providing and applying low viscosity bitumen emulsion
for sealing cracks less than 3 mm wide or incipient fretting or
disintegration in an existing bituminous surfacing complete as per Sqm 4.55
specifications. (PWD SR2011-12/P.No.179/21.54)

KSRRB M500-Bituminous Cold mix (Including Gravel emulshion


21.55 KSRRB M500-49.1. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 8679.00
grades and levels complete as per specifications. Case-I: Using bitumen
emulshion & 9.5 mm or 13.2 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2011-12/P.No.179/21.55)

21.56 KSRRB M500-49.2. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 8650.00
grades and levels complete as per specifications. Case-II: Using bitumen
emulshion &19 mm or 26.5 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2011-12/P.No.180/21.56)

21.57 KSRRB M500-49.3. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified
grades and levels complete as per specifications. Case-III: Using cutback Cum 9048.00
bitumen &9.5 mm or 13.2 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2011-12/P.No.180/21.57)

21.58 KSRRB M500-49.4. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified Cum 9009.00
grades and levels complete as per specifications. Case-IV: Using cutback
bitumen & 19 mm or 26.5 mm nominal size aggregate" MORTH
Specifiction No. 519 (PWD SR2011-12/P.No.180/21.58)

KSRRB M500-Sand-asphalt base course


21.59 KSRRB M500-50. Providing, laying and rolling sand-asphalt base course
composed of sand, mineral filler and bituminous binder on a preparedsub-
grade or sub-base to the lines, levels, grades and cross sections as per
the drawings including mixing in a plant of suitable type and capacity, Cum 7343.00
transporting, laying, compacting and finishing complete as per
specifications. MORTH Specifiction No. 520 (PWD SR2011-
12/P.No.180/21.59)

KSRRB 500-Liquid seal coat


21.60 KSRRB 500-52, Providing and applying Liquid seal coat Type 'A',
comprising of a layer of bituminous binder using bitumen followed by a
cover of stone chipping of 6.7 mm size and rolling with power roller 8-10
tonne including cost of all materials, labour, HOM of machineries complete Sqm 60.45
as per specifications using 80/100 Bitumen 0.98 kg/sqm Metal = 0.009)
MORTH Chapter 5.(PWD SR2011-12/P.No.180/21.60)

21.61 KSRRB 500-53, Providing and applying Liquid seal coat Type 'A',
comprising of a layer of bituminous binder using bitumen followed by a
cover of stone chipping of 6.7 mm size and rolling with power roller 8-10
tonne including cost of all materials, labour, HOM of machineries complete
Sqm 61.50
as per specifications using 80/100 Bitumen 0.98 kg/sqm Metal = 0.009)
MORTH Chapter 5.(PWD SR2011-12/P.No.181/21.61)Using crumb rubber
modified bitumen (CRMB 55)

21.62 KSRRB 500-54. Providing and applying premix seal coat Type 'B'
comprising of thin application of fine aggregates passing 2.36 mm and
retained on 180 micron premixed with layer of bitumen binder using mini
hot mix plant carrying manually mixed materials, laying, rolling with power
roller 8-10 tonne including cost of all materials, labour, HOM of Sqm 41.15
machineries complete as per specifications. using 80/100 Bitumen
(Bitumen 0.68 Kg/sqm sand/Fine aggregate=0.06 cum) (PWD SR2011-
12/.No.180/21.62)MORTH Chapter 5.

21.63 KSRRB 500-55. Providing and applying premix seal coat Type 'B'
comprising of thin application of fine aggregates passing 2.36 mm and
retained on 180 micron premixed with layer of bitumen binder using mini
hot mix plant carrying manually mixed materials, laying, rolling with power
roller 8-10 tonne including cost of all materials, labour, HOM of
Sqm 41.90
machineries complete as per specifications. using 80/100 Bitumen
(Bitumen 0.68 Kg/sqm sand/Fine aggregate=0.06 cum) MORTH Chapter
5. Using crumb rubber modified bitumen (CRMB 55)(PWD SR2011-
12/P.No.180/21.63)

KSRRB M500-Slurry seal


21.64 KSRRB M500-56.1. Providing and laying Slurry seal consisting of a
mixture of fine aggregates, portland cement filler, bituminous emulshion
and water on a road surface including cleaning of surface, mixing of slurry
seal in a suitable mobile plant, laying and compacting to provide even
riding surface Complete as per specifications. Case-I: 5 mm thickness Sqm 61.25
MORTH Specification No.516 (PWD SR2011-12/P.No.181/21.64)

21.65 KSRRB M500-56.2. Providing and laying Slurry seal consisting of a


mixture of fine aggregates, portland cement filler, bituminous emulshion
and water on a road surface including cleaning of surface, mixing of slurry
seal in a suitable mobile plant, laying and compacting to provide even
riding surface Complete as per specifications. Case-I: 3 mm thickness Sqm 42.40
MORTH Specification No.516 (PWD SR2011-12/P.No.181/21.65)
21.66 KSRRB M500-56.3. Providing and laying Slurry seal consisting of a
mixture of fine aggregates, portland cement filler, bituminous emulshion
and water on a road surface including cleaning of surface, mixing of slurry
seal in a suitable mobile plant, laying and compacting to provide even
Sqm 25.95
riding surface Complete as per specifications. Case-III: 1.5 mm thickness
MORTH Specification No.516 (PWD SR2011-12/P.No.181/21.66)

KSRRB M500-Crack Prevention Courses


21.67 KSRRB M500-57.1. Providing and laying of a stress absorbing membrane
over a Cracked road surface, with crack width below 6 mm after cleaning
with a mechanical broom, using modified binder complying with clause
500.21, sprayed at the rate of 9 kg per 10 sqm and spreading 5.6 mm
crushed stone aggregates at 0.11 cum per 10 sqm with hydraulic chip
spreader, sweeping the surface for uniform spread of aggregates and Sqm 51.10
surface finished to conform 900.2 complete as per specifiction. Case-I:
Stress absorbing membrane (SAM) crack width less than 6mm.
MORTH Specification No. 522 (PWD SR2011-12/P.No.181/21.67)

21.68 KSRRB M500-57.2. Providing and laying of a stress absorbing membrane


over a cracked road surface, with crack width 6 to 9 mm after cleaning with
a mechanical broom, using modified binder complying with clause 500.21,
sprayed at the rate of 11 kg per 10 sqm and spreading 11.2 mm crushed
stone aggregates at 0.12 cum per 10 sqm, sweeping the surface for
uniform spread of aggregates and surface finished to conform to clause Sqm 62.25
900.2 complete as per specification. Case-II: Stress absorbing
membrane (SAM) crack width 6 mm to 9 mm" MORTH Specification No.
522. (PWD SR2011-12/P.No181/21.68)

21.69 KSRRB M500-57.3. Providing and laying a single coat of a stress


absorbing membrane over a cracked road surface, with crack width above
9 mm and cracked area above 50% after cleaning with a mechanical
broom, using modified binder complying with clause 500.21, sprayed at the
rate of 15 kg per 10 sqm and spreading 11.2 mm crushed stone
aggregates at 0.12 cum per 10 sqm, sweeping the surface for uniform
Sqm 82.60
spread of aggregates and surface finished to conform to clause 900.2
complete as per specification. Case-III: Stress absorbing membrane (SAM)
crack width above 9 mm and cracked aread above 50%. MORTH
Specification No. 522. (PWD SR2011-12/P.No181/21.69)

21.70 KSRRB M500-57.4. Providing and laying a bitumen impregnated geotextile


layer after cleaning the road surface, geotextile conforming to
requirements of clause 700.3.3, laid over a tack coat with 1.05 kg per sqm
of paving grade bitumen 80-100 penetration and constructed to the
requirement of clause 700.3.4.5 complete as per specification. Case-IV: Sqm 129.65
Bitumen impregnated geotextile. MORTH Specification No. 522 (PWD
SR2011-12/P.No182/21.70)
KSRRB M500-Recipe Cold Mixes
21.71 KSRRB M500-58.1. Providing and laying of premix of crushed stone
aggregates and emulsion binder, mixed in a batch type cold mixing plant,
laid over prepared surface, by paver finisher, rolled with a peneumatic
tyred roller initially and finished with a smooth steel wheel roller, all as per
clause 500.19.3 complete as per specifications. Case-I : 75 mm Cum 5443.00
thickness. MORTH Specification No. 519.3 (PWD SR2011-
12/P.No182/21.71)

21.72 KSRRB M500-58.2. Providing and laying of premix of crushed stone


aggregates and emulsion binder, mixed in a batch type cold mixing plant,
laid over prepared surface, by paver finisher, rolled with a peneumatic
tyred roller initially and finished with a smooth steel wheel roller, all as per
clause 500.19.3 complete as per specifications. Case-II : 40 mm Cum 7771.00
thickness. MORTH Specification No. 519.3 (PWD SR2009-
10/P.No158/21.72)

21.73 KSRRB M500-58.2. Providing and laying of premix of crushed stone


aggregates and emulsion binder, mixed in a batch type cold mixing plant,
laid over prepared surface, by paver finisher, rolled with a peneumatic
tyred roller initially and finished with a smooth steel wheel roller, all as per Cum 8782.00
clause 500.19.3 complete as per specifications. Case-II : 25 mm
thickness. MORTH Specification No. 519.3 (PWD SR2011-
12/P.No182/21.73)
CONCRETE PAVEMENT
KSRRB M600- Cement concrete Pavements
22.1 KSRRB M600-1. Construction of dry lean Cement concrete Sub-base over
a prepared sub-grade with course and fine aggregates conforming to IS:
383, the size of coarse aggregate not exceeding 25 mm, aggregate
cement ratio not to exceed 15:1, aggregate gradation after blending to be
as per Table 600-1, cement content no to be less than 150 kg/cum,
optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days, Cum 2553.00
mixed in a batching plant, transported to site, laid with a paver with
electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing
and curing complete as per specifications. MORTH Specification No.601.
(PWD SR2011-12/P.No185/22.1).

22.2 KSRRB M600-2. Cement concrete Pavement :- Construction of un-


reinforced, dowel jointed, plain cement concrete pavement over a
prepared Sub-base with 43 grade cement at 400 kg per cum, coarse and
fine aggregates conforming to IS: 383, maximum size of coarse aggregate
not exceeding 25 mm, mixed in a batching and mixing plant as per
approved mix design, transported to site, laid with a fixed form or slip form
paver, spread, compacted and finished in a continuous operation including
provision of contraction, expansion, construction and longitudinal joints, Cum 4707.00
joint filler, separation membrane, sealant primer, joint sealant, debonding
strip, dowel bar, tie rod, admixtures as approved, curing compound,
finishing to lines and grades as per drawing complete as per
specifications. MORTH Specification No. 602. (PWD SR2011-
12/P.No185/22.2).

22.3 KSRRB M600-3. Construction of Rolled Cement concrete base course


with coarse and fine aggregates conforming to IS: 383, the size of coarse
aggregate not exceeding 25 mm, with minimum, aggregate cement ratio
15:1, and minimum cement content of 200 kg/cum, aggregate gradation to
be as per Table 600-4 after blending, mixing in batching plant at optimum
moisture content, transporting to site, laying with a paver with electronic Cum 2673.00
sensor, compacting with 8-10 tonnes smooth wheeled vibratory roller to
achieve, the designed flexural strength, finishing and curing complete as
per specifications. MORTH Specification No.603. (PWD SR2011-
12/P.No185/22.3).

KSRRB M600- Construction of Base / Sub-base of pavement with


Lean Concrete flyash
22.4 KSRRB M600-5. Construction of Base / Sub-base using cement, sand,
flyash and coarse aggregates proportioned as per table 4 of IRC: 74/1979
and with water cement ratio, slump and compressive strength as defined in
the said table, mix prepared in a batching and mixing plant and compacted
with a vibratory roller 8-10 tonnes capacity within the time limit laid down
vide clause 700.6.3 of IRC: 74-1979, construction joints properly formed at Cum 2245.00
the end of day's work, cured for 14 days, all as specified in IRC: 74-1979
and as per approved plans complete as per specifications. MORTH
Specification No. Suggestive.MORTH Specification No.603. (PWD
SR2011-12/P.No185/22.4).

KSRRB M600-Cement-Flyash concrete pavement


22.5 KSRRB M600-6. Construction reinforced, dowel jointed, plain cement
concrete pavement over a prepared sub base with 43 grade cement,
coarse and fine aggregates conforming to IS: 383, maximum size of
course aggregate not exceeding 25 mm, replacing cement by fly ash to the
extent of 15% and sand by 10%, mixed in a batching and mixing plant as
per approved mix design, transported to site, laid with a fixed form or slip
form paver, spread, compacted and finished in a continuous operation
including provision of contraction, expansion, construction and longitudinal Cum 4185.00
joints, joint filler, separation membrane, sealant primer, joint sealant,
debonding strip, dowel bar, tie rod, admixtures as approved, curing
compound, finishing to lines and grades as per drawing complete as per
specifications. MORTH Specification No. Suggestive.MORTH Specification
No.603. (PWD SR2011-12/P.No.186/22.5).

22.6 cement concrete pavement. Construction of un-reinforced plain cement


concrete pavement, thickness as per design, over a prepared sub base
with OPC cement or any other type as per clause 1051.2.2 design mix
M20/M30, with 25mm and down size graded granite metal coarse
aggregates and fine aggregates, with superplastisiser @3lts confirming to
IS 9103-1999 Reafirmed-2008, mixed in a conrete mixer of not less than
0.6 cum capacity and appropriate weigh batcher as per approved mix
design, laid in approved fixed side form work (steel channel, laying and
fixing of 125 micron thick polythene film, wedges, steel plates including
leveling the form work as per drawing). Spreading the concrete with
shovels, rackers compacted using needle, screed and plate vibrator and
finished in a continuos operation including provision of contraction,
expansion, construction and logitudinal joints, joint filler, saperation
membrane, selant primer, joint sealent, admixtures as approved, curing
compound, finishing to lines and grades as per drawing complete as per
specifications. (PWD SR2011-12/P.No.186/22.6).

22.6.1 M30 (at 360kg per cum coarse aggregate @ 0.69cum and fine aggregate
@ 0.46cum) (PWD SR2011-12/P.No.186/22.6.1). Cum 4204.00

22.6.2 M20 (at 300kg per cum coarse aggregate @ 0.64cum and fine aggregate
@ 0.43cum) (PWD SR2011-12/P.No.186/22.6.1). Cum 3707.00
22.7 Vaccum de-watering with vaccum pump and suction mat and compaction
with skin floater clubbed with floating disc including cost of generator,
HOM of machinery, Screed vibratory, power Floater, blade and disc etc., Sqm 80.00
all lead and lift. (PWD SR2011-12/P.No.186/22.7).

22.8 Providing groove cutting for width of 5mm to 10mm and depth 80mm to
100mm including cost of cutting machine, generator & HOM of machinery,
including cost of blade, coolent etc., including groove & providing sand and
hot bitumen fillars, and filler metal etc., including of conveyance of all
materials, labour, lead and lift charges and all other incidental charges as
per drawing and as per specifications. (PWD SR2011-12/P.No.187/22.8).

22.8.1 -do- for concrete pavement Rmt. 100.00

22.8.2 -do- for asphalt pvement Rmt. 60.00


GEOSYNTHETIC AND REINFORCED EARTH
23.1 KSRRB M700-1. Construction of sub surface drain 200 mm dia using
geotextilestreated with carbon black with physical properties as given in
clause 700.2.2.3 formed in to a stable network and a planar
geocomposites structure, joints wrapped with geotextiles to prevent m 468.00
ingress of soil, all as per clause 700.2 and approved drawings including
excavation and backfilling complete as per specifications. MORTH
Specification No. 702.(PWD SR2011-12/P.No.189/23.1).

23.2 KSRRB M700-2. Construction of a narrow filter sub surface drain Narrow
Filter Sub-surface Drain consisting of porous or perforated pipe laid in
narrow trench surrounded by a geotextiles filter fabric, with a minimum of
450 mm overlap of fabric and installed as per clause 700.2.2.3 and m 595.00
300.9.3.5 including excavation and backfilling complete as per
specifications. MORTH Specification No. 702.4(PWD SR2011-
12/P.No.189/23.2).

23.3 KSRRB M700-3. Laying Paving Fabric Beneath a Pavement Overlay:-


Providing and laying paving fabric with physical requirements as per Table
704-2 over a tack coat of paving grade Bitumen 80-100 penetration, laid at
the rate of 1 kg per sqm over thoroughly cleaned and repaired surface to
provide a water resistant membrane and crack retarding layer. Paving
fabric to be free of wrinkling and folding and to be laid before cooling of Sqm 73.80
tack coat, brooming and rolling of surface with pneumatic roller to
maximise paving fabric contact with pavement surface complete as per
specifications. MORTH Specification No. 703. (PWD SR2011-
12/P.No.189/23.3).

23.4 KSRRB M700-4. Laying Boulder Apron in crates of Synthetic Geogrids:-


Providing, preparing and laying of geogrids created apron 1 m x 5 m, 600
mm thick including excavation and backfilling with baffles at 1 metre
interval, made with geogrids having characteristics as per clause 700.4.2,
joining sides with connectors/ring staples, top corners to be tie tensioned,
placing of suitable cross interval tiles in layers of 300 mm connecting
opposite side with lateral braces and tied with polymer braids to avoid
bulging, constructed as per clause 700.4.3. filled with stone with minimum
Cum 3369.00
size of 200 mm and specific gravity not less than 2.65, packed with stone
spalls, keyed to the foundation recess in case of sloping ground and laid
over a layer of geotextiles to prevent migration of fines, all as per clause
700.4 and laid as per clause 200.5.3.3 and approved design complete a as
per specifications. MORTH Specification No. 704. (PWD SR2011-
12/P.No.189/23.4).
TRAFFIC SIGNS, MARKINGS & OTHER ROAD
APPURTENANCES
Sl. Description Rate
Unit
No. Rs. Ps.

24.1 KSRRB 800-1 : Painting two coats after filling the surface with synthetic
enamel paint in approved shades on new plastered concrete surfaces with
materials, labour complete as per specification, MORTH Chapter 8 (PWD Sqm 44.90
SR2011-12/P.No. 191/24.1)

24.2 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2)

24.2.1 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 2708.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) i) 90 cm equilaterial triangle

24.2.2 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 2021.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) ii) 60 cm equilaterial triangle

24.2.3 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 2351.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) iii) 60 cm Circular
24.2.4 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of
retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of No 2864.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) iv) 80 mm x 60 mm Rectangular

24.2.5 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 2318.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) v) 60 cm x 45 cm Rectangular

24.2.6 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
No 2552.00
properly designed foundation with M 15 grade cement concrete 45 cm x 45
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) vi) 60 cm x 60 cm Square

24.2.7 KSRRB 800-2 : Retro-Reflectorised Traffic Signs :- Providing and fixing of


retro-reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide clause 800.1.3, fixed
over Aluminium sheeting, 1.5 mm thick supported on a mild steel angle
iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of
properly designed foundation with M 15 grade cement concrete 45 cm x 45 No 3363.00
cm x 60 cm, 60 cm below ground level as per approved drawing complete
as per specifications. MORTH Specification No.801. (PWD SR2011-
12/P.No. 191/24.2.1) vi) 90 cm high octagon

24.3 KSRRB M800-3. Direction and Place Identification Signs upto 0.9 sqm
Size Board:- Providing and erecting direction and place identification
retro-reflectorised sign as per IRC:67 made of high intensity grade
sheeting vide clause 800.1.3, fixed over aluminium sheeting, 2 mm thick
with area not exceeding 0.9 sqm supported on a mild steel single angle
iron post 75 x75 x 6 mm firmly fixed to the ground by means of properly Sqm 4968.00
designed foundation with M-15 grade cement concrete 45 x 45 x 60 cm, 60
cm below ground level as per approved drawing complete as per
specifications. MORTH Specification No.801.(PWD SR2011-12/P.No.
191/24.3)
24.4 KSRRB M800-4. Direction and Place Identification Signs with size
more than 0.9 sqm Size Board:- Providing and erecting direction and
place identification retro-reflectorised sign as per IRC:67 made of high
intensity grade sheeting vide clause 800.1.3, fixed over aluminium
sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild
steel single angle iron post 75 x75 x 6 mm, 2 Nos. firmly fixed to the Sqm 5306.00
ground by means of properly designed foundation with M-15 grade cement
concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved
drawing complete as per specifications. MORTH Specification No.801.
(PWD SR2011-12/P.No. 191/24.4)

24.5 KSRRB M800-5.1. Over head Signs:- Providing and erecting overhead
signs with a corrosion resistant 2 mm thick aluminium alloy sheet
reflectorised with high intensity retro-reflective sheeting of encapsulated
lense type with vertical and lateral clearance given in clause 800.2.2 and
800.2.3 and installed as per clause 800.2.7, over a designed support
system pf aluminium alloy or galvanished steel trestles and trusses of Tonne 70637.00
sections and type as per structural design requirements and approved
plans complete as per specifications. A. Truss and Vertical Support
MORTH Specification No.802.(PWD SR2011-12/P.No. 192/24.5)

24.6 KSRRB M800-5.2. Providing and erecting overhead signs with a corrosion
resistant 2 mm thick aluminium alloy sheet reflectorised with high intensity
retro-reflective sheeting of encapsulated lense type with vertical and lateral
clearance given in clause 800.2.2 and 800.2.3 and installed as per clause
800.2.7, over a designed support system pf aluminium alloy or galvanished
steel trestles and trusses of sections and type as per structural design Sqm 5230.00
requirements and approved plans complete as per specifications. B.
Aluminium Alloy Plate for Over Head Sign MORTH Specification
No.802.(PWD SR2011-12/P.No. 192/24.6)

KSRRB M800-Painting Letters


24.7 KSRRB M800-6. Painting Two coats on New Concrete Surface:- Painting
two coats after filling the surface with synthetic enamel paint in all shades
on new plastered concrete surfaces complete as per specifications. Sqm 50.25
MORTH Specification No. 803.(PWD SR2011-12/P.No. 192/24.7)

24.8 KSRRB M800-7. Painting:- Painting and applying Two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803.
(PWD SR2011-12/P.No. 192/24.8)

24.8.1 KSRRB M800-7. Painting:- Painting and applying Two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803. Sqm 43.70
Painting on Steel Surface (PWD SR2011-12/P.No. 192/24.8.1)
24.8.2 KSRRB M800-7. Painting:- Painting and applying Two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803. Sqm 49.15
Painting on Wood Surface (PWD SR2011-12/P.No. 192/24.8.2)

24.9 KSRRB M800-9. Painting New Letter and figures of any Shade with
synthetic enamel paint black or any other approved colour to give an even
shade complete as per specifications. ("i) Hindi (Matras commas and the Cm 0.55
like not to be measured and paid for half letter shall be counted as half)
MORTH Specification No.801 (PWD SR2011-12/P.No. 192/24.9)

24.10 KSRRB M800-10. Painting New Letter and figures of any Shade with
synthetic enamel paint black or any other approved colour to give an even
shade complete as per specifications. ("ii) English and Roman-Hyphen and Cm 0.30
the like not to be measured and paid for MORTH Specification No.801
(PWD SR2011-12/P.No. 192/24.9)

24.11 KSRRB M800-11.1. Painting lines, dashes, arrows etc., on Roads in


two coats on New Work:- Painting lines, dashes, arrows etc., on Roads
in two coats on New Work with ready mixed road marking paint
conforming to IS:164 on Bituminous surface, including cleaning the surface
Sqm 93.20
of all dirt, dust and other foreign matter, demarcation at site and traffic
control complete as per specifications. i) Over 10 cm in width. MORTH
Specification No.803 (PWD SR2011-12/P.No. 193/24.11)

24.12 KSRRB M800-11.2. Painting lines, dashes, arrows etc., on Roads in


two coats on New Work:- Painting lines, dashes, arrows etc., on Roads
in two coats on New Work with ready mixed road marking paint
conforming to IS:164 on Bituminous surface, including cleaning the surface Sqm 83.80
of all dirt, dust and other foreign matter, demarcation at site and traffic
control complete as per specifications. ii) Upto10 cm in width. MORTH
Specification No.803 (PWD SR2011-12/P.No. 193/24.12)

24.13 KSRRB M800-12.1. Painting lines, dashes, arrows etc., on Roads in


two coats on Old Work:- Painting lines, dashes, arrows etc., on Roads in
two coats on old Work with ready mixed road marking paint conforming to
IS:164 on Bituminous surface, including cleaning the surface of all dirt, Sqm 74.70
dust and other foreign matter, demarcation at site and traffic control
complete as per specifications. i) Over 10 cm in width. MORTH
Specification No.803 (PWD SR2011-12/P.No. 193/24.13)

24.14 KSRRB M800-12.2. Painting lines, dashes, arrows etc., on Roads in


two coats on Old Work:- Painting lines, dashes, arrows etc., on Roads in
two coats on old Work with ready mixed road marking paint conforming to
IS:164 on Bituminous surface, including cleaning the surface of all dirt, Sqm 66.40
dust and other foreign matter, demarcation at site and traffic control
complete as per specifications. ii) Upto 10 cm in width. MORTH
Specification No.803 (PWD SR2011-12/P.No. 193/24.14)
24.15 KSRRB M800-13.Road Marking with Hot Applied Thermoplastic
Compound with Reflectrising Glass Beads on Bituminous Surface:-
Providing and laying of hot applied thermoplastic compound 2.5 mm thick
including reflectorising glass beads at 250 gms per sqm area, thickness of
2.5 mm is exclusive of surface applied glass beads as per IRC:35. The Sqm 398.00
finished surface to be level, uniform and free from streaks and holes
complete as per specifications. MORTH Specification No.803 (PWD
SR2011-12/P.No. 193/24.15)

KSRRB 800- Kilometre Stone


24.16 KSRRB 800-14.1. Reinforced cement concrete M-15 Grade kilometre
stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications. i) 5th kilometre Nos 2480.00
Stone (Precast) MORTH Specification No.804 (PWD SR2011-12/P.No.
193/24.16)

24.17 KSRRB 800-14.2. Reinforced cement concrete M-15 Grade kilometre


stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications. ii) Ordinary Nos 1552.00
kilometre Stone (Precast) MORTH Specification No.804 (PWD SR2011-
12/P.No. 193/24.17)

24.18 KSRRB 800-14.3. Reinforced cement concrete M-15 Grade kilometre


stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications. iii) Hectometre Nos 483.00
Stone (Precast) MORTH Specification No.804 (PWD SR2011-12/P.No.
194/24.18)

24.19 KSRRB 800-15. Road Delineators:- Supplying and installation of


delineators (road way indicators, hazard Markers, Object markers), 80-100
cm high above ground level, painted black and white in 15 cm wide strips,
fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised
panels at the top, buried or pressed into the ground and conforming to Nos 338.00
IRC-79 and the drawings complete as per specifications. iii) Hectometre
Stone (Precast) MORTH Specification No.805 (PWD SR2011-12/P.No.
194/24.19)

24.20 KSRRB 800-16. Boundary Pillar:- Reinforced cement concrete M-15


grade boundry pillars of standard design as per IRC:25-1967 fixed in
position including finishing and lattering but excluding painting complete as Nos 297.00
per specifications. MORTH Specification No.806 (PWD SR2011-12/P.No.
194/24.20)

KSRRB M800-Fencing / Railing


24.21 KSRRB M800-17. G.I. Barbed Wire Fencing 1.2 Metro High. Providing
and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron
posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center
founded in M15 grade cement concrete, 0.6 metre below ground level,
every 15th post, last but one end post and corner post shall be strutted on
both sides and end post on one side only and provided with 9 horizontal m 206.00
lines and 2 diagonals interwoven with horizontal wires, fixed with GI
staples, turn buckles etc complete as per clause 800.7 as per
specifications. MORTH Specification No. 807 (PWD SR2011-12/P.No.
194/24.21)

24.22 KSRRB M800-18. G.I. Barbed Wire Fencing 1.8 Metro High. Providing
and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron
posts 50 mm x 50 mm x 6 mm placed every 3 metres center to center
founded in M15 grade cement concrete, 0.6 metre below ground level,
every 15th post, last but one end post and corner post shall be strutted on
both sides and end post on one side only and provided with 12 horizontal m 356.00
lines and 2 diagonals interwoven with horizontal wires, fixed with GI
staples, turn buckles etc complete as per clause 800.7 as per
specifications. MORTH Specification No. 807 (PWD SR2011-12/P.No.
194/24.22)

24.23 KSRRB M800-19. Fencing with Welded Steel Wire Fabric 75 mm x 50


mm :- Providing 1.20 metre high fencing with angle iron posts 50 mm x 50
mm x 6 mm at 3 metres center to center with 0.40 metre embedded in
M15 grade cement concrete, corner end and every 10th post to be
strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or
m 593.00
75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and
bolts etc., complete in all respects as per clause 800.7 as per
specifications. MORTH Specification No Suggestive (PWD SR2011-
12/P.No. 194/24.23)

24.24 KSRRB M800-20. Tubular Steel Railing on Medium Weight Steel


Channel (ISMC Series) 100 mm x 50 mm:- Providing fixing and erecting
50 mm dia steel pipe railling in 3 rows duly painted on medium weight steel
channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground,
m 1154.00
2 m centre to centre, complete as per approved drawings as per
specifications. MORTH Specification No 808. (PWD SR2011-12/P.No.
194/24.24)

24.25 KSRRB M800-21. Tubular Steel Railing on Precast RCC Posts, 1.2 m
High Above Ground Level:- Providing, fencing and erecting 50 mm dia
painted steel pipe railing in 3 rows on precast M-20 Grade RCC vertical
posts 1.8 metres high (1.2 m above GL) with 3 holes 50 mm dia for pipe, m 833.00
fixed 2 metres centre to, complete as per approved drawings as per
specifications. MORTH Specification No 808. (PWD SR2011-12/P.No.
195/24.25)

KSRRB M800-Crash Barrier


24.26 KSRRB M800-22. Reinforced cement Concrete Crash Barrier:-
Provision of an Reinforced cement concrete crash barrier at the edges of
the road, approaches to bridges structures and medians, constructed with
M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and
dowel bars 25 mm dia, 450 mm long at expanshion joints filled with pre-
moulded asphalt filler board, keyed to the structure on which it is built and
installed as per design given in the enclousure to MOST circular No. RW / m 2744.00
NH - 33022/1/194-DO III dated 24 june 1994 as per dimensions in the
approved drawing and at locaions directed by the Engineer, all as
specified complete as per approved drawings as per specifications.
MORTH Specification No 809. (PWD SR2011-12/P.No. 195/24.26)

24.27 KSRRB M800-23.1. Metal Beam Crash Barrier:- Providing and erecting a
"W" metal beam crash barrier comprising of 3 mm thick corrugated
sheet ,metal beam rail, 70 cm above road / ground level, fixed on ISMC
series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre,
1.8 m high, 1.1 m below ground / road level, all steel parts and fitments to
be galvanished by hot dip process, all fittings to conform to IS: 1367 and
IS: 1364, metal beam rail to be fixed on the vertical post with a spacer of m 2073.00
channel section 150 x 75 x 5 mm, 330 m long complete as per clause
800.10 complete as per specifications. A. Type-A, "W" MORTH
Specification No 810. (PWD SR2011-12/P.No. 195/24.27)

24.28 KSRRB M800-23.2. Metal Beam Crash Barrier:- Providing and erecting a
"Thrie" metal beam crash barrier comprising of 3 mm thick corrugated
sheet ,metal beam rail, 85 cm above road / ground level, fixed on ISMC
series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre,
2 m high, 1.15 m below ground level, all steel parts and fitments to be
galvanished by hot dip process, all fittings to conform to IS: 1367 and IS: m 3230.00
1364, metal beam rail to be fixed on the vertical post with a spacer of
channel section 150 x 75 x 5 mm, 546 m long complete as per clause
800.10 complete as per specifications. B. Type-B, "Thrie" MORTH
Specification No 810. (PWD SR2011-12/P.No. 195/24.28)

24.29 KSRRB M800-24. Flexible Crash Barrier, Wire Ropes Safety Barrier:-
Providing and erecting a wire rope safety barrier with vertical posts of
medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m),
1.50 m long 0.85 m above ground and 0.65 m below ground level, split at
the bottom for better grip, embedded in M-15 Grade cement concrete 450
x 450 x 450 mm, 1.50 m center to center and with 4 horizontal steel wire
rope 40 mm dia and anchored at terminal posts 15 m apart. Terminal post
to be embedded in M 15 grade cement concrete foundation 2400 x 2400 x
450x 900 mm (depth), strengthened by a strut of RS joist 100 mm x 75 m 1977.00
mm, 2 m long at 45' inclination and a tie 100 x 8 mm, 1.50 m long at the
bottom, all embedded in foundation concrete as per approved design and
drawing, rate excluding excavation and cement concrete complete as per
specifications. MORTH Specification No Suggestive. (PWD SR2011-
12/P.No. 195/24.29)
KSRRB M800-Anti-Glare devices in Median
24.30 KSRRB M800-26.2. Providing and erecting an Anti-Glare screen with 25
mm dia vertical pipes fabricated and framed in the form of panels of one
metre length and 1.75 metre height fixed with circular vane 250 mm dia at
top abd rectangular vane 600 x 300 mm at the middle, made out of steel
sheet of 3 mm thickness, end vertical pipes of the panel made larger for
embedding in foundation concrete, applying 2 coats of paint on all Each 4701.00
exposed surfaces, all as per approved design and drawings complete as
per specifications. B. Anti-glare screen with 25 mm steel pipe framework
fixed with circular and rectangular vanes. MORTH Specification No.
Suggestive (PWD SR2011-12/P.No. 196/30)

24.31 KSRRB M800-26.3. Providing and erecting an Anti-Glare screen with


rectangular vanes of size 750 x 500 mm made from MS sheet, 3 mm thick
and fixed on MS angle 50 x 50 x 6 mm at an angle of 45' to the direction
of flow of traffic, 1.5 m center to center, top edge of the screen 1.75 m
above ground level, vertical post firmly embedded in M-15 cement
concrete foundation 0.60 m below ground level, applying 2 coats of paint m 808.00
on exposed faces, all complete as per approved design and drawings
complete as per specifications. C. Anti-glare screen with rectangular vane
MS sheet. MORTH Specification No. Suggestive (PWD SR2011-12/P.No.
196/31)

KSRRB M800 - Street lighting


24.32 KSRRB M800 - 27. Providing and erecting Street light mounted on a steel
circular hollow pole of standard specifications for street lighting, 9 m high
spaced 40 m apart, 1.8 m overhang on both sides if fixed in the median
and on one side if fixed on the footpath, fitted with sodium vapour lamp
Each 10943.00
and fixed firmly in concrete foundation complete as per specifications.
MORTH Specification No. Suggestive. (PWD SR2011-12/P.No. 196/24.32)

24.33 KSRRB M800 - 28. Lighting On Bridges:- Providing and fixing lighting on
bridges, mounted on steel hollow circular poles of standard specifications,
5 m high fixed on parpets with cement concrete, 20 m apart and fitted with
sodium vapour lamp complete as per specifications. MORTH Specification Each 7162.00
No. Suggestive. (PWD SR2011-12/P.No. 196/24.33)

KSRRB M800 - Cable Duct Across the Road


24.34 KSRRB M800 - 29.1. Providing and laying of a reinforced cement
Concrete pipe duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to toe of slope in fills,
constructing head walls at both ends, providing a minimum fill of fills,
constructing head walls at both ends, providing a minimum fill of granular
material over top and sides of RCC pipe as per IRC: 98-1997, bedded on a
0.3 m thick layer of granular material free of rock pieces, outer to outer
distance of pipe at least half dia of pipe subject to minimum 450 mm in m 1507.00
case of double and triple row ducts, joints to be made leak proof, invert
level of duct to be above higher than ground level to prevent entry of
water and dirt, all as per IRC: 98 - 1997 and approved drawings complete
as per specifications. Case-1: Single row for one utility service (PWD
SR2011-12/P.No. 197/24.34)

24.35 KSRRB M800 - 29.2. Providing and laying of a reinforced cement


Concrete pipe duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to toe of slope in fills,
constructing head walls at both ends, providing a minimum fill of fills,
constructing head walls at both ends, providing a minimum fill of granular
material over top and sides of RCC pipe as per IRC: 98-1997, bedded on a
0.3 m thick layer of granular material free of rock pieces, outer to outer
distance of pipe at least half dia of pipe subject to minimum 450 mm in m 2859.00
case of double and triple row ducts, joints to be made leak proof, invert
level of duct to be above higher than ground level to prevent entry of
water and dirt, all as per IRC: 98 - 1997 and approved drawings complete
as per specifications. Case-II : Double row for two utility services (PWD
SR2011-12/P.No. 197/24.35)

24.36 KSRRB M800 - 29.3. Providing and laying of a reinforced cement


Concrete pipe duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to toe of slope in fills,
constructing head walls at both ends, providing a minimum fill of fills,
constructing head walls at both ends, providing a minimum fill of granular
material over top and sides of RCC pipe as per IRC: 98-1997, bedded on a
0.3 m thick layer of granular material free of rock pieces, outer to outer
distance of pipe at least half dia of pipe subject to minimum 450 mm in m 4224.00
case of double and triple row ducts, joints to be made leak proof, invert
level of duct to be above higher than ground level to prevent entry of
water and dirt, all as per IRC: 98 - 1997 and approved drawings complete
as per specifications. Case-III : Triple row for three utility services (PWD
SR2011-12/P.No. 197/24.36)

KSRRB M800- Gantry mounted variable message sign board


24.37 KSRRB M800-33.1. Providing and erecting Gantry mounted variable
message sign board electronically operated capable of flashing the desired
message over a designed support system of aluminium alloy of
galvanished steel, erected as per approved design and drawings and with Tonne 68213.00
lateral clearance as per clause 800.2.3 complete as per specifications i)
Gantry Support System (PWD SR2011-12/P.No. 197/24.37)
KSRRB M800-34 Traffic Input attenuators at abutments and piers
24.38 KSRRB M800-34.1. Providing and installation of Traffic attenuators at
abutment / pier of flyovers bridges using scrap tyres of size
100 x 20 retrieved from trucks laid in 2 rows and 4 tiers, one above
the other and tied with 20 mm wire rope as per approved design and Sqm 1355.00
drawings complete as per specifications (PWD SR2011-12/P.No.
197/24.38)

24.39 KSRRB M800-34.2. Providing and installation of Traffic impact attenuators


at abutment / pier of flyovers bridges using plastic / steel barrels 0.60 m
dia and 1.0 m in height, filled with sand in three rows and tied with 20 mm
wire rope as per approved design and drawings complete as per Sqm 847.00
specifications B. Using Plastic / Steel Barrel, Filled with sand. (PWD
SR2011-12/P.No. 197/24.39)

24.40 KSRRB M800-34.3. Providing and installing a patentend HI - DRO cell


system as a Traffic impact attenuators, using plastic tubes 50 cm dia, 1.2
m in height, 25 mm opening at the top, placed in three rows, filled with
water and tied with a 20 mm steel wire rope complete as per
specifications. (In this patented HI - DRO cell system, water gets Sqm 749.00
discharged from plastic tubes on impact over a pre-determined time, thus
absorbing the energy) C. With HI - DRO Cell Sandwich (Patented) (PWD
SR2011-12/P.No. 197/24.40)

KSRRB M800 Road Markers / Road Stud


24.41 KSRRB M800-35. Providing and fixing of road stud 100 x 100 mm, die-
cast in aluminium, resistant to corrosive effect of salt and grit, fitted with
lense reflectors, installled in concrete or asphaltic surface by drilling hole
30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout Nos 269.00
or epoxy mortar, all as per BS: 873 part 4:1973 Complete as per
specifications (PWD SR2011-12/P.No. 197/24.41)

KSRRB M800 - Traffic cone


24.42 KSRRB M800 - 36. Provision of red flurescent with white reflective sleeve
traffic cone made of low density polyethylene (LDPE) material with a
square base of 390 x 390 x 35 mm and a height of 770 mm, 4 kg in Nos 482.00
weight, placed at 1.5 m interval, all as per BS: 873 complete as per
specifications (PWD SR2011-12/P.No. 198/24.42)

KSRRb M800- Policeman umbrella


24.43 KRRRB M800-39. Provosion of a 2 m high (floor to roof) umbrella for traffic
policeman at road crossings. where necessay, installed on a raised
platform, built on a central support of a steel pipe 100 mm dia, roof made
of 25 mm dia steel pipe to provide covered area of 3 sqm, roofed with CGI Nos 2260.00
sheets, all steel parts to be given 2 coats of paint complete as per
specifictions. (PWD SR2011-12/P.No. 198/24.43)

KSRRB M800-Portable barricade in construction zone


24.44 KSRRB M800-43. Installation of a steel Portable barricade with horizontal
rail 300 mm wide, 2.5 m in length fitted on a 'A' frame made with 45 X 45
X 5 mm angle iron section, 1.5 m in height, horizontal rail painted (2 coats)
with yellow and white stripes, 150 mm in width at an angle of 45', 'A' frame Each 2050.00
painted with 2 coats of yellow paint, complete as per IRC: SP:55-2001
complete as per specifications. (PWD SR2011-12/P.No. 198/24.44)

KSRRB M800-Permanent type barricade in construction zone


24.45 KSRRB M800-44.1. Construction of a permanent type barricade made of
steel components,1.5 m high from road level, fitted woth 3 horizontal rails
200 mm wide and 4 m long on 50 X 50 X 5 mm angle iron vertical support,
painted with yellow and white stripes, 150 mm in width at an angle of 45',
Each 3226.00
complete as per IRC: SP:55-2001 complete as per specifications.A. With
steel components (PWD SR2011-12/P.No. 198/24.45)

24.46 KSRRB M800-44.2. Construction of a permanent type barricade made of


wooden components,1.5 m high from road level, fitted woth 3 horizontal
planks 200 mm wide and 3.66 m long on 100 X 100 mm wooden vertical
post, painted with yellow and white stripes, 150 mm in width at an angle of
Each 4669.00
45', complete as per IRC: SP:55-2001 complete as per specifications.B.
With Wooden components (PWD SR2011-12/P.No. 198/24.46)

24.47 KSRRB M800-44.3. Construction of a permanent type barricade made with


brick work in mud mortar,1.5 m high, 4 m long, 600 mm thick, plastered
with cement mortar 1:6, painted with yellow and white stripes, complete as Each 10563.00
per specifications.C. With Bricks (PWD SR2011-12/P.No. 198/24.47)

KSRRB M800-Drum delineator in construction zone


24.48 KSRRB M800-45. Provision of metal drum / empty bitumen drum
delineator, 300 mm in diameter, 800 mm high, filled with earth for stability,
painted in circumferntial strips of alternate black and white 100 mm wide
fitted with reflectors 3 nos of 7.5 cm dia, all as per IRC: SP:55-2001 Each 344.00
complete as per specifications. (PWD SR2011-12/P.No. 199/24.48)

KSRRB M800-Flagman
24.49 KSRRB M800-46. Positioning of a smart Flagman with a yellow vest and a
yellow cap and a red flag 600 x 600 mm securely fastened to a staff 1 m in
length for guiding the traffic complete as per specifications (PWD SR2011- Each 261.00
12/P.No. 199/24.49)

24.50 Supplying and fixing in position new guard stones of granite / trap / sand
stone / shahabad roughly dressed, of size 700 mm x 200 mm x 200 mm
including excavation, painting with white and black paint 15 cm wide strip Each 148.00
alternatively etc., complete (PWD SR2011-12/P.No. 199/24.50)
24.51 Removing and varifying guard stones / KM stones/ boundary stones, in a
complete manner embedded in earth excluding painting.(PWD SR2011- Each 22.65
12/P.No. 199/24.51)
BRIDGES - PILE FOUNDATION
Sl. Description Rate
Unit
No. Rs. Ps.
KSRRB 1100-Bored / Cast-in-situ R.C.C. Piles
25.1 KSRRB 1100-1 Bored / Cast-in-situ R.C.C. 1000mm dia. Piles with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @ 0.69cum and fine aggregates @
0.46cum, with superplastisiser @ 3lts confirming to IS9103-1999 cost of all m 14206.00
materials, labour, HOM of machineries complete as per specifications.
MORTH/ Chapter 12 (PWD SR 2011-12/P.No. 201/25.1)

25.1.1 -do- M30, 1000mm dia piles m 15940.00

25.1.2 -do- M35, 1000mm dia piles m 17250.00

25..2 KSRRB 1100-2 Driving cast-in-place vertical R.C.C. 500mm dia. Piles with
OPC cement design mix M20 @ 320kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.69cum and fine aggregates
@ 0.46 cum, with superplastisiser @ 3lts confirming to IS9103-1999 m 4910.00
Reaffirmed-2008 excluding reinforcement as per drawings including cost of
all materials, labour, HOM of machineries complete as per specifications.
MORTH/Chapter 12 (PWD SR 2011-12/P.No. 201/25.2)

25.2.1 -do- M30, 500mm dia piles m 5510.00

25.2.2 -do- M35, 500mm dia piles m 5970.00

25.3 KSRRB M1100-3.1 Bored cast-in-situ R.C.C. pile with OPC Cement design
mix @ 390 kgs, with 20mm and down size graded granite metal coarse
aggregates @ 3lts confirming to IS9103-1999 Reaffirmed-2008, excluding
Reinforcement complete as per Drawing and technical Specifications and
removal of excavated earth with all lifts and lead upto 1000m complete as m 4330.00
per specifications.A.Pile diametre= 750mm MORTH Specification No.1100
& 1700 (PWD SR 2011-12/P.No. 201/25.3)

25.4 KSRRB M1100-3.2. -do- B. pile diameter = 1000mm MORTH Specification


No.1100, 1600 & 1700. (PWD SR 2011-12/P.No. 201/25.4) m 7131.00

25.5 KSRRB M1100-3.3. -do- C. pile diameter = 1200mm MORTH Specification


No.1100 & 1700. (PWD SR 2011-12/P.No. 201/25.5) m 9198.00
25.6 KSRRB M1100-4.1. Driven cast-in--place vertical R.C.C. pile with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @ 0.68 cum and fine aggregates @
0.45cum , with superplastisiser @ 3lts confirming to IS 9103-1999
Reaffirmed -2008, excluding Reinforcement complete as per Drawing and m 3441.00
& Technical specification complete as per specifications. pile diametre=
750 mm. MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No.
201/25.6)

25.7 KSRRB M1100-4.2. -do- pile diameter = 1000mm MORTH Specification


No.1100 & 1700. (PWD SR 2011-12/P.No. 201/25.7) m 5536.00

25.8 KSRRB M1100-4.3. -do- pile diameter = 1200mm MORTH Specification


No.1100 & 1700. (PWD SR 2011-12/P.No. 201/25.8) m 8079.00

25.9 KSRRB M1100-4.4. Driven precast vertical R.C.C. pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.68 cum and fine aggregates @ 0.45cum ,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reaffirmed -2008,
excluding Reinforcement complete as per Drawing and & Technical m 1556.00
specification complete as per specifications. pile diametre= 500 mm.
MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No. 202/25.9)

25.10 KSRRB M1100-4.5. Driven precast vertical R.C.C. pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.68 cum and fine aggregates @ 0.45cum ,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reaffirmed -2008,
excluding Reinforcement complete as per Drawing and & Technical m 2686.00
specification complete as per specifications. pile diametre= 750 mm.
MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No.
202/25.10)

25.11 KSRRB M1100-4.6. Driven precast vertical R.C.C. pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.68 cum and fine aggregates @ 0.45cum ,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reaffirmed -2008,
excluding Reinforcement complete as per Drawing and & Technical m 4504.00
specification complete as per specifications. pile diametre= 1000 mm.
MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No.
202/25.11)

25.12 KSRRB M1100-4.7. Driven precast vertical R.C.C. pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.68 cum and fine aggregates @ 0.45cum ,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reaffirmed -2008,
excluding Reinforcement complete as per Drawing and & Technical m 1041.00
specification complete as per specifications. pile diametre= 1000 mm.
MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No.
202/25.11)
25.13 KSRRB M1100-4.8. Driven precast vertical R.C.C. pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.68 cum and fine aggregates @ 0.45cum ,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reaffirmed -2008,
excluding Reinforcement complete as per Drawing and & Technical m 1749.00
specification complete as per specifications. size of pile diametre= 500mm
x 500mm. MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No.
202/25.13)

25.14 KSRRB M1100-4.9. Driven precast vertical R.C.C. pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.68 cum and fine aggregates @ 0.45cum ,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reaffirmed -2008,
excluding Reinforcement complete as per Drawing and & Technical m 3393.00
specification complete as per specifications. size of pile diametre= 750mm
x 750mm. MORTH Specification No.1100 & 1700 (PWD SR 2011-12/P.No.
202/25.14)

25.15 KSRRB M1100-5, Driven Vertical Steel piles as per Drawing and &
Technical Specification complete as per specifications. Section of the pile
= H section steel column 400x250 mm (ISHB series) MORTH Specification m 4433.00
No. 1100 & 1900 (PWD SR 2011-12/P.No. 202/25.15)

25.16 KSRRB M1100-6, Driven Vertical Steel piles as per Drawing and &
Technical Specification complete as per specifications. Section of the pile
= H section steel column 450x250 mm (ISHB series) MORTH Specification m 5002.00
No. 1100 & 1900.(PWD SR 2011-12/P.No. 202/25.16)

25.18 KSRRB M1100-8.1. Cement Concrete for Reinforced Concrete in pile cap
as per Drawing and Technical Specification complete as per
Specifications. A.RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3lts confirming to m 4152.00
IS 9103-1999 Reaffirmed-2008 Case-|: Using Concrete Mixer MORTH
Specification No.1100,1500 & 1700 (PWD SR 2011-12/P.No. 202/25.18)

25.19 KSRRB M1100-8.2. Cement Concrete for Reinforced Concrete in pile cap
as per Drawing and Technical Specification complete as per
Specifications. A.RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3lts confirming to Cum 4094.00
IS 9103-1999 Reaffirmed-2008 Case-|: Using Concrete Mixer MORTH
Specification No.1100,1500 & 1700 (PWD SR 2011-12/P.No. 202/25.19)
25.20 KSRRB M1100-9.1. Cement Concrete for Reinforced Concrete in pile Cap
as per Drawing and Technical Specification complete as per
Specifications. B. RCC with OPC cement design mix @ 340 kgs, with
20mm and Down size graded granite metal coarse aggregates @ 0.7cum
and fine aggregates @ 0.47 cum, with superplastisiser @ 3lts confirming Cum 4308.00
to IS 9103-1999 Refirmed-2009. Case-| Using concrete mixer MORTH
Specification No. 1500 & 1700. (PWD SR 2011-12/P.No. 203/25.20)

25.21 KSRRB M1100-9.2. Cement Concrete for Reinforced Concrete in pile Cap
as per Drawing and Technical Specification complete as per
Specifications. B. RCC with OPC Cement design mix M25 @ 340kgs, with
20mm and down size graded metal coarse aggregates @ 0.7 Cum and
fine aggregates @ 0.47 cum, with superplastisiser @ 3lts confirming to Cum 4298.00
IS9103-1999 Reafirmed-2009, Case-||: Using Batching plant, Transit Mixer
and Concrete Pump MORTH Specification No. 1100, 1500 & 1700 (PWD
SR 2011-12/P.No. 203/25.21)

25.22 KSRRB M1100-10.1. Cement Concrete for Reinforced Concrete in pile


Cap as per Drawing and Technical Specification complete as per
Specifications. C. RCC with OPC cement design mix M30 @ 360 kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46 cum, with superplastisiser @ 3lts confirming Cum 4435.00
to IS9103-1999 Reafirmed - 2008. Case-|: Using Concrete Mixer MORTH
specification No. 1100,1500 & 1700 (PWD SR 2011-12/P.No. 203/25.22)

25.23 KSRRB M1100-10.2. Cement Concrete for Reinforced Concrete in pile


Cap as per Drawing and Technical Specification complete as per
Specifications. C. RCC with OPC cement design mix M30 @ 360 kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46 cum, with superplastisiser @ 3lts confirming Cum 4430.00
to IS9103-1999 Reafirmed - 2008. Case-||: Usinf batching plant. Transit
Mixer and Concrete Pump MORTH Specification No. 1100,1500 & 1700.
(PWD SR 2011-12/P.No. 203/25.23)

25.24 KSRRB M1100-11.1. Cement Concrete for Reinforced Concrete in pile


Cap as per Drawing and Technical Specification complete as per
Specifications. D. RCC with OPC cement design mix M35 @ 390 kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.68 cum
and fine aggregates @ 0.45 cum, with superplastisiser @ 3lts confirming Cum 4619.00
to IS 9103-1999 Reafirmed-2008. Case-|: Using Concrete Mixer MORTH
Specification No. 1100, 1500 & 1700. (PWD SR 2011-12/P.No. 203/25.24)
25.25 KSRRB M1100-11.2. Cement Concrete for Reinforced Concrete in pile
Cap as per Drawing and Technical Specification complete as per
Specifications. D. RCC with OPC cement design mix M35 @ 390 kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.68 cum
and fine aggregates @ 0.45 cum, with superplastisiser @ 3lts confirming Cum 4621.00
to IS 9103-1999 Reafirmed-2008. Case-||: Using Batching Plant, Transit
Mixer and Concrete Pump. MORTH Specification No. 1100, 1500 & 1700.
(PWD SR 2011-12/P.No. 203/25.25)

KSRRB M1100- Levelling course For Pile cap


25.26 KSRRB M1100-12. Providing and laying of PCC M 15 levelling course
100mm thick below the pile cap complete as per specifications MORTH Cum 3148.00
Specification No. 1100 & 1700 (PWD SR 2011-12/P.No. 204/25.26)

KSRRB M1100-13. Supplying, Fitting and placing un-coated HYSD


bar/MS Bar
25.27 KSRRB M1100-13, Supplying, Fitting and Placing un-coated TMT bar
Reinforcement in Foundation as per Drawing and Technical Specifications
complete as per Specification No. 1600 (PWD SR 2011-12/P.No. Tonne 54476.00
204/25.27)

25.28 KSRRB M1100-14, Supplying, fitting and placing un-coated Mild Steel
Reinforcement in foundation as per drawing and technical Specification
Complete as per Specifications. MORTH Specification No. 1600. (PWD SR Tonne 54019.00
2011-12/P.No. 204/25.28)
BRIDGES - WELL FOUNDATION
Sl. Description Rate
Unit
No. Rs. Ps.

KSRRB M1200-Temporary Island


26.1 KSRRB 1200-1.1 : Providing, and Constructing Temporary Island 16 m
diameter for Construction of well Foundation for 8m dia Well complete as
per specifications. MORT & H Specification No. 1200 (PWD SR2011- No 67297.00
12/P.No. 206/26.1)

26.2 KSRRB 1200-1.2: Providing, and Constructing Temporary Island 16 m


diameter for Construction of well Foundation for 8m dia Well complete as
per specifications. B. Assuming depth of water 4.0 m and high of island 4.5 No 487630.00
m MORT & H Specification No. 1200 (PWD SR2011-12/P.No.
206/26.2)

26.3 KSRRB 1200-1.3 : Providing, and Constructing Temporary Island 16 m


diameter for Construction of well Foundation for 8m dia Well complete as
per specifications. C. Providing and constructing one span service road to
reach island location from one pier location to another pier location- m 2128.00
Assuming span length 30m, width of service road 10 m & depth of water 1
m MORT & H Specification No. 1200 (PWD SR2011-12/P.No.
206/26.3)

KSRRB M1200- Providing and Laying Cutting Edge of Mild Steel


26.4 KSRRB 1200-2 : Providing, and Laying Cutting Edge of Mild Steel
weighing 40 kgper metre for Well Foundation complete as per Drawing
and technical Specification complete as per specifications. MORT & H Tonne 58533.00
Specification No. 1200 & 1900 (PWD SR2011-12/P.No. 206/26.4)

KSRRB M1200-Plain / Reinforced Cement Comcrete


26.5 KSRRB 1200-3.1 : Plain / Reinforced Cement Concrete, in Well
Foundation Complete as per Drawing and Technical Specification.
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2011-12/P.No.
206/26.5)

26.5.1 KSRRB 1200-3.1 : i) RCC with OPC cement design mix M20 @ 320kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.69cum and fine aggregates @ 0.47 cum, with superplastisiser @ 3lts Cum 4993.00
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No.
206/26.5.1)

26.5.2 KSRRB 1200-3.2 : ii) RCC with OPC cement design mix M25 @ 340kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.7cum and fine aggregates @ 0.47 cum, with superplastisiser @ 3lts Cum 5184.00
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No.
206/26.5.2)
26.5.3 KSRRB 1200-3.3 : iii) RCC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.68cum and fine aggregates @ 0.45 cum, with superplastisiser @ 3lts Cum 5553.00
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No.
206/26.5.3)

26.5.4 KSRRB 1200-4.1 : i) PCC Design mix M15 with OPC cement @ 240kgs,
with 40mm and down size graded granite metal coarse aggregates @
0.63cum and fine aggregates @ 0.42 cum (PWD SR2011-12/P.No. Cum 3649.00
206/26.5.4)

26.5.5 KSRRB 1200-4.2 : ii) PCC with OPC cement design mix M20 @ 300kgs,
with 40mm and down size graded granite metal coarse aggregates @
0.64cum and fine aggregates @ 0.43 cum with superplastisiser @ 3lts Cum 4295.00
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No.
206/26.5.5)

26.5.6 KSRRB 1200-4.3 : iii) RCC with OPC cement design mix M20 @ 320kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.69cum and fine aggregates @ 0.46 cum with superplastisiser @ 3lts
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No. Cum 4598.00
207/26.5.6)

26.5.7 KSRRB 1200-4.4 : iv) PCC with OPC cement design mix M25 @ 340kgs,
with 40mm and down size graded granite metal coarse aggregates @
0.7cum and fine aggregates @ 0.47 cum with superplastisiser @ 3lts
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No. Cum 4707.00
207/26.5.7)

26.5.8 KSRRB 1200-4.5 : v) RCC with OPC cement design mix M25 @ 340kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.7cum and fine aggregates @ 0.47 cum with superplastisiser @ 3lts
Cum 4773.00
confirming to IS 9103-1999 Reafirmed-2008 (PWD SR2011-12/P.No.
207/26.5.8)

26.5.9 KSRRB 1200-4.6 : vi) PCC with OPC cement design mix M30 @ 360kgs,
with 40mm and down size graded granite metal coarse aggregates @
0.69um and fine aggregates @ 0.46 cum with superplastisiser @ 3lts
Cum 4840.00
confirming to IS 9103-1999 Reaffirmed-2008 (PWD SR2011-12/P.No.
207/26.5.9)

26.5.10 KSRRB 1200-4.7 : vii) RCC with OPC cement design mix M30 @ 360kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.69um and fine aggregates @ 0.46 cum with superplastisiser @ 3lts
Cum 4903.00
confirming to IS 9103-1999 Reaffirmed-2008 (PWD SR2011-12/P.No.
207/26.5.10)
26.5.11 KSRRB 1200-4.8 : viii) RCC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.68um and fine aggregates @ 0.45 cum with superplastisiser @ 3lts
confirming to IS 9103-1999 Reaffirmed-2008 (PWD SR2011-12/P.No. Cum 5111.00
207/26.5.11)

26.5.12 KSRRB 1200-4.8 : ix) RCC with OPC cement design mix M40 @ 420kgs,
with 20mm and down size graded granite metal coarse aggregates @
0.67um and fine aggregates @ 0.44 cum with superplastisiser @ 3lts
Cum 5071.00
confirming to IS 9103-1999 Reaffirmed-2008 (PWD SR2011-12/P.No.
207/26.5.12)

26.6 KSRRB 1200-5.1 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
Concrete to be placed using termile pipe.C) Bottom Plug i) PCC with 43
cement design mix M20 @ 320kgs, with 40mm and down size graded
granite metal coarse aggregates @ 0.69cum and fine aggregates @ Cum 4229.00
0.46 cum, with superplastisiser @ 3lts confirming to IS 9103-1999
Reafirmed-2008, Case-| Using Concrete Mixer, MORTH Specification
No. 1200, 1500 & 1700 (PWD SR2011-12/P.No. 207/26.6)

26.7 KSRRB 1200-5.2 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
Concrete to be placed using termile pipe. i) PCC with OPC cement
design mix M20 @ 320kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.69cum and fine aggregates @ 0.46 cum,
with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed- Cum 3916.03
2008, Case-|| Using Batching Plant, Transit Mxer and Crane /
Concrete pump MORTH Specification No. 1200, 1500 & 1700 (PWD
SR2011-12/P.No. 207/26.7)

26.8 KSRRB 1200-6.1 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
Concrete to be placed using termile pipe. ii) PCC with OPC cement
design mix M25 @ 340kgs, with 40mm and down size graded granite
metal coarse aggregates @ 0.7cum and fine aggregates @ 0.47 cum, Cum 4623.00
with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, Case-| Using Concrete Mixer, MORTH Specification No. 1200,
1500 & 1700 (PWD SR2011-12/P.No. 208/26.8)

26.9 KSRRB 1200-6.2 : Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification.
Concrete to be placed using termile pipe: PCC with OPC cement design
mix M25 @ 340kgs, with 40mm and down size graded granite metal
coarse aggregates @ 0.7cum and fine aggregates @ 0.47 cum, with
Cum 4316.00
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008,
Case-|| Using Batching Plant, Transit Mixer and Crane / Concrete
pump, MORTH Specification No. 1200, 1500 & 1700 (PWD SR2011-
12/P.No. 208/26.9)
26.10 KSRRB 1200-7.1: Plain / Reinforced Cement Concrete, in Well Foundation
Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iii) PCC with OPC cement design mix M25 @
360kgs, with 20mm and down size graded granite metal coarse
aggregates @ 0.69cum and fine aggregates @ 0.46 cum, with Cum 5301.00
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008,
Case-| Using Concrete Mixer, MORTH Specification No. 1200, 1500 &
1700(PWD SR2011-12/P.No. 208/26.10)

26.11 KSRRB 1200-7.2: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. PCC with OPC cement design mix M30 @
360kgs, with 40mm and down size graded granite metal coarse
aggregates @ 0.69cum and fine aggregates @ 0.46 cum, with
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008, Cum 4440.00
Case-| Using Batching Plant, Transit Mixer and Crane / Concrete pump,,
MORTH Specification No. 1200, 1500 & 1700(PWD SR2011-12/P.No.
208/26.11)

26.12 KSRRB 1200-8.1: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iv) PCC with OPC cement design mix M35 @
390kgs, with 40mm and down size graded granite metal coarse
aggregates @ 0.68cum and fine aggregates @ 0.45 cum, with
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008, Cum 5526.00
Case-| Using Concrete Mixer, MORTH Specification No. 1200, 1500 &
1700(PWD SR2011-12/P.No. 208/26.12)

26.13 KSRRB 1200-8.2: Plain / Reinforced Cement Concrete, in Well Foundation


Complete as per Drawing and Technical Specification. Concrete to be
placed using termile pipe. iv) PCC with OPC cement design mix M35 @
390kgs, with 40mm and down size graded granite metal coarse
aggregates @ 0.68cum and fine aggregates @ 0.45 cum, with
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008, Cum 4638.00
Case-|| Using Batching Plant, Transit Mixer and Crane / Concrete pump,
MORTH Specification No. 1200, 1500 & 1700(PWD SR2011-12/P.No.
208/26.13)

D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well


Foundation
26.14 KSRRB M1200-9.1. (i) PCC with OPC cement design mix M20 @
320kgs, with 40mm and down size graded granite metal coarse
aggregates @ 0.69cum and fine aggregates @ 0.46 cum, with
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008, Cum 4043.00
Same as in bottom plug concrete etc., MORTH Specification No. 1200,
1500 & 1700 (PWD SR2011-12/P.No. 209/26.14)

26.15 D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well


Foundation MORTH Specification No. 1200, 1500 & 1700.
26.15.1 KSRRB M1200-9.2. (ii) PCC with OPC cement design mix M25 @ 340kgs,
with 40mm down size graded granite metal coarse aggregates @ 0.7 Cum
and fine aggregates @ 0.47 cum, with superplastisiser @3lts Confirming Cum 4419.00
to IS 9103-1999 Reaffirmed-2008 (PWD SR2011-12/P.No. 109/26.15.1)

26.15.2 KSRRB M1200-9.3. (iii) PCC with OPC cement design mix M30 @ 360kgs,
with 40mm down size graded granite metal coarse aggregates @ 0.69
Cum and fine aggregates @ 0.46 cum, with superplastisiser @3lts Cum 5301.00
Confirming to IS 9103-1999 Reaffirmed-2008 (PWD SR2011-12/P.No.
109/26.15.2)

26.16 E. Top Plug


KSRRB M1200-10.1. (i) PCC design mix M15 with OPC cement @
240kgs, with 40mm down size graded granite metal coarse aggregates @
0.63 Cum and fine aggregates @ 0.42 cum. MORTH Specification No. Cum 3318.00
1200, 1500 & 1700 (PWD SR2011-12/P.No. 209/26.16)

26.17 KSRRB M1200-10.2.(ii) PCC with OPC Cement design mix M20 @
320kgs, with 20mm down size graded granite metal coarse aggregates @
0.69 Cum and fine aggregates @ 0.46 cum. With superplastisiser @ 3lts Cum 3927.00
confirming to IS9103-1999 Reaffirmed-2008. MORTH Specification No.
1200, 1500 & 1700 (PWD SR2011-12/P.No. 209/26.17)

26.18 KSRRB M1200-10.3.(iii) PCC with OPC Cement design mix M25 @
340kgs, with 40mm down size graded granite metal coarse aggregates @
0.7Cum and fine aggregates @ 0.47 cum. With superplastisiser @ 3lts
confirming to IS9103-1999 Reaffirmed-2008. Same item as 2100-11.5. Cum 4302.00
excluding formwork. MORTH Specification No. 1200, 1500 & 1700 (PWD
SR2011-12/P.No. 209/26.18)

26.19 KSRRB M1200-10.4.(iv) PCC with OPC Cement design mix M30 @
360kgs, with 40mm down size graded granite metal coarse aggregates @
0.69Cum and fine aggregates @ 0.46 cum. With superplastisiser @ 3lts
confirming to IS9103-1999 Reaffirmed-2008. Same item as 2100-11.5. Cum 4423.00
excluding formwork. MORTH Specification No. 1200, 1500 & 1700 (PWD
SR2011-12/P.No. 209/26.19)

26.20 KSRRB M1200-11.1 Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specfication F.Well
Cap (i) RCC with OPC Cement design mix M20 @ 320kgs, with 20mm
down size graded granite metal coarse aggregates @ 0.69Cum and fine
Cum 4962.00
aggregates @ 0.46 cum. With superplastisiser @ 3lts confirming to
IS9103-1999 Reaffirmed-2008. Case-| : Using Concrete mixer, MORTH
Specification No. 1200, 1500 & 1700 (PWD SR2011-12/P.No. 209/26.20)
26.21 KSRRB M1200-11.2. Plain / Reinforced Cement Concrete, in Well
Foundation Complete as per Drawing and Technical Specification. (i) RCC
with OPC Cement design mix M20 @ 320kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.69Cum and fine aggregates
@ 0.46 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4111.00
Reaffirmed-2008. Case -II: Using Batching Plant, Transit Mixer and
Crane / Concrete Pump MORTH Specification No. 1200, 1500 & 1700
(PWD SR2011-12/P.No. 210/26.21)

26.22 KSRRB M1200-11.3. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification. (i) RCC
with OPC Cement design mix M20 @ 320kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.69Cum and fine aggregates
@ 0.46 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4351.00
Reaffirmed-2008. Case -I: Using Concrete mixer MORTH Specification No.
1200, 1500 & 1700 (PWD SR2011-12/P.No. 210/26.22)

26.23 KSRRB M1200-11.4. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification. (ii) RCC
with OPC Cement design mix M25 @ 340kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.7Cum and fine aggregates
@ 0.47 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4278.00
Reaffirmed-2008. Case -I: Using Concrete mixer MORTH Specification No.
1200, 1500 & 1700 (PWD SR2011-12/P.No. 210/26.23)

26.24 KSRRB M1200-11.5. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification. (iii)
RCC with OPC Cement design mix M30 @ 360kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.69Cum and fine aggregates
@ 0.46 cum. With superplastisiser @ 3lts confirming to IS9103-1999
Cum 4640.00
Reaffirmed-2008. Case -I: Using Concrete mixer MORTH Specification No.
1200, 1500 & 1700 (PWD SR2011-12/P.No. 210/26.24)

26.25 KSRRB M1200-11.6. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification. RCC
with OPC Cement design mix M30 @ 360kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.69Cum and fine aggregates
@ 0.46 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4381.00
Reaffirmed-2008. Case -II: Using Batching Plant, Transit Mixer and
Crane / Concrete Pump, MORTH Specification No. 1200, 1500 & 1700
(PWD SR2011-12/P.No. 210/26.25)
26.26 KSRRB M1200-11.7. Plain / Reinforced Cement Concrete, in Well
Foundation Complete as per Drawing and Technical Specification. iv) RCC
with OPC Cement design mix M35 @ 390kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.68Cum and fine aggregates
@ 0.45 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4802.00
Reaffirmed-2008. Case -I: Using Concrete mixer, MORTH Specification
No. 1200, 1500 & 1700 (PWD SR2011-12/P.No. 210/26.26)

26.27 KSRRB M1200-11.8. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification. RCC
with OPC Cement design mix M35 @ 390kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.68Cum and fine aggregates
@ 0.45 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4575.00
Reaffirmed-2008. Case -II:Using Batching Plant, Transit Mixer and
Concrete Pump MORTH Specification No. 1200, 1500 & 1700 (PWD
SR2011-12/P.No. 210/26.27)

26.28 KSRRB M1200-12. Plain / Reinforced Cement Concrete, in Well


Foundation Complete as per Drawing and Technical Specification (v)
RCC with OPC Cement design mix M40 @ 420kgs, with 20mm down size
graded granite metal coarse aggregates @ 0.67Cum and fine aggregates
@ 0.44 cum. With superplastisiser @ 3lts confirming to IS9103-1999 Cum 4748.00
Reaffirmed-2008. Using Batching Plant, Transit Mixer and Concrete Pump
MORTH Specification No. 1200, 1500 & 1700 (PWD SR2011-12/P.No.
211/26.28)

KSRRB M1200- Sinking of well in sandy soil


26.29 KSRRB 1200-13.1 : Sinking of 6 m external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 1339.00
bed level complete as per specifications. (i) Depth below bed level upto
3.0 m, Rate of sinking = 0.50 m per hour MORT Specification No.
Section1200 (PWD SR2011-12/P.No. 211/26.29)

26.30 KSRRB 1200-13.2 : Sinking of 3 m upto 10 m depth. external diametre


well (other than pneumatic method of sinking) through all types of strata
namely sandy soil, clayey soil and rock as shown against each case,
complete as per drawings, and technical Specifications. Depth of sinking m 1818.00
is reckoned from bed level complete as per specifications. (ii) Beyond 3 m
upto 10 m, depth, Rate of sinking = 0.33 m per hour MORT & H
Specification No. Section1200 (PWD SR2011-12/P.No. 211/26.30)
26.34 KSRRB 1200-14.1 : Sinking of 7 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. A. Sandy Soil, Diameter of well m 1890.00
= 7m (i) Depth below bed level upto 3.0 m, Rate of sinking = 0.30 m per
hour. MORT & H Specification No. Section1200 (PWD SR2011-12/P.No.
211/26.34)

26.35 KSRRB 1200-14.2 : Sinking of 8m depth metre external diametre well


(other than pneumatic method of sinking) through all types of strata
namely sandy soil, clayey soil and rock as shown against each case,
complete as per drawings, and technical Specifications. Depth of sinking
is reckoned from bed level complete as per specifications. (ii) Beyond 3 m m 2442.00
upto 10 m, depth, Rate of sinking = 0.22 m per hour MORT & H
Specification No. Section1200 (PWD SR2011-12/P.No. 211/26.35)

26.39 KSRRB 1200-15.1 : Sinking of external 8 external diametre well (other


than pneumatic method of sinking) through all types of strata namely
sandy soil, clayey soil and rock as shown against each case, complete as
per drawings, and technical Specifications. Depth of sinking is reckoned
from bed level complete as per specifications. (i) Depth below bed level m 2298.00
upto 3.0 m. Rate of sinking at 0.25 m per hour MORT & H Specification
No. Section1200 (PWD SR2011-12/P.No. 211/26.39)

26.40 KSRRB 1200-15.2 : Sinking of 8 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 2787.00
Rate of sinking at 0.25 m per hour. MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 211/26.40)

26.44 KSRRB 1200-16.1 : Sinking of 9 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. (i) Depth below bed level upto m 2361.00
3.0 m. Rate of sinking at 0.25 m per hour. MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 212/26.44)
26.45 KSRRB 1200-16.2 : Sinking of 9 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 3058.00
Rate of sinking = 0.18 m per hour. MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No.212 /26.45)

26.49 KSRRB 1200-17.1 : Sinking of 10 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. . MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 212/26.49)

26.49.1 KSRRB 1200-17.1 : Sinking of 10 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 2714.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.20 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 212/26.49.1)

26.49.2 KSRRB 1200-17.1 : Sinking of 10 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 3262.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.17 m / hour MORT & H Specification No. Section1200
(PWD SR2011-12/P.No. 212/26.49.2)

26.53 KSRRB 1200-18.1 : Sinking of 11 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 5913.00
bed level complete as per specifications.i) Depth below bed level upto 3.0
m. Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 212/26.53)

26.54 KSRRB 1200-18.2 : Sinking of 11 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 5639.00
bed level complete as per specifications.ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.13 m / hour MORT & H Specification No. Section1200
(PWD SR2011-12/P.No. 212/26.54)
26.58 KSRRB 1200-19.1 : Sinking of 12 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 12764.00
bed level complete as per specifications.i) Depth below bed level upto 3.0
m. Rate of sinking at 0.05 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 212/26.58)

26.59 KSRRB 1200-19.2 : Sinking of 12 metre external diametre well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications.i) Beyond 3 m upto 10 m depth. m 14951.00
Rate of sinking at 0.038 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 212/26.59)

26.63 KSRRB 1200-20.1 : Sinking of Twin D type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level
complete as per specifications. Overall length = 12 m, Overall width = 6 m m 2858.00
i) Depth from bed level upto 3.0 m. Rate of sinking = 0.18 m / hour
MORT & H Specification No. Section1200 (PWD SR2011-12/P.No.
212/26.63)

26.64 KSRRB 1200-20.2 : Sinking of Twin D type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level
complete as per specifications. Overall length = 12 m, Overall width = 6 m m 3114.00
ii) Beyond 3 m upto 10 m depth. Rate of sinking at 0.17 m / hour MORT
& H Specification No. Section1200 (PWD SR2011-12/P.No. 212/26.64)

26.68 KSRRB 1200-21.1 : Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. i) Depth below bed level upto m 1818.00
3.00 m, rate of sinking at 0.33 m per hour. MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.64)
26.69 KSRRB 1200-21.2 : Sinking of 6 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4254.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth,
rate of sinking at 0.17 m per hour. MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.69)

26.73 KSRRB 1200-212.1 : Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. i) Depth below bed level upto 3.0 m 2442.00
m. Rate of sinking = 0.22 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.73)

26.74 KSRRB 1200-22.1 : Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 4248.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 depth.
Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.74)

26.78 KSRRB 1200-23.1 : Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 2985.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.18 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.78)

26.79 KSRRB 1200-23.2 : Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4581.00
bed level complete as per specifications. ii) Beyond 3 m upto10 m depth.
Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.79)

26.83 KSRRB 1200-24.1 : Sinking of 9 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 3184.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.83)
26.84 KSRRB 1200-24.2 : Sinking of 9 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 4926.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.84)

26.88 KSRRB 1200-25.1 : Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 3747.00
bed level complete as per specifications. i) Depth below bed level upto 3.0
m. Rate of sinking = 0.18 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 213/26.88)

26.89 KSRRB 1200-25.2 : Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth. m 5139.00
Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 214/26.89)

26.93 KSRRB 1200-26.1 : Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. i) Depth below bed level upto 3.0 m 6188.00
m. Rate of sinking = 0.10 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 214/26.93)

26.94 KSRRB 1200-26.2 : Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 10806.00
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth.
Rate of sinking = 0.08 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. /26.94)

26.98 KSRRB 1200-27.1 : Sinking of 12 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. i) Depth below bed level upto 3.0 m 14838.00
m. Rate of sinking = 0.04 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 214/26.98)
26.99 KSRRB 1200-27.2 : Sinking of 12 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. ii) Beyond 3 m upto 10 m depth. m 25141.00
Rate of sinking = 0.03 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. /26.99)

26.103 KSRRB 1200-28.1 : Sinking of Twin D Type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level m 3455.00
complete as per specifications. i) Depth below bed level upto 3.0 m. Rate
of sinking = 0.16 m / hour MORT & H Specification No. Section1200
(PWD SR2011-12/P.No. 214/26.103)

26.104 KSRRB 1200-28.2 : Sinking of Twin D Type well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level m 5676.00
complete as per specifications. ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.15 m / hour MORT & H Specification No. Section1200
(PWD SR2011-12/P.No. 214/26.104)

26.107 KSRRB 1200-29 : Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 8443.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m depth. Rate of sinking = 0.25 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 214/26.107)

26.108 KSRRB 1200-30 : Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 6344.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.22 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 214/26.108)

26.109 KSRRB 1200-31 : Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 7088.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.22 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 215/26.109)
26.110 KSRRB 1200-32 : Sinking of 9 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 8202.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 215/26.110)

26.111 KSRRB 1200-33 : Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 9007.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.14 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 215/26.111)

26.112 KSRRB 1200-34 : Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
m 19984.00
bed level complete as per specifications. Depth in soft rock strata upto 3
m . Rate of sinking = 0.06 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 215/26.112)

26.113 KSRRB 1200-35 : Sinking of 12 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. Depth in soft rock strata upto 3 m 44220.00
m . Rate of sinking = 0.025 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 215/26.113)

26.114 KSRRB 1200-36 : Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level
complete as per specifications. Depth in soft rock strata upto 3 m . Rate of m 9832.00
sinking = 0.12 m / hour MORT & H Specification No. Section1200
(PWD SR2011-12/P.No. 215/26.114)

KSRRB M1200 - Hard Rock


26.115 KSRRB 1200-37 : Sinking of 6 m external diameter Well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from
bed level complete as per specifications. Depth in hard rock strata upto 3 m 8130.00
m . Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 215/26.115)

26.116 KSRRB 1200-38 : Sinking of 7 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 10244.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 216/26.116)

26.117 KSRRB 1200-39 : Sinking of 8 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 10631.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.17 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 216/26.117)

26.118 KSRRB 1200-40 : Sinking of 9 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 12173.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.15 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 216/26.118)

26.119 KSRRB 1200-41 : Sinking of 10 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 13201.00
bed level complete as per specifications. Depth in hard rock strata upto 3
m . Rate of sinking = 0.12 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 216/26.119)

26.120 KSRRB 1200-42 : Sinking of 11 m external diameter Well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 29052.00
bed level complete as per specifications.Depth in hard rock strata upto 3
m . Rate of sinking = 0.05 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 216/26.120)
26.121 KSRRB 1200-43 : Sinking of 12 m external diameter Well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per
drawings, and technical Specifications. Depth of sinking is reckoned from m 62106.00
bed level complete as per specifications.Depth in hard rock strata upto 3
m . Rate of sinking = 0.020 m / hour MORT & H Specification No.
Section1200 (PWD SR2011-12/P.No. 216/26.121)

26.122 KSRRB 1200-44 : Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawings, and
technical Specifications. Depth of sinking is reckoned from bed level
complete as per specifications.Depth in hard rock strata upto 3 m . Rate of m 13856.00
sinking = 0.10 m / hour MORT & H Specification No. Section1200
(PWD SR2011-12/P.No. 216/26.122)

26.123 KSRRB 1200-45 : Penumatic Sinking of Wells with equipment of approved


design, drawing and specifications worked by competent and trained
personnel and comprising of decompression chambers, reducers, two air
locks separately for men and plant & materials, arrangment for supply of
fresh air to working chambers, check valves, exhaust valves, shafts made
from steel plates of riveted construction not less than 6 mm thick to
withstand an air pressure of 0.50 Mpa, controlled blasting of hard rock
where required, staircases and 1 m wide landing platforms with railing,
Cum 50207.00
arrangement for compression and decompression, electric lighting of 50 V
maximum, proper rooms for rest and medical examinations and
compliance with safety precautions as per IS: 4138, all as per clause
1200.7.6 of MORT & H Specification No. Section1200 (PWD SR2011-
12/P.No. 217/26.123)

26.124 KSRRB 1200-46 : Sand filling in wells Complete as per drawing and
technical specifications MORT & H Specification No. Section1207 (PWD Cum 1436.00
SR2011-12/P.No. 217/26.124)

26.125 KSRRB 1200-47 : Providing Steel liner 10 mm thick for curbs and 6 mm
thick for seining of wells including fabricating and setting out as per
detailed drawing Complete as per specifications MORT & H Specification Tonne 60310.00
No. Section1207 (PWD SR2011-12/P.No. 217/26.125)

KSRRB M1200-Reinforced Cement concrete for welll curb


26.126 KSRRB M1200-48.1. Construction of cement concrete kerb with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm
projection beyond kerb stone, kerb stone laid with kerb lying machine,
foundation concrete laid manually, all complete as per clause 400.8 m 283.00
complete as per specifications. A. Using Concrete Mixer. MORTH
Specification No.408. (PWD SR2011-12/P.No. 217/26.126)
26.127 KSRRB M1200-48.2. Construction of cement concrete kerb with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm
projection beyond kerb stone, kerb stone laid with kerb lying machine,
foundation concrete laid manually, all complete as per clause 400.8 m 230.00
complete as per specifications. B. Using Concrete Batching and Mixing
Plant. MORTH Specification No.408. (PWD SR2011-12/P.No. 217/26.127)

26.128 KSRRB M1200-49.1. Cast-in-Situ Cement Concrete M 20 kerb with


Channel. Construction of cement concrete kerb with channel with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, kerb channel laid with kerb
lying machine, foundation concrete laid manually, all complete as per m 518.00
clause 400.8 complete as per specifications. A. Using Concrete Mixer
Plant. MORTH Specification No.408. (PWD SR2011-12/P.No. 217/26.128)

26.129 KSRRB M1200-49.2. Cast-in-Situ Cement Concrete M 20 kerb with


Channel. Construction of cement concrete kerb with channel with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, kerb channel laid with kerb
lying machine, foundation concrete laid manually, all complete as per m 439.00
clause 400.8 complete as per specifications. B. Using Concrete Batching
and Mixing Plant. MORTH Specification No.408. (PWD SR2011-12/P.No.
217/26.129)

26.130 Providing and Fixing 3m long 25mm dia TMT dowel bars 1.5m inserted
in50mm dia holes drilled in hard rock and grouting in CM 1:1 including
necessary bending, hooking, cutting and handing charges complete
including the cost of steel. (MORTH clause 1200) (PWD SR2011-12/P.No.
218/26.130)

26.130.1 -do- below LWL in open foundation upto 3m. Each 1069.00

26.130.2 -do- below LBL in open foundation beyond 3m. Each 1179.00

26.130.3 - do- for well foundation below LWL upto 3m. Each 1512.00

26.130.4 -do- for well foundation below LWL beyond 3m. Each 1955.00
BRIDGES - OPEN FOUNDATIONS
KSRRB M2100 - Excavation in Ordinary Soil
27.1 kSRRB M2100 - 1.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
Cum 80.70
approved material complete as per specifications. 1. Ordinary Soil - A.
Manual Means (i) Depth upto 3 m. Morth specification No. 304
(PWD SR2011-12/P.No. 220/27.1)

27.2 kSRRB M2100 - 1.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
approved material complete as per specifications. 1. Ordinary Soil - A. Cum 103.75
Manual Means (ii) 3 m to 6m depth Morth specification No. 304
(PWD SR2011-12/P.No. 220/27.2)

27.3 kSRRB M2100 - 1.3. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 138.30
approved material complete as per specifications. 1. Ordinary Soil - A.
Manual Means (iii) Above 6m depth Morth specification No. 304
(PWD SR2011-12/P.No. 220/27.3)

27.4 "KSRRB M2100-2.1. Earth work in excavation for foundation of structures


as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
Cum 37.95
approved material complete as per specifications B.Mechanical Means
(i)Depth upto 3m" MORTH Specification No.304 (PWD SR2011-12/P.No.
220/27.4)

27.5 kSRRB M2100. 2.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 43.35
approved material complete as per specifications. B. Mechanical Means.
(ii) Depth 3 m to 6 m . Morth specification No. 304 (PWD SR2011-
12/P.No. 220/27.5)

27.6 kSRRB M2100. 2.3. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 53.15
approved material complete as per specifications. B. Mechanical Means.
(iii) Depth above 6 m . Morth specification No. 304 (PWD SR2011-
12/P.No. 220/27.6)
KSRRB M2100 - Excavation on Ordinary Rock with blasting.
27.7 kSRRB M2100. 3.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
Cum 115.25
approved material complete as per specifications. "II. Ordinary rock - (not
requiring blasting) A. Manual Means. Depth above 3 m .
Morth specification No. 304 (PWD SR2011-12/P.No. 220/27.7)

27.8 kSRRB M2100. 3.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
approved material complete as per specifications. "II. Ordinary rock - (not Cum 48.00
requiring blasting) B. Mechanical Means. Depth above 3 m .
Morth specification No. 304 (PWD SR2011-12/P.No. 220/27.8)

KSRRB M2100 - Excavation on Hard Rock with blasting.


27.9 kSRRB M2100. 4.1. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 284.00
approved material complete as per specifications. "III. Hard rock -
(requiring blasting) A. Manual Means. Morth specification No. 304 (PWD
SR2011-12/P.No. 220/27.9)

KSRRB M2100 - Excavation on Hard Rock without blasting.


27.10 kSRRB M2100. 4.2. Earth work in excavation for foundation of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
Cum 300.00
approved material complete as per specifications. "III. Hard rock -
( blasting prohibited) A. Mechanical Means. Morth specification No. 304
(PWD SR2011-12/P.No. 221/27.10)

KSRRB M2100 - Excavation in Marshy Soil


27.11 kSRRB M2100. 5. Excavation in Marshy Soil upto 3m depth for
foundations of structures as per drawing and technical specifications,
including removing the excavated stuff to a lead of 15m, including
dewatering, shoring and shuttering, refilling trenches in 250mm layers,
wherever necessary watering and ramming, including cost of all materials, Cum 384.00
labour complete as per specifications. Morth Chapter -12 (PWD SR2011-
12/P.No. 221/27.11)
27.12 kSRRB M2100.5.1. Earth work in Excavation for foundations of structures
as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 282.00
approved material complete as per specifications. "V. Marshy Soil -
A.Manual means Upto 3 m depth. Morth Specification No. 304. (PWD
SR2011-12/P.No. 221/27.12)

27.13 kSRRB M2100.5.2. Earth work in Excavation for foundations of structures


as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with Cum 79.65
approved material complete as per specifications. "V. Marshy Soil -
A.Mechanical means Upto 3 m depth. Morth Specification No. 304. (PWD
SR2011-12/P.No. 221/27.13)

KSRRB M2100 Filling the foundations

27.14 kSRRB M2100.6. Filling the foundations trenches using approved sand as
per drawing and technical specifications in 250mm layers, Wherever
necessary watering and ramming. including cost of all materials, labour Cum 1599.00
complete as per specifications. "V. Marshy Soil - A.Mechanical means
Upto 3 m depth. Morth Chapter 12 (PWD SR2011-12/P.No. 221/27.14)

KSRRB M2100 Back Filling of abutments using wing wall & Returns

27.15 KSRRB M2100-7. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and Back Filling with approved material Cum 180.00
complete as per specifications. VI. Backfilling in Marshy Foundation Pits."
MORTH Specification No.304. (PWD SR2011-
12/P.No. 221/27.15)

27.16 KSRRB M2100-8. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and Back Filling with approved material
complete as per specifications. VI. Backfilling in Marshy Foundation Pits." Cum 3649.00
MORTH Specification No.304. (PWD SR2011-
12/P.No. 221/27.16) Filling Annular Space Around Footing in Rock
Lean cement concrete 1:3:6 nominal mix

27.17 KSRRB M2100-9. Earth work in excavation for foundation of structures as


per drawing and technical specifications, including setting out, construction
of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and Back Filling with approved material
complete as per specifications. VI. Backfilling in Marshy Foundation Pits." Cum 1436.00
MORTH Specification No.304. (PWD SR2011-
12/P.No. 221/27.17) Sand Filling in foundation Trenches as per
Drawing & Technical Specification No. 304.
KSRRB M2100 PCC 1
27.18 KSRRB M2100-10. Plain cement 1:3:6 nominal mix in foundation with
crushed stone aggregates 40 mm nominal size mechanically mixed,
placed in foundation and compacted by vibration including curing for 14 Cum 3880.00
days complete as per specifications MORTH Specification No. 2100.(PWD
SR2011-12/P.No. 222/27.18)

KSRRB M2100 Brick masonry work


27.19 KSRRB M2100-11. Brick masonry work in Cement Mortar 1:3 in
Foundation complete excluding Pointing and Plastering as per Drawing
and Technical Specifications MORTH Specification No. 1300.(PWD Cum 4052.00
SR2011-12/P.No. 222/27.19)

27.20 KSRRB M2100-11.1. Brick masonry work in Cement Mortar 1:3 in


Foundation complete excluding Pointing and Plastering as per Drawing
and Technical Specifications MORTH Specification No. 1300.(PWD Cum 3988.00
SR2011-12/P.No. 222/27.20) Cement Mortar 1:3 (1 cement : 3 sand)

KSRRB M2100 Stone Masonry Work


27.22 KSRRB M2100-12.1. Stone masonry work in Cement Mortar 1:3 in
Foundation complete as per Drawing and Technical Specifications A.
Square Coursed Rubbil Masonry (first sort) MORTH Specification No. Cum 2656.00
1405.4.(PWD SR2011-12/P.No. 222/27.22)

27.23 KSRRB M2100-12.2. Stone masonry work in Cement Mortar 1:3 in


Foundation complete as per Drawing and Technical Specifications B.
Random Rubbil Masonry (coursed / uncoursed) MORTH Specification No. Cum 2637.00
1405.4.(PWD SR2011-12/P.No. 222/27.23)

KSRRB M2100 Plain / R.C.C in open foundation


27.24 KSRRB M2100-13. Plain / Reinforced Cement Concrete in open
foundation complete as per Drawing and Technical Specifications A. PCC
Grade M-15. MORTH Specification No. 1500, 1700 & 2100.(PWD Cum 3449.00
SR2011-12/P.No. 222/27.24)

27.25 KSRRB M2100-14. Plain / Reinforced Cement Concrete in open


foundation complete as per Drawing and Technical Specifications B. PCC
Grade M-20". MORTH Specification No. 1500, 1700 & 2100.(PWD Cum 4075.00
SR2011-12/P.No. 222/27.25)

27.26 KSRRB M2100-15.1. KSRRB M2100-14. Plain / Reinforced Cement


Concrete M20 with OPC cement @ 320kgs, with 20mm and down size
graded granite metal coarse aggragates @0.69cum and fine aggregates
@0.46cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Cum 4359.00
Reafirmed-2008, in open foundation complete as per Drawing and
Technical Specifications Case- 1 : Using Concrete Mixer" MORTH
Specification No. 1500, 1700 & 2100.(PWD SR2011-12/P.No. 222/27.26)
27.27 KSRRB M2100-15.2. Plain / Reinforced Cement Concrete M20 with OPC
cement @ 320kgs, with 20mm and down size graded granite metal coarse
aggragates @0.69cum and fine aggregates @0.46cum, with
superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-2008, in
open foundation complete as per Drawing and Technical Specifications Cum 4007.00
Case- || : With Baatching plant, Transit Mixer and Concrete pump"
MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-12/P.No.
222/27.27)

27.28 KSRRB M2100-16.1. Plain / Reinforced Cement Concrete design mix


M25 with OPC cement @ 340kgs, with 40mm and down size graded
granite metal coarse aggragates @0.70cum and fine aggregates @0.47
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4455.00
Specifications D. PCC Grade M-25. Case- | : Using concrete mixer "
MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-12/P.No.
223/27.28)

27.29 KSRRB M2100-16.2. Plain / Reinforced Cement Concrete design mix


M25 with OPC cement @ 340kgs, with 40mm and down size graded
granite metal coarse aggragates @0.70cum and fine aggregates @0.47
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4207.00
Specifications Case- || : With Baatching plant, Transit Mixer and Concrete
pump" MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-
12/P.No. 223/27.29)

27.30 KSRRB M2100-17.1. Plain / Reinforced Cement Concrete design mix


M25 with OPC cement @ 340kgs, with 20mm and down size graded
granite metal coarse aggragates @0.70cum and fine aggregates @0.47
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4517.00
Specifications Case- | : Using Concrete mixer" MORTH Specification No.
1500, 1700 & 2100.(PWD SR2011-12/P.No. 223/27.30)

27.31 KSRRB M2100-17.2. Plain / Reinforced Cement Concrete design mix


M25 with OPC cement @ 340kgs, with 20mm and down size graded
granite metal coarse aggragates @0.70cum and fine aggregates @0.47
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4268.00
Specifications Case- || : With Baatching plant, Transit Mixer and Concrete
pump" MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-
12/P.No. 223/27.31)
27.32 KSRRB M2100-18.1. Plain / Reinforced Cement Concrete design mix
M30 with OPC cement @ 360kgs, with 40mm and down size graded
granite metal coarse aggragates @0.69cum and fine aggregates @0.46
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4569.00
Specifications Case- | : Using Concrete mixer " MORTH Specification
No. 1500, 1700 & 2100.(PWD SR2011-12/P.No. 223/27.32)

27.33 KSRRB M2100-18.2. Plain / Reinforced Cement Concrete design mix


M30 with OPC cement @ 360kgs, with 20mm and down size graded
granite metal coarse aggragates @0.69cum and fine aggregates @0.46
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4321.02
Specifications Case- || : With Baatching plant, Transit Mixer and Concrete
pump" MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-
12/P.No. 223/27.33)

27.34 KSRRB M2100-19.1. Plain / Reinforced Cement Concrete design mix


M30 with OPC cement @ 360kgs, with 20mm and down size graded
granite metal coarse aggragates @0.69cum and fine aggregates @0.46
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4628.00
Specifications Case- | : Using Concrete mixer " MORTH Specification
No. 1500, 1700 & 2100.(PWD SR2011-12/P.No. 224/27.34)

27.35 KSRRB M2100-19.2. Plain / Reinforced Cement Concrete design mix


M30 with OPC cement @ 360kgs, with 20mm and down size graded
granite metal coarse aggragates @0.69cum and fine aggregates @0.46
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4381.00
Specifications Case-II: With Batching Plant, Transit Mixer and Concrete
Pump. MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-
12/P.No. 224/27.35)

27.36 KSRRB M2100-20.1. Plain / Reinforced Cement Concrete design mix


M35 with OPC cement @ 390kgs, with 20mm and down size graded
granite metal coarse aggragates @0.68cum and fine aggregates @0.45
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical Cum 4802.00
Specifications Case-I: Using Concrete mixer" MORTH Specification No.
1500, 1700 & 2100.(PWD SR2011-12/P.No. 224/27.36)
27.37 KSRRB M2100-20.2. Plain / Reinforced Cement Concrete design mix
M35 with OPC cement @ 390kgs, with 20mm and down size graded
granite metal coarse aggragates @0.68cum and fine aggregates @0.45
cum, with superplastisiser @ 3lts confirming to IS 9103-1999 Reafirmed-
2008, in open foundation complete as per Drawing and Technical
Specifications. Case-II: With Batching Plant, Transit Mixer and Concrete Cum 4554.00
Pump. MORTH Specification No. 1500, 1700 & 2100.(PWD SR2011-
12/P.No. 224/27.37)
28.00
BRIDGES - OPEN - STRUCTURE
KSRRB M2200- Brick masonry in Substucture
28.1 KSRRB M2200-1 Brick masonry work in 1:3 in sub-structure complete
excluding poinring and plastering, as per drawing and Technical
Specifications complete MORTH Specification No. 1300 & 220 as per cum 9165.00
specifications (PWD SR 2011-12/P.No. 226/28.1)

28.2 KSRRB M2200-2. Pointing with cement mortar (1:3) on brick work in
substucture as per Technical Specifications. Complete as per
Specifications. MORTH Specification No. 1300 & 2200 (PWD SR 2011- Sqm 38.50
12/P.No. 226/28.2)

28.3 KSRRB M2200-3. Plastering with cement mortar (1:3) on brick work in
substucture as per Technical Specifications. Complete as per
Specifications. MORTH Specification No. 1300 & 2200 (PWD SR 2011- Sqm 96.25
12/P.No. 226/28.3)

KSRRB M2200-Stone masonry in Substructure


28.4 KSRRB M2200-4.1. Stone masonry work in cement mortar (1:3) for
substucture complete as per Drawing and Technical Specifications
complete as per specifications. A. Random Rubble Masonry (uncoursed)
cum 2621.00
MORTH Specification No. 1400 & 2200 (PWD SR 2011-12/P.No.
226/28.4)

28.5 KSRRB M2200-4.2. Stone masonry work in cement mortar (1:3) for
substucture complete as per Drawing and Technical Specifications
complete as per specifications. B. Coursed Rubble Masonry (First sort)
MORTH Specification No. 1400 & 2200 (PWD SR 2011-12/P.No. cum 2640.00
226/28.5)

28.6 KSRRB M2200-4.3. Stone masonry work in cement mortar (1:3) for
substucture complete as per Drawing and Technical Specifications
complete as per specifications. C. Ashlar Masonry (First sort) Plain ashlar
cum 3284.00
MORTH Specification No. 1400 & 2200 (PWD SR 2011-12/P.No.
226/28.6)

KSRRB M2200-PCC/RCC
28.7 KSRRB 2200 Plain / Reinforced cement concrete in sub-stucture complete
as per drawing and Technical Specifications complete as per
specifications MORTH Specification No. 1500,1700 & 2200 (PWD SR cum
2011-12/P.No. 226/28.7)

28.7.1 KSRRB M2200-5.1 M15 with OPC cement @240kgs, with 40mm and
down size graded granite metal coarse aggregates @ 0.63cum and fine
aggregates @ 0.42cum a) upto 5mtr height (PWD SR 2011-12/P.No. cum 3647.00
226/28.7.1)
28.7.2 KSRRB M2200-5.2 Design mix M20 with OPC cement @ 300kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.64cum
and fine aggregates @ 0.43cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, b) upto 5mtr height (PWD SR 2011- cum 4310.00
12/P.No. 226/28.7.2)

28.27.3 KSRRB M2200-5.3 Design mix M25 with OPC cement @ 340kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.7cum
and fine aggregates @ 0.47cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, c) - i) upto 5mtr height (PWD SR 2011- cum 4678.00
12/P.No. 226/28.7.3)

28.7.4 KSRRB M2200-5.4 Design mix M25 @ with OPC cement @ 340kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.7cum
and fine aggregates @ 0.47cum, with superplastisiser @ 3 lts confirming
cum 4849.00
to IS9103-1999 Reafirmed-2008, c) - ii) For height above 5 m and upto
10mtr height (PWD SR 2011-12/P.No. 227/28.7.4)

28.7.5 KSRRB M2200-5.5 Design mix M25 @ with OPC cement @ 340kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.7cum
and fine aggregates @ 0.47cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, c) - iii) For height above 10 m. (PWD cum 5061.00
SR 2011-12/P.No. 227/28.7.5)

28.7.6 KSRRB M2200-5.6 Design mix M30 @ with OPC cement @ 360kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, i) upto 5m height. (PWD SR 2011- cum 4800.00
12/P.No. 227/28.7.6)

28.7.7 KSRRB M2200-5.7 Design mix M30 @ with OPC cement @ 360kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3 lts confirming cum 4975.00
to IS9103-1999 Reafirmed-2008, d) PCC Grade M-30 - ii) For height
above 5 m and upto 10m. (PWD SR 2011-12/P.No. 227/28.7.7)

28.7.8 KSRRB M2200-5.8 Design mix M30 @ with OPC cement @ 360kgs, with
40mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, iii) For height above 10 m. (PWD SR cum 5204.00
2011-12/P.No. 227/28.7.8)

28.7.9 KSRRB M2200-5.9 Design mix M20 @ with OPC cement @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, iii) upto 5 m height (PWD SR 2011- cum 4566.00
12/P.No. 227/28.7.9)
28.7.10 KSRRB M2200-5.10 Design mix M20 @ with OPC cement @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3 lts confirming
to IS9103-1999 Reafirmed-2008, ii) For height, upto 10m (PWD SR 2011- cum 4752.00
12/P.No. 227/28.7.10)

28.7.11 KSRRB M2200-5.11 Design mix M20 @ with OPC cement @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @ 0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @ 3 lts confirming
cum 4939.00
to IS9103-1999 Reafirmed-2008, ii) For height above 10m. (PWD SR
2011-12/P.No. 227/28.7.11)

28.7.12 KSRRB M2200-5.12 Design mix with M25 with OPC cement @ 320 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.7
cum and fine aggregates @ 0.47 cum, with superplastisiser @3lts cum 4754.00
confirming to IS9103-1999 Reaffirmed -2008 -i) Upto 5m height (PWD SR
2011-12/P.No. 227/28.7.12)

28.7.13 KSRRB M2200-5.13 Design mix with M25 with OPC cement @ 340 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.7
cum and fine aggregates @ 0.47 cum, with superplastisiser @3lts cum 4910.00
confirming to IS9103-1999 Reaffirmed -2008 -ii) For upto height 10m,
(PWD SR 2011-12/P.No. 228/28.7.13)

28.7.14 KSRRB M2200-5.14 Design mix with M25 with OPC cement @ 340 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.7
cum and fine aggregates @ 0.47 cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed -2008 -iii) For height above 10m, cum 5143.00
(PWD SR 2011-12/P.No. 228/28.7.14)

28.7.15 KSRRB M2200-5.15 Design mix with M30 with OPC cement @ 360 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.69
cum and fine aggregates @ 0.46 cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed -2008 -i) Upto 5m Height (PWD SR cum 4874.00
2011-12/P.No. 228/28.7.15)

28.7.16 KSRRB M2200-5.16 Design mix with M30 with OPC cement @ 360 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.69
cum and fine aggregates @ 0.46 cum, with superplastisiser @3lts
cum 5011.00
confirming to IS9103-1999 Reaffirmed -2008g) RCC Grade M-30 -ii) For
height, upto 10m, (PWD SR 2011-12/P.No. 228/28.7.16)

28.7.17 KSRRB M2200-5.17 Design mix with M30 with OPC cement @ 360 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.69
cum and fine aggregates @ 0.46 cum, with superplastisiser @3lts
cum 5206.00
confirming to IS9103-1999 Reaffirmed -2008 -iii) For height, above 10m,
(PWD SR 2011-12/P.No. 228/28.7.17)
28.7.18 KSRRB M2200-5.18 Design mix with M35 with OPC cement @ 390 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.68
cum and fine aggregates @ 0.45 cum, with superplastisiser @3lts cum 5083.00
confirming to IS9103-1999 Reaffirmed -2008 -iii) For height, above 10m,
(PWD SR 2011-12/P.No. 228/28.7.18)

28.7.19 KSRRB M2200-5.19 Design mix with M35 with OPC cement @ 390 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.68
cum and fine aggregates @ 0.45 cum, with superplastisiser @3lts cum 5197.00
confirming to IS9103-1999 Reaffirmed -2008 -ii) For height, upto 10m,
(PWD SR 2011-12/P.No. 228/28.7.19)

28.7.20 KSRRB M2200-5.20 Design mix with M35 with OPC cement @ 390 kgs,
with 20mm and down size graded granite metal coarse aggregates @ 0.68
cum and fine aggregates @ 0.45 cum, with superplastisiser @3lts
cum 5360.00
confirming to IS9103-1999 Reaffirmed -2008 -iii) For height, above 10m,
(PWD SR 2011-12/P.No. 228/28.7.20)

28.7.21 PCC grade M15 with OPC cement @240 kgs, with 40mm and down size
graded granite metal coarse aggregates @ 0.63 cum and fine aggregates
@ 0.42 cum above 5 mtr height (PWD SR 2011-12/P.No. 228/28.7.21) cum 3767.00

28.7.22 PCC grade design mix M20 with OPC cement @300 kgs, with 40mm and
down size graded granite metal coarse aggregates @ 0.64 cum and fine
aggregates @ 0.43 cum, with superplastisiser @ 3lts confirming to IS9103- cum 4385.00
1999 Reaffirmed-2008, above 5mtr height (PWD SR 2011-12/P.No.
228/28.7.22)

KSRRB M2200-TMT/MS Bar Rein Forcement


28.8 KSRRB M2200-6. Supplying, fitting and placing TMT bar Reinforcement in
sub-structure complete as per drawing and Technical Specifications
complete as per Specifications Morth Specification No. 1600 & 2200 (PWD Tonne 54573.00
SR 2011-12/P.No. 229/28.8)

28.9 KSRRB M2200-7. Supplying, fitting and placing mild steel Reinforcement
complete in sub-structure as per drawing and Technical Specifications
complete as per Specifications Morth Specification No. 1600 & 2200 (PWD Tonne 53597.00
SR 2011-12/P.No. 229/28.9)

KSRRB M2200-Providing weep holes


28.10 KSRRB M2200-Providing weep holes in Brick masonry / Plain/ Reinforced
Concrete aburment, wing wall / return wall with 100 mm dia AC pipe,
extending through the full width of the structure with slope of iv : 20H
towards drawing foce. Complete as per drawing and Technical Nos/mtr 137.25
Specifications Complete as per Specifications. MORTH Specification
No.2706 & 2200 (PWD SR 2011-12/P.No. 229/28.10)
28.11 KSRRB M2200-8.1. Back filling behind abutment, wing wall and return wall
complete as per drawing and Technical Specification complete as per
Specifications. A. Granular material MORTH Specification No. 710.1.4 of cum 255.00
IRC : 78 & 2200. (PWD SR 2011-12/P.No. 229/28.11)

28.12 KSRRB M2200-8.1. Back filling behind abutment, wing wall and return wall
complete as per drawing and Technical Specification complete as per
Specifications. B. Sandy material MORTH Specification No. 710.1.4 of IRC cum 1537.00
: 78 & 2200. (PWD SR 2011-12/P.No. 229/28.12)

KSRRB M2200- Filter Media


28.13 KSRRB M2200-9. Providing and laying of Filter media with granular
materials/stone crushed aggregates satisfying the requirements laid down
in clause 2500.4.2.2 of MORTH Specificatios to a thickness of not less
than 600 mm with smaller size towards the soil and bigger size towards
the wall and provided over the entire surface behind abutment, wing wall
and return wall to the full height compacted to a firm condition complete as Cum 616.00
per drawing and Technical Specification complete as per specifications
MORTH Specification No. 710.1.4 of IRC :78 & 2200 (PWD SR 2011-
12/P.No. 229/28.13)

KSRRB M2200-Bearings
28.14 KSRRB M2200-10. Supplying, fitting and fixing in position true to line and
level cast steel rocker Bearing confirming to IRC: 83(pt-1) Section Ix and
clause 2000.3 of MORTH Specifications coplete including all accessories
as per drawing and Technical Specifications complete as per Tonne 340.00
Specifications MORTH Specifications No. 1000,2000 & 2200 (PWD SR
2011-12/P.No. 229/28.14)

28.15 KSRRB M2200-11. Supplying, fitting and fixing in position true to line and
level forged steel rocker Bearing confirming to IRC: 83(pt-1) Section Ix and
clause 2000.3 of MORTH Specifications coplete including all accessories
as per drawing and Technical Specifications complete as per Tonne 15.80
Specifications MORTH Specifications No. 1000,2000 & 2200 (PWD SR
2011-12/P.No. 229/28.15)

28.16 KSRRB M2200-12. Supplying, fitting and fixing in position true to line and
level sliding plate Bearing with PTFE surface sliding on stainless steel
complete including all accessories as per drawing and technical
Specifications and BS: 5400, section 9.1 & 9.2 (for PTFE) and clause
Tonne 1064.00
2000.4 of MORTH Specifications complete as per Specifications MORTH
Specification No.2000 & 2200 (PWD SR 2011-12/P.No. 229/28.16)

28.17 KSRRB M2200-13. Supplying, fitting and fixing in position true to line and
level alstomeric bearing confirming to IRC :83 (Part-II) section Ix and
clause 2000.5 of MORTH Specifications complete as per Specifications C.C. 0.50
MORTH Specification No.2000 & 2200 (PWD SR 2011-12/P.No.
230/28.17)
28.18 KSRRB M2200-14. Supplying, fitting and fixing in position true to line and
level sliding plate Bearing with Stainless steel plate sliding on stainless
steel plate with mild steel Matrix complete including all accessories as per
drawing and Technical Specifications complete as per Specifications Tonne 1064.00
MORTH Specification No.2000 & 2200 (PWD SR 2011-12/P.No.
230/28.18)

28.19 KSRRB M2200-15. Supplying, fitting and fixing in position true to line and
level POT-PTFE Bearing consisting of a metal piston supported by a disc
or unreinforced elastomer within a meteal cylider, sealing rings, dust seals,
PTFE surface sliding against Stainless steel mating surface, complet
assembly to be of cast steel/ fabricated structural steel, metal and
elastomer elements to be as per IRC :83 part-I & II respectively and other Tonne 341.00
parts confirming BS: 5400, section 9.1 & 9.2 and clause 2000.6 of
MORTH Specifications complete as per Specifications MORTH
Specification No.2000 & 2200 (PWD SR 2011-12/P.No. 230/28.18)
BRIDGES - CONCRETE SUPERSTRUCTURE
KSRRB M2300 - For Solid Slab
29.1 KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 200/29.1)

29.1.1
KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade Cum 4540.00
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. Height upto 5 m (PWD SR2009-10/P.No. 200/29.1.1)

29.1.2
KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade Cum 4730.00
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 200/29.1.2)

29.1.3
KSRRB M2300 - 1.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per specifications. A. RCC Grade Cum 4920.00
M-20. Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700. Height above10 m (PWD SR2009-10/P.No. 200/29.1.3)

KSRRB M2300-For T-beam and Slab


29.2 KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 200/29.2)

29.2.1
KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade Cum 4735.00
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height upto 5 m (PWD SR2009-10/P.No. 200/29.2.1)

29.2.2
KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade Cum 4925.00
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 200/29.2.2)
29.2.3
KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade Cum 5110.00
M-20. Case-I : Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 10 m (PWD SR2009-10/P.No. 200/29.2.3)

KSRRB M2300 - For Solid Slab


29.3 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700.(PWD SR2009-10/P.No.
200/29.3)

29.3.1 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
Cum 4350.00
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height upto 5 m (PWD
SR2009-10/P.No. 200/29.3.1)

29.3.2 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
Cum 4530.00
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height 5 m to 10 m (PWD
SR2009-10/P.No. 200/29.3.2)

29.3.3 KSRRB M2300 - 2.1 Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawin and Technical
Specification M-20 Grade complete as per Specifications A. RCC Grade
Cum 4710.00
M-20. Case-II : Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height above 10 m (PWD
SR2009-10/P.No. 200/29.3.3)

KSRRB M2300- For T-beam and Slab


29.4 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. (PWD SR2009-10/P.No.
200/29.4)

29.4.1 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
Cum 4530.00
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height upto 5 m (PWD
SR2009-10/P.No. 200/29.4.1)
29.4.2 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
Cum 4710.00
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height 5 m to 10 m (PWD
SR2009-10/P.No. 200/29.4.2)

29.4.3 KSRRB M2300- 2.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-20 Grade complete as per Specifications. A. RCC Grade
Cum 4900.00
M-20. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700. Height above 10 m (PWD
SR2009-10/P.No. 200/29.4.3)

KSRRB M2300 - For Solid Slab


29.5 KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 201/29.5)

29.5.1
KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 4960.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 5 m (PWD SR2009-10/P.No. 201/29.5.1)

29.5.2
KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5170.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 201/29.5.2)

29.5.3
KSRRB M2300- 3.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5380.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 10 m (PWD SR2009-10/P.No. 201/29.5.3)

KSRRB M2300-3.2 For T-beam and Slab


29.6 KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. (PWD SR2009-10/P.No. 201/29.6)
29.6.1
KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5170.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height upto 5 m (PWD SR2009-10/P.No. 201/29.6.1)

29.6.2
KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5380.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height 5 m to 10 m (PWD SR2009-10/P.No. 201/29.6.2)

29.6.3
KSRRB M2300- 3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade Cum 5580.00
M-25. Case-I: Using Concrete Mixer MORTH Specification No. 1500,
1600 & 1700. Height above 10 m (PWD SR2009-10/P.No. 201/29.6.2)

KSRRB M2300-For Solid Slab


29.7 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700. (PWD SR2009-10/P.No.
201/29.7)

29.7.1 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 4770.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height upto 5 m (PWD
SR2009-10/P.No. 201/29.7.1)

29.7.2 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 4970.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height 5 m to 10 m(PWD
SR2009-10/P.No. 201/29.7.2)

29.7.3 KSRRB M2300- 4.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 5170.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height above 10 m(PWD
SR2009-10/P.No. 201/29.7.3)

KSRRB M2300-For T-beam and Slab


29.8 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.(PWD SR2009-10/P.No.
201/29.8)

29.8.1 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 4970.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height upto 5m(PWD
SR2009-10/P.No. 201/29.8.1)

29.8.2 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 5170.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700.Height 5m to 10 m(PWD
SR2009-10/P.No. 201/29.8.2)

29.8.3 KSRRB M2300- 4.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-25 Grade complete as per Specifications.B. RCC Grade
Cum 5370.00
M-25. Case-II: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700. Height above 10 m (PWD
SR2009-10/P.No. 201/29.8.3)

KSRRB M2300-FOR SOLID SLAB


29.9 KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 201-202/29.9)

29.9.1
KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5030.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.9.1) Height upto 5m

29.9.2
KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5240.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.9.2) Height 5m to 10m
29.9.3
KSRRB M2300--5.1 Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5450.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.9.3) Height above 10m

KSRRB M2300-For T-beam and Slab


29.10 KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10)

29.10.1
KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5240.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10.1) Height upto 5m

29.10.2
KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5450.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10.2) Height 5m to 10m

29.10.3
KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M- Cum 5660.00
30, Case-1: Using Concrete Mixer MORTH Specification No. 1500, 1600 &
1700 (PWD SR2009-10/P.No. 202/29.10.3) Height above 10m

KSRRB M2300 - For Solid Slab


29.11 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11)

29.11.1 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 4830.00
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11.1) Height upto 5 m
29.11.2 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5030.00
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11.2) Height 5 m 10 m

29.11.3 KSRRB M2300-6.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5230.00
30, Case-1: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.11.3) Height above 10 m

KSRRB M2300- For T-beam and Slab


29.12 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12)

29.12.1 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5030.00
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12.1) Height upto 5m

29.12.2 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5230.00
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12.2) Height 5m to 10m

29.12.3 KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-30 grade complete as per speicifications C. RCC Grade M-
Cum 5430.00
30, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
202/29.12.3) Height above 10m

KSRRB M2300 - For Soild Slab


29.13
KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 202/29.13)
29.13.1 KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5050.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.13.1)
Height upto 5 m

29.13.2 KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5270.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.13.2)
Height 5 m to 10 m

29.13.3 KSRRB M2300-7.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5480.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.13.3)
Height above 10 m

KSRRB M2300- For T-beam and Slab


29.14
KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14)

29.14.1 KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5270.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14.1)
Height upto 5m

29.14.2 KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5480.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14.2)
Height 5m to 10m

29.14.3 KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5700.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.14.3)
Height above 10m

KSRRB M2300- For box girder & balanced cantilever


29.15 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15)

29.15.1 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5910.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15.1)
Height upto 5m

29.15.2 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6340.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15.2)
Height 5m to 10m.

29.15.3 KSRRB M2300-7.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6770.00
Grade M-35, Case-1: Using Concrete Mixer MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 203/29.15.3)
Height above 10m

KSRRB M2300 - For Solid Slab


29.16 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16)

29.16.1 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 4850.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16.1) Height upto 5m

29.16.2 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5060.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16.2) Height 5m to 10m
29.16.3 KSRRB M2300-8.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5270.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.16.3) Height above 10m

KSRRB M2300- For T-beam and Slab


29.17 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 203/29.17)

29.17.1 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5060.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.17.1) Height upto 5m

29.17.2 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5270.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.17.2) Height 5m to 10m

29.17.3 KSRRB M2300-8.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete Cum 5470.00
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.17.3) Height above 10m

KSRRB M2300 - For box girder and balanced cantilever


29.18 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18)

29.18.1 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 5680.00
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18.1) Height upto 5m
29.18.2 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6090.00
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18.2) Height 5m to 10m

29.18.3 KSRRB M2300-8.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-35 grade complete as per speicifications D. RCC /PSC
Cum 6500.00
Grade M-35, Case-11: Using Batching Plant, Transit Mixer & Concrete
Pump. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 204/29.18.2) Height above 10m

KSRRB M2300 - For Solid Slab


29.19 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19)

29.19.1 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5340.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19.1)
Height upto 5m

29.19.2 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5470.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19.2)
Height 5m to 10m

29.19.3 KSRRB M2300-9.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5670.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.19.3)
Height above 10m

KSRRB M2300 - For T-beam and Slab


29.20 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20)
29.20.1 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5470.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20.1)
Height upto 5m

29.20.2 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5670.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20.2)
Height 5m upto 10m

29.20.3 KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
Cum 5860.00
M-40, Case-1: Using Concrete Mixer. MORTH Specification No. 1500,
1600 & 1700 (PWD SR2009-10/P.No. 204/29.20.3)
Height above 10m

KSRRB M2300 - For Solid Slab / Voided Slab


29.21 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump.
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
204/29.21)

29.21.1 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump. Cum 5040.00
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
205/29.21.1) Height upto 5 m

29.21.2 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump. Cum 5240.00
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
205/29.21.2) Height 5 m to 10 m

29.21.3 KSRRB M2300-10.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications E. PCC Grade
M-40, Case-11: Using Batching Plant, Transit Mixer & Concrete Pump. Cum 5440.00
MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-10/P.No.
205/29.21.3) Height above 10 m

KSRRB M2300-For-T-Beam and Slab, including launching of precast


girder by launching truss upto 40m span
29.22 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22)

29.22.1 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5240.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22.1) Height upto 5
m

29.22.2 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5440.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22.2) Height 5 m to
10 m

29.22.3 KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5650.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.22.3) Height above
10 m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.23 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23)

29.23.1 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 5860.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23.1) Height upto 5
m

29.23.2 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 6270.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23.2) Height 5 m to
10 m
29.23.3 KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications Case-11: Using
Cum 6680.00
Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500, 1600 & 1700 (PWD SR2009-10/P.No. 205/29.23.3) Height above
10 m

KSRRB M2300- For Solid Slab/Voided Slab


29.24 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24)

29.24.1 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
Cum 5200.00
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24.1) Height upto 5 m

29.24.2 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
Cum 5420.00
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24.2) Height 5 m to 10 m

29.24.3 KSRRB M2300-11.1. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-40 grade complete as per speicifications. F. PSC Grade
Cum 5630.00
M-40. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.24.3) Height above10 m

KSRRB M2300-For T-beam and Slab, including launching of precast


girder by launching truss upto 40 m span
29.25 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25)

29.25.1 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 5420.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25.1) Height upto 5 m

29.25.2 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 5630.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25.2) Height 5m to 10m
29.25.3 KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 5850.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 205/29.25.3) Height above 10m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.26 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26)

29.26.1 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 6070.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26.1) Height upto 5 m

29.26.2 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 6500.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26.1) Height 5 m to 10 m

29.26.3 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-45 grade complete as per speicifications. F. PSC Grade Cum 6940.00
M-45. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.26.1) Height above 10 m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.27 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27)

29.27.1 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade Cum 6240.00
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27.1) Height upto 5 m

29.27.2 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade Cum 6680.00
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27.2) Height 5 m to 10 m
29.27.3 KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-50 grade complete as per speicifications. G. PSC Grade Cum 7130.00
M-50. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.27.3) Height above 10 m

KSRRB M2300 -For cast-in-situ box girder, segmented


construction and balanced cantilever
29.28 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28)

29.28.1 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade Cum 6560.00
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28.1) Height upto 5 m

29.28.2 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade Cum 7040.00
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28.2) Height 5 m to 10 m

29.28.3 KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed


cement concrete in super-structure as per drawing and Technical
Specification M-55 grade complete as per speicifications. H. PSC Grade Cum 7510.00
M-55. MORTH Specification No. 1500, 1600 & 1700 (PWD SR2009-
10/P.No. 206/29.28.3) Height above 10 m

KSRRB M2300-TMT bar Reinforcement


29.29 KSRRB M2300-14. Supplying, fitting and placing TMT bar reinforcement in
super-structure complete as per drawing and technical Specifications
Complete as per specifications MORTH Specification No. 1600 (PWD Tonne 44180.00
SR2009-10/P.No. 206/29.29)

KSRRB M2300- High tensile wires


29.30 KSRRB M2300-15. High tensile steel wires / strands including all
accessories for stressing, stressing operations and grouting complete as
per drawing and Technical Specificaitons Complete as per specificaitons Tonne 145900.00
MORHT Specificaton No. 1800 (PWD SR2009-10/P.No. 207/29.30)

KSRRB M2300 - Wearing Coat


29.31 KSRRB M2300-16. Providing and laying Cement concrete wearing coat M-
30 grade including reinforcement complete as per drawing and Technical
Specificaitons Complete as per specificaitons MORHT Specificaton No. Cum 7610.00
1800 (PWD SR2009-10/P.No. 207/29.31)
BRIDGES-RIVER TRAINING WORKS AND PROTECTION WORKS
30.1 KSRRBM2500-1.1. Providing and laying boulders apron on river bed for
protection against scour with stone boulders weighing not less than 40 kg
each complete as per drawing and Technical Specification complete as Cum 465.00
per specifications. A. Boulder Laid Dry Without Wire Crates. MORTH
Specification No. 2503. (PWD SR2009-10/P.No. 209/30.1)

30.2 KSRRBM2500-1.2. Providing and laying of boulder apron laid in wire


crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in
100mm x 100mm mesh (weaved diagonally) including 10% extra for laps
and joints laid with stone boulders weighing not less than 40 kg each Cum 1070.00
complete as per drawing and Technical Specification complete as per
specifications. B. Boulder Apron Laid in Wire Crates. MORTH
Specification No. 2503. (PWD SR2009-10/P.No. 209/30.2)

KSRRB M2500-Cement Concrete blocks


30.3 KSRRBM2500-2. Providing and laying of apron with cement concrete
blocks of size 0.5x0.5x0.5 m cast-in-situ and made with nominal mix of M-
15 grade cement concrete with a minimum cement content of 250 kg/cum Cum 3980.00
as per IRC: 21-2000 complete as per specifications. MORTH Specification
No. 2503. (PWD SR2009-10/P.No. 209/30.3)

KSRRB M2500-Pitching
30.4 KSRRBM2500-3. Providing and laying Filter material underneath pitching
in slopes complete as per drawing and Technical specifications. MORTH Cum 930.00
Specification No. 2504. (PWD SR2009-10/P.No. 209/30.4)

30.5 KSRRBM2500-4.1. Providing and laying Pitching on slopes laid over


prepared filter media including boulder apron laid dry in front of toe of
embankment complete as per drawing and Technical specifications. A. Cum 465.00
Stone / Boulder. MORTH Specification No. 2504. (PWD SR2009-
10/P.No. 209/30.5)

30.6 KSRRBM2500-4.2. Providing and laying Pitching on slopes laid over


prepared filter media including boulder apron laid dry in front of toe of
embankment complete as per drawing and Technical specifications. B.
Cum 3980.00
Cement Concrete Blocks of size 0.3x0.3x0.3 m cast in cement
concrete of Grade M-15. MORTH Specification No. 2504. (PWD
SR2009-10/P.No. 209/30.6)

KSRRB M2500-Flooring with Rubble Stone


30.7
KSRRBM2500-5.1. Providing and laying Flooring complete as per drawing
and Technical specifications laid over cement concrete bedding complete
Cum 2390.00
as per specification. A. Rubble stone laid in cement mortat 1:3..
MORTH Specification No. 2505. (PWD SR2009-10/P.No. 209/30.7)
30.8
KSRRBM2500-5.2. Providing and laying Flooring complete as per drawing
and Technical specifications laid over cement concrete bedding complete
Cum 4390.00
as per specification. B. Cement Concrete Blocks Grade M-15".. MORTH
Specification No. 2505. (PWD SR2009-10/P.No. 209/30.8)

30.9 KSRRBM2500-6. Dry rubble flooring Construction of dry rubble flooring


at cross drainage works for relatively less important works complete as per
Cum 630.00
specification. MORTH Specification No. 2506. (PWD SR2009-10/P.No.
209/30.8)

KSRRB M2500- Geotextile filter


30.10 KSRRBM2500-7. Laying of a geotextile filter between pitching and
embankment slopes on which pitching is laid to prevent escapes of the
embankment material through the voids of the stone pitching/cement
concrete blocks as well as to allow free movement of water without Sqm 86.00
creating any uplift head on the pitching complete as per specification.
MORTH Specification No. 700 & 2504. (PWD SR2009-10/P.No.
210/30.10)

KSRRB M2500-Curtain Wall


30.12 KSRRBM2500-9. Curtain Wall complete as per drawing and Technical
specifications. A. Stone masonry in cement mortar (1:3). MORTH Cum 2160.00
Specification No. 2507.2. (PWD SR2009-10/P.No. 210/30.12)

30.13 KSRRBM2500-10. Curtain Wall complete as per drawing and Technical


specifications. B. Cement Concrete Grade M-15. MORTH Specification Cum 3890.00
No. 2507.2. (PWD SR2009-10/P.No. 210/30.13)

KSRRB M2500 - Flexible Apron


30.14 KSRRBM2500-11.Construction of flexible apron 1 m thick comprising of
loose stone boulders weighing not less than 40 kg beyond curtain wall
Cum 495.00
complete as per specifications. MORTH Specification No. 2507.2. (PWD
SR2009-10/P.No. 210/30.14)

KSRRB M2500 - Garbain Structure


30.15
KSRRBM2500-12.Providing and Constructing of a garbain structure for
retaining earth with segments of wire crates of size 7m x 3m x 0.6 m each
divided into 1.5 m compartments by cross netting, made from 4 mm
galvanised steel wire at 32 kg per 10 sqm having minimum tensile strength
of 300 Mpa conforming to IS:280 and galvanizing coating confirming to IS:
Cum 1185.00
4826, woven into mesh with double twist, mesh size not exceeding 100 x
100 mm, filled with boulders with least dimenstion of 200 mm, all loose
ends to be tied with 4 mm galvanised steel wire complete as per
specifications. MORTH Specification No. 2503.3. (PWD SR2009-10/P.No.
210/30.15)
30.16
KSRRBM2500-13. Gabian structure for Erosion Control, River Training
Works and Protection works Providing and Constructing gabian structures
for erosion control, river training works and protection works with wire
crates of size 2m x 1m x 0.3m each divided into 1m compartments by
cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10 Sqm
having minimum tensile strength of 300 Mpa conforming to IS:280 and Cum 2190.00
galvanizing coating conforming to IS:4826, woven into mesh with double
twist, mesh size not exceeding 100 mm x 100 mm, filled with boulders with
least dimension of 200 mm, all loose ends to be securely tied with 4 mm
galvanised steel wire complete as per specifications. MORTH Specification
No. 2503.3. (PWD SR2009-10/P.No. 210/30.16)

EXPANSION JOINTS
KSRRB M2600 - Expansion Joints
31.1 Ksrrb M2600 - 1. Providing and laying a burried expanshion joints,
expanshion gap being 20 mm, covered with 12 mm thick, 200 mm wide
galvanised welded structural steel plate as per IS: 2062, placed
symmetrical to centre line of the joints, resting freely as over the tpo
m 1110.00
surface of the deck concrete, welding of 8 mm dia, 100 mm long
galvanised nails spaced 300 mm c/c along the centre line of the plate, all
as specified in clause 2600.4 MORTH Specification No. 2604 (PWD
SR2009-10/P.No. 212/31.1)

KSRRB M2600 - Filler Joint


31.2 KSRRB M2600-2. i) Providing and fixing 2 mm thick corrugated copper
plate in expasion joint complete as per drawing & Technical Specificaiton
m 1935.00
complete as per specifications. MORTH Specification No. 2605. (PWD
SR2009-10/P.No. 212/31.2)

31.3 KSRRB M2600-3. ii) Providing and fixing 20 mm thick compressible fibre
board in expasion joint complete as per drawing & Technical Specificaiton
m 125.00
complete as per specifications. MORTH Specification No. 2605. (PWD
SR2009-10/P.No. 212/31.3)

31.4 KSRRB M2600-4. iii) Providing and fixing in 20 mm thick premoulded joint
filler in expansion joint for fixed ends of simply supported spans not
exceeding 10m to cater for a horizontal movement upto 20 mm, covered
Smtr 660.00
with sealant complete as per drawing & Technical Specificaiton complete
as per specifications. MORTH Specification No. 2605. (PWD SR2009-
10/P.No. 212/31.4)

31.5 KSRRB M2600-4. iv) Providing and filling joint sealing compound as per
drawings and Technical specifications with coarse sand and 6 per cent
Smtr 45.00
bitumen by weight complete as per specifications. (PWD SR2009-
10/P.No. 212/31.5)

KSRRB M2600 - Asphaltic Plug Joint


31.6
Ksrrb M2600 - 6. Providing and laying of asphaltic plug joint to procide for
horizontal movement of 25 mm and vertical movement of 2 mm, depth of
joint varying from 75 mm to 100 mm, width varying from 500 mm to 750
mm (in traffic direction), covered with a closure plate of 200mm x 6mm of
welded structural steel confirming ti IS: 2062, asphaltic plug to consist of
m 800.00
polymer modified bitumen binder, carefully selected single size aggregate
of 12.5 mm nominal size and a heat resistant foam caulking/backer rod, all
as per approved drawings and specifications, complete as per
specifications, MORTH Specification No. 2600 (PWD SR2009-10/P.No.
213/31.6)

KSRRB M2600 - Elastomeric Slab Seal Expansion Joint


31.7 Ksrrb M2600 - 7. Providing and laying of an elastomeric slab steel
expanstion joints, catering to right or skew (less than 20 deg, moderately
curved with maximum horizontal movement upto 50mm, complete as per
approved drawings and standard specifications to be installed by the
manufacturer/supplier or their authorised representative ensuring m 15140.00
compliance to the manufacturer's instruction for installation and clause
2600.6 of MORTH Specifications for road & bridge work complete as per
specifications. MORTH Specification No. 2606 . (PWD SR2009-10/P.No.
213/31.7)

KSRRB M2600 - Compression Seal Joint


31.8
Ksrrb M2600 - 8. Providing and laying of compression seal joint consisting
of steel armoured nosing at two edges of the joint gap suitably anchored to
the deck concrete and preformed chloroprene elastomer or closed cell
foam joint sealer compressed and fixed into the joint gap special adhesive m 17590.00
binder to cater for a horizontal movement upto 40 mm and vertical
movement of 3 mm complete as per specifications. MORTH Specification.
2600. (PWD SR2009-10/P.No. 213/31.8)

KSRRB M2600 - Strip Seal Expanshion Joint


31.9 Ksrrb M2600 - 9. Providing and laying of a strip seal expanshion joint
catering to maximum horizontal movement upto 70 mm, complete as per
approved drawings and standard specifications to be installed by the
manufacturer/Supplier or their authorised representative ensuring m 14500.00
compliance to the manufacturer's instructions for installation complete as
per specifications. MORTH Specification. 2607. (PWD SR2009-10/P.No.
213/31.9)

KSRRB M2600 - Modular Strip / Box Seal Joint


31.10
Ksrrb M2600 -10. Providing and laying of a modular strip Box seal
expanshion joint including anchorage catering to a horizontal movement
beyond 70 mm and upto 140 mm, complete as per approved drawings and
standard specifications to be installed by the manufacturer/Supplier or their m 6500.00
authorised representative ensuring compliance to the manufacturer's
instructions for installation complete as per specifications. MORTH
Specification. 2600. (PWD SR2009-10/P.No. 213/31.10)
31.11 Ksrrb M2600 -11. Providing and laying of a modular strip Box seal
expanshion joint catering to a horizontal movement beyond 140 mm and
upto 210 mm, complete as per approved drawings and standard
specifications to be installed by the manufacturer/Supplier or their m 7820.00
authorised representative ensuring compliance to the manufacturer's
instructions for installation complete as per specifications. MORTH
Specification. 2600. (PWD SR2009-10/P.No. 213/31.11)
BRIDGES-RIVER TRAINING WORKS AND PROTECTION WORKS
31.0 EXPANSION JOINTS
KSRRB M2600- Expansion Joints
31.1 KSRRB M2600-1. Providing and laying a burried expansion joint,
expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide
galvanished weldable structural steel plate as per IS: 2062, Placed
symmetrical to centre line of the joint, resting freely over the top surface of
the deck concrete, welding of 8 mm dia. 100 mm long galvanished nails m 1114.00
spaced 300 mm c/c along the centre line of the plate, all as specified in
clause 2600.4 MORTH Specification No. 2604 (PWD SR 2011-12/ P.No.
246/31.1)

KSRRBM2600-Filler joint
31.2 KSRRB M2600-2. (i) Providing and fixing 2 mm thick corrugated
copper plate in expansion joint complete as per drawing & Technical
Specification complete as per specifications. MORTH Specification m 2219.00
No. 2605 (PWD SR 2011-12/ P.No. 246/31.2)

31.3 KSRRB M2600-3. (ii) Providing & fixing 20 mm thick compressible fibre
board in expansion joint complete as per drawing & Technical
Specification complete as per specifictions MORTH Specifications m 124.00
No.2605 (PWD SR 2011-12/ P.No. 246/31.3)

31.4 KSRRB M2600-4. (iIi) Providing & fixing in position 20 mm thick


Premoulded joint filler in expansion joint for fixed ends of simply supported
spans not exceeding 10 m to cater for a horizontal movement upto 20 mm,
covered with sealent complete as epr drawing & Technical Specification m 159.00
MORTH Specifications No.2605 (PWD SR 2011-12/ P.No. 246/31.4)

31.5 KSRRB M2600-5 (iv) Providing and filling joint sealing compound as per
drawings and Technical Specifications with coarse sand and 6 per cent
bitumen by weight complete as per specifications MORTH Specification m 16.40
No. 2605 (PWD SR 2011-12/ P.No. 246/31.5)

31.6
BRIDGES - WEARING COAT & APPURTEANCES
KSRRB M2700 - Mastic Asphalt
32.1
KSRRB M2700 -1. Providing and laying 12mm thick mastic asphalt
wearing course on top of deck slab excluding prime coat with paving grade
bitumen meeting the requirements given in table 500-29, prepared by
using mastic cooker and laid to required level and slope after cleaning the
surface, including providing antiskid surface with bitumen precoated fine
grained hard stone chipping of 9.5 mm nominal size at the rate of 0.05 Sqm 221.00
cum per 10 sqm and at an approximate spacing of 10 m center to center in
both directions, pressed into surface when the temperature of surfaces not
less than 100 deg, C, protruding 1 mm to 4 mm over mastic surface, all
complete as per clause 5100.5 complete as per specifications. MORTH
Specification No. 515 & 2702. (PWD SR2011-12/P.No. 250/32.1)

KSRRB M2700 - Railing


32.2 KSRRB M2700 -2. Construction of precast RCC railling of M-30 grade,
aggregates size not exceeding 12 mm, true to line and grade, tolerance of
vertical RCC post not to exceed 1 in 500, centre to concrete spacing
between vertical post not to exceed 2000 mm, leaving adequate space
m 1401.00
between vertical post for expanshion, complete asper approved drawings
and technical specifications complete as per specifications. MORTH
Specification No. 2703, 1500, 1600 & 1700. (PWD SR2011-12/P.No.
250/32.2)

32.3 KSRRB M2700 -3. Construction of RCC railling of M-30 grade, in-situ with
20 mm nominal size aggregate, true to line and grade, tolerance of
vertical RCC post not to exceed 1 in 500, centre to concrete spacing
between vertical post not to exceed 2000 mm, leaving adequate space
m 1374.00
between vertical post for expanshion, complete asper approved drawings
and technical specifications complete as per specifications. MORTH
Specification No. 2703, 1500, 1600 & 1700. (PWD SR2011-12/P.No.
250/32.3)

32.4 KSRRB M2700 -4. Providing, fitting and fixing mild steel railing complete
asper approved drawings and technical specifications complete as per
m 2558.00
specifications. MORTH Specification No. 2703.2, 1900. (PWD SR2011-
12/P.No. 250/32.4)

32.5
KSRRB M2700 -5. Drainage Spouts complete asper approved drawings
and technical specifications complete as per specifications. MORTH No 1126.00
Specification No. 2703.2, 1900. (PWD SR2011-12/P.No. 250/32.5)

KSRRB M2700 - Approach Slab


32.6 KSRRB M2700 -6. PCC M-15 Grade leveling course below approach slab
complete asper approved drawings and technical specifications complete
Cum 3959.00
as per specifications. MORTH Specification No. 2703.2, 1900. (PWD
SR2011-12/P.No. 250/32.6)
32.7 KSRRB M2700 -7. Reinforced cement concrete approach slab grade
M30 including reinforcement and formwork complete asper approved
drawings and technical specifications complete as per specifications. Cum 7416.00
MORTH Specification No. 2703.2, 1900. (PWD SR2011-12/P.No.
250/32.7)

KSRRB M2700 - Precast Pretensioned Girders


32.9
KSRRB M2700 -9. Providing, precasting, transportation and placing in
position precast pretensioned concrete girders as per drawings and
Cum 17988.00
technical specifications complete as per specifications. MORTH
Specification No.1800 & 2300 PWD SR2011-12/P.No. 251/32.9)

32.10 KSRRB M2700 -10. Providing, and fixing Helical pipes in voided
concrete slabs complete as per specifications. MORTH Specification No. m 309.00
1700 & 1800.. (PWD SR2011-12/P.No. 251/32.10)

KSRRB M2700 - Painting on Concrete Surface


32.11 KSRRB M2700 -12. Providing, and applying 2 coats of water based
cement paint to unplastered concrete surface after cleaning the surface of
dirt, dust, oil, grease, efflorescence and applying paint of 1 litre for 2 sqm Sqm 32.40
complete as per specifications. MORTH Specification No. 800.(PWD
SR2011-12/P.No. 251/32.11)
33.00
BRIDGES - REPAIR AND REHABILITATION
33.1 KSRRB M2800-1. Removal of existing cement wearing coat including
its disposal complete as per Technical Specification without causing any
determental effect to any part of the bridge structure and removal of
Sqm 64.10
dismantled with all lifts and lead upto 1000 m complete as per
specifications. MORTH Specification No. 2809.(PWD SR2011-12/P.No.
253/33.1)

33.2 KSRRB M2800-2. Removal of existing asphalt wearing coat comprising


of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt
including its disposal with all lifts and lead upto 1000 m complete as per Sqm 48.20
specifications. MORTH Specification No. 2809.(PWD SR2011-12/P.No.
253/33.2)

33.3 KSRRB M2800-3. Guniting concrete surface with cement mortar


applied with compressor after cleaning surface and spraying with epoxy
Sqm 377.00
complete as per Technical Specification, complete as per specifications.
MORTH Specification No. 2807.(PWD SR2011-12/P.No. 253/33.3)

33.4 KSRRB M2800-4. Providing and inserting nipples with approved fixing
compound after drilling holes for grouting as per Technical specifications
including subsequent cutting/removal and sealing of the holes as
No 65.00
necessary of nipples after completion of grouting with Cement / Epoxy
complete as per specifications. MORTH Specification No. 2800.(PWD
SR2011-12/P.No. 253/33.4)

33.5 KSRRB M2800-5.1. Sealing of cracks/porous concrete by injection


process through nipples/Grouting complete as per Technical Specification
Kgs 167.00
A. Cement Grout" complete as per specifications. MORTH Specification
No. 2800.(PWD SR2011-12/P.No. 253/33.5)

33.6
KSRRB M2800-5.2. Sealing of cracks/porous concrete by injection
process through nipples/Grouting complete as per Technical Specification
Kgs 163.00
A. Cement Mortar (1:1) Grouting" complete as per specifications. MORTH
Specification No. 2806.(PWD SR2011-12/P.No. 253/33.6)

33.7
KSRRB M2800-6.Patching of damaged concrete surface with polymer
concrete and curing complounds, initiator and promoter, available in
present formulations, to be applied as per instructions of manufacturer and Sqm 604.00
as approved by the Engineer complete as per specifications. MORTH
Specification No. 2800.(PWD SR2011-12/P.No. 253/33.7)

33.8 KSRRB M2800-7.Sealing of crack/porous concrete with Epoxy Grout


by injection through nipples complete as per specifications. MORTH Kgs 161.00
Specification No. 2800.(PWD SR2011-12/P.No. 253/33.8)
33.9 KSRRB M2800-8.Applying Epoxy mortar over leached, honey combed
and spalled concrete surface and exposed steel reinforcement complete
Sqm 370.00
as per Technical Specification MORTH Specification No. 2800.(PWD
SR2011-12/P.No. 253/33.9)

33.10
KSRRB M2800-9 Removal of defective concrete, cleaning the surface
throughly, applying the shotcrete mixture mechanically with compressed
air under pressure, comprising of cement, sand, coarse aggregates, water
and quick setting compound in the proportion as per clause 28007.1. sand
and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 Sqm 186.00
respectivelly, water cement ratio ranging from 0.35 to 0.50, density of
gunite not less than 2000 kg/cum, strength not less than 25 Mpa and
workmanship confirming to clause 2800.7.6 complete as per Specifications
MORTH Specification No. 2807.(PWD SR2011-12/P.No. 254/33.10)

33.11 KSRRB M2800-10. Applying pre-packed cement based polymer


mortar of strength 45 Mpa at 28 days for replacement of spalled concrete
Sqm 492.00
complete as per Specifications MORTH Specification No. 2800.(PWD
SR2011-12/P.No. 254/33.11)

33.12 KSRRB M2800-11. Epoxy bonding of new concrete to old concrete


complete as per Specifications MORTH Specification No. 2805.(PWD Sqm 517.00
SR2011-12/P.No. 254/33.12)

33.13
KSRRB M2800-12.1. Providing external prestressing with high tensile
steel wires / strands inclduing drilling for passage of prestressing steel, all
accessories for stressing and stressing operation and grouting complete Tonne 387601.00
asper drawing and technical Specification complete as per Specifications
MORTH Specification No. 2810.(PWD SR2011-12/P.No. 254/33.13)

33.14
KSRRB M2800-12.2. Providing external prestressing with high tensile
steel wires / strands inclduing drilling for passage of prestressing steel, all
accessories for stressing and stressing operation and grouting complete Tonne 292688.00
asper drawing and technical Specification complete as per Specifications
MORTH Specification No. 2810.(PWD SR2011-12/P.No. 254/33.14)

33.15
KSRRB M2800-12.3. Providing external prestressing with high tensile
steel wires / strands inclduing drilling for passage of prestressing steel, all
accessories for stressing and stressing operation and grouting complete Tonne 262500.00
asper drawing and technical Specification complete as per Specifications
MORTH Specification No. 2810.(PWD SR2011-12/P.No. 254/33.15)

33.16 KSRRB M2800-13. Replacement of Bearing complete as per Techniclal


Specifications MORTH Specification No. 2810.(PWD SR2011-12/P.No.
254/33.16)

33.16.1 KSRRB M2800-13. Replacement of Bearing Rocker & Roller complete


as per Techniclal Specifications MORTH Specification No. 2810.(PWD Nos 11639.00
SR2011-12/P.No. 254/33.16.1)
33.16.2 KSRRB M2800-13. Replacement of Bearing Neoprene complete as per
Techniclal Specifications MORTH Specification No. 2810.(PWD SR2011- No 8999.00
12/P.No. 254/33.16.2)

33.18 KSRRB M2800-15. Replacement of Expanshion Joints complete as per


m 2784.00
Techniclal Specifications (PWD SR2011-12/P.No. 254/33.18)

33.19 KSRRB M2800-16. Replacement of Damaged Concrete Railing


complete as per Techniclal Specifications (PWD SR2011-12/P.No. m 134.70
254/33.19)

33.20 KSRRB M2800-17. Replacement of Crash Barrier complete as per


m 250.00
Techniclal Specifications (PWD SR2011-12/P.No. 254/33.20)

33.21 KSRRB M2800-18. Replacement of Damaged Mild steel Railing


complete as per Techniclal Specifications (PWD SR2011-12/P.No. m 111.00
254/33.21)

33.22 KSRRB M2800-19. Repair of Crash Barrier: Repair of concrete crash


barrier with cement concrete M-30 grade by cutting and trimminng the
damaged portion to a regular shape, cleaning the area to be repaired
m 284.00
thoroughly, applying cement concrete after erection of proper form work
complete as per Techniclal Specifications (PWD SR2011-12/P.No.
255/33.22)

33.23 KSRRB M2800-20. Repair of Rcc Railing Carrying out repair of RCC M-
30 railling to bring it to the original shape complete as per Techniclal m 163.00
Specifications (PWD SR2011-12/P.No. 255/33.23)

33.24 KSRRB M2800-21. Repair of Steel Railing to bring it to the original


shape complete as per Techniclal Specifications (PWD SR2011-12/P.No. m 241.00
255/33.24)
34.00 PIPE CULVERTS
KSRRB M2900 - PCC 1:3:6 in Foundation
34.1 KSRRB M2900-1. Plain cement concrete 1:3:6 mix with crushed stone
aggregate 40 m nominal size mechanically mixed, placed in foundation
and compacted by vibration including curing for 14 days complete as per Cum 3243.00
Specifications. MORTH Specification No. 408. (PWD SR2011-12/P.No.
257/34.1)

34.2 KSRRB M2900-2.1. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in single row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 9263.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2011-12/P.No. 257/34.2) A.
1000 mm dia.

34.3 KSRRB M2900-2.2. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in single row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 10165.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2011-12/P.No. 257/34.3) B.
1200 mm dia.

34.4 KSRRB M2900-3.1. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in double row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 18546.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2011-12/P.No. 257/34.4) A.
1000 mm dia.

34.5 KSRRB M2900-3.2. Laying Reinforced cement concrete pipe NP4/


prestressed concrete pipe for culverts on first class bedding of granular
material in double row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 20352.00
works in head walls and parapets complete as per Specifications.
MORTH Specification No. 2900. (PWD SR2011-12/P.No. 257/34.4) B.
1200 mm dia.

34.6 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6)

34.6.1
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1395.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6.1)300 mm dia
34.6.2
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 2441.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6.2)450 mm dia

34.6.3
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3048.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6.3)600 mm dia

34.6.4
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3336.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6.4)750 mm dia

34.6.5
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 5390.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6.5)900 mm dia

34.6.6
Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 8395.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 257/34.6.6)1200 mm dia

34.7 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7)

34.7.1
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 398.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.1)150mm dia
34.7.2
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 534.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.2)250mm dia

34.7.3
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 949.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.3)300mm dia

34.7.4
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1340.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.4)450mm dia

34.7.5
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 1985.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.5)600mm dia

34.7.6
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 2530.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.6)750mm dia

34.7.7
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 3254.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.7)900mm dia

34.7.8
Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2 including
cost of all materials, labour,curing complete as per m 5505.00
Specifications.Specifications No. KSRB 1000,2300. MOST Specification
No.1000/2300. (PWD SR2011-12/P.No. 258/34.7.8)1200mm dia
MAINTENANCE OF ROADS
KSRRB M3000 - Restoration of Rain Cuts
35.1 KSRRB M3000-1 Restoration of rain cuts with soil, moorum, gravel or a
mixture of these, clearing the loose soil, benching for 300 mm width, laying
fresh material in layers not exceeding 250 mm and compacting with plate
m 66.30
compactor or power rammers to restore the original alignment, levels and
slopes complete as per specifications. MORTH Specification No. 3002
(PWD SR 2011-12/P.No. 260/35.1)

KSRRB M3000- Maintenance of Earthen Shoulder


35.2
KSRRB M3000-2. Making up loss of material/irregularation on shoulder to
the design level by adding fresh approved soil and compacting it with
Sqm 14.70
appropriate equipment complete as per specifications. MORTH
Specification No. 3003. (PWD SR 2011-12/P.No. 260/35.2)

35.3 KSRRB M3000-3. Stripping excess soil from the Shoulder surface to
achieve the approved level and compacting with plate compactor complete
Sqm 6.70
as per specifications. MORTH Specification No 3003. (PWD SR 2011-
12/P.No. 260/35.3)

35.4
KSRRB 3000: Filling Pot-holes and Patch Repairs with open graded
Premix surfacing, 20mm. KSRRB M3000-4 : Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per Sqm 118.00
cluase 500.11, compacting, trimming and finishing the surface to form a
smooth continuous suface, all as per clause 3004.2 MORT & H using
80/i00 bituminous (Nominal size) (Bitumen = 0.00146, Metal = 0.027,
Emulsion = 0.00024) (PWD SR 2011-12/P.No. 260/35.4)

KSRRB 3000 Filling pot-holes and patch Repairs with Bituminous


Concrete, 40 mm
35.5
KSRRB 3000: Filling Pot-holes and Patch Repairs with Bituminious
Concrete, 40mm. KSRRB M3000-5 : Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per
Sqm 315.00
cluase 500.4, compacting, trimming and finishing the surface to form a
smooth continuous suface, all as per clause 3004.2 complete as per
Specifications using 80/100 bituminous (Packed) (Bitumen = 0.00459,
Metal = 0.581, Emulsion = 0.00024)MORT & H Specification No. 3004.2
(PWD SR 2011-12/P.No. 260/35.5)

KSRRB M3000 Crack Filling


35.6 KSRRB M3000-6. Filling of crack using slow - curing bitumen emulsion
and applying crusher dust in case crack are wider than 30 mm complete
m 3.10
as per specifications. MORTH Specification No. 3004.3.3 (PWD SR 2011-
12/P.No. 260/35.6)

KSRRB M3000-Dusting
35.7 KSRRB M3000-7. Applying crusher dust to areas of road where bleeding
of excess bitumen has occurred complete as per specifications MORTH m 0.50
Specification No. 3004.4 (PWD SR 2011-12/P.No. 260/35.7)

35.8 KSRRB 3000 Repair of Joint Grooves with Epoxy Mortar.


KSRRB M3000-8. Repair of spalled joint grooves of contraction joints,
longitudinal joints, and expanshion joints in concrete pavements using
m 175.00
epoxy mortar or epoxy concrete complete as per specifications. MORTH
Specification No. 3005.1 (PWD SR 2011-12/P.No. 261/35.8)

KSRRB M3000-Repair of Old Joint Sealant


35.9 KSRRB M3000-9. Removal of existing sealant and re sealing of
contraction,longitudinal or expansion joints in concrete pavement with
m 28.35
fresh sealant material complete as per specifications. MORHT
Specification No. 3005-2 (PWD SR 2011-12/P.No. 261/35.9)

KSRRB M3000- Hill Side Drain Clearance


35.10
KSRRB M3000-10. Removal of earth from the chocked hill side drain and
disposing it on the valley side manually complete as per specificaitons m 23.95
MORTH Specification No 3000. (PWD SR 2011-12/P.No. 261/35.10)

KSRRB M3000- Landside Clearance in Soil


35.11 KSRRB M3000-11. Clearence of land sides in soil and ordinary roack by a
bull-dozer D 80 A-12, 180 HP and disposal of the same on the valley side
Cum 9.80
complete as per specificaitons MORTH Specification No 3000. (PWD SR
2011-12/P.No. 261/35.11)

KSRRB M3000 - Landside Clearance in Hard Rock Requiring Blasting

35.12 KSRRB M3000-12. Clearing and land sides in hard rock requiring blasting
for 50% of the boulders and disposal of the same on the vally side
Cum 46.60
complete as per specifications.MORTH Specification No. 3000. (PWD SR
2011-12/P.No. 261/35.12)

REINFORCED EARTH STRUCTURE


36.1
KSRRB M3100-2. Assembling, joining and laying of reinforcing elements.
A. With reinforcing element of steel / aluminium strips / polymeric strips m 247.00
.MORTH Specification No. 3102. (PWD SR 2011-12/P.No. 263/36.1)

36.2 KSRRB M3100-3. Assembling, joining and laying of reinforcing elements.


B. With reinforcing element of synthetic geogrids. .MORTH Specification Sqm 370.00
No. 3102. (PWD SR 2011-12/P.No. 263/36.2)

36.3 KSRRB M3100-4. Facing Elements of RCC MORTH Specification No.


Sqm 1280.00
3104. (PWD SR 2011-12/P.No. 263/36.3)
OTHER ITEMS
37.1 Providing erecting and removing casurinapole Barricading using poles of
7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at
intervals of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above
ground level, including fixing poles in the ground level for minimum depth
of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete. (PWD SR 2009-
10/P.No. 231/37.1)
37.1.1
Providing erecting and removing casurinapole Barricading using poles of
7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at
intervals of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above
ground level, including fixing poles in the ground level for minimum depth m 42.00
of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete. (PWD SR 2009-
10/P.No. 231/37.1.1) For two tier Barricading

37.1.2 Providing erecting and removing casurinapole Barricading using poles of


7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at
intervals of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above
ground level, including fixing poles in the ground level for minimum depth m 56.00
of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete. (PWD SR 2009-
10/P.No. 231/37.1.2) For three tier Barricading
37.2 Supplying and fixing M.S Rectangular poles made out of 2 equal angles of
65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm
dia M.S hold fast rods each of length 25 cms. Including cost of all materials
cutting, bending scaffolding wherver necessary, nicely finishing the welded
m 475.00
joints with all lead lifts and as per the directions of the Engineer-in-charge
of the work and including providing 2 coats of approved quality paint over
one coat of shop painting (excluding cost of earthwork and concrete)
(PWD SR 2009-10/P.No. 231/37.2)
37.3 Providing chain link fencing 50mm size of 8 guage properly stretched
between rectangular poles and fixed with suitable bolts & nuts, the free
ends shall be welded to the pole and block pipe at top and bottom as
required including cost of all materials, labour, lead and lifts and as per the Sqm 400.00
directions of the Engineer-in-charge of the work etc, complete inncluding
two coats of approved quality paint over one coat of shop paint. (PWD SR
2009-10/P.No. 231/37.3)
37.4
Providing and fixing M.S. Block pipe of 38mm dia, of heavy guage of 14
including removing the bends, cutting the pipe, and fixing pipe in between
the two verticle poles (M.S.rectangular poles) and spot welding the chain
link with M.S. block pipe including cost of all materials wastage in cutting,
m 225.00
and scaffolding wherever necessary with all lead and lift as directed by the
Engineer-in-charge of work etc., complete including two coats of approved
quality paint over one coat of shop paint. (PWD SR 2009-10/P.No.
231/37.4)

37.5 Providing barbed GI wire fencing of 12x12 guage drawn into stone pillars
or iron pillars including drawing in holes wherever necessary excluding the
m 9.30
cost of pillars but including the cost of barbed wire and bending wire etc.,
complete (PWD SR 2009-10/P.No. 231/37.5)
37.6 Providing corrugated cement asbestos Ridge sheets set in C.M 1:3 and
m 325.00
pointed with C.M. 1:3. (PWD SR 2009-10/P.No. 231/37.6)
37.7 Providing Mangalore Ridge tiles set in C.M 1:2 and pointed with C.M 1:2.
m 120.00
(PWD SR 2009-10/P.No. 231/37.7)
37.8 Fixing doors, window and ventilators in walls. (PWD SR 2009-10/P.No.
No 175.00
231/37.8)
37.9 Removing and fixing old Mangalore ridge tiles including pointing with C.M
m 328.00
1:3. (PWD SR 2009-10/P.No. 231/37.9)
37.10 Removing and fixing old Mangalore ridge tiles including pointing with C.M
m 33.00
1:3. (PWD SR 2009-10/P.No. 231/37.10)
37.11 Repairs to roof with available corrugated zinc sheets / A.C sheets with new
J bolts, screws and washes etc., on existing reeper and rafters. (PWD SR Sqm 33.00
2009-10/P.No. 232/37.11)
37.12 Repairing door and window frames with available wood to the required
Sqm 225.00
size. (PWD SR 2009-10/P.No. 232/37.12)
37.13 Repairing and fixing shutters (panelled or glazed) to doors, window
Sqm 225.00
ventilators and cupboards. (PWD SR 2009-10/P.No. 232/37.13)
37.14 Fixing old eve board with necessry screws and approved painting two
m 8.50
coats. (PWD SR 2009-10/P.No. 232/37.14)
37.15
Providing and fixing plain rolled glass 3mm thick with T.W beading of
Sqm 535.00
10mm thick. (PWD SR 2009-10/P.No. 232/37.15)

37.16 Providing and fixing 4mm thick glass panes to steel windows including T.W
beading of 10 mm thick and 2 coats of approved paints. (PWD SR 2009- Sqm 595.00
10/P.No. 232/37.16)
37.17
Easing of shutters of door (PWD SR 2009-10/P.No. 232/37.17) No 28.00

37.18 Easing of window shutters (PWD SR 2009-10/P.No. 232/37.18) No 27.00


37.19 Providing and fixing M.S bars to windows and ventilators including cutting
making holes in frame work with two coats with approved paint etc., Kgs 29.00
complete (PWD SR 2009-10/P.No. 232/37.19)
37.20 Labour charges for fixing iron bars to windows including cutting fixing and
making holes in the frame work and painting two coats with approved paint
Kgs 28.00
etc., complete (excluding the cost of iron bars) (PWD SR 2009-10/P.No.
232/37.20)
37.21 Repairs to cornice or coping or mortar band, 15 cm deep and 8 cm
Sqm 33.00
projection for damaged poriton. (PWD SR 2009-10/P.No. 232/37.21)
37.22 Removing cuddappa slab flooring and stacking the material with a lead of
Sqm 16.00
50 meters. (PWD SR 2009-10/P.No. 232/37.22)
37.23 Removing and resetting Mangalore tiles and replacing broken ones
wherever necessary (excluding cost of new tiles) (PWD SR 2009-10/P.No. Sqm 8.30
232/37.23)
37.24 Cleaning glass with chemicals (PWD SR 2009-10/P.No. 232/37.24) Sqm 5.00
37.25 Removing and refixing existing mortar and pestle stone (PWD SR 2009-
Each 89.00
10/P.No. 232/37.25)
37.26 Removing by chiselling cement joints 50mm to 80mm deep in pipes upto
Sqm 16.00
150mm dia. (PWD SR 2009-10/P.No. 232/37.26)
37.27
Labour charges for fixing plain, frosted or pin headed glass panels (Clear
Sqm 180.00
glass area) with teak wood beading. (PWD SR 2009-10/P.No. 232/37.27)
37.28
Drilling holes of 2.50 cms dia (roof/chejja/stone) (PWD SR 2009-10/P.No.
232/37.28)

37.28.1 Drilling holes of 2.50 cms dia (roof/chejja/stone) (PWD SR 2009-10/P.No.


No 42.00
232/37.28.1) in slabs upto 7.50 cms thick
37.28.2 Drilling holes of 2.50 cms dia (roof/chejja/stone) (PWD SR 2009-10/P.No.
No 51.00
232/37.28.2) in slabs upto 10 cms thick
37.29 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
exposed faces. (PWD SR 2009-10/P.No. 232/37.29)
37.29.1 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
Set 170.00
exposed faces. (PWD SR 2009-10/P.No. 232/37.29.1) 50 cms x 50 cms
x 60 cms
37.29.2 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
Set 135.00
exposed faces. (PWD SR 2009-10/P.No. 232/37.29.2) 40 cms x 40 cms
x 40 cms
37.30
Providing wall black boards in CM 1:3 with two coats of black paint
Sqm 520.00
including finishing etc., complete. (PWD SR 2009-10/P.No. 232/37.30)

37.31 Providing and fixing mortise locks heavy duty to doors. (PWD SR2009-
Each 575.00
10/P.No.233/37.31)
37.32 Providing and fixing hydraulic door closures with mounting heavy duty.
No 960.00
(PWD SR2009-10/P.No.233/37.32)
37.33 Providing and fixing hydraulic door closures Aluminium body (PWD
No 715.00
SR2009-10/P.No.233/37.33)
37.34
Cleaning of glazed tiles (PWD SR2009-10/P.No.233/37.34) Sqm 32.00

37.35 Wall bores in Brick masonry upto 45 cm thick. (PWD SR2009-


Each 52.00
10/P.No.233/37.35)
37.36
Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36)

37.36.1 Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36.1)


Each 112.00
Upto 45 cm thick.
37.36.2 Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36.2)
Each 133.00
Upto 60 to 90 cm thick.
37.36.3 Wall bores in size stone masonry (PWD SR2009-10/P.No.233/37.36.3)
Each 155.00
Upto 90 to 120 cm thick.
37.37 Cutting of road surface for pipeline trenches and disposing of the
excavated stuff as directed including barricading, danger lighting etc., in Cum 133.00
the Macadam road. (PWD SR2009-10/P.No.233/37.37)
37.38 Cutting of road surface for pipeline trenches and disposing of the
excavated stuff as directed including barricading, danger lighting etc., in Cum 210.00
the Asphalt surface road. (PWD SR2009-10/P.No.233/37.38)
37.40 Cutting of road surface for pipeline trenches and disposing of the
excavated stuff as directed including barricading, danger lighting etc., in Cum 410.00
the Cement concrete road. (PWD SR2009-10/P.No.233/37.40)
37.41 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete
(PWD SR2009-10/P.No.233/37.41)
37.41.1 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 205.00
(PWD SR2009-10/P.No.233/37.41.1) 1.50 mtrs depth upto & including
3m depth.
37.41.2 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 375.00
(PWD SR2009-10/P.No.233/37.41.2) beyond 1.50 mtrs depth upto &
including 4.5m depth.
37.41.3 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 580.00
(PWD SR2009-10/P.No.233/37.41.3) beyond 3.00 mtrs depth upto &
including 4.5m depth.
37.41.4 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete Cum 910.00
(PWD SR2009-10/P.No.233/37.41.4) beyond 4.50 mtrs depth upto &
including 6.00m depth.
37.42 Dismantling Mangalore tiles roof and stacking the material within a radius
of 50 metres. (PWD SR2009-10/P.No.233/37.42)

37.42.1 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 27.00
of 50 metres. (PWD SR2009-10/P.No.233/37.42.1) with reepers

37.42.2 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 18.00
of 50 metres. (PWD SR2009-10/P.No.233/37.42.2) without reepers

37.42.3 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 24.00
of 50 metres. (PWD SR2009-10/P.No.233/37.42.2) A.C. sheet roofing.

37.43 Dismantling CI or AC rain water Pipes with fittings and clamps and
stacking the materials with a lead of 50 metres. (PWD SR2009- Sqm 7.00
10/P.No.233/37.43)

37.44 Dismanting weather proof course and removing and conveying the debris
Cum 312.00
to a distance upto 200m (PWD SR2009-10/P.No.234/37.44)

37.45 Dismantling Madras terrace jack arch roof including rafters and stacking
the materials with a lead upto 50m and removing the debries to a distance Sqm 85.00
upto 200m. (PWD SR2009-10/P.No.234/37.45)
37.46 Dismantling stone slab roofing over wooden reepers or RCC barrens
(dismantling reepers and battens to be paid for separately) including
stacking of serviceable materials and disposal of unserviceable within Sqm 100.00
200m lead (with in average thickness of 10 cms(PWD SR2009-
10/P.No.234/37.46)

37.47 Dismanting burnt brick masonry in clay mortar/lime mortar/cement mortar


and stacking the size stone within a radius of 50m and removing the debris Cum 100.00
to a distance upto 200m . (PWD SR2009-10/P.No.234/37.47)

37.48 Dismanting size stone masonry in clay mortar and stacking the size stone
within a radius of 50m and removing the debris to a distance upto 200m . Cum 118.00
(PWD SR2009-10/P.No.234/37.48)

37.49 Dismantling the tile work in floor and roof laid in cement of surki mortar
including stacking the materials with in 50 m lead of tiles thickness 10mm Sqm 17.00
to 25mm. (PWD SR2009-10/P.No.234/37.49)

37.50 Dismantling plastering and removing the debris with a lead upto 200m
Sqm 13.00
(PWD SR2009-10/P.No.234/37.50)

37.51 Dismanting cement concrete flooring or plain cement concrete work


including removing and conveying the debris to a distance upto 200m . Sqm 33.00
(within average thickness of 15 cms) (PWD SR2009-10/P.No.234/37.51)

37.52 Dismantling barbed wire or flexible wirer rope in fencing including making
m 2.75
rolls and stacking within 50m lead. (PWD SR2009-10/P.No.234/37.52)

37.53 Dismantling expanded metal or IRC fabric with weld mesh necessary
battens and beading etc., including stacking the serviceable materials Sqm 10.00
within 50m lead. (PWD SR2009-10/P.No.234/37.53)

37.54 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge


with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two
Sqm 820.00
coats approved paint etc., Complete. (Including cost of screws).(PWD
SR2009-10/P.No.234/37.54)

37.55 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge


with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two
coats approved paint etc., Complete. (Including cost of screws).(PWD Sqm 720.00
SR2009-10/P.No.234/37.55) with weld mesh 75 mm x 25 mm x 6G x
10G.
37.56 Providing and fixing satinless steel hand rails for a height of 900 mm using
m 62.50 mm dia of 16 guage for top measure and verticals at 1.50 m C/c
and 50mm dia of 16 guage stainless steel pipes of 4 rows below top
measures at equal intervels including fiixing with 500 mm dia D.I pipe
m
including cutting, wleding, bending wherever necessary with suitable caps
at top and bottom etc., complete finishing with mat/shininig finishing etc.,
complete as per technical specification and as directed by the Engineer-in-
charge of work. (PWD SR2009-10/P.No.234/37.56)

37.57 Removing and resetting of footpath slab. (PWD SR2009-


Sqm 72.00
10/P.No.234/37.57)

37.58
Removing and resetting of kerb stone(PWD SR2009-10/P.No.234/37.58) m 42.00

37.59 Supplying water storage tanks made of virgin polymer (LLDPE) with two
layers outer Black or Blue and inner White layer of approved quality and
L 6.24
make, confirming to I.S.I./ISO/SSI Specifications.(PWD SR2009-
10/P.No.234/37.59)

37.60 Providing and constructing laterite size stone masonry with stones
chistelled dressing neatly placed in layer not less than 15cm high etc., as
per approved specifications including curing, providing & removing,
scaffolding wherever necessary etc., complete including all lead, lift
loading, unloading etc., for all the materials..(PWD SR2009-
10/P.No.235/37.60)

37.60.1 For Foundation & Basement in CM 1:6 (PWD SR2009-


Cum 2150.00
10/P.No.235/37.60.1)

37.60.2
For Super Structure in CM 1:6 (PWD SR2009-10/P.No.235/37.60.2) Cum 2520.00

37.61 Supplying graded laterite metal with all lead & lift, loading & unloading etc.,
complete. (PWD SR2009-10/P.No.235/37.61)

37.61.1 Supplying graded laterite metal with all lead & lift, loading & unloading etc.,
Cum 350.00
complete. (PWD SR2009-10/P.No.235/37.61.1) 80-150m

37.61.2 Supplying graded laterite metal with all lead & lift, loading & unloading etc.,
Cum 360.00
complete. (PWD SR2009-10/P.No.235/37.61.2) 40-80m

RCC Village Name Board :


37.62
RCC Village Name Board : Supplying and fixing M20 grade RCC Village
name board including excavation in all types of soils. Top edge to be cut to
required shape foundation concrete in CC 1:3:6 with 40mm and down size
metal, plinth concrete in CC 1:2:4 with 20mm and down size metal and
exposed faces of RCC slab and poles enamel painted with two coats
including lattering complete asper detailed specifications, drawings and
direction with RCC poles of size 2.70 x 0.1625 x 0.1625 mtrs 2 nos and
board of size 1.80 x 0.68 mtr complete including providing and fixing bolt Each 9000.00
and nuts of required size for fixing board to the RCC pillars including cost
of all materials lead and lift, loading and unloading and other incidental
charges etc., complete and work is tobe carried out as per approved
design and drawing and as per the standard technical specificationn and
as per the direction of the Engineer-in-charge of the work including
providing and fixing top RCC design board with cornice work of size 1/2 x
1.80 x 0.245 x 0.075 mtr etc complete. (PWD SR2009-10/P.No. 235/37.62)

MS Cautionary Board
37.64
Supplying and fixing cautionary boards of size 90cms x 90cms x 90 cms
triangular shape made of MS Sheet of 15 G (1.60 thick) The board shall be
triangular in shape as per drawing with corner and sides rounded suitably.
The supports shall be MS angle of size ISA 65x65x65x6m. The board is
fixed to one no of MS pole made out of ISA 50x50x6mm with height of
3.65 M with necessary bolts and nuts for fixing the board to the pole
(angle) etc., complete including cost of widening for fixing to the post, cost
of posts, excavation, fixing at specified location to a design depth below
GL in CC of 1:2:4 proportion (minimum section = 1 x 0.30x 0.30x (Below Each 2200.00
GL 0.75+above GL 0.30) with necessary grip rod as shown in the drawing,
including cost of all materials lead and lift, loading & unloading and other
incidental charges etc., complete and work is tobe carried out as per
approved design and drawing and as per the standard technical
specification and as per the direction of the Engineer-in-charge of the work
including providing and fixing top RCC design board with cornice work of
size 1/2 x 1.80 x 0.245 x 0.075 mtr etc complete. (PWD SR2009-
10/P.No.236/37.64)

MS Display board
37.65 Supplying and fixing Display boards of size 1.80 M x 1.60 M made of MS
sheet of 18 G (1.25 mm thick). The board shall be rectangular in shape as
per drawing with corners framed suitable framed with MS angle of size (50
x 50 x6mm all round on four sides at the back side of the board. The board
supports with MS angle of size ISA 75x75x8mm. The board fixed to 2 Nos
of MS pole mase out of ISA 75x75x8mm with a height of 3.80 m with
necessary bolts and nuts for fixing the board to the pole (angle) etc.,
complete including cost of welding for fixing to the post, cost of posts,
excavation, fixing at specified location to a design depth below GL in CC
Each 11300.00
1:2:4 proportion (Min section = 2 x 0.30 x 0.30 x below GL 1.0M) with
necessary grip rod as shown in the drawing including cost of all materials,
labour, lead, lift fabrication welding grinding sharpening, fixing etc., and
including all lead lift loading and unloading all taxes and all incidental
charge etc., complete including painting with 2 coats of enamel paint over
a coat of primer and including lattering as specified by the department etc.,
and the work is tobe carried out as per approved design and drawing and
as per the standard technical specification and as per the direction of the
Engineer-in-charge of the Work. (PWD SR2009-10/P.No.236/37.65)