Présente / Presents:

DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NVFS
NHG RELAYS
Operation condition

NVFS Insulation Resistance


Dielectric Strength
Between contacts
100M

50Hz 500V
min (at 500VDC) Item 7 of IEC255-5

Item 6 of IEC255-5
Between contact and coil 50Hz 750V Item 6 of IEC255-5
Patent No.:99215698.X Shock resistance 147m/s2 11ms IEC68-2-27 Test Ea
32.6 25.2 21 Vibration resistance 10~40Hz double amplitude 1.27mm IEC68-2-6 Test Fc
Terminals strength 8N IEC68-2-21 Test Ua2
Features Solderability 235 2 3 0.5s IEC68-2-20 Test Ta method 1
Small size and light weight. Heavy contact load (30A). Ambient Temperature -40~105
Contact arrangement Form A. Relative Humidity 85% (at 40 ) IEC68-2-3 Test Ca
Suitable for automobile and lamp accessories application. Mass 32g
Insert mounting ,With metal frame. Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.

Ordering Information Dimensions mm /inch


NVFS A 15 DC12V
1 2 3 4
Shrouded type with bracket 19.1
1 Part number NVFS 3 Contact rating 15:15A/14VDC 30:30A/14VDC 0.752
14.9
2 Contact arrangement A:1A 4 Coil rated Voltage(V) DC: 6,12,24 0.587
Fuse-wire 5.2 9
5.1 0.205 0.354
0.201 0.8

6.5
0.256

0.531
0.209
0.031

5.3

13.5
34.6Max.

1.083
24.5

27.5
1.362max.
Contact Data 0.965

1.260
32
Contact Arrangement 1A SPSTNO

0.827
21
Contact Material AgSnO2 6
0.236
Contact Rating (resistive) 15A 30A/14VDC

0.453
1.5
Max. Switching Power 420W

1
Max. Switching Voltage 75VDC Max. Switching Current:30A 4.85 12
Contact Resistance or Voltage drop 50m Item 3.12 of IEC255-7 4-6.3X0.8 0.191 0.472
0.248 0.031 34.6
Operation Electrical 105 Item 3.30 of IEC255-7 1.362
25.2max.
0.992max.
Life Mechanical 107 Item 3.31 of IEC255-7 36max.
1.417max.

Coil Parameter Dimensions


Pickup Release
Coil voltage Coil voltage voltage Coil power Operate Release
Dash VDC VDC(max) VDC(min)
resistance consumption Time Time 86
numbers (65%of rated (20% of rated
10% W ms ms
voltage ) voltage) 4-7 1.2
0.276 0.047
Rated Max.

0.661
86(+)

16.8
30 87
30 87
006-1800 6 7.8 20 3.9 1.2
85
012-1800 12 15.6 80 7.8 2.4 1.8 7 5 Fuse-wise
8.4
024-1800 24 31.2 320 15.6 4.8 0.331
17.9 85
0.705
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
Mounting (Bottom view) Wiring diagram (Bottom view)
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.

NOTES 1).Dimensions are in millimeters.


2).Inch equivalents are given for general information only.

Ningbo Huaguan Relay Corporation LTD.