Pressure Fans

50Hz / 60Hz
Pressure Fans General

Low Noise Pressure Fans Low noise type that meets


the needs of the times

1 Low Noise Design


Performs large-scale fluid analysis of the entire pressure fan, high-performance silent type impeller
shape is optimally designed.

2 Space Saving
Highly reputable low-profile conventional design.
Compatible with replacement demand provided with mounting compatibility with existing products.

3 Long Life
High-grade urea-based grease excellent in water resistance and heat resistance adopted as standard.
Expected design lifetime of 60,000 hrs. (when continuously operated at 50 ℃).
*Only applicable to N series (series code: N).

■Comparison with Existing Model


●Air Volume Comparison (30cm) *At a frequency of 60Hz ●Noise Comparison (30cm)
140 55 55
50Hz Existing model
New model 60Hz Existing model
New model

120 50 50

100 45 45
Static pressure (Pa)

N series
Noise level (dB(A))

Noise level (dB(A))


80 40 40

60 35 35

40 Existing model
30 30

20 25 25

0 20 20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Intake Exhaust Intake Exhaust
Air volume (m3/h)

■Line-Up of Pressure Fans


Standard type Outdoor type Pressure-resistant explosion-proof motor type Stainless steel type
Exhaust Intake Exhaust Intake Exhaust Intake Exhaust
Impeller diameter: 20 to 120cm Impeller diameter: 25 to 120cm Impeller diameter: 20 to 120cm Impeller diameter: 25 to 50cm

All stainless steel type Frameless type Centrifugal contact type


Exhaust Exhaust Exhaust
Impeller diameter: 30 to 40cm Impeller diameter: 30 to 45cm Impeller diameter: 25 to 60cm

■Description of types A model code is assigned to each model of our pressure fans in accordance with the descriptions below. When contacting us, please specify the
model code and the voltage used. (For any information not included in the descriptions below, please contact us.)

PF - 14 B T 2 N
⑦ ① ② ③ ④ ⑤ ⑥ ⑧ Type B (for exhaust only) Type A (for intake only)

①Model type PF: Standard type (different voltage type)/PFS: Stainless steel type/
EPP: Pressure-resistant explosion-proof motor type/WP: Outdoor type/
WPS: All stainless steel type/TP: Frameless type/S: Centrifugal contact type
②Impeller diameter Indicated in inches; For a value in centimeters, multiply the value in inches by 2.5.
③Airflow direction B: Exhaust/A: Intake
* When facing the front of the impeller, exhaust air flows frontward, and intake air flows backward.

④Power supply S: Single-phase/T: Three-phase


⑤Voltage 1: 100 volt class/2: 200 volt class/4: 400 volt class
⑥Series code Ascending alphabetical order
⑦Number of poles None: Standard/Number specified: Multiple-pole type (6: six poles, 8: eight poles)
⑧ID code None, 1, 2...

2
General Pressure Fans

■Handling Precautions
Install the pressure fan at a height of 1.8 meters or more from the floor surface. Use a motor breaker (overload protector) or equivalent as a protection circuit.
Failure to do so may cause injuries or accidents. In the case of installing it at a Choose a motor breaker with around 1.2 times to 1.5 times the allowable current
height of 1.8 meters or less, use the optionally available guard net. level of the specific fan for the purpose of prevention of malfunction.

Make sure that the metallic part of the main unit of the pressure fan does not The diagrams below illustrate connections of power lead wires.
come in direct contact with any building finished with metal lath, wire lath or
Single-phase
metal. Any contact may cause an electric leakage, electric shock or fire.
All models
Make sure to observe the operating ambient temperature and the humidity
White
range. Any excess over the setting range of the specific model may result in Power
Black
supply
burning, deformation or breakage.

For any model equipped with a ground wire, make sure to ground it. Three-phase
Exhaust (standard pressure fans with series code G and later)
Some models come with a drain plug attached to the motor. When such a model
is used outdoors or in a place with high humidity, install it so that the drain plug Intake (pressure fans with voltage specified in their model codes)

is under the motor and remove the lower drain plug before use.
Red
Power White
Install the pressure fan at any sturdy position where no vibration occurs. If the supply Black

position of installation has insufficient strength, the fan may cause resonance
that damages the blade or causes other type of accident. If it is installed at any
Intake (all intake type models other than those specified above)
position that is considered weak, add some reinforcement and install it firmly.

White
Some motors may have built-in thermal protectors so that they will automatically Power Red
be halted in the event of constraint, overload or open-phase operation or if the supply Black

ambient temperature is outside the operating range. In this case, power off the
fan immediately, remedy the cause and wait until the motor cools down before Exhaust (all exhaust type models other than those specified above)
resuming the operation.
White
For installation Power Red
supply Black
For installation of the main unit of the pressure fan and combination with
optional accessories, please refer to the diagram below.

Impeller diameter
20 to 60cm (30) A
Impeller
diameter B C Bolt Impeller
diameter diameterA B C diameter
Bolt

Impeller diameter
75 to 120cm (40) 20cm 220 246 162 M6 50cm 563 620 355 M12
25cm 275 298 165 M6 60cm 664 720 400 M12
Mount the embedded bolt 30cm 325 349 210 M6 75cm 825 900 508 M16
(commercially available).
Outdoor hood 35cm 400 434 250 M10 90cm 980 1040 610 M16
(optional accessory) 40cm 450 485 280 M10 105cm 1132 1207 656 M16
Embedded bolt 45cm 494 540 320 M10 120cm 1345 1425 800 M16
●Install it if the fan (commercially
available) (For any fan with a diameter of 90cm or more, fix it with bolts and nuts at eight positions.)
will be exposed to
rain and wind.
Wall Main unit
Attach the main unit of the pressure fan.
●Fix it with four washers, four spring washers (commercially
available) and then four hexagon nuts (commercially available).

Shutter and fixed louver Washer


●For preventing intrusion of wind and rain, Spring washer
it is recommended to attach a shutter. Hexagon nut

Remove the drain caps (on the


back side of the motor and the bottom
surface) and others.
●Make sure to remove them in a place
with high humidity.

Guard net (optional accessory)


●Make sure to attach it if the fan is installed at a
height of 1.8 meters or less.

3
Pressure Fans Standard Type PF

PF-10BS1D PF-16BS1G 6PF-16BS1G

PF-18BT2A PF-30BT2G

* Please note that the photo shows typical examples and that they may partly differ from actual items.

■Applications
For ventilation, air intake into and air exhaust from factories and warehouses and incorporating into equipment

■Specifications table
Power consumption Allowable current Starting current Noise (dB(A)) Approx.
Impeller Number Nominal Air volume (m3/h)
Airflow Model diameter of poles Power supply output (W) (A) (A) mass
direction (V)
(cm) (P) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
PF-8BS1D Single-phase100 0.6 0.5 1.4 1.4
20 15 552 654 40 40 38 41 3.3
PF-8BS2D Single-phase200 0.3 0.25 0.7 0.7
PF-10BS1D Single-phase100 0.7 0.8 1.4 1.4
25 20 1020 1200 46 49 41 44 3.5
PF-10BS2D Single-phase200 0.35 0.4 0.7 0.7
PF-12BS1N Single-phase100 61 90 0.9 1.2 1.9 2.1
PF-12BS2N 30 Single-phase200 50 1873 2140 61 90 0.5 0.6 0.8 0.7 39.1 42.8 5.4
PF-12BT2N Three-phase200 70 98 0.4 0.5 1.0 0.9
4
PF-14BS1N Single-phase100 145 180 2.3 2.3 5.0 4.7
PF-14BS2N 35 Single-phase200 100 2831 3231 150 191 1.2 1.4 2.8 2.7 43.2 46.0 9.2
PF-14BT2N Three-phase200 132 158 1.0 1.0 2.9 2.7
PF-16BS1G Single-phase100 188 240 3.5 3.45 8.3 7.9
4080 4680
PF-16BS2G Single-phase200 200 200 250 1.8 1.8 4.3 4.2 46 50 11
PF-16BT2G Three-phase200 4022 4543 162 227 1.2 1.2 4.1 3.9
PF-16BT2F 40 Three-phase200 400 4990 5790 300 420 2.3 2.5 8.3 6.3 57 61 12.3
Exhaust type

6PF-16BS1G Single-phase100 86 101 1.4 1.6 2.8 2.6


6PF-16BS2G Single-phase200 100 2880 3340 98 116 0.72 0.84 1.6 1.6 40 44 10.8
6PF-16BT2G Three-phase200 114 118 0.9 0.9 2.2 2.1
PF-18BS1A Single-phase100 230 340 5.5 7.5 11 11
5010 5838 23.5
PF-18BS2A 45 Single-phase200 250 230 340 2.7 3.7 6.5 5.9 54 58
6
PF-18BT2A Three-phase200 5034 5802 210 310 2.3 3.0 6.5 5.7 23
PF-20BS1G Single-phase100 300 450 7.0 7.2 11 11
6200 7020 25
PF-20BS2G 50 Single-phase200 400 300 450 3.5 3.6 6.5 5.9 49 53
PF-20BT2G 6120 7140 270 410 2.6 2.8 6.5 5.7 24.6
PF-24BT2G 750 9420 11160 460 690 4.2 4.2 12 10 51 55.5 33
60
8PF-24BT2G 8 400 7060 8360 250 330 3.0 3.0 5.8 4.6 45 49.5 33
PF-30BT2G 75 Three-phase200 1500 19500 19500 1500 1640 7.7 6.7 33 29 62 64 77.5
6
PF-36BT2G 2200 27000 27000 2050 2250 11.0 11.0 38 34 69 73 86
90
8PF-36BT2 1500 22800 22800 850 1200 6.7 6.2 25 23 71 74 76
8
PF-42BT2G 105 2200 36000 36000 2050 2450 14 12.5 42 35 67 71 118
PF-48B 120 10 3700 42000 42000 3200 3200 20 17 74 63 75 76 153

• The power consumption, air volume and noise figures mentioned above represent the values in the state of Single-phase power supply models
operation under free air conditions. Impeller diameter 35cm or less: Temperature from -30 to +50 ℃, humidity
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method, except for models 90% or less, elevation 1,000m or less
where an impeller diameter ranges from 90cm to 120cm, for which the JIS B 8330-compliant suction pipe method Impeller diameter 40cm with four poles: Temperature from -20 to +50 ℃,
was employed. humidity 90% or less, elevation 1,000m or less
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from Impeller diameter 40cm or more with six poles: Temperature from -10 to
one another. The value in actual operation varies depending on the installation method, the duct form, and so on. +50 ℃, humidity 85% or less, elevation 1,000m or less
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting Three-phase power supply models
a motor breaker. Temperature from -30 to +50 ℃, humidity 85% or less*, elevation 1,000m
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated. or less
• Environment conditions (temperature and humidity) where the fan is installed are as follows. Observe these * For models with the impeller diameter 40cm or less and with four poles,
conditions when using the product. the humidity must be 90% or less.
4
PF Standard Type Pressure Fans

■Specifications table
Impeller Number Nominal Power consumption Allowable current Starting current Noise (dB(A)) Approx.
Airflow Air volume (m3/h)
Model diameter of poles Power supply output (W) (A) (A) mass
direction (V)
(cm) (P) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
PF-8AS1D Single-phase100 0.6 0.5 1.4 1.4
20 15 546 642 40 40 38 42 3.3
PF-8AS2D Single-phase200 0.3 0.25 0.7 0.7
PF-10AS1D Single-phase100 0.7 0.8 1.4 1.4
25 20 1014 1176 46 49 42 46 3.5
PF-10AS2D Single-phase200 0.35 0.4 0.7 0.7
PF-12AS1N Single-phase100 67 96 1.1 1.4 1.9 2.1
1654 1873
PF-12AS2N 30 Single-phase200 50 67 96 0.6 0.6 0.8 0.7 45.6 49.7 5.4
PF-12AT2N 4 Three-phase200 1678 1902 71 102 0.5 0.5 1.0 0.9
PF-14AS1N Single-phase100 146 188 2.2 2.5 5.0 4.7
PF-14AS2N 35 Single-phase200 100 2540 2868 156 197 1.1 1.3 2.8 2.7 48.7 52.3 9.2
PF-14AT2N Three-phase200 136 166 1.1 1.0 2.9 2.7
PF-16AS1D Single-phase100 210 270 3.15 3.4 8.3 7.9
3528 4008
PF-16AS2D Single-phase200 200 204 260 1.7 1.7 4.3 4.2 55 59 10.5
PF-16AT2D Three-phase200 3600 4140 184 263 1.14 1.14 4.1 3.9
Intake type

PF-16AT2F 40 Three-phase200 400 4745 5568 305 460 2.3 2.5 8.3 6.3 57 61 12.3
6PF-16AS1D Single-phase100 90 107 1.5 1.6 2.8 2.6
2442 2832
6PF-16AS2D Single-phase200 100 102 120 0.75 0.75 1.6 1.6 45 49 10.5
6PF-16AT2D Three-phase200 2466 3048 114 123 0.86 0.86 2.2 2.1
PF-18AS1A Single-phase100 250 370 5.8 6.7 11 11
3906 4530 23.5
PF-18AS2A 45 Single-phase200 250 250 370 2.9 3.4 6.5 5.9 56 60
6
PF-18AT2A Three-phase200 3920 4600 230 340 2.3 3.0 6.5 5.7 23
PF-20AS1A Single-phase100 270 400 6.5 6.8 11 11
5280 6120 24.5
PF-20AS2A 50 Single-phase200 400 270 400 3.2 3.4 6.5 5.9 58 61
PF-20AT2A 5220 6000 250 340 2.7 3.0 6.5 5.7 24.3
PF-24AT2G 750 6360 7380 490 710 4.1 4.1 12 10 55.5 59 33
60
8PF-24AT2G 8 400 5420 6280 270 360 3.0 2.8 5.8 4.6 48.5 52 33
PF-30AT2G 75 6 Three-phase200 1500 15000 15000 1380 1600 7.4 7.8 33 29 68 69 81
8PF-36AT2 90 1500 22800 22800 1040 1040 6.4 6.1 25 23 71 74 76
8
PF-42AT2 105 2200 34200 34200 2500 2260 11.4 10.3 42 35 74 76 103
PF-48A 120 10 3700 42000 42000 3200 3200 20 17 74 63 75 76 153
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation Single-phase power supply models
under free air conditions. Impeller diameter 35cm or less: Temperature from -30 to +50 ℃, humidity
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method, except for models where an 90% or less, elevation 1,000m or less
impeller diameter ranges from 90cm to 120cm, for which the JIS B 8330-compliant suction pipe method was employed. Impeller diameter 40cm with four poles: Temperature from -20 to +50 ℃,
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one humidity 90% or less, elevation 1,000m or less
another. The value in actual operation varies depending on the installation method, the duct form, and so on. Impeller diameter 40cm or more with six poles: Temperature from -10 to
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a +50 ℃, humidity 85% or less, elevation 1,000m or less
motor breaker. Three-phase power supply models
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated. Temperature from -30 to +50 ℃, humidity 85% or less*, elevation 1,000m
• Environment conditions (temperature and humidity) where the fan is installed are as follows. Observe these conditions or less
when using the product. * For models with the impeller diameter 40cm or less and with four poles,
the humidity must be 90% or less.
■Special Specifications
Impeller Special order features
Airflow Acid-resistant
diameter direction Different Heat resistance Heat resistance (salt-resistant) Specified MFP
(cm) voltage of 60 ℃ of 80 ℃ color treatment
coating
Exhaust × × × ○ ○ ×
20
Intake × × × ○ ○ ×
Exhaust × × × ○ ○ ×
25
Intake × × × ○ ○ ×
Exhaust *1 × × ○ ○ ×
30
Intake *1 × × ○ ○ ×
Exhaust *1 ○ ○ ○ ○ ○
35
Intake *1 ○ ○ ○ ○ ○
Exhaust *1 *2 *2 ○ ○ *3
40
Intake *1 *2 *2 ○ ○ *3
Exhaust *1 ○ ○ ○ ○ ○
45
Intake *1 ○ ○ ○ ○ ○
Exhaust *1 ○ ○ ○ ○ ○
50
Intake *1 ○ ○ ○ ○ ○
Exhaust ○ ○ ○ ○ ○ ○
60
Intake ○ ○ ○ ○ ○ ○
Exhaust ○ ○ ○ ○ ○ ○
75
Intake ○ ○ ○ ○ ○ ○
Exhaust ○ ○ ○ ○ ○ ○
90
Intake ○ ○ ○ ○ ○ ○
Exhaust ○ ○ ○ ○ ○ ○
105
Intake ○ ○ ○ ○ ○ ○
*1: 400 volt class available for three-phase power supply models only
Exhaust ○ ○ ○ ○ ○ ○
120 *2: Heat resistance feature available for three-phase power supply models only
Intake ○ ○ ○ ○ ○ ○ *3: MFP feature available for three-phase power supply models only
5
Pressure Fans Standard Type PF
■Selection chart
[Exhaust type]
Single-phase, impeller diameter from 20 to 40cm, four poles

50Hz 60Hz
200 200

150 150

Static pressure (Pa)


Static pressure (Pa)

100 100

PFF-16

PFF-16

-16 BS

-16 BS

BS 2G
BS 2G

 50

1G
 50
1G

PF -10B

PF -14
PF -12BS
PF -14
PF -10B

PF
PF -12B

PF

PF
PF
PF

PF

PF-8
PF-8

-10 S2

-14 BS
PF -8BS

-12 2N
-14 BS
-10 S2

-12 S2
PF

BS D

BS 2N
BS
-8B 2D

BS 2N
BS D

BS N

BS1
BS2

1D

1N
1N
1D
S1

1N

1N



Air volume   0 Air volume


  0 0 1000 2000 3000 4000 5000 (m3/h)
0 1000 2000 3000 4000 5000 (m3/h)
(m /min)
3 (m3/min)
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80

Single-phase, impeller diameter from 40 to 50cm, six poles


50Hz 60Hz
150 150
Static pressure (Pa)

100
Static pressure (Pa)

100

6P
PF -18
PF -20

PF -20
6P F-1
PF
PF

PF
-1 BS
PF -18

-2 BS

F- 6B
-20 BS
PF

8B 1

50
0B 1

50 16 S
6P
-1 BS

BS 2G BS 1G
S2 A

6P F-1
8B 1

S2 G

F- 6B 1G
A

2G
S2 A

16 S
BS 2G
A

1G
0 Air volume 0 Air volume
0 1000 2000 3000 4000 5000 6000 7000 8000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 8000 (m3/h)

(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 0 10 20 30 40 50 60 70 80 90 100 110 120 130

Three-phase, impeller diameter from 30 to 40cm, four poles

50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)

100 100
PF
-16
PF

BT
PF

2F
-16
PF

-14
PF

PF

 50  50
PF
PF

BT2
-12

BT
-16

-16
-14
-12

BT

2N


BT

BT
BT
BT

2N
2N
2N

2F
2G

  0 Air volume   0 Air volume


0 1000 2000 3000 4000 5000 6000 (m3/h) 0 1000 2000 3000 4000 5000 6000 (m3/h)

100(m /min) 100 (m /min)


3 3
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90

6
PF Standard Type Pressure Fans

Three-phase, impeller diameter from 40 to 60cm, six poles


50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)

PF
-2
100 100
PF

4
PF

PF

BT
-1

-2

-
8B

24

2
0B

G
BT
T2

T2

2
A

PF
G
G

PF-
6P
50 6P 50

-18
F-
F-

20B
16

16

BT
BT

BT
2G

T2G
2A
2G
0 Air volume 0 Air volume
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

Three-phase, impeller diameter 60cm, eight poles; impeller diameter from 75 to 120cm

300
PF

250
-3
0B
T2
G

200 8P
F-
36
Static pressure (Pa)

BT PF-4
2 2BT2

50Hz 150 PF
-36
BT
2G

100
8P
F-
24

50
PF
BT

-4
2G

8B
0 Air volume
0 5000 10000 15000 20000 25000 30000 35000 40000 45000 (m3/h)
(m3/min)
0 100 200 300 400 500 600 700

300

250

200
PF-
Static pressure (Pa)

8P
30B

F-
36
BT
T

60Hz 150
2G

PF
8P -4
100 8B
F-
PF

24
-36

BT
PF

2G
BT

-4
2G

50
2
BT
2G

0 Air volume
0 5000 10000 15000 20000 25000 30000 35000 40000 45000 (m3/h)
(m3/min)
0 100 200 300 400 500 600 700

7
Pressure Fans Standard Type PF
■Selection chart
[Intake type]
Single-phase, impeller diameter from 20 to 40cm, four poles
50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)


100 100
PF -12
PF
-12 AS

PF -1
AS N

PF

 50
PFF-1

-1 6A

 50
1N

6A S

PFF-14

PF -12

PFF-1

-1 4A
PF -10


PF 0A

PF


PF -8AS2

PF
PF S1D

S12D
4A S

-14 AS

-166AS
-12 AS
PF
PF -8AS
PF

-10 S2
-10 AS2


S12N

-1

AS 2N
-8A D

AS 2D
AS 2N
-8A 2D

AS D
AS D

1D
1N
1N
S1D

1D
1D

  0 Air volume   0 Air volume


0 1000 2000 3000 4000 5000 (m3/h) 0 1000 2000 3000 4000 5000 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80

Single-phase, impeller diameter from 40 to 50cm, six poles


50Hz 60Hz
150 150
PF F-1
P
PFF-18

-1 8A
P

8A S
-1 AS

S2 1A
8A 1
Static pressure (Pa)

Static pressure (Pa)

100 100
A
S2 A
A

P
PF F-20
-2 AS PF F-2
P
0A 2
-2 0A
6P PF-

S1 A
0A S
50
6P PF-

50
6

A
6

F- 16

S2 1A
F- 16

16 AS
16 AS

A
AS 1
AS 1D

2D D
2D

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 6000 7000 8000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 8000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 0 10 20 30 40 50 60 70 80 90 100 110 120 130

Three-phase, impeller diameter from 30 to 40cm, four poles


50Hz 60Hz
300 300

250 250

200 200
Static pressure (Pa)

Static pressure (Pa)

150 150
PF

PF

100 100
-16

-16
AT

AT
2F

PF

2F
PF

-16
PF

PF
PF

 50  50
-1
PF

AT
-14

-14
6A

-12

2D
-12

T2
AT

AT
AT
AT


2N

2N
2N
2N

  0   0
0 1000 2000 3000 4000 5000 6000 Air volume 0 1000 2000 3000 4000 5000 6000Air volume
(m3/h) (m3/h)
0 10 20 30 40 50 60 70 80 90 100 (m /min)
3
0 10 20 30 40 50 60 70 80 90 100 (m3/min)

8
PF Standard Type Pressure Fans

Three-phase, impeller diameter from 40 to 60cm, six poles


50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)


PF
-2
0A
100 100 T2

PF
A

-2
PF

4A
-2

T2
4A

G
PF
PF
6P

T2

-2

6P
-1

50 50
F-1

0A

PF
G
8A

F-
T2

-1
16
6A

T2

8A
AT
A
T2

T2
2D
D

A
0 Air volume 0 Air volume
0 1000 2000 3000 4000 5000 6000 7000 8000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 8000 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 0 10 20 30 40 50 60 70 80 90 100 110 120 130

Three-phase, impeller diameter 60cm, eight poles; impeller diameter from 75 to 120cm

250

200
Static pressure (Pa)

150

50Hz
8P
100 F-
36
8P

AT
PF
F-2

2
PF
-4
4A

PF-

2A

50 -4
8A
T2
T2G

30A
T2G

0 Air volume
0 5000 10000 15000 20000 25000 30000 35000 40000 45000 (m3/h)
(m3/min)
0 100 200 300 400 500 600 700

250

200

8P
F-
36
Static pressure (Pa)

150 AT PF
2 -4
8A
60Hz
8P

100
F-2

PF
PF-
4A

-4
2A
T2

30A

T2
G

50
T2G

0 Air volume
0 5000 10000 15000 20000 25000 30000 35000 40000 45000 (m3/h)
(m3/min)
0 100 200 300 400 500 600 700

9
Pressure Fans Standard Type PF
■Assembly drawing [Exhaust Type]
* For intake type, please contact us.

impeller diameter from 20 to 40cm, four poles

Fig.1 H MAX B Fig.2 H MAX B


C C
F D D
J J F
E E
G G

A A
C
D
E

C
D
E
L L

Fig.3 H MAX B
C
J
F D
E
G

A
C
D
E

* The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Fig. Model A B C D E F G H J L
PF-8BS1D 200 276 246 240 162 4×φ7 8×φ7 147.5 3 Heat-resistant vinyl-insulated wire×2×0.75mm 2×1m
PF-8BS2D 200 276 246 240 162 4×φ7 8×φ7 147.5 3 Heat-resistant vinyl-insulated wire×2×0.75mm2×1m
1
PF-10BS1D 250 327 298 285 165 4×φ7 8×φ7 147.7 3 Heat-resistant vinyl-insulated wire×2×0.75mm2×1m
PF-10BS2D 250 327 298 285 165 4×φ7 8×φ7 147.7 3 Heat-resistant vinyl-insulated wire×2×0.75mm2×1m
PF-12BS1N 300 378 349 330 210 4×φ7 8×φ7 159 3 VCT×2 cores×0.75mm2×1m
PF-12BS2N 300 378 349 330 210 4×φ7 8×φ7 159 3 VCT×2 cores×0.75mm 2×1m
PF-12BT2N 300 378 349 330 210 4×φ7 8×φ7 159 3 VCT×3 cores×0.75mm 2×1m
2
PF-14BS1N 350 467 434 400 250 4×φ12 8×φ12 194 3 VCT×2 cores×0.75mm 2×1m
PF-14BS2N 350 467 434 400 250 4×φ12 8×φ12 194 3 VCT×2 cores×0.75mm 2×1m
PF-14BT2N 350 467 434 400 250 4×φ12 8×φ12 194 3 VCT×3 cores×0.75mm 2×1m
PF-16BS1G 400 518 485 450 280 4×φ12 8×φ12 198 3 VCT×2 cores×0.75mm 2×1m
PF-16BS2G 400 518 485 450 280 4×φ12 8×φ12 198 3 VCT×2 cores×0.75mm 2×1m
3
PF-16BT2G 400 518 485 450 280 4×φ12 8×φ12 198 3 VCT×3 cores×0.75mm 2×1m
PF-16BT2F 400 518 485 450 280 4×φ12 8×φ12 224 3 2PNCT×3 cores×1.25mm 2×1m

10
PF Standard Type Pressure Fans

■Assembly drawing [Exhaust Type]


* For intake type, please contact us.

impeller diameter from 40 to 60cm, six poles

Fig.1 B Fig.2 H MAX B


H MAX C C
D E
J
E

C
D
E
C
D
E

G
L
G
L

* The shape varies slightly depending on the model.


■Dimensions (Unit:mm)
Fig. Model A B C D E F G H J L
6PF-16BS1G 400 518 485 450 280 4×φ12 8×φ12 198 3 VCT×2 cores×0.75mm2×1m
1 6PF-16BS2G 400 518 485 450 280 4×φ12 8×φ12 198 3 VCT×2 cores×0.75mm 2×1m
6PF-16BT2G 400 518 485 450 280 4×φ12 8×φ12 198 3 VCT×3 cores×0.75mm 2×1m
PF-18BS1A 450 570 540 494 320 / 8×φ12 380 / 2PNCT×2 cores×1.25mm 2×1m
PF-18BS2A 450 570 540 494 320 / 8×φ12 380 / 2PNCT×2 cores×1.25mm2×1m
PF-18BT2A 450 570 540 494 320 / 8×φ12 350 / 2PNCT×3 cores×1.25mm2×1m
2 PF-20BS1G 500 659 620 563 355 / 8×φ15 395 / 2PNCT×2 cores×1.25mm2×1m
PF-20BS2G 500 659 620 563 355 / 8×φ15 395 / 2PNCT×2 cores×1.25mm2×1m
PF-20BT2G 500 659 620 563 355 / 8×φ15 365 / 2PNCT×3 cores×1.25mm2×1m
PF-24BT2G 600 760 720 664 400 / 8×φ15 380 / 2PNCT×3 cores×1.25mm2×1m

impeller diameter 60cm, eight poles; impeller diameter from 75 to 120cm

Fig.1 H MAX B Fig.2 B


H MAX C
C
D
I E
I E

A
A
C
D
E

C
E

G
G

L L

Fig.3

* The shape varies slightly depending on the model.


■Dimensions (Unit:mm)
Fig. Model A B C D E F G I L

8PF-24BT2G 600 760 720 664 400 8×φ15 380 75 2PNCT×3 cores×1.25mm2×1m
1
PF-30BT2G 750 955 900 825 508 8×φ20 450 65 2PNCT×3 cores×2mm2×1m
2 PF-36BT2G 900 1110 1040 980 610 8×φ20 440 65 2PNCT×3 cores×2mm 2×1m
3 8PF-36BT2 900 1110 1040 980 610 8×φ20 415 65 2PNCT×3 cores×2mm 2×1m
2 PF-42BT2G 1050 1262 1207 1132 656 8×φ20 560 65 2PNCT×3 cores×3.5mm 2×1m
3 PF-48B 1200 1475 1425 1345 800 8×φ20 540 / 2PNCT×3 cores×5.5mm 2×3m
11
Pressure Fans Standard Type PF
■Special Accessory ■Assembly drawing
525 525
●Intake Attachment 485
442
485
442
280 80 280

Make sure to use it when using the PF-16AT2F (intake type 8×φ12
8×φ12
pressure fan) in combination with a motor-driven shutter.

485

485
280

280
Lead
outlet

Approx. mass 4.5kg

■Example of Combination
TW-16 Shutter and fixed louver
Shutter and fixed louver
Filter unit
Intake attachment Intake attachment
* Please note that the photo shows a typical example and Outdoor hood
(for intake-type powerful silent fans only)
Outdoor hood
(for intake-type powerful silent fans only)
that it may partly differ from the actual item.

Pressure fan Pressure fan

12
WP Outdoor Type Pressure Fans

WP-12B WP-16BT2G WP-16AS1D WP-18BT2A

* Please note that the photo shows a typical example and that it may partly differ from the actual item.

■Applications
For installation in a place with high humidity and outdoors

■Feature
These pressure fans are equipped with outdoor motors suited for conditions of high humidity.

■Notes on Installation
• Any model with the impeller diameter 35cm or more has a drain hole underneath the motor. (For installing the fan with the motor shaft positioned horizontally), make sure that the drain
hole faces downward. When using it outdoors or under conditions of high humidity, remove the drain hole cap facing downward. When using it in any dusty place or when water comes
into the fan, keep the cap attached and detach it occasionally to perform an inspection.
• It is standard to install the fan with the shaft positioned horizontally. If it is installed in a non-standard manner (e.g. at an attitude in which the shaft faces downward), make sure to
specify it at the time of placing an order. Installation of any fan designed to be installed in the standard manner at an attitude in which it faces downward may cause failure.

■Specifications table
Impeller Number Nominal Power consumption Allowable current Starting current Noise (dB(A)) Approx.
Airflow Air volume (m3/h)
Model diameter of poles Power supply output (W) (A) (A) mass
direction (V)
(cm) (P) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
Single-phase100 0.7 0.7 0.9 0.8
WP-10B 25 20 570 690 31 37 45 49 5.5
Single-phase200 0.35 0.35 0.5 0.4
Single-phase100 1.2 1.5 2.8 3
WP-12B 30 50 1446 1704 66 83 51 55 8.5
Single-phase200 0.6 0.75 1.4 1.5
WP-14BS1G Single-phase100 3.2 3 8.3 7.9
4 142 144
WP-14BS2G 35 Single-phase200 100 2660 3150 1.6 1.5 4.3 4.2 43.5 47 9.4
WP-14BT2G Three-phase200 102 122 1.25 1.15 4.1 3.9
WP-16BS1G Single-phase100 188 240 3.5 3.45 8.3 7.9
4080 4680
WP-16BS2G Single-phase200 200 200 250 1.8 1.8 4.3 4.2 46 50 11
WP-16BT2G Three-phase200 4022 4543 162 227 1.2 1.2 4.1 3.9
40
6WP-16BS1G Single-phase100 86 101 1.4 1.6 2.8 2.6
Exhaust type

6WP-16BS2G Single-phase200 100 2880 3340 98 116 0.72 0.84 1.6 1.6 40 44 10.8
6WP-16BT2G Three-phase200 114 118 0.9 0.9 2.2 2.1
WP-18BS1A Single-phase100 5.5 7.5 11 11
5010 5838 230 340 23.5
WP-18BS2A 45 Single-phase200 250 2.7 3.7 6.5 5.9 54 58
6
WP-18BT2A Three-phase200 5034 5802 210 310 2.3 3.0 6.5 5.7 23
WP-20BS1G Single-phase100 7.0 7.2 11 11
6200 7020 300 450 25
WP-20BS2G 50 Single-phase200 400 3.5 3.6 6.5 5.9 49 53
WP-20BT2G 6120 7140 270 410 2.6 2.8 6.5 5.7 24.6
WP-24BT2G 750 9420 11160 460 690 4.2 4.2 12 10 51 55.5
60 33
8WP-24BT2G 8 400 7060 8360 250 330 3.0 3.0 5.8 4.6 45 49.5
WP-30BT2G 75 Three-phase200 1500 19500 19500 1500 1640 7.7 6.7 33 29 62 64 77.5
6
WP-36BT2G 90 27000 27000 2050 2250 11.0 11.0 38 34 69 73 86
2200
WP-42BT2G 105 8 36000 36000 2050 2450 14.0 12.5 42 35 67 71 118
WP-48B 120 10 3700 42000 42000 3200 3200 20 17 74 63 75 76 153
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method, except for models where an impeller diameter ranges from 90cm to 120cm, for which the JIS B
8330-compliant suction pipe method was employed.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation
method, the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• The fan should be installed in an environment where the temperature ranges from -10 ℃ to +40 ℃, the humidity is 100% or less, and the elevation is 1,000m or less. Observe these conditions
when using the product.

13
Pressure Fans Outdoor Type WP

■Specifications table
Impeller Number Power supply Nominal Air volume (m3/h) Power consumption Allowable current Starting current Noise (dB(A)) Approx.
Airflow Model (W) (A) (A)
direction diameter of poles output mass
(V)
(cm) (P) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
Single-phase100 0.7 0.7 0.9 0.8
WP-10A 25 20 402 498 31 37 45 49 5.5
Single-phase200 0.35 0.35 0.5 0.4
Single-phase100 1.2 1.5 2.8 3
WP-12A 30 50 720 840 66 83 51 55 8.5
Single-phase200 0.6 0.75 1.4 1.5
WP-14AS1D Single-phase100 3.0 3.2 8.3 7.9
4 2484 2898 164 186
WP-14AS2D 35 Single-phase200 100 1.6 1.7 4.3 4.2 54 57 9.4
WP-14AT2D Three-phase200 2538 2904 120 160 1.15 1.1 4.1 3.9
WP-16AS1D Single-phase100 210 270 3.15 3.4 8.3 7.9
3528 4008
WP-16AS2D Single-phase200 200 204 260 1.7 1.7 4.3 4.2 55 59 10.5
WP-16AT2D Three-phase200 3600 4140 184 263 1.14 1.14 4.1 3.9
40
6WP-16AS1D Single-phase100 90 107 1.5 1.6 2.8 2.6
2442 2832
6WP-16AS2D Single-phase200 100 102 120 0.75 0.75 1.6 1.6 45 49 10.5
Intake type

6WP-16AT2D Three-phase200 2466 3048 114 123 0.86 0.86 2.2 2.1
WP-18AS1A Single-phase100 5.8 6.7 11 11
3906 4530 250 370 23.5
WP-18AS2A 45 Single-phase200 250 2.9 3.4 6.5 5.9 56 60
6
WP-18AT2A Three-phase200 3920 4600 230 340 2.3 3.0 6.5 5.7 23
WP-20AS1A Single-phase100 6.5 6.8 11 11
5280 6120 270 400 24.5
WP-20AS2A 50 Single-phase200 400 3.2 3.4 6.5 5.9 58 61
WP-20AT2A 5220 6000 250 340 2.7 3.0 6.5 5.7 24.3
WP-24AT2G 750 6360 7380 490 710 4.1 4.1 12 10 55.5 59
60 33
8WP-24AT2G 8 400 5420 6280 270 360 3.0 2.8 5.8 4.6 48.5 52
WP-30AT2G Three-phase200 15000 15000 1380 1600 7.4 7.8 33 29 68 69 81
75 1500
WP-30AT2 6 19500 19500 1580 1400 7.0 6.8 33 29 72 73 73.5
WP-36AT2 90 27000 27000 1720 2200 8.6 9.0 31 28 77 80 76
2200
WP-42AT2 105 8 34200 34200 2500 2260 11.4 10.3 42 35 74 103
76
WP-48A 120 10 3700 42000 42000 3200 3200 20 17 74 63 75 153

• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method, except for models where an impeller diameter ranges from 90cm to 120cm, for which the JIS B
8330-compliant suction pipe method was employed.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation
method, the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• The fan should be installed in an environment where the temperature ranges from -10 ℃ to +40 ℃, the humidity is 100% or less, and the elevation is 1,000m or less. Observe these conditions
when using the product.

■Special Specifications
Impeller Special order features
Airflow Acid-resistant
diameter direction Different Heat resistance Heat resistance (salt-resistant) Specified MFP
(cm) voltage of 50 ℃ of 80 ℃ coating color treatment
Exhaust × × × ○ ○ ○
25
Intake × × × ○ ○ ○
Exhaust × × × ○ ○ ○
30
Intake × × × ○ ○ ○
Exhaust * ○ × ○ ○ ○
35
Intake * ○ × ○ ○ ○
Exhaust * ○ × ○ ○ ○
40
Intake * ○ × ○ ○ ○
Exhaust * ○ × ○ ○ ○
45
Intake * ○ × ○ ○ ○
Exhaust * ○ × ○ ○ ○
50
Intake * ○ × ○ ○ ○
Exhaust ○ ○ × ○ ○ ○
60
Intake ○ ○ × ○ ○ ○
Exhaust ○ ○ × ○ ○ ○
75
Intake ○ ○ × ○ ○ ○
Exhaust ○ ○ × ○ ○ ○
90
Intake ○ ○ × ○ ○ ○
Exhaust ○ ○ × ○ ○ ○
105
Intake ○ ○ × ○ ○ ○
Exhaust ○ ○ × ○ ○ ○
120
Intake ○ ○ × ○ ○ ○
* 400 volt class available for three-phase power supply models only

14
WP Outdoor Type Pressure Fans

■Selection chart
[Exhaust type]
Single-phase, impeller diameter from 25 to 50cm
50Hz 60Hz
150 150

WP
WP -14
-14 BS2
BS G
100 W 100 1G
W P-1
Static pressure (Pa)

Static pressure (Pa)


P- 4B
14 S
BS 2G
1G

W P-20
W P-18
W P-20

W
W
WP -16BS

P-
P-
W

WP
P-

20 BS
6W P-1

18 BS
WP -16B

WP
20 BS
WP

6W

-16
W P-18

BS 1G
BS 1A
50 50
W

P- 6B
BS 1G
P-
-16 S1G

-12

BS2 G

2G
16 S1

2A
18 BS

WP-
2G
6W WP-

BS
WP-

BS G
B
BS 1A
6
P- 16B

1
WP-

G
2G
16 S

10B

2G
2A
BS 1G
12B
10B

2G

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 6000 7000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120

Three-phase, impeller diameter from 35 to 50cm


50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)

W
F-
20
100 W BT 100
P- 2G

W
14

F-
BT

20
WP

2G

BT
6WP
-14

WP-1

W
-16B

2G
P-
T2G
WP

BT

18
W

50 6W 50
P-1
6BT2
2G
P-

BT
-16

6BT
18

2A
2G
BT2

BT

G
2A
G

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 6000 7000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120

Three-phase, impeller diameter from 60 to 120cm


50Hz 60Hz
300 300
WP
-30

250 250
BT
2G

200 200
Static pressure (Pa)

Static pressure (Pa)

WP
-42
BT2

150 150
WP

W
WP-3

P-
WP

48
-24
-24

B
WP
0BT2
BT

W
WP
BT

P-
-42

100
2G

100
WP

48
2G

-36
G

BT

B
-36

8W

BT

2G
8W

BT

P-2

2G
P-2

50 50
2G

4B
4B

T2
T2

G
G

0 Air volume 0 Air volume


0 5000 10000 15000 20000 25000 30000 35000 40000 50000 (m3/h) 0 5000 10000 15000 20000 25000 30000 35000 40000 50000 (m3/h)
(m /min)
3
(m3/min)
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700

15
Pressure Fans Outdoor Type WP
■Selection chart
[Intake type]
Single-phase, impeller diameter from 25 to 50cm
50Hz 60Hz
200 200
WP-1 AS1D

W
WP-1

W P-1
150 150 P- 8
18 AS
4AS2
4

AS 2A
1A

WP-12
Static pressure (Pa)

Static pressure (Pa)


D

WP -14
A
100 100

WP
W
WP-1

W P-2

-14 AS1
P- 0
20 AS

AS D
2A

AS 2A

2D
WP-10
W P-1

1A
W -
P- 8
W

6W P-16A
W
P 16
18 AS

6W
-1 A

W P-2
P

50 50

W P-16
AS 1A

6A S

P -1
P- 0
6W P-

W
P-
20 AS

A
2A
6W

S 1D

16 AS1
2D
P- 16A

AS 2A

6AS 1D

AS D
WP-1

16 S

1A

S
AS 1D

2D
2D
2D
0A

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 6000 (m3/h) 0 1000 2000 3000 4000 5000 6000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Three-phase, impeller diameter from 35 to 50cm


50Hz 60Hz
200 200
W
P-
18

150 150
AT
2A
WP-
Static pressure (Pa)

Static pressure (Pa)


16A

100 100
T2D

W
P-
20
WP

AT
W

2A
-16
P-

W
W
18

P-
AT
P-

20
AT

14

AT
2D

50 50
2A 14A

2A
AT
W

6W
6W

P-

2D
P-
P-

16
16

AT
T2
AT

2D
D
2D

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 6000 (m3/h) 0 1000 2000 3000 4000 5000 6000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Three-phase, impeller diameter from 60 to 120cm


50Hz 60Hz
250 250
WP-3
0AT2

200 200
WP-

G
30
Static pressure (Pa)

Static pressure (Pa)


AT2

150 150
P-
G

48
A
WP-2

WP-2
W
P-

WP

100 100
42

WP-3
W
4AT2

WP
4AT2

-3
8WP
WP-3

P-
8WP

T2

6A
48

-42
W

T2
A

0AT2
-24A
G

G
0AT2

P-

AT
-24A

50 50
36

2
T2G
AT
T2G

0 Air volume 0 Air volume


0 5000 10000 15000 20000 25000 30000 35000 40000 50000 (m3/h) 0 5000 10000 15000 20000 25000 30000 35000 40000 50000 (m3/h)
(m3/min) (m3/min)
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700

16
WP Outdoor Type Pressure Fans

■Assembly drawing [Exhaust Type]


* For intake type, please contact us.

H MAX B
Fig.1 Fig.2 C
D
E

C
D
E
F

L G

H MAX B B
Fig.3 Fig.4
C H MAX
C
E D
E

A
A
C
D
E

D
C

E
G

G L
L

B
Fig.5 C
H MAX
D
E • Any model with the impeller diameter 35cm or more has a drain hole underneath the motor.
G
(For installing the fan with the motor shaft positioned horizontally), make sure that the drain
hole faces downward. When using it outdoors or under conditions of high humidity, remove
the drain hole cap facing downward. When using it in any dusty place or when water comes
A into the fan, keep the cap attached and detach it occasionally to perform an inspection.
• It is standard to install the fan with the shaft positioned horizontally. If it is installed in a
C
E

non-standard manner (e.g. at an attitude in which the shaft faces downward), make sure to
specify it at the time of placing an order. Installation of any fan designed to be installed in
the standard manner at an attitude in which it faces downward may cause failure.

L
* The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Fig. Model A B C D E F G H L
WP-10B 250 327 298 267 165 / 8×φ8.5 215 2PNCT×2 cores×0.75mm2×1m
1
WP-12B 300 378 349 318 210 / 8×φ8.5 255 2PNCT×2 cores×0.75mm 2×1m
WP-14BS1G 350 467 434 400 250 4×φ12 8×φ12 239 2PNCT×2 cores×0.75mm 2×1m
WP-14BS2G 350 467 434 400 250 4×φ12 8×φ12 239 2PNCT×2 cores×0.75mm 2×1m
WP-14BT2G 350 467 434 400 250 4×φ12 8×φ12 197 2PNCT×3 cores×0.75mm 2×1m
WP-16BS1G 400 518 485 450 280 4×φ12 8×φ12 244 2PNCT×2 cores×0.75mm 2×1m
2 WP-16BS2G 400 518 485 450 280 4×φ12 8×φ12 244 2PNCT×2 cores×0.75mm 2×1m
WP-16BT2G 400 518 485 450 280 4×φ12 8×φ12 202 2PNCT×3 cores×0.75mm 2×1m
6WP-16BS1G 400 518 485 450 280 4×φ12 8×φ12 244 2PNCT×2 cores×0.75mm 2×1m
6WP-16BS2G 400 518 485 450 280 4×φ12 8×φ12 244 2PNCT×2 cores×0.75mm 2×1m
6WP-16BT2G 400 518 485 450 280 4×φ12 8×φ12 202 2PNCT×3 cores×0.75mm 2×1m
WP-18BS1A 450 570 540 494 320 / 8×φ12 380 2PNCT×2 cores×1.25mm 2×1m
WP-18BS2A 450 570 540 494 320 / 8×φ12 380 2PNCT×2 cores×1.25mm 2×1m
WP-18BT2A 450 570 540 494 320 / 8×φ12 350 2PNCT×3 cores×1.25mm 2×1m
WP-20BS1G 500 659 620 563 355 / 8×φ15 395 2PNCT×2 cores×1.25mm 2×1m
3
WP-20BS2G 500 659 620 563 355 / 8×φ15 395 2PNCT×2 cores×1.25mm 2×1m
WP-20BT2G 500 659 620 563 355 / 8×φ15 365 2PNCT×3 cores×1.25mm 2×1m
WP-24BT2G 600 760 720 664 400 / 8×φ15 380 2PNCT×3 cores×1.25mm 2×1m
8WP-24BT2G 600 760 720 664 400 / 8×φ15 380 2PNCT×3 cores×1.25mm 2×1m
WP-30BT2G 750 955 900 825 508 / 8×φ20 450 2PNCT×3 cores×2mm 2×1m
4 WP-36BT2G 900 1110 1040 980 610 / 8×φ20 440 2PNCT×3 cores×2mm 2×1m
WP-42BT2G 1050 1262 1207 1132 656 / 8×φ20 560 2PNCT×3 cores×3.5mm 2×1m
5 WP-48B 1200 1475 1425 1345 800 / 8×φ20 540 2PNCT×3 cores×5.5mm 2×3m

17
Pressure Fans Pressure-Resistant Explosion-Proof Motor Type EPP
■Applications
For factories, warehouses and workshops where explosive gas is generated

■Feature
These fans are ideal for ventilation of any space where explosive gas or flammable gas is generated.

■Standard Specifications
●Conforming to the JIS C 0905 and the test requirements formulated by the National Institute of Industrial Safety under
the Ministry of Labour. Applicable under conditions with explosion class 2 or lower and ignitability of G4 or lower.
●Explosion class and ignitability
Ignitability G1 G2 G3 G4 EPP-16B
Explosion Exceeding 450 deg. C Exceeding 300 deg. Exceeding 200 deg. Exceeding 135 deg.
class C and not exceeding 450 deg. C C and not exceeding 300 deg. C C and not exceeding 200 deg. C
●Acetone ●Toluene ●Ethanol ●Gasoline ●Acetaldehyde
●Ammonia ●Propane ●Isopentyl acetate ●Hexane ●Ethyl ether
●Carbon monoxide ●Benzene ●1-Butanol
1 ●Ethane ●Methanol ●Butane
●Acetic acid ●Methane ●Acetic anhydride
●Ethyl acetate
2 ●Coal gas ●Ethylene
<Reference>
Explosion class: Defined in the JIS standards and classified according to the minimum size of the clearance that causes flame propagation in the
explosion test with the standard container into three classes, among which Class 3 is the most dangerous, followed by Class 2 and then by Class 1.
Ignitability: Defined in the JIS standard and classified according to the ignition point into five groups, among which Group 5 (G5) is the highest and G1 is
the lowest.
EPP-36B
●Equipped with a terminal box with a pressure stud
retraction system * Please note that the photo shows typical
examples and that they may partly differ from
Mold terminal actual items.

Terminal box cover

Outlet cap

Connection type Parallel pipe thread


PF¾
Outside diameter: 26.441
conduit tube thread Pitch: 1.81

■Specifications table
*PF1¼ thread for EPP-48B. (Fit for 22mm thick steel conduit tube)

Impeller Number Nominal Power consumption Allowable current Starting current


Airflow Air volume (m3/h) Noise (dB(A)) Approx.
Model diameter of poles Power supply output (W) (A) (A)
mass
direction (cm) (P) (V) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
EPP-8B 20 408 492 28 31 38 42 14.5
Single-phase100 0.7 0.7 0.9 0.81
20
EPP-10B 25 570 690 30 35 45 49 15
Single-phase200 0.35 0.35 0.45 0.41
Single-phase100 1.1 1.1 2.6 2.6
50 45 50
EPP-12B 30 Single-phase200 1020 1200 0.55 1.3 1.1 51 55 21
4 Three-phase200 75 55 60 0.6 0.52 2 1.8
Single-phase100 2.4 2 7.2 6.8
130 130
EPP-14B 35 Single-phase200 100 2820 2760 1.2 1 3.6 3.4 54 61 27
Three-phase200 135 135 0.74 0.61 2.8 2.6
Single-phase100 3.2 3 7.6 7.4
EPP-16B Single-phase200 200 4140 4140 240 260 1.1 1.5 3.8 3.7 60 63
Three-phase200 1.22 1.04 4.7 4.3
37
Exhaust type

40
Single-phase100 1.9 1.8 2.3 2.2
6EPP-16B Single-phase200 100 2880 2880 100 100 0.95 0.9 1.2 1.2 48 54
Three-phase200 0.72 0.64 2 1.8
Single-phase100 5.4 5 15 14
220 220
EPP-18B 45 6 Single-phase200 250 4380 4380 2.2 2 7.5 7 55 56 45
Three-phase200 190 190 1.4 1.3 5 4.5
Single-phase100 7 6 18 16
340 340
EPP-20B 50 Single-phase200 400 6240 6240 3.5 3 9 8 58 60 57
Three-phase200 300 300 2.15 2 7.5 6.8
EPP-24B 6 750 11400 11400 770 750 3.7 3.4 15 13 66 67
60 13
8EPP-24B 8 400 8700 8700 360 400 2.7 2.7 5 4.5 59 59
EPP-30B 75 1500 19500 19500 1600 1600 7.5 6.8 25 21 72 73 95
6 Three-phase200
EPP-36B 90 27600 27600 2000 2400 9.5 8.8 40 35 77 80 140
2200
EPP-42B 105 8 34800 34800 2200 2000 11 10 48 42 74 77 165
EPP-48B 120 10 3700 42000 42000 3200 3200 22 20 86 74 75 76 220
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method, except for models where an impeller diameter ranges from 90cm to 120cm, for which the JIS B
8330-compliant suction pipe method was employed.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation
method, the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• The fan should be installed in an environment where the temperature ranges from -10 ℃ to +40 ℃, the humidity is 85% or less, and the elevation is 1,000m or less. Observe these conditions
when using the product.
18
EPP Pressure-Resistant Explosion-Proof Motor Type Pressure Fans

■Specifications table
Impeller Number Nominal Power consumption Allowable current Starting current
Air volume (m3/h) Noise (dB(A)) Approx.
Airflow Model diameter of poles Power supply output (W) (A) (A) mass
direction (V)
(cm) (P) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
Single-phase100 0.7 0.7 0.9 0.81
EPP-10A 25 20 402 486 35 45 45 49 15
Single-phase200 0.35 0.35 0.45 0.41
EPP-12A 30 Three-phase200 75 720 840 60 65 0.6 0.52 2 1.8 51 55 21
Single-phase100 2.4 2 7.2 6.8
130 130
EPP-14A 35 4 Single-phase200 100 2100 2040 1.2 1 36 3.4 54 61 27
Three-phase200 135 135 0.74 0.61 2.8 2.6
Intake type

Single-phase100 3.2 3 7.6 7.4


3300
EPP-16A Single-phase200 200 3300 240 260 1.7 1.5 3.8 3.7 60 63
Three-phase200 3000 1.22 1.04 4.7 4.3
40 37
Single-phase100 1.9 1.8 2.3 2.2
6EPP-16A Single-phase200 100 2040 2040 100 100 0.95 0.9 1.2 1.2 48 54
6 0.72 0.64 2 1.8
EPP-18A 45 Three-phase200 250 3484 3484 190 190 1.4 1.3 5 4.5 55 56 45
EPP-20A 50 400 4980 4980 300 300 2.15 2 7.5 8.8 58 60 57
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation
method, the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• The fan should be installed in an environment where the temperature ranges from -10 ℃ to +40 ℃, the humidity is 85% or less, and the elevation is 1,000m or less. Observe these conditions
when using the product.

■Special Specifications
Special order features
Impeller Airflow
diameter Different Acid-resistant
Heat resistance Heat resistance (salt-resistant) MFP
direction Specified
(cm) voltage of 60 ℃ of 80 ℃ color treatment
coating
20 Exhaust × × × ○ ○ ×
Exhaust × × × ○ ○ ×
25
Intake × × × ○ ○ ×
Exhaust ○ × × ○ ○ ×
30
Intake ○ × × ○ ○ ×
Exhaust ○ × × ○ ○ ×
35
Intake ○ × × ○ ○ ×
Exhaust ○ × × ○ ○ ×
40
Intake ○ × × ○ ○ ×
Exhaust ○ × × ○ ○ ×
45
Intake ○ × × ○ ○ ×
Exhaust ○ × × ○ ○ ×
50
Intake ○ × × ○ ○ ×
60 Exhaust ○ × × ○ ○ ×
75 Exhaust ○ × × ○ ○ ×
90 Exhaust ○ × × ○ ○ ×
105 Exhaust ○ × × ○ ○ ×
120 Exhaust ○ × × ○ ○ ×

19
Pressure Fans Pressure-Resistant Explosion-Proof Motor Type EPP
■Selection chart
[Exhaust type]
Single-phase, impeller diameter from 20 to 40cm, four poles
50Hz 60Hz

100 100

EPP
EPP
EP

EPP
Static pressure (Pa)

Static pressure (Pa)


EP
EPP

P-1

-14B
-1 2
P-1

-16B
4
-1 2

B
6
B
B

50 50
EPP

EPP
-10B

EPP-1
-8B
EPP

0B
-8B

0 Air volume 0 Air volume


0 1000 2000 3000 4000 (m3/h) 0 1000 2000 3000 4000 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70

Single-phase, impeller diameter from 40 to 50cm, six poles


50Hz 60Hz
300 300

250 250
EP

EP
P-

P-
20

200 20 200
B

B
Static pressure (Pa)

Static pressure (Pa)

150 150
EP
P-
18

EP
B

P-

100 100
18
6E

B
6E
PP

PP
-16

50 50
-16
B

0 Air volume 0 Air volume


0 2500 5000 (m3/h) 0 2500 5000 (m3/h)
(m /min)
3
(m3/min)
0 100 0 100

Three-phase, impeller diameter from 30 to 40cm, four poles


50Hz 60Hz
150 150

100 100
Static pressure (Pa)

Static pressure (Pa)

EPP
EPP
EP

EPP

EP

-16B
P-1

P-1

-14B
-16
4

2B
B

50 50
EP
P-1
2B

Air volume Air volume


0 0
0 1000 2000 3000 4000 (m3/h) 0 1000 2000 3000 4000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70

20
EPP Pressure-Resistant Explosion-Proof Motor Type Pressure Fans

■Selection chart
[Exhaust type]
Three-phase, impeller diameter 40cm, six poles / eight poles; from 45 to 120cm
50Hz 60Hz
200 200

EPP-1
150 150
EPP-1

8 EP
Static pressure (Pa)

Static pressure (Pa)

8B
8EP

P-2 4
8B

EP
P-24

EP
100 100

EP
P-4
P-

B
48

P-4
B

2
EP

B
B

EPP-24

8
P-4

B
EP
EPP-3
EP
EPP-

EPP-3

P-3
50 50
6EPP-1

2B
P-

6EPP-16B
36

EPP-20B
EPP-20

6B
B
24B

0B
0B
6B

0 Air volume 0 Air volume


B

0 5000 10000 15000 20000 25000 30000 35000 40000 (m3/h) 0 5000 10000 15000 20000 25000 30000 35000 40000 (m3/h)
(m3/min) (m3/min)
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700

[Intake type]
Single-phase, impeller diameter from 25 to 40cm, four poles
50Hz 60Hz

EPP-1
EPP

100 100
Static pressure (Pa)

Static pressure (Pa)


-14

4A

EPP-1
EPP

EPP-1
A

-16

6A
0A
A

50 50
EPP-10
A

0 Air volume 0 Air volume


0 1000 2000 3000 (m3/h) 0 1000 2000 3000 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 0 10 20 30 40 50

Single-phase, impeller diameter 40cm, six poles


50Hz 60Hz
150 150
Static pressure (Pa)

Static pressure (Pa)

100 100

6E
6E

PP
PP

50 50
-1
-1

6A
6
A

0 Air volume 0 Air volume


0 1000 2000 2500 (m3/h) 0 1000 2000 2500 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 0 10 20 30 40

Three-phase, impeller diameter from 30 to 40cm, four poles


50Hz 60Hz

150 150
Static pressure (Pa)

Static pressure (Pa)

100 100
EP
EPP
EP

P-1

EPP
P

-12A

4
-16
EPP

A
EP

-16A
A
P
-12A

50 50
-14
A

Air volume Air volume


0 0
0 1000 2000 3000 (m3/h) 0 1000 2000 3000 (m3/h)

0 10 20 30 40 50
(m /min) 3

0 10 20 30 40 50
(m3/min) 21
Pressure Fans Pressure-Resistant Explosion-Proof Motor Type EPP
■Selection chart
[Intake type]
Three-phase, impeller diameter from 40 to 50cm, six poles
50Hz 60Hz
200 200

150 150

EP

EP
EP
Static pressure (Pa)

Static pressure (Pa)

P-1

P-2
P-
20

0
A
A
EP

A
100 100
P-1
8A

6EP
6E

P-1
P

50 50
P-1

6A(
6A(

6P)
6P

Air volume Air volume


0 0
0 1000 2000 3000 4000 5000 6000 7000 7500 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 7500 (m3/h)
(m3/min) (m3/min)
0 50 100 0 50 100

■Assembly drawing [Exhaust Type]


* For intake type, please contact us.

H B
Fig.1 Fig.2
H B C

C D

G 400
D

G 210


600
) (φ
300
(φ
720
349

E
E

L L

■Dimensions (Unit:mm)
Fig. Model A B C D E G H L
EPP-8B 200 276 246 220 162 8×φ7 310 PF¾ thread
1 EPP-10B 250 327 298 267 165 8×φ8.5 315 PF¾ thread
EPP-12B 300 378 349 322 210 8×φ7 325 PF¾ thread
EPP-14B 350 467 434 391 250 8×φ12 355 PF¾ thread
EPP-16B 400 518 485 442 280 8×φ12 365 PF¾ thread
6EPP-16B 400 518 485 442 280 8×φ12 365 PF¾ thread
EPP-18B 450 570 540 494 320 8×φ12 425 PF¾ thread
EPP-20B 500 659 620 563 355 8×φ15 445 PF¾ thread
2 EPP-24B 600 760 720 664 400 8×φ15 490 PF¾ thread
8EPP-24B 600 760 720 664 400 8×φ15 490 PF¾ thread
EPP-30B 750 955 900 825 508 8×φ20 510 PF¾ thread
EPP-36B 900 1110 1040 980 610 8×φ20 475 PF¾ thread
EPP-42B 1050 1262 1207 1132 656 8×φ20 495 PF¾ thread
EPP-48B 1200 1475 1425 1345 800 8×φ20 600 PF1¼ thread

22
PFS Stainless Steel Type Pressure Fans

■Applications
For kitchens, coastal areas, food factories, and other places
where rust prevention is required

PFS-12BT2N
* Please note that the photo shows typical examples

■Specifications table and that they may partly differ from actual items.

Power consumption Allowable current Starting current


Impeller Number Power Nominal Air volume (m3/h) (W) (A) (A) Noise (dB(A)) Approx.
Airflow diameter of poles supply output mass
direction Model
(cm) (P) (V) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)

PFS-10BSD 25 20 1020 1200 43 48 0.7 0.8 1.2 1.1 41 44 3.5


Single-phase100
PFS-12BS1N 61 90 0.9 1.2 1.9 2.1

PFS-12BS2N 30 Single-phase200 50 1873 2140 61 90 0.5 0.6 0.8 0.7 39.1 42.8 5.4
Exhaust type

PFS-12BT2N 4 Three-phase200 70 98 0.4 0.5 1.0 0.9

PFS-16BS1D Single-phase100 165 210 3.5 3.45 8.3 7.9


3678 4272
PFS-16BS2D 40 Single-phase200 200 180 210/230 1.8 1.8 4.3 4.2/4.6 51 55 10.7

PFS-16BT2D 3762 4392 150 200 1.2 1.2 4.1 3.9


Three-phase200
PFS-20BT2A 50 6 400 6360 7440 260 380 2.5 3.2 6.5 5.7 53 57 24
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation method,
the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• When using the product, observe the following conditions: Temperature from -30 ℃ to +50 ℃ for three-phase power supply models, from -10 ℃ to +50 ℃ for single-phase power supply models,
humidity 95% or less, elevation 1,000m or less, in a place where no corrosive or explosive gas or no steam is generated.
(from -30 ℃ to +50 ℃ for PFS-12BS1N and PFS-12BS2N)
(from -10 ℃ to +40 ℃ for PFS-20BT2A)

● A special silver acid-resistant coating has been applied to the motors.


* Various stainless steel type models other than the above can be manufactured. For models, please contact us.

■Special Specifications
Impeller Special order features
diameter Different Acid-resistant
Heat resistance Heat resistance (salt-resistant) MFP
(cm) Specified
voltage of 60 ℃ of 80 ℃ coating color treatment
25 × × × ○ ○ ×
30 ○ × × ○ ○ ×
40 ○ × × ○ ○ ×
50 ○ × × ○ ○ ×
• Different voltage features available for three-phase power supply models only

■Selection chart
[Exhaust type]
Single-phase, impeller diameter from 25 to 40cm
50Hz 60Hz
150 150
Static pressure (Pa)

Static pressure (Pa)

100 100
PF FS-
P

PF S-16
S- 16

PF
16 BS

S-
PF S

BS 2D

16 BS2
PF

PF S-1
S -12

PF
1D

BS D
-12 B

PF

S-1 2B

 50  50
PF

BSS2

1D
S-1

2B S2N

1NN
-10

0B

S1
BS

SD


  0 Air volume   0 Air volume


0 1000 2000 3000 4000 5000 (m3/h) 0 1000 2000 3000 4000 5000 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80

23
Pressure Fans Stainless Steel Type PFS
Three-phase, impeller diameter from 30 to 50cm
50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)


100 100
PF

-2
0B

PF
PF
PF
PF

PF
T2


S-1
S-1

-20

S-1
 50  50
-12

BT
6B

6B
BT

2B

2A
T2

T2
2N

T2



  0   0
Air volume Air volume
0 1000 2000 3000 4000 5000 6000 7000 8000 0 1000 2000 3000 4000 5000 6000 7000 8000
(m3/h) (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 0 10 20 30 40 50 60 70 80 90 100 110 120 130

■Assembly drawing
Fig.1 Fig.2 H MAX B
C
I E

C
D
E
A

G L

* The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Fig. Model A B C D E F G H I J L
PFS-10BSD 250 327 298 285 165 4×φ7 8×φ7 148.5 48 3 2PNCT×2 cores×0.75mm2×1m
PFS-12BS1N 300 378 349 330 210 4×φ7 8×φ7 159 60 3 VCT×2 cores×0.75mm2×1m
PFS-12BS2N 300 378 349 330 210 4×φ7 8×φ7 159 60 3 VCT×2 cores×0.75mm 2×1m
1 PFS-12BT2N 300 378 349 330 210 4×φ7 8×φ7 159 60 3 VCT×3 cores×0.75mm 2×1m
PFS-16BS1D 400 518 485 450 280 4×φ12 8×φ12 198 / 3 VCT×2 cores×0.75mm 2×1m
PFS-16BS2D 400 518 485 450 280 4×φ12 8×φ12 198 / 3 VCT×2 cores×0.75mm 2×1m
PFS-16BT2D 400 518 485 450 280 4×φ12 8×φ12 198 / 3 VCT×3 cores×0.75mm 2×1m
2 PFS-20BT2A 500 659 620 563 355 / 8×φ15 75 355 / 2PNCT×3 cores×1.25mm 2×1m

24
WPS All Stainless Steel Type Pressure Fans

■Applications
For refrigerator-freezer warehouses, unit coolers, and other places where rust-preventive
measures are required

■Feature
These pressure fans are equipped with low-temperature-spec motors with stainless steel
adopted for their outer shells, making them ideal for incorporating into unit coolers and
freezers in food, pharmaceutical and other factories.

WPS-12B
* Please note that the photo shows typical examples
and that they may partly differ from actual items.
■Specifications table
Power consumption Allowable current Starting current
Impeller Number Nominal Air volume (m3/h) (W) (A) (A) Noise (dB(A)) Approx.
Airflow Model diameter of poles Power supply output mass
direction (cm) (P) (V) (W) (kg)
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
Exhaust type

WPS-12B 30 50 1860 2200 44 60 0.4 0.4 0.6 0.6 45 49 6

WPS-16BT2D 4 Three-phase200 200 3800 4450 224 277 2.3 2.3 9.0 8.1 51 55 14
40
WPS-16BT2 250/400 4450 5450 345 470 2.25 2.3 9.0 8.1 62 66 15.5
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation
method, the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• Environment conditions (temperature and humidity) where the fan is installed are as follows. Observe these conditions when using the product.
• Temperature from -50 to +20 ℃, humidity 95% or less, elevation 1,000m or less

■Selection chart
[Exhaust type]
Three-phase, impeller diameter from 30 to 40cm
50Hz 60Hz
250 250

200 200
WP
W
Static pressure (Pa)

Static pressure (Pa)

S-1
PS

150 6B 150
T2
-1

D
6B
T2
D

100 100
W
PS

W
W

-1

PS
PS
W

6B

-1
PS

-1

50 50
T2

2B
2B
-1
6B
T2

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 6000 (m3/h) 0 1000 2000 3000 4000 5000 6000 (m3/h)
(m /min)
3
(m3/min)
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100

■Assembly drawing
B
Fig.1 Fig.2
C H MAX B
G D C
E H MAX D
F
E
G

A
C
E
C
D
E

L
L

* The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Fig. Model A B C D E F G H L

1 WPS-12B 300 378 349 330 210 4×φ7 8×φ7 179 2PNCT×4 cores×0.75mm 2×1m
1
1 WPS-16BT2D 400 518 485 450 280 4×φ12 8×φ12 303 SRCT×4 cores×1.25mm2×1m

2 WPS-16BT2 410 518 485 442 280 / 8×φ12 338 SRCT×4 cores×1.25mm2×1m
25
Pressure Fans Frameless Type TP
■Applications
For incorporating into oil coolers, unit coolers, and other equipment

■Feature
These pressure fans have been developed on the assumption of
incorporating into equipment without using mounting frames. They
are ideal for mounting to oil coolers and unit coolers, in particular,
and other equipment with small mounting space.

* Please note that the photo shows typical examples

■Specifications table
and that they may partly differ from actual items.

Power consumption Allowable current Starting current


Impeller Number Power Nominal Air volume (m3/h) (W) (A) (A) Noise (dB(A)) Approx.
Airflow Model diameter of poles supply output mass
direction (cm) (P) (W) (kg)
(V) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz

TP-12BT2K 30 1380 1680 66 80/86 0.42 0.42/0.43 1.0 0.96/1.05 41 44 3.2


50
TP-13B-1 33 2040 2340 88 100 0.56 0.51 1.1 1 53 56 3.5
4
Exhaust type

TP-14BT2G 35 100 2660 3150 102 122 1.0 1.0 2.9 2.7 43.5 47
Three-phase 7.4
TP-16BT2 200 200 3600 4230 240 290 1.38 1.38 5.4 5.2 54 58
40
6TP-16BT2 6 100 2700 3120 125 160 0.75 0.85 2.2 2.1 46 50 6.5
4TP-18B1 4 400 5880 6720 340 520 2 2.3 9.7 9.3 61 65 10
45
TP-18B 6 200 3840 4320 150 210 0.85 0.90 2.5 2.4 50 54 7.9

• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured in the JIS C 9603-compliant orifice chamber method.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation
method, the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Elevation 1,000m or less. Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• TP-16BT2, 6TP-16BT2, TP-18B: Temperature from -50 to +40 ℃, humidity 45 to 85%
• TP-12BT2K, TP-13B-1: Temperature from -50 to +40 ℃, humidity 45 to 95% or less
• TP-14BT2G: Temperature from -30 to +50 ℃, humidity 90% or less

■Selection chart
[Exhaust type]
Three-phase, impeller diameter from 30 to 45cm
50Hz
200

150
4T
TP


-18
-1

B1
6B
Static pressure (Pa)

T2

100
TP
-18

6T
 50 P
-16
TP
TP

BT
-14


TP
-12

BT
-13
BT

2G
2K

B1

  0 Air volume


0 1000 2000 3000 4000 5000 6000 (m3/h)
(m3/min)
0 10 20 30 40 50 60 70 80 90 100

26
TP Frameless Type Pressure Fans

■Selection chart
[Exhaust type]
Three-phase, impeller diameter from 30 to 45cm

60Hz
200

150 4T

-1

TP
8B

-16

BT
Static pressure (Pa)


100
TP
-18

6T

-1
6B
T2

 50
TP

TP
-12

-14
TP-1
BT

BT
2K

2G
3B1

  0 Air volume


0 1000 2000 3000 4000 5000 6000 7000 (m3/h)
(m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120

■Assembly drawing
Fig.1 Fig.2 Fig.3
F

F G
D

H
G

B
E × ×
H

C
C

B A

A
E

D
C
C

L
L

Fig.4 Fig.5

× ×

* The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Fig. Model A B C D E F G H L

1 TP-12BT2K 300 375 45° 9 15 137 109 102 XLPE×3 cores×0.5mm2×2m

2 TP-13B-1 330 410 45° 7 12 142 116 63 XLPE×3 cores×0.75mm2×2m

3 TP-14BT2G 350 470 45° 4×φ8.4 / 183 116.7 102 VCT×3 cores×0.75mm2×1m

4 TP-16BT2 400 477 45° 9 20 137 120 / XLPE×3 cores×0.75mm2×1.5m


4
4 6TP-16BT2 400 477 45° 9 20 141 120 / XLPE×3 cores×0.75mm2×1.5m

5 4TP-18B1 450 527 45° 9 20 185 138 120 2PNCT×3 cores×0.75mm2×3.8m

4 TP-18B 450 527 45° 9 20 143 128 / XLPE×3 cores×0.75mm2×2m

27
Pressure Fans Centrifugal Contact Type S
■Applications
For cubicles, important machinery, and other places where failure
alarms are required

■Feature
These pressure fans are ideal for cooling important equipment
requiring fan failure alarms, such as cubicles, communications
equipment, and transformers. They are equipped with centrifugal
contact switches so that signals can be output when fan
S-12BS2 S-16BT2G
revolutions decrease to 70 to 80% or less for some reason.
* Please note that the photo shows typical examples and that they may
■Specifications table partly differ from actual items.

Impeller Number Power Nominal Power consumption Allowable current Starting current Approx.
Airflow Air volume (m3/h) (W) (A) (A) Noise (dB(A))
Model diameter of poles supply output mass
direction (cm) (P) (V) (W) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz (kg)
S-10BS2 25 20 570 690 40 45 0.4 0.4 0.57 0.52 45 49 6
S-12BS2 30 Single-phase200 50 1098 1296 56 68 0.6 0.5 1.1 1 51 55 8
S-14BS2G 142 144 1.6 1.5 4.3 4.2
35 4 100 2660 3150 43.5 47 9.8
Exhaust type

S-14BT2G Three-phase200 102 122 1.25 1.15 4.1 3.9


S-16BS2G Single-phase200 4080 4680 200 250 1.8 1.8 4.3 4.2
40 200 46 50 11.5
S-16BT2G 4022 4543 162 227 1.2 1.2 4.1 3.9
S-18BT2A 45 250 5034 5802 210 310 2.3 3.0 6.5 5.7 54 58 23.5
Three-phase200
S-20BT2G 50 6 400 6120 7140 270 410 2.6 2.8 6.5 5.7 49 53 25
S-24BT2G 60 750 9420 11160 460 690 4.2 4.2 12 10 51 55.5 33.5
• The power consumption, air volume and noise figures mentioned above represent the values in the state of operation under free air conditions.
• The air volume has been measured using the JIS C 9603-compliant orifice chamber method.
• The noise figure represents the average of the values measured at three points that are 1.5 meters distant from one another. The value in actual operation varies depending on the installation method,
the duct form, and so on.
• The allowable current figure represents the critical point of operation. Use it for reference at the time of selecting a motor breaker.
• Make sure that the product is used in a place where no corrosive or explosive gas or no steam is generated.
• The fan should be installed in an environment where the temperature ranges from -20 ℃ to +50 ℃, the humidity is 85% or less, and the elevation is 1,000m or less. Observe these conditions
when using the product.

■Special Specifications
Impeller Special order features
diameter Different Acid-resistant
Heat resistance Heat resistance (salt-resistant) MFP
(cm) Specified
voltage of 60 ℃ of 80 ℃ coating color treatment
25 ○ ○ × ○ ○ ×
30 ○ ○ × ○ ○ ×
35 * ○ × ○ ○ ×
40 * ○ × ○ ○ ×
45 ○ ○ × ○ ○ ×
50 ○ ○ × ○ ○ ×
60 ○ ○ × ○ ○ ×
* 400 volt class available for three-phase power supply models only

■Selection chart
[Exhaust type]
Single-phase, impeller diameter from 25 to 40cm
50Hz 60Hz
150 150
Static pressure (Pa)

Static pressure (Pa)

100 100
S-
16
BS
S-
S-

2G
16
14

S-
S-1

BS

14
BS

BS
S-1

2G
2B

2G
2G
S-1

50 50
0B

S2
2

S2
S-1

BS
0

2
BS2

0 Air volume 0 Air volume


0 1000 2000 3000 4000 5000 (m3/h) 0 1000 2000 3000 4000 5000 (m3/h)
(m3/min) (m3/min)
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80

28
S Centrifugal Contact Type Pressure Fans

■Selection chart
[Exhaust type]
Three-phase, impeller diameter from 35 to 60cm
50Hz 60Hz
200 200

150 150
Static pressure (Pa)

Static pressure (Pa)


S-

S-
S-
18

24
100 100
24
S-

BT

BT
S-

S-2
BT
16

14

2
2G
A
BT

S-2

G
0B
BT
S-

2G

T2
S-16B
0B

2G
14

G
S-1
BT

T2

50 50
2G

8B
T2G

T2A
0 Air volume 0 Air volume
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 (m3/h) 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 (m3/h)
(m /min)3
(m3/min)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200

■Assembly drawing
H MAX B
Fig.1 Fig.2 C
D
E

C A TAT
RO
NOI
D
E
LECTRICW RKS.,.

LTD
O

KU
RITAE
Contact lead VSF 1m
Form A contact: Blue
Form B contact: Yellow Contact lead VSF 1m F
COM: White Form A contact: Blue
Form B contact: Yellow
COM: White G L

H MAX B
Fig.3 C
E

A
C
D
E

Contact lead VSF 1m


Form A contact: Blue G L
Form B contact: Yellow
COM: White * The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Fig. Model A B C D E F G H L
S-10BS2 250 327 298 271 165 / 8×φ7 245 2PNCT×2 cores×0.75mm 2×1m
1
S-12BS2 300 378 349 322 210 / 8×φ7 260 2PNCT×2 cores×0.75mm 2×1m
S-14BS2G 350 467 434 400 250 4×φ12 8×φ12 264 2PNCT×2 cores×0.75mm 2×1m
S-14BT2G 350 467 434 400 250 4×φ12 8×φ12 264 2PNCT×3 cores×0.75mm 2×1m
2
S-16BS2G 400 518 485 450 280 4×φ12 8×φ12 269 2PNCT×2 cores×0.75mm 2×1m
S-16BT2G 400 518 485 450 280 4×φ12 8×φ12 269 2PNCT×3 cores×0.75mm 2×1m
3 S-18BT2A 450 570 540 494 320 / 8×φ12 420 2PNCT×3 cores×1.25mm 2×1m
S-20BT2G 500 659 620 563 355 / 8×φ15 435 2PNCT×3 cores×1.25mm 2×1m
2
S-24BT2G 600 760 720 664 400 / 8×φ15 450 2PNCT×3 cores×1.25mm 2×1m

29
Pressure Fans Options Compatibility Table
■Standard Type
Impeller
diameter of Airflow Mounting Fixed louver Wind pressure shutter Motor-driven shutter Guard net
Model compatible direction Filter unit
pressure fans
frame Steel plate SUS Steel plate SUS Steel plate SUS Iron SUS Front face net
20 Exhaust TWBS- 8 LB- 8C LBS- 8C PS- 8C PSS- 8C − − GN- 8D1 − FGN- 8 3FU- 8A
cm Intake TWBS- 8 LB- 8C LBS- 8C − − − − GN- 8D1 − FGN- 8 3FU- 8A
25 Exhaust TWBS-10 LB-10C LBS-10C PS-10C PSS-10C MS-10D MSS-10D GN-10D1 GNS-10D1 FGN-10 3FU-10A
cm Intake TWBS-10 LB-10C LBS-10C − − MS-10D MSS-10D GN-10D1 GNS-10D1 FGN-10 3FU-10A
30 Exhaust TWBS-12 LB-12C LBS-12C PS-12C PSS-12C MS-12D MSS-12D GN-12D1 GNS-12D1 FGN-12 3FU-12A
cm Intake TWBS-12 LB-12C LBS-12C − − MS-12D MSS-12D GN-12D1 GNS-12D1 FGN-12 3FU-12A
35 Exhaust TWBS-14 LB-14C LBS-14C PS-14C PSS-14C MS-14D MSS-14D GN-14G GNS-14G FGN-14 3FU-14A
cm Intake TWBS-14 LB-14C LBS-14C − − MS-14D MSS-14D GN-14G GNS-14G FGN-14 3FU-14A
4P   PSS-16C
  PS-16C 4P *1 *2
40 Exhaust TWBS-16 LB-16C LBS-16C MS-16D MSS-16D GN-16G.G1 GNS-16G FGN-16 3FU-16A
cm 6P   6PSS-16
  6PS-16 6P
Intake TWBS-16 LB-16C LBS-16C − − MS-16D MSS-16D GN-16G.G1*1 GNS-16G*2 FGN-16 3FU-16A
45 Exhaust TWBS-18 LB-18C LBS-18C PS-18C PSS-18C MS-18C/D MSS-18C/D GN-18A-3 GNS-18 FGN-18 3FU-18A
PF cm Intake TWBS-18 LB-18C LBS-18C − − MS-18C/D MSS-18C/D GN-18A-3 GNS-18 FGN-18 3FU-18A
50 Exhaust TWBS-20 LB-20C LBS-20C PS-20C PSS-20C MS-20C/D MSS-20C/D GN-20A-3 GNS-20A FGN-20 3FU-20A
cm Intake TWBS-20 LB-20C LBS-20C − − MS-20C/D MSS-20C/D GN-20A-3 GNS-20A FGN-20 3FU-20A
  PSS-24C
  PS-24C 6P
6P
60 Exhaust TWBS-24 LB-24C LBS-24C MS-24D MSS-24D GN-24A-3 GNS-24A FGN-24 3FU-24A
  8PSS-24
  8PS-24 8P
8P
cm
Intake TWBS-24 LB-24C LBS-24C − − MS-24D MSS-24D GN-24A-3 GNS-24A FGN-24 3FU-24A
75 Exhaust TWBS-30 LB-30C LBS-30C PS-30C PSS-30C MS-30D MSS-30D GN-30S GNS-30 FGN-30 3FU-30A/B
cm Intake TWBS-30 LB-30C LBS-30C − − MS-30D MSS-30D GN-30S GNS-30 FGN-30 3FU-30A/B
90 Exhaust TWBS-36 LB-36C LBS-36C PS-36C PSS-36C MS-36D MSS-36D GN-36S GNS-36 FGN-36 3FU-36A/B
cm Intake TWBS-36 LB-36C LBS-36C − − MS-36D MSS-36D GN-36S GNS-36 FGN-36 3FU-36A/B

105 Exhaust
TWBS-42 LB-42C LBS-42C PS-42C PSS-42C MS-42D MSS-42D GN-42SG GNS-42SG FGN-42 −
cm Intake TWBS-42 LB-42C LBS-42C − − MS-42D MSS-42D GN-42SG GNS-42SG FGN-42 −
120 Exhaust − LB-48 LBS-48 − − − − GN-48 − FGN-48 −
cm Intake − LB-48 LBS-48 − − − − GN-48 − FGN-48 −
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.
*1: Holed type GN-16G1 is for PF-16B(A) T2F, and GN-16G is for other models.
*2: For PF-16B(A) T2F, please contact us.

Impeller Outdoor hood Fireproof hood


diameter of Airflow Without net With anti-insect net With anti-bird net Without net With anti-insect net With anti-bird net
Model compatible
pressure direction Steel plate SUS SUS
SUS Steel plate SUS (with rainwater Steel plate SUS (with rainwater SUS
fans gutter) gutter)

20 Exhaust OF- 8 OFS- 8 OF- 8NI OFS- 8NI − OF- 8NB OFS- 8NB − − − −
cm Intake − − − − OFS- 8ANI − − OFS- 8ANB − − −

25 Exhaust OF-10 OFS-10 OF-10NI OFS-10NI − OF-10NB OFS-10NB − − − −


cm Intake − − − − OFS-10ANI − − OFS-10ANB − − −

30 Exhaust OF-12 OFS-12 OF-12NI OFS-12NI − OF-12NB OFS-12NB − FDS-12 FDS-12NI FDS-12NB
cm Intake − − − − OFS-12ANI − − OFS-12ANB − − −

35 Exhaust OF-14 OFS-14 OF-14NI OFS-14NI − OF-14NB OFS-14NB − FDS-14 FDS-14NI FDS-14NB
cm Intake − − − − OFS-14ANI − − OFS-14ANB − − −

40 Exhaust OF-16 OFS-16 OF-16NI OFS-16NI − OF-16NB OFS-16NB − FDS-16 FDS-16NI FDS-16NB
cm Intake − − − − OFS-16ANI − − OFS-16ANB − − −

45 Exhaust OF-18 OFS-18 OF-18NI OFS-18NI − OF-18NB OFS-18NB − FDS-18 FDS-18NI FDS-18NB
cm Intake − − − − OFS-18ANI − − OFS-18ANB − − −
PF
50 Exhaust OF-20 OFS-20 OF-20NI OFS-20NI − OF-20NB OFS-20NB − FDS-20 FDS-20NI FDS-20NB
cm Intake − − − − OFS-20ANI − − OFS-20ANB − − −

60 Exhaust OF-24 OFS-24 OF-24NI OFS-24NI − OF-24NB OFS-24NB − FDS-24 FDS-24NI FDS-24NB
cm Intake − − − − OFS-24ANI − − OFS-24ANB − − −

75 Exhaust OF-30 OFS-30 OF-30NI OFS-30NI − OF-30NB OFS-30NB − FDS-30 FDS-30NI FDS-30NB
cm Intake − − − − OFS-30ANI − − OFS-30ANB − − −

90 Exhaust OF-36 OFS-36 OF-36NI OFS-36NI − OF-36NB OFS-36NB − FDS-36 FDS-36NI FDS-36NB
cm Intake − − − − OFS-36ANI − − OFS-36ANB − − −

105 Exhaust OF-42 OFS-42 OF-42NI OFS-42NI − OF-42NB OFS-42NB − FDS-42 FDS-42NI FDS-42NB
cm Intake − − − − OFS-42ANI − − OFS-42ANB − − −

120 Exhaust OF-48 OFS-48 OF-48NI OFS-48NI − OF-48NB OFS-48NB − − − −


cm Intake − − − − OFS-48ANI − − OFS-48ANB − − −

Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.
30
Compatibility Table Options Pressure Fans

■Outdoor Type
Impeller
diameter of Fixed louver Wind pressure shutter Motor-driven shutter Guard net
Airflow Mounting
Model compatible
direction frame Filter unit
pressure
fans Steel plate SUS Steel plate SUS Steel plate SUS Iron SUS Front face net

25 Exhaust TWBS-10 LB-10C LBS-10C − − − − GN-10 GNS-10 FGN-10 −


cm Intake TWBS-10 LB-10C LBS-10C − − − − GN-10 GNS-10 FGN-10 −

30 Exhaust TWBS-12 LB-12C LBS-12C − − − − GN-12 GNS-12 FGN-12 −


cm Intake TWBS-12 LB-12C LBS-12C − − − − GN-12 GNS-12 FGN-12 −

35 Exhaust TWBS-14 LB-14C LBS-14C − − − − GN-14G,G1*1 GNS-14G*2 FGN-14 −


cm Intake TWBS-14 LB-14C LBS-14C − − − − GN-14G,G1*1 GNS-14G*2 FGN-14 −

40 Exhaust TWBS-16 LB-16C LBS-16C − − − − GN-16G,G1*1 GNS-16G*2 FGN-16 −


cm Intake TWBS-16 LB-16C LBS-16C − − − − GN-16G,G1*1 GNS-16G*2 FGN-16 −

45 Exhaust TWBS-18 LB-18C LBS-18C − − − − GN-18A-3 GNS-18 FGN-18 −


cm Intake TWBS-18 LB-18C LBS-18C − − − − GN-18A-3 GNS-18 FGN-18 −
WP 50 Exhaust TWBS-20 LB-20C LBS-20C − − − − GN-20A-3 GNS-20A FGN-20 −
cm Intake TWBS-20 LB-20C LBS-20C − − − − GN-20A-3 GNS-20A FGN-20 −

60 Exhaust TWBS-24 LB-24C LBS-24C − − − − GN-24A-3 GNS-24A FGN-24 −


cm Intake TWBS-24 LB-24C LBS-24C − − − − GN-24A-3 GNS-24A FGN-24 −

75 Exhaust TWBS-30 LB-30C LBS-30C − − − − GN-30S GNS-30 FGN-30 −


cm Intake TWBS-30 LB-30C LBS-30C − − − − GN-30S GNS-30 FGN-30 −

90 Exhaust TWBS-36 LB-36C LBS-36C − − − − GN-36S GNS-36 FGN-36 −


cm Intake TWBS-36 LB-36C LBS-36C − − − − GN-36S GNS-36 FGN-36 −

105
Exhaust TWBS-42 LB-42C LBS-42C − − − − GN-42SG GNS-42SG FGN-42 −
cm Intake TWBS-42 LB-42C LBS-42C − − − − GN-42SG GNS-42SG FGN-42 −

120
Exhaust − LB-48 LBS-48 − − − − GN-48 − FGN-48 −
cm Intake − LB-48 LBS-48 − − − − GN-48 − FGN-48 −
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.
*1: The GN-14G1 and the GN-16G1 having a bypass hole are for single-phase power supply models, and the GN-14G and the GN-16G are for three-phase power supply models.
*2: For single-phase power supply models, please contact us.
Impeller Outdoor hood Fireproof hood
diameter of Airflow Without net With anti-insect net With anti-bird net Without net With anti-insect net With anti-bird net
Model compatible direction
SUS SUS
pressure Steel plate SUS Steel plate SUS (with rainwater Steel plate SUS (with rainwater SUS
fans gutter) gutter)

25 Exhaust OF-10 OFS-10 OF-10NI OFS-10NI − OF-10NB OFS-10NB − − − −


cm Intake − − − − OFS-10ANI − − OFS-10ANB − − −

30 Exhaust OF-12 OFS-12 OF-12NI OFS-12NI − OF-12NB OFS-12NB − FDS-12 FDS-12NI FDS-12NB
cm Intake − − − − OFS-12ANI − − OFS-12ANB − − −

35 Exhaust OF-14 OFS-14 OF-14NI OFS-14NI − OF-14NB OFS-14NB − FDS-14 FDS-14NI FDS-14NB
cm Intake − − − − OFS-14ANI − − OFS-14ANB − − −

40 Exhaust OF-16 OFS-16 OF-16NI OFS-16NI − OF-16NB OFS-16NB − FDS-16 FDS-16NI FDS-16NB
cm Intake − − − − OFS-16ANI − − OFS-16ANB − − −

45 Exhaust OF-18 OFS-18 OF-18NI OFS-18NI − OF-18NB OFS-18NB − FDS-18 FDS-18NI FDS-18NB
cm Intake − − − − OFS-18ANI − − OFS-18ANB − − −

WP 50 Exhaust OF-20 OFS-20 OF-20NI OFS-20NI − OF-20NB OFS-20NB − FDS-20 FDS-20NI FDS-20NB
cm Intake − − − − OFS-20ANI − − OFS-20ANB − − −

60 Exhaust OF-24 OFS-24 OF-24NI OFS-24NI − OF-24NB OFS-24NB − FDS-24 FDS-24NI FDS-24NB
cm Intake − − − − OFS-24ANI − − OFS-24ANB − − −

75 Exhaust OF-30 OFS-30 OF-30NI OFS-30NI − OF-30NB OFS-30NB − FDS-30 FDS-30NI FDS-30NB
cm Intake − − − − OFS-30ANI − − OFS-30ANB − − −

90 Exhaust OF-36 OFS-36 OF-36NI OFS-36NI − OF-36NB OFS-36NB − FDS-36 FDS-36NI FDS-36NB
cm Intake − − − − OFS-36ANI − − OFS-36ANB − − −

105 Exhaust OF-42 OFS-42 OF-42NI OFS-42NI − OF-42NB OFS-42NB − FDS-42 FDS-42NI FDS-42NB
cm Intake − − − − OFS-42ANI − − OFS-42ANB − − −

120 Exhaust OF-48 OFS-48 OF-48NI OFS-48NI − OF-48NB OFS-48NB − − − −


cm Intake − − − − OFS-48ANI − − OFS-48ANB − − −
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.

31
Pressure Fans Options Compatibility Table
■Pressure-Resistant Explosion-Proof Type
Impeller
diameter of Airflow Mounting Fixed louver Wind pressure shutter Motor-driven shutter Guard net
Model Filter unit
compatible
pressure fans
direction frame Steel plate SUS Steel plate SUS Steel plate SUS Iron SUS Front face net
20cm Exhaust TWBS- 8 LB- 8C LBS- 8C PS-8C PSS-8C − − EGN- 8 − FGN- 8 3FU- 8A
25 Exhaust TWBS-10 LB-10C LBS-10C PS-10C PSS-10C − − EGN-10 − FGN-10 3FU-10A
cm Intake TWBS-10 LB-10C LBS-10C − − − − EGN-10 − FGN-10 3FU-10A
30 Exhaust TWBS-12 LB-12C LBS-12C PS-12C PSS-12C − − EGN-12 − FGN-12 3FU-12A
cm Intake TWBS-12 LB-12C LBS-12C − − − − EGN-12 − FGN-12 3FU-12A
35 Exhaust TWBS-14 LB-14C LBS-14C PS-14C PSS-14C − − EGN-14 − FGN-14 3FU-14A
cm Intake TWBS-14 LB-14C LBS-14C − − − − EGN-14 − FGN-14 3FU-14A
  PS-16C 4P
4P   PSS-16C
40 Exhaust TWBS-16 LB-16C LBS-16C − − EGN-16 − FGN-16 3FU-16A
  6PS-16 6P
6P   6PSS-16
EPP cm
Intake TWBS-16 LB-16C LBS-16C − − − − EGN-16 − FGN-16 3FU-16A
45 Exhaust TWBS-18 LB-18C LBS-18C PS-18C PSS-18C − − EGN-18 − FGN-18 3FU-18A
cm Intake TWBS-18 LB-18C LBS-18C − − − − EGN-18 − FGN-18 3FU-18A
50 Exhaust TWBS-20 LB-20C LBS-20C PS-20C PSS-20C − − EGN-20 − FGN-20 3FU-20A
cm Intake TWBS-20 LB-20C LBS-20C − − − − EGN-20 − FGN-20 3FU-20A
60   PS-24C 6P
6P   PSS-24C
Exhaust TWBS-24 LB-24C LBS-24C − − EGN-24 − FGN-24 3FU-24A
cm   8PS-24 8P
8P   8PSS-24
75cm Exhaust TWBS-30 LB-30C LBS-30C PS-30C PSS-30C − − EGN-30 − FGN-30 3FU-30A/B
90cm Exhaust TWBS-36 LB-36C LBS-36C PS-36C PSS-36C − − EGN-36 − FGN-36 3FU-36A/B
105cm Exhaust TWBS-42 LB-42C LBS-42C PS-42C PSS-42C − − EGN-42 − FGN-42 −
120cm Exhaust − LB-48 LBS-48 − − − − EGN-48 − FGN-48 −
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
Impeller Outdoor hood Fireproof hood
diameter of Airflow Without net With anti-insect net With anti-bird net Without net With anti-insect net With anti-bird net
Model compatible direction SUS SUS
pressure Steel plate SUS Steel plate SUS (with rainwater Steel plate SUS (with rainwater SUS
fans gutter) gutter)
20cm Exhaust OF- 8 OFS- 8 OF- 8NI OFS- 8NI − OF- 8NB OFS- 8NB − − − −
25 Exhaust OF-10 OFS-10 OF-10NI OFS-10NI − OF-10NB OFS-10NB − − − −
cm Intake − − − − OFS-10ANI − − OFS-10ANB − − −
30 Exhaust OF-12 OFS-12 OF-12NI OFS-12NI − OF-12NB OFS-12NB − FDS-12 FDS-12NI FDS-12NB
cm Intake − − − − OFS-12ANI − − OFS-12ANB − − −
35 Exhaust OF-14 OFS-14 OF-14NI OFS-14NI − OF-14NB OFS-14NB − FDS-14 FDS-14NI FDS-14NB
cm Intake − − − − OFS-14ANI − − OFS-14ANB − − −
40 Exhaust OF-16 OFS-16 OF-16NI OFS-16NI − OF-16NB OFS-16NB − FDS-16 FDS-16NI FDS-16NB
EPP cm Intake − − − − OFS-16ANI − − OFS-16ANB − − −
45 Exhaust OF-18 OFS-18 OF-18NI OFS-18NI − OF-18NB OFS-18NB − FDS-18 FDS-18NI FDS-18NB
cm Intake − − − − OFS-18ANI − − OFS-18ANB − − −
50 Exhaust OF-20 OFS-20 OF-20NI OFS-20NI − OF-20NB OFS-20NB − FDS-20 FDS-20NI FDS-20NB
cm Intake − − − − OFS-20ANI − − OFS-20ANB − − −
60cm Exhaust OF-24 OFS-24 OF-24NI OFS-24NI − OF-24NB OFS-24NB − FDS-24 FDS-24NI FDS-24NB
75cm Exhaust OF-30 OFS-30 OF-30NI OFS-30NI − OF-30NB OFS-30NB − FDS-30 FDS-30NI FDS-30NB
90cm Exhaust OF-36 OFS-36 OF-36NI OFS-36NI − OF-36NB OFS-36NB − FDS-36 FDS-36NI FDS-36NB
105cm Exhaust OF-42 OFS-42 OF-42NI OFS-42NI − OF-42NB OFS-42NB − FDS-42 FDS-42NI FDS-42NB
120cm Exhaust OF-48 OFS-48 OF-48NI OFS-48NI − OF-48NB OFS-48NB − − − −
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.

■Stainless Steel Type


Impeller
diameter of Airflow Mounting Fixed louver Wind pressure shutter Motor-driven shutter Guard net
Model compatible direction Filter unit
pressure fans
frame Steel plate SUS Steel plate SUS Steel plate SUS Iron SUS Front face net
25cm Exhaust TWBS-10 − LBS-10C − PSS-10C − MSS-10D − GNS-10D1 − −
30cm Exhaust TWBS-12 − LBS-12C − PSS-12C − MSS-12D − GNS-12D1 − −
PFS
40cm Exhaust TWBS-16 − LBS-16C − PSS-16C − MSS-16D − GNS-16G − −
50cm Exhaust TWBS-20 − LBS-20C − PSS-20C − MSS-20D − GNS-20A − −
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.
Outdoor hood Fireproof hood
Impeller Airflow Without net With anti-insect net With anti-bird net Without net With anti-insect net With anti-bird net
Model diameter direction SUS SUS
Steel plate SUS Steel plate SUS (with rainwater
gutter)
Steel plate SUS (with rainwater
gutter)
SUS
25cm Exhaust − OFS-10 − OFS-10NI − − OFS-10NB − − − −
30cm Exhaust − OFS-12 − OFS-12NI − − OFS-12NB − FDS-12 FDS-12NI FDS-12NB
PFS
40cm Exhaust − OFS-16 − OFS-16NI − − OFS-16NB − FDS-16 FDS-16NI FDS-16NB
50cm Exhaust − OFS-20 − OFS-20NI − − OFS-20NB − FDS-20 FDS-20NI FDS-20NB
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.

■All Stainless Steel Type


32 * For options to WPS models, please contact us.
Compatibility Table Options Pressure Fans

■Centrifugal Contact Type


Impeller
diameter of Airflow Mounting Fixed louver Wind pressure shutter Motor-driven shutter Guard net
Model compatible direction Filter unit
pressure fans
frame Steel plate SUS Steel plate SUS Steel plate SUS Iron SUS Front face net
25cm Exhaust TWBS-10 LB-10C LBS-10C PS-10C PSS-10C MS-10D MSS-10D GN-10 − FGN-10 3FU-10A
30cm Exhaust TWBS-12 LB-12C LBS-12C PS-12C PSS-12C MS-12D MSS-12D GN-12 − FGN-12 3FU-12A
35cm Exhaust TWBS-14 LB-14C LBS-14C PS-14C PSS-14C MS-14D MSS-14D GN-14G1 − FGN-14 3FU-14A
S 40cm Exhaust TWBS-16 LB-16C LBS-16C PS-16C PSS-16C MS-16D MSS-16D GN-16G1 − FGN-16 3FU-16A
45cm Exhaust TWBS-18 LB-18C LBS-18C PS-18C PSS-18C MS-18D MSS-18D GN-18A-3 − FGN-18 3FU-18A
50cm Exhaust TWBS-20 LB-20C LBS-20C PS-20C PSS-20C MS-20D MSS-20D GN-20A-3 − FGN-20 3FU-20A
60cm Exhaust TWBS-24 LB-24C LBS-24C PS-24C PSS-24C MS-24D MSS-24D GN-24A-3 − FGN-24 3FU-24A
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.

Impeller Outdoor hood Fireproof hood


diameter of Airflow Without net With anti-insect net With anti-bird net Without net With anti-insect net With anti-bird net
Model compatible
pressure direction Steel plate SUS Steel plate SUS
SUS
(with rainwater Steel plate SUS
SUS
(with rainwater SUS
fans gutter) gutter)

25cm Exhaust OF-10 OFS-10 OF-10NI OFS-10NI − OF-10NB OFS-10NB − − − −


30cm Exhaust OF-12 OFS-12 OF-12NI OFS-12NI − OF-12NB OFS-12NB − FDS-12 FDS-12NI FDS-12NB
35cm Exhaust OF-14 OFS-14 OF-14NI OFS-14NI − OF-14NB OFS-14NB − FDS-14 FDS-14NI FDS-14NB
S 40cm Exhaust OF-16 OFS-16 OF-16NI OFS-16NI − OF-16NB OFS-16NB − FDS-16 FDS-16NI FDS-16NB
45cm Exhaust OF-18 OFS-18 OF-18NI OFS-18NI − OF-18NB OFS-18NB − FDS-18 FDS-18NI FDS-18NB
50cm Exhaust OF-20 OFS-20 OF-20NI OFS-20NI − OF-20NB OFS-20NB − FDS-20 FDS-20NI FDS-20NB
60cm Exhaust OF-24 OFS-24 OF-24NI OFS-24NI − OF-24NB OFS-24NB − FDS-24 FDS-24NI FDS-24NB
Note: Check the specifications of and models compatible with optional accessories prior to selection. Some products may not be used depending on the operating environment.
They may not be combined with some special pressure fan models.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.

■直流電源形
適応 固定ルーバー 風圧式シャッター 電動式シャッター ガードネット
機種 圧力扇 風向 取付枠 フィルター
羽根径 鋼板 ステンレス 鋼板 ステンレス 鋼板 ステンレス 鉄 ステンレス 前面用ネット ユニット
30 排気 TWBS-12 LB-12C LBS-12C PS-12C PSS-12C MS-12RD2 − GN-12D1 GNS-12D1 FGN-12 3FU-12A
cm 給気 TWBS-12 LB-12C LBS-12C − − MS-12RD2 − GN-12D1 GNS-12D1 FGN-12 3FU-12A
DCP
35 排気 TWBS-14 LB-14C LBS-14C PS-14C PSS-14C MS-14RD2 − GN-14G GNS-14G FGN-14 3FU-14A
cm 給気 TWBS-14 LB-14C LBS-14C − − MS-14RD2 − GN-14G GNS-14G FGN-14 3FU-14A
注意:オプション部品の仕様、適用機種を確認して選定してください。使用環境によって使用できない製品もあります。又、特殊圧力扇によっては、組合せ出来ない場合があります。
※ フードの電動式シャッター(内蔵用)付はお問合せください。

フード 防火フード
適応
機種 圧力扇 風向 網無し 虫網付 鳥網付 網無し 虫網付 鳥網付
羽根径 ステンレス ステンレス
鋼板 ステンレス 鋼板 ステンレス (雨どい付) 鋼板 ステンレス (雨どい付) ステンレス

30 排気 OF-12 OFS-12 OF-12NI OFS-12NI − OF-12NB OFS-12NB − FDS-12 FDS-12NI FDS-12NB


cm 給気 OF-12 OFS-12 OF-12NI OFS-12NI OFS-12ANI OF-12NB OFS-12NB OFS-12ANB − − −
DCP
35 排気 OF-14 OFS-14 OF-14NI OFS-14NI − OF-14NB OFS-14NB − FDS-14 FDS-14NI FDS-14NB
cm 給気 OF-14 OFS-14 OF-14NI OFS-14NI OFS-14ANI OF-14NB OFS-14NB OFS-14ANB − − −
注意:オプション部品の仕様、適用機種を確認して選定してください。使用環境によって使用できない製品もあります。又、特殊圧力扇によっては、組合せ出来ない場合があります。
※ フードの電動式シャッター(内蔵用)付はお問合せください。

33
Mounting Frames
Pressure Fans Options Fixed Louvers

Stainless Steel
■Mounting Frames ■Assembly drawing
* Please note that the photo shows typical □A
examples and that they may partly differ □C
B Top
from actual items. □D
E M N
F O

K
H
G

L
I
J Bottom

■Dimensions (Unit:mm)
Impeller diameter Plate Approx.
of compatible Model A B C D E F G H I J K L M N O mass
thickness (kg)
pressure fans
20cm TWBS-8 316 269 276 220 200 8×φ9 162 246 200 296 24 12 4×M6×25 1 0.6
25cm TWBS-10 367 347 327 275 200 8×φ9 165 298 200 347 24 12 4×M6×25 1 0.7
30cm TWBS-12 418 398 378 325 300 8×φ9 210 349 300 398 23 12 4×M6×25 2 1.5
35cm TWBS-14 530 500 467 400 320 8×φ12 250 434 320 500 28 12 4×M10×30 2 2.5
40cm TWBS-16 600 560 518 450 350 8×φ12 280 485 350 560 27.5 14 4×M10×30 2.5 4.0
45cm TWBS-18 630 600 570 500 400 8×φ12 540 320 320 540 400 600 27.5 14 8×M10×30 2.5 3.9
50cm TWBS-20 750 710 659 570 450 8×φ15 620 355 355 620 450 710 37 19 8×M12×40 3 7.5
60cm TWBS-24 820 790 760 670 500 8×φ15 720 400 400 720 500 790 37 19 8×M12×40 3 7.3
75cm TWBS-30 1020 990 955 840 600 8×φ20 900 508 508 900 600 990 47 19 8×M16×50 3 10.9
90cm TWBS-36 1220 1180 1114 990 710 8×φ20 1040 610 610 1040 710 1180 46 26 8×M16×50 4 21.3
105cm TWBS-42 1360 1320 1266 1150 800 8×φ20 1207 656 656 1207 800 1320 46 26 8×M16×50 4 22.4
* Spring washers,Taper washers, and nuts are not included.

Steel Plate Stainless Steel


■Fixed Louvers ■Assembly drawing
Serving as a simplified method of blocking incoming wind or covering the A F
air inlet at the time of installing a fan B Top
C
* Please note that the photo shows typical D E

examples and that they may partly differ


from actual items.
D

LB-14C
Bottom
* The shape varies slightly depending on the model.
* It cannot be used where it is directly exposed to rainwater.

■Dimensions (Unit:mm)
Impeller diameter Model Number Approx.
of compatible A B C D E F mass
pressure fans Steel Plate Stainless Steel of blades (kg)
20cm LB-8C LBS-8C 276 246 217 162 8×φ7 63 3 1.5
25cm LB-10C LBS-10C 327 298 268 165 8×φ7 63 4 1.9
30cm LB-12C LBS-12C 378 349 319 210 8×φ7 63 5 2.5
35cm LB-14C LBS-14C 467 434 389 250 8×φ12 75 5 4.3
40cm LB-16C LBS-16C 518 485 440 280 8×φ12 75 6 5.1
45cm LB-18C LBS-18C 570 540 492 320 8×φ12 75 6 5.7
50cm LB-20C LBS-20C 659 620 562 355 8×φ15 85 6 8.6
60cm LB-24C LBS-24C 760 720 663 400 8×φ15 85 7 12.4
75cm LB-30C LBS-30C 955 900 832 508 8×φ20 85 9 18
90cm LB-36C LBS-36C 1110 1040 980 610 8×φ20 85 9 24
105cm LB-42C LBS-42C 1262 1207 1132 656 8vφ20 85 10 28
120cm LB-48 LBS-48 1475 1425 1345 800 8×φ20 130 13 52

34
Wind Pressure Shutters
Motor-Driven Shutters Options Pressure Fans

Steel Plate Stainless Steel


■Wind Pressure Shutters
Helpful to blocking of incoming wind at the time of installing a fan
* Check the behavior of the wind pressure shutter after it is installed in a flat state.
* Use it in an environment where the temperature ranges from -10 ℃ to +60 ℃ and the relative humidity is 90% or less.
* Do not use it where it would be directly exposed to rainwater.
* It is not compatible with any intake-type pressure fan.
* The opening/closing angle varies depending on the air volume of the pressure fan used.
* Use a motor-driven shutter if the air volume is limited.

PS-18C
* Please note that the photo shows
typical examples and that they may
partly differ from actual items.

■Assembly drawing ■Dimensions (Unit:mm)


Impeller diameter
A H Model Number Approx.
B G Top of compatible
pressure fans Steel Plate Stainless Steel
A B C D E F G H of blades mass
(kg)
C
20cm PS-8C PSS-8C 276 246 220 217 162 8×φ7 63 95 2 1.5
E F
25cm PS-10C PSS-10C 327 298 271 268 165 8×φ7 63 95 3 2.1
30cm PS-12C PSS-12C 378 349 322 319 210 8×φ7 63 95 3 2.8
35cm PS-14C PSS-14C 467 434 392 389 250 8×φ12 75 110 4 4.1
40cm 4P PS-16C PSS-16C 518 485 443 440 280 8×φ12 75 110 4 4.9
D
E

40cm 6P 6PS-16 6PSS-16 518 485 440 440 280 8×φ12 75 115 6 2.9
45cm PS-18C PSS-18C 570 540 495 492 320 8×φ12 75 110 5 5.8
50cm PS-20C PSS-20C 659 620 565 562 355 8×φ15 85 120 5 8.2
Bottom 60cm 6P PS-24C PSS-24C 760 720 666 663 400 8×φ15 85 120 6 10.4
60cm 8P 8PS-24 8PSS-24 760 720 663 663 400 8×φ15 90 130 9 7.7
* The shape varies slightly depending on the model.
75cm PS-30C PSS-30C 955 900 833 830 508 8×φ20 85 140 8 17
90cm PS-36C PSS-36C 1110 1040 986 983 610 8×φ20 85 140 10 21
105cm PS-42C PSS-42C 1262 1207 1136 1133 656 8×φ20 85 140 11 25
Steel Plate Stainless Steel
■Motor-Driven Shutters
Incorporating a high-performance drive motor to guarantee unfailing operations; for blocking incoming wind or in combination with the air inlet or
an intake-type pressure fan
■Specifications table
Electric current Starting current Power consumption Opening time Closing time
Impeller diameter of
Voltage (A) (A) (W) (secs.) (secs.)
compatible Model
pressure fans (V) 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
100 0.1 or less 7 or less 8 7 Instant
25cm ∼ 40cm MS(S)-10D∼16D
200 0.07 or less 7 or less 8 7 Instant
45cm ∼ 50cm MS(S)-18C∼20C 100 0.43 0.30 0.45 0.35 18 13 6 5 6 5
45cm ∼ 105cm MS(S)-18D∼42D 200 0.81 0.47 0.82 0.52 57 36 5 4 5 4

* Check the behavior of the wind pressure shutter after it is installed in a flat state.
* It cannot be used where it is directly exposed to rainwater. Use an outdoor hood.
MS-16D * It cannot be fastened together with an outdoor hood or a fireproof hood. If you wish to fasten it together with any such hood, please contact us separately.
* Ranges of use are as follows:
An ambient temperature of -10 ℃ to +50 ℃ and a relative humidity of 90% or less for models compatible with pressure fans where an impeller diameter
* Please note that the photo shows typical
ranges from 25cm to 40cm;
examples and that they may partly differ An ambient temperature of -10 ℃ to +50 ℃ and a relative humidity of 90% or less under designations ending with C, and 85% or less under designations
from actual items. ending with D for models compatible with pressure fans where an impeller diameter ranges from 45cm to 60cm;
An ambient temperature of -10 ℃ to +50 ℃ and a relative humidity of 85% or less for models compatible with pressure fans where an impeller diameter
ranges from 75cm to 105cm.
* The built-in motor in the drive box of any motor-driven shutter compatible with pressure fans MS(S)-18D, 20D, and 24D where an impeller diameter ranges
from 45cm to 60cm, and MS(S)-30D, 36D, and 42D where an impeller diameter ranges from 75cm to 105cm includes a thermal fuse for motor protection.
Do not open and close the motor-driven shutter five consecutive times or more or for one continuous minute or longer, or the thermal fuse may blow to
protect the built-in motor. If the thermal fuse blows, the motor will no longer operate. In this case, the whole drive box including the built-in motor should
be replaced.

■Assembly drawing ■Dimensions (Unit:mm)


Impeller diameter Model Number Approx.
Top of compatible
Steel Plate Stainless Steel
A B C D E F G H of blades mass
pressure fans (kg)

25cm MS-10D MSS-10D 327 298 271 270 165 8×φ7 130 180 3 4
30cm MS-12D MSS-12D 378 349 322 321 210 8×φ7 130 190 3 4.5
35cm MS-14D MSS-14D 467 434 392 391 250 8×φ12 130 180 4 6
40cm MS-16D MSS-16D 518 485 443 442 280 8×φ12 130 190 4 6.5
MS-18C MSS-18C 10
45cm 570 540 495 494 320 8×φ12 130 190 5
MS-18D MSS-18D 10.5
MS-20C MSS-20C 11.5
50cm 659 620 565 564 355 8×φ15 130 190 5
MS-20D MSS-20D 12
Bottom 60cm MS-24D MSS-24D 760 720 666 665 400 8×φ15 130 190 6 14.5
75cm MS-30D MSS-30D 955 900 833 831 508 8×φ20 185 245 8 26
90cm MS-36D MSS-36D 1110 1040 986 984 610 8×φ20 185 245 10 32
* The shape varies slightly depending on the model.
105cm MS-42D MSS-42D 1262 1207 1136 1134 656 8×φ20 185 245 11 37
35
Pressure Fans Options Motor-Driven Shutters
■Example of Use of Operation Circuit
* Precautions
Please note the following.
Impeller diameter of compatible pressure fans Precautions
●Make sure that the power supply has the voltage specified on the rating plate.
25cm∼105cm
●If more than one pressure fan is operated, give consideration to the power supply capacity and other factors.

●While the motor-driven shutter is opening or closing, keep it powered on and never power it off.
●The built-in motor in the drive box of any motor-driven shutter compatible with pressure fans MS(S)-18D, 20D, and 24D where an impeller diameter ranges
from 45cm to 60cm, and MS(S)-30D, 36D, and 42D where an impeller diameter ranges from 75cm to 105cm includes a thermal fuse for motor protection. Do
45cm∼105cm not open and close the motor-driven shutter five consecutive times or more or for one continuous minute or longer, or the thermal fuse may blow to protect
the built-in motor. If the thermal fuse blows, the motor will no longer operate. In this case, the whole drive box including the built-in motor should be replaced.
● If the motor-driven shutter is powered off during the opening or closing operation, the motor-driven shutter will be stopped in a half-open state. To resume its
operation, power it on again.

●Do not operate the switch during the opening or closing operation. The motor-driven shutter is structured not to move on to the next operation unless the
opening or closing operation is finished. If the switch is operated during the opening or closing operation, the shutter will be stopped in a half-open state.
75cm∼105cm To restore its status, perform the switch operation again.
●Make sure that the pressure fan does not start operation until the motor-driven shutter becomes fully open.

* Examples of operation circuits for parallel operation of the motor-driven shutter and the pressure fan
MS(S)-10D∼16D MS(S)-10D∼16D
Circuits applicable to pressure fans Single-phase 100V and 200V Three-phase 200V
where an impeller diameter ranges from 25cm to 40cm Power supply Power supply
R S T

NFB NFB

MC MC

To be supplied To be supplied
by the customer by the customer

White Black White Black


●When the power supply is applied, the motor-driven shutter is in opening
Motor-driven shutter Motor-driven shutter
operation or in an open state. When the power is off, it is in closing
operation or in a closed state. Pressure fan Pressure fan

MS(S)-18C/D∼20C/D MS(S)-18D∼24D
Circuits applicable to pressure fans Single-phase 100V and 200V Three-phase 200V
where an impeller diameter ranges from 45cm to 60cm Power supply Power supply
R S T

NFB
NFB

MC
MC

To be supplied To be supplied
by the customer by the customer

White Red Black White Red Black

Motor-driven shutter Motor-driven shutter


●These examples of circuits are for motor-driven shutters with built-in relays. Pressure fan Pressure fan

MS(S)-30D∼42D
Circuits applicable to pressure fans Three-phase 200V
where an impeller diameter ranges from 75cm to 105cm Power supply
R S T

NFB1
NFB3

PB1
PB2
Ry
MC2 NFB2 Ry
T1

T2
●Set the time on Timer T1 to five seconds to ensure that the pressure fan MC1
Ry
will not come into operation until the motor-driven shutter becomes fully T2
MC1
T1
open. MC2
●After the power supply is cut off due to a power failure, etc., the shutter T1: 5 secs. T2: 10 secs.
To be supplied
by the customer
will close once and then open when the power is restored.
Set the time on Timer T2 to 10 seconds to ensure that the pressure fan White Red Black
will not start operation until five seconds of closing and another five
seconds of opening are finished. Motor-driven shutter
Pressure fan

36
Outdoor Hoods
Fireproof Hoods Options Pressure Fans

Steel Plate Stainless Steel


■Outdoor Hoods ■Assembly drawing
Blocking intrusion of not only wind and rain but insects and dust as well
by attaching an anti-insect or anti-bird net

OFS-12N
* Please note that the photo shows typical
examples and that they may partly differ from * The shape varies slightly depending on the model.
actual items.

To place an order for an outdoor hood with an anti-insect net, please add “I” at the ■Dimensions (Unit:mm)
end of the model code. For an outdoor hood with an anti-bird net, please add “B” at
the end of the model code. Impeller Model
diameter of Plate thickness
Notes: compatible Steel plate SUS A B C D E F
* Install at a height or in a place where the anti-insect or anti-bird net can be pressure fans
Without net With net Without net With net Steel plate SUS
maintained from outdoors. 20cm OF-8 OF-8N OFS-8 OFS-8N 275 226 246 162 220 8×φ7 1.2 0.8
* If you wish to install the hood at a height or in a place where there may be strong OFS-10 OFS-10N
25cm OF-10 OF-10N 327 278 298 165 300 8×φ7 1.2 0.8
outdoor wind, please contact us.
30cm OF-12 OF-12N OFS-12 OFS-12N 378 329 349 210 340 8×φ7 1.2 0.8
* Perform regular inspection of the anti-insect or anti-bird net. Perform regular
inspection and regular cleaning of the net to keep it unclogged from dust or the like. 35cm OF-14 OF-14N OFS-14 OFS-14N 464 404 434 250 390 8×φ12 1.2 0.8
* Although the hood is made of a SUS304 stainless steel plate, which is highly 40cm OF-16 OF-16N OFS-16 OFS-16N 515 455 485 280 410 8×φ12 1.2 0.8
resistant to rust, it is likely to rust in a salty or corrosive environment, such as a 45cm OF-18 OF-18N OFS-18 OFS-18N 570 510 540 320 440 8×φ12 1.2 1.0
place with any strong acid, alkaline or corrosive substance constantly in a wet state 50cm OF-20 OF-20N OFS-20 OFS-20N 659 580 620 355 490 8×φ15 1.6 1.0
or a place exposed to any such substance.
60cm OF-24 OF-24N OFS-24 OFS-24N 759 680 720 400 590 8×φ15 1.6 1.0
We also offer a model with acid- and salt-resistant coating and a model coated with
75cm OF-30 OF-30N OFS-30 OFS-30N 955 845 900 508 765 8×φ20 1.6 1.5
fluorocarbon resin (produced upon order) so that you may use it in an environment
as mentioned above. 90cm OF-36 OF-36N OFS-36 OFS-36N 1110 995 1040 610 900 8×φ20 1.6 1.5
* For outdoor hoods with a motor-driven shutter (built-in), please contact us. 105cm OF-42 OF-42N OFS-42 OFS-42N 1262 1145 1207 656 1000 8×φ20 1.6 1.5
120cm OF-48 OF-48N OFS-48 OFS-48N 1475 1365 1425 800 1180 8×φ20 1.6 1.5

Stainless Steel ■Assembly drawing


■Fireproof Hoods
Incorporating a fire damper to prevent spread of fire

FDS-12N
* Please note that the photo shows typical ●Japan Testing Center for Construction Materials Test Results Numbers
examples and that they may partly differ from Thermal fuse performance test at 72 ℃: No. 60570
actual items. Thermal fuse performance test at 120 ℃: No. 60624 (supplementary test)
Smoke leak test: No. 59766
To place an order for an outdoor hood with an anti-insect net, please add “I” at the * The shape varies slightly depending on the model.
end of the model code. For an outdoor hood with an anti-bird net, please add “B” at
the end of the model code. ■Dimensions (Unit:mm)
It cannot be fastened together with a motor-driven shutter or a wind pressure shutter.
Impeller
Notes: diameter of Model
compatible A B C D E F Plate thickness
* Install at a height or in a place where the anti-insect or anti-bird net can be pressure fans Without net With net
maintained from outdoors. 30cm FDS-12 FDS-12N 378 329 349 210 340 8×φ7 1.5
* If you wish to install the hood at a height or in a place where there may be strong FDS-14 FDS-14N
35cm 464 404 434 250 400 8×φ12 1.5
outdoor wind, please contact us.
40cm FDS-16 FDS-16N 515 455 485 280 420 8×φ12 1.5
* Perform regular inspection of the anti-insect or anti-bird net and the thermal fuse.
45cm FDS-18 FDS-18N 570 510 540 320 450 8×φ12 1.5
Perform regular inspection and regular cleaning of the net to keep it unclogged from
dust or the like. 50cm FDS-20 FDS-20N 659 580 620 355 505 8×φ15 1.5
* Although the hood is made of a SUS304 stainless steel plate, which is highly 60cm FDS-24 FDS-24N 759 680 720 400 615 8×φ15 1.5
resistant to rust, it is likely to rust in a salty or corrosive environment, such as a 75cm FDS-30 FDS-30N 995 845 900 508 780 8×φ20 1.5
place with any strong acid, alkaline or corrosive substance constantly in a wet state 90cm FDS-36 FDS-36N 1110 955 1040 610 885 8×φ20 1.5
or a place exposed to any such substance. FDS-42 FDS-42N
105cm 1262 1145 1207 656 925 8×φ20 1.5
We also offer a model with acid- and salt-resistant coating and a model coated
with fluorocarbon resin (produced upon order) so that you may use it in an
environment as mentioned above.

37
Intake Outdoor Hoods
Pressure Fans Options (with rainwater gutter)

Stainless Steel
■Intake Outdoor Hoods (with rainwater gutter)
Blocking incoming rainwater and intrusion of insects and dust

Notes:
* Install at a height or in a place where the anti-insect or anti-bird net can be maintained from outdoors.
* If you wish to install the hood at a height or in a place where there may be strong outdoor wind, please contact us.
* Perform regular inspection and regular cleaning of the anti-insect or anti-bird net to keep it unclogged from dust or the like.
* Although the hood is made of a SUS304 stainless steel plate, which is highly resistant to rust, it is likely to rust in a salty or corrosive
environment, such as a place with any strong acid, alkaline or corrosive substance constantly in a wet state or a place exposed to any such
substance. We also offer a model with acid- and salt-resistant coating and a model coated with fluorocarbon resin (produced upon order) so
that you may use it in an environment as mentioned above.
* Rainwater may intrude indoors depending on the place or state of installation or on weather conditions.
* For outdoor hoods with a motor-driven shutter (built-in), please contact us.
* Please note that the photo shows typical examples and that they may partly differ from actual items.

■Assembly drawing
□A
B
G C
F
H

D
E

J K L
I

Drainage direction

* The shape varies slightly depending on the model.

■Dimensions (Unit:mm)
Impeller diameter Model Plate
of compatible A B C D E F G H I J K L
pressure fans With anti-insect net With anti-bird net thickness
20cm OFS-8ANI OFS-8ANB 275 246 162 246 162 8×φ7 230 226 104 12 175 54 0.8
25cm OFS-10ANI OFS-10ANB 327 298 165 298 165 8×φ7 310 278 110 12 230 80 0.8
30cm OFS-12ANI OFS-12ANB 378 349 210 349 210 8×φ7 350 329 120 17 260 90 0.8
35cm OFS-14ANI OFS-14ANB 464 434 250 434 250 8×φ12 400 404 140 17 310 90 0.8
40cm OFS-16ANI OFS-16ANB 515 485 280 485 280 8×φ12 420 455 153 17 320 100 0.8
45cm OFS-18ANI OFS-18ANB 570 540 320 540 320 8×φ12 450 510 200 17 350 100 1.0
50cm OFS-20ANI OFS-20ANB 659 620 355 620 355 8×φ15 500 580 200 23 400 100 1.0
60cm OFS-24ANI OFS-24ANB 759 720 400 720 400 8×φ15 600 680 204 23 500 100 1.0
75cm OFS-30ANI OFS-30ANB 955 900 508 900 508 8×φ20 775 845 303 22 655 120 1.5
90cm OFS-36ANI OFS-36ANB 1110 1040 610 1040 610 8×φ20 910 995 302 22 760 150 1.5
105cm OFS-42ANI OFS-42ANB 1262 1207 656 1207 656 8×φ20 1010 1145 304 22 800 210 1.5
120cm OFS-48ANI OFS-48ANB 1475 1425 800 1425 800 8×φ20 1190 1365 300 20 990 200 1.5

38
Guard net Options Pressure Fans

Iron Stainless Steel


■Guard Nets
Guard nets prevent accidents of contacting the rotating part of the pressure fan. As they are designed
exclusively for specific models of pressure fans, please choose the model matched with the fan model.
Make sure to install a guard net if the pressure fan is installed at a height of 1.8 meters or less.

GN-12D1
* Please note that the photo shows typical examples and that they may partly differ from actual items.

●Standard Net
■Assembly drawing
A
Fig.1 Fig.2 B
D
E

(142)

C
(140)

* The shape varies slightly depending on the model.


Materials: Iron wire and stainless steel wire Materials: Iron wire
Surface treatment : PE coating N7 for iron wire Surface treatment: PE coating N7
; No treatment for stainless steel wire

Fig.3 Fig.4

* The shape varies slightly depending on the model. * The shape varies slightly depending on the model. Net: Expanded metal
Materials: Iron wire and stainless steel wire
Surface treatment : PE coating N7 for iron wire
; No treatment for stainless steel wire

■Dimensions (Unit:mm)
Impeller diameter of
Materials compatible pressure fans Fig. Model A B B’ C D E F
20cm 1 GN-8D1 264 246 162 170 119
1 GN-10D1 316 298 165 170 119
25cm
4 GN-10 327 284 310 298 165 245 4×φ7
1 GN-12D1 372 349 210 175 119
30cm
4 GN-12 378 335 360 349 210 265 4×φ7
1 GN-14G 458 434 250 210 166
35cm
2 GN-14G1 458 434 250 210 166
1 GN-16G 509 485 280 225 176
Iron

40cm
2 GN-16G1 509 485 280 225 176
45cm 3 GN-18A-3 520 520 540 320 420 8×φ12
50cm 3 GN-20A-3 592 592 620 355 425 8×φ15
60cm 3 GN-24A-3 698 698 720 400 455 8×φ15
75cm 4 GN-30S 951 870 870 900 508 470 4×φ20
90cm 4 GN-36S 1090 1028 1028 1040 610 450 4×φ20
105cm 4 GN-42SG 1257 1183 1183 1207 656 570 4×φ20
120cm 4 GN-48 1372 1532 1532 1425 800 550 4×φ20
1 GNS-10D1 316 298 165 170 119
25cm
4 GNS-10 327 284 310 298 165 245 4×φ9
1 GNS-12D1 372 349 210 175 119
30cm
4 GNS-12 378 335 360 349 210 300 4×φ7
Stainless Steel

35cm 1 GNS-14G 458 434 250 210 166


40cm 1 GNS-16G 509 485 280 225 176
45cm 4 GNS-18 570 518 550 540 320 400 4×φ12
50cm 3 GNS-20A 592 592 620 355 425 8×φ12
60cm 3 GNS-24A 698 698 720 400 455 8×φ12
75cm 4 GNS-30 951 870 890 900 508 470 4×φ20
90cm 4 GNS-36 1090 1028 1060 1040 610 450 4×φ20
105cm 4 GNS-42SG 1257 1183 1183 1207 656 570 4×φ20
* For applicable models, refer to compatibility tables and dimensional outline drawings.
* The GN-14G1 and the GN-16G1 each have a bypass hole for the motor.

39
Pressure Fans Options Guard net
●Explosion-Proof Net (E Series)
■Assembly drawing
A A
Fig.1 C E Fig.2 C E
B
B

D
F

※形状は機種により多少異なります。
* The shape varies slightly depending on the model. Net:
ネット:エExpanded metal
キ ス パ ンドメタ ル ※形状は機種により多少異なります。
* The shape varies slightly depending on the model. ネット
Net::エExpanded metal
キ ス パ ンドメタ ル

■Dimensions (Unit:mm)
Impeller diameter of
compatible pressure fans Fig. Model A B C D E F
20cm 2 EGN-8 270 242 246 162 210 4×φ7
25cm 2 EGN-10 327 291 298 165 211 4×φ9
30cm 2 EGN-12 378 342 349 210 236 4×φ9
35cm 1 EGN-14 467 410 434 250 365 4×φ12
40cm 1 EGN-16 518 461 485 280 365 4×φ12
45cm 1 EGN-18 570 513 540 320 430 4×φ12
50cm 1 EGN-20 659 589 620 355 445 4×φ15
60cm 1 EGN-24 760 699 720 400 480 4×φ15
75cm 1 EGN-30 951 870 900 508 505 4×φ20
90cm 1 EGN-36 1090 1028 1040 610 480 4×φ20
105cm 1 EGN-42 1257 1183 1207 656 495 4×φ20
120cm 1 EGN-48 1381 1525 1425 800 600 4×φ20
* The EGN-12 is different in the shape of the bypass hole for the motor between single-phase power supply
and three-phase power supply models.

●Front Face Net (F Series)


■Assembly drawing

Net: Expanded metal

■Dimensions (Unit:mm)
Impeller diameter of
compatible pressure fans Model A B C D E F
20cm FGN-8 274 224 246 162 7 8×φ7
25cm FGN-10 325 275 298 165 7 8×φ7
30cm FGN-12 376 326 349 210 7 8×φ7
35cm FGN-14 465 389 434 250 8 8×φ12
40cm FGN-16 516 440 485 280 8 8×φ12
45cm FGN-18 568 492 540 320 8 8×φ12
50cm FGN-20 658 582 620 355 8 8×φ15
60cm FGN-24 758 682 720 400 8 8×φ15
75cm FGN-30 955 825 900 508 10 8×φ20
90cm FGN-36 1110 980 1040 610 10 8×φ20
105cm FGN-42 1262 1132 1207 656 10 8×φ20
120cm FGN-48 1475 1345 1425 800 10 8×φ20

40
Filter Unit Options Pressure Fans

■Filter Unit
Designed exclusively for pressure fans to guarantee smooth installation and easy maintenance

Filter insertion diagram

Filter Unit

3FU-12A
* Please note that the photo shows typical examples
and that they may partly differ from actual items.

■Selection Diagrams The diagram represents initial pressure loss characteristics.


80
A

A
A

A
3FU-8A

3FU-10

3FU-12

3FU-14

3FU-16
3FU-18

3FU-20

3FU-24

3FU-30

3FU-36
60

B
Pressure loss (Pa)

B
3FU-30

3FU-36
40

20

0 Air volume
0 2 4 6 8 10 20 40 60 80 100 200 400 (m3/min)

●Trapping efficiency 3FS-8∼36 Initial dust collection efficiency 64% (at a wind speed of 2.5m/s)
3FP-30,36 Initial dust collection efficiency 28% (at a wind speed of 1.5m/s) 

■Assembly drawing

●Filter case ●Filter

■Dimensions (Unit:mm)

Impeller
Filter unit diameter of Filter case Filter
compatible
Model pressure fans Model A B C D E F Model L M N
3FU-8A 20cm FC-8 276 216 246 162 150 2×8×φ7 3FS-8 210 50 170
3FU-10A 25cm FC-10 327 267 298 165 150 2×8×φ7 3FS-10 260 50 220
3FU-12A 30cm FC-12 378 318 349 210 150 2×8×φ7 3FS-12 313 50 273
3FU-14A 35cm FC-14 467 387 434 250 150 2×8×φ12 3FS-14 382 50 342
3FU-16A 40cm FC-16 518 438 485 280 150 2×8×φ12 3FS-16 432 50 392
3FU-18A 45cm FC-18 570 490 540 320 150 2×8×φ12 3FS-18 482 50 442
3FU-20A 50cm FC-20 659 559 620 355 150 2×8×φ15 3FS-20 552 50 512
3FU-24A 60cm FC-24 760 660 720 400 150 2×8×φ15 3FS-24 652 50 612
3FU-30A 75cm 3FS-30
FC-30 955 825 900 508 150 2×8×φ20 818 50 778
3FU-30B 75cm 3FP-30
3FU-36A 90cm 3FS-36
FC-36 1110 980 1040 610 150 2×8×φ20 972 50 932
3FU-36B 90cm 3FP-36

41
Pressure Fans Model Development Table
■Precautions for Use
1) This table shows the sales launch and termination years of cataloged products as guidelines, as well as replacement products. For your individual product, check the fabrication specifications with the product nameplate, delivery
drawing, or the like to determine a replacement product.
2) Make sure to check the specifications because some products are fabricated according to specific manufacturers’ specifications under the same model codes as standard products.
3) The explosion-proof pressure fan series can be replaced as-is after checking the power supply details (single-phase or three-phase, voltage, and frequency) because they are unchanged in specifications.
4) Since the S series has several types of centrifugal contacts, check the fabrication specifications of your individual product with the product nameplate, delivery drawing, or the like to see if the existing product can be used.

■Sales Launch Year ■Description of types

PF - 14 B T 2 G
Old model 1953
(Example)
35cm standard pressure fan, three-phase 200V, G series
NewPF A series 1982
Flat D series 1986 ⑦ ① ② ③ ④ ⑤ ⑥ ⑧
Powerful G series 1996 ①Model type PF: Standard type (different voltage type)/WP: Outdoor type
New motor G series 2006 ②Impeller diameter Indicated in inches; For a value in centimeters, multiply the value in inches by 2.5.
Low noise N series 2017 ③Airflow direction B: Exhaust/A: Intake * When facing the front of the impeller, exhaust air flows frontward, and intake air flows backward.
④Power supply S: Single-phase/T: Three-phase
⑤Voltage 1: 100 volt class/2: 200 volt class/4: 400 volt class
⑥Series code Ascending alphabetical order
⑦Number of poles None: Standard/Number specified: Multiple-pole type (6: six poles, 8: eight poles)
⑧ID code None, 1, 2...
Old model products are designated as PF-14B.

■Impeller diameter Sales period


Impeller Number Sales
diameter Type Product model of phases Voltage Frequency Assembly drawing Existing model Assembly drawing Sales launch year termination year 1950s 1960s 1970s 1980s 1990s 2000s 2010s
PF-8ASA 1 100 PFA-201A A1984-01 1982 1986
PF-8AS1D
100 PFA-201B A1984-01
PF-8ASB 1 1982 1986
200 PFA-202B PF-8AS2D A1984-02
100 A209-05 PF-8AS1D A1984-01
PF-8ASD 1 1986 2015
200 A209-06 PF-8AS2D A1984-02
Standard 100 D-23759 PF-8BS1D A1977-01
20cm Type PF-8B 1
200 D-23759 PF-8BS2D A1977-02
1953 1981

PF-8BF 1 200 A442-01 PF-8BF2 A1995-02 1988 2015


100 PFB-201B PF-8BS1D A1977-01
PF-8BSB 1 1982 1985
200 PFB-202B PF-8BS2D A1977-02
100 A208-06 PF-8BS1D A1977-01
PF-8BSD 1 1986 2015
200 A208-07 PF-8BS2D A1977-02
100 D-23572 PF-10AS1D A1985-01
PF-10A 1 1953 1981
200 D-23571 PF-10AS2D A1985-02
100 PFA-251A PF-10AS1D A1985-01
PF-10ASA 1
200 PFA-252A PF-10AS2D A1985-02
1982 1985
100 PFA-251B PF-10AS1D A1985-01
PF-10ASB 1
200 PFA-252B PF-10AS2D A1985-02
100 A211-05 PF-10AS1D A1985-01
PF-10ASD 1 1986 2016
200 A211-06 PF-10AS2D A1985-02
Standard 100 A674-02 A674-02 ー
Type PFS-10ASD 1
200 A674-03
PFS-10ASD
A674-03
1990

100 D-23398 PF-10BS1D A1978-01
25cm PF-10B 1 1953 1981
200 D-23398 PF-10BS2D A1978-02
100 PFB-251B PF-10BS1D A1978-01
PF-10BSB 1 1982 1985
200 PFB-252B PF-10BS2D A1978-02
100 A210-06 PF-10BS1D A1978-01
PF-10BSD 1 1986 2016
200 A210-07 PF-10BS2D A1978-02
100 A308-04 A308-04 ー
PFS-10BSD 1 PFS-10BSD 1988
200 A308-08 A308-08 ー
100 C411-01 C411-01 ー
WP-10A 1 WP-10A
Outdoor 200 C411-05 C411-05 ー
Type 1953
100 C279-01 C279-01 ー
WP-10B 1 WP-10B
200 C279-05 C279-05 ー
100 D-23622 PF-12AS1N A2073-01
1
PF-12A 200 D-23785 PF-12AS2N A2073-02 1953 1981
3 200 D-23412 PF-12AT2N A2074-01
100 PFA-301A PF-12AS1N A2073-01
PF-12ASA 1
200 PFA-302A PF-12AS2N A2073-02
1982 1985
100 PFA-301B PF-12AS1N A2073-01
PF-12ASB 1
200 PFA-302B PF-12AS2N A2073-02
100 A227-08 PF-12AS1N A2073-01
PF-12ASD 1 1986 1995
Standard 200 A227-09 PF-12AS2N A2073-02
30cm Type 100 A999-05 PF-12AS1N A2073-01
PF-12ASG 1 1996 2005
200 A999-06 PF-12AS2N A2073-02
PF-12AS1D 1 100 A1765-01 PF-12AS1N A2073-01 2006 2016
PF-12AS2D 1 200 A1765-02 PF-12AS2N A2073-02 2006 2016
PF-12AS1D1 1 100 A2003-01 PF-12AS1N A2073-01 2016 2017
PF-12AS2D1 1 200 A2003-02 PF-12AS2N A2073-02 2016 2017
100 A638-04 PFS-12AS1N A2082-01
PFS-12ASD 1 1986 1995
200 A638-05 PFS-12AS2N A2082-02

42
Model Development Table Pressure Fans

Sales period
Impeller Number Sales
diameter Type Product model of phases Voltage Frequency Assembly drawing Existing model Assembly drawing Sales launch year termination year 1950s 1960s 1970s 1980s 1990s 2000s 2010s
PF-12ATB 3 200 PFA-303B A2074-01 1982 1985
PF-12AT2N
200 A228-11 A2074-01
PF-12ATD 3 1986 1995
400 ー PF-12AT4N A2074-02
200 A1000-02 PF-12AT2N A2074-01
PF-12ATG 3 1996 2005
400 ー PF-12AT4N A2074-02
PF-12AT2D 3 200 A1766-01 PF-12AT2N A2074-01 2006 2016
PF-12AT4D 3 400 A1766-02 PF-12AT4N A2074-02 2006 2016
PF-12AT2D1 3 200 A2004-01 PF-12AT2N A2074-01 2016 2017
200 A712-02 PFS-12AT2N A2083-01
PFS-12ATD 3 1986 2017
400 A712-04 PFS-12AT4N A2083-02
100 D-23632 PF-12BS1N A2071-01
1
PF-12B 200 D-23632 PF-12BS2N A2071-02 1953 1981
3 200 D-23616 PF-12BT2N A2072-01
100 PFB-301B PF-12BS1N A2071-01
PF-12BSB 1 1982 1985
200 PFB-302B PF-12BS2N A2071-02
100 A225-05 PF-12BS1N A2071-01
Standard PF-12BSD 1
200 A225-06 PF-12BS2N A2071-02
1986 1995
Type
100 PFB-301S PF-12BS1N A2071-01
PF-12BSS 1 1982 1985
200 PFB-302S PF-12BS2N A2071-02
30cm
100 ー PF-12BS1N A2071-01
PF-12BSE 1 1986 1995
200 ー PF-12BS2N A2071-02
100 A992-05 PF-12BS1N A2071-01
PF-12BSG 1 1996 2005
200 A992-06 PF-12BS2N A2071-02
PF-12BS1G 1 100 A1763-01 PF-12BS1N A2071-01 2006 2016
PF-12BS2G 1 200 A1763-02 PF-12BS2N A2071-02 2006 2016
PF-12BS1G1 1 100 A1991-01 PF-12BS1N A2071-01 2016 2017
PF-12BS2G1 1 200 A1991-02 PF-12BS2N A2071-02 2016 2017
PFS-12BSD 1 100 A309-03 PFS-12BS1N A2080-01 1988 2017
PF-12BTB 3 200 PFB-303B 1982 1985
PF-12BTD 3 200 A226-15 PF-12BT2N A2072-01 1986 1995
200 A993-03
PF-12BTG 3 1996 2005
400 ー PF-12BT4N A2072-02
PF-12BTS 3 200 PFB-303S PF-12BT2N A2072-01 1982 1985
PF-12BT2G 3 200 A1764-01 PF-12BT2N A2072-01 2006 2016
PF-12BT4G 3 400 A1764-02 PF-12BT4N A2072-02 2006 2016
PF-12BT2G1 3 200 A1992-01 PF-12BT2N A2072-01 2016 2017
PFS-12BT2D 3 200 A1983-02 PFS-12BT2N A2081-01 2016 2017
100 C254-01 C254-01
Outdoor WP-12A 1 WP-12A 1953 ー
200 C254-04 C254-04
Type
100 C506-01 C506-01
WP-12B 1 WP-12B 1953 ー
200 C506-02 C506-02
100 D-23800 PF-14AS1N A2107-01
1
PF-14A 200 D-23800 PF-14AS2N A2107-02 1953 1981
3 200 D-23684 PF-14AT2N A2108-01
100 PFA-351A PF-14AS1N A2107-01
PF-14ASA 1 1982 1985
200 PFA-352A PF-14AS2N A2107-02
100 A191-05 PF-14AS1N A2107-01
PF-14ASD 1 1986 1995
200 A191-06 PF-14AS2N A2107-02
100 A1030-03 PF-14AS1N A2107-01
PF-14ASG 1 1996 2005
200 A1030-04 PF-14AS2N A2107-02
PF-14ATA 3 200 PFB-353A PF-14AT2N A2108-01 1982 1985
PF-14ATD 3 200 A192-01 PF-14AT2N A2108-01 1986 1995
PF-14ATG 3 200 A1029-02 PF-14AT2N A2108-01 1996 2005
PF-14AS1D 1 100 A1602-01 PF-14AS1N A2107-01
PF-14AS2D 1 200 A1602-02 PF-14AS2N A2107-02 2006 2018
Standard PF-14AT2D 3 200 A1603-01 PF-14AT2N A2108-01
Type 100 D-23851 PF-14BS1N A2105-01
1
PF-14B 200 D-23851 PF-14BS2N A2105-02 1953 1981
35cm 3 200 D-23725 PF-14BT2N A2106-01
100 PFB-351A PF-14BS1N A2105-01
PF-14BSA 1 1982 1985
200 PFB-352A PF-14BS2N A2105-02
100 A189-08 PF-14BS1N A2105-01
PF-14BSD 1 1986 1995
200 A189-09 PF-14BS2N A2105-02
100 A1028-04 PF-14BS1N A2105-01
PF-14BSG 1 1996 2005
200 A1028-05 PF-14BS2N A2105-02
PF-14BTA 3 200 PFB-353A PF-14BT2N A2106-01 1982 1985
PF-14BTD 3 200 A190-05 PF-14BT2N A2106-01 1986 2005
200 A1027-02 PF-14BT2N A2106-01
PF-14BTG 3 1996 2005
400 ー PF-14BT4N A2106-02
PF-14BS1G 1 100 A1595-01 PF-14BS1N A2105-01
PF-14BS2G 1 200 A1595-02 PF-14BS2N A2105-02 2006 2018
PF-14BT2G 3 200 A1596-01 PF-14BT2N A2106-01
WP-14A 1 100 WP-14AS1D 1953 1981
Outdoor 100 C422-01 WP-14AS1D
Type WP-14ASA 1
200 C422-02 WP-14AS2D 1982 2005
WP-14ATA 3 200 C360-01 WP-14AT2D

43
Pressure Fans Model Development Table

Sales period
Impeller Number Sales
diameter Type Product model of phases Voltage Frequency Assembly drawing Existing model Assembly drawing Sales launch year termination year 1950s 1960s 1970s 1980s 1990s 2000s 2010s
100 C-24138 WP-14BS1G C938-01
1 1953
WP-14B 200 C-24138 WP-14BS2G C938-02 2005
Outdoor 3 200 C-24135 WP-14BT2G C941-01
35cm Type 1982
100 C306-01 WP-14BS1G C938-01
WP-14BSA 1
200 C306-02 WP-14BS2G C938-02 1982 2005
WP-14BTA 3 200 C307-01 WP-14BT2G C941-01
100 D-23625 PF-16AS1D
1
PF-16A 200 D-23625 PF-16AS2D 1953 1981
3 200 D-23839 PF-16AT2D
100 PFA-401A PF-16AS1D
PF-16ASA 1 1982 1985
200 PFA-402A PF-16AS2D
100 50 PFA-401C 6PF-16AS1D
PF-16ASC 1 1982 1985
200 PFA-402C 6PF-16AS2D
100 A195-06 PF-16AS1D
PF-16ASD 1 1986 1995
200 A195-07 PF-16AS2D
100 A199-05 6PF-16AS1D
PF-16ASE 1 1986 1995
200 A199-06 6PF-16AS2D
100 A1034-03 PF-16AS1D
PF-16ASG 1 1996 2005
200 A1034-04 PF-16AS2D
100 A732-05 PFS-16AS1D
PFS-16ASD 1 1986 2005
200 A732-06 PFS-16AS2D
PF-16ATA 3 200 PFA-403A PF-16AT2D 1982
1985
PF-16ATC 3 200 PFA-403C 6PF-16AT2D 1982
PF-16ATD 3 200 A196-06 PF-16AT2D 1986
1995
PF-16ATE 3 200 A200-04 6PF-16AT2D 1986
200 A868-04 PF-16AT2F A1610-01
PF-16ATF 3 1994 2005
400 A868-05 PF-16AT4F A1610-12
PF-16ATG 3 200 A1033-03 PF-16AT2D 1996
2005
PF-16ATH 3 200 A1037-02 PF-16AT2D 1996
PF-16ATS 3 200 PFA-403S PF-16AT2D 1982 1985
200 A687-06 PFS-16AT2D A1657-01
PFS-16ATD 3 1990 2005
400 ー PFS-16AT4D A1657-03
100 D-23619 PF-16BS1G
1
PF-16B 200 D-23619 PF-16BS2G 1953 1981
Standard
Type 3 200 D-23620
100 PFB-401A PF-16BS1G
PF-16BSA 1 1982 1985
200 PFB-402A PF-16BS2G
100 PFB-401C 6PF-16BS1G
PF-16BSC 1 1982 1985
200 PFB-402C 6PF-16BS2G
100 A193-11 PF-16BS1G
PF-16BSD 1 1986 1995
40cm 200 A193-12 PF-16BS2G
100 A197-05 6PF-16BS1G
PF-16BSE 1 1986 1995
200 A197-06 6PF-16BS2G
100 A1032-04 PF-16BS1G
PF-16BSG 1 1996 2005
200 A1032-05 PF-16BS2G
100 A1036-03 6PF-16BS1G
PF-16BSH 1 1996 2005
200 A1036-04 6PF-16BS2G
100 PFB-401S PF-16BS1G
PF-16BSS 1 1982 1985
200 PFB-402S PF-16BS2G
100 A311-05 PFS-16BS1D
PFS-16BSD 1 1988 2005
200 ー PFS-16BS2D
PF-16BTA 3 200 A499-02 PF-16BT2G 1982 1985
PF-16BTB 3 200 A373-01 1982 1985
PF-16BTC 3 200 A374-01 6PF-16BT2G 1982 1985
PF-16BTD 3 200 A194-10 PF-16BT2G 1986 1995
PF-16BTE 3 200 A198-04 6PF-16BT2G 1986 1995
200 A789-10 PF-16BT2F
PF-16BTF 3 1992 1995
400 A789-20 PF-16BT4F
PF-16BTG 3 200 A1031-02 PF-16BT2G 1996 2005
PF-16BTH 3 200 A1035-02 6PF-16BT2G 1996 2005
200 PFB-403S PF-16BT2G
PF-16BTS 3 1982 1985
400 ー PF-16BT4G
PFS-16BTD 3 200 A307-09 PFS-16BT2D A1612-01 1988 2005
WP-16A 1 100 WP-16AS1D C945-01 1953 1981
100 C298-01 WP-16AS1D C945-01
WP-16ASA 1 1982 2005
Outdoor 200 C298-02 WP-16AS2D C945-02
Type WP-16ATA 3 200 C260-01 WP-16AT2D C948-01 1982 2005
WP-16ATC 3 200 C348-01 6WP-16AT2D 1982 2005
WP-16B 1 100 WP-16BS1G C939-01 1953 1981

44
Model Development Table Pressure Fans

Sales period
Impeller Number Sales
diameter Type Product model of phases Voltage Frequency Assembly drawing Existing model Assembly drawing Sales launch year termination year 1950s 1960s 1970s 1980s 1990s 2000s 2010s
200 C289-01 WP-16BS1G C939-01
WP-16BSA 1 1982 2005
100 C289-02 WP-16BS2G C939-02
Outdoor 200 C477-01 6WP-16BS1G C940-01
40cm Type WP-16BSC 1 1982 2005
200 C477-02 6WP-16BS2G C940-02
WP-16BTA 3 200 C265-01 WP-16BT2G C942-01 1982 2005
WP-16BTC 3 200 C255-01 6WP-16BT2G C943-01 1982 2005
100 D-23711 PF-18AS1A A1632-01
1
PF-18A 200 D-23711 PF-18AS2A A1632-02 1953 1981
3 200 D-23715 PF-18AT2A A1633-01
100 PFA-451A PF-18AS1A A1632-01
PF-18ASA 1 1982 2005
200 PFA-452A PF-18AS2A A1632-02
200 PFA-453A PF-18AT2A A1633-01
Standard PF-18ATA 3 1982 2005
Type 400 PF-18AT4A A1633-02
100 D-23709 PF-18BS1A
1
PF-18B 200 D-23709 PF-18BS2A 1953 1981
45cm 3 200 D-23702 PF-18BT2A
100 PFB-451A PF-18BS1A
PF-18BSA 1 1982 2005
200 PFB-452A PF-18BS2A
PF-18BTA 3 200 PFB-453A PF-18BT2A 1982 2005
WP-18A 3 200 WP-18AT2A C981-01 1953 1981
WP-18ATA 3 200 C475-01 WP-18AT2A C981-01 1982 2005
Outdoor WP-18B 3 200 WP-18BT2A C978-01 1953 1981
Type C249-01
100 WP-18BA1A C978-01
WP-18BSA 1 1982 2005
200 C249-02 WP-18BS2A C978-02
WP-18BTA 3 200 C282-01 WP-18BT2A C978-01 1982 2005
100 D-23933 PF-20AS1A A1660-01
1
PF-20A 200 D-23933 PF-20AS2A A1660-02 1953 1981
3 200 D-23688 PF-20AT2A
100 PFA-501A PF-20AS1A A1660-01
PF-20ASA 1 1982 2005
200 PFA-502A PF-20AS2A A1660-02
PF-20ASS 1 200 A1678-02 PF-20AS2A A1660-02 2007 2007
200 A1332-01 PF-20AT2A
PF-20ATA 3 1982 2005
400 ー PF-20AT4A
PF-20ATS 3 200 A676-01 PF-20AT2A 1990 2005
Standard
Type 100 D-23909 PF-20BS1G
1
PF-20B 200 D-23909 PF-20BS2G 1953 1981
3 200 D-23694 PF-20BT2G
100 PFB-501A PF-20BS1G
PF-20BSA 1 1982 2005
200 PFB-502A PF-20BS2G
50cm 200 A428-02 PF-20BT2G
PF-20BTA 3 1982 2005
400 A428-03 PF-20BT4G
200 A518-01 PF-20BT2G
PF-20BTS 3 50 A518-04 1988 2005
400 PF-20BT4G
60 A518-07
WP-20A 1 100 WP-20AS1A C1006-01 1953 1981
100 C383-01 WP-20AS1A C1006-01
WP-20ASA 1 1982 2005
200 C383-02 WP-20AS2A C1006-02
WP-20ATA 3 200 C275-01 WP-20AT2A C1007-01 1982 2005
Outdoor WP-20B 3 200 PFB-301S-01 WP-20BT2G C944-01 1953 1981
Type C235-01
100 WP-20BS1G C995-01
WP-20BSA 1 1982 2005
200 C235-02 WP-20BS2G C995-02
WP-20BTA 3 200 C428-02 WP-20BT2G C944-01 1982 2005
50 C535-08
8WP-20BTA 3 200 WP-20BT2G C944-01 1995 2005
60 C535-07
PF-24A 3 200 D-23588 1953 1981
PF-24ATA 3 200 A575-01 PF-24AT2G A1674-01 1982
2005
PF-24ATB 3 200 PFA-603B 1982
50 A322-01 8PF-24AT2G A1673-01
200
60 A322-02 8PF-24AT2G A1674-01
8PF-24A 3 1988 2005
50 A322-12
400 8PF-24AT4G
60 ー A1674-03
Standard
60cm Type PF-24B 50 A519-01
3 200 1953 1981
60 A519-03 PF-24BT2G
200 A344-01
PF-24BTA 3 1982 2005
400 A428-02 PF-24BT4G
200 A334-02 PF-24BT2G
PF-24BTB 3 1982 2005
400 50 A334-03 PF-24BT4G
200 50 A343-01
8PF-24B 3 8PF-24BT2G 1988 2005
200 60 A343-02

45
Pressure Fans Model Development Table

Sales period
Impeller Number Sales
diameter Type Product model of phases Voltage Frequency Assembly drawing Existing model Assembly drawing Sales launch year termination year 1950s 1960s 1970s 1980s 1990s 2000s 2010s
50 C294-01
WP-24A 3 200 WP-24AT2G C1010-01 1953 1981
60 C294-02
50 C295-01
8WP-24A 3 200 8WP-24AT2G C1011-01 1989 2005
60 C295-02
WP-24ATA 3 200 WPA-603A
WP-24AT2G C1010-01 1982 2005
Outdoor WP-24ATB 3 200 50 WPA-603B
60cm Type 50 C237-01
WP-24B 3 200 WP-24BT2G C1008-01 1953 1981
60 C237-02
50 C281-03
8WP-24B 3 200 8WP-24BT2G C1011-01 1988 2005
60 C281-04
WP-24BTA 3 200 C323-01 WP-24BT2G C1008-01 1982 2005
8WP-24BTA 3 200 8WPB-603A 8WP-24BTG C1009-05 1982 2005
WP-24BTB 3 200 WPB-603B WP-24BT2G C1008-01 1982 2005
50 A398-01 A1689-01
PF-30A 3 200 PF-30AT2 1953 2005
60 A398-02 A1689-02
50 A381-01 A1697-01
8PF-30A 3 200 8PF-30AT2 1988 2005
Standard 60 A381-02 A1697-02
Type 50 A454-01
PF-30B 3 200 PF-30BT2 1953 2005
60 A454-02
50 A400-01
8PF-30B 3 200 8PF-30BT2 1988 2005
75cm 60 A400-02 A1696-02
50 C233-01 C1043-01
WP-30A 3 200 1953 2005
60 C233-02 WP-30AT2 C1043-02
8WP-30A 3 200 60 C287-13 1988 2005
Outdoor
Type WP-30B 50 C262-01 C1040-01
3 200 WP-30BT2 1953 2005
60 C262-02 C1040-02
50
8WP-30B 3 200 WP-30BT2G 1988 2005
60 C287-13
50 A521-01 A1690-01
PF-36A 3 200 PF-36AT2 1953 2005
60 A521-02 A1690-02
50 A392-01 A1699-01
8PF-36A 3 200 8PF-36AT2 1988 2005
Standard 60 A392-02 A1699-02
Type 50 A345-01
PF-36B 3 200 PF-36BT2G 1953 2005
60 A345-02
50 A348-01 A1698-01
8PF-36B 3 200 8PF-36BT2 1988 2005
60 A348-02 A1698-02
90cm
50 C363-01 C1044-01
WP-36A 3 200 1953 2005
60 C363-02 C1044-02
WP-36AT2
50 C1044-01
8WP-36A 3 200 1953 2005
Outdoor 60 C1044-02
Type 50 C234-01
WP-36B 3 200 1953 2005
60 C234-02
WP-36BT2G
50 C-WP90-18C-1
8WP-36B 3 200 1988 2005
60
50 A508-01 A1691-01
200 PF-42AT2
60 A508-03 A1691-02
PF-42A 3 1953 2005
Standard 50 A508-04
Type 400 PF-42AT4
60 A508-23
50 A328-01
105cm PF-42B 3 200 PF-42BT2G 1953 2005
60 A328-02
50 C248-01 C1045-01
WP-42A 3 200 WP-42AT2 1953 2005
Outdoor 60 C248-02 C1045-02
Type 50 C240-01
WP-42B 3 200 WP-42BT2G 1953 2005
60 C240-02
50 A406-03 A406-03
PF-48A 3 200 PF-48A 1953 2005
Standard 60 A406-04 A406-04
Type 50 A458-03 A458-03
PF-48B 3 200 PF-48B 1953 2005
60 A458-04 A458-04
120cm
50 C256-01 C256-01
WP-48A 3 200 WP-48A 1953 2005
Outdoor 60 C256-02 C256-02
Type 50 C230-01 C230-01
WP-48B 3 200 WP-48B 1953 2005
60 C230-02 C230-02

46
MEMO
TERAL INC.
Head Office 230, Moriwake, Miyuki-cyo, Fukuyama-city, Hiroshima, 720-0003, Japan
Tel.+81-84-955-1111 Fax.+81-84-955-5777
www.teral.net

Teral Asia Limited


Room 1001,10/F, Olympia Plaza, 255 King's Road, North Point, Hong Kong
Tel.+852-2571-0935 Fax.+852-2571-0619
TERAL THAI CO.,LTD.
150 Moo 16 Udomsorayuth Rd., T.Bangkrasan, A.Bangpa-In, Ayutthaya 13160 Thailand
Tel.+66-3535-2148-9 Fax.+66-3535-2150
TERAL TRADING & SERVICE CO.,LTD.
150 Moo 16 Udomsorayuth Rd., T.Bangkrasan, A.Bangpa-In, Ayutthaya 13160 Thailand
Tel.+66-3535-2145-7 Fax.+66-3535-8549
Teral Malaysia Sdn.Bhd.
10, Jalan SS13/6A, Subang Jaya Industrial Estate, 47500, Subang Jaya, Selangor D.E, Malaysia
Tel.+60-3-5611 5775 Fax.+60-3-5612 5775
PT.Teral Indonesia Pumps and Fans
Jalan BSD Sektor XI Taman Tekno, Block G3 No.8, Setu Tangerang Selatan, Banten, Indonesia 15314
Tel.+62-21-29665778 Fax.+62-21-75673913
Teral Vietnam Limited Liability Company
9th Floor, LADECO Building, No. 266 Doi Can Street, Lieu Giai Ward,Ba Dinh District, Hanoi City, Vietnam
Tel.+84-24-393-52-790 Fax.+84-24-393-52-289
Teral General Machine (Shanghai) Co.,Ltd.
No.285, Yuan Qu Road(N), Bei Qiao, Min Hang District, Shanghai 201109, China
Tel.+86-21-6490-9128 Fax.+86-21-6490-9126
Teral-Aerotech Fans Private Ltd.
Plot No.188-189, Ecotech Extension-1, Surajpur Kasna Road, Greater Noida-201306, Uttar Pradesh, India
Tel.+91-9810162210, +91-9310162210
Teral Middle East F.Z.C.
1806-002, 18th floor, BB1, Mazaya Business Avenue, JLT, Dubai, UAE. PO Box 414781
Tel.+971-4369 9039
Teral Pumps & Fans North America Ltd.
Suite # 197, 800-15355 24 Ave Surrey, B.C., CANADA V4A 2H9
Tel.+1-604-839-1008

Please note that product specifications are subject to change for improvement without prior notice.

E-CAT-F-PF-02-B