Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

Code

Sl No DSR Description of Item Unit Qty Rate Amount in INR


2016
1 2.6 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth,
1.5 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
All Kinds of Soil Cum 373.00 138.55 51,677.29

2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,


sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m.
Cum 235.00 138.33 32,506.38

3 16.79 Providing, laying, spreading and compacting graded stone


aggregate (size range 53 mm to 0.075 mm ) in horizontal layers of
max. thickness of 200mm and compacted thoroughly with the use of
sand so as to achieve min 95 percent of the modified Proctor
maximum dry density/ 85% relative density, whichever is more, as
per IS: 1498 specification including premixing the material with
water at OMC in for all leads & lifts, laying in uniform layers with
suitable equipment such as trench compactor, mechanical tamper,
rammer, plate vibrator etc. complete as per specifications and
directions of Engineer-in-Charge Cum 75.00 1,141.80 85,635.00

4 4.1.3 Providing and laying in position cement concrete of specified grade


excluding the cost of centering and shuttering - All work up to plinth
level :
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size). Cum 7.70 6030.15 46,432.12

5 5.9 Centering and shuttering including strutting, propping etc. and


removal of form for.
a 5.9.1 Foundations, footings, bases of columns, etc. forma ss concrete. Sqm 26.80 213.35 5,717.65

b 5.9.2 Walls (any thickness) including attached pilasters, butteresses,


plinth and string courses etc. Sqm 224.00 416.46 93,287.04

c 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 276.00 377.19 104,104.44

d 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 192.40 514.64 99,015.77

e 5.9.8 Spiral staircases (including landing) Sqm 64.00 419.54 26,850.56

f 5.9.3 Arches, domes, vaults up to 6 m span Sqm 87.60 464.53 40,692.83

g 5.9.10 Extra for arches, domes, vaults exceeding 6 m span Sqm 83.50 496.98 41,497.83

h 5.9.14 Extra for shuttering in circular work (20% of respective centering


and shuttering items) Sqm 784.00 537.87 421,687.73

6 5.1 Providing and fixing tie bolt, spring coil and plastic cone in wall
shuttering complete as per the direction of Engineer-in-charge.
20 mm dia.& 225 mm length Set 521.00 179.91 93,730.51

7 22.4 Providing and Placing in position suitable PVC water stops


conforming to IS:12200 for construction/ expansion joints between
two RCC members and fixed to the reinforcement with binding wire
before pouring concrete etc. complete :
22.4.1 Serrated with central bulb (225 mm wide, 8-11 mm thick) Meter 225.00 279.57 62,902.13

8 5.11 Extra for additional height in centering, shuttering where ever


required with adequate bracing, propping etc. including cost of de-
shuttering and decentering at all levels, over a height of 3.5 m, for
every additional height of 1 metre or part thereof (Plan area to be
measured).
5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area
to be measured). Sqm 564.00 188.65 106,398.60

9 5.14 Providing, hoisting and fixing up to floor five level precast


reinforced cement concrete in Steps, including setting in cement
mortar 1:3 (1 cement : 3 coarse sand), cost of required centering,
shuttering and finishing with neat cement punning on exposed
surfaces but excluding the cost of reinforcement, with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm
nominal size). Cum 3.00 11578.60 34,735.80
10 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete.
5.22.6 Thermo-Mechanically Treated bars Kg 27216.00 62.26 1,694,468.16

11 5.33 & Providing and laying in position ready mixed M-35 grade concrete
5.34.2 for reinforced cement concrete work, using cement content as per
approved design mix, manufactured in fully automatic batching plant
and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work, including
pumping of R.M.C. from transit mixer to site of laying , excluding the
cost of centering, shuttering finishing and reinforcement, including
cost of admixtures in recommended proportions as per IS : 9103 to
accelerate/ retard setting of concrete, improve workability without
impairing strength and durability as per direction of the Engineer - in
- charge.

Cum 123.70 8127.90 1,005,421.23

12 9.50 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of
weight not less than 7.75 Kg per sqm to window frames etc.
including 62x19 mm beading of second class teak wood and priming
coat with approved steel primer all complete.
Sqm 1.10 1159.40 1,275.34

13 10.25 Steel work welded in built up sections / framed work, including


cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and
similar works Sqm 71.30 2060.30 146,899.39

14 13.16 6 mm cement plaster of mix :


13.16.1 1:3 (1 cement : 3 fine sand) Sqm 688.00 158.18 108,827.84

15 13.18 Neat cement punning. Sqm 203.30 46.86 9,526.64

16 13.21 Extra for providing and mixing water proofing material in cement Per per bag of 50kg
bag of plaster work in proportion recommended by the Cement used in
manufacturers the mix 58.00 55.39 3,212.33

17 13.22 Extra for plastering exterior walls of height more than 10 m from
ground level for every additional height of 3 m or part Sqm 288.90 44.72 12,918.16

18 13.44 Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) Sqm 688.00 64.68 44,499.84

19 13.52 Finishing with Epoxy paint (two or more coats) at all locations
prepared and applied as per manufacturer's specifications including
appropriate priming coat, preparation of surface, etc. complete.
13.52.1 on steel works Sqm 72.40 134.75 9,755.90

20 19.19.4 Providing and fixing in position pre-cast R.C.C. manhole cover and
frame of required shape and approved quality E H D- 35

19.19.4.1 Circular shape 560 mm internal dia Each 1.00 1820.72 1,820.72

21 Providing and fixing 600 mm long MS hot dip galvanized puddle


flange fabricated out of 6 mm thick MS plates of suitable size and
IS:1239 heavy class pipes properly fixed in walls & top slab of tanks.
The entire fittings shall be hot dipped galvanized after fabrication.
Length shall be minimum 600 mm or wall thickness plus 200 mm on
either side (which ever is more).

100 mm dia (Screwed ends) Each 2.00 2000.00 4,000.00


150 mm dia (Screwed ends) Each 2.00 2500.00 5,000.00

22 19.16 Providing orange colour safety foot rest of minimum 6 mm thick


plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as 165
mm with minimum 112 mm space between protruded legs having 2
mm tread on top surface by ribbing or chequering besides
necessary and adequate anchoring projections on tail length on 138
mm as per standard drawing and suitable to with stand the bend
test and chemical resistance test as per specifications and having
manufacture’s permanent identification mark to be visible even after
fixing,including fixing in manholes with 30x20x15 cm cement
concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
Each 16.00 360.69 5,771.04
Total 4,400,268

You might also like