GENERAL NOTES:

1.ALL DIMENSIONS ARE IN FEET AND INCHES.ONLY WRITTEN DIMENSIONS HAS


TO BE FOLLOWED.
A B C A B C
2.GRADE OF CONCRETE SHALL BE M20 WITH MINIMUM CEMENT CONTENT OF
300kg/Cu.m.
3.GRADE OF STEEL SHALL BE Fe 415.
4.THE NET SAFE BEARING CAPACITY OF THE SOIL CONSIDERED FOR DESIGN AT
A DEPTH OF 2.5M FROM EXISTING GROUND LEVEL IS 15T/sq.m.
5.FOUNDATIONS ARE DESIGNED FOR G+3 STOREY WITHOUT CONSIDERING
EARTHQUAKE FORCES.
7 7
C2 C1

F1 F1
F3

6 6
C1

5 5
F1 C1 C3

F2 F3

4 4
C2 C3 C1

F1
F2 F3

3 3
C1

2 F1 2
C2 C3

F2 F3

1 1
C2 C2 C1

F1 F1
F2

LAYOUT OF FOOTINGS LAYOUT OF COLUMNS

SCHEDULE OF COLUMNS

TYPICAL PLAN DETAILS OF FOOTING S.No., COLUMN ID LENGTH BREADTH CORNER MIDDLE MIDDLE TIES
N.G.L "L1" "B1" R/F R/F R/F R/F
1) COLUMN C1 1'0" 0'9" Y16-4 Nos., Y12-4 Nos., - Y8@7"
2) COLUMN C2 1'0" 0'9" Y16-4 Nos., Y16-2 Nos., Y12-2 Nos., Y8@7"
3) COLUMN C3 1'6" 0'9" Y16-8 Nos., - - Y8@7"
OWNER:
SCHEDULE OF FOOTINGS MR.BALAJI,VANDAVASI-KANCHIPURAM.
DEPTH R/F ALONG "L" R/F ALONG "B" CONSULTANT:
S.No., FOOTING ID LENGTH BREADTH
"L" "B" D1 D2 BOT., TOP BOT., TOP M/s.J'STRUC CONSULTING ENGINEERS.
1) FOOTING F1 6'0" 6'0" 1'0" 1'6" Y12@6" Y10@6" Y12@6" Y10@6" PROJECT:
2) FOOTING F2 7'0" 7'0" 1'0" 2'0" Y12@5" Y10@6" Y12@5" Y10@6" CONSTRUCTION OF G+2 RESIDENTIAL BUILDING.
3) FOOTING F3 7'0" 7'0" 1'0" 2'0" Y16@5" Y10@6" Y16@5" Y10@6" DRAWING TITLE:
TYPICAL SECTION DETAILS OF FOOTING LAYOUT&RC DETAILS OF FOOTINGS AND COLUMNS.