Laser Exposure System: Cleaning The Dustproof Glass
Laser Exposure System: Cleaning The Dustproof Glass
4-126
Laser Exposure System 2) Insert the Dustproof Glass cleaning tool [1] into a cleaning hole [2] and clean the Dustproof
Glass on the top side.
■■Preparation • Push the Dustproof Glass cleaning tool until it stops, and then pull it out.
• Push and pull the tool at least one time.
1) Open the Front Cover.
2) Remove the Upper Front Cover (Refer to page 4-339).
3) Remove the Toner Container Replacement Unit Inner Cover (Refer to page 4-339). [2]
■■Procedure
1) Remove the Dustproof Glass cleaning tool [1] from the backside of the Toner Container
Replacement Unit Inner Cover.
[1]
[1]
F-4-138
3) Pull out the Dustproof Glass [1], and clean both sides of the Dustproof Glass with lint-free
paper [2] moistened with alcohol.
[2]
F-4-137
[1]
[1]
F-4-139
4-126
4
Parts Replacement and Cleaning > Laser Exposure System > Cleaning the Dustproof Glass > Procedure
4 Parts Replacement and Cleaning > Laser Exposure System > Removing the Laser Scanner Unit > Preparation
4-127
When the delivery system options are installed, be sure to disconnect them from the
[1]
host machine.
7-1) Removing the DADF Unit + Reader Unit (for copier model) (Refer to page 4-352).
7-2) Removing the Printer Upper Cover (for printer model) (Refer to page 4-358).
4-127
4
Parts Replacement and Cleaning > Laser Exposure System > Removing the Laser Scanner Unit > Preparation
4 Parts Replacement and Cleaning > Laser Exposure System > Removing the Laser Scanner Unit > Procedure
4-128
■■Procedure CAUTION:
The Small Gauge Coaxial Cable Connector [1] cannot be pulled out upward (in the
NOTE:
This procedure shows the steps to be taken in the case of Laser Scanner Unit (Y). direction toward the harness). Do not pull it upward or the cable will be broken.
Disassemble and assemble the Laser Scanner Units (M), (C), and (Bk) in the same
way.
[1]
[3]
x3
F-4-142
2) Pull the connector [1] and the tag [2] horizontally to disconnect the Small Gauge Coaxial
Cable Connector [3].
[2]
F-4-141
[3]
x2
[2]
[1]
F-4-143
4-128
4
Parts Replacement and Cleaning > Laser Exposure System > Removing the Laser Scanner Unit > Procedure
4 Parts Replacement and Cleaning > Laser Exposure System > Removing the Laser Scanner Unit > Procedure
4-129
3) Move the Laser Scanner Unit [1].
NOTE:
• 3 Stepped Screws [2]
The number of Wire Saddles differ depending on the Laser Scanner Units (Y), (M), (C),
• 3 Washers [3] and (Bk). Follow the instruction shown below.
• 3 Springs [4]
• 1 Guide [5] • In the cases of Laser Scanner Units (Y), (M), and (C), refer to step 4-1.
• In the case of Laser Scanner Unit (Bk), refer to step 4-2.
[2]
x3 [2] 4-1) Remove the Laser Scanner Unit (Y)/(M)/(C) [1].
[3] • 2 Wire Saddles [2]
[2]
• 1 Connector [3]
[3] [4]
[3]
[4]
[4] [3]
x2
[1]
[2]
[5] [1]
F-4-145
4-2) Remove the Laser Scanner Unit (Bk) [1].
• 1 Wire Saddle [2]
F-4-144 • 1 Connector [3]
[1]
[3] [2]
F-4-146
4-129
4
Parts Replacement and Cleaning > Laser Exposure System > Removing the Laser Scanner Unit > Procedure
4 Parts Replacement and Cleaning > Laser Exposure System > When Replacing the Laser Scanner Unit > Procedure
4-130
When Replacing the Laser Scanner Unit
■■Preparation
1) Remove the Buffer Path Unit (Refer to page 4-361).
2) Remove the DADF Unit and the Reader Unit (Refer to page 4-352).
3) Remove the Laser Scanner Unit (Refer to page 4-127).
■■Procedure
Before removing the Laser Scanner Unit
1) Adjust the initial position of the Skew Correction Motor.
(COPIER > FUNCTION > LASER > LD-ADJ-Y/M/C)
4-130
4