Fiber Photoelectric
Description
Sensors
FS-T22(P)
One-touch calibration
FS2/FS-T22 Series The FS-T22(P) can be adjusted with the simple press of a button,
making calibration during product changeover easy. This unique
calibration system ensures optimum detection every time.
Features Convenient setup
● 5 amplifiers and over 40 fiber units to All FS-T22(P) settings can be made by the operator or through
choose from external equipment. This is especially convenient when the amplifier is
● One-touch calibration (FS-T22) inaccessible.
● Detect objects as small as 0.09-mm Detection in unstable conditions
0.003" dia. Critical detection can be made even in unstable conditions and the
● High-speed response as short as 50 µs FS-T22 reliably detects any target without detecting the background.
● Accurate detection in unstable condi- FS-T22(P)
One-touch Calibration:
Built-in Timer:
tions A 40 ms ON-/OFF-delay Sensitivity can be adjusted
timer is included in the simply with the press of a
compact design. button.
Calibration Indicator:
Operation Mode Selector Switch:
LED flashes when
Detecting Distance Switches between LIGHT-ON and calibration is complete.
DARK-ON mode.
Thrubeam – Up to 1100 mm (43.31") Lock Switch:
Quick Release Lever: Prevents accidental
Easily connects or changes to settings.
disconnects a fiber unit. Stability Indicator:
Diffuse-reflective – Up to 130 mm (5.12")
LED is ON during stable
detection. Flashes to
indicate a calibration error.
Definite-reflective – Up to 6 mm (0.24")
FS2 Series
High-intensity beam (FS2-62(P))
The FS2-62(P) has twice the detecting distance of conventional
amplifiers. The beam penetrates dusty environments to reliably detect
targets.
Alarm buzzer
All FS2 Series amplifiers come equipped with an alarm buzzer that can
be configured to sound when a target is detected or when there is
insufficient light.
FS2 Series
Built-in Timer:
ON-delay, OFF-delay or Timer
OFF mode can be selected.
88
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
7
6
5
4
3
12
0
Detection of register mark on
Detection of IC packs in heat
printed paper
testing
Note: (X) indicates a model with a special “X” version for use only with the FS-T22(P) amplifier.
89
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Selection Chart
Fiber unit
Smallest Minimum Weight
Type Shape Detecting distance detectable bend Features (Approx.)
Model
object radius
250 mm 9.84"
Built-in 130 mm 5.12" ø0.3 mm R25 mm Narrow-beam
Lens ø0.02" type 11g FU-36X
R0.98"
35 mm 1.38"
100 mm 3.94"
3g FU-59
Thrubeam
90 mm 3.54"
ø0.1 mm R10 mm
Thin-sleeve 45 mm 1.77" ø0.004" R0.39 Thin-sleeve 10g FU-75F
12 mm 0.47" Free-
cut
100 mm 3.94"
R25 mm
Space-saving
50 mm 1.97"
ø0.2 mm R0.98" 17g FU-34
ø0.008" sleeve
Free-
14 mm 0.55" cut
Side-view
30 mm 1.18" R25 mm
ø0.9 mm Space-saving,
20 mm 0.79" R0.98" 5g FU-32
ø0.04" thin-sleeve
Free-
5 mm 0.20" cut
ø0.01 mm
80 mm 3.15" ø0.0004"
ø0.03 mm Suitable for
R25 mm
55 mm 2.17" ø0.001" positioning
R0.98"
ø0.1 mm 18g FU-25
Diffuse-reflective
16 mm 0.63" Free-
Coaxial ø0.004" cut
6 mm 0.24" ø0.3 mm
ø0.02"
ø0.01 mm
ø0.0004" R25 mm Coaxial fiber
35 mm 1.38"
R0.98" 0.4 mm 0.16"
ø0.03 mm
17 mm 0.67" ø0.001" spot diameter 6g FU-35FA
Free-
5 mm 0.20" cut when used with
ø0.1 mm F-2HA.
ø0.004"
ø0.01 mm 7g FU-48
30 mm 1.18" ø0.0004" R4 mm
R0.16"
20 mm 0.79"
Free-
4 mm 0.16" ø0.8 cut
ø0.03 mm" 8g FU-68
ToughFlex High-flex fiber
ø0.01 mm R4 mm
15 mm 0.59" ø0.0004" R0.16"
3g FU-49X
8 mm 0.31"
R4 mm R0.16"
3mm 0.12" ø0.3 mm
ø0.02" Free- 3g FU-69
cut
When using the FS2-62(P). When using the FS2-60(P)/FS-T22(P). When using the FS2-65(P). When using the FS2-60G.
Note: Models with an "X" in the name can only be used with the FS-T22(P) amplifier.
90
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Fiber unit
Smallest Mimimum Weight
Type Shape Detecting distance detectable bend Features (Approx.)
Model
object radius
ø0.01 mm Flush-mounting
ø0.0004" R25 mm type 8g FU-43
36 mm 1.42"
R0.98"
18mm 0.71" Screw type FU-63
ø0.3 mm Free-
ø0.02" cut 10g
8 mm 0.31" Flat type FU-63T
ø0.01 mm
25 mm 0.98" ø0.0004"
Thin-sleeve
20 mm 0.79" ø0.1 mm R10 mm 2g FU-39*
ø0.004" R0.39" Sleeve
Diffuse-reflective
7 mm 0.28" ø0.1 mm
ø0.004"
ø0.01 mm High-flex fiber, 4g FU-45X
8mm 0.31" ø0.0004" flush-mounting type
R4 mm
4 mm 0.16" ø0.015 mm R0.16" High-flex fiber,
ø0.0006" 5g FU-65X
screw type
8mm 0.31" ø0.01 mm
ø0.0004"
Narrow- 7 mm 0.28" R25 mm Small beam spot
beam 4g FU-22X
ø0.03 mm R0.98"
2 mm 0.08" ø0.001"
20 mm 0.79" R25 mm
ø0.3 mm R0.98" Space-saving
Side-view 10 mm 0.39" ø0.01" 10g FU-33
Free-
3 mm 0.12" cut
3 mm 0.12"
ø0.01 mm 6g FU-37
Definite-reflective
Heat- ø0.01 mm
resistant 100 mm 3.94" ø0.0004"
150 mm 5.91"
ø0.3 mm 300°C resistance
R25 mm 66g FU-84C
90 mm 3.54" ø0.01" Glass fiber with
R0.98"
sleeve
35 mm 1.38"
320 mm 12.60"
R25 mm
160 mm ø0.3 mm R0.98"
Heat- 105°C resistance
6.30" ø0.01" Free- 22g FU-86
resistant Plastic fiber
70 mm 2.76" cut
27 mm 1.06"
Thrubeam
200 mm 7.87"
R35 mm
ø0.3 mm 1.38" 180°C resistance
150 mm ø0.01" Plastic fiber 36g FU-88
5.91" Free-
40 mm 1.57" cut
1100 mm 43.31"
When using the FS2-62(P). When using the FS2-60(P)/FS-T22(P). When using the FS2-65(P). When using the FS2-60G.
Attachment
Type Configuration Features Applicable fiber units Model
92
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Connections
FS-T22 FS-T22P
NPN Brown PNP Brown
100 mA max.
Black Black
Load Load
50 mA max. 12 to 24 VDC 12 to 24 VDC
Orange
Load Load
Orange
Blue Blue
Pink Pink
Input for external Input for external
calibration calibration
FS2-60/FS2-62/FS2-65/FS2-60G FS2-60P/FS2-62P/FS2-65P
NPN PNP
Brown Brown
100 mA max.
Black Black Load
Load
50 mA max. 12 to 24 VDC 12 to 24 VDC
Orange Orange
Load Load
Blue Blue
93
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Input/Output Circuits
FS-T22 Output circuit
NPN PNP
Brown Brown
Load
Black
Load
Short-
circuit (Control output) Short-
12 to 24 VDC
Main circuit
Main circuit
tion protec-
(Alarm output) (Control output)
circuit tion
circuit Orange
Load
Blue (Alarm output)
Load
Pink Blue
(External calibration)
Pink
(External calibration)
FS-T22(P) Input circuit
Input circuit for external calibration
12 to 24 VDC
1.8 kΩ
470 Ω
1.8 kΩ
Yellow
Short-
Load
12 to 24 VDC circuit
Main circuit
Black
Main circuit
Black 12 to 24 VDC
(Control output) protec-
Short- (Control output)
tion
circuit Orange circuit Orange
Load
protec- (Alarm output) (Alarm output)
Load
tion
circuit
Blue Blue
Adjustment
FS-T22
Thrubeam type/ Diffuse-reflective type
Setting the sensitivity Setting to maximum sensitivity
1. With a target in place, press the SET When a reflective sensor is used for long distance
pushbutton. The yellow LED lights. detection or a thrubeam sensor is used for detection in an
set unstable environment, follow the procedure given below
to set the sensitivity to maximum.
1. With (thrubeam), or without (reflective) a
2. With no target, press the SET pushbutton.
target in place, hold the SET pushbutton
The yellow LED turns off. Setting is
set complete. If sensitivity cannot be set
set down for 3 seconds. When the yellow LED
starts flashing, setting is complete. With a
because the received light quantity with and
reflective sensor, if there is a background
without a target is too small, the green LED
object, set the sensitivity to the highest
flashes for approx. 2 seconds.
setting that will not detect the background
set
3. Check sensor operation. object.
set
2. Check sensor operation.
94
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Precautions
Stability indicator Sensitivity setting protection
When setting the sensitivity, it flashes to indicate the To prevent the sensitivity from being accidentally
sensitivity setting has been rejected due to small excess changed, set the sensitivity setting protector switch to
gain and that the current sensitivity remains valid. LOCK. The sensitivity will not change even if the SET
pushbutton is pressed.
[Note]
External sensitivity Brown This function does not prevent changes in sensitivity
+V
adjustment input externally, or operation mode or timer mode
The sensitivity can be set changes.
from external device, Blue 0V
rather than using the SET Pink
pushbutton on the Contact or Self-diagnosis
solid-state input
amplifier unit. Use an (NPN only) • If the sensitivity cannot be set, the green LED flashes
input signal of 40 ms or and the alarm signal is output for 2 seconds.
more.
• If, after the sensitivity has been set, the received light
quantity falls below a specified level due to dirt on the
lens or misalignment of the optical axis, the alarm
output is triggered.
FS2
Thrubeam type Diffuse-reflective type
DARK-ON mode (When LIGHT-ON mode is specified, LIGHT-ON mode (When DARK-ON mode is specified,
refer to words in parentheses.) refer to words in parentheses.)
1. With a target in place, turn the trimmer 1. With no target, turn the trimmer clockwise
clockwise until the red LED indicator turns until the red LED indicator lights (turns off).
off (lights). – Point A – Point A
A A
B 2. With no target, turn the trimmer counter- B 2. With a target in place, turn the trimmer
clockwise until the green LED lights (turns counterclockwise until the green LED turns
off). – Point B off (lights). – Point B
A A
Optimal 3. Set the trimmer midway between points A Optimal 3. Set the trimmer midway between points A
B position B position
and B. Confirm sensor operation. and B. Confirm sensor operation.
A A
Precautions
Adjustment with alarm buzzer Adjustment with the trimmer
• The output indicator operates in conjunction with a built- cap
Trimmer cap
in buzzer when the alarm selector switch on the top of • Adjust the trimmer with the (detachable)
the amplifier unit is set to the OUT position, facilitating trimmer cap or with a
adjustment. screwdriver.
• When the alarm selector switch is set to the STB
position, the alarm buzzer sounds when light quantity is
reduced by an accumulation of dust or dirt on the lens
surface, or when the optical axis is out of alignment
(through-beam sensor).
• Set the alarm switch to the OFF position to deactivate
the buzzer function.
95
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Timing Chart
LIGHT-ON mode DARK-ON mode
1 2 3
1 2 3
Stable operating level
Stable operating level Operating level
Operating level
ON
Red LED
ON OFF
Red LED
OFF
ON
Green LED
ON OFF
Green LED
OFF
ON
Control output
ON OFF
Control output
OFF
ON Reset
Reset Alarm output
ON OFF
Alarm output
OFF
• If the light quantity received by the receiver of the • If the light quantity is not restored to a stable level after
sensor drops from a stable level 1 to an unstable level detection of a target 2, the alarm output is triggered
2, the alarm output is triggered. when detecting a second target 3.
Amplifier
• When the external tuning input is not used, cut the pink
cable very short or connect it to the positive terminal of
the power supply.
96
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
97
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE
Dimensions CAD
38.5 31.2
1.52" 1.23"
0.12" 0.81" 18.7
3 17.3
20.5 0.74" 0.68"
ø0.13 5.5 3
0.52" 2 x ø3.2 0.22" 4.5 0.18" 0.12"
13.1 1.00" 0.11" 2.8 2 x ø3.2 ø0.13"
15.9 25.4 Spot facing: 8, 4(d) 25.4 1.00" mounting hole
0.63" 31 0.31, 0.16(d) 7.7 31
1.22" 0.30" 1.22"
Fiber unit
For dimensions of the fiber units, refer to the FS01 Series dimensions.