Fiber Photoelectric
Description
Sensors
FS-T22(P)
One-touch calibration
FS2/FS-T22 Series The FS-T22(P) can be adjusted with the simple press of a button,
making calibration during product changeover easy. This unique
calibration system ensures optimum detection every time.
Features Convenient setup
● 5 amplifiers and over 40 fiber units to All FS-T22(P) settings can be made by the operator or through
choose from external equipment. This is especially convenient when the amplifier is
● One-touch calibration (FS-T22) inaccessible.
● Detect objects as small as 0.09-mm Detection in unstable conditions
0.003" dia. Critical detection can be made even in unstable conditions and the
● High-speed response as short as 50 µs FS-T22 reliably detects any target without detecting the background.
● Accurate detection in unstable condi- FS-T22(P)
One-touch Calibration:
Built-in Timer:
tions A 40 ms ON-/OFF-delay Sensitivity can be adjusted
timer is included in the simply with the press of a
compact design. button.
Calibration Indicator:
Operation Mode Selector Switch:
LED flashes when
Detecting Distance Switches between LIGHT-ON and calibration is complete.
DARK-ON mode.
Thrubeam – Up to 1100 mm (43.31") Lock Switch:
Quick Release Lever: Prevents accidental
Easily connects or changes to settings.
disconnects a fiber unit. Stability Indicator:
Diffuse-reflective – Up to 130 mm (5.12")
LED is ON during stable
detection. Flashes to
indicate a calibration error.

Definite-reflective – Up to 6 mm (0.24")

FS2 Series
High-intensity beam (FS2-62(P))
The FS2-62(P) has twice the detecting distance of conventional
amplifiers. The beam penetrates dusty environments to reliably detect
targets.

High-speed response (FS2-65(P))


With a 50-µs response speed, the FS2-65(P) can handle almost any
application. This amplifier is ideally suited for detecting very small
targets, like ICs on a high-speed production line.
Versatility (FS2-60(P))
A combination of response speed, detecting distance and easy-to-use
functions makes the FS2-60(P) one of the most versatile amplifiers of
its kind. An unbeatable price/performance ratio makes this amplifier a
great deal.

Alarm buzzer
All FS2 Series amplifiers come equipped with an alarm buzzer that can
be configured to sound when a target is detected or when there is
insufficient light.
FS2 Series

Convenient Stability Indicator: Easy-to-mount Fiber Unit


Goes off if there is insufficient light Connector
intensity.
LIGHT-ON/DARK-ON
mode selector switch
Alarm Buzzer:
Calibration Trimmer:
Buzzer sounds when a target is
detected or when light intensity Minute sensitivity adjustments can
is insufficient. be made with this 8-turn trimmer.

Built-in Timer:
ON-delay, OFF-delay or Timer
OFF mode can be selected.

88
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Fiber Photoelectric Sensors FS2/FS-T22


Fiber Unit Selection Guide (major models only)
High-flex: FU-48, 68, 49X, 59, 79 Long-detecting distance: FU-6F, 66,
High-flex fiber units deliver long 5F, F-2+FU-7F/84C/86
service-life on moving production Fiber units for stable and accurate long
lines machinery. distance detection, even in harsh
environments.

Detection of targets in dusty,


Robotic arm position sensing oily, or steamy conditions

Focusing lens: FU-35FA + F-2HA, Heat-resistant: FU-81C, 82C, 83C, 84C


3HA, FU-22X Heat-resistant-free-cut: FU-85, 86, 87, 88
Focused-beam fiber units detect very Heat-resistant fiber units for stable
small targets in limited spaces. detection at up to 350°C.

7
6
5
4
3
12
0
Detection of register mark on
Detection of IC packs in heat
printed paper
testing

Narrow-beam: FU-22X, 36X Side-view: FU-32, 33, 34, F-1+FU-7F/


Focused-beam fiber units have a diffuse 84C/86
angle of only 10° and a beam spot one- Side-view fiber units provide mounting
sixth the diameter of conventional flexibility and detection in normally
focused- beam sensors. inaccessible areas.

Detection of lead of miniature tip


transistor Detection of connection pins

Definite-reflective: FU-37 Liquid-level-detection: FU-93, 94, 95


Definite-reflective fiber unit detects Liquid-level-detection fiber units are
targets of any color or finish and is simple to install and have easy-to-
useful for positioning control. Even a adjust high and low tolerance limits.
wafer can be detected. FU-93, 94 are Teflon®-sheathed.

Level control of lubricating or


Wafer detection hydraulic oils

Thin-sleeve: FU-45X, 65X, 75F Teflon®-sheathed: FU-91, 92


Fiber units with a thin-sleeve for Teflon®-sheathed fiber units can
detecting tiny targets in limited areas. function in harsh environments, like
7"
1.5 where water, oil and chemicals splash.
mm
40

Detection of IC on lead frame PCB detection during cleaning


process

Note: (X) indicates a model with a special “X” version for use only with the FS-T22(P) amplifier.

89
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

FS2/FS-T22 Fiber Photoelectric Sensors

Selection Chart
Fiber unit
Smallest Minimum Weight
Type Shape Detecting distance detectable bend Features (Approx.)
Model
object radius

320 mm 12.60" 19g FU-5F


Long-detecting
distance
Standard 160 mm ø0.3 mm R25 mm
6.30" 21g FU-7F
70mm 2.76" ø0.02" R0.98"
Free- Long-detecting 24g FU-73
27mm 1.06" cut distance, sleeve

250 mm 9.84"
Built-in 130 mm 5.12" ø0.3 mm R25 mm Narrow-beam
Lens ø0.02" type 11g FU-36X
R0.98"
35 mm 1.38"

100 mm 3.94"
3g FU-59
Thrubeam

ø0.1 mm R4 mm High-flex fiber


ToughFlex 50 mm 1.97" ø0.004" R0.16"
14 mm 0.55" Free- 6g FU-79
cut

90 mm 3.54"
ø0.1 mm R10 mm
Thin-sleeve 45 mm 1.77" ø0.004" R0.39 Thin-sleeve 10g FU-75F
12 mm 0.47" Free-
cut

100 mm 3.94"
R25 mm
Space-saving
50 mm 1.97"
ø0.2 mm R0.98" 17g FU-34
ø0.008" sleeve
Free-
14 mm 0.55" cut
Side-view
30 mm 1.18" R25 mm
ø0.9 mm Space-saving,
20 mm 0.79" R0.98" 5g FU-32
ø0.04" thin-sleeve
Free-
5 mm 0.20" cut

100 mm 3.94" ø0.01 mm


ø0.004" 21g FU-6F
R25 mm Long-detecting
Standard R0.98"
65 mm 2.56" distance
ø0.03 mm Free- 10g FU-66
ø0.001" cut
20 mm 0.79"
ø0.2 mm R25 mm
8 mm 0.31" ø0.008" R0.98" 4g FU-23X

ø0.01 mm
80 mm 3.15" ø0.0004"
ø0.03 mm Suitable for
R25 mm
55 mm 2.17" ø0.001" positioning
R0.98"
ø0.1 mm 18g FU-25
Diffuse-reflective

16 mm 0.63" Free-
Coaxial ø0.004" cut
6 mm 0.24" ø0.3 mm
ø0.02"
ø0.01 mm
ø0.0004" R25 mm Coaxial fiber
35 mm 1.38"
R0.98" 0.4 mm 0.16"
ø0.03 mm
17 mm 0.67" ø0.001" spot diameter 6g FU-35FA
Free-
5 mm 0.20" cut when used with
ø0.1 mm F-2HA.
ø0.004"

ø0.01 mm 7g FU-48
30 mm 1.18" ø0.0004" R4 mm
R0.16"
20 mm 0.79"
Free-
4 mm 0.16" ø0.8 cut
ø0.03 mm" 8g FU-68
ToughFlex High-flex fiber
ø0.01 mm R4 mm
15 mm 0.59" ø0.0004" R0.16"
3g FU-49X
8 mm 0.31"
R4 mm R0.16"
3mm 0.12" ø0.3 mm
ø0.02" Free- 3g FU-69
cut

When using the FS2-62(P). When using the FS2-60(P)/FS-T22(P). When using the FS2-65(P). When using the FS2-60G.
Note: Models with an "X" in the name can only be used with the FS-T22(P) amplifier.

90
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Fiber Photoelectric Sensors FS2/FS-T22

Fiber unit
Smallest Mimimum Weight
Type Shape Detecting distance detectable bend Features (Approx.)
Model
object radius
ø0.01 mm Flush-mounting
ø0.0004" R25 mm type 8g FU-43
36 mm 1.42"
R0.98"
18mm 0.71" Screw type FU-63
ø0.3 mm Free-
ø0.02" cut 10g
8 mm 0.31" Flat type FU-63T
ø0.01 mm
25 mm 0.98" ø0.0004"
Thin-sleeve
20 mm 0.79" ø0.1 mm R10 mm 2g FU-39*
ø0.004" R0.39" Sleeve
Diffuse-reflective

7 mm 0.28" ø0.1 mm
ø0.004"
ø0.01 mm High-flex fiber, 4g FU-45X
8mm 0.31" ø0.0004" flush-mounting type
R4 mm
4 mm 0.16" ø0.015 mm R0.16" High-flex fiber,
ø0.0006" 5g FU-65X
screw type
8mm 0.31" ø0.01 mm
ø0.0004"
Narrow- 7 mm 0.28" R25 mm Small beam spot
beam 4g FU-22X
ø0.03 mm R0.98"
2 mm 0.08" ø0.001"

20 mm 0.79" R25 mm
ø0.3 mm R0.98" Space-saving
Side-view 10 mm 0.39" ø0.01" 10g FU-33
Free-
3 mm 0.12" cut

3 mm 0.12"
ø0.01 mm 6g FU-37
Definite-reflective

3 mm 0.12" ø0.0004" Almost unaffected


R10 mm by target color,
Definite- 6 mm 0.24" R0.39" background.
reflective ø0.01 mm
ø0.0004" Free- FU-38
6 mm 0.24"
cut
5g
ø0.08 mm Almost unaffected by
0 ~ 4 mm 0 to 0.16" ø0.003" target color,
ø0.3 mm background. Side-by- FU-38V
2 ± 1.4 mm 0.08" ± 0.06" side detection available
ø0.01"
When using the FS2-62(P). When using the FS2-60(P)/FS-T22(P). When using the FS2-65(P). When using the FS2-60G.
Note: Models with an "X" in the name can only be used with the FS-T22(P) amplifier.
* These fiber units cannot be combined with the FS-T22(P) amplifier.

Heat-resistant & Oil-proof fiber unit


Smallest Minimum Weight
Type Shape Detecting distance detectable bend Features (Approx.)
Model
object radius
ø0.01 mm
60 mm 2.36" ø0.0004"
350°C resistance
40 mm 1.57" ø0.03 mm Glass fiber with
ø0.001" 24g FU-81C
sleeve
12 mm 0.47" ø0.1 mm
ø0.004" R25 mm
ø0.01 mm R0.98"
300°C resistance
70 mm 2.76" ø0.0004" Glass fiber with 29g FU-82C
ø0.03 mm sleeve
50 mm 1.97"
ø0.001"
14 mm 0.55" 300°C resistance
ø0.1 mm Glass fiber 23g FU-83C
ø0.004"
Diffuse-reflective

Heat- ø0.01 mm
resistant 100 mm 3.94" ø0.0004"

65 mm 2.56" ø0.03 mm R25 mm


ø0.001" R0.98" 105°C resistance 21g FU-85
20 mm 0.79" ø0.1 mm Free-
Plastic fiber
ø0.004" cut
8 mm 0.31" ø0.3 mm
ø0.01"
ø0.03 mm
70 mm 2.76" ø0.001" R35 mm
ø0.03 mm R1.38"
50 mm 1.97" 180°C resistance 33g FU-87
ø0.001" Free- Plastic fiber
cut
15 mm 0.59" ø0.3 mm
ø0.01"
ø0.01 mm
60 mm 2.36" ø0.0004" R40 mm
Oil-proof, R1.57"
ø0.03 mm Teflon®-fiber
chemical 50 mm 1.97"
ø0.001" 32g FU-91
proof Free-
15 mm 0.59" ø0.1 mm cut
ø0.004"
When using the FS2-62(P). When using the FS2-60(P)/FS-T22(P). When using the FS2-65(P). When using the FS2-60G.
Note: Models with an "X" in the name can only be used with the FS-T22(P) amplifier.
* These fiber units cannot be combined with the FS-T22(P) amplifier.
91
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

FS2/FS-T22 Fiber Photoelectric Sensors

Heat-resistant & Oil-proof fiber unit


Smallest Minimum Weight
Type Shape Detecting distance detectable bend Features (Approx.)
Model
object radius

150 mm 5.91"
ø0.3 mm 300°C resistance
R25 mm 66g FU-84C
90 mm 3.54" ø0.01" Glass fiber with
R0.98"
sleeve
35 mm 1.38"

320 mm 12.60"
R25 mm
160 mm ø0.3 mm R0.98"
Heat- 105°C resistance
6.30" ø0.01" Free- 22g FU-86
resistant Plastic fiber
70 mm 2.76" cut

27 mm 1.06"
Thrubeam

200 mm 7.87"
R35 mm
ø0.3 mm 1.38" 180°C resistance
150 mm ø0.01" Plastic fiber 36g FU-88
5.91" Free-
40 mm 1.57" cut

1100 mm 43.31"

600mm 23.62" ø0.9 mm


Teflon®-fiber 71g FU-92
ø0.04"
R40 mm
180 mm 7.09" R1.57"
Oil-proof,
chemical Free-
proof 350 mm 13.78" cut

200 mm 7.87" ø0.6 mm Teflon®-fiber


Side-view type 71g FU-96
ø0.02"
50mm 1.97"

When using the FS2-62(P). When using the FS2-60(P)/FS-T22(P). When using the FS2-65(P). When using the FS2-60G.

Attachment
Type Configuration Features Applicable fiber units Model

Side-view Space-saving, side-view type F-1


FU-7F, FU-84C, FU-86
Long-detecting
distance Greater detecting distance F-2

0.4 mm 0.16" beam spot diameter F-2HA


Focusing lens FU-35FA
Beam spot diameter: 4 mm 0.16"
Detecting distance: 19 ±2 mm0.75"± 0.08" F-3HA

FU-63, FU-66, FU-68 OP-6630


Protective tube Stainless-steel spiral tube
FU-7F, FU-73, FU-84C, FU-86 OP-6631

Type Side-view Long-detecting distance Focusing lens


Model F-1 F-2 F-2HA F-3HA
Fiber unit FU-7F FU-84C1. FU-861. FU-7F FU-84C FU-86 FU-35FA
FS-T22 (P) 220 8.66" — 220 8.66" 1100 43.31" — 1100 43.31" Center of Center of
FS2-62 (P) 400 15.75" 220 8.66" 400 15.74" 1800 70.86" 1500 59.06" 1800 70.86" detecting detecting
Detecting distance: distance:
distance FS2-60 (P) 220 8.66" 160 6.30" 220 8.66" 1100 43.31" 900 35.43" 1100 43.31" 7±1 19 ± 2
(mm) 0.28" ± 0.04" 0.75" ± 0.08"
FS2-65 (P) 70 2.76" 60 2.36" 70 2.76" 300 11.81" 240 9.45" 300 11.81"
FS2-60G 35 1.38" — 351.38" 150 5.91" — 150 5.91" — —
0.03 mm 0.1 mm
Smallest detectable
0.6 mm 0.02" dia. opaque material 0.9 mm 0.04" dia. opaque material 0.001" dia. 0.004" dia.
object
copper wire copper wire
1. To use the F-1 with the FU-84C or FU-86, specify the heat-resistant F-1 when ordering.

92
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Fiber Photoelectric Sensors FS2/FS-T22


Specifications
Amplifier
One-touch Ultra-long Long-detecting High-speed Color
Type
calibration detecting distance distance response differentiation
NPN FS-T22 FS2-62 FS2-60 FS2-65 FS2-60G
Mode
PNP FS-T22P FS2-62P FS2-60P FS2-65P —
Light source Red LED Red LED Red LED Red LED Green LED
Sensitivity adjustment Pushbutton 8-turn trimmer 8-turn trimmer 8-turn trimmer 8-turn trimmer
Response time 500 µs 500 µs 250 µs 50 µs 250 µs
Operation mode LIGHT-ON/DARK-ON (switch-selectable)
Output: Red LED,
Tuning: Yellow LED, Output: Red LED, Output: Red LED, Output: Red LED, Output: Red LED,
Indicators Stable operation and Stable operation: Stable operation: Stable operation: Stable operation:
sensitivity setting Green LED Green LED Green LED Green LED
error: Green LED
Timer mode ON-delay 40 ms/OFF-delay 40 ms/Timer OFF (switch-selectable)
Buzzer ON when control output turns ON/ Buzzer ON when alarm output turns ON/
Buzzer mode —
Buzzer OFF (switch-selectable)
Control NPN or PNP : 100 mA max. (40 V max.), Residual voltage: 1 V max.
Output
Alarm NPN or PNP : 50 mA max. (40 V max.), Residual voltage: 1 V max.
Protection circuit Reversed polarity, Overcurrent protection, Surge absorber
Power supply 12 to 24 VDC ±10% 12 to 24 VDC ±10% 12 to 24 VDC ±10% 12 to 24 VDC ±10% 12 to 24 VDC ±10%
Current consumption 50 mA max. 35 mA max. 35 mA max. 35 mA max. 35 mA max.
Ambient light Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.
Ambient temperature -10 to +55° C -10 to +55° C -10 to +55° C -10 to +55° C -10 to +55° C
Housing Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate
Weight
Approx. 75 g Approx. 61 g Approx. 61 g Approx. 61 g Approx. 61 g
(including 2-m 6.6' cable)

Connections
FS-T22 FS-T22P
NPN Brown PNP Brown
100 mA max.
Black Black
Load Load
50 mA max. 12 to 24 VDC 12 to 24 VDC
Orange
Load Load
Orange
Blue Blue

Pink Pink
Input for external Input for external
calibration calibration

FS2-60/FS2-62/FS2-65/FS2-60G FS2-60P/FS2-62P/FS2-65P
NPN PNP
Brown Brown
100 mA max.
Black Black Load
Load
50 mA max. 12 to 24 VDC 12 to 24 VDC
Orange Orange
Load Load
Blue Blue

93
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

FS2/FS-T22 Fiber Photoelectric Sensors

Input/Output Circuits
FS-T22 Output circuit
NPN PNP
Brown Brown

Load
Black

Load
Short-
circuit (Control output) Short-
12 to 24 VDC
Main circuit

protec- circuit Black


Orange 12 to 24 VDC

Main circuit
tion protec-
(Alarm output) (Control output)
circuit tion
circuit Orange

Load
Blue (Alarm output)

Load
Pink Blue
(External calibration)
Pink
(External calibration)
FS-T22(P) Input circuit
Input circuit for external calibration

12 to 24 VDC
1.8 kΩ

470 Ω
1.8 kΩ
Yellow

Input impedance: Approx. 4 kΩ

FS2 Output circuit


NPN PNP
Brown Brown
Load

Short-
Load

12 to 24 VDC circuit
Main circuit

Black
Main circuit

Black 12 to 24 VDC
(Control output) protec-
Short- (Control output)
tion
circuit Orange circuit Orange

Load
protec- (Alarm output) (Alarm output)

Load
tion
circuit
Blue Blue

Adjustment
FS-T22
Thrubeam type/ Diffuse-reflective type
Setting the sensitivity Setting to maximum sensitivity
1. With a target in place, press the SET When a reflective sensor is used for long distance
pushbutton. The yellow LED lights. detection or a thrubeam sensor is used for detection in an
set unstable environment, follow the procedure given below
to set the sensitivity to maximum.
1. With (thrubeam), or without (reflective) a
2. With no target, press the SET pushbutton.
target in place, hold the SET pushbutton
The yellow LED turns off. Setting is
set complete. If sensitivity cannot be set
set down for 3 seconds. When the yellow LED
starts flashing, setting is complete. With a
because the received light quantity with and
reflective sensor, if there is a background
without a target is too small, the green LED
object, set the sensitivity to the highest
flashes for approx. 2 seconds.
setting that will not detect the background
set
3. Check sensor operation. object.

set
2. Check sensor operation.

Procedures 1 and 2 can be reversed. set

94
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Fiber Photoelectric Sensors FS2/FS-T22

Precautions
Stability indicator Sensitivity setting protection
When setting the sensitivity, it flashes to indicate the To prevent the sensitivity from being accidentally
sensitivity setting has been rejected due to small excess changed, set the sensitivity setting protector switch to
gain and that the current sensitivity remains valid. LOCK. The sensitivity will not change even if the SET
pushbutton is pressed.
[Note]
External sensitivity Brown This function does not prevent changes in sensitivity
+V
adjustment input externally, or operation mode or timer mode
The sensitivity can be set changes.
from external device, Blue 0V
rather than using the SET Pink
pushbutton on the Contact or Self-diagnosis
solid-state input
amplifier unit. Use an (NPN only) • If the sensitivity cannot be set, the green LED flashes
input signal of 40 ms or and the alarm signal is output for 2 seconds.
more.
• If, after the sensitivity has been set, the received light
quantity falls below a specified level due to dirt on the
lens or misalignment of the optical axis, the alarm
output is triggered.

FS2
Thrubeam type Diffuse-reflective type
DARK-ON mode (When LIGHT-ON mode is specified, LIGHT-ON mode (When DARK-ON mode is specified,
refer to words in parentheses.) refer to words in parentheses.)
1. With a target in place, turn the trimmer 1. With no target, turn the trimmer clockwise
clockwise until the red LED indicator turns until the red LED indicator lights (turns off).
off (lights). – Point A – Point A
A A

B 2. With no target, turn the trimmer counter- B 2. With a target in place, turn the trimmer
clockwise until the green LED lights (turns counterclockwise until the green LED turns
off). – Point B off (lights). – Point B
A A

Optimal 3. Set the trimmer midway between points A Optimal 3. Set the trimmer midway between points A
B position B position
and B. Confirm sensor operation. and B. Confirm sensor operation.

A A

Precautions
Adjustment with alarm buzzer Adjustment with the trimmer
• The output indicator operates in conjunction with a built- cap
Trimmer cap
in buzzer when the alarm selector switch on the top of • Adjust the trimmer with the (detachable)
the amplifier unit is set to the OUT position, facilitating trimmer cap or with a
adjustment. screwdriver.
• When the alarm selector switch is set to the STB
position, the alarm buzzer sounds when light quantity is
reduced by an accumulation of dust or dirt on the lens
surface, or when the optical axis is out of alignment
(through-beam sensor).
• Set the alarm switch to the OFF position to deactivate
the buzzer function.

95
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

FS2/FS-T22 Fiber Photoelectric Sensors

Timing Chart
LIGHT-ON mode DARK-ON mode
1 2 3
1 2 3
Stable operating level
Stable operating level Operating level
Operating level

ON
Red LED
ON OFF
Red LED
OFF
ON
Green LED
ON OFF
Green LED
OFF
ON
Control output
ON OFF
Control output
OFF
ON Reset
Reset Alarm output
ON OFF
Alarm output
OFF

• If the light quantity received by the receiver of the • If the light quantity is not restored to a stable level after
sensor drops from a stable level 1 to an unstable level detection of a target 2, the alarm output is triggered
2, the alarm output is triggered. when detecting a second target 3.

• If the alarm output is triggered, clean the lens surface


and/or realign the optical axis so that the stable
operation indicator lights again. Operating the sensor
with the green LED lit resets the alarm output.

Hints on Correct Use


FS-T22 (P)
Mounting the fiber unit • Two adapter types are supplied. Select the proper one
• Pull open the quick release lever. Insert the fiber unit as for the fiber unit to be used. If the wrong adapter is
far as possible. Close the quick release lever. used, the fiber unit cannot be securely mounted.

Quick release lever

Applicable fiber units: Applicable fiber units:


FU-63, 63T, 66, 43, 35FA, 32, 91, 93 FU-48, 68, 59, 75F, 79, 37

• The mounting ring and connector attached to the fiber


unit are not used.
• When mounting the FU 63, 63T, 66, 43,48, 68, 35FA,
59,79, 75F, 32, 91, 37, or 93 fiber unit to the amplifier,
use the adapter supplied. Mounting the amplifier to a DIN rail
Hook the claw located at the
1. Fully insert the adapter into the holes.
bottom of the amplifier to a
2. Insert the fiber unit into the adapter as far as possible. DIN rail, and push the
amplifier against the DIN rail.
To detach the amplifier, pull it
up while drawing it toward the
fiber unit side.

Amplifier
• When the external tuning input is not used, cut the pink
cable very short or connect it to the positive terminal of
the power supply.

• Limit the length of extension to within 100 m 328.1'.

96
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Fiber Photoelectric Sensors FS2/FS-T22

FS2(P) & FS-T22(P) Using the cutter


Fiber unit Cut the free-cut fiber unit to the desired length using the
attached cutter.
• Avoid strong impact to the surface of the fiber unit head.
• When mounting the fiber unit using a mounting screw,
do not exceed the tightening torque specified below. 1. Insert the fiber unit into the
corresponding cutter hole to the
Mounting with set screw desired length. 1
M3 set screw 0.02"
5 mm min. 2. Cut the fiber by quickly pushing
(flat point or cut point)
the blade all the way down.
2
Stopping the blade midway will
prevent a clean cut, thereby
Tightening torque: 0.3 N•m lessening the detecting distance.
(approx. 3 kgf•cm) max. Do not use a cutter hole more
than once.
Mounting with nut and bolt
Screw size Tightening torque Using the splitter
M3 0.6 N•m max.
To split the tip of the free-cut fiber unit after cutting it, use
M4
0.8 N•m max. the attached splitter (for FU-4F, 66, 63, 63T, 43, 91 and 93
M6
only). If you use any device other than the attached
• Do not apply undue force to the fiber unit. splitter, the sheath of the fiber unit may tear.
• Fiber units other than those listed below have a tensile
strength of 3 kg for 3 seconds maximum. 1. Lift the head of the splitter. Insert
the fiber unit straight into the
Model Tensile strength 7"
splitter in the opposite direction to 1.5 mm
FU-81C, 82C, 83C, 84C 2 kg for 3 sec max. 40
the arrow (-PULL) until it pro-
FU-63, 63T, 43, 65, 65X, 45, 45X, 49, 49X, 59, 1
79, 75F, 32, 36, 36X, 35FA, 22, 37
1 kg for 3 sec max. trudes approximately 40 mm
1.57".
• When mounting the coaxial type fiber unit (FU-23, 23X,
25, 35A, 35FA, 22, 22X) to the amplifier, connect the 2. Firmly press the head of the
single-core fiber to the transmitter, and multiple-core splitter down.
fiber to the receiver. 2
3. Pull the fiber unit straight out from
[Note] 3
the splitter in the direction of the
The transmitter emits light from the upper hole of the FS-
arrow (-PULL). It will be split at
T22 and from the lower hole of the FS2.
approximately 50 mm 1.97" from
the inserted end.

Single-core fiber Amplifier mounting


connector Mounting the amplifier
Multiple-core fiber (for FS2 only)
Do not extend the cable beyond
100 m 328.1'.
• Bend the sleeve type fiber unit by manually bending Mounting the FS2 amplifier to
it around a cylindrical object of a minimum radius of a DIN rail
10 mm 0.39" (25 mm 0.98" for FU-33/34. Do not Hook the claws located at the
bend FU-65, 65X, 75F, 43, 32.) Do not bend the bottom of the amplifier to a DIN
sleeve more than three times. rail, and push the amplifier
against the DIN rail to hold it. To
• Do not heat the sleeve of the heat-resistant type detach the amplifier, pull it up
fiber unit after heating the unit. while drawing the DIN-rail
fixtures located in the cable side
of the amplifier as indicated by
the arrow.
Side mounting
Use the attached mounting
bracket. Secure the mounting
• Do not use the fiber unit in an environment where
bracket in place with two screws.
organic solvents such as thinner are present.

97
MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

FS2/FS-T22 Fiber Photoelectric Sensors

Dimensions CAD

Amplifier unit Unit: mm Inch


FS-T22(P) FS2-60(P)/62(P)/65(P)/60G ø0.16" 0.01"
ø4, 4 x 0.15 mm2 core
0.18" Calibration trimmer Indicator Cable length: 2m 6.6'
4.5 x 0.15 mm2 core
Cable length: 2m 6.6' 12.5 ø9.4 1.2 0.05"
0.49"
0.51" 13
ø0.37" 10
14.5
0.16" 0.57" 0.39"
4
When the amplifier is mounted to a DIN rail

0.16" 1.30" Fiber unit 2.7 0.10"


4 33
37.3
1.47" 25.9
19.3
7.5 0.76" 1.02" (30.2)
(17.7)13.4 12 (1.19")
0.7 (0.70") 0.53" 0.47"
0.30" 0.13" 3.2
0.03"
12 35.7
0.47" 1.41" 2 5.5 35.4
59 0.22" 1.39"
2.32" 0.08" 6 53.5 4
0.24" 2.11" 0.16"
Figures in ( ) apply when the amplifier is
mounted on a DIN rail.

When the mounting bracket (standard) is used


Fiber unit 2.7
0.11"

38.5 31.2
1.52" 1.23"
0.12" 0.81" 18.7
3 17.3
20.5 0.74" 0.68"
ø0.13 5.5 3
0.52" 2 x ø3.2 0.22" 4.5 0.18" 0.12"
13.1 1.00" 0.11" 2.8 2 x ø3.2 ø0.13"
15.9 25.4 Spot facing: 8, 4(d) 25.4 1.00" mounting hole
0.63" 31 0.31, 0.16(d) 7.7 31
1.22" 0.30" 1.22"

12.5 0.49" Rear view of 12.5


mounting bracket 0.49"

15 2 x ø3.4 ø0.13 2 x ø3.4 ø0.13"


0.59" 15
31 Spot facing: 8, 4(d) 0.59" Spot facing: ø8, 4 (d)
1.22" 0.31, 0.16(d) ø0.31", 0.16"(d)

Fiber unit
For dimensions of the fiber units, refer to the FS01 Series dimensions.

98