COMPANY

Marubeni-Itochu Tubulars Asia Pte Ltd


PERSON
Materials Recommendation for PEL’s Upcoming Well
DATE
Data Received: Well Environment
Data received: Gas Composition
Well Data & Corrosion Assessment

BHT (deg F/deg C) BHP (psi/MPa) SIWHT (deg F/deg C) CO2 (Mol%) H2S (ppm)

250/121.1 3500/24.1 77/25 (Assumed) 4.1 0

Water CO2 pp (psi/MPa) H2S pp (psi/MPa) Cl-/HCO3-/Organic Acids (ppm) pH* Highest Corrosion Rate* (Carbon Steel)

Produced Water 143.5/1.0 0/0 50000/0/0 3.6 >250 mm/y

Condensed Water 143.5/1.0 0/0 1000/0/0 3.5 156 mm/y

*Calculated by Predict 7.1


Note:
1. Gas Flow Rate= 12 MMSCFD
2. Water Flow Rate= 100 bpd
3. Condensate Flow Rate= 75 bpd

1. Based on simulated corrosion rates, carbon steels are not suitable for the given well conditions.
2. Since the H2S partial pressure is lower than 0.05psi, the well condition is in Sour Region 0, defined by
ISO15156. Therefore, SSC is not an issue.
Application of NACE MR0175/ISO1516 (SSC/SCC Evaluation)

13Cr-L80 Limits defined by ISO15156.

Based on ISO15156, 13Cr-L80 is suitable for use under the given


conditions.
Highest Temp Highest H2S Partial Pressure Chloride in Brine , ppm Lowest pH
Worse Case corrosion factors.

121.1 deg C 0 bar 50000 3.5


Conclusions for Upcoming Well

Candidate Material Conclusion on Suitability

Carbon Steel ×

13Cr-L80 ✓
Thank You