Title DI1 (60 105m/min) Annunciator Function Setting Mode
Title DI1 (60 105m/min) Annunciator Function Setting Mode
Title DI1 (60 105m/min) Annunciator Function Setting Mode
29
5.ANNUNCIATOR
Contents It is intended to help you operate annunciator properly, explain LCD indication and give you check points
when floor height measuring operation has failed during installation and maintenance.
** Preparation **
1. Set the NORMAL/STOP switch on DOC-100 PCB to the STOP position.
2. Check JP1 S/W on DOC-100 PCB.
It shall be in a writable area.(Turn OFF R5SC to move JP1 S/W and then turn ON R5SC again.)
** Screen check **
1. Verify that ACD = 09 after entering "A12E" and press '3'.(This is maintained until bottom FLR DL S/W is inputted.)
A C D = 0 9 0 0 F L 0 0 M 0 1 2 3 A 1 2 E
E 0 0 0 - 0 0 1 0 0 0 0 S 4 5 6 7
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1 8 9 A B
F H M M D K : C D E F ① ② ③ ④
A C D = 0 A 0 0 F L 1 5 M
E 0 0 0 - 0 0 1 0 0 0 0 U
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
F H M S T K :
5.When floor height measuring operation has started, FHM ST displays in row 4.
6.The car will travel until UL switch operates.
7.When floor height measuring has completed, LCD screen state is;
A C D = 0 A 1 6 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
F H M P A S S K :
8.If FHM is successful, FHM PASS will display.
9.Move JP1 to +5V position with NORMAL/STOP switch on DOC-100 PCB to STOP position, in order to
stop the floor height measuring operation.
A C D = 2 7 1 6 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
K :
12.ACD=27 will display in automatic mode.
13.If FHM has failed, the screen will be;
A C D = 0 9 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S Checking points when FHM has failed
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1 * Isn't JP1 in 5V area?
F * Isn't Total[0]($0300H) data different from Top($041CH) data?
H M F a i l K :
* Doesn't SD1U operate abnormally after arrival at top floor?
①.FHM Fail,which means floor height * Doesn't UL or DL switch operate abnormally?
measuring has failure, will display. * Are not input devices(CDS,LDS,SES,etc.) of door operating
②.The car will return to the bottom floor automatically. abnormally?
- 131 -
D A T E:'97.11.29
It is intended to run the car from the top, intermediate and bottom floor by using annunciator, and verify
Contents
the car is in a normal condition by registering hold type call(continuous operation).
** Screen check **
1. Enter 'A18E' and verify that TOP FL will display in row 4.
2. The car moves to the top floor and stop.
3. To clear the mode, enter FFFF.
A C D = 2 7 1 0 F L 0 0 M
**Note**
Hold type call floor input is used for a successive operation for E 0 0 0 - 0 0 1 0 0 0 0 S
bottom F, intermediate F, and top F. 1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
Ex.:If'A16E' and'A18E' are registered,
T O P H F L K :
continuous operation for bottom F and top F
If 'A16E', 'A17E' and "A18E" are registered.
(continuous operation of bottom floor, intermediate floor, and top floor)
** Screen check **
1. Verify that CALL will display in row 4 after registering A19E, A C D = 2 7 0 0 F L 0 0 M
and enter a floor. Decimal number is used for floor call. E 0 0 0 - 0 0 1 0 0 0 0 S
For 8 F call, enter '08E'.
For 12 F call, enter '12E'.
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
2. Automatically reset.(Min.:After the car reaches specified floor, Max.:35sec.) C A L L K :
- 132 -
D A T E:'97.11.29
It is intended to help you check the data of input/output buffer with READ/WRITE mode by using
Contents
annunciator during installation and mainterance.
** Preparation **
1. Move NORMAL/STOP switch on DOC-100 PCB to the STOP position.
2. Check JP1 switch on DOC-100 PCB.
①.JP1 switch should be in +5 area when reading RAM.
②.JP1 switch should be in a writable area when writing RAM.
** Screen check **
1. Enter 'A21E' and verify that ADDR ; DAT will display in row 4.
A C D = 0 3 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
A D D R ; D A T K :
A C D = 0 3 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
0 1 0 0 ; x 1 C K :
Address and data indicated are in hexadecimal value.
'x' in 'x1C' means HEX(Hexadecimal) value and '1C' is actual data.
3.Address increment
When reading the data of higher address than the address inputted, register ' 0'.
4.Address decrement
When reading the data of lower address than the address inputted, register ' 8'.
5.Address input conversion
To read another address when reading data, register 'BBB'.
A C D = 0 3 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
A D D R ; D A T K :
6.Data protection release and data input
Read the data of the address to make correction and then enter ' AAE'.
LCD screen state
A C D = 0 3 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
0 1 0 0 ; x 1 C K : A A E
7. Enter the two-place data to modify, using HEX.
① Data to enter is a HEX value.
Ex.)If the data to correct is '13' of decimal number, enter '0CE'.
A C D = 0 3 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S Check points when writing data
* The car should be in operative.
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
* Be sure to verify that JP1 switch is in a writable area.
0 1 0 0 ; x 1 C K : 0 C E * Do not operate JP1 switch while the car is running.
8. To escape the mode, enter 'FFFF'. * In data mode, addresses of 0x0000~0xffff can be registered.
(Actual address is 40000~4ffff.)
- 133 -
D A T E:'97.11.29
This is for checking and correcting the data of absolute address the spec. ROM in installation and
Contents
maintenance with readable/writable mode by using annunicator.
A C D = 0 3 0 1 F L 0 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
S P E C ; D A T K :
A C D = 0 3 0 0 F L 0 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
0 0 2 C ; x 0 1 K :
Address and data displayed is in a HEX.
'x' in 'x01' means HEX value and '01' actual data.
3.Address increment
When reading the data of the 2 address higher address than the address inputted, enter '0'.
4.Address decrement
When reading the data of the 2 address lower address than the address inputted, enter ' 8'.
5.Address input conversion
To read another address when reading data, enter 'BBB' .
LCD screen state
A C D = 0 3 0 0 F L 0 0 0 M **Note**
E 0 0 0 - 0 0 1 0 0 0 0 S ⓐ .As SPEC data uses only the lower 8BIT of 16BIT,
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1 always use even number only.
S P E C ; D A T K : ⓑ .If an odd number is entered by mistake, it is
6.Data protection cancel and data input considered as the appropriate even number.
Read the data of the address to make correction and enter 'AAE'.
LCD screen state
A C D = 0 3 0 1 F L 0 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
0 0 2 C ; x 0 1 K : A A E
7. Enter the two-place data to correct, using HEX.
Ex.)If the data to correct is '13' of decimal number, enter '0C'.
LCD screen state
A C D = 0 3 0 1 F L 0 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S Check points when writing SPEC fails
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1 * Verify that NORMAL/STOP S/W in OC-100 PCB is in STOP position.
0 0 2 C ; x 0 1 K : 0 C E * Be sure to verify that JP1 S/W is in a writable area.
* Do not operate JP1 S/W while E/L is running.
If writing data is failed, 'FAIL'is displayed. * During SPEC write, addresses of 0x0000~3fff may be entered.
8. To escape the mode, enter 'FFFF'. (Actual address is 50000~53FFF.)
* Address moves by 2 addresses during SPEC write/read.
- 134 -
D A T E:'97.11.29
A C D = 2 7 0 1 F L 0 0 M
E 0 2 7 - 9 4 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
T 0 1 6 - 0 0 1 K :
①.Row 2 shows TCD code and operation code as well as TCD display.
②.Row 4 shows the total number of TCDs which are stored in LOG TABLE in a T0xx form
and indicates how much time the TCD code in row 2 is displayed in a -0xx form.
③.Enter '0' to search back from the content display now, and enter '8' to search forth.
④.Enter "1" to search the first error of all errors which have occurred till now.
⑤.Enter "9" to search the last error of all errors which have occurred till not.
⑥.Up to 16 errors can be searched from ERROR LOG TABLE.
⑦.ERROR LOG TABLE is a FIFO structure.
- 135 -
D A T E:'97.11.29
This is for checking and correcting during installing & maint. through the mode that can read/write data
Contents
of DSP memory by using annunciator.
** Screen check **
1. After entering A51E, verify row 4 is DSP ADDR.
LCD screen state
A C D = 2 7 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
D S P A D D R K :
2.After entering address to read to four places of Hex, enter 'E'.
Ex.) If '1000' address is entered,
LCD screen state
A C D = 2 7 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 0 0 0 = x 3 1 2 F A A 5 5
D S P A D D R K :
ADDRESS and DATA are displayed in row 3.
ADDRESS and DATA displayed are Hex.
The 'x' in 'x321F AA55' means Hex value, and '321F AA55' is actual DATA.
DATA displayed is amount of 4 bytes of Hex.
3.ADDRESS INCREMENT
If data of the upper address than the entered address is read, enter '0'.
Data of the 4 upper address above already entered address is displayed.
4.ADDRESS DECREMENT
If data of the lower address than the entered address is read, enter '8'.
Data of the 4 lower address below already entered address is displayed.
5.If mode is released, enter FFFF.
- 136 -
D A T E:'97.11.29
Contents This is for checking & correcting during installing & maint. through the mode that can measure and
correct NO LOAD POINT & FULL LOAD POINT of differential trs by using annunciator.
A C D = 0 3 0 3 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
S U C C E S S K :
A C D = 0 3 0 3 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S Check points during NO LOAD POINT setting failure
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1 * Verify NORMAL/STOP S/W in DOC-100 PCB is in STOP.
F A I L K : * Verify JP1 S/W is surely in WRITE area.
* Check SPEC DATA of 014E.
If FAIL displayed, set N0 LOAD POINT again.
3. To release MODE, enter FFFF. (default=00H)
** Preparation **
1. Switch NORMAL/STOP S/W of DOC-100 PCB to STOP.
2. Verify JP1 S/W of DOC-100 PCB is in WRITE area.
3. Verify R5SC(for checking safety circuit) RELAY of DOC-100 PCB is OFF.
4. After setting NO LOAD POINT, set FULL LOAD POINT.
** Screen check **
1. Enter A62E.
LCD screen state
A C D = 0 3 0 3 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
K : A 6 2 E
A C D = 0 3 0 3 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
S U C C E S S K :
- 137 -
D A T E:'97.11.29
This is for using night noise restricting function by using the function that sets and changes time
Contents
through annunciator, which is used in installing & maintenance.
A C D = 02 37 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
9 8 0 1 1 3 / 1 5 : 0 3 : 1 0 /#
R T C S E T K :
** 화면 확인 **
1. 시간을 변경하고자
②. Hour, 할 Second
Minute, 경우'C'를입력하여
setting screen
LCD화면의 4행에 TameSet를 확인한다.
2. 변경하고자 하는 시간,분,초,를 순서대로 입력한다. A C D = 02 37 0 0 F L 0 0 M
**예)오후
Screen check **
3시45분30초 입력한다면:15E,45E,30E를 입력한다. E 0 0 0 - 0 0 1 0 0 0 0 S
1. For
2. changing
MODE를 해제할time,경우 enter
FFFF를'C', and
입력한다. 9 78 01 1 12 93 / 1 5 : 0 3 : 1 0 /
verify row 4 of LCD screen is TimeSet. R T C S E T K :
2. Enter Hour, Minute, Second to change in order.
Ex.) For entering P.M 03:45, 30 sec : enter 15E,45E,30E. A C D = 02 73 0 0 F L 0 0 M
3. Check hour, minute, second entered in row 4. E 0 0 0 - 0 0 1 0 0 0 0 S
4. To release MODE, enter FFFF.
9 87 01 1 12 3 / 1 5 : 0 3 : 1 0 #
5. If setting time is wrong, Key error is displayed.
Ex.) 25 hour,30 minute,62 minute, 65 second, etc. TD ia mt e S e t K : 91 58 E
A C D = 02 37 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
9 87 01 1 12 3 / 1 5 : 0 3 : 1 0 #
19 58 / / K : 04 51 E
A C D = 20 73 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
9 87 01 1 12 3 / 1 5 : 0 3 : 1 0 #
19 58 / 40 51 / K : 13 03 E
A C D = 02 37 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
9 8 0 1 1 3 / 1 5 : 40 53 : 13 0 #
R T C S E T K :
- 138 -
D A T E:'97.11.29
This is a mode to measure POSI characteristics by using annunciator, which is used during installing
Contents
& maintenance for correct positioning & minimizing shock of positioning.
** Preparation **
1. Switch MAINT/AUTO of DOC-100 PCB to MAINT.
Measuring POSI must be performed in M/C room low speed running mode.
2. Operate UP/DOWN S/W up/down to perform.
3. Switch JP1 S/W of DOC-100 PCB to WRITE.(JP1 S/W moving must be performed in state of R5SC RELAY OFF.)
4. In POSI measuring MODE, car must be in the other floor than top, bottom floors.
5. Car may not be in DOOR ZONE. Performing in any floor has the same result.
** Screen check **
1. After entering A85E, verify row 4 is POSI TEST.(verify ACD = 04.)
LCD screen state
A C D = 0 4 0 2 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
P O S I T E S T K :
①.If car is in DOOR ZONE, 'POSI TEST' is displayed.
②.If car is out of DOOR ZONE, 'UP Drive' is displayed just after 'POSI TEST' displayed.
Move car according to directions of LCD screen.
2.When car is in DOOR ZONE
①.Operate UP/DOWN S/W of DOC-100 PCB up/down to move out of DOOR ZONE.
②.If car moves out of DOOR ZONE, 'UP DRIVE' meaning up-running is displayed.
LCD screen state
A C D = 0 4 0 2 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
U P D r i v e K :
③. If UP DRIVE is displayed, switch UP/DOWN S/W to UP.
④. Measure POSI characteristics passing by DOOR ZONE.
⑤. After measuring finished, 'DN Drive' meaning reverse in car direction is displayed.
LCD screen state
A C D = 0 4 0 2 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
D N D r i v e K :
⑥. If 'DN DRIVE' is displayed, switch UP/DOWN S/W in DOC-100 PCB to DOWN.
⑦. Measure POSI characteristics passing by DOOR ZONE.
⑧. If cat is out of DOOR ZONE, 'STOP' message is displayed.
A C D = 0 4 0 2 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
S T O P K :
3.If measuring POSI is finished. 'POSI FIN'is displayed in row 4.
LCD screen state
A C D = 0 4 0 2 F L 0 0 M **Check points during POSI measuring failure**
E 0 0 0 - 0 0 1 0 0 0 0 S * Is not JP1 S/W in 5V area?
* Is not MAINT/AUTO S/W in AUTO?
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
* Is not car in top or bottom floor?
P O S I F I N K :
- 139 -
D A T E:'97.11.29
This is a fucntion to maximize facility of installation and maintenance by using a mode that can
Contents
confirm car load through annunciator. (applied to only case of differential trs)
** Cautions **
1. Verify DOC-100 PCB is normal.
2. Verify BIT4 of SPEC1 DIP S/W in DOC-100 PCB is ON state.
3. Verify differential trs is a applied E/L.
Ex.) Checking ADDRESS of SPEC TABLE.
When 1 differential trs applied(=0018H), when 2 differential trs's(=001AH)
*Reference for applying differential trs*
60m/min 17 persons(standard type) :DATA of 0018H is '01'.
60m/min 17 Persons :DATA of 0018H is '01', DATA of 001AH is '01'
90m/min 15 Persons or less : DATA of 0018H is '01'
90m/min 15 Persons or more : DATA of 0018H is '01', DATA of 001A is '01'
** Screen check **
1. Enter A86E, and verify WD:00% in row 4.
LCD screen check
A C D = 2 7 0 2 F L 6 0 M
E 0 0 0 - 0 0 1 0 0 0 0 U
0 0 0 0 0 0 0 0 0 0 0 0
W D : 2 0 % K :
*MODE explanation*
This is a function that can run only once with buzzer not buzzed when loading 110% load in car.
This is a mode used when elevator superintendent inspects it.
** How to use**
1. If load 110% is loaded, buzzer buzzes and door is maintained in state of opening.
2. Enter target floor, and then enter A88E.
3. E/L runs towards target floor only once.
4. It is reset automatically.
** Screen check **
1. If A88E is entered, buzzer sound does not buzz.
2. E/L runs towards target floor.
LCD screen state
A C D = 2 7 0 1 F L 1 5 M
E 0 0 0 - 0 0 1 0 0 0 0 U
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
K :
- 140 -
KEY INPUT ASSIGN. TAB. BY ANN FUN. MODE
Address DEC 8
- 141 -
Address input BBB FFFF
PROTECTION release AAE
Data input XXE
Error mode TCD DISPLAY A41E TABLE INC 0 FFFF
TABLE DEC 8
ERROR LOG TABLE A42E TABLE INC 0
TABLE DEC 8
TABLE 1st error 1
Other mode POSI measuring mode A85E UP OPR (SW OPR) UP FFFF
DOWN OPR ( " ) DOWN
- 142 -