1. EZ-Trac Assembly
2. EZ-Com ‘SINGLE’
3. EZ-Com ‘MULTI’
4. Orientation Assembly
5. EZ-Com ‘ORIENTATION’
6. EZ-Com Download
7. Trouble Shooting
Ez Trac Parts
EZ Trac Assembly
EZ Trac Assembly – Multi / Single Shot
EZ Trac Assembly – Multi / Single Shot
RC Drilling
EZ Trac Assembly – Multi / Single Shot
2. EZ-Com SINGLE
Navigation Buttons
2. EZ-Com SINGLE
This method of surveying is used to take multiple survey readings at pre determined depth
intervals with out the need to retrieve the instrument and reset each time.
• IN & OUT – The EZ-Com is set to take readings as it is lowered INTO the borehole and then
OUT of the borehole as it is retrieved providing 2 x survey runs of data at the same depths.
NB: This method is good for confirming magnetic zones in the formation being drilled.
• IN & OUT SPLIT – This survey is run INTO the borehole as per the ‘IN & OUT’ method but
the survey depths are changed on the OUT survey to take survey readings in-between the
previous IN depths.
NB: This method is good for identifying directional trends in the borehole .
• REVERSE – This method is the quickest and involves releasing / pumping the instrument
down into the coring barrel and performing an OUT survey as the drill rods are retrieved.
NB: This method will not lengthen the time taken to trip the rods and should be used when
the opportunity arises to retrieve the BHA i.e. Bit Change.
Multi Shot Survey - Reverse
10. The instrument can now be lowered into the rod string and dry released or pumped
down connected to the bottom of the inner tube using a lifter case adaptor.
1. Once the instrument has landed, allow 30 seconds for
the instrument to settle. MEASURE is highlighted;
press OK to take the shot.
Note: REFLEX™ EZ-COM will hibernate if not used 4. Pull the instrument to surface. Undo the instrument
for 2 minutes. Press the ON button to from the top sub to expose the IR port. Highlight
continue. DOWNLOAD, point the IR ports at each other and
press OK. This will retrieve the following information:
2. Raise the drill string to the desired survey interval Azimuth, Inclination, Magnetic Field (nT), Magnetic
(e.g. 9m). MEASURE is highlighted; press OK to take Dip, Gravity, Temperature.
the shot. Repeat this step until the drilling barrel is at
the surface. 5. Using the left and right arrows you can scroll through
Note: The shot can be taken while the drill rod is other survey depths.
being taken off.
Note: If you are not sure whether or not a good
survey has been taken, highlight STOP and
press OK. Then highlight REDO survey
station and press OK. Repeat step 12. 6. To return to the MAIN menu, scroll down and highlight
Note: To end the survey at any time, highlight STOP MAIN MENU. Press OK
and press OK. Then highlight End survey and
press OK. Go to step 14.
The EZ-Trac can be used to orientate BHA( Bottom Hole Assembly) such as
wedges and down hole motors. Orientating digitally reduces the incidence of
error as the BHA can only be ‘zeroed’ to TDC (Top Dead Centre).
Set Up
A Mule Shoe is connected directly to the bottom of the EZ-Trac via an adaptor.
Remove ‘Bump Sub’ and connect Mule Shoe Adaptor
4. Orientation Assembly
Casing and Hall Rowe Wedges
Completed Assembly
4. Orientation Assembly
Navigational Motors
Completed Assembly
5. EZ-Com ORIENTATION
1. The BHA (Wedge/Motor) can now be run into the hole to depth, and the survey
instrument can be prepared for the orientation survey.
Note: REFLEX™ EZ-COM will hibernate if not used for 2 minutes. Press the ON
button to continue.
2. Highlight INIT, point the IR ports at each
other and press OK.
1. Run the instrument into the BHA via
wireline. MEASURE is highlighted. Once
3. The Gravity Toolface is displayed in
the instrument is in position, press OK to
take the shot.
degrees from zero (TDC). Press OK to
continue and display the ORIENTATION
menu.
Survey data is downloaded from the EZ-Com to a PC via the USB port. The EZ-Com is
seen as another drive i.e. ‘F Drive’ and when opened the three below folders will appear
on the PC screen.
Depending on the survey method open the corresponding folder and copy the survey
files to your PC.
Once copied to the PC the original files can be deleted from the below folders on the EZ-
Com.
USB Port
7. Trouble Shooting