17/09/2016 SAE J1939 Data Link ­ Abnormal Update Rate

FAULT CODE  427 
SAE J1939 Data Link ­ Abnormal Update Rate

  Printable Version

Overview

CODE REASON EFFECT


Fault Code:  427 
PID: S231 J1939 Data Link ­ Abnormal Update Rate. Communication Engine speed
SPN: 639 between the electronic control module (ECM) and another will ramp down
FMI: 9/9 device on the SAE J1939 data link has been lost. and remain at
LAMP: None idle.
SRT: 

SAE J1939 Data Link Circuit
SMALL | MEDIUM | LARGE

Circuit Description

Devices such as ABS controllers, autoshift transmissions, ASR systems, electronic displays,
electronic information systems, electronic service tools, and vehicle electronic control unit(s)
(VECUs) can communicate with the ECM over the SAE J1939 data link. Messages sent from the
devices are received by the ECM and used for controlling the engine. The ECM also transmits
information to these devices over the SAE J1939 data link.

Component Location

The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options. 
https://quickserve.cummins.com/qs3/pubsys2/xml/en/procedures/120/120­fc427.html?q=427 1/2
17/09/2016 SAE J1939 Data Link ­ Abnormal Update Rate

Conditions for Running the Diagnostics

This diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault Codes

The ECM does not receive a valid J1939 message from a multiplexed device for more than
1second. The ECM detects an open or short circuit condition in the J1939 data link harness.

Action Taken When the Fault Code is Active

The ECM will log the fault code immediately when the diagnostic runs and fails.

The ECM will use a default state as an input for the multiplexed device.

Conditions for Clearing the Fault Code

To validate the repair, start the engine and let it idle for 1 minute.

The fault code status displayed by the INSITE electronic service tool will change to
INACTIVE immediately after the diagnostic runs and passes.

The “Reset All Faults” command in the INSITE electronic service tool can be used to clear
active and inactive faults.

Shop Talk

Possible causes of this fault include:

Electrical problems with the SAE J1939 data link wiring such as grounded, shorted, or open
circuits

The ECM (or another SAE J1939 device) tying up communications by sending too many
consecutive messages

The external OEM controlling device has malfunctioned or can no longer transmit on the data
link.

Refer to Troubleshooting Fault Code  427 .