Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

AC MOTOR DATASHEET

AC MOTOR DATASHEET (Jawaharpur_COC Drive_0.37kW)
SL. No. Description Unit Vendor Data
1.01.00  Manufacturer NORD Drivesystems Pvt. Ltd
3 Phase AC Squirral Cage Induction Motor IE3 & 
1.02.00.  Type and frame size
Frame ‐71
1.03.00  Design code no. NA
1.04.00. Nos. required 16
1.05.00. Application Gravimetric BWF ‐ COC Drive
1.06.00 Specification & Codes IEC60034/IS
1.07.00  Capacity for
i) for specified climatic conditions (50 Deg C) kW 0.37
ii) At 40 Deg C ambient kW 0.4
1.08.00.  Location for installation Outdoor
1.09.00.  Type of enclosure & ventilation TEFC (IC411)
1.10.00.  Degree of protection IP 55 with Canopy
1.11.00  Type of duty S1
1.12.00.  No. of phases, frequency & voltage 3 PH, 50Hz, 415V
1.13.00. Permissible variations in
a) Voltage % ±10%
b) Frequency % ±5%
c) Combined % 10% (ABSOLUTE)
1.14.00.  At rated voltage & frequency
a) Full load current A 1.52/0.88
b) Full load speed A 1405
c) No load current A 1.06/0.61
1.15.00.  Minimum permissible voltage during starting V 332V (80%)
Maximum permissible time at minimum permissible voltage during running at full 
1.16.00.  Sec. 8 SEC
load.
1.17.00.  Maximum permissible time at 75% of rated voltage during running at full load. Sec. 9 SEC
1.18.00.  Whether motor stalls at 70% of rated voltage (Yes/No) NO
1.19.00  Efficiency & power factor
Load (% of full load)
100 72.7 & 0.7
75 72.2 & 0.68
50 71.7 & 0.65
25 70.5 & 0.5
0 NA & 0.2 (INDICATIVE)
At start NA & 0.74 (INDICATIVE)
Duty Point 71.7 & 0.65
1.20.00 Stator winding
i) Connection Delta/Star
ii) Type & nos. of terminals Brought out 6
iii) Resistance between terminals at 20°C 1.08
iv) Resistance per phase at 20°C 18.86 ohm
 

Doc. No: DP16003‐YT01‐10HFB‐320001
JAWAHARPUR SUPER THERMAL POWER Rev‐05
STATION (2X660 MW) Date: 04‐03‐2020 1 of 5