G0k=0.226KN/m
G1k= 20*0.04*0.6+16*0.04*0.6+21*0.02*0.6+20*0.12*0.3+12*0.6
G1k= 9.036KN/m
3- Qk of live load:
Qk=10*0.6
Qk=6KN/m
- ULS
Fd=21.04KN/m
- SLS
Fd=15.262 KN/m
Mmax= 21.04*4.52/8
Mmax=53.26 KN.m
Vmax=21.04*4.5/2
Vmax=47.34KN
6- Reinforcement:
We have d=130mm
Mrdlim=591KN.m
X=63.68mm
Matricule : 16TP21136
As=1171.92mm2
So 3HA of diameter 25 mm on the base and 1 HA of diameter 32 mm on the top of the web
So, on the first 1.125m we have a spacement of 59mm between stirrups after we have a
spacement of 118 mm between 1.125m and 3.375m; after between 3.375m and 4.5m we
have a spacement of 59 mm between stirrups.