Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

Quality Control Services Testing Lab

RCC LAB LIMITED


House # 135,+880
Mobile: Road #05,New DOHS,
1922114868, Mohakhali
Phones: +88 02 Dhaka – 1206
8831751
Fax: +880-2-8920510
Email: info@rcclab.net, Web: www.rcclab.net

Sieve Analysis of Coarse Aggregates ASTM C136

RCC Ref no : RCC/sep01/19 Customer Ref no :


Name of Customer: Kashem Group Date of Sample received : 01.09.2019
Project: Montex Fabrics Condition on received:
Address: Konabari, Gazipur.

Wt. of Material (gm): 5000

Sieve Material
% Materials Cumulative %
Sieve Number Opening Retained % Finer FM
Retained Retained
(mm) (gm)
1 inch 25.4 62 1.24 1.24 98.76
3/4 inch 19.05 362 7.24 8.48 91.52
1/2 inch 12.5 3238 64.76 73.24 26.76
3/8 inch 9.5 1026 20.52 93.76 6.24
#4 4.75 286 5.72 99.48 0.52
#8 2.36 0 0 99.48 0.52
6.9926
#16 1.19 0 0 99.48 0.52
#30 0.59 0 0 99.48 0.52
#50 0.3 0 0 99.48 0.52
#100 0.15 7 0.14 99.62 0.38
Pan 19 0.38 100 0
Total 5000 100

Gradation Curve
120

100
% Material Passing

80

60 Column F

40

20

0
0 5 10 15 20 25 30
Partical Size, mm

Test Performed By Head of The Department


Curve Variation With Standard
120

100
% Material Passing

80
Lower Limit
60 Upper Limit
Material
40

20

0
0 5 10 15 20 25 30
Partical Size, mm

Test Performed By Head of The Department

You might also like