HemoCue® HbA1c 501 System

Designed to Work for Makes Your Whole Process Easier


How You Work and More Efficient
Only a few simple steps with clear
HemoCue HbA1c 501 is a fully automated
instructions on screen
point-of-care system that’s not only easy to use,
All-in-one, individually packaged
but every element – from its size to the storing and
cartridge kits
handling of cartridges – is thought through to be
Convenient room-temperature storage
ideally suited for how you work.
up to 18 months
Rigorously tested according to HemoCue principles,
and with automatic checks and calibrations built
Ensures You’ll Never Have to Doubt
into the system, you can count on getting the right an Answer at the Point of Care
answer at the right time – every time. Interference-free method unaffected
by Hb variants
So you won’t miss a beat in caring for your patients. IFCC and NGSP certified
Precise, fixed calibration by factory
Accuracy Starts With Us
Provides a Safe Workflow for
Excellent Patient Care
Automatic reading of calibration data for
each test cartridge lot
Barcode reader for patient and operator
ID available
Connectable
To learn more about HemoCue® HbA1c 501, please
scan the QR-code with your smartphone or visit
hemocue.com
HemoCue® HbA1c 501 System
Principle Fully automated boronate affinity assay HemoCue® HbA1c 501 accuracy
for determination of HbA1c percentage
in whole blood 100
y = 1.04x – 1.55

HbA1c 501 (mean) mmol/mol


90
r = 0.990
Calibration Factory calibrated and traceable to IFCC 80

and NGSP/DCCT 70

60

Sample Material Capillary or venous whole blood 50

40

Measurement 20 – 130 mmol/mol (IFCC), 30

Range 4.0 – 14.0 % (NGSP) 20

20 30 40 50 60 70 80 90 100 110

Results In 5 minutes Roche Cobas c501 (single replicate) mmol/mol

Sample Volume 4 µL Regression plot of venous blood, double sample,


for HemoCue HbA1c 501 versus Roche Cobas c501, n = 109.

Dimensions 198 × 217 × 136 mm
(7.80 × 8.54 × 5.35 inches) HemoCue® HbA1c 501 accuracy (total)
150
Weight 1,600 g (3.53 pounds)

HbA1c 501 (total mean), mmol/mol


y = 1.0014x – 0.0760
130
r = 0.9857
Storage Temp. Analyzer: 10  – 35 °C (50 – 95 °F) 110
Test Cartridge: unopened 2-32 °C
90
(36-90 °F)
70

Operating Temp. 17 – 32 °C (63 – 90 °F) 50 Venous


Capillary
30
Power 9 V DC / 1.5 A
10
10 30 50 70 90 110 130 150

Interface Printer, PC and Barcode Scanner Reference value, mmol/mol

Regression plot of total mean values for venous and capillary


Quality Control Built-in ”selftest”; Check Cartridge, system blood for HemoCue HbA1c 501 versus Tosoh G7.
can be verified using liquid controls

A few simple steps

lom/lomm 52 7.3% 562525


mmol
/mol
mmol/mol
mmol/mol 25 m
12.02.10
12.02.10 15:02
15:02
12.02.10
20:51 01.20.21 12.02.10
13.02.10
13.05.13 15:02
03:07

Insert the cartridge into the Prepare and apply the reagent Insert the reagent pack into The lab-quality result is
1 cartridge compa++rtment. 2 pack to the specimen. The 3 the cartridge. (Do not whipe 4 displayed automatically.
correct volume is drawn in by off excess blood outside the
GPM269INT 141124

capillary action. sampling area.)

HemoCue AB | PO Box 1204 | SE-262 23 Ängelholm | Sweden


Phone: +46 77 570 02 10  |  Fax: +46 77 570 02 12  |  info@hemocue.se  |  hemocue.com
© 2014 HemoCue AB  | HemoCue - part of the Radiometer Group
25 mmol/mol
HemoCue has been a leader in point-of-care medical diagnostics for over 30 years. 12.02.10 15:02
We specialize in giving healthcare providers lab-quality accuracy with results comparable
to that of a clinical lab.

You might also like