Background.........................................................................................................................................2
Tools Required for the Connectivity...................................................................................................3
Hardware Tools...........................................................................................................................3
Software package........................................................................................................................3
Installation of the software .........................................................................................................3
Connect Treadmill and Sampling Box to SE-1515.............................................................................4
Connection between Treadmill and Computer...........................................................................4
Connection between sampling box and computer......................................................................4
Verification of the Com Port Driver............................................................................................4
Verification of the Com Port Baud Rate.....................................................................................4
Configuration on SE-1515 Software...........................................................................................5
Verify the Connection via the Device Test Tool.................................................................................5
Tools Required for the Connectivity
Hardware Tools
PChwSEit-15 Treadmil
Software package
Find the file setup.exe in target folder and double click to install the software. A
shortcut SE-1515 can be found on the desktop after the installation.
Attention: The driver will be automatically installed during the installation of the software.
The user can find the driver packages in the target folder if the reinstallation is needed.
Connect the Treadmill to the AC power via power socket and turn on the main
power switch.
If the computer have the serial port socket:
Connect the treadmill to the computer directly via RS232 serial port cable.
If the computer doesn’t have the serial port socket:
Plug the serial port cable to treadmill via RS232 socket and connect the serial
port cable to the RS232-USB convert cable.
Connect the convert cable to the computer via USB socket.
Connect the sampling box directly to the computer via USB socket.
Attention: The SE-1515 supports 4 different models of sampling box: DP12, DX12 (wireless),
DE15, DE18.
Open Device Manager of the computer ( right click on the My PC icon, and
click the Manage ).
Check the device port ( COM10) under Serial Port (COM and LPT) and mark
it.
Attention:
If the devices cannot be found under Serial Port (COM and LPT), please check the cable and
connection again
If the devices port cannot be found, please check whether the divers are successfully installed.
If the communication failure window displayed after running software SE-1515 , please check
the cable again.
Open Device Manager of the computer ( right click on the My PC icon, and
click the Manage ).
Right click on the COM Port of treadmill, choose “Properties”, go into Port
Setting, modify the “Bits per second” option according to the treadmill model.
TM-400\TM-400(M) 9600
Trackmaster TMX428 4800
GE T2000 9600
Configuration on SE-1515 Software.
After connecting the treadmill and sampling box to the computer, the device model
and the device port of the treadmill and sampling box should be set correctly in the
System Setting of SE-1515. The setting of sampling box can be automatically set by
latest software version V1.42. However, the old version of software need to be set
manually.
Select the correct Device Model (DP12) and Device Port (COM3) of the
sampling box In Sampling Setting menu.
Select the correct Device Type (Treadmill), Device Model and Device Port
(COM10) in Device setup Treadmill/Ergometer menu.
You should be able to run a stress test now after all these above configurations
Verify the Connection via the Device Test Tool
Enter the Setting menu by click the icon on main user interface of SE-1515.
Click the Advanced Setting button under Other Setting submenu