SPEED CONTROLLER (SR CE TYPE)

1. Characteristics
·Speed controller SR series are developed by the demands of
speed variation.
·It uses the IC circuit that our company independently developed
and is small, light weight and reliability.
·With acquisition of CE Mark certification, the product guarantees
higher reliability.
·The rotating speed of the motor may be adjusted by a speed
control variable resistor located at the front of the case and can
also operate long-range by an extra speed setter.
·Increase of instantaneous stop function by electromagnetic brake
·Miniaturized type with 11pin plug
The product acguired CE mark ..
(File NO. E9766429E01 Certificate Institute: TUV Rhinland)
SPECIFICATIONS
MODEL SR CE TYPE

SPEC SRA01CE SRA02CE SRB01CE SRB02CE SRC01CE SRC02CE SRD01CE SRD02CE SRX01CE SRX02CE
Rated Voltage AC110V 60Hz AC220V 60Hz AC100V 50/60Hz AC200V 50/60Hz AC220~240V 50Hz
Operation Voltage Range ±10%
INDUCTION 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W
APPLICABLE
MOTOR REVERSIBLE 6W 15W~40W 6W 15W~40W 6W 15W~40W 6W 15W~40W 6W 15W~40W
※1
OUTPUT
E·S 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W
Speed control range 50Hz : 90~1400rpm 60Hz : 90~1700rpm
Speed variation 5%(standard)
Speed setting device Built in external speed setting device attachable
Braking Possible to stop for certain period by electric brake
※2 Braking period 0.5sec(standard)
Parallel operation Not suitable for parallel operation
Slow Run, Slow Stop none
Operation Temperature -10~50℃
Storage Temperature -20~60℃
Ambient humidity 85%Maximum(non condensing)
※1: Suitable motors are Socket Type Speed Control Motor of ours. (Use for 12V motor T.G)
※2: The electric brake does not have holding toque.

DIMENSIONS
▼ SR CE TYPE SPEED CONTROLLER 92
44 31
82.5 34 4 3.3
76
20
2
3.8

SRX01CE
HIGH
10

SPEED CONTROLLER
2- 5.2
0

LOW
VOLT 1Ph. 230V
SPEED
52MAX

FREQ. 50Hz
35.4

MAX.
25

1.2A
80

7
61

CURRENT
IP 2X
8

MADE IN KOREA

50 7

174 SPG
SCHEMATIC DIAGRAM
1-1 Uni Direction+Variable Speed 1-2 Uni Direction+Variable Speed+Brake

INDUCTION MOTOR (6W~90W) INDUCTION MOTOR (6W~25W)


REVERSIBLE MOTOR (6W~40W) REVERSIBLE MOTOR (6W~25W)
F1 OFF
2 POWER
ON
F1 OFF SOURCE
2 1
ON POWER SW1
SOURCE
1
SW1 4
4 RUN
SW2
7
7 BRAKE BLACK
R
10 5 10W GRAY
BLACK RUN MOTOR
SW3
10 WHITE 9 WHITE
MOTOR BRAKE
GRAY Ro Co
9
CAPACITOR
RED T.G
5
CAPACITOR RED
RED T.G 6
5
RED AC125V
6 11 SW1, 3 or AC250V
MIN. 5A
PIN NO.
11 AC125V
F1 or AC250V
3A
PIN NO.
▲For wiring of 220V-240V, 50Hz SW2 DC 20V 10mA
AC 125V motor, change gray to brown. Ro=10~200Ω(MIN. 1/4W)
SW1 or AC 250V MIN. 5A ▲For wiring of 220V-240V, 50Hz
Ro,Co Co=0.1~0.2㎌
motor, change gray to brown. (AC125WV ,AC250WV)
F1 AC 125V 3A
or AC 250V Note) R 4.7Ω~6.8Ω MIN. 10W

Note) 1. The motor rotating direction is CW when viewed from output shaft.
1. The motor rotating direction is CW when viewed from output shaft. When adjusting to CCW, change and connect white and
When adjusting to CCW, change and connect white and gray wire gray wire of motor.
2. When switched from Run to Stop, electric brake will function about
of motor.
0.5 sec. and motor will come to stop instantaneously.
2. The connection of a fan motor is applicable only if the output of
BRAKE BRAKE
the motor is greater than 60W and refer to page 175 for the
connection method. ◆ Example of operation SW1
RUN STOP RUN STOP

SPEED CONTROLLER/CONTROL MOTORS


ON
RUN STOP
◆ Example of operation SW1
ON OFF
SW2
SW3 STOP STOP
RUN RUN
MOTOR
CW MOTOR
CW CW

1-3 Uni Direction+Variable Speed+Brake


Note)
F1 OFF 1. The motor rotating direction is CW when viewed
2 ON POWER from output shaft. When adjusting to CCW,
SOURCE
1 change and connect white and gray wire of motor.
SW1
▲For wiring of 220V-240V, 50Hz 2. When switched from Run to Stop, electric brake will
4 motor, change gray to brown. function for 0.5sec. and motor will come to stop
RUN instantaneously.
SW2
7 AC125V 3. The connection of a fan motor is applicable only if
BRAKE
WHITE
SW1, 3 or AC250V
MIN. 5A the output of the motor is greater than 60W and
10 R
5 10W
GRAY AC125V refer to page 175 for the connection method.
SW3
RUN MOTOR F1 or AC250V
3A
9
BRAKE
BLACK
SW2 DC 20V 10mA ◆ Example of operation
CAPACITOR
Ro Co
Ro=10~200Ω(MIN. 1/4W) BRAKE BRAKE

5 RED T.G Ro,Co Co=0.1~0.2㎌


SW1
RUN STOP RUN STOP

RED
(AC125WV ,AC250WV) ON
6 R 4.7Ω~6.8Ω MIN. 10W SW2
SW3 RUN STOP RUN STOP
11
MOTOR
PIN NO. CW CW

Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)

SPG 175
2-1 Reverse+Variable Speed 2-2 Reverse+Variable Speed+Brake

INDUCTION MOTOR(6W~90W) INDUCTION MOTOR (6W~25W)


REVERSIBLE MOTOR (6W~40W) REVERSIBLE MOTOR(6W~25W)
F1 OFF
2 F1 OFF
ON POWER
SOURCE
2 POWER
1 ON
SOURCE
SW1 1
4 SW1
4
RUN
7 SW2
7
BRAKE
R
BLACK 5 10W CW BLACK
10
RUN WHITE
10 CW WHITE SW5 SW4
SW2 MOTOR CCW MOTOR
GRAY 9 Ro Co GRAY
BRAKE
9 CCW Ro Co
CW
SW3
CAPACITOR CAPACITOR
RED T.G CCW T.G
Ro Co
5 RED
RED 5
6 RED
6
11
11 AC125V
PIN NO. SW1,3,4,5 or AC250V
MIN. 5A
PIN NO.
AC125V
AC 125V F1 or AC250V
3A
▲For wiring of 220V-240V, 50Hz SW1 or AC 250V MIN. 5A ▲For wiring of 220V-240V, 50Hz
motor, change gray to brown. SW2 DC 20V 10mA
F1 AC 125V 3A motor, change gray to brown. Ro=10~200Ω(MIN. 1/4W)
or AC 250V Ro,Co Co=0.1~0.2㎌
Note) (AC125WV ,AC250WV)
1. Set“Stop”period for induction motor and switch SW2 after rotation R 4.7Ω~6.8Ω MIN. 10W
Note)
has stopped.
1. When switched from Run to Stop, electric brake will function for
2. Reversible Motor does not need“Stop”period. It has no relation
0.5sec. and motor will come to stop instantaneously
operating SW2 when SW1 is on.
2. Do not operate SW4, SW5 for this 0.5 sec.
3. The connection of a fan motor is applicable only if the output of
3. Changing period of SW4, SW5 should be done quicker than Stop
the motor is greater than 60W and refer to page 178 for the
to Run of SW2, SW3
connection method. BRAKE BRAKE
◆ Example of operation FORWARD
STOP REVERSE STOP
◆ Example of operation FORWARD STOP REVERSE
SW1 ON
SW1 SW2
ON ON
SW5
RUN STOP RUN STOP
SW2 CW SW3
SW4 CW CW
CCW
CCW

2-3 Reverse+Variable Speed+Brake

INDUCTION MOTOR (40W~90W) Note)


REVERSIBLE MOTOR (40W) 1. When switched from Run to Stop, electric brake will function for
F1 OFF
0.5sec. and motor will come to stop instantaneously
2
ON POWER 2. Do not operate SW4, SW5 for this 0.5 sec.
1
SOURCE ▲For wiring of 220V-240V, 3. Changing period of SW4, SW5 should be done quicker than
SW1 50Hz motor, change gray Stop to Run of SW2, SW3
to brown. 4. The connection of a fan motor is applicable only if the output
4 Ro Co

SW2
RUN of the motor is greater than 60W and refer to page 178 for the
7 SW4
CW
connection method.
BRAKE WHITE
10 Ro Co
CCW
GRAY SW1,3,4,5 AC125V
MIN. 5A
◆ Example of operation
RUN MOTOR or AC250V
SW5 R CW BRAKE BRAKE
5 10W BLACK
9 AC125V FORWARD STOP REVERSE STOP
BRAKE
Ro Co SW3 CCW
CAPACITOR F1 or AC250V
3A SW1 ON

RED T.G SW2 DC 20V 10mA SW2


SW5
5 Ro=10~200Ω(MIN. 1/4W) RUN STOP RUN STOP
RED
6 Ro,Co Co=0.1~0.2㎌ SW3
SW4
(AC125WV ,AC250WV) CW CW
11 CCW

PIN NO.
R 4.7Ω~6.8Ω MIN. 10W

Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)

176 SPG
3-1 External speed setting device 3-2 For prompt start(1)

When Distance Control is Necessary ▼ Without braking

F1 OFF ※ When starting of motor is slow while starting signal is input at Run
2
ON POWER
SOURCE
switch(SW1), use external volume VR at SW2 for Run/Stop.
1
SW2 STOP Speed control
SW1
Potentiometer
2
RUN 20㏀

4 3 1 F1 OFF
2
7 External speed setting device ON POWER
SOURCE
(20㏀ 1/4WB) 1
STOP SW1
SW2

11 2 Speed control potentiometer


Insulated RUN 20㏀
PIN NO. Twisted sealed wire Wire Internal seal 4
External seal 3 1

7
11
External speed setting device to No. 2 pin of the socket PIN NO.

Note)
1. Set the volume to‘LOW’.
2. Shorten the connection cable as much as possible May cause
◆ Example of operation
faulty action. In such case use twist shield cable and connect it to
Min. 0.5sec
No.2 terminal. RUN STOP RUN
SW1
ON

When Multi-Stage Speed Setting is Necessary SW6


STOP RUN STOP RUN

F1 OFF
2 POWER
ON
SOURCE
1
SW1 Note)
1. Input time of SW1 should be about 0.5sec quicker than starting
VR1 1 VR2 1 VR3 1
signal of SW2.
2
2 2 2. Set the volume“LOW”and use external volume VR to control

SPEED CONTROLLER/CONTROL MOTORS


3 3 3
RUN
4 SW4 speed.
7
STOP
3. During Run/Stop operation, control SW2 while SW1 is on.
PIN NO. Even with small signal motor can be controlled.
SWA SWB SWC
4. When not in use for long period turn SW1 off.

Note)
1. Set the volume to‘LOW’.
2. If multi-stage speed control is needed, install VR1, VR2, and VR3
respectively and the speed can be changed by SWA, SWB,
and SWC. The open/close time of the switch is advised to
follow the open/close time of the relay contact point.

Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)

SPG 177
3-3 For prompt start(2) 3-4 Box fan motor connection method

▼ With Braking

INDUCTION MOTOR(6W~25W)
REVERSIBLE MOTOR (6W~25W) 2
F1 OFF

ON POWER
OFF SOURCE
1
2 POWER
SW1
ON
SOURCE PIN NO.
1
STOP SW1
SW6
Speed control
2
potentiometer
RUN RUN 20㏀ BLACK
SW7

{
3 3 1
MOTOR WHITE
BRAKE
GRAY MOTOR
6
RED
8
7
SW5
RUN
R
5 10W
BLACK
GRAY
T.G
{ RED
T.G

‘B’ FAN
BRAKE MOTOR
Ro Co WHITE ‘B’

CAPACITOR RED T.G


4
RED
5
PIN NO. VOLTAGE LEAD WIRE COLOR‘B’
SINGLE PHASE
AC100V~110V BROWN
AC125V
SW1, 5 or AC250V
MIN. 5A SINGLE PHASE
AC 200V~240V YELLOW
AC125V
F1 or AC250V
3A
▲For wiring of 220V-240V, 50Hz
SW6, 7 DC 20V 10mA
motor, change gray to brown.
Ro=10~200Ω(MIN. 1/4W) ▲For wiring of 220V-240V, 50Hz
Ro,Co Co=0.1~0.2㎌ motor, change gray to brown.
(AC125WV ,AC250WV)
R 4.7Ω~6.8Ω MIN. 10W

◆ Example of operation ※ For the connection of something other than the box
Min. 0.5sec
BRAKE BRAKE fan, refer to the electrical wiring diagram for the
SW1
RUN STOP RUN STOP
corresponding connection.
ON

SW6 STOP RUN


SW5
SW7 RUN STOP RUN STOP

Note)
1. This wiring is for unidirection+Variable speed+braking of motors
25W or less. For motors 40W and over part of wiring is
different. Refer to the electrical wiring diagram for the corresponding
connection.
2. Input time of SW1 should be about 0.5sec quicker than SW6.
3. Set the volume“LOW”and use external volume VR to control speed.
4. When not in use for long period turn SW1 off.

Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)

178 SPG
4-1 Wire connection for electromagnetic brake motor 4-2 Wire connection for electromagnetic brake motor

When electric brake of controller is used at the same time When electric brake of controller is used at the same time

E.S MOTOR (6W~25W) E.S MOTOR (40W~90W)


F1 OFF
F1 OFF
2 POWER 2
ON POWER
1 Ro Co
SOURCE ▲For wiring of 220V-240V, 1
ON
SOURCE ▲For wiring of 220V-240V,
ELECTROMAGNETIC
SW1
50Hz motor, change gray Ro Co SW1 50Hz motor, change gray
4 BRAKE to brown. ELECTROMAGNETIC
BRAKE to brown.
RUN SW6 4 Ro Co
RUN SW6
SW2 R
CW RUN BLACK SW2 RUN WHITE
7 BRAKE 5 10W
7 CW
WHITE SW3
SW3 BRAKE GRAY
10
RUN
Ro Co
CCW
GRAY MOTOR VOLTAGE LEAD WIRE‘A’ 10 Ro Co CCW
BLACK MOTOR VOLTAGE LEAD WIRE‘A’
SW5 ‘A’ RUN R
CW SW5 CW
9 ELECTROMAGNETIC SINGLE PHASE 9 5 10W
CAPACITOR
‘A’ SINGLE PHASE
BRAKE CAPACITOR ‘A’
BRAKE AC100V~110V Blue BRAKE ELECTROMAGNETIC Blue
Ro Co SW4
CCW Ro Co SW4 CCW
‘A’
BRAKE AC100V~110V
Ro Co
RED T.G SINGLE PHASE SINGLE PHASE
5 AC200V~240V Orange 5
RED T.G Orange
RED AC200V~240V
6 RED
6
11 11
PIN NO.
◆ Example of operation PIN NO.
◆ Example of operation
AC125V AC125V
SW1,3,4,5,6 MIN. 5A SW1,3,4,5,6 or AC250V
MIN. 5A
or AC250V BRAKE
FORWARD
BRAKE
REVERSE
BRAKE
FORWARD
BRAKE

AC125V
STOP STOP
AC125V STOP REVERSE STOP

F1 3A
SW1 ON
F1 or AC250V 3A SW1 ON

or AC250V SW2
Min. 0.5sec
SW2
Min. 0.5sec

SW2 DC 20V 10mA SW5 RUN STOP RUN STOP


SW2 DC 20V 10mA SW5 RUN STOP RUN STOP

Ro=10~200Ω(MIN. 1/4W) SW6


Min. 0.5sec
STOP STOP
Ro=10~200Ω(MIN. 1/4W) SW6
Min. 0.5sec
STOP STOP
RUN RUN RUN RUN

Ro,Co Co=0.1~0.2㎌ SW3 Ro,Co Co=0.1~0.2㎌ SW3

(AC125WV ,AC250WV)
SW4 CW CW (AC125WV ,AC250WV) SW4 CW CW
CCW CCW

R 4.7Ω~6.8Ω MIN. 10W R 4.7Ω~6.8Ω MIN. 10W


Note)
Note) 1. When switched from Run to Stop, electromagnetic brake will
1. When switched from Run to Stop, electromagnetic brake will function for about 0.5sec. and motor will come to stop instantaneously.
function for about 0.5sec. and motor will come to stop instantaneously. 2. Operate SW3, SW4 after the motor has stopped.
2. Operate SW3, SW4 after the motor has stopped. 3. Changing period of SW3, SW4 should be done quicker than stop to
3. Changing period of SW3, SW4 should be done quicker than stop to run run of SW2, SW5, SW6.
4. Power input for SW1 should be more than 0.5sec. quicker than
of SW2, SW5, SW6.
starting signals of SW2, SW5&SW6.
4. Power input for SW1 should be more than about 0.5sec. quicker than 5. When Run/Stop, operate with SW2, SW5, SW6 while SW1 is On
starting signals of SW2, SW5, SW6. condition. Even with small signal it can control the motor. Turn SW1 off

SPEED CONTROLLER/CONTROL MOTORS


5. When Run/Stop, operate with SW2, SW5, SW6 while SW1 is‘On’ when not used for long period.
condition. Even with small signal it can control the motor. Turn SW1 off 6. The connection of a fan motor is applicable only if the output of the
when not used for long period. motor is greater than 60W and refer to page 178 for the connection
method.

4-3 Wire connection for electromagnetic brake motor


When electric brake of controller is used at the same time
F1 OFF
2
1
ON POWER
SOURCE E.S MOTOR (6W~90W) VOLTAGE LEAD WIRE‘A’
STOP SW1
Blue
SW2
Speed control
Ro Co
SINGLE PHASE AC100V~110V
2 potentiometer
ELECTROMAGNETIC
RUN 20㏀ BRAKE
◆ Example of operation SINGLE PHASE AC200V~240V Orange
4 3 1
SW4
Ro Co RUN BLACK ▲For wiring of 220V-240V,
7 AC125V
10 CW WHITE 50Hz motor, change gray FORWARD STOP REVERSE STOP SW1,3,4 or AC250V
MIN. 5A
GRAY MOTOR to brown. SW1 ON
SW3 AC125V
9 Ro Co CCW ‘A’
ELECTROMAGNETIC SW4
Min. 0.5sec
STOP STOP
F1 or AC250V
3A
CAPACITOR RUN RUN
‘A’ BRAKE
RED
Min. 0.5sec SW2 DC 20V 10mA
SW2
5 T.G RUN STOP RUN STOP Ro=10~200Ω(MIN. 1/4W)
RED
6
SW3
Ro,Co Co=0.1~0.2㎌
CW CW
11 CCW
(AC125WV ,AC250WV)
PIN NO.

Note 3. When Run/Stop, operate with SW2, SW4 while SW1 is on. Even with small signal it
1. Set the stop period to stop and convert to SW2 after rotation has stopped. can control the motor Turn SW1 off when not used for long period.
2. Input period for power switch SW1 should be about 0.5sec. quicker than the 4. Set the volume low and control the speed with external speed setting device VR.
signal of start operating of SW6, SW9. 5. The connection of a fan motor is applicable only if the output of the motor
is greater than 60W and refer to page 178 for the connection method.
Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)

SPG 179
SPEED CONTROLLER (SOCKET SS HIGH OUTPUT TYPE)
●SOCKET SS TYPE (HIGH OUTPUT)
Used for induction speed control motors of 6W∼90W, reversible speed
control motors of 6W~40W and electromagnetic brake speed control
motors of 6W~40W.
Built-in speed setting device on the case enables to control and set
the speed of motors.
Instantaneous stop function is possible by electric brake.
It is a compact plug-in type with 11pins so it is easy to set and use.
It has slow run and slow stop functions, so operating and braking
are not working rapidly, instead slowly.
There is time (period) setting device installed to control easily slow
run and slow stop function.
Parallel operation is possible.
※Parallel operation means that with one speed control volume,
▼ SPECIFICATIONS It can control plural speed controller at same time at same speed.

MODEL SS TYPE

SPEC SSA03-SRSS SSB03-SRSS SSC03-SRSS SSD03-SRSS SSX03-SRSS

Rated Voltage SINGLE-PHASE AC110V SINGLE-PHASE AC220V SINGLE-PHASE AC100V SINGLE-PHASE AC200V SINGLE-PHASE AC220V~240V

Operation Voltage Range ±10%

Power Source Frequency 60Hz 50/60Hz 50Hz

Rated Current 3.0A

Induction 6W~90W 6W~90W 6W~90W 6W~90W 6W~90W


APPLICABLE
※1 MOTOR Reversible 6W~40W 6W~40W 6W~40W 6W~40W 6W~40W
OUTPUT
E S 6W~40W 6W~40W 6W~40W 6W~40W 6W~40W
Speed control range 90~1700rpm 90~1400rpm/90~1700rpm 90~1400rpm

Speed variation 5%(standard)

Speed setting device Built in external speed setting device attachable

Braking possible to stop for certain period by electric brake

※2 Braking period 0.5sec (standard)

Parallel operation Possible

Slow Run, Slow Stop Possible(0.5sec∼15sec/1200rpm)

Operation Temperature -10℃∼50℃

Operation humidity 85%Max (non condensing)

Storage Temperature -20℃∼60℃


100㏁ or more when 500V megger is applied between the pin and the
Insulation resistance housing at ambient temperature and humidity
No abnormality after input of 1500V 50/60㎐ between the pin and the
Dielectric strength housing at ambient temperature and humidity for 1min
※1.: Applicable motors are socket type control motors of SPG. (Use for 24V motor T.G)
※2.: There are no holding toque on electric brake.

194 SPG
DIMENSIONS
SS TYPE (HIGH OUTPUT) SPEED CONTROLLER
92
▼ CONTROL PACK 82.5
44
76

SSBO3-SRSS
SLOW RUN 6
5 7
HIGH
10

CONTROL PACK 4 8
0

LOW

80

70
61

VOLT 1Ph. 220V 3 9


FREQ. 60Hz SLOW STOP

8
2 10
MAX. HIGH
CURRENT 3A
10

1 11
0

LOW

MADE IN KOREA

50

▼ 11PIN SOCKET
7.8

4
11-M3.5 L7

5 4

(118)
(81)

35.4
2 - 4.577HOLE
4

SPEED CONTROLLER/CONTROL MOTORS


0.2
40

(33.5)
(50)

▼ VARIABLE RESISTOR 20㏀ 1/4W

40MIN
13 20
M4 P0.7 L6
0.4 * *
Fixed screw
0.2
40

0.5
10
0
R3
12.5
3
40

24

24

0.2
40

0.2 9.5
3.2

Handle
Potentiometer
Panel( 40)
0.2
Insulator( 40)
Insulator

SPG 195
SCHEMATIC DIAGRAM(INDUCTION MOTOR)
1-1 Uni Direction+Variable Speed (6W-90W)

OFF ▲For wiring of 220V-240V, 50Hz


10 motor, change gray to brown.
ON POWER
SOURCE
2
STOP SW1
SW2
2 SW1 AC125V or AC 250V MIN. 5A
RUN Speed control potentiometer
20㏀
8
SW2 DC 20V 10mA
3 1
Note)
9
1. The motors, rotating direction is CW when viewed from output shaft.
7 When adjusting to CCW direction, exchange white wire to gray.
BLACK 2. The connection of a fan motor is applicable only if the output of the
6
motor is greater than 60W and refer to page 202 for the
WHITE
3 MOTOR connection method.
GRAY
4
CAPACITOR
◆ Example of operation
RED T.G SLOW RUN STOP
RUN RUN
1 SW1
STOP STOP SLOW STOP
ON
RED
11
SW2 RUN STOP RUN STOP RUN STOP
PIN NO.

MOTOR
CW CW CW

1-2 Uni Direction+Variable Speed+Brake (6W~25W)

SW1,4 AC125V MIN. 5A


OFF
or AC 250V
10
ON POWER
SW2,3 DC 20V 10mA
SOURCE Ro=10~200Ω(MIN. 1/4W)
2
SW2 STOP SW1
Ro,Co Co=0.1~0.2㎌
2
Speed control (AC125WV, AC250WV)
RUN potentiometer ▲For wiring of 220V-240V, 50Hz
8 20㏀ motor, change gray to brown. R: Braking 10Ω, MIN. 10W
3 1 external
9 resistor
7 Note)
RUN
SW3 1. The motor rotating direction is CW when viewed from output shaft
6 BLACK When adjusting to CCW direction, exchange white wire to gray.
STOP
5 WHITE
MOTOR
3 RUN R GRAY
4
SW4
STOP
10 10W ◆ Example of operation
Ro Co BRAKE
BRAKE
SLOW RUN SLOW RUN STOP
CAPACITOR RED T.G RUN STOP RUN STOP SLOW STOP STOP SLOW STOP
1 SW1 ON
RED
11
SW2 RUN STOP RUN STOP RUN STOP
PIN NO. SW3
SW4 RUN BRAKE RUN BRAKE

MOTOR
CW CW CW CW

196 SPG
1-3 Uni Direction+Variable Speed+Brake (40W~90W)

OFF
10 POWER
ON
SOURCE
2 ▲For wiring of 220V-240V, 50Hz
SW2 STOP SW1 motor, change gray to brown.
2 Speed control
RUN potentiometer
20㏀
8 3 1

9 AC125V
SW1,4 MIN. 5A
7 or AC 250V
6
SW3 RUN
SW2,3 DC 20V 10mA
BLACK Ro=10~200Ω(MIN. 1/4W)
STOP
5 WHITE Co=0.1~0.2㎌
MOTOR Ro,Co
3 GRAY (AC125WV, AC250WV)
RUN R
SW4
4 STOP
10 10W
R: Braking
Ro Co external 10Ω, MIN. 10W
CAPACITOR RED T.G resistor
1
RED
11
PIN NO.

◆ Example of operation
BRAKE
BRAKE
SLOW RUN SLOW RUN
RUN STOP RUN STOP SLOW STOP STOP SLOW STOP STOP
SW1 ON

SW2
Note) RUN STOP RUN STOP RUN STOP
SW3
1. The motor’s rotating direction is CW when viewed from output shaft.

SPEED CONTROLLER/CONTROL MOTORS


SW4 RUN BRAKE RUN BRAKE
When adjusting to CCW direction, exchange white wire to gray.
MOTOR
2. The connection of a fan motor is applicable only if the output of the CW CW CW CW

motor is greater than 60W and refer to page 202 for the
connection method.

▼ Method of Use (INDUCTION MOTOR)


● Run/Stop function
If SW2 is switched to“RUN”as section 1-1,2,3, the motor will rotates as per
fixed speed set by external speed controller when switched to“STOP”
rotation will come to spontaneous stop by inertia force.

● Run/Brake function
If SW3 and SW4 is turned to stop while SW2 is on RUN condition, the brake
will function for about 0.5 seconds and stop the motor instantaneously.

● Slow Run/Slow Stop function


When SW2 is switched to Run/Stop after slow run, slow stop is set by the volume of controller,
the motor will slowly start and slowly stop as per set time.
The speed of slow run and slow stop changes in rectilinearly against set time and the slope can be
controlled within 0.5sec∼15sec/1200rpm.
Slow stop is not possible to be set for shorter period than natural stopping period of motor.
※ Turn SW1 off to prevent control pack from generating heat when not used for a long period.

SPG 197
SCHEMATIC DIAGRAM(INDUCTION MOTOR)
2-1 Reverse+Variable Speed (6W~40W)

▲For wiring of 220V-240V, 50Hz


OFF motor, change gray to brown.
10
ON POWER
SOURCE
2 AC125V
SW2 STOP SW1 SW1,3 or AC 250V MIN. 5A
2 Speed control
SW2 DC 20V 10mA
RUN potentiometer
20㏀ Ro=10~200Ω(MIN. 1/4W)
8 3 1

9 Ro Co
Ro,Co Co=0.1~0.2㎌
BLACK (AC125WV, AC250WV)
3 CW WHITE
SW3 MOTOR
4 GRAY
CCW
Ro Co
7
6
CAPACITOR
T.G
◆ Example of operation
SLOW RUN
RUN STOP RUN STOP SLOW STOP STOP
SW1 ON
RED
1 SW2 RUN STOP RUN STOP RUN STOP
RED
11 SW3 CW CCW CW
PIN NO. MOTOR CW CW
CCW

2-2 Reverse+Variable Speed+Brake (6W~25W)

▲For wiring of 220V-240V, 50Hz


motor, change gray to brown.
OFF
10
ON POWER
2 SOURCE
SW1,4,5,6 AC125V MIN. 5A
or AC 250V
SW2 STOP SW1
2 Speed control potentiometer
SW2,3 DC 20V 10mA
RUN
20㏀ Ro=10~200Ω(MIN. 1/4W)
8 Co=0.1~0.2㎌
3 1 Ro Co BLACK Ro,Co
9 (AC125WV, AC250WV)
CW WHITE
7 SW5 MOTOR R: Braking
RUN GRAY external 10Ω, MIN. 10W
SW3
6 CCW resistor
Ro Co
STOP
5
SW6
CW
T.G
◆ Example of operation
3 RUN R
SW4 10 10W
BRAKE
SLOW RUN SLOW RUN
BRAKE

4 STOP CCW
CAPACITOR RUN STOP RUN STOP SLOW STOP STOP SLOW STOP STOP
Ro Co SW1 ON

RED SW2 RUN STOP RUN STOP RUN STOP


1 SW3
RED SW4 RUN BRAKE RUN BRAKE
11 SW5
SW6 CW CCW CW
CW
PIN NO.
MOTOR CW CW CW
CCW

198 SPG
2-3 Reverse+Variable Speed+Brake (40W)

▲For wiring of 220V-240V, 50Hz


motor, change gray to brown.

OFF
10 SW1,4,5,6 AC125V MIN. 5A
ON POWER or AC 250V
SOURCE
2 SW2,3 DC 20V 10mA
STOP SW1
SW2 Ro=10~200Ω(MIN. 1/4W)
2
Speed control
RUN potentiometer Ro,Co Co=0.1~0.2㎌
8 3 1
20㏀
Ro Co
(AC125WV, AC250WV)
BLACK
9 R: Braking 10Ω, MIN. 10W
CW WHITE
7 SW5 MOTOR external
RUN GRAY resistor
SW3
6 CCW
Ro Co
STOP
5 CW
SW6 T.G
3 RUN R
SW4
4 STOP 10 10W CCW
CAPACITOR
◆ Example of operation
Ro Co
BRAKE BRAKE
SLOW RUN SLOW RUN
RED RUN STOP RUN STOP SLOW STOP STOP SLOW STOP STOP
1 SW1 ON
RED
11 SW2 RUN STOP RUN STOP RUN STOP
PIN NO. SW3
SW4 RUN BRAKE RUN BRAKE
SW5
SW6 CW CCW CW
CW

MOTOR CW CW CW
CCW

SPEED CONTROLLER/CONTROL MOTORS


▼ Method of Use (INDUCTION MOTOR)
● Run/Stop function
If SW2 is switched to“RUN”as section 2-1,2,3, the motor will rotate as per
fixed speed set by external speed controller when switched to“STOP”
rotation will come to spontaneous stop by inertia force.

● Run/Brake function
If SW3 and SW4 is turned to stop while SW2 is on RUN condition, the brake
will function for about 0.5 seconds and stop the motor instantaneously.

● Slow Run/Slow Stop function


When SW2 is switched to Run/Stop after slow run, slow stop is set by the volume of controller,
the motor will slowly start and slowly stop as per set time.
The speed of slow run and slow stop changes in rectilinearly against set time and the slope
can be controlled within 0.5sec∼15sec/1200rpm.
Slow stop is not possible to be set for shorter period than natural stopping period of motor.
※ Turn SW1 off to prevent control pack from generating heat when not used for a long period.

SPG 199
SCHEMATIC DIAGRAM (E.S MOTOR)
3-1 Reverse+Variable Speed (6W~40W)

SW1,3,7 AC125V MIN. 5A


or AC 250V
SW2 DC 20V 10mA
OFF Ro=10~200Ω(MIN. 1/4W)
10
ON POWER
SOURCE
Ro,Co Co=0.1~0.2㎌
2 Ro Co (AC125WV, AC250WV)
SW2 STOP SW1
2 Electromagnetic
Speed control Brake
RUN potentiometer VOLTAGE LEAD WIRE‘A’
8 20㏀ SW4 RUN ▲For wiring of 220V-240V, 50Hz
3 1
motor, change gray to brown. SINGLE PHASE
AC100V~110V Blue
9 Ro Co BLACK
SINGLE PHASE
3 AC200V~240V Orange
CW WHITE
SW3
4 GRAY MOTOR ◆ Example of operation
7 Ro Co CCW ‘A’
BRAKE BRAKE SLOW RUN BRAKE MOTOR
CAPACITOR Electromagnetic RUN HOLDING RUN HOLDING SLOW STOP HOLDING FREE
6 ‘A’ Brake
SW1 ON

T.G SW2 RUN STOP RUN STOP RUN STOP


RED
1 SW3 CW CCW CW
RED
11 SW4
SW4 RUN BRAKE RUN BRAKE RUN BRAKE
PIN NO.
MOTOR CW CW
CCW

3-2 Reverse+Variable Speed+Brake (6W~25W)

VOLTAGE LEAD WIRE‘A’ SW1,4,5,6,7 AC125V MIN. 5A


or AC 250V
SINGLE PHASE SW2,3 DC 20V 10mA
OFF
AC100V~110V Blue
10 Ro=10~200Ω(MIN. 1/4W)
ON POWER
SINGLE PHASE
2 SOURCE Orange Co=0.1~0.2㎌
SW1
AC200V~240V Ro,Co
SW2 STOP Ro Co
(AC125WV ,AC250WV)
2 Speed control
RUN potentiometer
Electromagnetic
Brake ▲For wiring of 220V-240V, 50Hz R: Braking
motor, change gray to brown. 10Ω, MIN. 10W
8 20㏀
Ro Co
external
3 1 SW7 RUN BLACK resistor
9 CW WHITE
7 SW5
GRAY MOTOR
SW3 RUN ◆ Example of operation
6 Ro Co
CCW
‘A’
STOP BRAKE BRAKE
5 CW ‘A’ Electromagnetic
Brake BRAKE SLOW RUN BRAKE SLOW RUN BRAKE
SW6 BRAKE
RUN HOLDING RUN HOLDING SLOW STOP HOLDING SLOW STOP HOLDING
3 RUN R SW1
SW4 CCW T.G ON
4 STOP10 10W
Co CAPACITOR
Ro SW2 STOP STOP STOP
RUN RUN RUN
RED SW3
BRAKE BRAKE
1 SW4 RUN RUN
RED SW5
11 SW6 CW CCW CW

PIN NO. SW7 RUN RUN RUN RUN

MOTOR CW CW CW
CCW

200 SPG
3-3 Uni Direction+Variable Speed+Brake (40W)

◀ For wiring of 220V-240V


motor, change gray to brown.
OFF
10 VOLTAGE LEAD WIRE‘A’
ON POWER
SOURCE
2 SINGLE PHASE
SW2 STOP AC100V~110V Blue
Ro Co
2
SINGLE PHASE
RUN Speed control Electromagnetic
Brake AC200V~240V Orange
potentiometer
8 3 1
20㏀
Ro Co
SW7 RUN
AC125V MIN. 5A
9 CW WHITE
SW1,4,5,6,7 Or AC 250V
7 SW5
RUN GRAY SW2,3 DC20V 10mA
SW3
6 Ro Co CCW
Ro=10~200Ω(MIN. 1/4W)
BLACK MOTOR
5 STOP
Ro,Co Co=0.1~0.2㎌
CW ‘A’
SW6 (AC125W ,AC250WV)
3 RUN R ‘A’ Electromagnetic
SW4 10 10W CCW
Brake R:Braking
4 STOP external 10Ω, MIN. 10W
Ro Co
CAPACITOR
resistor
T.G
RED
1
RED
11 ◆ Example of operation
PIN NO. BRAKE BRAKE
BRAKE BRAKE SLOW RUN BRAKE SLOW RUN BRAKE
RUN HOLDING RUN HOLDING SLOW STOP HOLDING SLOW STOP HOLDING
SW1 ON

SW2 RUN STOP RUN STOP RUN STOP


SW3
SW4 RUN BRAKE RUN BRAKE
SW5
SW6 CW CCW CW
SW7 RUN RUN RUN RUN

SPEED CONTROLLER/CONTROL MOTORS


MOTOR CW CW CW
CCW

▼ Method of Use (E·S MOTOR)


● Run/Stop function
If SW2 is switched to“RUN”as section 3-1,2,3, the motor will rotate as per
fixed speed set by external speed controller when switched to“STOP”
rotation will come to spontaneous stop by inertia force.

● Run/Brake function
If SW3 and SW4 is turned to stop while SW2 is on RUN condition, the brake
will function for about 0.5 seconds and stop the motor instantaneously.

● Slow Run/Slow Stop function


When SW2 is switched to Run/Stop after slow run, slow stop is set by the volume of controller,
the motor will slowly start and slowly stop as per set time.
The speed of slow run and slow stop changes in rectilinearly against set time and the slope can be
controlled within 0.5sec∼15sec/1200rpm.
Slow stop is not possible to be set for shorter period than natural stopping period of motor.
※Turn SW1 off to prevent control pack from generating heat when not used for a long period.

SPG 201
APPLICATION OF SCHEMATIC DIAGRAM
▼ Parallel operation ▼ Usage(Parallel operation)

SS TYPE high output controller can control speed of multiple motors using Connect power supply line(Terminal No. ②,⑩)& control
one variable resistor as per following diagram at same speed. line (Terminal No. ⑧, ⑨) for same line like the side
wiring. In case of other motor and control pack, set
power line and control line for parallel operation.

6 7
10
CONTROL PACK
9 △! Warning
Connect to correct pin numbers for power line and
2 8 control line.
3 4 1 11 SVR

The capacity of variable resistor for speed setting


is calculated in following way.
VRX=20/N ㏀, N/4W(N: Quantity of motor)
eg) For 2EA of motors, it is 10㏀ 1/2W
BLACK
WHITE
GRAY

RED
RED

CAPACITOR
Although every motor runs at almost same speed,
there could be slight error due to difference of load
P MOTOR T C
O
and variation of products. To prevent this
O G
W N
T
phenomenon, prepare 5-10% of resistance and 1/4
E
R R
O
capacity of VR×(Variable resistance for speed
L L
setting)with SVR(Variable resistor for precise
I L
N I control) of terminal ⑧.
E N
6 7 E

10 9
CONTROL PACK
2 8
3 4 1 11
BLACK
WHITE
GRAY

RED
RED

CAPACITOR
3

SW2 VRx ▲For wiring of 220V-240V, 50Hz


T 2
MOTOR G motor, change gray to brown.
STOP RUN 1

▼ Connection Method for BOX FAN MOTOR

OFF
10 POWER
ON
SOURCE
2
SW1
PIN NO.
VOLTAGE LEAD WIRE COLOR‘B’
SINGLE PHASE
AC100V~110V Brown
BLACK
MOTOR
{
Lead wire
WHITE
GRAY
MOTOR
SINGLE PHASE
AC200V~240V Yellow

RED
※ For the connection of something other than the
T.G
{
Lead wire RED T.G
box fan, refer to the electrical wiring diagram for
‘B’ FAN
the corresponding connection.
‘B’

202 SPG
▼ Panel ▼ Converting of multistage speed

SSBO3-SRSS
SLOW RUN
1.When multistage speed control is required, set each VR1,
HIGH VR1 Variable resistor for Slow Run period VR2 & VR3 and converting can be possible by using SWA, SWB,
10

CONTROL PACK
0

LOW

VOLT IPh. 220V and SWC. Keeping converting time of switching should be
FREQ. 60Hz SLOW STOP
MAX.
CURRENT 3A
HIGH VR2 Variable resistor for Slow Stop period similar to the operating time of relay operation.
10
0

LOW

MADE IN KOREA

▼ Speed control by using external direct current


VR1 1 VR2 1 VR3 1

2 2 2
When speed is controlled by external direct current instead of RUN
8 SW4 3 3 3
supplied variable resistor for external speed setting, connect the
9
wires of direct current with control pack as following diagram. STOP
SWA SWB SWC

(However, output of direct current has to be seperated and insulated with


alternative current input and avoid changing polarity.)

DIRECT CURRENT
1K
1/4W (0~6V 10mA) VR1,2,3 20㏀ 1/4W B Characteristic
8
SW1,2,3,4 DC 20V 10mA
9

2.In the packing of control pack there is one set of external


speed setting volume. When needed more, please purchase
(The connection of speed control by using external direct current.) SVR20KH of SPG.

▼ How to quicken operating speed ▼ Total system

SPEED CONTROLLER/CONTROL MOTORS


To quicken operating speed, as the set speed is decelerated, RUN/BRAKE SWITCH
there are more delays to start rotations when switch is turned
‘ON’. If this causes problems, please refer to following
diagram and connect VRT (Variable resistor for operating time
control) 9 8 7 6
RED
RED

4
Speed control
MOTOR
potentiometer
SW2 STOP
3
VR T

Speed control 10 11 1 2
2
RUN potentiometer
WHITE
BLACK

GRAY

20㏀ CONTROL PACK


8 3 1
VR

9 POWER
SOURCE

CONDENSER
ELECTRONIC POWER SWITCH
VRT 2㏀ 1/4W B Characteristic
SW2 DC 20V 10mA 1. Speed of motor can be controlled without steps by using
variable speed resistor for external speed setting.
Turn to (HIGH) for high speed, and (LOW) for low speed.
※ For instantaneous stop, operate both RUN/BRAKE switch and 2. There are operating current flowing on thick line.
RUN/STOP switch above. Use cable with 0.75㎟ for thick line and 0.5㎟ for thin line.
※ Place RUN/STOP switch to stop and control VRT until motor 3. For single-phase AC220V∼240V 50Hz motors, change gray
starts. wire to brown.

SPG 203