Professional Documents
Culture Documents
Variadores Velocidad Motores Ac Induccion PDF
Variadores Velocidad Motores Ac Induccion PDF
1. Characteristics
·Speed controller SR series are developed by the demands of
speed variation.
·It uses the IC circuit that our company independently developed
and is small, light weight and reliability.
·With acquisition of CE Mark certification, the product guarantees
higher reliability.
·The rotating speed of the motor may be adjusted by a speed
control variable resistor located at the front of the case and can
also operate long-range by an extra speed setter.
·Increase of instantaneous stop function by electromagnetic brake
·Miniaturized type with 11pin plug
The product acguired CE mark ..
(File NO. E9766429E01 Certificate Institute: TUV Rhinland)
SPECIFICATIONS
MODEL SR CE TYPE
SPEC SRA01CE SRA02CE SRB01CE SRB02CE SRC01CE SRC02CE SRD01CE SRD02CE SRX01CE SRX02CE
Rated Voltage AC110V 60Hz AC220V 60Hz AC100V 50/60Hz AC200V 50/60Hz AC220~240V 50Hz
Operation Voltage Range ±10%
INDUCTION 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W
APPLICABLE
MOTOR REVERSIBLE 6W 15W~40W 6W 15W~40W 6W 15W~40W 6W 15W~40W 6W 15W~40W
※1
OUTPUT
E·S 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W 6W 15W~90W
Speed control range 50Hz : 90~1400rpm 60Hz : 90~1700rpm
Speed variation 5%(standard)
Speed setting device Built in external speed setting device attachable
Braking Possible to stop for certain period by electric brake
※2 Braking period 0.5sec(standard)
Parallel operation Not suitable for parallel operation
Slow Run, Slow Stop none
Operation Temperature -10~50℃
Storage Temperature -20~60℃
Ambient humidity 85%Maximum(non condensing)
※1: Suitable motors are Socket Type Speed Control Motor of ours. (Use for 12V motor T.G)
※2: The electric brake does not have holding toque.
DIMENSIONS
▼ SR CE TYPE SPEED CONTROLLER 92
44 31
82.5 34 4 3.3
76
20
2
3.8
SRX01CE
HIGH
10
SPEED CONTROLLER
2- 5.2
0
LOW
VOLT 1Ph. 230V
SPEED
52MAX
FREQ. 50Hz
35.4
MAX.
25
1.2A
80
7
61
CURRENT
IP 2X
8
MADE IN KOREA
50 7
174 SPG
SCHEMATIC DIAGRAM
1-1 Uni Direction+Variable Speed 1-2 Uni Direction+Variable Speed+Brake
Note) 1. The motor rotating direction is CW when viewed from output shaft.
1. The motor rotating direction is CW when viewed from output shaft. When adjusting to CCW, change and connect white and
When adjusting to CCW, change and connect white and gray wire gray wire of motor.
2. When switched from Run to Stop, electric brake will function about
of motor.
0.5 sec. and motor will come to stop instantaneously.
2. The connection of a fan motor is applicable only if the output of
BRAKE BRAKE
the motor is greater than 60W and refer to page 175 for the
connection method. ◆ Example of operation SW1
RUN STOP RUN STOP
RED
(AC125WV ,AC250WV) ON
6 R 4.7Ω~6.8Ω MIN. 10W SW2
SW3 RUN STOP RUN STOP
11
MOTOR
PIN NO. CW CW
Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)
SPG 175
2-1 Reverse+Variable Speed 2-2 Reverse+Variable Speed+Brake
SW2
RUN of the motor is greater than 60W and refer to page 178 for the
7 SW4
CW
connection method.
BRAKE WHITE
10 Ro Co
CCW
GRAY SW1,3,4,5 AC125V
MIN. 5A
◆ Example of operation
RUN MOTOR or AC250V
SW5 R CW BRAKE BRAKE
5 10W BLACK
9 AC125V FORWARD STOP REVERSE STOP
BRAKE
Ro Co SW3 CCW
CAPACITOR F1 or AC250V
3A SW1 ON
PIN NO.
R 4.7Ω~6.8Ω MIN. 10W
Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)
176 SPG
3-1 External speed setting device 3-2 For prompt start(1)
F1 OFF ※ When starting of motor is slow while starting signal is input at Run
2
ON POWER
SOURCE
switch(SW1), use external volume VR at SW2 for Run/Stop.
1
SW2 STOP Speed control
SW1
Potentiometer
2
RUN 20㏀
4 3 1 F1 OFF
2
7 External speed setting device ON POWER
SOURCE
(20㏀ 1/4WB) 1
STOP SW1
SW2
7
11
External speed setting device to No. 2 pin of the socket PIN NO.
Note)
1. Set the volume to‘LOW’.
2. Shorten the connection cable as much as possible May cause
◆ Example of operation
faulty action. In such case use twist shield cable and connect it to
Min. 0.5sec
No.2 terminal. RUN STOP RUN
SW1
ON
F1 OFF
2 POWER
ON
SOURCE
1
SW1 Note)
1. Input time of SW1 should be about 0.5sec quicker than starting
VR1 1 VR2 1 VR3 1
signal of SW2.
2
2 2 2. Set the volume“LOW”and use external volume VR to control
Note)
1. Set the volume to‘LOW’.
2. If multi-stage speed control is needed, install VR1, VR2, and VR3
respectively and the speed can be changed by SWA, SWB,
and SWC. The open/close time of the switch is advised to
follow the open/close time of the relay contact point.
Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)
SPG 177
3-3 For prompt start(2) 3-4 Box fan motor connection method
▼ With Braking
INDUCTION MOTOR(6W~25W)
REVERSIBLE MOTOR (6W~25W) 2
F1 OFF
ON POWER
OFF SOURCE
1
2 POWER
SW1
ON
SOURCE PIN NO.
1
STOP SW1
SW6
Speed control
2
potentiometer
RUN RUN 20㏀ BLACK
SW7
{
3 3 1
MOTOR WHITE
BRAKE
GRAY MOTOR
6
RED
8
7
SW5
RUN
R
5 10W
BLACK
GRAY
T.G
{ RED
T.G
‘B’ FAN
BRAKE MOTOR
Ro Co WHITE ‘B’
◆ Example of operation ※ For the connection of something other than the box
Min. 0.5sec
BRAKE BRAKE fan, refer to the electrical wiring diagram for the
SW1
RUN STOP RUN STOP
corresponding connection.
ON
Note)
1. This wiring is for unidirection+Variable speed+braking of motors
25W or less. For motors 40W and over part of wiring is
different. Refer to the electrical wiring diagram for the corresponding
connection.
2. Input time of SW1 should be about 0.5sec quicker than SW6.
3. Set the volume“LOW”and use external volume VR to control speed.
4. When not in use for long period turn SW1 off.
Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)
178 SPG
4-1 Wire connection for electromagnetic brake motor 4-2 Wire connection for electromagnetic brake motor
When electric brake of controller is used at the same time When electric brake of controller is used at the same time
AC125V
STOP STOP
AC125V STOP REVERSE STOP
F1 3A
SW1 ON
F1 or AC250V 3A SW1 ON
or AC250V SW2
Min. 0.5sec
SW2
Min. 0.5sec
(AC125WV ,AC250WV)
SW4 CW CW (AC125WV ,AC250WV) SW4 CW CW
CCW CCW
Note 3. When Run/Stop, operate with SW2, SW4 while SW1 is on. Even with small signal it
1. Set the stop period to stop and convert to SW2 after rotation has stopped. can control the motor Turn SW1 off when not used for long period.
2. Input period for power switch SW1 should be about 0.5sec. quicker than the 4. Set the volume low and control the speed with external speed setting device VR.
signal of start operating of SW6, SW9. 5. The connection of a fan motor is applicable only if the output of the motor
is greater than 60W and refer to page 178 for the connection method.
Note)
The power switch should be off and check the PIN number when inserting a control pack into socket groove. (There is a possibility to be burned.)
SPG 179
SPEED CONTROLLER (SOCKET SS HIGH OUTPUT TYPE)
●SOCKET SS TYPE (HIGH OUTPUT)
Used for induction speed control motors of 6W∼90W, reversible speed
control motors of 6W~40W and electromagnetic brake speed control
motors of 6W~40W.
Built-in speed setting device on the case enables to control and set
the speed of motors.
Instantaneous stop function is possible by electric brake.
It is a compact plug-in type with 11pins so it is easy to set and use.
It has slow run and slow stop functions, so operating and braking
are not working rapidly, instead slowly.
There is time (period) setting device installed to control easily slow
run and slow stop function.
Parallel operation is possible.
※Parallel operation means that with one speed control volume,
▼ SPECIFICATIONS It can control plural speed controller at same time at same speed.
MODEL SS TYPE
Rated Voltage SINGLE-PHASE AC110V SINGLE-PHASE AC220V SINGLE-PHASE AC100V SINGLE-PHASE AC200V SINGLE-PHASE AC220V~240V
194 SPG
DIMENSIONS
SS TYPE (HIGH OUTPUT) SPEED CONTROLLER
92
▼ CONTROL PACK 82.5
44
76
SSBO3-SRSS
SLOW RUN 6
5 7
HIGH
10
CONTROL PACK 4 8
0
LOW
80
70
61
8
2 10
MAX. HIGH
CURRENT 3A
10
1 11
0
LOW
MADE IN KOREA
50
▼ 11PIN SOCKET
7.8
4
11-M3.5 L7
5 4
(118)
(81)
35.4
2 - 4.577HOLE
4
(33.5)
(50)
40MIN
13 20
M4 P0.7 L6
0.4 * *
Fixed screw
0.2
40
0.5
10
0
R3
12.5
3
40
24
24
0.2
40
0.2 9.5
3.2
Handle
Potentiometer
Panel( 40)
0.2
Insulator( 40)
Insulator
SPG 195
SCHEMATIC DIAGRAM(INDUCTION MOTOR)
1-1 Uni Direction+Variable Speed (6W-90W)
MOTOR
CW CW CW
MOTOR
CW CW CW CW
196 SPG
1-3 Uni Direction+Variable Speed+Brake (40W~90W)
OFF
10 POWER
ON
SOURCE
2 ▲For wiring of 220V-240V, 50Hz
SW2 STOP SW1 motor, change gray to brown.
2 Speed control
RUN potentiometer
20㏀
8 3 1
9 AC125V
SW1,4 MIN. 5A
7 or AC 250V
6
SW3 RUN
SW2,3 DC 20V 10mA
BLACK Ro=10~200Ω(MIN. 1/4W)
STOP
5 WHITE Co=0.1~0.2㎌
MOTOR Ro,Co
3 GRAY (AC125WV, AC250WV)
RUN R
SW4
4 STOP
10 10W
R: Braking
Ro Co external 10Ω, MIN. 10W
CAPACITOR RED T.G resistor
1
RED
11
PIN NO.
◆ Example of operation
BRAKE
BRAKE
SLOW RUN SLOW RUN
RUN STOP RUN STOP SLOW STOP STOP SLOW STOP STOP
SW1 ON
SW2
Note) RUN STOP RUN STOP RUN STOP
SW3
1. The motor’s rotating direction is CW when viewed from output shaft.
motor is greater than 60W and refer to page 202 for the
connection method.
● Run/Brake function
If SW3 and SW4 is turned to stop while SW2 is on RUN condition, the brake
will function for about 0.5 seconds and stop the motor instantaneously.
SPG 197
SCHEMATIC DIAGRAM(INDUCTION MOTOR)
2-1 Reverse+Variable Speed (6W~40W)
9 Ro Co
Ro,Co Co=0.1~0.2㎌
BLACK (AC125WV, AC250WV)
3 CW WHITE
SW3 MOTOR
4 GRAY
CCW
Ro Co
7
6
CAPACITOR
T.G
◆ Example of operation
SLOW RUN
RUN STOP RUN STOP SLOW STOP STOP
SW1 ON
RED
1 SW2 RUN STOP RUN STOP RUN STOP
RED
11 SW3 CW CCW CW
PIN NO. MOTOR CW CW
CCW
4 STOP CCW
CAPACITOR RUN STOP RUN STOP SLOW STOP STOP SLOW STOP STOP
Ro Co SW1 ON
198 SPG
2-3 Reverse+Variable Speed+Brake (40W)
OFF
10 SW1,4,5,6 AC125V MIN. 5A
ON POWER or AC 250V
SOURCE
2 SW2,3 DC 20V 10mA
STOP SW1
SW2 Ro=10~200Ω(MIN. 1/4W)
2
Speed control
RUN potentiometer Ro,Co Co=0.1~0.2㎌
8 3 1
20㏀
Ro Co
(AC125WV, AC250WV)
BLACK
9 R: Braking 10Ω, MIN. 10W
CW WHITE
7 SW5 MOTOR external
RUN GRAY resistor
SW3
6 CCW
Ro Co
STOP
5 CW
SW6 T.G
3 RUN R
SW4
4 STOP 10 10W CCW
CAPACITOR
◆ Example of operation
Ro Co
BRAKE BRAKE
SLOW RUN SLOW RUN
RED RUN STOP RUN STOP SLOW STOP STOP SLOW STOP STOP
1 SW1 ON
RED
11 SW2 RUN STOP RUN STOP RUN STOP
PIN NO. SW3
SW4 RUN BRAKE RUN BRAKE
SW5
SW6 CW CCW CW
CW
MOTOR CW CW CW
CCW
● Run/Brake function
If SW3 and SW4 is turned to stop while SW2 is on RUN condition, the brake
will function for about 0.5 seconds and stop the motor instantaneously.
SPG 199
SCHEMATIC DIAGRAM (E.S MOTOR)
3-1 Reverse+Variable Speed (6W~40W)
MOTOR CW CW CW
CCW
200 SPG
3-3 Uni Direction+Variable Speed+Brake (40W)
● Run/Brake function
If SW3 and SW4 is turned to stop while SW2 is on RUN condition, the brake
will function for about 0.5 seconds and stop the motor instantaneously.
SPG 201
APPLICATION OF SCHEMATIC DIAGRAM
▼ Parallel operation ▼ Usage(Parallel operation)
SS TYPE high output controller can control speed of multiple motors using Connect power supply line(Terminal No. ②,⑩)& control
one variable resistor as per following diagram at same speed. line (Terminal No. ⑧, ⑨) for same line like the side
wiring. In case of other motor and control pack, set
power line and control line for parallel operation.
6 7
10
CONTROL PACK
9 △! Warning
Connect to correct pin numbers for power line and
2 8 control line.
3 4 1 11 SVR
RED
RED
CAPACITOR
Although every motor runs at almost same speed,
there could be slight error due to difference of load
P MOTOR T C
O
and variation of products. To prevent this
O G
W N
T
phenomenon, prepare 5-10% of resistance and 1/4
E
R R
O
capacity of VR×(Variable resistance for speed
L L
setting)with SVR(Variable resistor for precise
I L
N I control) of terminal ⑧.
E N
6 7 E
10 9
CONTROL PACK
2 8
3 4 1 11
BLACK
WHITE
GRAY
RED
RED
CAPACITOR
3
OFF
10 POWER
ON
SOURCE
2
SW1
PIN NO.
VOLTAGE LEAD WIRE COLOR‘B’
SINGLE PHASE
AC100V~110V Brown
BLACK
MOTOR
{
Lead wire
WHITE
GRAY
MOTOR
SINGLE PHASE
AC200V~240V Yellow
RED
※ For the connection of something other than the
T.G
{
Lead wire RED T.G
box fan, refer to the electrical wiring diagram for
‘B’ FAN
the corresponding connection.
‘B’
202 SPG
▼ Panel ▼ Converting of multistage speed
SSBO3-SRSS
SLOW RUN
1.When multistage speed control is required, set each VR1,
HIGH VR1 Variable resistor for Slow Run period VR2 & VR3 and converting can be possible by using SWA, SWB,
10
CONTROL PACK
0
LOW
VOLT IPh. 220V and SWC. Keeping converting time of switching should be
FREQ. 60Hz SLOW STOP
MAX.
CURRENT 3A
HIGH VR2 Variable resistor for Slow Stop period similar to the operating time of relay operation.
10
0
LOW
MADE IN KOREA
2 2 2
When speed is controlled by external direct current instead of RUN
8 SW4 3 3 3
supplied variable resistor for external speed setting, connect the
9
wires of direct current with control pack as following diagram. STOP
SWA SWB SWC
DIRECT CURRENT
1K
1/4W (0~6V 10mA) VR1,2,3 20㏀ 1/4W B Characteristic
8
SW1,2,3,4 DC 20V 10mA
9
4
Speed control
MOTOR
potentiometer
SW2 STOP
3
VR T
Speed control 10 11 1 2
2
RUN potentiometer
WHITE
BLACK
GRAY
9 POWER
SOURCE
CONDENSER
ELECTRONIC POWER SWITCH
VRT 2㏀ 1/4W B Characteristic
SW2 DC 20V 10mA 1. Speed of motor can be controlled without steps by using
variable speed resistor for external speed setting.
Turn to (HIGH) for high speed, and (LOW) for low speed.
※ For instantaneous stop, operate both RUN/BRAKE switch and 2. There are operating current flowing on thick line.
RUN/STOP switch above. Use cable with 0.75㎟ for thick line and 0.5㎟ for thin line.
※ Place RUN/STOP switch to stop and control VRT until motor 3. For single-phase AC220V∼240V 50Hz motors, change gray
starts. wire to brown.
SPG 203