Microtech Testing & Research Laboratory: Condition of Sample, When Received: Satisfactory
Microtech Testing & Research Laboratory: Condition of Sample, When Received: Satisfactory
NC
ABOR Microtech Testing & Research Laboratory
MTRL (Contre for Tmspection, Testing & Certieation of mMateriats)
An ISO 9001:2015 Certifled Tosting Lab
WE FOCU
OcUs QUALIT
Near Double Lock Godown, Agasod Road, Bina,Distt. Sagar (M.P.) 470113
Contact No.: 09425679402, 09302872982, E-mall: mtrlbina@yahoo.com
TEST REPORT
S.NNo. Parameters Test Value Requirement as per Method of Test Ref. to IS Code
IS: 383-2016
Sieve Analysis % Passing Zone-1
IS-Sieve
10 mm 100 100
ii 4.75 mmn 100 90-100
2.36 mm 88 75-100
iv 1.18 mm 57 2386 (Part 1) RA 2016: 1963
55-90
600 micron 39 35 59
300 micron 15 8-30
vii 150 micron 09 0-10
Silt Content,% v/v 4.1
CPWD Vol. 1: 20009
Fineness Modulus 2.92
ng Resea,
1. Samples will be retained for 1 Month. Authotised Signatory
2. In case the sample is taken back, No further responsibility in case of
3. This report cannot be reproduced wholly or partly and can't be used as discrepancies
any SignALS
4. Result refer
oniy to the sample submitted for evidence any court of low or by
5. testing. any adverlising media.
Uncertainty is calculated at 95%% Confidence level for
approximates coverage factor k =2.