Comparison With Conventional Floor VS Fibermesh Floor

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

Comparision with Conventional floor

Sr Description Conventional Floor FIBERMESH FLOOR Significance

1 Reinforcment Laying 200-250 Kg per day with 2 One/Two person at the batching Saving in time and labour gives early
and tying Bar benders 2 Helpers ( 10 plant or at the mixer. Cutting bags handover and cost saving
hrs) for lesser diameter and dosing
else varies

2 Cover block 1 no of 50 mm thick Not required Saving in time and cost


Required per sqm
3 Inspection Inspection required after No inspection required Dramix Work can be done with minimum
reinforcement laying Fibers mix homogenously in supervision. Dramix fibers are
concrete due to gluing technlogy engineered to suit your local needs

4 Conecrete pouring Truck mixer or bag mixer Mixer can go to pouring site as Saving in lead time as distance
has to be loacted beyond there is no reinforcement between mixer and actual site is
the flooring area reduced

5 Screed vibrator Same Same


6 Troweling Same Same
7 VDC (Varies) Same Same
8 Tensile strength 415-500 N/mm ^2 Min 1050 N/MM^2 Higher tensile strength higher crack
control
9 Network 12mtrs per Mtr Square Min 360 Mtr per Square Meter More the netwrok better the
performance

10 Reinforcment At Particular Level Throughout the section Throughout reinforcment gives


excellent crack control and
redistribution of loads
11 Failure mode Brittle Ductile Better post carck behaviour better
post crack strength Ftcm

You might also like