Foundation Detail

Concrete Grade : M20


Steel Grade : Fe 500
Clear cover : 50 mm

GROUND FLOOR :
Overall Minimum
Factored Adopted Size Effective Depth Ast Provided Ast
Footing Footing Axial Load Axial Load Length Breadth Depth adopted required Diameter Spacing Number provide
name Type (KN) (KN) No (m) (m) (mm) (mm) (mm2) (mm) (mm) of bars d (mm2)
F1 Isolated 759 558 3 2.13 2.13 600 650 1661 12 140 15 1696.46
F2 Isolated 542 398 1 1.82 1.82 600 650 1419.6 12 140 13 1470.26
Eccentric
F3 solated 334 245 1 1.52 1.52 600 650 1185.6 12 130 11 1244.07

Overall Minimum
Factored Adopted Size Effective Depth Ast Provided Ast
Footing Footing Axial Load Axial Load Length Breadth Depth adopted required Diameter Spacing Number provide
name Type (KN) (KN) No (m) (m) (mm) (mm) (mm2) (mm) (mm) of bars d (mm2)
Combine
CF d footing A=391 A=287 1 2.53 2.53 500 550 1217 12 130 11 1244.07
B= 159 B=117