DQ for Purified Water System


NAME OF THE SYSTEM : PRETREATMENT & PURIFIED WATER GENERATION SYSTEM

TABLE OF CONTENTS

SR.
STAGE PAGE NO.
NO.

1 OBJECTIVE & SCOPE

2 ACCEPTANCE CRITERIA

3 RESPONSIBILITY

4 SYSTEM DESCRIPTION (SYSTEM AND SUB-SYSTEM)

5 BASIS OF DESIGN AND ASSUMPTION

6 TECHNICAL SPECIFICATIONS

7 DRAWINGS REQUIRED

8 SUPPORTING UTILITIES

9 PRE-QUALIFICATION CHECKLIST

10 LIST OF DOCUMENTS REQUIRED

11 DESIGN QUALIFICATION REPORT APPROVAL


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 1/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

12 ABBREVIATIONS

1. OBJECTIVE AND SCOPE

OBJECTIVE

1. To prepare detailed specification for all major components of Equipment / instrument to ensure that the User
Requirement Specification and functional requirement specification are achieved.

2. To design the equipment / instrument in conjunction with the design data in order to provide basis for
vendor, manufacturer & / or the design engineer for designing the system when the project begins.

SCOPE

Application to any equipment, system, facility, process & software programs.

1. When subjected for new installation

2. When the existing system is replaced with the new system.

3. When the existing system is subjected for up-gradation or modification.

All URS and FRS shall be defined by the user department in consultation with the engineering department,
which should be finalized and mutually discussed with the system supplier, vendor & or manufacturer.

The design qualification is essential part of the qualification mechanism and will serve as a basic document
for the Validation Activity.

2. ACCEPTANCE CRITERIA

2. A) PURIFIED WATER GENERATION SYSTEM

A.1 Equipment / Utility system shall confirm to specifications which are as per the user requirements/as per
USP 39.

A.2 The Equipment / Utility / system shall confirm to the predetermined requirements and a certificate is
issued by the projects / Engineering Department.

DESIGN BASIS

RAW WATER ANALYSIS Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 2/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

One year warranty



LEFOO RO booster pump
Factory 45,000 square metre, 35 engineers. Strong ODM & OEM. Huge
production capacity.
en.lefoo.com.cn

OPEN

Sr. No. Water Parameters Actual Parameters Design Consideration

1 Colour < 5 CTU < 5 CTU

2 pH 7.5 6.5 – 8.5

3 Conductivity (us/cm) 900 1200

4 Turbidity 1.8 Less than 5

5 SDI Not check < 3 assumed

6 Total Dissolved Solids 750 ppm 900 ppm

7 Total Alkalinity 120 ppm 120 ppm

8 Total Hardness 300 ppm 350 ppm

9 Calcium as CaCO3 100 ppm 125 ppm

10 Magnesium as CaCO3 200 ppm 225 ppm

11 Sodium as Na 36.11 ppm 50 ppm

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 3/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

12 Potassium as K 0.975ppm 5 ppm

13 Sulphate as SO4 43.68 ppm 50 ppm 

14 Nitrates as NO3 2.3 ppm 10 ppm

15 Chlorides as Cl 92.3 ppm 100 ppm

16 Flouride 0.7 ppm 1 ppm

17 Colloidal Silica 5.6 ppm 10 ppm

18 Reactive Silica 5.6 ppm 10 ppm

19 TOC 1000 ppb 1000 ppb

20 Total Plate Count 79 CFU/ml 1000 CFU/ml

(Note. 1. Feed Water is free from pathogens like E- Coli, Pseudonymous, Salmonella)

2. B) PRETREATMENT & PURIFIED WATER GENERATION SYSTEM

FOR PRESSURE QUARTZ FILTER

END USE : SOFTENER

QUANTITY OF WATER : 7 m3/hr

TYPE OF OPERATION : MANUAL OPERATION

FOR SOFTENER

END USE : PURIFIED WATER GENERATION SYSTEM


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 4/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

QUANTITY : 3.8 m3/hr

OBR : 76 m3

NO OF HRS : 20 hrs

TYPE OF OPERATION : MANUAL OPERATION

FIRST PASS RO SYSTEM (Hot Water Sanitizable)

FEED FLOWRATE : 3800 LPH

REJECT FLOWRATE : 1100 LPH

PERMEATE FLOWRATE : 2700 LPH

OVER ALL RECOVERY : 70 %

TYPE OF OPERATION : FULLY AUTO & MANUAL OPERATION

SECOND PASS RO SYSTEM (Hot Water Sanitizable)

FEED FLOWRATE : 2700 LPH

REJECT RECYCLE FLOWRATE : 500 LPH

PERMEATE FLOWRATE : 2200 LPH

OVER ALL RECOVERY : 80 %

TYPE OF OPERATION : FULLY AUTO & MANUAL OPERATION

FOR EDI SYSTEM


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 5/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

FEED FLOWRATE : 2200 LPH

PERMEATE FLOWRATE : 2000 LPH 

REJECT FLOWRATE : 200 LPH

TYPE OF OPERATION : FULLY AUTO & MANUAL OPERATION

OVERALL RECOVERY : 90 %

TREATED WATER QUALITY

STAGE WISE TREATED WATER QUALITY AFETR RO:

(On basis of maximum feed water limiting condition)

Sr. Outlet of Multi Outlet of Outlet of RO Outlet of RO


Water Parameter
No. Grade Filter Softener Pass I Pass II

1. Ph 6 to 8.5 6 to 8.5 5–6 5–6

TSS < 5 ppm < 5 ppm Nil Nil

2. TDS / Conductivity 1920 us/cm 1920 us/cm 200 us/cm 25 us/cm

Total Hardness ( in
3. 350 ppm Less than 5 ppm Nil Nil
ppm)

4. SDI <3 3.0 max Nil Nil

5. TOC 1000 ppb 1000 ppb 500 ppb 200 ppb

6. TVC 1000 CFU/ml 1000 CFU/ml 100 CFU/ml 50 CFU/ml

TREATED WATER QUALITY AFTER UF : ( as per ‘Design Limits’)

(PURIFIED WATER AS PER USP 39 std.)

Sr. Action Design


Water Parameters USP 39 Alert Limit
No. Limit Limit

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 6/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

1. Conductivity 1.25 µs/cm 1.0 µs/cm 0.8 µs/cm 0.7 µs/cm

2. TOC in PPB 500 ppb 300 ppb 200 ppb 100 ppb 

TVC / TBC
3. 100 CFU/ml 90 CFU/ml 70 CFU/ml 40 CFU/ml
Microbial Count

Note: With the change in the incoming water parameters, the treated water quantity & quality may get
affected at different stages of the plant.

3. RESPONSIBILTY

User Dept : For providing user requirement (Technical and cGMP)

Head-Operations : To review the specification from installation and Maintenance aspects.

Head-Quality : To review the specification from GMP Aspects

Vendor : To review and agree upon the requirements.

4. SYSTEM DESCRIPTION (SYSTEM AND SUB-SYSTEM)

The Fully Automated PLC based Purified Water Generation system generate 2 m3/hr. of Purified water as Per

USP 39 Standards.

SCHEME:

PRETREATMENT & PURIFIED WATER GENERATION SYSTEM:

PRE TREATMENT: (3800 LPH)

Pre Sodium Hypo Chlorite Dosing System

Raw Water Pumps

Multi Grade Filter

Softener Unit

FIRST PASS REVERSE OSMOSIS (HOT WATER SANITIZABLE) SYSTEM:

SMBS Dosing System


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 7/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Antiscalent Dosing System

pH Correction System

5 – Micron Cartridge Filter

ORP Analyzer and pH sensor along with auto Dumping Valve

RO High Pressure Pump

Reverse Osmosis Membranes along with High Pressure Housing

Conductivity Meter with Alarm

SECOND PASS REVERSE OSMOSIS (HOT WATER SANITIZABLE) SYSTEM:

RO High Pressure Pump

Reverse Osmosis Membranes along with High Pressure Housing

Conductivity meter with Alarm

POST TREATMENT:

Hot Water Sanitizable Electro – Deionization Unit

Conductivity meter with Alarm

SYSTEM DESCRIPTION:

Raw water before Raw Water Tank is dosed with Sodium Hypochlorite 1 – 2 ppm. Raw water feed pump will

feed raw water from the raw water storage tank to Multi Grade Filter @ 7000 LPH.

Multi Grade Filter is a vertical down flow vessel containing pure graded silex quartz as a filtering media.

The vessel is fabricated in FRP. The water generated at the outlet of Multi Grade Filter will have suspended
solids less than 5 ppm. Multi Grade Filter is provided with Manual Backwash. We have provided manual ball

valves of for change over from normal operation to Backwash operation.

(Note that the inlet suspended solid load should not be more than 50 ppm).

The water from Multi Grade Filter is passed through Softener. Hardness after softener is less than 5 ppm.
Soft Water after Softener unit is fed to Purified Water Generation System.

Sodium Metabisulphite (Na2S2O5) is then dosed in the chlorinated water to neutralize the free chlorine

(excess chlorine) present in the filtered water.


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 8/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Antiscalent Dosing System is then dosed in the soft water to avoid scale formation on the RO Membranes.

pH Correction Dosing System is provided to adjust the feed pH of RO feed water as 6.5 – 8.5. The treated
water is then passed through 5 micron Cartridge Filter to trap the suspended solids. This will avoid

chocking of RO membranes due to suspended solids.

ORP Analyzer is provided so as to check the absence/presence of chlorine in the feed water to the RO
System. If free chlorine is sensed in the feed water it will give an indication on the panel & open the

dumping valve and dump the high ORP water for 300 secs. & Even if the ORP value is not below the

set point it will trip the system.

This soft water is then fed to the Reverse Osmosis First pass System by means of a High Pressure Vertical

multistage Pump with SS 304 wettable parts of M/s. Grundfos, Denmark. The First pass Reverse Osmosis

System will generate 2700 liters/hr water with an overall recovery of 70 %. The generated water will have
total dissolved solids less than 150 ppm. The semi-permeable reverse osmosis membrane has molecular

weight cut off less than 150 MWCO. The Reveres Osmosis membrane acts as positive barrier to remove
dissolved solids, organic compounds & bacteria.

The Reverse Osmosis System consists of thin film composite type Reverse Osmosis membrane of DOW.
The material of construction of the RO membrane is Polyamide. The RO membrane is housed in the High

Pressure SS 316L Wettable Parts Housing having TC end connection.

The outlet water of RO pass one is feed to RO pass two system. The Second pass Reverse Osmosis System
will generate 2200 liters/hr of water with an overall recovery of 80%. The generated water will have total

dissolved solids less than 15-20 ppm.

The Reverse Osmosis System consists of thin film composite type Reverse Osmosis membrane of DOW.

The material of construction of the RO membrane is Polyamide. The RO membrane is housed in the High
Pressure SS 316L Wettable Parts Housing having TC end connection.

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 9/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

The Permeate water from RO system will be fed to the Electro Deionization Unit (EDI) having designed

capacity of 2000 LPH. The EDI system has a recovery of 90%.



The water generated from the outlet of EDI will be as per USP 39 Standards for Purified Water.

5. BASIS OF DESIGN AND ASSUMPTION

FEED WATER SAMPLE:

The system design is based on the feed water analysis provided by the customer as per Annexure -A.

PRODUCT WATER QUALITY:

STAGE WISE TREATED WATER PARAMETER:

(On basis of maximum feed water limiting condition)

Sr. Outlet of Multi Outlet of Outlet of RO Outlet of RO


Water Parameter
No. Grade Filter Softener Pass I Pass II

1. Ph 6 to 8.5 6 to 8.5 5–6 5–6

TSS < 5 ppm < 5 ppm Nil Nil

2. TDS / Conductivity 1920 us/cm 1920 us/cm 200 us/cm 25 us/cm

Total Hardness ( in
3. 350 ppm Less than 5 ppm Nil Nil
ppm)

4. SDI <3 3.0 max Nil Nil

5. TOC 1000 ppb 1000 ppb 500 ppb 200 ppb

6. TVC 1000 CFU/ml 1000 CFU/ml 100 CFU/ml 50 CFU/ml

TREATED WATER QUALITY AFTER UF: (as per ‘Design Limits’) (PURIFIED WATER AS PER USP 39

std.)

Sr. Action Design


Water Parameters USP 34 Alert Limit
No. Limit Limit

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 10/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

1. Conductivity 1.25 µs/cm 1.0 µs/cm 0.8 µs/cm 0.7 µs/cm

2. TOC in PPB 500 ppb 300 ppb 200 ppb 100 ppb 

TVC / TBC

3. 100 CFU/ml 90 CFU/ml 70 CFU/ml 40 CFU/ml


Microbial Count

Note: With the change in the incoming water parameters, the treated water quantity & quality may get

affected at different stages of the plant.

5.3 FACILITY OPERATION:

The plant operation will be for 20 hrs/day,6 days/week,48 weeks/year

ANNEXURE – A

Sr. No. Water Parameters Actual Parameters Design Consideration

1 Colour < 5 CTU < 5 CTU

2 pH 7.5 6.5 – 8.5

3 SDI 900 1200

4 Total Dissolved Solids 1.8 Less than 5

5 Total Alkalinity Not check < 3 assumed

6 Total Suspended Solids 750 ppm 900 ppm

7 Total Hardness 120 ppm 120 ppm

8 Calcium as CaCO3 300 ppm 350 ppm

9 Magnesium as CaCO3 100 ppm 125 ppm

10 Sulphate as SO4 200 ppm 225 ppm

11 Nitrates as NO3 36.11 ppm 50 ppm


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 11/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

12 Chlorides as Cl 0.975ppm 5 ppm

13 Silica as SiO2 43.68 ppm 50 ppm 

14 Colloidal Silica 2.3 ppm 10 ppm

15 Reactive Silica 92.3 ppm 100 ppm

16 Total Chloride as CaCO3 0.7 ppm 1 ppm

17 Sulphate as CaCO3 5.6 ppm 10 ppm

18 TOC 5.6 ppm 10 ppm

19 TVC 1000 ppb 1000 ppb

(Note. 1. Feed Water is free from pathogens like E- Coli, Pseudonymous, Salmonella)

6. TECHNICAL SPECIFICATIONS

6.A MAJOR EQUIPMENTS OF PRETREATMENT & PURIFIED WATER GENERATION SYSTEM:

6.A.1 PRE SODIUM HYPOCHLORITE DOSING SYSTEM

TAG NO: NaOCl (DT-01 / DP-01)

EQUIPMENT NAME: Pre Sodium Hypo Chlorite Dosing system

EQUIPMENT LOCATION: After Bore Well Pump

FUNCTION: For Bacterial Disinfection in raw water. These will inhibit the bacterial growth. Sodium Hypo

chlorite dosed up to 2 ppm for disinfection.

TECHNICAL SPECIFICATION:

Quantity : One

Type : Positive Displacement Pump

Pump Capacity : 0.4 to 4 LPH

Max. Working Pressure : 5.5 kg/cm2

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 12/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

MOC of Dosing Tank : HDPE

Dosing Tank : 50 Liters Provided 

Low Level Switch : Provided

Make : Milton Roy

Model : UC 11

DOSING CALCULATION:

Dosage required : 2 ppm

Feed Flow rate : 7 m3/hr

Conc. of Solution : 1%

Dosing Pump flow rate : 1.4 LPH

Amount of dosing solution = 1.4 x 24 = 33.6 Ltrs.

6.A.2 RAW WATER PUMPS (1W + 1SB):

TAG NO: RWP-01 / 02

EQUIPMENT NAME: Raw Water Pumps

EQUIPMENT LOCATION: After Raw Water Storage Tank

FUNCTION: For pumping of Raw water to Pretreatment @ 7 m3/hr.

TECHNICAL SPECIFICATION:

Quantity : Two (1W + 1SB)

Type : Horizontal Multistage pump

Flow rate : 7 m3/hr (7000 liter/hr)

Head : 35 mWC
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 13/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Material of Construction : SS 304

Make : Nanfang 

6.A.3 MULTI GRADE FILTER:

TAG NO: MGF-01

EQUIPMENT NAME: Multi Grade Filter

EQUIPMENT LOCATION: After Sodium Hypo-chlorite Dosing System, Piping and Raw Water Tank.

FUNCTION: It filters the suspended solids in the Raw water up to 5 ppm with the help of Multi Grade Filter
in the vessel, the inlet suspended solids should be less than 50 ppm.

TECHNICAL SPECIFICATION:

Quantity : One

Flow rate : 7 m3/hr

Max. Working Pressure : 3.5 kg/cm2

Max. Pressure Drop : 0.5 kg/cm2

Diameter : 600 mm

Height : 1800 mm

Specific Velocity of Filtration : 25 m/hr.

Back Wash Time Required : 10-15 min.

Filter media : Pure Graded Silex Quartz of 1.5 to

2 mm Particle size.

Valve Type : Ball valve

MOC of Pressure Vessel : Fiber Reinforced Plastic (FRP)

Make of Pressure Vessel : M/s. Wave Cyber, USA / Pentair


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 14/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Frontal Pipe Size : 38.1 mm

Pressure gauge : 100 mm Dial ( Inlet /Outlet ) 

MOC Piping : UPVC

Make of Piping : FIP

MOC of Valves : UPVC

Make of Valves : FIP

Inlet, Outlet, Drain Connection : 1.5” BSPF union ends

Operation:

1. Normal Operation

2. Back Wash Operation

3. Rinse Operation

1. Normal Operation:

Since MGF is a Vertical Down Flow Vessel the Suspended Solids are removed by passing through Filtering

Media which is been 60% filled. For normal operation position of Ball valves which are mounted on MGF
should be (In Open Position: BV-05 & BV-06)

(In Close Position: BV-07, BV-08 & BV-09)

2. Back Wash Operation:

WHEN & WHY BACKWASH

Back Wash is used to remove the Suspended Matter which is entrapped in the filter Media Top Layer

during Normal Operation. Back Wash is done after 20 hr OR if the differential pressure across the filter is

more than 0.5 kg/cm2.

For changing from normal operation to backwash operation, the position of the Ball Valves should be (In

Open Position: BV-07 & BV-08)

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 15/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

(In Close Position: BV-05, BV-06 & BV-09)

3. Rinse Operation: 

WHEN & WHY BACKWASH

Rinse Operation is done after Back Wash. Rinse is done to remove the Suspended Solid which is

entrapped in the Filter Media during Backwash Operation.

For changing from Back Wash operation to Rinse operation, the position of the Ball Valves should be (In

Open Position: BV-05 & BV-09)

(In Close Position: BV-06, BV-07 & BV-08)

6.A.4 SOFTENER:

TAG NO: SF-01

EQUIPMENT NAME: Softener Unit-01

EQUIPMENT LOCATION: After Multi Grade Filter

FUNCTION: It will replace the hardness causing Ca & Mg ions with Na ions. This will soften the raw water

and will avoid scale formation. Treated Water at the outlet of softener-II will have hardness less than 5 ppm.
Flow totalizer will be provided at the outlet of softener unit to indicate the amount of soft water generated

and give indication after pre define quantity of soft water is generated.

TECHNICAL SPECIFICATION:

Quantity : One

Type : Vertical Up Flow

Flow rate : 3.8 m3/hr

Max. Working Pressure : 4 kg/cm2

Max. Pressure Drop : 0.5 kg/cm2

Diameter : 600 mm

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 16/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Height on straight : 1800 mm

Regeneration Time Required : 20-30 min. 

Fast Rinse : 5-10 Minutes

Resin Quantity : 450 ltrs.

Make of Resin : M/s. Lenxess

Model of Resin : C 249

Regenerator (NaCl) : 72 Kgs.

Reg. Tank Capacity : 300 lts.

MOC of Reg .tank : HDPE

MOC of Softener : Fiber Reinforced Plastic (FRP)

Make of Vessel : M/s. Wave Cyber, USA / Pentair

Frontal Pipe Size : 38.1 mm

Valve : Ball valve

Pressure gauge : 100 mm Dial ( Inlet /Outlet )

Frontal Piping : UPVC

Make of Piping : FIP

Make of Valves : FIP

Operation:

1. Normal Operation

2. Regeneration Operation

3. Slow Rinse Operation

4. Fast Rinse Operation

1. Normal Operation:
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 17/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Since Softener is a Vertical UP Flow Vessel the Hardness causing Ions are removed by passing through

Resin Media (Cation and Anion) which is been 92% filled of the Total Volume. For normal operation the

position of the Ball valves should be:

(In Open position: BV-10, BV-11) & (In Close position: BV-12/13/14/15)

After 12 hrs of operation of the softening plant OR after 72 m3 of OBR the softener should go under

regeneration mode or the hardness does not get maintain within its limit..

2. Regeneration Operation:

WHEN & WHY REGENERATION

Regeneration is used to recharge the Resin to regain its absorbing properties of hardness. Regeneration is

done if the Hardness at the Outlet of Softener Unit is above 5 ppm OR after 72 m3 OBR / 12 hrs of

Operation of plant whichever is earlier. Flow Totalizer will be provided at the outlet of each softener unit to

indicate the amount of soft water generated and give indication of Regeneration after pre define quantity of

soft water generation.

For changing from normal operation to regeneration mode, the valve position should be

(In Open position: BV-12/13/14) & (In Close position: BV-10/11/15)

Allow the softener to backwash completely.

Allow the brine solution to get completely charged in the softener.

3. Slow Rinse Operation:

Slow Rinse is used to get properly mix up with Salts & Resins.

(In Open position: BV-12/14) & (In Close position: BV-10/11/13/15)

4 Fast Rinse Operation:

Fast Rinse is used to remove excess Salts from the resins.

(In Open position: BV-10/15) & (In Close position: BV-11/12/13/14)

6.A.5 SODIUM META BISULPHITE DOSING SYSTEM:


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 18/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

TAG NO: SMBS (DT-02 / DP-02)

EQUIPMENT NAME: Sodium Meta Bisulphate Dosing system 

EQUIPMENT LOCATION: After Softener Unit

FUNCTION: 1 ppm of chlorine needs 2 ppm SMBS dosing. We have considered 2 ppm of chlorine so we
have assumed 4 ppm of SMBS dosing. 6 ppm SMBS is dosed in soft water to neutralize the free chlorine in

soft water. (Note: ORP analyzer is provide with dumping valve to check & dump the high chlorinated water)

TECHNICAL SPECIFICATION:

Quantity : One

Type : Positive Displacement Pump

Pump Capacity : 0.4 to 4 LPH

Max. Working Pressure : 5.5 kg/cm2

MOC of Dosing Tank : SS 304

Dosing Tank : 25 Liters Provided

Low Level Switch : Provided

Make : Milton Roy

Model : UC 11

DOSING CALCULATION:

Dosage required : 4 ppm

Feed Flow rate : 3.8 m3/hr

Conc. of Solution : 1%

Dosing Pump flow rate: 1.52 LPH

If we consider 3 shifts of 8 hrs. = 8 x 3 = 24 hrs.

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 19/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Amount of dosing solution = 1.52 x 24 = 36.48 Ltrs.


6.A.6 ANTISCALENT DOSING SYSTEM:

TAG NO: ADS (DT-03 / DP-03)

EQUIPMENT NAME: Anti Scalent Dosing System

EQUIPMENT LOCATION: After SMBS Dosing System

FUNCTION: ADS (5 ppm) is dosed in soft water to avoid scaling in RO membrane.

TECHNICAL SPECIFICATION:

Quantity : One

Type : Positive Displacement Pump

Pump Capacity : 0.4 to 4 LPH

Max. Working Pressure : 5.5 kg/cm2

MOC of Dosing Tank : SS 304

Dosing Tank : 25 Liters Provided

Low Level Switch : Provided

Make : Milton Roy

Model : UC 11

DOSING CALCULATION:

Dosage required : 5 ppm

Feed Flow rate : 3.8 m3/hr

Conc. of Solution : 2%

Dosing Pump flow rate: 0.95 LPH


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 20/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

If we consider 3 shifts of 8 hrs. = 8 x 3 = 24 hrs.

Amount of dosing solution = 0.95 x 24 = 22.8 Ltrs. 

6.A.7 pH CORRECTION DOSING SYSTEM:

TAG NO: pHC (DT-04 / DP-04)

EQUIPMENT NAME: pH Correction Dosing System

EQUIPMENT LOCATION: After Anti-scalent dosing system

FUNCTION: To boost up the pH of RO feed water so as to convert the dissolved CO2 into alkalinity and

which can be rejected in RO Pass I.

TECHNICAL SPECIFICATION:

Quantity : One

Type : Positive Displacement Pump

Pump Capacity : 0.4 to 4 LPH

Max. Working Pressure : 5.5 kg/cm2

MOC of Dosing Tank : SS 304

Dosing Tank : 25 Liters Provided

Low Level Switch : Provided

Make : Milton Roy

Model : UC 11

pH Correction Chemical : NaOH or Na2CO3

6.A.8 5-MICRON CARTRIDGE FILTER:

TAG NO: CF – 01
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 21/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

EQUIPMENT NAME: 5 – Micron Cartridge Filter

EQUIPMENT LOCATION: After SMBS / ADS / pHC Dosing Systems 

FUNCTION: It filter all the suspended solids in water greater than 5 – micron thus avoid chocking in RO
membrane.

TECHNICAL SPECIFICATION:

No. of Unit : One

Type of Cartridge : Spun Bounded Type

Rating : 5 micron

Flow rate : 3800 LPH

No. of Cartridge : 2 nos. 20” long

MOC of Cartridge Housing : SS 304

MOC of Cartridge : PP ( Polypropylene)

Make of Cartridge : Kumar/Pratham

Make of Housing : HydroPure Systems

Surface Finish of Housing : Internally – < 0.4 Ra

Externally – mirror up to 180 grit

Type of Filter : Double open end filter

6.A.9 REVERSE OSMOSIS HIGH PRESSURE PUMP-I:

TAG NO: ROHP – I

EQUIPMENT NAME: Reverse Osmosis High Pressure Pump- I

EQUIPMENT LOCATION: After 5-micron Cartridge Filter


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 22/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

FUNCTION: For pumping of water to RO pass-I system. @ 3.8 m3/hr

TECHNICAL SPECIFICATION: 

Quantity : One

Type : Vertical Multistage Pump

Flow rate : 3.8 m3/hr (3800 liter/hr)

Pressure : 12 kg / cm2

Material of Construction : SS 304 Wettable parts

Voltage Requirement : 415 Volts

Make : Grundfos

6.A.10 REVERSE OSMOSIS MEMBRANES:

EQUIPMENT NAME: Reverse Osmosis Membranes

EQUIPMENT LOCATION: Within the RO System

FUNCTION: RO membranes reduce the TDS & microbial load in the water. The semi-permeable reverse

osmosis membrane has molecular weight cut off less than 150 MWCO. The Reveres Osmosis membrane

acts as positive barrier to remove dissolved solids, organic compounds & bacteria. Membranes consist of
thin film composite type. It will bring down the conductivity less than 200 μs/cm.

TECHNICAL SPECIFICATION:

No. of Membrane : 4 Nos.

Size of Membrane : 8” Dia. & 40” Long

Type of Membrane : Thin Film Composite

Type of Sanitization : Hot Water Sanitizable

Material of Construction : Polyamide

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 23/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Make of Membrane : DOW.

Model : HSRO-390FF 

Operating Temperature : 450 C

Recovery : 70 %

Feed Water Flow Rate : 3800 m3/hr

Permeate Flow Rate : 2700 m3/hr

Reject Water Flow Rate : 1100 m3/hr

Sanitization Temp. : 850 C

6.A.11 REVERSE OSMOSIS HOUSING:

TAG NO: RO PASS – I

EQUIPMENT NAME: Reverse Osmosis Housing

EQUIPMENT LOCATION: After RO High Pressure – I

FUNCTION: RO membranes are housed in the housing.

TECHNICAL SPECIFICATION:

No. of Housing : One

No. of Membranes in RO Housing : 4 Nos.

Make of Housing : HydroPure Systems

Material of Construction : SS 304

Diameter : 204 mm

Length : 4060 mm

Thickness : 2.5 mm

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 24/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Surface Finish of RO Housing : Internally – < 0.4 Ra

Externally – mirror up to 180 grit 

Maximum Flow rate for housing : 4000 LPH

Permeate flow rate from RO Pass I is 2.7 m3/hr.

6.A.12 REVERSE OSMOSIS HIGH PRESSURE PUMP-II:

TAG NO: ROHP – II

EQUIPMENT NAME: RO High Pressure Pump – II

EQUIPMENT LOCATION: After RO pass – I

FUNCTION: For pumping of water to RO pass – II system.

TECHNICAL SPECIFICATION:

Quantity : One

Type : Vertical Multistage Pump

Flow rate : 2.7 m3/hr (2700 LPH)

Pressure : 9 kg/cm2

Material of Construction : SS 316 wettable parts

Voltage Requirement : 415 volts

Make : Grundfos

6.A.13 REVERSE OSMOSIS MEMBRANES:

EQUIPMENT NAME: Reverse Osmosis Membranes

EQUIPMENT LOCATION: Within the RO Housing

FUNCTION: RO membranes reduce the TDS & microbial load in the water. The semi-permeable reverse
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 25/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

osmosis membrane has molecular weight cut off less than 150 MWCO. The Reveres Osmosis membrane
acts as positive barrier to remove dissolved solids, organic compounds & bacteria. Membranes consist of

thin film composite type. This will bring down the conductivity less than 25 μs/cm.

TECHNICAL SPECIFICATION:

No. of Membrane : 2 Nos.

Size of Membrane : 8” Dia. & 40” Long

Type of Membrane : Thin Film Composite

Type of sanitization : Hot water

Temperature of sanitization : 850 C

Material of Construction : Polyamide

Make of Membrane : DOW.

Model : HSRO-390FF

Operating Temperature : 450 C

Recovery : 80-85 %

Feed Water Flow Rate : 2.7 m3/hr

Permeate Flow Rate : 2.2 m3/hr

6.A.14 REVERSE OSMOSIS HOUSING:

TAG NO: PWG-RO PASS II

EQUIPMENT NAME: Reverse Osmosis Housing

EQUIPMENT LOCATION: After RO High Pressure – II

FUNCTION: RO membranes are housed in the housing.

TECHNICAL SPECIFICATION:
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 26/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

No. of Housing : One

Make of Housing : HydroPure Systems 

Material of Construction : SS 316L

Diameter : 204 mm

Length : 2040 mm

Thickness : 2.5 mm

Surface Finish of RO Housing : Internally – < 0.4 Ra

Externally – mirror up to 180 grit

Max Feed Flow rate : 3000 LPH

6.A.15 ELECTRO DEIONIZATION UNIT:

TAG NO: EDI – 01

EQUIPMENT NAME: Electro De-Ionization System

EQUIPMENT LOCATION: After RO pass II

FUNCTION: EDI bring down the conductivity of RO treated water. The water generated from the outlet of

EDI will be as per USP 34.

TECHNICAL SPECIFICATION:

No. of Unit : One

Type : Hot Water Sanitizable

Model No. : IP – LXM 24 – HI-3

Minimum Flow rate : 1400 ltrs/hr

Maximum Flow rate : 4200 Ltrs/hr

Normal Flow rate : 2800 ltrs/hr


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 27/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

End Connection : 1” TC

Operating Voltage DC : 150 – 250 V DC 

Maximum Voltage : 300 V

Operating Current : 1 – 3 Amps

Maximum Current : 5 – 6 Amps.

Concentrate Flow rate (Reject) : 250 LPH

Pressure Drop across concentrate : 0.5 kg/cm2

Max. Working Pressure : 2.5 kg/cm2

Make of EDI : M/s. Ion Pure EDI, USA

Material of Construction of different parts:

Dilute Spacer : Polysulfone

Concentrate Spacer : Polysulfone

End Block : Polypropylene

Resin compartment O-rings : FDA-grade silicon

Anion exchange resin 1 : Styrene / DVB, strong base, type I

Anion exchange resin 2 : Styrene / DVB, strong base, type II

Cation exchange resin : Styrene / DVB, strong acid

Anion exchange membrane : Heterogeneous PE/AER

Cation exchange membrane : Heterogeneous PE/CER

Anode : Platinized Titanium

Cathode : SS 316

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 28/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

6.A.16 CIP TANK

TAG NO: CIP-ST 

EQUIPMENT NAME: CIP Tank

EQUIPMENT LOCATION: Before CIP feed pump

FUNCTION: For Sanitization.

TECHNICAL SPECIFICATION:

Quantity : One

Make : Hydro pure

Type : Plain Tank

Working Capacity : 200 Liters

Gross Capacity : 220 Liters

Tank Dia ID : 600 mm

Shell Height : 750 mm

Design Pressure & Tempe. : 3.5 Kg/cm2 & 120oC

Design Code : cGMP

Top & Bottom : Torispherical Dished end

M.O.C. of Shell : SS 316 L

Nozzles : Triclover end

Surface Finish : Internally electro polished to <0.4 micron Ra.

Externally buffed to mirror finish

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 29/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

6.A.17 CIP FEED PUMP:

TAG NO: CIP – CIPFP 

EQUIPMENT NAME: CIP Feed Pump

EQUIPMENT LOCATION: Trolley Mounted

FUNCTION: Pumps Purified water to RO system @ 2.5 m3/hr

TECHNICAL SPECIFICATION:

Quantity : One

Type : Horizontal Multistage Pump

Flow rate : 2.5 m3/hr (2500 liter/hr)

Pressure : 2.9 kg / cm2

Material of Construction : SS 316 wettable parts

Voltage Requirement : 3 Phase, 415 volts

Make : Grundfos

6.B INSTRUMENTATION & OTHER ITEMS

6.B.1.1 PRESSURE GUAGES:

TAG NO: PG-01 / 02 / 03

INSTRUMENT NAME: Pressure Gauges

LOCATION: 1) Inlet of Multi Grade Filter

2) Outlet of Multi Grade Filter

3) Outlet of Softener

FUNCTION: To check the line pressure


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 30/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

TECHNICAL SPECIFICATION:

Make : Waaree 

Size of Gauge : 100 mm Dial

Range : 0-7 kg/cm2

End Connection : 3/8” BSP (M)

MOC : SS Body with SS internals

6.B.1.2 PRESSURE GUAGES:

TAG NO: PG – 04 / 05 / 10

INSTRUMENT NAME: Pressure Gauges

LOCATION: 1) Inlet of 5 micron Cartridge Filter

2) Outlet of 5 micron Cartridge Filter

3) Inlet line of EDI System

FUNCTION: To check the line pressure.

TECHNICAL SPECIFICATION:

Make : Waaree

Size of Gauge : 63 mm Dial

Range : 0 – 7 kg/cm2

End Connection : ¼” BSP (M)

MOC : SS Body with SS internals

Damping Liquid : Glycerin

Accuracy : ± 1.6 % of FS
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 31/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

6.B.1.3 PRESSURE GUAGES:

TAG NO: PG – 06 / 07 / 08 / 09 

INSTRUMENT NAME: Pressure Gauges

LOCATION: FOR TWO PASS RO-EDI SYSTEM

1) Feed line of RO pass – I

2) Reject line of RO pass – I

3) Feed line of RO pass – II

4) Reject line of RO pass – II

FUNCTION: To check the line pressure

TECHNICAL SPECIFICATION:

Make : Waaree

Size of Gauge : 63 mm Dial

Range : 0 – 21 kg/cm2

End Connection : 1/4” BSP (M)

MOC : SS Body with SS internals

Damping Liquid : Glycerin

Accuracy : ± 1.6 % of FS

6.B.1.3 PRESSURE GUAGES:

TAG NO: CIP-PG

INSTRUMENT NAME: Pressure Gauges

LOCATION: Discharge line of CIP Feed Pump-1


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 32/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

FUNCTION: To check the line pressure.

TECHNICAL SPECIFICATION: 

Make : Waaree

Size of Gauge : 63 mm Dial

Range : 0 – 7 kg/cm2

End Connection : ¼” BSP (M)

MOC : SS Body with SS internals

Damping Liquid : Glycerin

Accuracy : ± 1.6 % of FS

6.B.2 ROTAMETER:

TAG NO: RM-01 / 02 / 03 / 04 / 05 / 06

INSTRUMENT NAME: Rotameter

LOCATION: 1) Inlet line of Multi Grade Filter (1000 – 10000 LPH)

2) Potable Water Line (500 – 5000 LPH)

3) RO First Pass reject line (200 – 2000 LPH)

4) RO Second Pass reject line (100 – 1000 LPH)

5) EDI Feed line (400 – 4000 LPH)

6) Concentrate line of EDI – I (30 – 300 LPH)

FUNCTION: To check the line flow rate.

TECHNICAL SPECIFICATION:

Make : George Fischer

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 33/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

End Connection : Tri Clover end

Type : Variable Area 

Model : SK

MOC of float : SS 316

MOC of Measuring Tube : SS

MOC of end connection : Nylon 6

Accuracy class : 2.5

6.B.3 FLOW INDICATOR TOTALIZER:

TAG NO: FIT-01

INSTRUMENT NAME: Flow Indicator Totalizer

LOCATION: Outlet of Softeners

FUNCTION: To check the total line flow rate.

TECHNICAL SPECIFICATION:

Make : Aster Technology

Model : FT-650

Line Size : 38 mm

Type : Turbine Type

End Connection : Threaded

6.B.4 FLOATY LEVEL SWITCH:

TAG NO: FLS-01

INSTRUMENT NAME: Floaty Level Switches


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 34/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

LOCATION: Raw Water Tank

FUNCTION: To check the Level in the tank. If the level in the tank is below the desired level the system will

give indication on the panel & will trip the system.

TECHNICAL SPECIFICATION:

Make : Innovative Technologies

Quantity : One

Type : Floaty type

MOC : PVC

6.B.5 LOW LEVEL SWITCH:

TAG NO: LLS-01 / 02 / 03 / 04 / 05

INSTRUMENT NAME: Low Level Switches

LOCATION:

1) NaOCl-01 Dosing Tank

2) Raw Water Tank

3) SMBS dosing system

4) ADS dosing system

5) pH correction system

FUNCTION: To check the Level in the dosing tank. If the level in the tank is below the desired level the

system will give hooter & after settable time will trip the system.

TECHNICAL SPECIFICATION:

Make : Innovative Technology

Quantity : 05 Nos.
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 35/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Type : Magnetic

MOC : PP 

6.B.6 FLOW SWITCHES:

TAG NO: FS-01

INSTRUMENT NAME: Flow Switches

LOCATION: Raw Water inlet line

FUNCTION: To check the line flow.

TECHNICAL SPECIFICATION:

Make : Dag Process

Quantity : One

MOC : SS 316

Size : 1.5”

6.B.7 ORP SENSOR TRANSMITTER & CONTROLLER:

TAG NO: ORP – 01

INSTRUMENT NAME: Oxidation Reduction Potential Analyzer

LOCATION: Inlet of RO pass – I

FUNCTION: ORP Analyzer is provided so as to check the absence/presence of chlorine in the feed water

to the RO System. If free chlorine is sensed in the feed water it will give an indication on the panel &
open the dumping valve and dump the high chlorinated water for 300 secs. & even if the ORP value

is not below the set point it will trip the system.

TECHNICAL SPECIFICATION:

Quantity : One
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 36/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Make : Forbes Marshall

Range : +1000 to – 1000 mV 

End Connection : 1” TC end connection

MOC of Electrode : Glass

6.B.8.1 CONDUCTIVITY SENSOR TRANSMITTER & CONTROLLER:

TAG NO: CIC – 01/02

INSTRUMENT NAME: Conductivity Indicator cum Controller

LOCATION: 1) Outlet of RO pass – I 2) Outlet of RO pass – II

FUNCTION: To check the conductivity in the water, if the conductivity in the feed water is sensed high

above a settable value then it will give an indication on the panel & open the dumping valve and dump the

high conductivity water.

TECHNICAL SPECIFICATION:

Quantity : Two

Make : Emerson

Range : 0 – 200 µs/cm for First Pass Permeate

0 – 100 µs/cm for Second Pass Permeate

End Connection : 1 ½” TC end connection.

MOC : SS 316 wettable parts

6B.8.2 CONDUCTIVITY SENSOR TRANSMITTER & CONTROLLER:

TAG NO: CIC – 03

INSTRUMENT NAME: Conductivity Indicator cum Controller

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 37/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

LOCATION: 1) Outlet of EDI system

FUNCTION: To check the conductivity in the water, if the conductivity in the feed water is sensed high 
above a settable value then it will give an indication on the panel & open the dumping valve and dump the

high conductivity water.

TECHNICAL SPECIFICATION:

Make : Emerson

Range : 0 – 10 µs/cm (EDI outlet)

End Connection : 1 ½” TC end connection.

MOC : SS 316 wettable parts

6. B.9 HIGH PRESSURE SWITCH:

TAG NO: HPS – 01 / 02

INSTRUMENT NAME: High Pressure Switch

LOCATION: 1) Outlet of RO High Pressure – I

2) Outlet of RO High Pressure – II

FUNCTION: To check the feed pressure to the RO system, if the line pressure in the feed water is sensed

high above a settable value then it will trip the entire RO-EDI system.

TECHNICAL SPECIFICATION:

Make : Danfoss

Range : 1 to 16 bar

End Connection : 3/8” BSP (M)

MOC : SS wettable parts

Type : Seamless Bellow type pressure switch

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 38/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

B.10 LOW PRESSURE SWITCH:

TAG NO: LPS – 01 / 02 / 03 

INSTRUMENT NAME: High Pressure Switch

LOCATION:

1) Inlet of RO High Pressure – I

2) Inlet of RO High Pressure – II

3) Inlet of EDI unit

FUNCTION: To check the pressure in the water, if the line pressure in the feed water is sensed low below

the settable value then it will trip the entire RO-EDI system.

TECHNICAL SPECIFICATION:

Make : Danfoss

Range : 0 to 3 bar

End Connection : 3/8” BSP (M)

MOC : SS wettable parts

Type : Seamless Bellow type pressure switch

6. B.11 LEVEL SWITCH for CIP Tank:

TAG NO: CIP – LLS

INSTRUMENT NAME: Low Level Switch

LOCATION: CIP Tank

FUNCTION: To check the Level in the CIP tank. If the level in the tank is below the desired level the system

will give indication on the panel & will trip the system.

TECHNICAL SPECIFICATION:
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 39/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Quantity : One

Make : Mahalaxmi 

Model : SMT-16M 3” TC-AH

MOC : SS 316

6. B.12 TEMPERATURE INDICATOR & TRANSMITTER

TAG NO: CIP – TT

EQUIPMENT NAME: Temperature Transmitter

EQUIPMENT LOCATION: 1) CIP Feed Pump Discharge

FUNCTION: To check Temperature of system during Sanitization Process

TECHNICAL SPECIFICATION:

Make : Wika

Wetted material : SS 316

Range : 0 to 2000 C

Input : PT – 100 (RTD)

Accuracy : + / – 0.5% of F.S.

Ambient Temp : 250 C

B.13 CONTROL VALVES

TAG NO: AV –01 / 02 / 03 / 04 / 05 / 06

EQUIPMENT NAME: Control Valves

LOCATION :

1) Raw Water Inlet line


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 40/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

2) Before RO High Pressure – I (ORP Dump)

3) Reject line of RO pass – I (Auto Rinse Valve) 

4) Permeate line of RO pass – I (CIC Dump)

5) Reject line of RO pass – II (Auto Rinse Valve)

6) Permeate line of RO pass – II (CIC Dump)

FUNCTION: To monitor the plant operation in Auto/Semi-Auto mode as per the pre-set logic & time.

TECHNICAL SPECIFICATION:

Make : Avcon

Type : Y- type Pneumatic operated ON-OFF

MOC : SS Wettable Parts

End Connection : TC end

Size : As per valve schedule

B.14 FLOW DIVERTER VALVE

TAG NO: FDV – 01

EQUIPMENT NAME: Flow Diverter Valve

LOCATION: Outlet of EDI unit.

FUNCTION: To dump the high conductivity water at outlet of EDI unit.

TECHNICAL SPECIFICATION:

Make : Kumar Process

MOC : SS 316L

End Connection : TC end

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 41/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Size : 1”


6.B.15 SAMPLING VALVE:

EQUIPMENT NAME: SP-05 to 11

EQUIPMENT LOCATION: RO-EDI Distribution Piping

FUNCTION: To take a Sample for RO Water Analysis.

TECHNICAL SPECIFICATION:

Quantity : 07 Nos.

Make : Kumar Process

Type : Milipore Design

Size : 8 NB

M.O.C. : SS 316L

6.B.16 VALVE SCHEDULE

Sr. No. Location of Valve Tag No. Size Type MOC

1 Before Raw Water Tank AV-01 32 mm Actuated Valve (NC) SS 304

2 ORP dump valve AV-02 25 mm Actuated Valve (NC) SS 304

RO-I Reject line (Auto


3 AV-03 20 mm Actuated Valve (NC) SS 304
Flushing)

RO-I Conductivity dump


4 AV-04 20 mm Actuated Valve (NC) SS 304
valve

RO-II Reject line (Auto


5 AV-05 20 mm Actuated Valve (NC) SS 304
Flushing)

6 RO-II Conductivity dump AV-06 20 mm Actuated Valve (NC) SS 304


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 42/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

valve

7 Suction line of RWP-01 BV-01 1.5” NB Manual Ball Valve SS 304 

8 Discharge line of RWP-01 BV-02 1.25” NB Manual Ball Valve SS 304

9 Suction line of RWP-02 BV-03 1.5” NB Manual Ball Valve SS 304

10 Discharge line of RWP-02 BV-04 1.25” NB Manual Ball Valve SS 304

11 MGF Inlet BV-05 d40DN32 Manual Ball Valve UPVC

12 MGF outlet BV-06 d40DN32 Manual Ball Valve UPVC

13 MGF back wash inlet BV-07 d40DN32 Manual Ball Valve UPVC

14 MGF back wash outlet BV-08 d40DN32 Manual Ball Valve UPVC

15 MGF drain BV-09 d40DN32 Manual Ball Valve UPVC

16 Softener-01 Inlet BV-10 d40DN32 Manual Ball Valve UPVC

17 Softener-01 Outlet BV-11 d40DN32 Manual Ball Valve UPVC

18 Softener-01 power water BV-12 d25DN20 Manual Ball Valve UPVC

19 Softener-01 brine injection BV-13 d40DN32 Manual Ball Valve UPVC

Softener-01 slow Rinse


20 BV-14 d40DN32 Manual Ball Valve UPVC
outlet

Softener-01 Fast Rinse


21 BV-15 d40DN32 Manual Ball Valve UPVC
outlet

22 Diversion line BV-16 d40DN32 Manual Ball Valve UPVC

23 Discharge ROHP-01 BV-17 25 mm Manual Ball Valve SS 304

24 Discharge ROHP-02 BV-18 25 mm Manual Ball Valve SS 304

Discharge line of Raw Water


25 NRV-01 1.25” Non Return Valve SS 304
Pump – 01

26 Discharge line of Raw Water NRV-02 1.25” Non Return Valve SS 304

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 43/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Pump – 02

27 Conc. Inlet EDI DV-01 DN 20 Diaphragm Valve SS 316 

28 CIP Tank drain valve CIP-DV-01 DN 20 Daiphragm Valve SS 316

29 CIP Suction Valve CIP-DV-02 DN 20 Daiphragm Valve SS 316

30 CIP Discharge Valve CIP-DV-03 DN 20 Diaphragm Valve SS 316

31 ORP needle valve NV-01 ¼” Needle valve SS 304

32 Reject line RO-01 NV-02 20 mm Needle Valve SS 304

33 Reject line RO-02 NV-03 20 mm Needle Valve SS 304

After NaOCl-01 Dosing


34 SP-01 8 NB Sampling Valve SS 304
System

35 Inlet of Multi Grade Filter SP-02 8 NB Sampling Valve SS 304

36 Outlet of Multi Grade Filter SP-03 8 NB Sampling Valve SS 304

37 Outlet of Softener-01 SP-04 8 NB Sampling Valve SS 304

38 After SMBS dosing system SP-05 8 NB Sampling Valve SS 316

39 After ADS dosing system SP-06 8 NB Sampling Valve SS 316

40 After pHC dosing system SP-07 8 NB Sampling Valve SS 316

After 5-micron Cartridge


41 SP-08 8 NB Sampling Valve SS 316
Filter

42 After RO pass-I SP-09 8 NB Sampling Valve SS 316

43 After RO pass-II SP-10 8 NB Sampling Valve SS 316

44 After EDI system SP-11 8 NB Sampling Valve SS 316

6. C.1 PLC PANEL:

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 44/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

TAG NO.: PLC Panel

INSTRUMENT NAME: MCC cum PLC panel. 

LOCATION: Mounted on the SKID

FUNCTION: To operate all Pumps, drives, control valves and instrumentation. To operate predefined

operational logic of the plant. To operate the plant with predefine interlock logic for safety and trouble free

operation. To collect predefine process parameter for equipment validation.

TECHNICAL SPECIFICATION:

MOC of Panel : SS 304 with matt finish

Digital Input and Output Card

Make : Mitsubishi

Model : FX3G 60MR+FX2N 8ER

Digital Input : 40, 24VDC input

Digital Output : 28, 230VAC output

Analog Input/Output Card

Make : Mitsubishi

Model : FX2N 8AD + 5A

Analog Input : 12 Nos.

Analog Output : 01 No.

MMI ( Monochrome)

Make : Mitsubishi

Catalogue No. : E – 1043

Communication Port : RS-232 (DF1)

Printer Port : RS-232


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 45/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Display : Touch Screen

Size : 3.5” 

6.C.2 PLC INPUT/OUTPUT DETAILS:

Output
Sr.No D/Input Input Description D/Output
description

1 X0 RWP-01 start/stop Y0 NaOCl-01

2 X1 RWP-01 trip Y1 SMBS-01

3 X2 RWP-02 start/stop Y2 ADS-01

4 X3 RWP-02 trip Y3 PHC-01

5 X4 LLS NaOCl-01 Y4 RWP-01

6 X5 FS-01 Y5 RWP-02

HL – Raw Water
7 X6 Y6 ROHP-01
Tank

ML – Raw Water
8 X7 Y7 ROHP-02
Tank

9 X10 LL – Raw Water Tank Y10 EDI

10 X11 ROHP 1 start/stop Y11 PLP-01

11 X12 ROHP 1 trip Y12 PLP-02

12 X13 ROHP 2 start/stop Y13 HIUV

13 X14 ROHP 2 trip Y14 PWST Heater

14 X15 EDI start/stop Y15 CIPFP

15 X16 EDI trip Y16 CIP Heater

16 X17 CIPFP start/stop Y17 AV-01

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 46/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

17 X20 CIPFP trip Y20 AV-02

18 X21 CIP HTR Start / Stop Y21 AV-03 

19 X22 LLS SMBS-01 Y22 AV-04

20 X23 LLS ADS-01 Y23 AV-05

21 X24 LLS-pHC-01 Y24 AV-06

22 X25 LPS-01 ROHP-01 Y25 FDV-01

23 X26 LPS-02 ROHP-02 Y26 PWD-FDV-01

24 X27 LPS-03 EDI Y27 PWD-AV-01

25 X30 HPS-01 ROHP-01 Y30 VF HTR

26 X31 HPS-02 ROHP-02 Y31 Hooter

27 X32 LLS CIPT Y32 Spare

28 X33 PLP 1 start / stop Y33 Spare

29 X34 PLP 2 start / stop

30 X35 PLP 1/2 trip

PWST Ceramic
31 X36
Heater

Auto Manu. Switch


32 X37
for RO-EDI

Auto Manu. Switch

33 X40 for Purified Water


Distribution System

34 X41 EMERGENCY

35 X42 ACCEPT

36 X43 Air Pressure Switch

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 47/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

37 X44 Spare

38 X45 Spare 

39 X46 Spare

40 X47 Spare

Analog Analog A/O


Sr.No A/I description
Input Output description

1 AI-1 PWG – ORP 01 AO-1 PLP – VFD

2 AI-2 PWG – CIC 01

3 AI-3 PWG – CIC 02

4 AI-4 PWG – CIC 03

5 AI-5 PWD – CIC 01

6 AI-6 PWD – FT 01

7 AI-7 PWD – TT 01

8 AI-8 PWD – LIC

9 AI-9 CIP TIC

10 AI-10 EDI Current

6.C.3 System Description & Process Logics for Purified water Generation System

Audio
Sr. Indication on
Interlock Description Action Taken Visual
No. MMI
Alarm

High Level in Raw Water


1 Will close Actuated Valve AV-01 YES YES
Tank

Medium Level in Raw


2 Will open Actuated Valve AV-01 YES NA
Water Tank

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 48/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

3 Low Level in Raw Water Will stop RWP-01 / 02 YES YES


Tank

Medium Level in Raw
4 Will start RWP-01 / 02 YES NA
Water Tank

Low Level in NaOCl-01 Will trip NaOCl-01 Dosing Pump & will
5 YES YES
Dosing Tank. close AV-01

Low flow in Raw Water Will trip NaOCl-01 Dosing Pump & will
6 YES YES
inlet line close AV-01

High Totalized flow at


7 It Should give Alarm for Regeneration. YES YES
outlet of softener

8 Emergency Stop Should Trip the System. YES YES

Low level in SMBS 1 RWP-01 will stop & RO-EDI System


9 YES YES
Dosing tank will stop.

Low level in ADS Dosing RWP-01 will stop & RO-EDI System
10 YES YES
tank will stop.

Low Level in pH RWP-01 will stop & RO-EDI System


11 YES YES
Correction Dosing tank will stop.

12 High ORP-01 Value. 1) Free chlorine will pass through and

ORP sensor will sense free chlorine.


Inturn the ORP value will increase

above the set point. This will open the YES YES
ORP dumping valve AV-02.

2) ORP comes down within the


desired limit. After 30 secs. of
consistent reading, below the set

value it will close the AV-02. Allow the

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 49/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

water to feed to the RO system. The


entire system will start automatically.
YES NA 

3) If the ORP value is high for

more than 300 secs. it will trip the


plant.

YES YES

13
Low Pressure at ROHP –
This will trip the ROHP – 01 YES YES
01 suction

Repeated Low Pressure After ROHP – 01 trips for 4 times in a


14 YES YES
at ROHP – 01 suction minute. This will trip the entire plant.

High Pressure at ROHP


15 RO – EDI system will trip. YES YES
–01 discharge

16 High Conductivity at RO 1) If the conductivity is above the YES YES

pass – I outlet set point, it will open the dumping


valve AV-04.

2) After 30 secs. of consistent


reading, below the set value, it will

close the AV-04. Allow the water to


YES NA
feed to the 2nd Pass of RO system.
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 50/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

The entire system will start


automatically.

3) If the RO pass-I outlet

conductivity is high for more than 300


secs. It will trip the plant.

YES YES

Low Pressure at ROHP –


17 This will trip the ROHP – II YES YES
II

High Pressure in ROHP –


18 RO – EDI system will trip. YES YES
II discharge

19 High Conductivity at RO 1) If the conductivity is above the YES YES


pass – II outlet set point, it will open the dumping

valve AV-06.

2) After 30 secs. of consistent


reading, below the set value, it will

close the AV-06. Allow the water to


feed to the EDI system. The entire

system will start automatically. YES NA

3) If the RO pass-II outlet


conductivity is high for more than 300

secs. it will trip the plant.

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 51/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

YES YES 

YES
Low pressure at EDI inlet, will trip EDI
20 Low pressure at EDI inlet YES
unit.

YES YES

1) If the conductivity is above the


set point, it will open the dumping

valve FDV-01.

2) After 30 secs. of consistent


reading below the set value, it will

close the FDV-01. Allow the water to


High Conductivity at EDI
21 feed to the purified water tank. The YES NA
outlet
entire system will start automatically.

3) If the EDI outlet conductivity is

high for more than 300 secs. it will trip


the plant.

YES YES

Low temperature at CIP


22 Ceramic Heater will be ON. YES NA
supply line

High temperature at CIP


23 Ceramic Heater will be OFF. YES NA
supply line
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 52/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

24 Low Level in CIP Tank Should trip the Heater & CIP Feed YES YES
Pump.

25 Emergency Stop RO-EDI System will trip. YES YES

7. DRAWINGS REQUIRED

SR. NO. DESCRIPTION DRAWING NO. REV

P&ID for Pretreatment & Purified Water


1 HPS/PR150/PWG/DR01 0
Generation & Distribution System

2 Skid Drawings HPS/PR150/PWG/DR02 0

3 Isometric for Pretreatment System HPS/PR150/PWG/DR03 0

4 Isometric for RO-EDI System HPS/PR150/PWG/DR04 0

5 Control Panel Drawing HPS/PR150/PWG/DR05 0

6 CIP Tank Drawing HPS/PR150/PWG/DR06 0

8. SUPPORTING UTILITIES

SR. Equipments /
Location Utilities Specification Scope
NO. Instruments

PW Generation
1 Pretreatment Plant Raw Water 7000 LPH ZCHL
Plant

Control Panel RO Plant Room Power 3 phase, 430V, 50 Hz ZCHL

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 53/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance


Compressed ZCHL
MOC of tube is PU,
3 RO Plant RO Plant Room Filtered regulated
Press – 6 kg/cm2
Air

9. PRE-QUALIFICATION CHECK LIST

9.1 HYDRAULIC PRESSURE TEST

9.2 DOCUMENTATION CHECK

9.3 INTERLOCK CHECKS

9.4 OPERATIONAL CHECKS

10. LIST OF DOCUMENTS REQUIRED FOR GENERATION SYSTEM

CODE DOCUMENTS REQUIRED

A Manufacturer’s Manuals – Preventive Maintenance (O.M.)

B MOC Certificate

C Leak Test Reports / Hydro Test Report

D Sanitization Reports

E Cleaning / Flushing Reports

F Manufacturer’s Catalogue

G Test Certificate

H Guarantee / Warranty Certificate

I Basis of Design

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 54/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

11. DESIGN QUALIFICATION REPORT

APPROVAL 

Approved / Not Approved

Approved By Signature

Vendor Executive name

Engineering

Client

Head-Operations

Head-Quality

Abbreviation
Description

URS User Required Specification

FRS Functional Required Specification

cGMP Current Good Manufacturing Practice

QA Quality Assurance

USP United States Pharmacopoeia

WHO World Health Organization

ROHP RO High Pressure Pump


Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 55/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

CIPFP CIP Feed Pump

SMBS Sodium Meta bisulfate 

ADS Antiscalent dosing System

pHC pH Correction

CF Cartridge Filter

RO Reverse Osmosis

EDI Electro-Deionization

CIP Cleaning In Place

Ppm Mg/Ltrs OR Parts Per Million

NTU Neblometric Turbidity Unit

MWCO Molecular Weight Cut-Off

CFU/ml Colony Forming Unit per ml

TSS Total Suspended Solids

TDS Total Dissolved Solids

TOC Total Organic Carbon

TVC Total Viable Count

TBC Total Bacterial Count

TC Tri Clover

P&ID Process Flow & Instrumentation Diagram

LPH Liters Per Hour

12. ABBREVIATIONS

PG Pressure Gauge

RM Rotameter
Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 56/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

LLS Low Level Switch

PLC Programmable Logical Controls 

MMI Manual Machine Interface

ORP Oxidation Reduction Potential

CIC Conductivity Indicator cum Controller

HPS High Pressure Switch

LPS Low Pressure Switch

MOC Material Of Construction

CPVC Chlorinated Poly-Vinyl Chloride

SS Stainless Steel

PP Poly-Propylene

FRP Fiber Reinforced Plastic

HDPE High Density Poly Ethylene

HOS Height Of Shell

For More Pharma Updates Visit –https://pharmaguidances.com

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 57/58
12/3/2020 DQ for Purified Water System - Pharmaceutical Guidance

Pharmaceutical Guidanace
Mr. Shiv Kumar is the Author and founder of pharmaceutical guidance, he is a pharmaceutical Professional from India having more than 14 years of
rich experience in pharmaceutical field.
During his career, he work in quality assurance department with multinational company’s i.e Zydus Cadila Ltd, Unichem Laboratories Ltd, Indoco 
remedies Ltd, Panacea Biotec Ltd, Nectar life Science Ltd. During his experience, he face may regulatory Audit i.e. USFDA, MHRA, ANVISA, MCC,
TGA, EU –GMP, WHO –Geneva, ISO 9001-2008 and many ROW Regularities Audit i.e.Uganda,Kenya, Tanzania, Zimbabwe. He is currently leading
a regulatory pharmaceutical company as a head Quality. You can join him by Email, Facebook, Google+, Twitter and YouTube

Privacy & Cookies Policy

https://pharmaguidances.com/dq-for-purified-water-system/ 58/58

You might also like