Download as pdf or txt
Download as pdf or txt
You are on page 1of 33

Report No.

: AGC02955190401TE01
Page 34 of 66

EUT: JRH4029-WH Test Date: May 30, 2019

Temperature: 250C Tested by: Draven


Humidity: 55 % RH Operation Mode: GFSK
Test Voltage High Voltage

Low Channel-Frequency Band 1 (30 MHz ≦ f ≦ 1000 MHz)


Report No.: AGC02955190401TE01
Page 35 of 66

Low Channel-Frequency Band 2 (1000 MHz < f ≦ 2387 MHz)

Low Channel-Frequency Band 3 (2387 MHz < f ≦ 2400 MHz)


Report No.: AGC02955190401TE01
Page 36 of 66

Low Channel-Frequency Band 4 (2483.5 MHz ≦ f < 2496.5 MHz)

Low Channel-Frequency Band 5 (2496.5 MHz ≦ f < 12.5 GHz)


Report No.: AGC02955190401TE01
Page 37 of 66

Middle Channel-Frequency Band 1 (30 MHz ≦ f ≦ 1000 MHz)

Middle Channel--Frequency Band 2 (1000 MHz < f ≦ 2387 MHz)


Report No.: AGC02955190401TE01
Page 38 of 66

Middle Channel--Frequency Band 3 (2387 MHz < f ≦ 2400 MHz)

Middle Channel--Frequency Band 4 (2483.5 MHz ≦ f < 2496.5 MHz)


Report No.: AGC02955190401TE01
Page 39 of 66

Middle Channel--Frequency Band 5 (2496.5 MHz ≦ f < 12.5 GHz)

High Channel--Frequency Band 1 (30 MHz ≦ f ≦ 1000 MHz)


Report No.: AGC02955190401TE01
Page 40 of 66

High Channel--Frequency Band 2 (1000 MHz < f ≦ 2387 MHz)

High Channel--Frequency Band 3 (2387 MHz < f ≦ 2400 MHz)


Report No.: AGC02955190401TE01
Page 41 of 66

High Channel--Frequency Band 4 (2483.5 MHz ≦ f < 2496.5 MHz)

High Channel--Frequency Band 5 (2496.5 MHz ≦ f < 12.5 GHz)


Report No.: AGC02955190401TE01
Page 42 of 66

5.4. ANTENNA POWER ERROR MEASUREMENT


5.4.1. LIMIT

Item Limits

≦3mW/MHz (FH form 2427 - 2474.75 MHz)


Antenna Power
≦10mW/MHz (OFDM,DS from2400~2483.5MHz)
Density
≦10mW/MHz(Other from 2400~2483.5MHz)
+20%, -80% (Base on manufacturer declare antenna power
Antenna Power Error
density)

5.4.2. MEASURING INSTRUMENTS AND SETTING


Please refer to section 5 in this report. The following table is the setting of Spectrum Analyzer.
Spectrum Parameter Setting

Attenuation Auto

RBW / VBW 1 MHz

Detector Peak

Trace Max Hold

Sweep Time Auto


Report No.: AGC02955190401TE01
Page 43 of 66

5.4.3. TEST PROCEDURES


1. A power meter is connected on the IF output port of the spectrum analyzer.
2. Adjust the spectrum analyzer to have the center frequency the same with the
measured carrier. RBW=VBW=1MHz, detector mode is positive peak. Turn
off the averaging function and use zero span.
3. The calibrating signal power shall be reduced to 0 dBm and it shall be verified
that the power meter reading also reduces by 10 dB.
4 . Connect the equipment to be measured. Using the following settings of the
spectrum analyzer in combination with "max hold" function, find the frequency
of highest power output in the power envelope: center frequency equal to
operating frequency; RBW & VBW: 1 MHz; detector mode: positive peak; averaging:
off; span: 3 times the spectrum width; amplitude: adjust for middle of the
instrument' range. The frequency found shall be recorded.
5 . Set the center frequency of the spectrum analyzer to the found frequency and switch
to zero span. The power meter indicates the measured power density “E”.
6. Remove the EUT and put the replacing standard signal generator (SSG). Set
the standard signal generator (SSG) at same frequency and transmit on, then set
SSG output power at Pt to give the equivalent output level of “E”.
7. Calculate antenna power density by the formula below PD = Pt + 10*log(1/x).
x: The duty cycle of the EUT in continuously transmitting mode
Pt: Output power of the SSG
8. Antenna Power Error is definition that actual measure antenna power tolerance
between + 20% to - 80% power range that base on manufacturer declare the
conducted power density.

5.4.4. TEST SETUP LAYOUT

5.4.5. EST DEVIATION


There is no deviation with the original standard.

5.4.6. EUT OPERATION DURING TEST


The EUT was programmed to be in continuously transmitting mode.
Report No.: AGC02955190401TE01
Page 44 of 66

5.4.7. TEST RESULT OF ANTENNA POWER ERROR


Transmitting mode:
EUT: JRH4029-WH Test Date: May 30, 2019

Temperature: 250C Tested by: Draven

Humidity: 55 % RH

Conducted RF output
Rated power Antenna Power
Test Voltage Test Frequency power
(mW/MHz) Error (%)
(mW/MHz)
2446MHz 0.021 0.03 -30.00

4.50V 2461MHz 0.026 0.03 -13.33

2476MHz 0.020 0.03 -33.33

2446MHz 0.018 0.03 -40.00

4.05V 2461MHz 0.022 0.03 -26.67

2476MHz 0.017 0.03 -43.33

2446MHz 0.024 0.03 -20.00

4.95V 2461MHz 0.020 0.03 -33.33

2476MHz 0.017 0.03 -43.33

Limit : +20%, -80% (Base on manufacturer declare antenna power density)


Report No.: AGC02955190401TE01
Page 45 of 66

5.5. IMITATION OF COLLATERAL EMISSION OF RECEIVER MEASUREMENT


5.5.1. LIMIT

Item Limits

≦4nW (f<1GHz)
RX Spurious
Emission:
≦20nW (1GHz≦f)

5.5.2. MEASURING INSTRUMENTS AND SETTING

Please refer to section 5 in this report. The following table is the setting of Spectrum Analyzer.
Spectrum Parameter Setting

Attenuation Auto
100 kHz (below 1GHz emissions)
RB
1 MHz (above 1GHz emissions)
100 kHz (below 1GHz emissions)
VB
1 MHz (above 1GHz emissions)
Detector Peak

Trace Max Hold

Sweep Time Auto

5.5.3. TEST PROCEDURES


1. EUT have the continuous reception mode and fixed only one channelize.
2. Setting of SA is following as RB / VB: 100 kHz (below 1GHz emissions) / 1 MHz
(above 1GHz emissions) /
AT: 10dB / Ref: 0dBm / Sweep time: Auto / Sweep Mode: Continuous sweep / Detect
mode: Positive peak / Trace mode: Max hold
3. SA set RB: 100kHz and VB: 100kHz. Then adjust to start frequency 30MHz and
stop frequency 1000MHz. Search to mark peak reading value + cable loss shall
be less than 4nW
4. SA set RB: 1MHz and VB: 1MHz. Then adjust to start frequency 1000MHz and
stop frequency 12500MHz. Search to mark peak reading value + cable loss shall
be less than 20nW
5. If power level of lower emissions are more than 1/10 of limit (.0.4nW for f < 1GHz,
2nW for f >= 1GHz), all those are to be indicated in the 2nd and 3rd lines. If others
are 1/10 or less more of the limit, no necessary to be indicated.
Report No.: AGC02955190401TE01
Page 46 of 66

5.5.4. TEST SETUP LAYOUT

5.5.6. TEST DEVIATION


There is no deviation with the original standard.

5.5.7. EUT OPERATION DURING TEST


The EUT was programmed to be in continuously reception mode.

5.5.8. TEST RESULT OF LIMITATION OF COLLATERAL EMISSION OF RECEIVER

EUT: JRH4029-WH Test Date: May 30, 2019

Temperature: 250C Tested by: Draven

Humidity: 55 % RH

Note: The worst test channel of all channels was showed as the follow:
Report No.: AGC02955190401TE01
Page 47 of 66

Test Voltage: 4.95V


RX-Frequency Band 1 (30 MHz ≦ f < 1000 MHz)

RX-Frequency Band 2 (1000 MHz ≦ f < 12500 MHz)


Report No.: AGC02955190401TE01
Page 48 of 66

Test Voltage: 4.50V


RX-Frequency Band 1 (30 MHz ≦ f < 1000 MHz)

RX-Frequency Band 2 (1000 MHz ≦ f < 12500 MHz)


Report No.: AGC02955190401TE01
Page 49 of 66

Test Voltage: 4.05V


RX-Frequency Band 1 (30 MHz ≦ f < 1000 MHz)

RX-Frequency Band 2 (1000 MHz ≦ f < 12500 MHz)


Report No.: AGC02955190401TE01
Page 50 of 66

5.6. TRANSMISSION ANTENNA GAIN (EIRP ANTENNA POWER) MEASUREMENT


5.6.1. LIMIT

Item Limits

≦6.91dBm/MHz (FH form 2427 - 2474.75 MHz)


EIRP Power Density ≦12.14dBm/MHz (OFDM,DS from 2400~2483.5MHz)
≦12.14dBm (Other from 2400~2483.5MHz)

Note: This test item is not applied for radio equipment with equivalent isotropic radiation power
lower than 12.14dBm/MHz, but Antenna Power(Conducted) limit is 10 mW/MHz (10
dBm/MHz), So the test item will not be applied to the transmission antenna which has a gain of
2.14dBi or less

5.6.2.MEASURING INSTRUMENTS AND SETTING


Please refer to section 5 in this report. The following table is the setting of spectrum analyzer.
Spectrum Parameter Setting

Attenuation Auto

RBW/VBW 1 MHz

Detector Peak

Trace Max Hold

Sweep Time Auto

5.6.3.TEST PROCEDURES
1. Set EUT ad measuring antenna at the same height and roughly facing each other.
2. Move the measuring antenna height up and down within ± 50cm of EUT height and
swing it to find the maximum output of the measuring antenna. The output level at
the spectrum analyzer is read sa “E“.
3. Remove the EUT from the turn table and put the replacing antenna facing to
measuring antenna at same height. Set the standard signal generator (SSG) at
same frequency and transmit on then receive the signal
4. Swing the replacing antenna give a maximum receiving level.
5. Move the measuring antenna height up and down within ± 50cm of replacing
antenna height and swing it to find the maximum receiving level.
6. Set SSG output power at Pt to give the equivalent output level of “E” or calculate
Pt with SSG output which gives the nearest of “E” and difference (± 1dB). Record
the Pt.
7. Calculate EIRP by the formula below EIRP = Gt – L + Pt.
Gt: gain of replacing antenna (dBi)
L: feeder loss between SSG and replacing antenna
Pt: Output power of the SSG
8. If the antenna for the EUT has circular polarization, sum of V-field and H-field
will be result if measuring antenna is linear polarization.
Report No.: AGC02955190401TE01
Page 51 of 66

5.6.4. TEST SETUP LAYOUT


For EUT radiation measurement

For standard antenna measurement

5.6.5. TEST DEVIATION


There is no deviation with the original standard.

5.6.6. EUT OPERATION DURING TEST


The EUT was programmed to be in continuously transmitting mode.

5.6.7. RESULTS OF TRANSMISSION ANTENNA GAIN


Note: refer to section 5.6.1 the test item is not applicable.
Report No.: AGC02955190401TE01
Page 52 of 66

5.7. TRANSMISSION RADIATION ANGLE WIDTH (3DB BEAMWIDTH) MEASUREMENT


5.7.1. LIMIT

Item Limits

360/A (If A<1; then A=1)


3dB antenna beam width A = {EIRP Power [mW] / 16.36 for DS, OFDM} or
A = {EIRP Power [mW] / 4.9 for FH}

Note: This test item is not applied for radio equipment with equivalent isotropic radiation power
lower than 12.14dBm/MHz, but Antenna Power(Conducted) limit is 10 mW/MHz (10
dBm/MHz), So the test item will not be applied to the transmission antenna which has a gain of
2.14dBi or less

5.7.2. MEASURING INSTRUMENTS AND SETTING

Spectrum Parameter Setting

Attenuation Auto

Span Frequency 0 MHz

RBW 1 MHz

VBW 1 kHz

Detector Peak

Trace Max Hold

Sweep Time Auto

5.7.3. TEST PROCEDURES


1. Set EUT and measuring antenna at the same height and roughly facing each other.
2. Set spectrum analyzer with condition in section 4.7.2 and tune reference level to
observe receiving signal position.
3. Rotate directions of the EUT horizontally and vertically to find the maximum
receiving power.
4. Move the measuring antenna height up and down within ± 50cm of EUT height and
swing it to find the maximum output of measuring antenna. The output level at the
spectrum analyzer is read as “E”
5. Calculate permitted radiation angle in horizontal and vertical using EIRP
measured in another test method.
6. Calculate 3dB antenna beam width by the formula below 360/A (If A<1; then A=1).
A = {EIRP Power [mW] / 16.36 for DS, OFDM} or
A = {EIRP Power [mW] / 4.9 for FH}
Report No.: AGC02955190401TE01
Page 53 of 66

5.7.4. TEST SETUP LAYOUT

5.7.5. TEST DEVIATION


There is no deviation with the original standard.

5.7.6. EUT OPERATION DURING TEST


The EUT was programmed to be in continuously transmitting mode.

5.7.7. TEST RESULT OF TRANSMISSION RADIATION ANGLE WIDTH (3DB BEAMWIDTH)


Note: refer to section 5.7.1 the test item is not applicable.
Report No.: AGC02955190401TE01
Page 54 of 66

5.8. RADIO INTERFERENCE PREVENTION CAPABILITY MEASUREMENT


5.8.1. LIMIT

Item Limits

Identification code ≧48 bits

5.8.2. MEASURING ID CODE SOFTWARE

Item Limits

MAC IP List MAC Scan

5.8.3. TEST PROCEDURES


1. In the case that the EUT has the function of automatically transmitting the
identification code: a. Transmit the predetermined identification codes form EUT. b.
Check the transmitted identification codes with the demodulator.
2. In the case of receiving the identification ocde: a. Transmit the
predetermined identification codes form the counterpart. b . Check if communication
is normal. c. Transmit the signals other than predetermined ID codes form
the counterpart. d. check if the EUT stops the transmission, or if it displays
that idnetification codes are different from the predetermined ones.

5.8.4. TEST SETUP LAYOUT

5.8.5. TEST DEVIATION


There is no deviation with the original standard.

5.8.6. EUT OPERATION DURING TEST


The EUT was programmed to be in normal transmitting mode.
Report No.: AGC02955190401TE01
Page 55 of 66

5.8.7. TEST RESULT OF RADIO INTERFERENCE PREVENTION CAPABILIT

EUT: JRH4029-WH Test Date: May 30, 2019

Temperature: 250C Tested by: Draven


Humidity: 55 % RH Operation Mode: GFSK
Test result: CONFORM
Report No.: AGC02955190401TE01
Page 56 of 66

5.9. HOPPING FREQUENCY DWELL TIME MEASUREMENT


5.9.1. LIMIT
Item Limits
Hopping Freq. Dwell Time ≦ 0.05sec (In 0.4 sec × spreading rate)

5.9.2. MEASURING INSTRUMENTS AND SETTING


Please refer to section 5 in this report. The following table is the setting of the
spectrum analyzer.

Spectrum Parameter Setting


Attenuation Auto
Span Frequency 0 MHz
RB 1 MHz
VB 1 MHz
Detector Peak
Trace Max Hold
Sweep Continuous

5.9.3. TEST PROCEDURES


a. The transmitter output (antenna port) was connected to the spectrum analyzer
b. Set RBW of spectrum analyzer to 1MHz and VBW to 1MHz.
c. Use a video trigger with the trigger level set to enable triggering only on full pulses.
d. Sweep Time is more than once pulse time.
e. Set the center frequency on any frequency would be measure and set the frequency span to
zero span.
f. Measure the maximum time duration of one single pulse.
g. Set the EUT for GFSK packet transmitting.
h. Measure the maximum time duration of one single pulse.
i. Dwell time = 0.4 x (Spread Spectrum Factor)x(duty cycle)/ (No. of hopping channels)]

5.9.4. TEST SETUP LAYOUT


Report No.: AGC02955190401TE01
Page 57 of 66

5.9.5. EUT OPERATION DURING TEST


The EUT was programmed to be in transmitting mode.

5.9.6. TEST RESULT OF HOPPING FREQUENCY DWELL TIME


EUT: JRH4029-WH Test Date: May 30, 2019
Temperature: 250C Tested by: Draven
Humidity: 55 % RH Operation Mode: GFSK

Test Mode Hopping

Data Packet 90% Spread BW sending time of burst Dwell Time Limits
(Worst case) (MHz) burst (s) cycle (s) (s) (s)

GFSK 31.237 0.0006694 0.06407 0.03264 0.05

Duty-cycle = [on time/total time] x 100%


Spreading rate=Spread BW/transmission rate
Modulation rate of EUT is 2Mbps
Dwell time = (0.4(s) x spreading rate x sending time of burst(s)) / (burst cycle(s) x No. of hopping channel)
Measures the Sending time of burst
Report No.: AGC02955190401TE01
Page 58 of 66

Measures the Burst cycle

Spread BW
Report No.: AGC02955190401TE01
Page 59 of 66

5.10. CONSTRUCTION PROTECTION CONFIRMATION METHOD

5.10.1. LIMIT
The high-frequency section and modulation section of the radio equipment except for
the antenna system shall not be capable of being opened easily.

5.10.2. CONFIRMATION METHOD

The RF and modulation portions are protected against illegal modification as following method:

Protected Method Description

2.4G Module Package of RF (MX5323) and Modulation (TX:


IC Package
16MHz) portions is BGA type.
The upper enclosure is blocked through buckles, the
Enclosure enclosure is not easily open, otherwise, the device will be
damage.
we will add some warning statements on the user manual to
User manual
against illegal modification
Report No.: AGC02955190401TE01
Page 60 of 66

APPENDIX A: PHOTOGRAPHS OF THE TEST SETUP


Report No.: AGC02955190401TE01
Page 61 of 66

APPENDIX B: PHOTOGRAPHS OF THE EUT


ALL VIEW OF EUT

TOP VIEW OF EUT


Report No.: AGC02955190401TE01
Page 62 of 66

BOTTOM VIEW OF EUT

FRONT VIEW OF EUT


Report No.: AGC02955190401TE01
Page 63 of 66

BACK VIEW OF EUT

LEFT VIEW OF EUT


Report No.: AGC02955190401TE01
Page 64 of 66

RIGHT VIEW OF EUT

OPEN VIEW OF EUT-1


Report No.: AGC02955190401TE01
Page 65 of 66

OPEN VIEW OF EUT-2

INTERNAL VIEW OF EUT-1

Antenna
Report No.: AGC02955190401TE01
Page 66 of 66

INTERNAL VIEW OF EUT-2

INTERNAL VIEW OF EUT-3

----END OF REPORT----

You might also like