Introduction
This door access system complements our multi-apartment door entry
systems perfectly and allows the user to open the door using a keyfob,
password, or keyfob plus password.
Specification
Working Voltage ....................... 12V DC
Unlock current .......................... up to 1A
Static current ............................. up to 60mA
Reading distance ....................... 0 – 10cm
RF Type ..................................... EM 125kHz
Working temperature ............... -10°C to +70°C
Humidity range ......................... 10% to 90% non-condensing
Dimensions................................ 117 x 117 x 21mm
J2 This is used to select a high voltage (12V) or low voltage (2V) for
lock operation. This is supplied set to 12V and should be left like
this for all 4tronix locks
S16 This is only used to reset the master password. See following
instructions. Leave connected between Pin1 and Pin2.
Page 2
Installing the System
Page 3
Configuring the System
A. Entering & Exiting System Configuration mode
B. Changing the master password
C. Add new user (keyfob entry)
D. Add new user (password entry)
E. Add new user (keyfob plus password entry)
F. Remove one user
G. Remove all users
H. Set door open time
I. Reset Master Password
Page 4
C: Add New User (Keyfob entry)
1. Enter system configuration mode (see A above)
2. Press
3. Enter the 4 digit unique User ID
4. Place user’s keyfob near the keypad Buzzer sounds once
5. New keyfob user has been added
6. If the buzzer sounds three times and lights return then
the user was already logged into the system. Try deleting the user,
then re-adding
7. If the buzzer sounds four times, then the memory is full and all
250 possible users are stored. You must delete some users first
before adding new ones.
Page 5
E: Add New User (Keyfob plus Password entry)
1. Enter system configuration mode (see A above)
2. Press
3. Enter the 4-digit unique User ID
4. Place user’s keyfob near the keypad Buzzer sounds once
5. Enter the 6-digit user-specific password Buzzer sounds once
6. New password user has been added
7. If the buzzer sounds three times and lights return to
then the user was already logged into the system. Try deleting the
user, then re-adding
8. If the buzzer sounds four times, then the memory is full and all
250 possible users are stored. You must delete some users first
before adding new ones.
Page 6
H: Set Door Open Time
1. Enter system configuration mode (see A above)
2. Press
3. Press 2 keys for door open time in seconds. So, for the lock to
remain open for 5 seconds, enter then
4. Door open time is changed
Page 7
Single Keypad with electric lock/release and exit switch
Page 8