Pile Design Using SPT

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 7

Design of Micropile GEOPROFOUND ENGINEERING SDN BHD

Pile Geotechnical Design using SPT Values


Site:
Round Pile f = 400 mm Skin Area per 1.257 Base Area, Ab = 0.126 m2
Factor of Safety (FoS) = 2.000
Unit End Bear at
Skin Skin Cumulative depth, End Bear at Pile Ultimate Pile Allowable Pile Capacity (kN)
Depth Avg SPT Capacity, Qult = Capacity, Qall =
Fric, fs Fric, Fs Skin Fric, Fs qb=min(400N/3 depth, Qb
Interval (m) Value, N
= 2N (kN) (kN) , 10000) (kN) Fs+Qb (kN) Qult/FoS (kN)
(kN/m2) (kN/m2) 0 1000 2000 3000 4000 5000
0
33 30 60 2488.1 2488.1 4000.0 502.7 2990.8 1495.4
2 50 100 -3895.6 -1407.4 6666.7 837.8 -569.7 -284.8
3 2 4 5.0 -1402.4 266.7 33.5 -1368.9 -684.4
4 2 4 5.0 -1397.4 266.7 33.5 -1363.9 -681.9 5
10 11 22 165.9 -1231.5 1466.7 184.3 -1047.2 -523.6
6 13 26 -130.7 -1362.2 1733.3 217.8 -1144.4 -572.2
7 26 52 65.3 -1296.8 3466.7 435.6 -861.2 -430.6 10
8 21 42 52.8 -1244.1 2800.0 351.9 -892.2 -446.1
9 21 42 52.8 -1191.3 2800.0 351.9 -839.4 -419.7

Depth (m)
10 1 2 2.5 -1188.8 133.3 16.8 -1172.0 -586.0
11 12 24 30.2 -1158.6 1600.0 201.1 -957.6 -478.8 15
12 5 10 12.6 -1146.1 666.7 83.8 -1062.3 -531.1
13.5 6 12 22.6 -1123.4 800.0 100.5 -1022.9 -511.5
15 6 12 22.6 -1100.8 800.0 100.5 -1000.3 -500.1
20
16.5 1 2 3.8 -1097.0 133.3 16.8 -1080.3 -540.1
18 3 6 11.3 -1085.7 400.0 50.3 -1035.5 -517.7
19.5 1 2 3.8 -1082.0 133.3 16.8 -1065.2 -532.6
21 2 4 6.8 -1075.2 240.0 30.2 -1045.0 -522.5 25
23 50 100 251.3 -823.9 6666.7 837.8 13.9 7.0
24 55 2464.8 3097.3 2273.4 10000.0 1256.6 3530.1 1765.0

30

Specified Working Load = 2000 kN Depth required = 10.5 m


35
(Based on given BH/MKT Report & above FoS)

12/04/2020
Design of Micropile GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Micropile Structural Capacity Calculation

Pile Diameter, f = 400 mm


Grade, fcu 35 cement grout (w/c ratio = 0.45)
Use API Pipe, f 88.9 mm 6.45 mm thk
fy = 500 N/mm2 (min)

Area of Steel & Concrete


As (provided) = 2prt
As = 1670.7068 mm2
Ac = p*d2/4
Ac = 125680 mm2

Ultimate Axial Load,


fu = 0.4fcu*Ac + 0.75fy*As
fu = 2386035.1 N
fu = 2386.03506 kN

Taking Factor of Safety (FoS) = 2


fall = fu/FoS
fall = 1193.0 kN
Based on the structural capacity above, the micropile is able to take the given working load
of 1193.0 kN

Micropile Details

Micropile, Dia 400 mm

API Pipe inside


f 88.9
6.45 mm thk

Clear spacing/Cover = 155.6 mm

12/04/2020
Design of Micropile GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Cement grout, G 35 N
W/C Ratio 0.45 min

12/04/2020
Design of Micropile GEOPROFOUND ENGINEERING SDN BHD (707134-T)

12/04/2020
Design of Micropile GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Micropile Structural Capacity Calculation

Pile Diameter, f = 400 mm


Grade, fcu 35 cement grout (w/c ratio = 0.45)
Use Rebar, f 32 mm 25 Nos
fy = 460 N/mm2 (min)

Area of Steel & Concrete


As (provided) = Sprbars2
As = 20106.193 mm2
Ac = p*d2/4
Ac = 125680 mm2

Ultimate Axial Load,


fu = 0.4fcu*Ac + 0.75fy*As
fu = 8696156.6 N
fu = 8696.156579 kN

Taking Factor of Safety (FoS) = 2


fall = fu/FoS
fall = 4348.1 kN
Based on the structural capacity above, the micropile is able to take the given working load
of 4348.1 kN

Micropile Details

Micropile, Dia 400 mm

R6 Spiral Link

Rebar 4Y12

12/04/2020
Design of Micropile GEOPROFOUND ENGINEERING SDN BHD (707134-T)

Cement grout, G 35 N
W/C Ratio 0.45 min

12/04/2020
Design of Micropile GEOPROFOUND ENGINEERING SDN BHD (707134-T)

12/04/2020

You might also like