SITE SURVEY DESCRIPTION
OBJECT
This document is used during the site surveys phases and will be done and documented prior to any path surveys.
You need to pay close attention to details so we can collect information that would normally be gathered by those surveys.
Thanks to pay close attention to the responsability matrix and to adapt it to your Contract / Project
CUSTOMER INFORMATION
Service category : …
Job # : SURVEY…
Purchase order # : …
Subcontractor name : OMNIACOM
Field Technician name : KONE Maboualy
Service report author : …
Service report reviewed by : …
Service report approved by : …
Preferred start date : Preferred end date : …/ …/ …
pdates
battoirNew
loaAbattoirNew
98 56
SITE SURVEY REPORT
X
SITE SURVEY REPORT
PREREQUISITE
TOOLS
Responsibility
NOKIA/
Customer
subco
DOCUMENTS
Responsibility
NOKIA Customer
to use: speedtest.net in browser or ookla speedtest app from Google Play/Apple Store for mobile device. Responsibility
NOKIA Customer
SITE ACCESS
Responsibility
NOKIA Customer
Ladder ✘ Yes No X
Caged of ladder ✘ Yes No X
Cable Yes ✘ No X
Safety rail ✘ Yes No X
Type X
Safety equipment to be installed X
Health & Safety issues X
Comments
MATERIAL LIFTING
Responsibility
NOKIA Customer
INDOOR INFORMATION
Responsibility
NOKIA Customer
Comments
NOUVELLE LIAISON A REALISER
GROUNDING
Responsibility
NOKIA Customer
RACK
Responsibility
NOKIA Customer
INDOOR UNIT
Responsibility
NOKIA Customer
BREAKERS / FUSES
Responsibility
NOKIA Customer
Comments
DISPONIBILITE POUR INSTALLATION D' UNE NOUVELLE LIAISON
PRESSURIZATION
Responsibility
NOKIA Customer
Connections Detail
Source Destination Type # Connections Connector T Lenght (M) Label
NA NA 2 NA
Comments
AUXILIARY
Responsibility
NOKIA Customer
LABELING
Responsibility
NOKIA Customer
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
NIBILITE POUR INSTALLATION D' UNE NOUVELLE LIAISON
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
Responsibility
Customer
SITE SURVEY REPORT
TOWER / STRUCTURE
Responsibility
NOKIA Customer
PYLONE AUTOSTABLE
OUTDOOR INFORMATION
Responsibility
NOKIA Customer
sibility
Customer
HAUTEU
SITE SURVEY REPORT
Responsibility
NOKIA Customer
Space in the Tower for the ant support ✘ Available To be provided N/A X
Antenna support ✘ Available To be provided N/A X
Type of antenna support SUPPORT DISPONIBLE SUR MEMBRURE C X
Size of antenna support Unit ( e.g. mm ) X
Structure for antenna support mounting ✘ Available To be provided N/A X
Type of Structure for antenna support ✘ Corner Tubular Other X
Size of structure profile for ant support 84 Unit ( e.g. meter ) X
Comments SUPPORT DISPONIBLE SUR MEMBRURE C A 35M
SWAY BAR
Responsibility
NOKIA Customer
ODU
Responsibility
NOKIA Customer
Quantity of ODU 1
Type of ODU A DEFINIR
Structure for ODU mounting Available ✘ To be provided N/A X
Type of Structure for ODU mounting ✘ Corner Tubular Other X
Size of structure profile for ODU N/A… … Unit ( e.g. meter ) X
Comments
LES CARACTERISTIQUES ODU SONT SELON LES ORIENTATIONS DU BILAN DE
LIAISON
LE TYPE DE CABLE IDU-ODU EST FONCTION DES ODU NECESSITE PAR LE BILAN DE
LIAISON
(4) Ground
of the Building
(1)(2)(3) Example
of grounding plate
Responsibility
NOKIA Customer
Comments
sibility
Customer
sibility
Customer
sibility
Customer
sibility
Customer
N DE
sibility
Customer
LAN DE
sibility
Customer
SITE SURVEY REPORT
VISIBILITY ✘
Responsibility
NOKIA Customer
TYPE OF OBSTACLE
Responsibility
NOKIA Customer
Building Yes ✘ No X
Chimney Yes ✘ No X
Airport Yes ✘ No X
High voltage electricity tower and cable Yes ✘ No X
Tree Yes ✘ No X
Other Yes ✘ No … X
Comments Aucun Obstacle
SITE SURVEY REPORT
OUTDOOR LAYER
✘ Yes
L 1 2 3 4 5
W
6
7
OUTDOOR LAYER
✘ Yes
L 1 2 3 4 5
W
5
6
7
SITE SURVEY REPORT
DIGITAL PHOTO RECORDS – Exterior and Interior (Check List of Photos Recorded / Available)
SITE ACCESS
Site gate access view ✘
View if there is a storage place Storage under shelter Storage safety Space for storage ✘
GROUNDING
Main ground plate view ✘
RACK
Rack or a new subrack position view Available space to install new rack
INDOOR UNIT
IDU postion view Available space to install new shelf ✘
IF PRESSURIZATION
Dehydrator position view Dehydrator status ( If Existing ) Type of dehydrator
AC / DC power supply view
manifold, gauge air access view available
If existing Waveguide connection view
DIGITAL DISTRIBUTION FRAME
Internal DDF position view in the equipment rack with the type of interface ✘
External DDF rack / DDF position view with the type of interface ✘
Platform/Rooftop view
OUTDOOR INFORMATION
Feed-through entry - Outdoor view ✘
View of the place available in the Cable tray (Place for new cable) ✘
SWAY BAR
Sway bar mounting to the structure
ODU
ODU pole mounting view ✘
Level 2 ( Intermediate)
Grounding for IDU - ODU cable ✘