Z

1.0) Pile Load Distribution G9

Stump Enlargement -x = -0.25 m


Allowable Pile Working Load = 800 kN Stump Enlargement -z = 0m

Axial Working Load (Py) = 2150 kN Stump Coordinates (after enlarging)


ex= Σ(x1a1+x2a2...)/(Σ(a1+a2...) = 0.0000 m wx = -0.125 -0.125 m
ez = Σ(z1a1+z2a2...)/(Σ(a1+a2...) = 0.0100 m wz = 0 0m
Transv Moment (Mx=Py*ez) = -21.50 kNm
Long'l Moment (Mz=Py*ex) = 0.00 kNm

Pile Dia/ Location from cg Qy Qx Qz Q


Area Io ex ez x' z' ai xi ai zi Ix Iz
Ref Size x(m) z(m) (kN) (kN) (kN) (kN)
1 0.30 0.0900 0.00068 -0.145 0.03 0 0.6 -0.020 0.630 -0.002 0.057 0.035 0.001 716.67 -22.066 0.000 694.601
2 0.30 0.0900 0.00068 -0.18 -0.05 -0.45 -0.3 -0.505 -0.350 -0.045 -0.032 0.012 0.024 716.67 12.812 0.000 729.479
3 0.30 0.0900 0.00068 -0.05 0.05 0.45 -0.3 0.525 -0.250 0.047 -0.023 0.007 0.025 716.67 9.253 0.000 725.920
ΣΑ = 0.2700 0.000 0.003 ΣQ = 2150.000

Ix = Σ(Ιi+Αidzi2) = 0.054 Max Q(+) = 729.479 kN; 'Safe'


Max Q(-) = ----
Iz = Σ(Ιi+Αidxi2) = 0.050 0.91