SHIP: INS KORA

EQUIPMENT : GEAR BOX at STARBOARD SIDE

Vibration Velocity (rms) mm/sec.


Measuring Location
Horizontal Vertical Axial
MAIN ENGINE 6.6 6.9 2.7
EFE
ED 4.9 3.6 1.7
E

Measuring results on each gears location

Velocity (rms) mm/sec- Vertical directions

Location at each gear Horizontal Vertical Axial


Gear 1 0.6 4.4 5.3
Gear 2 1.7 1.4
Gear 3 4.0 5.3 4.6
Gear 4 4.8 5.5 3.5

Measuring results on gear box location

Velocity (rms) mm/sec- Vertical directions

Location over all points Horizontal Vertical Axial


at gear box
Gear box GBDE 0.6 4.6
GBFE 5.3 6.6 0.3

Diagnosis:

Fire pump vibration readings and spectrums symptoms indicate soft foot, looseness and
misalignment, gear tooth damage inaccuracies.

Recommendation action plan:

 Time wave form and FFT Spectrum indicates clear repetitive impacts on gear teeth
damage inauuracies. Please inspect the gear teeth condition if required changed with new
one.

 Inspect the coupling alignment between motor to pump for any inaccuracies.
 Inspect the coupling bolts bushes condition for any inaccuracies.
 Inspect seating of motor soft foot to top of the mounts.