Corrective Action: Internal Use Only
Corrective Action: Internal Use Only
Contents:
1. Summary
We received a few complaints that the power does not go on because of a failure
in the power supply unit. As a result of investigating the problem, we found a short
circuit on the power board that was caused by foreign objects entering the power
supply unit.
Please apply dustproof measures to the power supply unit.
2. Requirements
Lid A (Changed shaped) Part No. 0790B4002A00
Packing (New) Part No. 079014014A00
Contact the CS Group at the Konica Minolta MG QA Center regarding the supply
of equipment.
3. Procedure
Refer to the attached instruction sheets.
5. Working Time
1.0 H
Submitted by M.Oguri
Approved by M.Sato
1/3
Internal use only
3. Remove the 13 screws and then remove Lid A and B from the power supply unit.
Lid B
Lid A
4. Attach a packing (079014014A00) around the air inlet on the rear side of the power
supply unit.
2/3
Internal use only
New Lid A
6. Clean the power supply unit and make sure there is no dust or foreign object.
7. Re-attach Lid B.
8. Attach the power unit to the main unit in the opposite sequence to removal.
The lower right side panel must be attached before turning the power ON. Dust
will be sucked in the power supply unit easily if the power is turned ON without
the attachment of the lower right side panel (as there is no filter).