Average illumination is not less than 160 lux; edge

R108 F contrast ratio is minimum 4:1. Field size at the different


Focus Film Distance (FFD - SID) settings is shown on
SQUARE-FIELD SINEGLE- OR, OPTIONALLY, MULTI-LAYER the front panel.
X-RAY COLLIMATOR; LIGHTWEIGHT AND COMPACT,
IDEALLY SUITED FOR INSTALLATION ON MOBILE OR FIXED
TECHNICAL FEATURES:
X-RAY EQUIPMENT. MOUNTING PLANE AT 80 MM (3.14") - External adjustment of mirror angulation.
FROM THE FOCUS. - High luminosity provided by a white power led.
R 108 F - Timer limiting projection lamp exposure time to 30 seconds
In the standard single- layer version, the x-ray field is
defined by two pairs of shutters and a cone at the x- thus extending lamp life by preventing overheating.
ray beam window. - Radiation shielding: 125 kVp - 4mA, on request 150 kVP -
4 mA.
In the version mounting RO 334, he x-ray field is - Minimum inherent filtration 2 mm aluminium equivalent
defined by six pairs of shutters, two of which are lead- (1mm on request)
lined. The six pairs of shutters move perpendicularly - Continuous film coverage from min. 00 x 00 cm to max. 43
within the x-ray field. Four pairs of shutters are in x 43 cm at 100cm FFD (SID).
bronze: two are located near the focus and two are
located near the entrance window. Two leaded OPTIONAL ITEMS:
shutters are located near the exit window of the x-ray RO 240 - Focus-skin spacer
beam from the collimator and serve to accurately RO 242 – Laser line for collimator/image receptor alignment,
define the x-ray field edges. RO 250 - Radiation shielding up to 150 KVp - 4 mA
Shutter movements are manual and controlled by two RO253 – Spacer guides, plastic for DAP assembly.
knobs on the collimator front panel. RO 313 - Customized front panel
The square-field X-ray beam Limiting Device is RO 319 - Additional variable filtration with manual selection on
designed for installation on rotating or fixed anode X- Aluminium disc, 1mm thickness::
1mm Al equivalent + 0,1 Cu
ray tubes (mounting RO 334) (EN 60601-1-3 par
R108 F + RO 319 + RO 334 1mm Al equivalent + 0,2 Cu
29.202.3); manual controls provide for the adjustment
2mm Al equivalent
of the X-ray field dimension to the size of the image RO 334 - 4 pairs of bronze shutters: 2 located near the focus
receptor or to that of the anatomical area of interest. and 2 in the collimator x-ray window.
Adjustment to the area under investigation is possible RO 335 - Mounting plane at 100 mm instead of 80 mm. This
by using the knobs on the front panel. version cannot mount RO 319 (additional filters) and
Direct visualisation of the x-ray field is provided by a RO 334 (near port shutters).
light beam which corresponds to the x-ray beam,
within a tolerance of two percent of the selected FFD
(SID) value. The light-field centre is provided by the
intersection of two perpendicular lines silk-screened
into the Lexan window and projected on the light field
by the light beam.
Ralco s.r.l.
RALCO SRL
To activate the light field, press the area marked with the VIA DEI TIGLI 13/G
light symbol on the front of the device. The light will 20046 BIASSONO ITALIA
switch on for 30 seconds and an electronic timer will TEL. +39 0392497925
switch the lamp OFF automatically. Dim. in mm FAX. +39 0392497799
www.ralco.it email: ralco@ralco.it
4.5 kg
Ralco reserves the right to make changes in specifications and/or to discontinue any product at any time without prior notice or obligation and will not be liable for any consequences resulting from the use of this publication. Any technical data contained in this document may vary. Original images always lose a certain amount of detail when reproduced.