The present document describes how to commission ANDREW RET units in Single_RET
antenna type, and DAISY_CHAIN connection scenario using eNodeB LMT.
1. MOD RETPORT
--- END
2. SCN ALD
SCAN ALD
--------
Control
port Control
Control port subrack port slot Control ALD device Vendo Protocol Configur
cabinet No. No. No. port No. Result type r code Serial No. version e status
(Number of results = 3)
We can see that eNodeB detects the new RET units, however they are not configured.
3. ADD RET
Now add the RET units, ADD RET. Use the serial numbers provided by SCN ALD
command for each RET.
2020-12-07 Huawei Proprietary - Restricted Distribution Page2, Total6
ANDREW RET Commissioning Security Level
Internal
--- END
--- END
4. CLB RET
Calibrate RET
-------------
Device No. Subunit No. Result
0 1 SUCCESS
(Number of results = 1)
--- END
Calibrate RET
-------------
Device No. Subunit No. Result
1 1 SUCCESS
(Number of results = 1)
--- END
5. DSP RETSUBUNIT
0 1 AVAILABLE 72 NULL
1 1 AVAILABLE 100 NULL
(Number of results = 2)
--- END
6. MOD RETTILT
Modify the current tilts, and verify the changes by command and physically on RET. Use
MOD RETTILT command.
--- END
--- END
Display the current electrical tilt, DSP RETSUBUNIT. It should now show the modified
values.
--- END
7. LST RETDEVICEDATA