Professional Documents
Culture Documents
MRV Os906g-Me PDF
MRV Os906g-Me PDF
Product Highlights
Carrier Ethernet service demarcation
- MEF-compliant CE2.0 services
- MEF 9, MEF14, and MEF 21 compliance
Unified Master-OSTM control plane for all models
2.5Gbps rate for high-speed service offerings
- Enables service providers to offer higher speed
services without the cost of a 10GE port
(**)
Carrier-grade resiliency - sub 50ms recovery time
- ELPS G.8031 and ERPS G.8032
OS906G Series Hierarchical QoS for premium SLAs
End-to-end Service OAM to monitor SLAs
The OptiSwitch® 906G series is a complete product line that comprises MEF-compliant L1 Shaping
CE2.0 carrier-class intelligent Ethernet Demarcation service devices. MPLS LER & LSR functionality
The OS906G portfolio includes 1/2 19” devices, full 19” devices with dual redundant Full range of L2 and L3/IP Services
and pluggable power supplies, temperature hardened models, and timing & - L2 Carrier Ethernet, MPLS, MPLS-TP (*)
synchronization supporting models. and IPv4/IPV6 (*) Forwarding & Routing
The OptiSwitch® 906G series was perfectly designed to converge premium L2 and L3 sFlow support for Application-Aware Networking
services into single cost effective and yet scalable unified devices. SyncE and IEEE1588v2 PTP Timing & Synchronization
The OS906G series enables premium manageable end-to-end Ethernet services Zero-touch provisioning with rapid service turn-up
with extensive traffic management, performance management, and HW-based OAM and customer web portal
tools ensuring strict Service Level Agreements (SLAs) across optical packet switched - MRV’s Pro-Vision Service Provisioning and NMS
networks. Temperature hardened models
The OptiSwitch® 906G provides Ethernet demarcation functionality for SLA-based Applications
business Ethernet services, Ethernet mobile backhaul, including Synchronous Business Ethernet Services
Ethernet and IEEE1588v2 PTP Timing & Synchronization support, and External Mobile Backhaul Services
Ethernet Network-to-Network interfaces with end-to-end Ethernet services across Carrier Ethernet enabled Cloud Services
multiple service providers. Inter-operator E-NNI Services
LAN WAN
4G/eNodeB
OS-906G
L I A L I A L I A L I A L I A BITS
PS2 FAN
L L S1
PS1 PWR
A A S2
RNC/S-GW
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2 5 6
OS-906G
L I A L I A L I A L I A L I A BITS
PS2 FAN
L L S1
PS1 PWR
A A S2
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2 5 6
!
2
1
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
EM9005 PS/AC
18
17
20
19
22
21
24
23
24
23 22
21
24
23
L
A
25
10GE-XFP
CONSOLE EIA-232
L
A
26
MGT ETH
10GE-XFP
PS2
L
A
27
10GE-XFP
RST
OptiSwitch
9124-410G
L
A
28
10GE-XFP
Optical Packet
Switched Network
EM9005 PS/DC
ADD EXP
47 49 51 53 55 57 59 61 IN OUT
PS1 PWR
A A S2
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2 5 6
OS-906G
L I A L I A L I A L I A L I A BITS
PS2 FAN
L L S1
PS1 PWR
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2
A
5
A
6
S2 OS-906G
PS2
L I A L I A L I A L I A L I A BITS
3G
PS2 FAN
L L S1
CONSOLE EIA-232
PS1
TMP FAN OptiSwitch OS940
PS1 PWR
USB HOST L L L L CONSOLE EIA-232 MGT ETH A A S2
1 2 3 4 1 2 5 6
A A A A
13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 10GE-XFP 10GE-XFP 10GE-XFP 10GE-XFP
Node B
End - to - end Service OAM
End - to - end Service OAM
Carrier Ethernet Demarcation - UNI Mobile Backhaul (NGN Packet Switched Network)
- Bandwith on demand
- SLA & Performance Monitoring
Cloud Services
Operator 1 E -NNI Operator 2
OS-906G
L I A L I A L I A L I A L I A BITS
PS2 FAN
L L S1
PS1 PWR
A A S2
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2 5 6
For inter-provider connecting points, the OS906G serves as a demarcation device at carrier-to-carrier on-net locations and provides External
Ethernet Network-to-Network interfaces (E-NNI) that separate two different service provider networks. In such a deployment scenario, the
OS906G enables Ethernet service delivery over multiple carrier transport networks with end-to-end visibility and control.
The OS906G series includes 4 basic models (noted in the ordering information section on the last page):
1. ½ 19” 1U device with internal AC/DC power supply and optional redundant and external AC/DC power supply
2. Full 19” 1U device with dual pluggable & redundant AC or DC power supplies
3. Temperature-hardened (-40ºC to 65ºC) full 19” 1U device with dual pluggable & redundant AC or DC power supplies (future HW option)
4. Temperature-hardened (-40ºC to 65ºC), SyncE and IEEE1588v2 (Master *, Slave, BC) supporting devices. Full 19” 1U with dual pluggable &
redundant AC/DC power supply.
(*) Future Software release
(**) For selected models
Not sure which solution best meets your needs? Visit www.mrv.com or e-mail us at sales@mrv.com
VPN Services & Protection
Compliant to MEF Ethernet Virtual Circuit (EVC), the OS906G offers the following 3 types of VPN service:
1. Layer 1 Optical VPN – a cross-connect mode without MAC address learning
2. Layer 2 VPN – VLAN-based tunneling, Q-in-Q stacking, swapping, or mapping services
3. Layer 2.5 VPN – a label-based MPLS VC for direct connection into MPLS domains or H-VPLS MTU-s
All the above VPN services can be fully protected using port redundancy, dual-homing, and/or ring topology with a recovery time less than 50 ms.
In addition to L2 VPN, the OS900 offers integrated IP router services to save on cost of an external router, and provides a single
demarcation platform for managed L2 VPN and IP services.
End-to-end OAM - IEEE802.1ag , ITU-T Y.1731, IP-SLA & RFC2544, ITU-T Y.1564 Service turn-up (*)
The OS906G series incorporates connectivity, discovery, and fault management along with performance statistics of delay, jitter, and frame
loss for demarcation and intermediate points of service. OS906G series offers hardware-based SLA measurment tools with nanosecond
accuracy.
The OS906G demarcation series is a standard-compliant and interoperable OAM solution that enables:
1. End-to-end Connectivity Fault Management per IEEE802.1ag
2. End-to-end Performance Measurement per ITU Y.1731
3. IP SLA with HW-based time stamping (IP-VPN measurements)
4. RFC2544 Layer 2 and 3 testing at up to 1Gbps rate
5. MEF SOAM per MEF10.2
6. Y.1563 Service Availability Measurement based on SLM/SLR
7. Y.1564 service turn-up (*)
troP lla
troP lla
troP lla
troP lla
eliT
pleH
ylpitluM
1
1
1
1
1
1
1
1
1
1
1
1
)elbapac NALVSI( tiBagiG : epyT
edoMitluM-scitpOrebiF
pU si kniL
ffO si eerTpS
delbanE
delbasiD
xelpud _lluF
agiGecrof
edoM NALVSI
6378016411
5909708
65694
59844
0
0
0
0
0
0
0
0
: epyT lacisyhP
sutatS kniL
eerT gninnapS
etatS troP
lortnoC wolF
edoM xelpuD
deepS troP
edoM NALVSI
eerT gninnapS
lecnaC
32
3
3
gnitnuoccA
txeN
setyB tupnI
stekcaP tsacinU tupnI
stekcaP tsacinU-noN tupnI
stekcaP dedracsiD tupnI
stekcaP rorrE tupnI
stekcaP locotorP nwonknU tupnI
setyB tuptuO
stekcaP tsacinU tuptuO
stekcaP tsacinU-noN tuptuO
stekcaP dedracsiD tuptuO
stekcaP rorrE tuptuO
)stekcap( htgneL eueuQ tuptuO
teseR
tmgM rrEtmX XR XT
kniL cF xR
rebmuN troP
stnC stroP
rebmuN tolS
verP
shparG scitsitatS
scitsitatS NOMR
KO
32
32
32
32
32
32
32
32
32
32
32
32
SMN
SMN
sailA
SMN
SMN
SNMP
Automated Control
L I A L I A L I A L I A L I A BITS
PS2 FAN
L L S1
PS1 PWR
A A S2
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2 5 6
based on the customers view. Pro-Vision supports standard based PS2 FAN
PS1 PWR
CONSOLE EIA-232
L I
MGT ETH
A L I
1
A L I
2
A L I
3
A L I
4
A
1 2
L
A
5
L
A
6
OS-906G
S1
S2
BITS
PS1 PWR
A A S2
CONSOLE EIA-232 MGT ETH 1 2 3 4 1 2 5 6
PS2
CONSOLE EIA-232
PS1
TMP FAN OptiSwitch OS940
USB HOST L L L L
A A A A
13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 10GE-XFP 10GE-XFP 10GE-XFP 10GE-XFP
Packet Ring and Link Protection Services Management & Diagnostics Tools
• ERPS per ITU-T G.8032v2/Y.1344 • Out-of-band management via EIA-232 console port
• ELPS per ITU-T G.8031 • Out-of-band Ethernet management port
• MSTP per IEEE 802.1s • Industry Standard CLI
• Sub 50 ms network recovery for ring and dual–homed • Link Layer Discovery Protocol (LLDP) per IEEE802.1ab
topologies • Hierarchical Administration policy
• Link Aggregation (LAG n+1) – static and LACP • TELNET, SSHv2, SNMPv3, RMON (4 groups)
- Load balancing based on L2-3-4 headers • Port mirroring - ingress & egress traffic to analyzer port
• Link level 1:1 Loss of Signal (LOS) protection • RADIUS and TACACS+ AAA
• Hardware-based OAM CFM messages for fault detection and • Configuration load/save with FTP or Secure Copy (SCP)
link fallback • Network Time Protocol (NTPv3)
• Bi-directional Link Fault Reflection • Internal / Remote Syslog
• IPv6 management
Multicast and IP Services • Supported by MRV’s ProVision Service Provisioning and NMS
• Wire-speed multicast replication
• IGMP v1,v2 snooping , proxy, and fast leave, PIM-SM, PIM-SSM Standard-based OAM
• Wire-speed IPv4 and IPv6 packet fowarding and routing • EFM Link OAM per IEEE802.3ah
- RIP, RIPng, OSPFv2, OSPFv3 , BGP4, BGP4+, VRRP - discovery, port-loopback, and dying gasp
- BFD • End-to-end Service OAM per IEEE802.1ag
- DHCP server/client/relay - Connectivity Fault Management per service MEP/MIP
- In-service EVC loopbacks, linktrace and continuity check
Layer 2.5 Services • End-to-end Performance Measurement ITU-T Y.1731
• MPLS LER & LSR functionality • MEF SOAM PM (MEF 35)
Ethernet over MPLS pseudowire with Traffic Engineering • End-to-end IP SLA measurement
• MPLS Protection based on FRR detour mode and dual-homed
spoke MTU-s - Jitter, Latency and Loss per service with ns accuracy
• MPLS BFD for MPLS OAM (based on RFC 5884) • RFC2544 internal tester for wire-speed throughput
• MPLS OAM (MPLS PING / MPLS Traceroute) measurement
• Y.1563 MEF 10.2 service availability and resilency
High Availability measurement
• Pluggable 1:1 Hot-swappable dual redundant power • Y.1564 service turn-up (*)
- AC and/or DC (for OS906G-M models) • Optical signal level monitoring (SFP SFF-8472)
• Ambient temperature sensor for alerting • Copper cable diagnostics (TDR) on RJ45 ETH ports
• Dual image and rollback processes • Integrated 3rd party OAM probes for end-to-end proactive
• Modular control plane - Master-OS™ speech and video quality & performance measurement to
assure strict SLAs to the service provider’s customers
Traffic Management
• Traffic management per flow/EVC/Port Timing & Synchronization Services
• Shaping and policing at L1/L2/L3 (for OS906G-M/MBH and OS906G-M/MBH/E)
• Ingress and egress policing and shaping • ITU-T G.8261, G.8262, G.8264 , ITU -T G.703
• Color aware and color unaware BW-profile per MEF 10.2 • ITU-T G.736, G742, G.813, G.823, G.824
• Congestion avoidance mechanisms: Tail-Drop and Weighted • IEEE1588v2 PTP– Telecom Profile
• IEEE1588v2 PTP Master */Slave/BC modes
(*) Future Software release
Technical Specifications
OS906G OS906G-M
Regulatory compliance FCC Part 15 (class A); EMC Directive (class A emission, immunity); Low Voltage Directive (electrical safety);
RoHS Directive; WEEE Directive; CE; TUV-R (USA, Canada); GOST (for selective products); REACH SVHC;
ETSI (for selective products); NEBS Level 3 Certified (OS906G-M/E and OS906G-M-MBH/E),
C-Tick (for selective products).
Temperature Range Operating Temp: 0oC to 50oC (32 to 122 oF) Storage Temp: -40oC to +70 oC (-40 to 158 oF)
Extended Temperature Range NA -40oC to +65 oC (-40 to 149 oF):
applicable for OS906G-M/E and OS906G-M-MBH/E
Humidity (max.) 85% (non-condensing)
Physical dimensions 219.6 x 265 x 43.65mm3 444.0 x 230 x 43.65mm3
WxDxH (8.64 x 10.43 x 1.72 inch3) (17.3 x 9.05 x 1.72 inch3)
Weight 1.05 kg (2.31 lb) 1.7 kg (3.74 lb) - without PS
2.45 kg (5.39 lb) - with PS
MTBF OS906G-AC 148410 hr @ 25 oC 597850 hr @ 25 oC (OS906G-M/E)
OS906G-DC 485496 hr @ 25 oC 525456 hr @ 25 oC (OS906G-M)
437168 hr @ 25 oC (OS906G-M-MBH/E)
Max. Power Consumption 23W 30W
Power Feeding AC Input Voltage Line (frequency 50 to 60Hz):
100 to 240 Vac
DC Input Voltage:
18 to 60 Vdc
Optional desktop power supply 5V, 8A, 40W NA
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the
accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information.
MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.