SADDLESMAYBE USEDIN NEWCONSTRUCTION

ONLYWITHTHE APPROVAL or THE PWCSAAND


SHALLBE SUBJECTEDTO TEN FEETor
HEAD(4,3 PSI) PRIORTO
HYDROSTATIC
CUTTINGMAIN.

LOOPTRACERWIRE
AROUNDMAIN
s SANITARY
MAIN
SEWER

FLOW

PREMANUFACTURED TEE_/ 90" UNLESSOTHERWISE


SHOWNON PLANS

. ....._
___ ___ STANDARDf57 STONE
SEWERSERVICECONNECTION BEDDING
THROUGHOUT
PERSPECIFICATIONS

d.....Ll )_ ____ .__ TIE WRAPTRACERWIRE


EVERYS'

MIN. 20' (1 FULLJOINT)


BEYONDPROPERTY LINE

2' or WIRE
LOOPADDITIONAL
J_
PASTENDor LATERALFOR
CONNECTION
TO PLUMBERS
C900 x IPS COUPLING
or LATERAL----­
PORTION with IPS PLUG

SEWER SERVICE CONNECTION


PLAN VIEW FOR NON- PUBLIC
SO1.07.01
RIGHT-OF-WAY
N,T,s, REV-2017
z
~
ci en
zz
o5
- IL
!c
.... z
en o

PREMANUfACTURED
TEE
s SANITARY
MAIN
SEWER

90- UNLESSOTHERWISE
SHOWNON PLANS

CUT EXISTINGSERVICELINE AND


PLUGEXISTING TEE AT MAIN
- - # 12 SOLIDCOPPERTRACER
WIRE(COATED)

._ ______ STANDARD#57 STONE


BEDDING
THROUGHOUT

PROPERTY
LINE----­

SEWER SERVICE CONNECTION


TERMINATION S01.11.01
N.T.S. REV-2017
----------

SADDLESMAYBE USEDIN NEWCONSTRUCTION


ONLYWITHTHE APPROVAL or THE PWCSAAND
SHALLBE SUBJECTEDTO TEN FEETor
HEAD{4.3 PSI) PRIORTO
HYDROSTATIC
CUTTINGMAIN.

LOOPTRACERWIRE

AROUNDMAIN

SEWER
SANITARY
MAIN

FLOW

90" UNLESSOTHERWISE
SHOWNON PLANS
PREMANUFACTUR£D
TEE_/

. ,_ ___ ___ STANDARDf57 STONE


SEWERSERVICECONNECTION BEDDING
THROUGHOUT
PERSPECIFICATIONS

<1-..LJ,- -__....___ TIE WRAPTRACERWIRE


EVERY5'

,.
PROPERTY
LINE CLEANOUT

MIN.20' {1 FULL JOINT)

BEYONDPROPERTY LINE NOTE:

1. FORELEVATIONS

LOOPADDITIONAL2' OF WIRE
J_
AND FURTHERDETAILS,

SEE DETAILS02.07.00 & SECTION170.05


OF THE USM.
PASTEND OF LATERALFOR
CONNECTION
TO PLUMBERS
C900 x IPS COUPLING
OF LATERAL
PORTION with IPS PLUG

SEWER SERVICE CONNECTION/REPLACEMENT

PLAN VIEW FOR PUBLIC

RIGHT-OF-WAY SO1.17.00
REV-2017
MARKENOOF
ALLLATERALSWITH
. 4" x 4" POST

OOPADOlllONAL
g 2' Of WIREPAST
LATERALFOR
a~~
I­ w
i3
~ CONNECTION
t-- PLUMBERS
TO
PORTION
PREMANUFACl\JRED en OF LATERAL
TEE

C900 X IPS COUPLING


with IPSPLUG

OFFSETSTAKE
en
<
g
w
MIN.3'
I­ !~
i3 en~
MIN.5'

# 12 SOLID COPPER ~ ~
ER WIRE(COATED) ~
TRAC

COMPACTED
BACKFILL
SELECTED
MATERIAL
I
PREMANUFACl\JRED
TEE

__J
PROPERTYLINEOR
RIGHTOF WAY I
FILL ALL VOIDSUNDERPIPE
WllH 157STONE

NOTES:
1. GRAVELBEDDING
THROUGHOUT
t,.S PERSECTION
170.01.b
2. RISERSLOCATED
DIRECTLY
OVERTHESANITARYSEWER MAINMUSTBE NOTED
ON
THEPi.ANS.
3. 4• LATERALS
MUSTHAVE
A MINIMUM GRADEOF2.08". 6" LATERALS
MUSTHAVEA MINIMUM
GRADEOF 1.00".
4. MARKALLENDSOF LATERAL
WITH4"x 4" WOODENPOST.

SEWER SERVICE CONNECTION


PROFILE VIEW FOR NON-PUBLIC
RIGHT-OF-WAY S02.07.00
REV-2017
OFFSETSTAKE MARKENDOF
PROPERTY
LINECLEANOU
ALLLATERALSWITH
4• x 4• POST

I 12 SOLIDCOPPER

~
lRACERWIRE(COATED)
TIE WRAPTRACER
Yt1REEVERY5'

INVERTELEVATION
AS SH0Yt111
ON PLANS

C9DOX IPS COUPLING


with IPS PLUG

L
OFFSETSTAKE\
PROPERTY
LINECLEANOU~ \
OfFSETSTAKE

~ ~~H~~~ _1
1'
""
MIN. 3'
I-!~
a en~ MIN. 5'
# 12 SOLID COPPER W3:
WIRE(COATED) ~
TRACER
0

COMPACTED
BACKALL

SELECTED

MATERIAL
I
PREMANUFAClURED ...__o--:...._TIE WRAPTRACER
TEE WIREEVERY5'

PROPERTYLINEOR
RIGHTOF WAY
_J · 1
ALL AU. VOIDSUNDERPIPE
Vt11H#57 STONE

NOTES:
1. GRAVELBEDDING ,s PERSECllON170.01.b
THROUGHOUT
2. RISERSLOCATED
DIRECTLY
OVER THE5Af4ITARY
SEWER MAINMUSTBE NOTED
ON
THEPLANS.
J. 4" LATERALS
MUSTHAVEA MINIMUMGRADE OF 2.0BX.6" LATERAIS
MUSTHAVEA MINIMUM
GRADEOF 1.00,t
4. MARKALLENOSOF LATERAL
WrTH4"x 4• WOODEN POST.

SERVICE CONNECTION/REPLACEMENT
PROFILE VIEW FOR PUBLIC
RIGHT-OF-WAY S02.17.00
REV-2017
3
.-1- -- ·--· I

·<1•
<I .

' <1 .d . ~

. . Ll : <1 ~ ••

:4 <I
. L1
<J. •

..:1
, <1

, 4<1
A .. 3'

<1
<1
• <1

. 4
4~ .' ..
41

<1 .

SIX RIBS, EQUALLY


SPACED

NOTE: :::~~-___...~TIE WRAPTRACERWIRE


EVERY5'
ALL PARTSSHALLBE
ASPHALTUMPAINTCOATED
~ 6" SANITARYCLEANOUT
ASTMA-48, CLASS25 # 12 SOLID COPPER
CASTIRON. SECTIONA-A TRACERWIRE {COATED)

CLEANOUTCOVER
FOR PAVEDAREAS S03.07.01
N.T.S. REV-2017
r 12" -i CLEAN OUT CAP
MUST BE BRASS

# 12 SOLID COPPERTRACERWIRE(COATED)

4" CLEAN-OUTSTACK

#57 STONE
PLUG

FLOW

4" GRAVITY LOW PRESSUREFORCEMAIN


LATERAL FROMGRINDERPUMP
SANITARYTEE

---- PROPERTYLINE OR

RIGHT-OF-WAY

NOTE:

GRAVITY LATERAL SHALL CONFORMTO SEWER

SERVICE CONNECTIONDETAIL EXCEPT FOR

LOCATION RELATIVE TO PROPERTYLINE.

. GRINDER PUMP CONNECTION TO


GRAVITY SEWER MAIN S04.07.01
N.T.S. REV-2017
NOTE:
THISMETHOD
OF CONNECTION
SHALL

NOTTAKE
PRECEDENT
OVERUSINGTEES.

THEAPPLICATION

SHOWNHEREIS FORTAPPING
EXISTING
MAINS.

PVCHUB

RUBBER
BOOT

NOTE:
INSERT-A-TEE CANBE CONNECTED TO PVC,
PERMALOC, SPIROLITE,
SLIPLINER,QUCTILEIRON,THIN
WALLMAINLINES,CONCRETE(MAINLINESAND
MANHOLES), CLAY,ALL THICKWALLEDMAINLINES.IT
IS A THREEPIECECONNECTION THATIS
COMPRESSION-FITINTOTHECORED WALLOF THEMAIN
LINE.IT CONSISTS
OF SIDESERVICES OF 4" THROUGH
12" ANDFITSALL MAINLINEDIAMETERS.

INSERT-A-TEE
N.T.S. S05.07.01
REV- 2017
NOTES:
1. MANHOLE TO MEETCURRENT REQUIREMENTS OF ASTMSPEC.C--478.
2. AU REINFORCING STEELTO MEETCURRENT REQUIREMENTSOF ASTMSPEC.A-615.
3. CONCRETE TO BE -4000PSI MINIMUMCOMPRESSIVE STRENGTH.
-4. TAPERED JOINTWITH0-RING GASKETTO MEETCURRENT REQUIREMENTS OF ASTM
SPEC.C-361 & C-«3.
5. 301 MASTICOR APPROVED EQUALSHALLBE USEDIN ADDITION TO THE JOINTSPECtf'IED.
6. APPROVED FLEXIBLEJOINTREQUIRED ON AU PIPECONNECTIONS TO MANHOLES.
INSTALLATION SHAU BE IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS.
STUBMAYBE USEDAT THE APPROVAL OF THE INSPECTOR.
7. MANUFACTURER'S NAMETO BE ON THE INSIDEFACEOF ALL SECTIONS.
8. SETCOVERFRAMEON PIONEER 301 MASTICOR APPROVED SUBSTITUTE.
9. FASTENWATERTIGHT FRAMETO 3/-4• ANCHORBOLTS(SETACCORDING TO CONESECTION
DETAIL)WITHNUTAND 2• WASHER.CUTANCHORBOLTSOFF 1• ABOVENUT.
10. KEYWAYS MAYBE SUBSTITUTED FORLIFTINGLUGS.
11. SHOPDRAWINGS AREREQUIRED
FORMANHOLES USEDWITHSEWERMAINSGREATER THAN
2-4" AND MUSTBE APPROVED BY PWCSA.
12. MASONRY UNITSMAYNOT BE USEDFORADJUSTMENTS.
13. MANHOLE STEPSSHALLBE AMERICAN STEPCOMPANY ML-10-TDS-SSR ORAPPROVED SUBSTITUTE.

SEEMANHOLE COVER

RINGDETAIL

PRORINGORLADTECHADJUSTING
RINGSOROTHERSAPPROVED
BY SERVICE
AUTHORITY CONE

OPTIONAL
FIBERGLASS
SEEPRECAST
CONCRETE INSERT
SEAL
CONESECTION
DETAIL STEPSTO BESETINLINE

RISERS1,0' MIN; 5.0' MAX.

BITUMASTIC
COATING
0 LUG
LIFTING
RISER
NOTCHFOR0-RINGGASKET

LUC,NOTHROUGH _:J
LIFTING
HOLESAUOWED ~
.., '.
I,

. , ...
en
.....
,,
,
.
ii: BASE
~ ··,

'' .
~
..
...;_: ·-~·:., .
i------
,. ..
I
MIN. s• COMPACTED--1.or
!Pllllo:-t---4 ,4·-0·
---- - -
VDOTNO. 57 STONE

- -- --- s·-s· MIN.-------------1

PRECAST CONCRETE
4' DIAMETER MANHOLE S06.07.01
N.T.S. REV-2017
"'-..STANDARD
MANHOLE
rRAME& COVER
PRO RINGOR LADTECHADJUSTING
\ '
RINGSOR OTHERSAPPROVED 6....::
- - =---i:3
NOTES: SY SERVICEAUTHORITY di _ _ b
1. CONCRETE
STRENGTH,
MUSTSE 4000 PSI COMPRESSIVE
MINIMUM. ...,
._;,-.;!,...
.... J ---­ r.­.....
... . ..!
2. PIPECONNECTIONS TO MANHOLESTO SE APPROVED
rLEXISLESLEEVES.
3. MANHOLES OVER6' DIAMETER REQUIRE
DETAILEDDRAWING ON PLANS
••
4. ALL REINrORCING MUSTMEETCURRENT
REQUIREMENTS or ASTMSPEC.A-615.
5. MANUrACTURER'S NAMEMUSTBE ON INSIDE
rACE or ALL SECTIONS.
6. MANHOLE MUSTMEETCURRENT REQUIREMENTS
or ASTM.SPEC.C-478.
7. PLACE5• COMPACTED VDOTNO, 57 STONE
UNDERBASESECTIONS.
8. JOINTCONrlGURATION MAYSE CASTBELL-UP
OR SPIGOT-UP.
9. MANHOLE STEPSTO BE AMERICAN STEPCOMPANY
ML-10-TDS-SSR OR APPROVED SUBSTITUTE.

0-RING JOINT
ASTMC-361
ASTMC-«3 4

tr . . . ·., '·"'. .,
~ ·i
. . . ~
.
·. •: '. STD. PRECASTCONC
.
··~­.,;
.. ~ rLAT TOP REDUCER

A
MANHOLE

5'
60'"
DIAMETER
IN rEET
6'
72"
t
G
'

:­~­
..__
.

: :..~. . LIFTINGLUG
.. KEYWAY(TYP.)

;'i·:"­
or_/
-0­

In
B
:z C
e.-·
5•
gs•
7•
STD. PRECAST
CONC.RISER

0
i!
w
D 8'" 8" .. ~- ;
., .• .
:I E VARIES •• ~ I
i5
r 13'" MIN. 13'" MIN.
G VARIES

PRECAST CONCRETE
5' AND 6' DIAMETER MANHOLE S07.07.01
N.T.S.
REV-2017
NOTES:

1. CONTRACTORMUSTHAVEADEQUATE EQUIPMENT
TO PUMPAROUNDEXISTING

LINEWHILEMANHOLEIS CUTIN.

2. PRECAST
CONCRETE
MANHOLE
SHALLCONFORM
IN ALL OTHERRESPECTS
TO
STANDARD
PRECAST
CONCRETE
MANHOLES.
3. DOGHOUSEMANHOLES
ARENOTPERMITTED
WITHOUT
WRITTEN
PERMISSION
FROMTHE PWCSA.

OPTIONAL
FIBERGLASS
INSERTSEAL

....._______. .
, ..
. . .,
,·· .
··,. .

•...,-~.

. 41

A
KOR-N-SEAL
4' MIN. -l
4 ' OR
CAST-IN-PLACEBOOT (TYP.) I

• 4 •

•? 4 ·. 41
. .,d

• • 41 4 .· 41• ••
•41

WATERTIGHTCOUPLING
OR SLEEVE(TYP.)

'--­ EXISTING
LINE(TYP.)

PRECASTCONCRETE
CUT-IN MANHOLE S08.07.01
N.T.S. REV-2017
SlD. MANHOLE
FRAME,t COVER b PRORINGOR LAOTEOiAOJJS11NGRINGS
c5f_-_~ OR OTHERS BY SERVICE
APPRQ'-t(I) AUTHORllY

NOlES:

1, PRECAST MANHOLE SECTIONS SHAl.1.CONFORM TO


PWCSAUTIUlY STANDARDS MANUAL
2. BASESECTION DIAMETER SHAl.1.BE:
~. 4'-0" FOR24" PIPEAND SMAl.1.ER
SlD. PRECAST
CONC.4' DIAM.
5'-0" FOR 2r
to 39" PIPE
6'-0" FOR42" AND LARGERPIPE
CONESECTION 3. JOINTSMAYBE CASTBELL-UPOR SPIGOT-UP.
4. EITHERFORMRECESSIN BASETO MATCHRISER
JOINTOR SET RISERSECTION IN CAST-IN-PLACE
BASETO DEPTHOF JOINT.
5. MATCHCRO~ OF EXIS11NG PIPEIF PROPOSED
SEYimIS SMAU.ER THANEXIS11NG ~.
OTHERWISE MATCHINVERTOF EX1S11NG ~­
6. SETPRECAST CONESECTION SO COVER15 DIRECllY
OPPOSITETHEDO~SlREAM ~­
SlD. PRECAST CDNC.
RISER,4' DIAM,
• 7. PIPESURFACE SHAl.1.BE Q.£AN ANDCOATED
WITHA BONDING AGENTBEFORE CASllNG
CONCRETE AGAINST IT.
8. DESIGNAND ORUSEOF THISMETHOD IS AT THESOLE
DISCRETIONOF'THEPWCSA,

SlD, PRECAST
CONC.
A.ATTOPREDUCER

6" MIN. ---1


i---- -&m .• PRECAST
SEENOTE2
- :R----t
CONC.RISI:
T2'-MIN.

JOINTSEALANT
COMPOUND,
TYP.
_L
•..

REMOVE
TOP OF PIPE

EXISTING
SEWERPIPE PROPOSED
SEE

3• : ~ .!' .

-----!....
·}\::4·:.--.\. :·.~·:
~ 4•

~
6 MIL POLYFILM
BETWEEN STONEBASE
#5 0 12· cc AND CONCRETE.
CAST-IN-PLACE
CLASSA CONCRETE BASE EACHWAY
5000 PSI CONCRETE
#57 STONE(TYP,)

CONSTRUCTION OF MANHOLE
OVER EXISTING SEWER so9.07.01
N.T.S. REV-2017
---~
--­

REMOVE
MANHOLEFRAME& COVER.

0
REMOVE
All ADJUSTMENT
RINGS. 1· ,- · I

.
.
,-·
. .~, .
..
.#:. .,·..
REMOVE 24• FROM
MINIMUM .,.
BLOCKORBRICKMANHOLES.
REMOVECONESECTIONFROM •... .~.
PRECASTMANHOLES.

FILLREMAINING
AREAWITHf57 STONE.
- -­--..

BULKHEAD ALL
CONNECTIONS
TOMANHOLE
WITHA PRE-MIXED,
FAST
SETTING
VOLUMESTABLE,
WATERPPROOF or
CEMENT:
AS DIRECTED
BYSERVICE
FIELD
AUTHORITY INSPECTOR.

~ ·- 4_,"_.....
·__ ._?_4_·_. - 4"-"
.. _·_.4_4_._· _ 4._-·_ .....
4=-
· ·.i......._---'- ........

NOTES:
1. WHEREMANHOLEIS LOCATED
IN PAVEMENT,
PAVEMENT
SHALLBE RESTORED
IN ACCORDANCE
WITHVDOTSTANDARDS.
2. MANHOLES
LOCATED
IN EASEMENT SHALLBE RESTORED
AREAS SIMILAR
TOSURROUNDING
CONOmONS.

ABANDONMENT
OF MANHOLE
N.T.S. S10.07.01
REV-2017
3" </J x 4" HOLE (TYP.)

A A

' '

3/ 4" </J THREADED ANCHOR BOLT or


3/ 4" </J ALLTHREAD ROD WITH 2" </J
WASHERLOCKED BETWEENTWO NUTS
AT EMBEDDEDEND OR 3/ 4" 0 ALLTHREAD
WITH 3" LONG BY 1/2" </J (MIN.) "T"
WELDED ON EMBEDDED END.

FILL ANNULARSPACE WITH


r~~r:
_l .J

NON-SHRINK or EXPANSIVE
PORTLAND CEMENTGROUT. :
.4J. •.
.· :
:].·41
·... T
4" MIN .
...
j . .
U')
w
0:::
... <t:

J
>

..--,__ ____ 6"_MIN~·· -~••


ANCHORBOLT DETAIL

-----VARI ES ____ jI
SECTIONA-A

PRECAST CONCRETE
MANHOLECONE SECTION s11.07.01
N.T.S. REV-2017
COVER FRAME

LOGO

1-1/2" LETTERS,
LABELSHALLREAD
"WATER"FORWATER
TOPVIEW APPLICATIONS
1" , VENTHOLE

,.J ~ 25-1 /2" I_c2-1/2"


1 , ~ TOPVIEW
I 21" I T 2"
SECTION LJ:1"
3/4'!...jI­ r1" -J !-3/4"
1 1 4
,--~ I
1"T
t t---~

1"-f~1i - / " 3/4"


~~ -MAXIMUM3" DRAFT - 3/4"
1~8" ..1 ~~l
CLOSED
PICKHOLE 3/4~ T
ENLARGED SECTION
ALTERNATIVES

1-25-3/4'-' -
z\·
[_-,--6-SSS-,J L
l-2s"+3/B",-1/4'~
BOTTOM
VIEW I
-· ---40"---­
SECTION

NOTES:
1. MACHINEALL BEARING
SURFACESTO BE TRUEAND LEVEL.
2. MANHOLEFRAMEMAYBE GUSSETTED.
3. USEASTMA48 CLASS308 GRAYIRONOR BETTER.
4. CERTIFY
FRAMEAND COVERFORAASHTO H20 LOADING
OR BETTER.
5. RECESSLABELLETTERING
AND LOGO.
6. ADJUSTABLE
FRAME ANDCOVER AS PERMITTED
BY SERVICE
AUTHORITY.

STANDARD MANHOLE

FRAME AND COVER


S12.07.01
N.T.S. REV-2017

COVER FRAME

j l-2H/t'-j _r2-l/2•

,., Ir ,,. iI »-1/2.


T
SECIION
A-A

.cl 1-1-7/1.
1/2-rEcmi
IIDLTHOU:

~··

5/1-11 tapped hall

LUG
DETAIL
NOTES:
1. MACHINE
ALLBEARINGSURFACESTOBETRUEANDLML
2. MANHOLEFRAME MAYBEGUSSETTED.
3. USEASTM M8 CLASS30B GRAY IRONORBETIER.
4. CERTIFY
f'RAME ANDCOYER FORAASHTOH20 LOADING
ORBETTER.
LABEL
5. RECESS ANDLOGO,
LETTERING
&. PROVIDE
3/8• - RUBBER0-RINGGASKETf'ORMANHOLE
SEAT,
7. PROVIDE
FOUR5/8-11 x H/2• STAINLESS STEEL
HEXHEADBOLTS.

WATERTIGHT MANHOLE

FRAME AND COVER


S 13.07 .00
N.T.S. REV-2017
/ MANHOLEFRAMEAND COVER

3/4 11
MANUFACTURER
}ff!;{:
v,i-=-..::........,0,......_
_____ _

SEAL

11
12 MAX. PRO RING OR LADTECH
...............----4ADJUSTING RINGSOR
ADJUSH.4ENT 1---1 OTHERSAS APPROVED 1----1

BY SERVICEAUTHORITY
4 V

4.

PRECASTMANHOLE
CONEl

4
3/4., MANUFACTURER_/'
SEAL
V

PRO RING, LADTECH RING


OR OTHER S14.07.00
N.T.S. REV-2017
A

0
..___ ___ G_A-SK ~
_E__
T

1/8" DIAMETERHOLE(FOR PRESSURERELIEF)


LOCATEHOLE NEAR TOP OF INSERT

NOTES:
1. THE MANHOLEINSERTWILL BE MADE OF NON-CORRODABLEMATERIALS
AND WILL NOT BE DAMAGEDBY SEWERGASESOR ROADOIL.
2. THE INSERTSHALLHAVE TWONYLONSTRAPSFOR LIFTINGTHE INSERT.
THE STRAPSSHALL BE AITACHEDTO THE INSERTWITHSTAINLESS
STEELRIVETS.
3. THE BOWLSHALL BE ± 1/8" THICKAND SHALL BE BEWTEEN6 AND 8'*
11

DEEP.
4. THE INSERTSHALL HAVE A GASKETTO SEAL BETWEENTHE INSERTAND
THE UP OF THE MANHOLEFRAME.

WATERPROOF
MANHOLE INSERT S15.07.00
N.T.S. REV-2017
SECTIONA-A

FOUR3/4• 91x 4• HOLES


EVENLYSPACED
--
1 I­ 32" -­
24• ~

NOTES:
1. CONCETE TO BE 4000 PSI

COMPRESSIVE STRENGTH, MIN.

2. ALL REINFORCING STEELTO MANHOLE


SIZE
MEETCURRENT REQUIREMENTS 4' 5' 6'
OF ASTMSPEC.A-615.
3. MANHOLE SECTIONS TO MEET

A 45• so· 72•


CURRENT REQUIREMENTS
OF B
sa· 72• as·
ASTMSPEC.C-478. C
6" s· r
4. FLATTOP SHALLBE USEDONLY D
s· a· a·
WHENSPECIFICALLY REQUIRED
BY THE PLANSOR WHERETHERE
IS HEIGHTOR INVERTCONFLICT
As Determined By The
CONTRACTOR AND APPROVED
BY THE INSPECTOR.
S. JOINTCONFIGURA TlONMAY BE
CASTBELL- UP OR SPIGOT-UP.
6. ANCHORBOLTSAS SHOWNIN

DETAILS11.07.00

A A
L_ IIWJ:~~~=11===9~1=~~~1 _j

TOP VIEW

PRECASTCONCRETE
MANHOLEFLATTOP S16.07.00
N.T.S. REV-2017
J
A

NOTES:
TOP VIEW

1. CONCRETE TO BE 4000 PSI

COMPRESSIVE STRENGTH, MIN.

2. ALL REINFORCING STEELTO MEET


DIMENSIONS
CURRENT REQUIREMENTS
OF ASTM
5'-4' 6'-4'
SPEC.A-615.
A so· 12·
3. MANHOLE SECTIONTO MEETCURRENT
Requirements Of ASTM B 72• as·
SPEC.C-478. C s· r
4. JOINTCONFlGURA llON MAY BE CAST
D a· a·
BELL-UPOR SPIGOT-UP.

1--4---­ -----+-1-1
4•-10•

4·-o·--1 I
4• MIN. ~=======================~
.I
t
D
i

SECTIONA-A

PRECASTCONCRETE
MANHOLEREDUCER S17.07.00
N.T.S. REV-2017
A A
L_ _J

NOTES:
1. All REINFORCING
TO MEET
REQUIREMENTS
OF CURRENT
ASTMA-615.
TOP VIEW

NOTCHFOR0-RING GASKET

4'-------t • l
~II 2·
MIN
~II
,~-------~
------5'------­
vi~ 4 3/4.MIN.

SECTIONA-A

PRECASTCONCRETEMANHOLE
CONICALREDUCER-5' TO 4' s1s.07.01
N.T.S. REV-2017
\_ FINISHED GRADE
....
..
.•
.... .
• ,d
• • • 4

,.
, . ··. .:- .....

RELINER
® INSIDE DROP BOWL
SECUREDWITH STAINLESS
STEEL FASTENERSW/ OPT.
FORCE LINE HOOD

EXTERNALPIPE COUPLER

RELINER
® STAINLESSSTEEL
STRAPS SECURED
TO STRUCTURE
WITH STAINLESSSTEEL
FASTENERS.AT 4• INTERVALS
(MIN. OF 2) . .
....
'•

. .· 1 FULL JOINT OF
DUCTILE IRON PIPE
(DIP) INTO MANHOLE.

PVC DROP PIPE

....
,.
....

·,

J­ ----l:U.-:r -­ 45• PVC BEND


-:-- ­ ~ -­ .,.::_\ TURNED IN THE
DIRECTIONOF FLOW,
BUILD CHANNEL

RELINER
® DROP END
(OPTIONAL)

INSIDE DROP
MANHOLE DETAIL S19.07.01
REV-2017
NOlES:
1. Fill drop connection trench with Closs B concrete. Drop connection
trench width to be same as approach trench.
2. Manhole shall conform in all other respects to STANDARD4' 1.0.
PRECASTCONCRElEMANHOLEand CONESECTIONdetails.
3. Keep annular space between manhole and pipes free of
concrete, mortar and grout.

Four #4 Rebars to be placed under pipe


4 ta support joint.
4 't> 4

<1
Kor-N-Seol

or cost-In­

place boot

4 I>
4
·.4
Class B Concrete Some pipe
material
Bench Slope
2' Per Foot

Crown of bend shall be


4• above crown of
1' Min (See Note 1)
main sewer
1>
4

Kor-N-Seor

or cost-ln­

ploce boot

4 I>

Min. s· Compacted
#57 STONE

4' MANHOLE WITH


I
OUTSIDE DROP CONNECTION S20.07.01
I N.T.S. REV-2017
l
BACKWATER VALVEJOSAM
SERIES67100 OR EQUAL
4" SCHEDULE
40 GALV.
STEELPIPE (N.P.T.)

:
0
I
°N

C CLAMPSAND ALL-THREADROD.SEE
MANHOLE VENT SUPPORTDETAIL
(DETAIL45)

COREBOREDHOLE(UNLESS
KOR-N-SEAL CAST-IN-PLACEBOOTIS USED)
r> OR

CAST-IN-PLACE
4"x4"PRESSURE
BOOT TREATED
WOODEN
BLOCK

I>

STAINLESS
STEELNUTS
I>

1" x 1/8" STEEL


PIPE CLAMP
<l
4" llf VENT PIPE

I>
I>

NOTES THREADED
ANCHOR

1. ANCHORHOLESSHALLNOTEXTENDTHROUGH MANHOLE
WALL
2. COATPIPECLAMPWITH BITUMASTIC
SEALANT

MANHOLE
VENT
N.T.S. S21.07.01
REV-2017
18" - 24" MAX

CONNECT WIRE
1RACER FDWM1NC SERVICElA1tlW.TO
IIIREfCWMINGUMI USING
DR'l'C0NNWAlDIPROOF
CONNECTOR mowIONCINHCIYAllOHS
(l<NC& YEWJW)

0

36"• IIETER
CROCK~
TOGRINDER
(m!. __
_JllM:EILWIRE _ 1 1/r WIN.P't'C,SCH.40 PUIIP

1 1/2" TRI.{ UNION


IIAl1.VALW:
(FDREXISTING CONDRIONS
ONLY)
ATTACH
INSUlAT[[)
COPPER
f12 LOCATING
WlRE
TOFORCE MAINUSING
PLASTIC
CASlETIES
(SPACING
EVERY5')

NOlIS:
1. USESCIEIUlf40 SOL'ttNT
WElDIE.l ,I SPIC0TPYCP1'E.(220 PSI RA11NC).
2..ALLPl'EC0IHC1IONSWS1'lffllSTNIDFill S'1SIEM
PR£SSUREWfflOIT
1 NPTPl.UC SEPARATING.
3. PRIMlEf12 SOUDCQPPER 1RAC£R WIIEIUlNCEN11RE f'DIICE11A1No!1LAlDW.
CONl£110NTOGRNIER PUMPHOUSING. 1RACERWIREWlL BELOOPED IN BOXSO
'!HAT
ITCANBEEXIDIIED A 11N.Of 18"111M.TOPOFBOX.WIRE ltl BESl1W'PEDTO
w.N NID lA1EIW.USINGPIAS1IC
CMII.ETES PlACEDEVERY 5 f'm,
4, AU.FIT1N)S WU BESCIEIUlf110PYC,(l2D PSI RA11NC)

ATTACH f12 LlltA1lNGWIRE 1D FllRCEw.N USINGP1AS11C


r.18.E1ES (SPACING E\U'f 51

AIW'TATION
FDRFUISIINGSTATION

Otl LOW FORCE


PR£SSlllE w.N

DrJDEND

FLUSHING STATION AND


GRINDER PUMP CONNECTION TO
LOW PRESSURE FORCE MAIN S22.07.00
:ti..L.S.... REV-2017
1. CONCRETE
SHALLBE 4000 PSI COMPRESSIVE
STRENGTI-l,
MIN.
2. ALL REINFORCING
SHAW MEETREOUIRMENTS
OF CURRENT
ASTMSPECA-615.
3. MANHOLE SECTIONS
SHALLMEETREOUIRMENTS
OF CURRENTASTMSPECC-4 78.
4. TAPERED JOINTWilli 0-RING GASKETSHALLMEETREOUIRMENTS
ASTM

SPECS
C-361 & C-443.

5. CASTMANHOLE SECTIONINTOBASE2• OR DEPTI-lOF'JOINT,WHICHEVER


IS DEEPER.
6. JOINTCONFIGURATION
MAY BE CASTBELL-UPOR SPIGOT-UP.
7. SIZEDOGHOUSE 4• MIN.AND a• MAX. LARGERTliAN PIPE O.D.
OPENINGS CHARTA
B. ALL AIR RELEASEPIPINGSHALLBE BRASS. MIN DIMENTIONS
9. FORFORCEMAINSSMALLERTI-IANs• DIAMETER, EXCEPTFORDUCTILEIRON,
FM TO ts• TO 20• TO 35•
CLAMPTI-IEAIR/VACUUMRELEASEVALVETO TI-IEANGLEIRONSUPPORTBRACE.
MH 4' 5' 6'
10. CASTBASEON FIRM,UNDISTURBED SOIL A 4a• so· 72•
8 s· s· 7•
11. STANDARD PRECASTBASESECTION MAY BE USEDFORNEWFORCEMAIN

CONSTRUCTION. BED STANDARD


BASE

ON MIN.5• VDOTNO. 21A. CORE

HOLESFORPIPEMIN. 4• LARGERTHANPIPEO.D. CONFORM TO TI-IISDETAIL

IN ALL OTI-IER
RESPECTS.

~~~~~~~~~~~zi r STANDARD
MANHOLE
FRAMEAND COVER

PRECAST
CONCRETE
FLATTOP
MANHOLE -~-~ .·. : ··.. 4 . ·• ;
~ · ~·.,-----.
·.. '

APPROVED AIR AC.


RELEASEVAL •
ANGLEIRON TOP OF VALVE
SUPPORTBRACE SHALLBE 24•
BOLTEDTO MH BELOWGRADE. ' ··
STEPSMAYBE REQUIRED , WALLS BALL VALVE(TYP.) , '

BALL VALVEOR
CORP.STOP TAPPINGSADDEL. · . .
OR TAPPEDTEE -~j
FILL TO SPRINGLINE Wini -·-·· •

VDOTNO. 21A STONE.

L
•N­ :z
::::E

L rB--------A-------i
_ _ L._
4 SOLIDCONCRETE
BLOCKSAT 90' POINTS_,./

SEWAGE FORCE MAIN AIR or


VACUUM RELEASE ASSEMBLYs23.07.oo
N.T.S. REV-2017
MANHOLE
FRAMES&: COVERSAT GRADE.

CLEANOUT

....I
~
~
0
5
0
=i
•,,., •0
I
.... I
....

'- UNDISllJRBED
EARTH

NOTES:
1. DESIGNBASEDON COMMERCIALLY
AVAILABLEPRE-CASTSEPTICTANK.
2. MINIMUMSTORAGE500 GALLONS.

GREASETRAP S24.07.00
N.T.S.
REV-2017
ONLYALLOWEDWITHSPECIFICPWCSAPERMISSION

CAREFULLY --- ~
w,..c,.¥
TAMPED

BACKFILL

{95i MAXDENSITY)

1/4 B

1/4 D (4• MIN.)

STANDARDCONCRETE
CRADLE

CAREFULLYTAMPEDBACKFILL
95X MAXDENSITY

1/4 D {4• Min.)

1/4 0 (4• MIN.)

STANDARDCONCRETE
ENCASEMENT

(FOR USEWHENAPPROVEDBY DIRECTOR)

NOTES:
1. CONCRETETO BE CLASS•B• UNLESSOlHERWISESPECIFIED.
2. TRENCHWIDlH SHALLBE AS SPECIFIED
OR AS SHOYINON PLANS.

CONCRETECRADLE
AND ENCASEMENT S25.07.00
N.T.S. REV-2017

L-----------~ ­
SIGN: HEIGHT5'-6" ABOVEGRADE
LABELEDFORSERVICE
"WARNING:SEM:RPIPE CROSSING"or
"WARNING:WATERPIPECROSSING•
(TYPICAL2 PLACESAS APPROVEDBY VDOT)
1/2" STEELCABLEM:LDEDTO CASINGAND FASTENED
TO SIGNPOST
EXISTING
ROADWAY

11DDor APPROVED
SERIES
MEGA-LUG
SUBSTITUTE. 2" PIPEDRAIN

SEEPLANSFORCASINGLENGTH

NOTES:
1. CASINGS
SHALLCONFORM TO VDOTCASING SPECIF1CA110NS.
2. SPACECASINGSPACERS ACCORDINGTO PIPEORSPACER MANUFACTURER'S
RECOMMENDATION
OR2 PERSECTION
OF'PIPE,WHICHEVER
REQUIRES
MORE SPACERS,PLUSONE(1) WIDIIN1WO(2) FEETOFfACHEHDOF CASING.
3. PUSHORPULLTHECURRIER PIPETHROUGH lHE CASING AREALWAYS
SOTHATTHEJOINTS COMPRESSED.
4. ALLJOINtsWITl-llN
THECASING
WILLBERESTRAINED USINGMEGA-LUG
SERIES
1100 RESTRAINING or APPROVED
GLANDS SUBSTITUT£.

CASINGPIPE

2• DRAIN(DOWNSlREAM)
APPROVED
STAINLESS
STEEL
CASING
SPACERWITHPOLYMER
or APPROVED
RUNNERS SUBSTIT\JTE.
(SPACERS
TO BECENTER
RESTRAINED
UNLESS
OTHERWISE
NOTED.)

PIPElN CASINGENDVIEW

STEEL CASING
N.T.S. S26.07.01
REV-2017
MIN. 1'

MIN.1'

TOPVIEW

EXISTING
GROUND ~
ELEVATION

~
~ ----­
MIN.2' ABOVETOPOF PIPE

1' (UNLESS
ROCKIS ENCOUNTERED)

NOTES: SIDEVIEW
1. SPACING
TO BE DETERMINED
BY THEDESIGN ENGINEER/INSPECTOR.
2. CLAYDAM(MIN.IMPERVIOUSNESS= 10 -3 CM/SEC)
MATERIALS
3. ALTERNATE INCLUDESSOILMIXEDWITH

CEMENTANDCONCRETE.
(MATERIALS
TO BE APPROVED BY DESIGNENGINEER
PRIOR

TO PLACING.)

CLAY DAM DETAIL


NTS S27.07.00
REV-2017
PWCSA LOGO
N.T.S. S28.07.00
REV-2017

NOTES:

1. CONCRETE SHALLBE 4000 PSI COMPRESSIVE STRENGTH,


MIN.
2. ALL REINFORCING SHALLMEETREQUIREMENTS OF CURRENT
ASTMSPECA-615.
3. MANHOLE SECTIONS SHALLMEETREQUIREMENTS OF CURRENT
ASTMSPECC-478.
4. TAPEREDJOINTWilli 0-RING GASKETSHALLMEETREQUIREMENTS
OF ASTMSPECS C-361 & C-443.
5. CASTMANHOLE SECTIONINTOBASE2• OR DEPTHOF JOINT
WHICHEVER IS DEEPER.
6. SIZEDOGHOUSE OPENINGS4• MIN.
7. CASTBASEON FIRM,UNDISTURBED SOIL
8. STANDARD PRECASTBASESECTION MAY BE USEDFORNEWFORCEMAIN
CONSTRUCTION. BED STANDARD BASEON MIN. 5• WOT NO. 21A. CORE
HOLESFORPIPEMIN. 4• LARGERTI-IANPIPE 0.0. CONFORM TO lHIS DETAIL
IN ALL OTI-IERRESPECTS.

--­ STANDARD
MANHOLE
FRAMEANDCOVER

... : .. -~. ·• .- ·.. .



--­ · .. _

' ..
SS STEPSMAY BE REQUIRED ,
'
/""" TRUEUNION
, BALL VALVE
7 ~·
• Vo ,

FILL TO SPRINGLINEWITH
WOT NO. 21A STONE. LP.F.M.

L2:
I
c-..­
:1:

L_ _ L.._
4 SOLIDCONCRETE
BLOCKSAT 90• POINTS__/

LOW PRESSURE FORCE MAIN


VALVE CLUSTER DETAIL S29.09.01
N.T.S. REV-2017
METERTO BE IN ACCORDANCE
WITHPWCSASTANDARDS

TRAFFICRATEDMANHOLE
COVER
NOTTO HAVEPWCSAUlGO\

.•

...

:.;

....

.....
••• • • .. ff

. ..•
'·.A· .. ·:

SEWERONLYMETER
FOR PROCESSWATER S30.11.00
N.T.S. REV-2017
NE\./ C/0 AT PROPERTY LINE ------­
FINISHED GRADE __:!~---­

TRANSITION GASKETTa
,
XHCI \./ITH PLUG IN C-900
COUPLING.

INVERT or EXISTING LATERAL


MAINAT
CONNECTION
INSULATED#12 TRACER \./IRE
LOOPED AROUNDMAINCONTINUOUS
TD C/D, MAKESPLICES \./ITH BUTT
CONNECTORSAND SHRINK SLEEVES.

NOTES:
1. STAINLESSSTEELSHEARPROOFCOUPLING / lRANSITIONGASKET
TO BE MINIMUM5' FROMLASTPIPE JOINT.
2. REFERTO APPROVED
PRODUCTS
UST FORADDITIONAL
REQUIREMENTS.

SANITARY SEWER LATERAL


REPLACEMENT S31.11.01
N.T.S. REV-2017
..

OPTION
HAtlFORDIP/PVC

PLUG LATERAL
AT MAINOR AS
DIRECTEDBY SERVICE
AUTHORITYINSPECTOR

INVERT OF INVERT CF
MAINAT LATERAL AT
CONNECTION MAIN

TERMINATION OF
SANITARY SEWER LATERAL s32.11.01
N.T.S. REV-2017
BEDDINGAND BACKFILLFOR C-900. C-905 AND POLY-WRAPPED
DIP

ACKFILL AND 4• MIN SIDE\IALL


SHALL BE CRUSHED AGGREGATE
<LESS THAN 1') DR #S7 STONE
A MIN. CF 24' ABOVE CRD\IN
CF PIPE.

12 SOLID COPPER TRACER \/IRE


IF REQUIRED BY SERVICE AUTHORITY
INSPECTOR,

EDDING SHALL BE A MIN, CF 4• CRUSHED


AGGREGATEDR #57 STONE,

SANITARY SEWER LINE


BEDDING AND BACKFILL S33.14.00
N.T.S. REV- 2017
OFFSETTYPE HINGES
TO PERMITFULL 1BO DEG.
SWING
HEAVY DUTY GALVAN
IZED STEEL
LATCH/HASP ASSEMBLYWITH PADLOCK

2• MESH #9 GAUGECHAIN LINK


FABRIC,VINYL COATED,BLACK

4• f57 STONE(TYP.)

3/4• GALVANIZEDPIPE
SOCKETASSEMBLY
EMBEDDEDIN CONCRETE
EXTENDINGDOWNINTO
GRAVEL

1. CONTRACTOR SHALL RELO

MEASURETO CONRRMAREA TO

BE FENCEDAND LOCAllONS OF

GATES ANO SUBMITSHOP

DRAWINGSPRIOR TO INSTALLATION

CHAIN LINK FENCE DETAIL


N.T.S. S34. 14.00
REV-2017