SUMMARY/SOMMAIRE: NEW SIZE CREATION
Application on : Application mode/Modalité d’application :
Application sur : Immediately :immédiatement :
all machines If necessary /si nécessaire : Í
Periodically/périodiquement :
toutes les machines Next service call/lors du prochain passage:

Introduction:

The Photobook is able to manage 8 different sizes: 102, 152, 203, 305 normal and
Lux

To use another size, one of the existing one must be Modified (ex: replace the
12’’/305 LUX for the 10’’/254 Lux) as explain in this document.

Process:

- Select the SU mode (Password is left arrow, up arrow, right arrow, down
arrow and center)

- Insert a USB key (on which you have created on the root a folder named
PBP_SOFT) and select « save parameters ». This will create a file “save.ini”

Open this file “save.ini” on a PC

For example, when replacing the 12’’/305 Lux by 10’’/254 Lux, scroll to the
following chapter:

[Set3]
Nom=305/12' Lux
Param0=70000
Param1=100000
Param2=7
Param3=9
Param6=0
Param7=305

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
CES INFORMATIONS SONT FAITES POUR DES TECHNICIENS ET SONT CONFIDENTIELLES ET NON CONTRACTUELLES.
TECHNICAL INFO EXPRESS Indice
FOR SAVFR 21
INFORMATION EXPRESS TECHNIQUE A
MACHINE: PHOTOBOOK PRO V1+ & V2
Date: 04/04/08 SAV IET N°02V02 ed 01 Page : 2/2

In this chapter:

- Change Nom=305/12' Lux by 254/10’ Lux).


- Change the Param7=305 by 254 (it is very important for this parameter to
respect existing size ex: 89, 102, 127, 152…)

Remark: Do not modify other parameter in this file.


Remark: All these Parameters values can be different from a machine to another.

- Save the file on the USB key, the name of the file must be "save.ini"

- Insert the USB key on the Photobook

- Select the SU mode (Password is left arrow, up arrow, right arrow, down
arrow and center) and select “Load Parameters”

- After downloading this file, check and adjust if necessary the


“edge_adjustment” parameter.