Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Client

DENKO PETROCHEMICAL MANAGEMENT CO., LTD.

Project Management Consultant

SURBANA INTERNATIONAL CONSULTANTS (MYANMAR) CO, LTD.

Main Contractor

SPECIFICATION FOR
ULTRASONIC LEVEL TRANSMITTER
PROJECT DOCUMENT NO. VF003-IN-SPE-0021

DENKO THILAWA OIL STORAGE TANK TERMINAL PROJECT


TVC PROJECT NO. VF-003

Total Page (Including this page): 7 sheets

0 14-Jan-19 For Approval N.N.Luan D.T.Quan T.H.N.Linh N.V.Lanh


REV. DATE DESCRIPTION MADE CHECKED APPROVED AUTH’D

For Project Use only:


Originator Distribution PR CV ME PP EE IN QC Proc Proj Site Owner Total

Project No. of Copy ORG 1 1


DENKO THILAWA OIL STORAGE
TANK TERMINAL PROJECT
TVC Job No. VF-003
SPECIFICATION FOR ULTRASONIC
LEVEL TRANSMITTER
14-Jan-19 Rev.0 Doc. No.: VF003-IN-SPE-0021 Page 2 of 7

Revision History Sheet

Rev. Date Description


0 14-Jan-19 For Approval
INDEX LIST
Ultrasonic Level Transmitter

Item No. Tag No. Area Type Page No. Rev. No Remark

1 400-LT-001 Sump Berth 1 Ultrasonic Level Transmitter 4 0

2 400-LT-002 Sump Berth 2 Ultrasonic Level Transmitter 6 0

Sheet 3 of 7
1 Tag Number 400-LT-001
2 Service Level measurement transmitter in Sump Berth 1
3 P&ID No. VF003-PR-PID-400001
4 Area Classification Location Zone 2 Field
GENERAL
5 Line No. Line Size Schedule - - -
6 Line Internal Diameter Pipe Material - -
7 Equipment No. Application Sump Berth 1
8 Equipment Height -
9 Nozzle No.
10 Upper Fluid Name Fluid Phase - -
11 Lower Fluid Name Fluid Phase Oily waste sewer Liquid
12 Minimum Normal Maximum Units
13 Normal Level 200 - 1000 mm

PROCESS 14 Temperature - AMB 70 °C


CONDITIONS 15 Pressure ATM ATM Barg
16 Dielectric Constant : Upper Lower - -
17 Density 1000 kg/m³
18 Foaming -
19 Corrosive Erosive Toxic No No No
20 Design Temperature Design Pressure 70 ATM Barg
21 Type Model No. Ultrasonic level See line 47
22 Emitted Signal Pattern Conical
23 Beam Angle (deg) Oper. Frequency B.V. B.V.
ELEMENT 24 Sensor Material PVDF
25 Seal Material B.V.
26 Level Max (mm from flange face) 200
27 Level Min (mm from flange face) 1000
28
29 Process Connection 2" NPT (M)
BODY 30 Connection Position Top Mounting
31 Electrical Connection 1/2" NPT (F)
32 Type -
33 Quantity Form - -
34 Rating -
SWITCH
35 Load Type Deadband - -
36 Contacts Open on Level -
37 Explosion Proof Enclosure - -
38 Output System Accuracy 4-20 mA with HART Protocol ±0.25% of span
39 Power Supply Model No. 2 wire, 24 VDC loop powered See line 47
TRANSMITTER 40 Explosion Protection Enclosure Ex d IIA T4 IP 65 as minimum
41 Scale Range Min. Max. 0 % 100 %
42 Housing Material Color Aluminum Mfr.Std
43 LCD Display Remote LCD Indicator Integral LCD Display -
OPTIONS 44 Surge Protection Antenna Extension - -
45 Air Purge -
46 Manufacturer B.V.
47 Model B.V.
PURCHASE
48 Purchase Order No.
49 Serial Number B.V.
50 Drawing No. -
ADDITIONAL 51 Certification Calibration, Material, Test Report
FEATURES
52 Crippled Mode Detection -
53 SIL Level -
Notes: 1. SS tag name to be stamped with Tag No., Manufacturer Name, Model No. shall be provide on the instrument
2. B.V = By Vendor
3. Mfr.Std = Manufacture Standard

Ultrasonic Level Transmitter

0 N.N.Luan 11-Jan-18 For Approval D.T.Quan T.H.N.Linh


No. Made By Date Description Check Appr. Code: Doc. No: VF003-IN-SPE-0021 Sheet: 4 of 7
TTCL VIETNAM CORPORATION LIMITED
1 Tag Number 400-LT-002
2 Service Level measurement transmitter in Sump Berth 2
3 P&ID No. VF003-PR-PID-400001
4 Area Classification Location Zone 2 Field
GENERAL
5 Line No. Line Size Schedule - - -
6 Line Internal Diameter Pipe Material - -
7 Equipment No. Application Sump Berth 2
8 Equipment Height -
9 Nozzle No.
10 Upper Fluid Name Fluid Phase - -
11 Lower Fluid Name Fluid Phase Oily waste water Liquid
12 Minimum Normal Maximum Units
13 Normal Level 200 - 1000 mm

PROCESS 14 Temperature - 35 70 °C
CONDITIONS 15 Pressure ATM Barg
16 Dielectric Constant : Upper Lower - -
17 Density 1000 kg/m³
18 Foaming -
19 Corrosive Erosive Toxic No No No
20 Design Temperature Design Pressure 70 ATM Barg
21 Type Model No. Ultrasonic level See line 47
22 Emitted Signal Pattern Conical
23 Beam Angle (deg) Oper. Frequency B.V. B.V.
ELEMENT 24 Sensor Material PVDF
25 Seal Material B.V.
26 Level Max (mm from flange face) 200
27 Level Min (mm from flange face) 1000
28
29 Process Connection 2" NPT (M)
BODY 30 Connection Position Top Mounting
31 Electrical Connection 1/2" NPT (F)
32 Type -
33 Quantity Form - -
34 Rating -
SWITCH
35 Load Type Deadband - -
36 Contacts Open on Level -
37 Explosion Proof Enclosure - -
38 Output System Accuracy 4-20 mA with HART Protocol ±0.25% of span
39 Power Supply Model No. 2 wire, 24 VDC loop powered See line 47
TRANSMITTER 40 Explosion Protection Enclosure Ex d IIA T4 IP 65 as minimum
41 Scale Range Min. Max. 0 % 100 %
42 Housing Material Color Aluminum Mfr.Std
43 LCD Display Remote LCD Indicator Integral LCD Display -
OPTIONS 44 Surge Protection Antenna Extension - -
45 Air Purge -
46 Manufacturer B.V.
47 Model B.V.
PURCHASE
48 Purchase Order No.
49 Serial Number B.V.
50 Drawing No. -
ADDITIONAL 51 Certification Calibration, Material, Test Report
FEATURES
52 Crippled Mode Detection -
53 SIL Level -
Notes: 1. SS tag name to be stamped with Tag No., Manufacturer Name, Model No. shall be provide on the instrument
2. B.V = By Vendor
3. Mfr.Std = Manufacture Standard

Ultrasonic Level Transmitter

0 N.N.Luan 11-Jan-18 For Approval D.T.Quan T.H.N.Linh


No. Made By Date Description Check Appr. Code: Doc. No: VF003-IN-SPE-0021 Sheet: 6 of 7
TTCL VIETNAM CORPORATION LIMITED

You might also like