17/4/2020 PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output

Support Center Get Support  Training & Webinars jgalviz@dpa.cl 


Online Forum

 
My TechConnect
During this time, we are committed to being with you every step of the way, and it is critical you have the
support you need. We are offering several special remote support programs to help minimize disruptions in
your operations. Login or sign up to learn more...

ID: QA4034 | Access Levels: Everyone

PowerFlex 40/40P drive, Electro-Mechanical


Braking with a Opto/Output
READ LATER:  Email this page  Print

To find an answer using a previous Answer ID, click here

Ask a question... SEARCH

ADD TO FAVORITES

Document ID QA4034

Published Date 02/13/2020

Summary
PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output

Question
What is the procedure to control Electro-Mechanical Braking by one drive Opto output on PowerFlex 40 or 40P
AC drive? 
Top
PowerFlex 40 drive

https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/47164/loc/en_US 1/6
17/4/2020 PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output

PowerFlex 40P drive

Answer
If one of the Opto output 1 or 2 is connected to the user-supplied electromechanical brake coil relay, the settings
will be:

Parameter A058 [Opto Out1 Sel] or Parameter A061 [Opto Out2 Sel] = 22 EM Brk
Cntrl
Parameter A064 [Opto Out Logic] = 0, 1 or 2 value set in accordance with your
adopted wiring
Parameter P037 [Stop Mode] = 8 "Ramp+EM B,CF or 9 Ramp+EM Brk to enable the
electromechanical brake option
Parameter A160 [EM Brk Off Delay] = value set as required
Parameter A161 [EM Brk On Delay] = value set as required
Parameter P034 [Minimum Freq] = value set as required (Must be a Value other than
Zero)

Before your tests, power cycle the drive to make the settings effective

Specifications of the outputs:


Programmable Output form C relay (R1-R2-R3):

Resistive Rating: 3.0A at 30V DC, 3.0A at 125V AC, 3.0A at 240V AC
Inductive Rating: 0.5A at 30V DC, 0.5A at 125V AC, 0.5A at 240V AC

Opto Outputs:
30V DC, 50mA Non-inductive

The Electro Mechanical Brake sequence is detailed in the graph below:


Top

https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/47164/loc/en_US 2/6
17/4/2020 PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output

Wiring illustrations are displayed below;


Top

https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/47164/loc/en_US 3/6
17/4/2020 PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output


Top

https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/47164/loc/en_US 4/6
17/4/2020 PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output

Note: It is necessary to add a recovery diode such as a 1N4004 in inverse parallel with the user-supplied
electromechanical brake coil relay (inductive load) or with the intermediary auxiliary relay (if this last one is
necessary), in order to prevent damage to the Opto output.

For more details, the PowerFlex 40 Adjustable Frequency AC Drive User Manual, Publication 22B-UM001

Was this answer helpful?


Yes No

RATE CONTENT

Recently Viewed

PowerFlex 750 series


Controlling an Electro-
Drives: DeviceLogix Setting a Electro-
Mechanical Brake with
mechanical brake Mechanical Brake on a 
an opto output on
Top
control sample PowerFlex 753 drive
PowerFlex 525 drive.
program
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/47164/loc/en_US 5/6
17/4/2020
p g PowerFlex 40/40P drive, Electro-Mechanical Braking with a Opto/Output

 
DISCLAIMER
This knowledge base web site is intended to provide general technical information on a particular subject or subjects
and is not an exhaustive treatment of such subjects. Accordingly, the information in this web site is not intended to
constitute application, design, software or other professional engineering advice or services. Before making any
decision or taking any action, which might affect your equipment, you should consult a qualified professional advisor.
ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR ACCURACY OF ANY OF THE
DATA CONTAINED IN THIS WEB SITE AND MAY MAKE CHANGES THERETO AT ANY TIME IN ITS SOLE DISCRETION
WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS "AS IS." IN NO EVENT
SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION HAVE BEEN ADVISED ON THE
POSSIBILITY OF SUCH DAMAGES.

ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT OF THE
INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR
A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not