STEP ONE: DISCONNECT THE INLET HOSE AND INSTALL THE METAL SLEEVE P/N RZ-0206
(DM-512, DM-640, DMD-20 & DMD-25), SLEEVE P/N 400-00870 (DMR-300, DMR-400, DMD-300
& DMD-400), RECONNECT THE LINE.
STEP TWO: RUN A 1" ID LINE (DM-512, DM-640, DMD-20 & DMD-25), ¾” ID LINE (DMR-300,
DMR-400, DMD-300 & DMD-400), FROM THE PORT MARKED RETURN BACK TO THE TANK.
PLEASE MAKE SURE THAT THE LINE GOES INTO THE TANK BELOW THE OIL LEVEL WHEN THE
CYLINDER IS FULLY EXTENDED. WHEN THE CYLINDER IS FULLY EXTENDED MOST OF THE OIL IS
IN THE CYLINDER, NOT THE TANK.
STEP THREE: TOP OFF THE FLUID LEVEL AND CHECK THE FUNCTION OF THE PUMP.
PLEASE NOTE: IF INSTALLING A FILTER IN THE THIRD LINE, THE HOSE FROM THE RETURN PORT
TO THE FILTER SHOULD BE 1" ID (DM-512, DM-640, DMD-20 & DMD-25), ¾” ID LINE (DMR-300,
DMR-400, DMD-300 & DMD-400), FROM THE FILTER TO THE TANK THE HOSE SHOULD BE 1-1/4"
ID (DM-512, DM-640, DMD-20,DMD-25, DMR-300, DMR-400, DMD-300 & DMD-400). ALSO THE
FILTERS SHOULD BE CAPABLE OF 90 GPM AS TO NOT BLOW THE FILTERS OFF THE HEADS. WE
RECOMMEND A 25 PSI BYPASS WITH TWO FILTERS AND A FILTER CHANGE INDICATOR GAGE.
PART NUMBERS FOR THE FILTER HEAD, FILTERS AND INDICATOR GAGE:
90 GPM
FILTER HEAD: SP80 (SIDE BY SIDE) FILTER: 70172 (2 REQUIRED)
1- RZ-0206 OR 400-00870
1- SP 80-SIDE BY SIDE (90 GPM) FILTER HEAD
2- FILTERS P/N 70172 (25 MICRON 90 GPM)
1- INDICATOR GAGE
1- 1" OR ¾” ID HOSE (LONG ENOUGH TO REACH FROM PUMP TO FILTER) 1-1/4" ID HOSE (LONG
ENOUGH TO REACH FROM FILTER TO TANK)