Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

2

GENERAL NOTES :-
1125 1. ALL DIMENSIONS ARE IN MILLIMETERS AND
LEVELS IN MILLI METERS UNLESS NOTED
125 875 125 OTHERWISE.
ALL DIMENSIONSTO BE VERIFIED ON SITE &
APPROVED BY THE ENGINEER.
2. GRADE OF CONC. SHALL BE- C-35

125
3. GRADE OF BLINDING CONC. SHALL BE- C-20
4. COVER AS PER STANDARD

1 1 5. REINFORCEMENT HYSD 460

405
655
275 365

75
125
2
PLAN

COVER AS PER STANDARDS


FIN. G. LVL.
COVER AS PER STANDARDS
FIN. G. LVL.
FIN. G. LVL. FIN. G. LVL.

300
300
750

750
200 T12 AT 200 C/C
T12 AT 200 C/C
75 150

75 150
BLINDING CONC.
BLINDING CONC.
WELL COMPACTED EARTH UPTO
T12 AT 200 C/C 98% STANDARD PROCTOR DENSITY
WELL COMPACTED EARTH UPTO
T12 AT 200 C/C 98% STANDARD PROCTOR DENSITY
75 125 875 125 75
75 125 405 125 75

SECTION 1-1
SECTION 2-2

You might also like