PRODUCT DATA SHEET

Sikalastic®-590
ECONOMICAL LIQUID APPLIED ROOF WATERPROOFING WITH IMPROVED PONDING WATER CAP-
ABILITY

DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikalastic®-590 is one component polyurethane – ac- ▪ Good behavior under limited water ponding
rylic dispersion with improved water ponding resist- ▪ UV resistant and resistant to yellowing and weather-
ance, excellent UV resistance, good crack bridging ca- ing
pacity and great esthetics. For manual / spray applica- ▪ Highly elastic and crack-bridging
tion, Sikalastic®-590 can be applied as coating or a re- ▪ Non-toxic and VOC compliant water based coating
inforced liquid applied membrane with Sika® Reemat ▪ One component - ready to use
Premium-120. ▪ Excellent adhesion on porous and non-porous sub-
strates
USES ▪ Seamless waterproofing membrane
▪ Water vapour permeable
▪ For waterproofing solutions in both new construc-
tion and refurbishment projects
▪ For roofs with many details and complex geometry
when accessibility is limited
▪ For cost efficient life cycle extension of failing roofs
▪ For reflective coating to enhance energy efficiency by
reducing cooling costs (Sikalastic®-590 White)

PRODUCT INFORMATION
Composition Polyurethane modified acrylic dispersion.
Packaging 20 kg Plastic pails.
Colour Grey and white
Shelf Life 12 months from date of production if stored properly in original, un-
opened and undamaged sealed packaging.
Storage Conditions The product must be stored properly in dry conditions at temperatures
between +5 °C and +30 °C.
Density ~1.32 kg/L (at +30 °C) (EN ISO 2811-1)

Solid Content ~63 % by weight

TECHNICAL INFORMATION
Tensile Strength Free film (> 7 days) ~1.7 N/mm² (ASTM D412)

Product Data Sheet


Sikalastic®-590
August 2019, Version 02.01
020915151000000020

1/5
Elongation at Break Free film ~360 % (ASTM D412)

Adhesion in Peel Free film (> 7 days) ~1.5 N/mm² (ASTM D7234)

Behaviour after Artificial Weathering Pass, 1000 hours, UVA-340 (ASTM G154)
no cracking, no blister, no delamination, no chalking
Solar Reflectance ~80 % Sikalastic®-590 White (ASTM E903-12)

Thermal Emittance ~0.91 Sikalastic®-590 White (ASTM C1371-15)

Solar Reflectance Index ~100.9 (at 12 W.m-2.K-1) Sikalastic®-590 White (ASTM E1980-11)

SYSTEM INFORMATION
System Structure WATERPROOFING WITHOUT REINFORCEMENT
▪ For UV-stable coating for extend life old roofs or as reflective coating to
enhance energy efficiency.
▪ For detail system build up, please refer to table below :
Coating System Product Consumption
Primer coat Sikalastic®-590 diluted ~0.3 kg/m²
with 10 % water
First coat Sikalastic®-590 ~0.5 kg/m²
Second coat Sikalastic®-590 ~0.5 kg/m²

WATERPROOFING WITH REINFORCEMENT (SIKA®-120 REEMAT)


▪ For cost efficient waterproofing solutions in new construction and refur-
bishment projects.
▪ Sika® Reemat Premium-120 is applied at areas with movements, irregular
substrate or to bridge cracks, joints and seams on the substrate as well as
for details.
▪ For detail system build up, please refer to table below :
Coating System Product Consumption
Primer coat Sikalastic®-590 diluted ~0.3 kg/m²
with 10 % water
First coat* Sikalastic®-590 ~0.3 kg/m²
Second coat Sikalastic®-590 ~0.5 kg/m²
Reinforcement mem- Sika® Reemat Premi- 1 m²
brane um-120
Third coat Sikalastic®-590 ~0.5 kg/m²
Final coat Sikalastic®-590 0.3–0.5 kg/m²
* It may not be applied, if the substrate is good and the primer has covered
substrate with proper consumption and enough material.

APPLICATION INFORMATION
Ambient Air Temperature +15 °C min. / +35 °C max.
Relative Air Humidity 80 % r.h. max
Substrate Temperature +15 °C min. / +35 °C max.
Dew Point Beware of condensation, Surface temperature during application must be
at least 3 °C above dew point.
Substrate Moisture Content < 6 % moisture content.
No rising moisture according to ASTM (Polyethilene-sheet)
No water / moisture / condensation on the substrate.

Product Data Sheet


Sikalastic®-590
August 2019, Version 02.01
020915151000000020

2/5
Waiting Time / Overcoating Before applying Sikalastic®-590 on Sikalastic®-590 diluted with 10 % water
as primer, allow primer to dry:
Substrate Relative Minimum Maximum
Temperature Humidity
+20 °C 50 % ~2 h * Note 1
+30 °C 50 % ~1 h * Note 1
Before applying Sikalastic®-590 on Sikalastic®-590 (without reinforced), al-
low 1st coat to dry:
Substrate Relative Minimum Maximum
Temperature Humidity
+20 °C 50 % ~6 h * Note 1
+30 °C 50 % ~4 h * Note 1
Before applying Sikalastic®-590 on Sikalastic®-590 (reinforced WITH Sika®
Reemat Premium-120), allow material to dry:
Substrate Relative Minimum Maximum
Temperature Humidity
+20 °C 50 % ~24 h * Note 1
+30 °C 50 % ~12 h * Note 1
*Note 1 : After thorough cleaning Sikalastic®-590 can be overworked with
it self at any time
Applied Product Ready for Use Substrate Relative Hu- Touch Dry Rain Resist- Fully Cured
Temperature midity ant
+20 °C 50 % ~2 h ~10 h ~4 d
+30 °C 50 % ~1 h ~6 h ~2 d
Note : Times are approximate and will be effected by changing ambient
conditions particulary temperature and relative humidity. Low temperat-
ure and high relative humidity retard curing, while high temperature and
low relative air humidity accelerate curing progression.

APPLICATION INSTRUCTIONS Brick and stone:


Mortar joints must be sound and preferably flush poin-
SUBSTRATE PREPARATION ted. Use localized reinforcement over joints and prime
before applying Sikalastic®-590.
Cementitious Substrate: Slates, Tiles, etc.:
▪ New concrete should be cured for at least 28 days Ensure all slates/tiles are sound and securely fastened,
and should have a Pull off strength ≥ 1.5 N/mm². replacing obviously broken or missing sections. Fully
▪ Cementitious or mineral based substrates must be glazed tiles must be abraded prior to priming and sub-
prepared mechanically using abrasive blast cleaning sequent treatment with Sikalastic®-590.
or scarifying equipment to remove cement laitance Bituminous Felt:
and to achieve an open textured surface. Ensure that bituminous felt is firmly adhered or mech-
▪ Loose friable material and weak concrete must be anically fixed to the substrate. Bituminous felt should
completely removed and surface defects such as not contain any badly degraded areas. Prime and al-
blowholes and voids must be fully exposed. ways use a totally reinforced system.
▪ Repairs to the substrate, filling of joints, Bituminous Coatings:
blowholes/voids and surface levelling must be car- Bituminous coatings should not have sticky or mobile
ried out using appropriate products from the Sika- surfaces, volatile mastic coatings, or old coal tar coat-
floor®, SikaDur® and SikaGard® range of materials. ings. Prime and always use a totally reinforced system.
▪ High spots must be removed by e.g. grinding. Metals:
▪ Outgassing is a naturally occurring phenomenon of Metals should be in sound condition. Abrade the ex-
concrete that can produce pinholes in subsequently posed surfaces to reveal bright metal. Use locally rein-
applied coatings. The concrete must be carefully as- forcement over joints and fixings.
sessed for moisture content, air entrapment, and sur- Wooden substrates:
face finish prior to any coating work. Installing the Timber and timber based panel roof decks are to be in
membrane either when the concrete temperature is good condition, firmly adhered, or mechanically fixed.
falling or stable can reduce outgassing. It is generally Paints/Coatings:
beneficial, therefore, to apply the embedment coat Ensure the existing material is sound and firmly ad-
in the late afternoon or evening. hered. Remove any oxidized layers and use localized
▪ Prime the substrate and always use a reinforced sys- reinforcement over joints.
tem.
MIXING

Product Data Sheet


Sikalastic®-590
August 2019, Version 02.01
020915151000000020

3/5
Prior to application, stir Sikalastic®-590 thoroughly for removed by hand or scabbling prior to power washing.
1 minute in order to achieve a homogeneous mixture. Airless spray equipment:
Over mixing must be avoided to minimise air entrain- Used only for the roof coating systems. Two spray ap-
ment. plied layers is the minimum requirement. The pump
should have the following parameter:
APPLICATION -min. pressure : 220 bar
-min. output : 5.1 l/min
Prior the application of Sikalastic®-590, the priming -min. Ø nozzle : 0.83 mm (0.033 inch)
coat has to be used and it must have cured tack-free. For example : Wagner Heavycoat HC 940 E SSP Spray
The primer coat is Sikalastic®-590 diluted 10 % water pack
and consumption is ~0.3 kg/m²
For the Waiting Time / Overcoating please refer to the CLEANING OF TOOLS
PDS of the appropriate primer. Damageable areas
(door frame) have to be protected with an adhesive Clean all tools and application equipment with water
tape. immediately after use. Hardened/cured material can
Waterproofing WITHOUT Sika® Reemat Premium- only be removed mechanically.
120:
Sikalastic®-590 is applied in three coats (1 coat is for IMPORTANT CONSIDERATIONS
primer coat & 2 coats are Sikalastic®-590). Prior to the
application of second coat the indicated waiting time ▪ Sikalastic®-590 can be applied on roofs subject to
in the table Waiting Time / Overcoating shall be al- short ponding water.
lowed. ▪ Recommended slope of 1 % should be provided to
Waterproofing WITH Sika® Reemat Premium-120: substrate. (Depending on Roof layout and availability
▪ Apply primer Sikalastic®-590 diluted with 10% water, of Drains and Gutters, minimum could be 0.5 %
consumption approximately 0.3 kg per m². slope).
▪ Apply first coat* of approximately 0.3 kg per m². ▪ Protect the applied material from rain until 24 hours
▪ Apply second coat of approximately 0.5 kg/m² of to get good ponding water capability.
Sikalastic®-590. Work only so far in advance that the ▪ Do not apply Sikalastic®-590 on substrates with rising
material stays liquid. moisture.
▪ Roll in the Sika® Reemat Premium-120 and push into ▪ Always apply during falling ambient and substrate
the wet liquid and ensure full saturation. Overlap- temperature. If applied during rising temperatures
ping of the Sika® Reemat Premium-120 a minimum 5 “pin holing” may occur from rising air.
cm and ensure overlaps are sufficiently wet to bond. ▪ Ensure that temperature does not drop below 15 °C
The roller may require only a little extra material to and that relative humidity does not exceed 80 % un-
keep wetted but no further significant material needs til the Membrane has fully cured.
to be added at this stage. The surface of the rein- ▪ Ensure that Sikalastic®-590 is totally dry and the sur-
forcement should look wet and fully sealed. Then ap- face is without pinholes before applying any top coat.
ply approximately 0.5 kg per m² of Sikalastic®-590 ▪ Do not allow temporary ponding to remain between
with wet on wet system. coats on any horizontal surfaces or until the final
▪ Before applying the final coat, check for upstanding coating has totally cured. Brush or mop surface wa-
reemat fibres. These fibres have to be eliminated by ter away during this time.
using sandpaper. Make sure that all upstanding fibres ▪ In cold climatic zones, Sikalastic®-590 should not be
are abraded. applied on roofs subject to ponding water with sub-
▪ After the coat is dry enough to walk on, Final coat of sequent periods of frost. Otherwise a slop of more
approximately 0.3–0.5 kg per m² of Sikalastic®-590. than 3 % should be provided, or appropriate meas-
Note : * It may not be applied, if the substrate is good ures should be considered.
and the primer has covered substrate with proper con- ▪ Sikalastic®-590 is not recommended to be applied on
sumption and enough material. screed/concrete laid on top of insulation boards. In
TOOLS this case, SikaBit® range of products are more suit-
able.
Drill and paddle: ▪ Sika® Reemat Premium-120 can be used as total rein-
Sikalastic®-590 should be mixed for one minute using a forcement or for partial reinforcements over dynam-
drill and paddle. ic cracks and joints.
Solvent resistant short-piled lamb skin roller: ▪ Do not over coat Sikalastic®-590 with tile, concrete or
Used in the application of Sikalastic®-590 to ensure a others. Sikalastic®-590 is an exposed system.
consistent thickness of the seamless SikaRoof® sys-
tems. BASIS OF PRODUCT DATA
Thick hair brush:
For application of Sikalastic®-590 to all details and All technical data stated in this Product Data Sheet are
penetrations. based on laboratory tests. Actual measured data may
Jet Washer: vary due to circumstances beyond our control.
If dust, vegetation, moss / algae or other contamin-
ants are present on the existing roof, a power washer LOCAL RESTRICTIONS
is required to clean the substrate prior to the applica-
tion of SikaRoof® Systems. Existing chippings should be Please note that as a result of specific local regula-

Product Data Sheet


Sikalastic®-590
August 2019, Version 02.01
020915151000000020

4/5
tions the performance of this product may vary from
country to country. Please consult the local Product
Data Sheet for the exact description of the application
fields.

ECOLOGY, HEALTH AND SAFETY


For information and advice on the safe handling, stor-
age and disposal of chemical products, users shall refer
to the most recent Safety Data Sheet (SDS) containing
physical, ecological, toxicological and other safety-re-
lated data.

LEGAL NOTES
The information, and, in particular, the recommenda-
tions relating to the application and end-use of Sika
products, are given in good faith based on Sika's cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika’s recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.

Sika Kimia Sdn. Bhd.


Lot 689, Nilai Industrial Estate, 71800 Nilai
Negeri Sembilan D.K., Malaysia
Phone: +606-7991762
Fax: +606-7991980
e-mail: info@my.sika.com
Website: www.sika.com.my

Sikalastic-590-en-MY-(08-2019)-2-1.pdf

Product Data Sheet


Sikalastic®-590
August 2019, Version 02.01
020915151000000020

5/5