Hydraulic Design of Canal

Input Data 1.5


Design Discharge = 152 Cumec 0.8320503
Manning's n value = 0.023 4.5762766
Bed slope = 1 in 3553.77 3.0508511 6.8644149 1.125
Bed width = 9m
Side slope = 1 Ver to 1.5 Hor.
Free Board = 0.75 m
Cot ᶿ = 1.5
ᶿ 0.588 = 33.690 Degrees
TOP WIDTH = 2*(YSINθ +Y COSθ COTθ)+Y/Tanθ
= 2 X { 3.05085108 + 6.8644149 + 1.125 }
+ 9
Top Width = 31.08

Calculate FSD
TOP WIDTH= 31.08 m
Area A= Y ( B + Y θ + Y cot θ ) = 112.66 m2

Perimeter P= B + 2 Y θ + 2 Y Cot θ ) = 31.97 m 0.75 m

θ
R = A/P = 3.524 m θ
Slope S = 0.0002814 Y= 5.50 m
For Y = 5.50
Computed Discharge Q= 190.29678 152 = -38.30 cumecs

Velocity = 1.69 m/sec

76
3553.6603

A 94.88 sqm 121.88 sqm 28.5


P 28.830532 m
R 3.2907821
Q 153.08949 5.5

V 1.6135915
Vc 1.6375509 9