Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

Parker Fluid Connectors Group

North American Divisions & Distribution Service Centers

Your complete source for North American Divisions Distribution Service Centers
quality tube fittings, hose &
hose fittings, brass fittings Energy Products Division Buena Park, CA
& valves, quick-disconnect Stafford, TX phone 714 522 8840
couplings, and assembly phone 281 566 4500 fax 714 994 1183
tools, locally available from fax 281 530 5353
a worldwide network of Conyers, GA
authorized distributors. Fluid System Connectors phone 770 929 0330
Division fax 770 929 0230
Fittings: Otsego, MI
Available in inch and metric phone 269 694 9411 Lakeville, MN
sizes covering SAE, BSP, fax 269 694 4614 phone 952 469 5000
DIN, GAZ, JIS, and ISO thread fax 952 469 5729
configurations, manufactured Hose Products Division
from steel, stainless steel, Wickliffe, OH Louisville, KY
brass, aluminum, nylon, and phone 440 943 5700 phone 502 937 1322
thermoplastic. fax 440 943 3129 fax 502 937 4180

Hose, Tubing, and Bundles: Industrial Hose Division Portland, OR


Available in a wide variety of Strongsville, OH phone 503 283 1020
sizes and materials including phone 440 268 2120 fax 503 283 2201
rubber, wire-reinforced, fax 440 268 2230
thermoplastic, hybrid, and Toledo, OH
custom compounds. Parflex Division phone 419 878 7000
Ravenna, OH fax 419 878 7001
Worldwide Availability: phone 330 296 2871 fax 419 878 7420
Parker operates Fluid fax 330 296 8433 (FCG Kit Operations)
Connectors manufacturing
locations and sales offices Quick Coupling Division Canada
throughout North America, Minneapolis, MN Grimsby, ONT
South America, Europe, and phone 763 544 7781 phone 905 945 2274
Asia-Pacific. fax 763 544 3418 fax 905 945 3945

For information, call toll free... Tube Fittings Division


Columbus, OH
1-800-C-PARKER phone 614 279 7070
(1-800-272-7537) fax 614 279 7685

SensoControl Industrial Products


Industrial Sensors and Controllers for Fluid System
Catalog 3883/USA Measurement, Control, Regulation, and Automation
Catalog 3883 USA | March 2010
© 2010 Parker Hannifin Corporation QCD AP 5M 03/2010

Parker Hannifin Corporation


Quick Coupling Division
8145 Lewis Road
Minneapolis, MN 55427
phone 763 544 7781
fax 763 544 3418
www.parker.com/quickcouplings
Catalog 3883 USA Measurement, Control, Regulation and Automation
OFFER OF SALE
The CE mark indicates high-quality equipment which Improper connection of the supply wires can cause dam-
meets European Directives 89/336/EWG and EMVG re- age to the sensor or amplifier! If one pole of the sensor The items described in this document and other documents and descriptions provided by Parker Hannifin
quirements respectively. It is hereby confirmed that the supply voltage is ground automatically by a signal pro- Corporation, its subsidiaries and its authorized distributors (“Seller”) are hereby offered for sale at prices to be
products are in accordance with the following standards: cessing system, a simultaneous grounding of one of the established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the
sensor signal wire should be avoided; this would short- following Terms and Conditions. Buyer’s order for any item described in its document, when communicated to
Electromagnetic compatibility circuit the sensor and thereby lead to damage. Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred
Electromagnetic interference emissions: to as “Products”.
EN 61000-6-3 Do not connect a power supply to the output wires; this
Electromagnetic interference resistance: would lead to permanent damage to the sensor! Ex-
EN 61000-6-2 ceeding the maximum recommended supply voltage 1. Terms and Conditions. Seller’s willingness to offer 10 days of delivery. No other claims against Seller will be al-
indicated in the data sheet would also lead to sensor Products, or accept an order for Products, to or from Buyer is lowed unless asserted in writing within 60 days after delivery
• Electromagnetic interference can influence the use- damage! expressly conditioned on Buyer’s assent to these Terms and or, in the case of an alleged breach of warranty, within 30
ful signal. Conditions and to the terms and conditions found on-line at days after the date within the warranty period on which the
• General EMG concepts should be used in the de- Media compatibility www.parker.com/saleterms/. Seller objects to any contrary defect is or should have been discovered by Buyer. Any
signing of installations and machinery. SensoControl® products in contact with media are not or additional term or condition of Buyer’s order or any other action based upon breach of this agreement or upon any
• To achieve better EMC interference resistance, the produced in an oil and grease-free environment. There- document issued by Buyer. other claim arising out of this sale (other than an action by
deployment of shielded connecting cables is recom- fore these products should not be used for applications 2. Price Adjustments; Payments. Prices stated on the Seller for any amount due to Seller from Buyer) must be
mended (SCK-400-xx-x5). where an explosive oil or oil/gas mixture could occur reverse side or preceding pages of this document are valid commenced within thirteen months from the date of tender
for 30 days. After 30 days, Seller may change prices to reflect of delivery by Seller or, for a cause of action based upon
• Route analog and data cables at a safe distance (eg. acid or compression). (Danger of explosion!) Use
any increase in its costs resulting from state, federal or local an alleged breach of warranty, within thirteen months from
from power cables. only those media which are compatible with the parts in the date within the warranty period on which the defect is or
legislation, price increases from its suppliers, or any change
• A perfect grounding arrangement helps to avoid contact with the media. If you should have any ques- should have been discovered by Buyer.
in the rate, charge, or classification of any carrier. The prices
measurement errors. tions, please refer to the installation manufacturer or to stated on the reverse or preceding pages of this document 6. LIMITATION OF LIABILITY. UPON NOTIFICATION,
the manufacturer of the medium being used (see catalog do not include any sales, use, or other taxes unless so stated SELLER WILL, AT ITS OPTION, REPAIR OR REPLACE A
Always connect the metallic housing with the laid-down 4100 chapter C). specifically. Unless otherwise specified by Seller, all prices DEFECTIVE PRODUCT, OR REFUND THE PURCHASE
quantities. The PE protective earth terminal should be are F.O.B. Seller’s facility, and payment is due 30 days from PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO
connected up with a low ohm value. Measurement of Selection of pressure range the date of invoice. After 30 days, Buyer shall pay interest BUYER FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
the protective ground resistance should take place in When selecting pressure elements do not exceed the on any unpaid invoices at the rate of 1.5% per month or the CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS
accordance with VDE 0701. overload pressure. If the overload pressure is exceed- maximum allowable rate under applicable law. THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY,
ed, mechanical deformation of the pressure cell (accord- 3. Delivery Dates; Title and Risk; Shipment. All de- SERVICING, USE OR LOSS OF USE OF THE PRODUCTS
Power supply ing to the length/frequency and height of the pressure livery dates are approximate and Seller shall not be respon- OR ANY PART THEREOF, OR FOR ANY CHARGES OR
The recommended power supply with which each stan- sible for any damages resulting from any delay. Regardless EXPENSES OF ANY NATURE INCURRED WITHOUT
peak) can result. Note: where there are air inclusions,
dard sensor should be driven is indicated for the indi- of the manner of shipment, title to any products and risk of SELLER’S WRITTEN CONSENT, EVEN IF SELLER HAS
because of the “diesel effect” pressure peaks can occur BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR
vidual sensor series. A low-noise, high quality, constant loss or damage shall pass to Buyer upon tender to the car-
which far exceed the overload pressure. The nominal OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S
rier at Seller’s facility (i.e., when it’s on the truck, it’s yours).
voltage source is recommended. Some specifications, pressure PN of the pressure element (sensor/switch) LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED
Unless otherwise stated, Seller may exercise its judgment
such as sensitivity and thermal sensitivity shift, change should lie above the nominal pressure of the system be- THE PURCHASE PRICE OF THE PRODUCTS.
in choosing the carrier and means of delivery. No deferment
if a supply voltage is used which is not recommended. ing measured. of shipment at Buyers’ request beyond the respective dates 7. Contingencies. Seller shall not be liable for any default
Every sensor is tuned to give peak performance. Usage indicated will be made except on terms that will indemnify, or delay in performance if caused by circumstances beyond
with any other than the indicated power supply leads to Failure to follow this rule can adversely affect the func- defend and hold Seller harmless against all loss and addi- the reasonable control of Seller.
a change in sensor performance. All polarity and ground tional safety and reliability of products, cause personal tional expense. Buyer shall be responsible for any additional 8. User Responsibility. The user, through its own
regulations should be strictly followed. inquiry, property damage, and result in loss of your shipping charges incurred by Seller due to Buyer’s changes analysis and testing, is solely responsible for making the final
guarantee rights. in shipping, product specifications or in accordance with Sec- selection of the system and Product and assuring that all per-
tion 13, herein. formance, endurance, maintenance, safety and warning re-
Products and information subject to change. 4. Warranty. Seller warrants that the Products sold here- quirements of the application are met. The user must analyze
under shall be free from defects in material or workmanship all aspects of the application and follow applicable industry
for a period of twelve months from the date of delivery to standards and Product information. If Seller provides Product
Buyer or 2,000 hours of normal use, whichever occurs first. or system options, the user is responsible for determining that
WARNING – USER RESPONSIBILITY This warranty is made only to Buyer and does not extend such data and specifications are suitable and sufficient for all
to anyone to whom Products are sold after purchased from applications and reasonably foreseeable uses of the Products
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS Seller. The prices charged for Seller’s products are based or systems.
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. upon the exclusive limited warranty stated above, and upon 9. Loss to Buyer’s Property. Any designs, tools, pat-
the following disclaimer: DISCLAIMER OF WARRANTY: terns, materials, drawings, confidential information or equip-
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide THIS WARRANTY COMPRISES THE SOLE AND ENTIRE ment furnished by Buyer or any other items which become
product or system options for further investigation by users having technical expertise. WARRANTY PERTAINING TO PRODUCTS PROVIDED Buyer’s property, may be considered obsolete and may be
HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- destroyed by Seller after two consecutive years have elapsed
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components
and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The
TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANT- without Buyer placing an order for the items which are manu-
user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning ABILITY AND FITNESS FOR A PARTICULAR PURPOSE. factured using such property. Seller shall not be responsible
the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized 5. Claims; Commencement of Actions. Buyer shall for any loss or damage to such property while it is in Seller’s
distributors. promptly inspect all Products upon delivery. No claims for possession or control.
shortages will be allowed unless reported to the Seller within
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data
or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable
and sufficient for all applications and reasonably foreseeable uses of the components or systems.
Industrial Products

Table of Contents:

Section A Industrial Sensors

Pressure Sensors .....................................Page A-2


Explosion Resistant Pressure Sensors ....Page A-5
Market Symbol Key Custom Pressure Sensors ........................Page A-7
Temperature Sensors ...............................Page A-8

Agriculture Automotive Chemical

Section B Industrial Controllers


Construction Forestry Industrial
Equipment
Pressure Controllers ................................Page B-2
Temperature Controllers ..........................Page B-5
Level Controllers ....................................Page B-10
Level/Temperature Controllers ..............Page B-14

Military Mining MRO

Section C Accessories
Oil & Gas Power
Generation Digital Display ...........................................Page C-2
Cables and Plugs ......................................Page C-5
PC Programming Kit ...............................Page C-7
Industrial Sensors

Section A

Pressure Sensors
Page A-2

Pressure Sensors,
Explosion Resistant
Page A-5

Pressure Sensors,
Custom
Page A-7

Temperature Sensors
Page A-8

Parker’s SensoControl Industrial Sensors are ideal


for permanent installation in industrial and mobile
hydraulic applications where continuous system
monitoring is needed. These precision engineered
sensors are rugged in construction and deliver a
high degree
degree of
ofdependability
of dependability
and performance
and performancewith
with superb
superb stability
stability
and resistance
and resistance
to interference.
to
interference.
SensoControl Industrial Products
Catalog 3883 US Pressure Sensors
SCP01 Series
Table of Contents

Applications include:
ä Test and Measurement
ä Hydraulic Power Units
ä Power Generation
ä Mobile Hydraulics
SCP01 Pressure Sensors are industrial pressure
sensors offering long-term stability, resistance to
interference and rugged construction. They are Features:
available in a wide range of standard and configured ä Stainless steel body
to order versions to meet your application needs. ä Compact construction
These sensors are manufactured with the highest ä Shock and vibration proof
Sensors

quality standards for reliable and repeatable ä Resistant to pressure spikes


measurements. ä Accuracy +/- 0.5% FS
SCP01 Series Pressure Sensors
Port Electrical
Part Number Pressure Range (PSI) Electrical Output
Connection Connection
SCP01-0060P-25-07 -14.5 to 60 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
A SCP01-0060P-27-07 -14.5 to 60 4 - 20 mA, 3 wire
male SAE-4 with O-ring
M12 X 1, 4 pin

SCP01-0060P-35-07 -14.5 to 60 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin


7/16-20UNF-2A
SCP01-0060P-37-07 -14.5 to 60 4 - 20 mA, 2 wire M12 X 1, 4 pin
male SAE-4 with O-ring
Controllers

7/16-20UNF-2A
SCP01-0060P-47-07 -14.5 to 60 0 -10V, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-0150P-25-07 -14.5 to 150 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-0150P-27-07 -14.5 to 150 4 - 20 mA, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-0150P-35-07 -14.5 to 150 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-0150P-37-07 -14.5 to 150 4 - 20mA, 2 wire M12 X 1, 4 pin
B male SAE-4 with O-ring
7/16-20UNF-2A
SCP01-0150P-47-07 -14.5 to 150 0 -10V, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-0250P-25-07 -14.5 to 250 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
Accessories

7/16-20UNF-2A
SCP01-0250P-27-07 -14.5 to 250 4 - 20 mA, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-0250P-35-07 -14.5 to 250 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-0250P-37-07 -14.5 to 250 4 - 20 mA, 2 wire M12 X 1, 4 pin
male SAE-4 with O-ring
7/16-20UNF-2A
SCP01-0250P-47-07 -14.5 to 250 0 -10V, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring

A-2 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Sensors
SCP01 Series

SCP01 Series Pressure Sensors


Port Electrical
Part Number Pressure Range (PSI) Electrical Output
Connection Connection

Table of Contents
SCP01-1000P-25-07 0 to 1000 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-1000P-27-07 0 to 1000 4 - 20 mA, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-1000P-35-07 0 to 1000 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-1000P-37-07 0 to 1000 4 - 20 mA, 2 wire M12 X 1, 4 pin
male SAE-4 with O-ring
7/16-20UNF-2A
SCP01-1000P-47-07 0 to 1000 0 -10V, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-3000P-25-07 0 to 3000 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-3000P-27-07 0 to 3000 4 - 20 mA, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-3000P-35-07 0 to 3000 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin

Sensors
7/16-20UNF-2A
SCP01-3000P-37-07 0 to 3000 4 - 20 mA, 2 wire M12 X 1, 4 pin
male SAE-4 with O-ring
7/16-20UNF-2A
SCP01-3000P-47-07 0 to 3000 0 -10V, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-5000P-25-07 0 to 5000 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
7/16-20UNF-2A
SCP01-5000P-27-07 0 to 5000 4 - 20 mA, 3 wire M12 X 1, 4 pin
male SAE-4 with O-ring
SCP01-5000P-35-07 0 to 5000 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin A
7/16-20UNF-2A
SCP01-5000P-37-07 0 to 5000 4 - 20 mA, 2 wire M12 X 1, 4 pin
male SAE-4 with O-ring
7/16-20UNF-2A
SCP01-5000P-47-07 0 to 5000 0 -10V, 3 wire M12 X 1, 4 pin

Controllers
male SAE-4 with O-ring
SCP01-9000P-25-07 0 to 9000 4 - 20 mA, 3 wire 1/4 NPT male M12 X 1, 4 pin
SCP01-9000P-35-07 0 to 9000 4 - 20 mA, 2 wire 1/4 NPT male M12 X 1, 4 pin
SCP01-9000P-45-07 0 to 9000 0 -10V, 3 wire 1/4 NPT male M12 X 1, 4 pin

B
.47 (12) 1.9 (49) MAX

.75 (19) .87 (22)


4 - 20 mA, 0 - 10 V, 4 - 20 V, Accessories
DIA DIA Pin
3 wire 3 wire 2 wire
1 Supply Supply Supply
.87 (22) 2 Signal Output Signal Output Signal Output
Port Connection M12, 4 Pin
HEX
Thread Electrical
Connection
3 Ground Ground -

All dimensions are shown in inches (mm).


4 - - - C

A-3 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Sensors
SCP01 Series

Technical Specifications
Overload Pressure 200% FS
Table of Contents

Burst Pressure 250% FS


Accuracy +/- 0.5% FS
Protection Class IP67
Response Time < 1ms
Long Term Stability < 0.1% FS/a
Load Reversals > 20 M

Physical Properties
Material - Housing 304 SS
Material - Fitting 630 SS
Sensors

Material - Seal Fluorocarbon


Sensing Element Thin Film (poly Si on SiO2)
Pressure Bore 0.024 in.
Long Term Stability < 0.1% FS/a
Load Reversals > 20 M

A
General Data
Electrical Protection Short circuit, reverse polarity, overload production
Supply Voltage 9-30VDC - 4-20mA, 3-wire
12-30VDC – 4-20 mA, 2-wire / 0-10V, 3-wire
Controllers

Temperature Range:
Environmental -40° F to 185° F
Media, Storage -40° F to 257° F
Compensated -4° F to 185° F
Temperature Coefficient < +/- 0.3% FS/10K
Vibration Resistance Meets IEC 60068-2-29

B Shock Resistance Meets IEC 60068 2-32


EMI Compatibility DIN EN 61000-6-3
DIN EN 61000-6-2
Accessories

A-4 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Sensors, Explosion Resistant
SCP-EX Series

Table of Contents
Applications include:
ä Test and Measurement
ä Hydraulic Power Units
ä Power Generation
ä Mobile Hydraulics
SCP-EX Pressure Sensors are industrial pressure
sensors designed for explosion risk applications.
Providing long-term stability and resistance to
electrical interference in a compact design, they are Features:
available in a wide range of standard and configured ä Stainless steel body
to order versions. These sensors are manufactured ä Compact construction
to the highest quality standards for reliable and ä Shock and vibration proof

Sensors
repeatable measurements as well as the safety of ä Resistant to electrical interference
being used in high risk areas. ä Accuracy +/- 0.5% FS

SCP-EX Series Explosion Resistant Pressure Sensors


Pressure Range Port Electrical
Part Number Electrical Output
(PSI) Connection Connection
SCP-1000P-35-06-EX 0 to 1000 4 - 20 mA, 2 wire 1/4 NPT male DIN 34650 EX
7/16-20UNF-2A
A
SCP-1000P-37-06-EX 0 to 1000 4 - 20 mA, 2 wire DIN 34650 EX
male SAE-4 with O-ring
SCP-3000P-35-06-EX 0 to 3000 4 - 20 mA, 2 wire 1/4 NPT male DIN 34650 EX
7/16-20UNF-2A

Controllers
SCP-3000P-37-06-EX 0 to 3000 4 - 20 mA, 2 wire DIN 34650 EX
male SAE-4 with O-ring
SCP-5000P-35-06-EX 0 to 5000 4 - 20 mA, 2 wire 1/4 NPT male DIN 34650 EX
7/16-20UNF-2A
SCP-5000P-37-06-EX 0 to 5000 4 - 20 mA, 2 wire DIN 34650 EX
male SAE-4 with O-ring
SCP-9000P-35-06-EX 0 to 9000 4 - 20 mA, 2 wire 1/4 NPT male DIN 34650 EX

.47 (12) 3.54 (90) MAX


B

Accessories
.75 (19) .87 (22)
DIA DIA

Port Connection 3
.87 (22) Supply
Thread
HEX 1.34 (34) 1 Signal Output
HEX SCP 2
RL C
DIN Electrical
Connection Ground

All dimensions are shown in inches (mm).

A-5 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Sensors, Explosion Resistant
SCP-EX Series

Technical Specifications
Overload Pressure 200% FS
Table of Contents

Burst Pressure 250% FS


Accuracy +/- 0.5% FS
Protection Class IP65
EX Approval ll 2G Eex ia llC T4 (IBExU06ATEX 1045)
Response Time < 1ms
Long Term Stability < 0.1% FS/a
Load Reversals > 20 M

Physical Properties
Material - Housing 304 SS
Sensors

Material - Fitting 630 SS


Material - Seal Fluorocarbon
Sensing Element Thin Film, Poly Si on Si O2
Pressure Bore 0.024 in.

A General Data
Electrical Protection Short circuit, reverse polarity, overload protection
Supply Voltage 12-30VDC – 4-20mA, 2-wire
Temperature Range
Controllers

Environmental -40° to 185° F


Media, Storage -40° to 257° F
Compensated -4° to 185° F
Temperature Coefficient < +/- 0.3% FS/10° K
Vibration Resistance Meets IEC 60068-2-29
Shock Resistance Meets IEC 60068 2-32
EMI Compatibility DIN EN 61000-6-3
B DIN EN 61000-6-2
Accessories

Additional Data
Ignition Class ll 2G Eex ia llC T4 (IBExU06ATEX 1045)
Basic Standard EN 50014; EN 50020
Maximum Supply 30 V; 50 mA; 1 W
Temperature Class T4 (environmental, -40° to 185° F)
Power Supply w / EX Approval
Output Voltage Max 24 VDC
C Output Current Max 50 mA
Ri (at 24 V) 510
Output Signal 4-20 mA, 2-wire

A-6 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Sensors, Custom
SCP-Custom Series

Table of Contents
Applications include:
ä Test and Measurement
ä Hydraulic Power Units
ä Power Generation
ä Mobile Hydraulics
SCP Custom Pressure Sensors are industrial ä Wind Turbines
pressure sensors offering long-term stability,
resistance to interference and rugged construction.
They are available in a wide range of pressures Features:
configured to meet your unique application. These ä Stainless steel case and wetted parts
sensors are manufactured to the highest quality ä Compact construction
standards for reliable and repeatable measure- ä Shock and vibration proof

Sensors
ments. ä Resistant to pressure spikes
ä Accuracy +/- 0.5% FS
Configure a custom pressure sensor to fit your application’s specifications

Use the following check list to provide the information needed to create
a custom pressure sensor for your unique application.
A
1. Specify a pressure range: 2. Specify an electrical output: 3. Specify a port connection:
Pressure Range Options (psi) Electrical Output Options Port Connection
Thread Options

Controllers
-14.5 to 60 0-20 mA
SAE
-14.5 to 150 4-20 mA, 2 wire
NPT
-14.5 to 250 4-20 mA, 3 wire
BSPP
0 to 1000 0-10 V
Metric
0 to 3000 1-5 V
Other
0 to 5000 1-6 V
0 to 9000 0.5 - 4.5 V ratiometric
B
Other (up to 58000) PWM
Other

Accessories
4. Specify a seal material: 5. Specify an electrical connection: 6. Contact:
Port Seal Options Electrical Connection Options
Quick Coupling Division
Nitrile Fixed cable ph: 763-544-7781
Fluorocarbon Plug options fax: 763-544-3418
EPDM M12 X1 qcd_sales@parker.com
Other AMP
Packard
C
Deutsch
DIN EN 175301-803 Form A
Other

A-7 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Sensors
SCT Series
Table of Contents

Applications include:
ä Test and Measurement
ä Hydraulic Power Units
ä Power Generation
ä Mobile Hydraulics

Features:
ä Compact
ä Rapid Reaction Time
SCT Series Temperature Sensors measure system ä Rugged Steel Housing
media temperature quickly and precisely. ä Simple Installation
ä Applications up to 6000 PSI (415 bar)
Sensors

working pressure
ä -13° F to 257° F (-25° C to 125° C)
ä Standard Output Signal
ä Accuracy +/- 2% FS

SCT Series Temperature Sensors


Port
Part Number Temperature Range Electrical Output
Connection
A -13° F to 257° F
SCT-250F-15-07 1/4 NPT male 0 - 20 mA, 3 wire
(-25° C to 125° C)
-13° F to 257° F 7/16-20UNF-2A
SCT-250F-17-07 0 - 20 mA, 3 wire
(-25° C to 125° C) male SAE-4 with O-ring
Controllers

Technical Specifications
Sensing Element Silicon Chip
Material Steel C15K Galvanized
Protection Class IP 65
Seal O-ring: 7,65 x 1,78 FKM
B Measurement Ranges -13° F to 257° F (-25° C to 125° C)
Working Pressure 6000 psi (414 bar)
Electrical Connection M12 X 1, 4 pin
Voltage Supply 11-30 VDC
Accessories

Electrical Output 0-20mA = -58° F to 257° F


Accuracy +/- 2% FS
Rise Time 13.9 s
Working Resistance 250 Ω
Load Reversals > 20 M
Measurement Media Fluid Media (Oil), No Aggressive Media
C Vibration Resistance Meets IEC 60068-2-29
Shock Resistance Meets IEC 60068 2-32
EMI Compatibility DIN EN 61000-6-3
DIN EN 61000-6-2

A-8 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Sensors
SCT Series

Technical Specifications

Table of Contents
Environment Temperature Range -4° F to 158° F (-20° C to 70° C)
Fluid Temperature Range -13° F to 257° F (-25° C to 125° C)
Storage Temperature Range -13° F to 176° F (-25° C to 80° C)

O-ring .75 (19)


M12 X 1, 4 pin
Port Connection HEX
Connector

Sensors
Thread

.28 (7) .73 (18.5)


DIA DIA

.31 (8)
.69 (17.5) 2.36 (60) .79 (20)
0 - 20 mA,
Pin
3 wire A
1 Supply
All dimensions are shown in inches (mm). 2 Signal Output
3 Ground

Controllers
4 -

Connection Designation
B
bn
Supply
Code Wire Color
ws T-Signal
bn Brown

Accessories
ws White
sw
Ground sw Black
Shield
Ground

A-9 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
Industrial Controllers

Section B

Pressure Controllers
Page B-2

Temperature Controllers
Page B-5

Level Controllers
Page B-10

Level / Temperature
Controllers
Page B-14

Parker’s SensoControl Industrial controllers


combine all of the functions of mechanical sensors,
switches, and displays into a single intelligent
instrument. These simple, robust solutions will
accurately regulate the critical operating
parameters (pressure, temperature, and tank level)
for hydraulic and pneumatic systems.
SensoControl Industrial Products
Catalog 3883 US Pressure Controllers
SCPSD Series
Table of Contents

Applications include:
ä Inspection Station
ä Process Control
ä General Machine Construction
ä Pneumatic and Hydraulic Plant Construction

Features:
ä Pressure display
ä Two switching outputs
Parker’s SCPSD Pressure Controller combines the
ä Analog output signal
functions of pressure switch, pressure sensor and
ä Password protection
display in a single instrument.
ä Solid mechanical construction
Sensors

SCPSD Series Pressure Controllers


Pressure Port Electrical Sensing
Part Number Electrical Output
Range (PSI) Connection Connection Element
7/16-20UNF-2A
SCPSD-0060P-17-17 -14.5 to 60 1 sw / 1 analog M12 X 1, 4 pin Ceramic
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-0060P-17-15 -14.5 to 60 2 sw / 1 analog M12 X 1, 5 pin Ceramic
male SAE-4 with O-ring
A 7/16-20UNF-2A
SCPSD-0060P-07-17 -14.5 to 60 2 sw / no analog M12 X 1, 4 pin Ceramic
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-0250P-17-17 -14.5 to 250 1 sw / 1 analog M12 X 1, 4 pin Ceramic
male SAE-4 with O-ring
Controllers

7/16-20UNF-2A
SCPSD-0250P-17-15 -14.5 to 250 2 sw / 1 analog M12 X 1, 5 pin Ceramic
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-0250P-07-17 -14.5 to 250 2 sw / no analog M12 X 1, 4 pin Ceramic
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-1000P-17-17 0 to 1000 1 sw / 1 analog M12 X 1, 4 pin Thin Film
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-1000P-17-15 0 to 1000 2 sw / 1 analog M12 X 1, 5 pin Thin Film
male SAE-4 with O-ring
B SCPSD-1000P-07-17 0 to 1000 2 sw / no analog
7/16-20UNF-2A
M12 X 1, 4 pin Thin Film
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-3000P-17-17 0 to 3000 1 sw / 1 analog M12 X 1, 4 pin Thin Film
male SAE-4 with O-ring
Accessories

7/16-20UNF-2A
SCPSD-3000P-17-15 0 to 3000 2 sw / 1 analog M12 X 1, 5 pin Thin Film
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-3000P-07-17 0 to 3000 2 sw / no analog M12 X 1, 4 pin Thin Film
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-5000P-17-17 0 to 5000 1 sw / 1 analog M12 X 1, 4 pin Thin Film
male SAE-4 with O-ring
7/16-20UNF-2A
SCPSD-5000P-17-15 0 to 5000 2 sw / 1 analog M12 X 1, 5 pin Thin Film
male SAE-4 with O-ring
C SCPSD-5000P-07-17 0 to 5000 2 sw / no analog
7/16-20UNF-2A
M12 X 1, 4 pin Thin Film
male SAE-4 with O-ring
SCPSD-9000P-15-17 0 to 9000 1 sw / 1 analog 1/4 NPT male M12 X 1, 4 pin Thin Film
SCPSD-9000P-15-15 0 to 9000 2 sw / 1 analog 1/4 NPT male M12 X 1, 5 pin Thin Film
SCPSD-9000P-05-17 0 to 9000 2 sw / no analog 1/4 NPT male M12 X 1, 4 pin Thin Film

B-2 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Controllers
SCPSD Series

1.6 (39.5) 1.8 (46.3)

I II

Table of Contents
SensoControl

3.7 (93.5)
bar/PSI

2.9 (73.4)
UNIT

0.79 (20)
SW27

Sensors
0.40 (10)

1.06 (27)
HEX
0.47 (12)

1.3 (32) DIA


Port Connection
Thread
0.75 (19) DIA
All dimensions are shown in inches (mm).

Electrical Connection Options:


M12 X 1, 4 pin
A
M12 X 1, 5 pin
1 switching output / 1 analog output 2 switching outputs / 1 analog output
1 bn 4 3
Supply Supply 1 bn
Supply Supply
4

Controllers
bk 5 4
Switch 1 Output bk
Switch 1 Output
2 wh 2
Analog Output wh
1 2 Switch 2 Output
3 bl 5
Ground gr
Analog Output
3 bl
Ground Ground

Ground

M12 X 1, 4 pin
2 switching outputs

Supply
1 bn
Supply B
4 bk
Switch 1 Output
2 wh
Switch 2 Output
3 bl
Ground

Accessories
Ground

Technical Specifications
Outputs 2 PNP MOSFET switches, optional analog (4-20 mA)
Contact Functions Normally open / closed, window / hysteresis, freely settable
Pressure Switching Point and Display Accuracy +/- 0.5% FS typ. +/- 1.0% FS max. C
Protection Class IP67
Response Speed < 700ms
Long Term Stability < 0.2% FS/a
Load Reversals > 100 M

B-3 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Pressure Controllers
SCPSD Series

Physical Properties
Material - Housing Zinc diecast Z 410; painted
Table of Contents

Material - Fitting Nickel plated brass


Material - Seal Fluorocarbon
Sensing Element Low pressure ceramic, high pressure thin film
Display 4 figure, 7 segment red LED; digit height 0.35 inches (9mm)

Output Quantities
Power Supply 15…30 VDC nominal 24 VDC; protection class 3
Switching Voltage Power supply 1.5 VDC
Switching Current 0.5 A/switch
Short Circuit Current 2.4 A per switch
Analog Output 0/4-20 mA, programmable
Sensors

Temperature Range - Environmental, Media -4° to 185° F


Temperature Range - Storage -40° to 212° F
Temp Coefficient < +/- 0.3% FS/10K
Vibration Resistance Meets IEC 60068-2-29
Shock Resistance Meets IEC 60068 2-32
EMI Compatibility DIN EN 61000-6-3
A DIN EN 61000-6-2
Media Compatibility Water, lubricating oil, hydraulic oil, acids, and alkalis
Controllers

B
Accessories

SCPSD Accessories Cables (ready-made)


Refer to the Accessories in Section C for SCK-400-XX-XX
detailed information on the following items: ä Length and plug-in connection
options available

PC Programming Kit Plugs (separate)


C SCSD-PRG-KIT includes: SCK-XXX
ä ControllerWin software options include:
ä Adapter ä M12, straight and 90 degree
ä Power pack ä DIN

B-4 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Controllers
SCTSD Series

Table of Contents
Applications include:
ä Inspection Station
ä Process Technology
ä General Machine Construction
ä Pneumatic and Hydraulic Plant Construction

Features:
ä Temperature Display
ä Switching Outputs for Control
The SCTSD Temperature Controller combines the ä Analog Output Signals
functions of a temperature switch, temperature ä Password Protection

Sensors
sensor, and display in a single instrument. ä Solid Mechanical construction

SCTSD Series Temperature Controllers


*Adapter Port Electrical
Part Number Temperature Range Electrical Output
Connection Connection
3/4-16UNF-2A
SCTSD-250F-10-07 -40°F to +250°F 1 sw / 1 analog M12 X 1, 4 pin
male SAE-8 using adapter

SCTSD-250F-10-05 -40°F to +250°F 2 sw / 1 analog


3/4-16UNF-2A
M12 X 1, 5 pin
A
male SAE-8 using adapter
3/4-16UNF-2A
SCTSD-250F-00-07 -40°F to +250°F 2 sw / 0 analog M12 X 1, 4 pin
male SAE-8 using adapter

Controllers
* Connection Adapter is required for direct port mounting. See direct mounting configuration and accessories on page B-7.

1.8 (46.3) 1.6 (39.5) Electrical Connection Options:


M12 X 1, 4 pin
I II 1 switching output / 1 analog output
SensoControl

Supply
1 bn
Supply
B
4 bk
Switch 1 Output
3.7 (93.5)
2.9 (73.4)

°C/°F
2 wh
Analog Output
3

Accessories
bl
UNIT Ground

Ground
0.8 (20)

M12 X 1, 5 pin
2 switching outputs / 1 analog output
0.5 (12.7)

4 3 1 bn
Supply Supply
SW27
4 bk
5 Switch 1 Output
1.06 HEX
(27) 1 2
Switch 2 Output
2

5
wh

gr
C
Analog Output
0.6 (14)

3 bl
M12 X 1 Ground
4 or 5 PIN 1.3 (32) DIA
Ground

All dimensions are shown in inches (mm).

B-5 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Controllers
SCTSD Series

Technical Specifications
Outputs 2 PNP MOSFET switches, optional analog (4-20 mA)
Contact Functions Normally open / closed, window / hysteresis, freely settable
Table of Contents

Temperature Switching Point and Display Accuracy (± 0.35% FS, ± 1 digit at 75F)
Protection Class IP67
Response Speed 300 ms
Long Term Stability < 0.1% FS/a
Resolution 1° F

Physical Properties
Material - Housing Zinc diecast Z 410; painted
Material - Foil Polyester
Display 4 figure, 7 segment red LED; digit height 0.35 inches (9mm)
Sensors

General Data
Measuring Element PT 1000 RTD
Electrical Protection Short circuit, reverse polarity, overload production
Power Supply 15…30 VDC nominal 24 VDC; protection class 3
Current Consumption <100mA

A Switching Current Max. 0.7 A/switch


Temperature Range - Media -40° to 257° F
Temperature Range - Environmental -13° to 176° F
Temperature Range - Storage -40° to 185° F
Controllers

Temp Error Coefficient < +/- 0.3% FS/10K


Vibration Resistance Meets IEC 60068-2-6
Shock Resistance Meets IEC 60068 2-29
EMI Compatibility DIN EN 61000-6-3
DIN EN 61000-6-2
Working Pressure 145 PSI
Media Compatibility Non-aggressive fluid media
B
Accessories

B-6 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Controllers
SCTSD Series

SCTSD Controller Mounting Options

Table of Contents
Direct Mounting Configuration:

Accessories for Direct Mounting SCTSD Controller


Connection Adapter SCA-TT-10-SD-S1/2

Temperature Probe (3.9”) SCTT-10-3.9I-07


Connection Adapter
Temperature Probe (5.9”) SCTT-10-5.9I-07
Temperature Probe (9.8”) SCTT-10-9.8I-07

Immersion Tube (3.9”) SCA-TT-10-3.9I-S1/2 Temperature Probe


Immersion Tube (5.9”) SCA-TT-10-5.9I-S1/2

Sensors
Immersion Tube (9.8”) SCA-TT-10-9.8I-S1/2

Immersion Tube
(Optional - only necessary for high
pressure or aggressive media) A

Controllers
Remote Mounting Configuration: SCTSD Controller

Accessories for Remote Mounting


Clamp SCSD-S27
B
Cable (9.5 ft / 3 m) SCK-410-03-45-45
Clamp
Clamp Adapter SCA-TT-10-S1/2

Accessories
Cable
Temperature Probe (3.9”) SCTT-10-3.9I-07
Temperature Probe (5.9”) SCTT-10-5.9I-07
Temperature Probe (9.8”) SCTT-10-9.8I-07 Clamp Adapter
(allows height adjustment)
Immersion Tube (3.9”) SCA-TT-10-3.9I-S1/2
Immersion Tube (5.9”) SCA-TT-10-5.9I-S1/2 Temperature Probe
Immersion Tube (9.8”) SCA-TT-10-9.8I-S1/2 C
Immersion Tube
(Optional - only necessary for high
pressure or aggressive media)

B-7 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Controllers
SCTSD Series

SCTSD Accessories
Table of Contents

0.39 (10) DIA

0.79 (20) DIA


M12 X 1
L 1.10 (28)

Temperature Probe
Part Number L
SCTT-10-3.9I-07 3.9 (100)
SCTT-10-5.9I-07 5.9 (150)
SCTT-10-9.8I-07
Sensors

9.8 (250)

1.8 (46) 1.6 (41.5)


0.57 (14.5) DIA

0.57 (14.5) DIA


A
M12 x 1 M12 x 1
Male Female
Cable
Controllers

Part Number Length


SCK-410-03-45-45 9.85 ft (3 m)

3/4 - 16 UNF 0.6 (14) DIA

B
0.51 (13) DIA

3/4 - 16 UNF
SAE-8
Accessories

L2
L1

Immersion Tube
Part Number L1 L2
SCA-TT-10-3.9I-S1/2 4.8 (122) 4.2 (107)
C SCA-TT-10-5.9I-S1/2 6.8 (172) 6.2 (157)
SCA-TT-10-9.8I-S1/2 10.7 (272) 10.1 (257)

All dimensions are shown in inches (mm) unless otherwise specified.

B-8 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Temperature Controllers
SCTSD Series

SCTSD Accessories

Table of Contents
1.2 (30)
.75 (19)
2.2 (57) HEX

1.06 (27)
HEX

0.55 (14)
Seal

1.6 (40.5)
3/4 - 16 UNF

Clamp Adapter

Sensors
SCA-TT-10-S1/2

0.3 (7) 0.1 (3)


0.7 (19)

SCSD-S27
A

1.6 (41)
1.06 (27)
HEX
1.2 (30)

2.9 (73)

Controllers
3.4 (87)

0.55 (14)
Seal
Clamp
SCSD-S27
1.06 (26.8) DIA 3/4 - 16 UNF

Connection Adapter

All dimensions are shown in inches (mm).


SCA-TT-10-SD-S1/2 B

Additional SCTSD Accessories

Accessories
Refer to the Accessories in Section C for Cables (ready-made)
detailed information on the following items: SCK-400-XX-XX
ä Length and plug-in connection
options available

PC Programming Kit Plugs (separate)


SCSD-PRG-KIT includes: SCK-XXX C
ä ControllerWin software options include:
ä Adapter ä M12, straight and 90 degree
ä Power pack ä DIN

B-9 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level Controllers
SCLSD Series
Table of Contents

Applications include:
ä Hydraulic Power Units
ä Test Stands
ä Industrial Plant and Equipment
ä Power Generation Systems

Features:
ä 290ƕ Rotatable digital display
Parker’s SCLSD Level Controller is an accurate tool ä Vibration resistant
for tank level media measurement. With a resolu- ä Rugged housing (IP67 Rated)
tion of 0.3 inches (7.5mm), this controller provides ä High/low level display
accurate level readings for fluid system monitoring
Sensors

and regulation.

SCLSD Series Level Controllers


Probe Port Electrical Sensing
Part Number Electrical Output
Length Connection Connection Element

A SCLSD-14.6-17-07 14.6 inch 1 sw / 1 analog


1-1/16 - 12 UNF
male SAE-12 with O-ring
M12 X 1, 4 pin
Resistance reed
with float
1-1/16 - 12 UNF Resistance reed
SCLSD-14.6-17-05 14.6 inch 2 sw / 1 analog M12 X 1, 5 pin
male SAE-12 with O-ring with float
1-1/16 - 12 UNF Resistance reed
SCLSD-14.6-07-07 14.6 inch 2 sw / no analog M12 X 1, 4 pin
Controllers

male SAE-12 with O-ring with float


1-1/16 - 12 UNF Resistance reed
SCLSD-20.5-17-07 20.5 inch 1 sw / 1 analog M12 X 1, 4 pin
male SAE-12 with O-ring with float
1-1/16 - 12 UNF Resistance reed
SCLSD-20.5-17-05 20.5 inch 2 sw / 1 analog M12 X 1, 5 pin
male SAE-12 with O-ring with float
1-1/16 - 12 UNF Resistance reed
SCLSD-20.5-07-07 20.5 inch 2 sw / no analog M12 X 1, 4 pin
male SAE-12 with O-ring with float

B
Accessories

B-10 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level Controllers
SCLSD Series

1.56 (39.5)
Electrical Connection Options:

I II M12 X 1, 4 pin

Table of Contents
SensoControl
1 switching output / 1 analog output
1 bn
Supply Supply
mm/inch
% 4 bk

3.6 (91.5)
Switch 1 Output
2 wh
UNIT Analog Output
3 bl
Ground

Ground
.53 (13.5)

1.30 HEX
M12 X 1, 4 pin
(32)
2 switching outputs
1 bn
Supply Supply
< 1.5 (40)

4 bk

Sensors
Switch 1 Output
1-1/16 - 12 UNF Switch 2 Output
2 wh

3 bl
Ground

Ground

M12 X 1, 5 pin
2 switching outputs / 1 analog output
A
4 3 1 bn
Supply Supply
5 4 bk
Switch 1 Output
2 wh
1 2 Switch 2 Output

Controllers
5 gr
Analog Output
L2

L1

3 bl
Ground

Ground

Level
.31 (8) DIA

Accessories

L1
C
L2
Probe Length
Active Range
(measurement range)
14.6 (370) 1.5 (40) - 12.9 (330)
20.5 (520) 1.5 (40) - 18.9 (480) All dimensions are shown in inches (mm).

B-11 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level Controllers
SCLSD Series

Technical Specifications
Outputs 2 PNP MOSFET switches, optional analog (4-20 mA)
Table of Contents

Contact Functions Normally open / closed, window / hysteresis, freely settable


Switching Point and Display Accuracy +/- 1% FS
Protection Class IP67
Response Speed < 700ms
Long Term Stability < 0.1% FS/a
Load Reversals > 20 M
Resolution 0.2 inches (5mm)

Physical Properties
Material - Housing Zinc diecast Z 410; painted
Material - Fitting Nickel plated brass
Sensors

Material - Seal Nitrile


Material - Float Nitrile
Material - Level rod Brass
Sensing Element Resistance reed with float
Display 4 figure, 7 segment red LED; digit height 0.35 inches (9mm)

A General Data
Electrical Protection Short circuit, reverse polarity, overload production
Power Supply 15…30 VDC nominal 24 VDC; protection class 3
Controllers

Switching Voltage Power supply 1.5 VDC


Temperature Range - Environmental -4° to 185° F
Temperature Range - Media, Storage -40° to 212° F
Temperature Range - Compensated -4° to 185° F
Vibration Resistance Meets IEC 60068-2-29
Shock Resistance Meets IEC 60068 2-32
EMI Compatibility DIN EN 61000-6-3
B DIN EN 61000-6-2
Working Pressure 14.5 psi
Accessories

SCLSD Accessories Cables (ready-made)


Refer to the Accessories in Section C for SCK-400-XX-XX
detailed information on the following items: ä Length and plug-in connection
options available

PC Programming Kit Plugs (separate)


C SCSD-PRG-KIT includes: SCK-XXX
ä ControllerWin software options include:
ä Adapter ä M12, straight and 90 degree
ä Power pack ä DIN

B-12 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level Controllers
SCLSD Series

SCLSD Controller Display Options


Inch / mm Display Example

Table of Contents
I II
SensoControl

mm/inch
%

UNIT

SCLTSD- SCLTSD- SCLTSD-


14.6 20.5 14.6 20.5 14.6 20.5

14.6 in 20.5 in

High High High High

Sensors
1.6 (40)

13 19 22.4 28.3
(330) (480) (570) (720)
MAX

A
11.4 (290)

17.3 (440)

Controllers
MIN

1.6 1.6 1.6 1.6 B


(40) (40) (40) (40)

1.6 (40) Low Low Low Low

Accessories

All dimensions are shown in inches (mm).

Offset
= 7.9
Smallest Reverse
Switch Value
Greatest Switch
Value
Smallest Settable distance
between SP and RSP (200) C
RSP SP (SP-RSP)
1.5 (40) 12.9 (330) 0.2 (5)
1.5 (40) 18.9 (480) 0.2 (5)

B-13 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level / Temperature Controllers
SCLTSD Series
Table of Contents

Applications include:
ä Hydraulic Power Units
ä Test Stands
ä Industrial Plant and Equipment
ä Power Generation Systems

Features:
ä 290ƕ Rotatable digital display
Parker’s SensoControl Level /Temperature ä Vibration resistant
Controllers provide a single instrument solution for ä Rugged housing (IP67 Rated)
monitoring two vital system parameters; fluid level ä Dual function, single point access
and temperature. The color coded displays allow the
Sensors

user to easily identify tank and temperature


measurements. This simple, robust solution is
programmable, aiding in the regulation of
critical operating parameters for fluid systems.

SCLTSD Series Level / Temperature Controllers


Port Electrical
Part Number Probe Length Electrical Output
Connection Connection
A 1-1/16 - 12 UNF
SCLTSD-14.6-17-07 14.6 inch 1 sw / 1 analog M12 X 1, 4 pin
male SAE-12 with O-ring
1-1/16 - 12 UNF
SCLTSD-14.6-17-05 14.6 inch 2 sw / 1 analog M12 X 1, 5 pin
male SAE-12 with O-ring
Controllers

1-1/16 - 12 UNF
SCLTSD-14.6-07-07 14.6 inch 2 sw / no analog M12 X 1, 4 pin
male SAE-12 with O-ring
1-1/16 - 12 UNF
SCLTSD-20.5-17-07 20.5 inch 1 sw / 1 analog M12 X 1, 4 pin
male SAE-12 with O-ring
1-1/16 - 12 UNF
SCLTSD-20.5-17-05 20.5 inch 2 sw / 1 analog M12 X 1, 5 pin
male SAE-12 with O-ring
1-1/16 - 12 UNF
SCLTSD-20.5-07-07 20.5 inch 2 sw / no analog M12 X 1, 4 pin
male SAE-12 with O-ring
B
Accessories

B-14 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level / Temperature Controllers
SCLTSD Series

3.1 (79)
Electrical Connection Options:
M12 X 1, 4 pin

Table of Contents
I II I II
SensoControl SensoControl
1 switching output / 1 analog output
1 bn
Supply Supply
mm/inch °C/°F
% 4 bk
Switch 1 Output
2 wh
UNIT UNIT Analog Output

4.2 (107)
3 bl
Ground

Ground

M12 X 1, 4 pin
2 switching outputs
1 bn
Supply Supply
4

Sensors
bk
Switch 1 Output
2
1.5 (40)

Switch 2 Output wh

3 bl
Ground
1-1/16 - 12 UNF
Ground

M12 X 1, 5 pin
2 switching outputs / 1 analog output A
4 3 1 bn
Supply Supply
5 4 bk
Switch 1 Output
2 wh
1 2 Switch 2 Output

Controllers
5 gr
Analog Output
3 bl
Ground
L1
L2

Ground

Level
B
Integrated Temperature Probe

Accessories

L1
C
L2
Probe Length
Active Range
(measurement range)
14.6 (370) 1.5 (40) - 12.9 (330)
20.5 (520) 1.5 (40) - 18.9 (480) All dimensions are shown in inches (mm).

B-15 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level / Temperature Controllers
SCLTSD Series

Technical Specifications
Outputs 2 PNP MOSFET switches, optional analog (4-20 mA)
Contact Functions Normally open / closed, window / hysteresis, freely settable
Table of Contents

Level Switching Point and Display Accuracy +/- 1% FS


Protection Class IP67
Response Speed < 700ms
Long Term Stability < 0.1% FS/a
Load Reversals > 20 M
Level Resolution 0.2 inches (5mm)
Temperature Resolution 1° F

Physical Properties
Material - Housing Zinc diecasting Z 410; painted
Material - Fitting Nickel plated brass
Sensors

Material - Seal Nitrile


Material - Float Nitrile
Material - Level rod Brass
Sensing Element - Level Resistance reed with float
Sensing Element - Temperature PT1000 RTD
Display 4 figure, 7 segment red LED; digit height 0.35 inches (9mm)
A General Data
Measuring Element Resistance reed array with float
Electrical Protection Short circuit, reverse polarity, overload production
Controllers

Power Supply 15…30 VDC nominal 24 VDC; protection class 3


Switching Voltage Power supply 1.5 VDC
Temperature Range - Environmental, Media -4° to 185° F
Temperature Range - Storage -40° to 212° F
Temperature Coefficient < +/- 0.3% FS/10K
Vibration Resistance Meets IEC 60068-2-29
Shock Resistance Meets IEC 60068 2-32
B EMI Compatibility DIN EN 61000-6-3
DIN EN 61000-6-2
Working Pressure 14.5 PSI
Media Compatibility Water, lubricating oil, hydraulic oil, acids, and alkalis
Accessories

Dimensions
Float 0.71 inches wide, 1.38 inches long (18mm wide, 35mm long)
Level Rod 0.31 inches wide (8mm wide)

SCLTSD Accessories
Refer to the Accessories in Section C for
detailed information on the following items:
C
PC Programming Kit Plugs (separate) Cables (ready-made)
SCSD-PRG-KIT includes: SCK-XXX SCK-400-XX-XX
ä ControllerWin software options include: ä Length and plug-in
ä Adapter ä M12, straight and 90 degree connection options
ä Power pack ä DIN available

B-16 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Level / Temperature Controllers
SCLTSD Series

SCLTSD Controller Display Options


Inch / mm Display Example

Table of Contents
I II I II
SensoControl SensoControl

mm/inch °C/°F
%

UNIT UNIT

SCLTSD- SCLTSD- SCLTSD-


14.6 20.5 14.6 20.5 14.6 20.5

14.6 in 20.5 in

Sensors
1.6 (40) High High High High

13 19 22.4 28.3
(330) (480) (570) (720)
MAX

A
11.4 (290)

17.3 (440)

Controllers
MIN

1.6 1.6 1.6 1.6 B


(40) (40) (40) (40)

1.6 (40) Low Low Low Low

Accessories

All dimensions are shown in inches (mm).

Offset
= 7.9
Smallest Reverse Greatest Switch Smallest Settable distance
(200) C
Switch Value Value between SP and RSP
RSP SP (SP-RSP)
1.5 (40) 12.9 (330) 0.2 (5)
1.5 (40) 18.9 (480) 0.2 (5)

B-17 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
Accessories

Section C

Digital Display
Page C-2

Cables and Plugs


Page C-5

PC Programming Kit
Page C-7

Parker’s SensoControl Accessories are designed to


add flexibility and enhance the performance of our
Industrial Sensors and Controllers.
SensoControl Industrial Products
Catalog 3883 US Digital Display

Compatible with:
Parker SensoControl and Other Sensors:
ä Pressure
ä Temperature
Table of Contents

ä Load / Torque
ä Length
ä Flow

Features:
ä Easy to Read Digital Display
ä Programmable
ä Selectable Units
ä Display Ranges Can Be Set
ä Accepts Common Current and Voltage Signals
ä Terminal Block Connection
The SCE-020 converts standard analog signals into ä Loop through Function: Analog Output or Serial
clearly understandable measurement values/units Interface
and displays them to be easily read.
Sensors

SCE-020 Digital Display Includes:


Display SCE-020-02
Power Supply SCSN-410
Data Cable SCK-300-02-31
A
Input
Measurement Error +/- 0.2% of the Display +/- 1 Digit
Measuring Rate 5ms (Limited value scanning every 5ms)
Controllers

Measurement Range Freely selectable (programming)

Display
Display 4-figure 7-segment LED
Display Range -999 to 9999
Digit Height 13mm
Decimal Point Freely programmable
B
Environmental Conditions
Working Temperature Range 32° -140° F
Storage Temperature Range 13° - 176° F
Accessories

Relative Humidity <80%


Protection Class IP44 (<1mm solids, splashing H2O)

Housing
Material PC ABS black
Self-extinguishing to UL94V0
For panel and console mounting
C Frontal Dimensions 96 x 48mm
Mounting Depth 131mm
Connector 12-Pole terminal strip with wire protection
Weight Approximately 0.45 lbs

C-2 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Digital Display

Input 0...20 mA Connection


ANALOG
4...20 mA Detail SENSOR OUT RS-232 SUPPLY OUT 1
0...10 V

Table of Contents
Input 0...20 mA = 150

11...30VDC
0/4...20mA

0/4...20mA
Ω

0...10V

GND

GND

GND
RxD
TxD
Resistance 4...20 mA = 150
Ω
0...10 V = 67 KΩ 1 2 3 4 5 6 7 8 9 10 11 12
Analog Output 0...20 mA
4...20 mA
Working <500 Ω
Resistance of 1.7 (43.5) 3.5 (90)
Analog Output 2.4 (60)
0.3 (8)
Interface RS-232C
0.3 (7.5)
Limiting Value Potential-free
normally open

Sensors
contact
250 V/5 A max

0.6 (14.5)

A
5.2 (131)

2.0 (50) Max

Controllers
1.9 (48) 3.8 (96)
0.2 (5)

B
6.3 (160)
Cut-out dimensions to
panel mount multiple displays 5.5 (140)

Accessories
2.6 (67)
3.0 (77)

All dimensions are shown in inches (mm).

C-3 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Digital Display
Table of Contents

SCE-020-02 used with SCP01 SCE-020-02 used with SCT


Pressure Sensor Temperature Sensor

bar °C

SensoControl SCE-020 SensoControl SCE-020


Sensors

ANALOG ANALOG
SENSOR OUT RS-232 SUPPLY OUT 1 SENSOR OUT RS-232 SUPPLY OUT 1
11...30VDC

11...30VDC
0/4...20mA

0/4...20mA

0/4...20mA

0/4...20mA
0...10V

0...10V
GND

GND
GND

GND

GND

GND
RxD

RxD
TxD

TxD
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
P T
A +Ub +Ub
+24V +24V
GND GND
Controllers

B
Accessories

C-4 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Cables and Plugs

Compatible with:

Table of Contents
ä SensoControl Sensors
ä SensoControl Controllers
ä Others

SensoControl Cables and Plugs are designed in Features:


accordance with the requirements of industrial sen- ä One cable for many requirements
sors and controllers. M12 cables and plugs are ä Interference resistant
shielded to protect against interference and have a ä Various lengths
five pin configuration. Five pin cables are suitable for ä Compact
both four and five pin connections. The five pin cables ä Plug end options

Sensors
are fully compatible with sensor variants having a
four pin plug.

SCK Connecting Cables (open end)


Part Number Cable Length (m) Plug-in Connector
SCK-400-02-45 6.5 ft (2m) M12 socket, straight
SCK-400-02-55 6.5 ft (2m) M12 socket, 90°
SCK-400-05-45 16 ft (5m) M12 socket, straight
A
SCK-400-05-55 16 ft (5m) M12 socket, 90°
SCK-400-10-45 32.5 ft (10m) M12 socket, straight

Controllers
SCK-400-10-55 32.5 ft (10m) M12 socket, 90°

1.6 (41.5)
SCK-400-XX-45

4 3
0.6 (14.5)

B
DIA

1 2

Accessories
Pin Wire Color Code
1.5 (38.5)
SCK-400-XX-55 1 Brown (bn)
2 White (wh)
3 Blue (bl)
1.04 (26.5)

4 Black (bk)
5 Grey (gr)

0.6 (14.5)
All dimensions are shown in inches (mm)
DIA unless otherwise specified.

C-5 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US Cables and Plugs

SCK Separate Plugs


Part Number Plug-in Connector
Table of Contents

SCK-145 M12 socket, straight


SCK-155 M12 socket, 90°
SCK-006 DIN EN 175301-803 form A

SCK-145
2.2 (56)

0.79 (20)
DIA
4 3
Sensors

SCK-155 1 2
2.1 (54)

Pin Wire Color Code

A 1 Brown (bn)
2 White (wh)
3 Blue (bl)
1.6 (37)

4 Black (bk)
Controllers

5 Grey (gr)

0.79 (20)
DIA

B SCK-006
1.8 (~45)
Accessories

1.2 (29.5)

Pin Wire Color Code


1 Yellow (ye)
2 Green (gn)
C 3 Brown (bn)

1.1 (27.5)
DIA

All dimensions are shown in inches (mm).

C-6 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
SensoControl Industrial Products
Catalog 3883 US PC Programming Kit

Table of Contents
Compatible with:
ä Parker SensoControl Controllers

The SCSD-PRG-KIT, PC Programming Kit with Features:


ControllerWIN software makes the setting and ä Easy set up with PC
saving of all parameters possible. The infra- ä Save parameter settings
red adapter connects to the controller, allowing ä Infrared interface
transmission of data to a laptop or PC. Kit ä Password protection
includes adapter, software, and power pack.

Sensors
PC Programming Kit SCSD-PRG-KIT

RS232 Interface
Cable
A

Controllers
Infrared Adapter

B
SensoControl
Controller

Accessories

C
System Prerequisites:
Operating System Win 98/2000/ME/NT/XP
PC/Laptop Connection RS 232 (USB Adapter)
Controller Connection Parker SCXSD/SCOTC Infrared Interface

C-7 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
www.parker.com/quickcouplings
Catalog 3883 USA Measurement, Control, Regulation and Automation
OFFER OF SALE
The CE mark indicates high-quality equipment which Improper connection of the supply wires can cause dam-
meets European Directives 89/336/EWG and EMVG re- age to the sensor or amplifier! If one pole of the sensor The items described in this document and other documents and descriptions provided by Parker Hannifin
quirements respectively. It is hereby confirmed that the supply voltage is ground automatically by a signal pro- Corporation, its subsidiaries and its authorized distributors (“Seller”) are hereby offered for sale at prices to be
products are in accordance with the following standards: cessing system, a simultaneous grounding of one of the established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the
sensor signal wire should be avoided; this would short- following Terms and Conditions. Buyer’s order for any item described in its document, when communicated to
Electromagnetic compatibility circuit the sensor and thereby lead to damage. Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred
Electromagnetic interference emissions: to as “Products”.
EN 61000-6-3 Do not connect a power supply to the output wires; this
Electromagnetic interference resistance: would lead to permanent damage to the sensor! Ex-
EN 61000-6-2 ceeding the maximum recommended supply voltage 1. Terms and Conditions. Seller’s willingness to offer 10 days of delivery. No other claims against Seller will be al-
indicated in the data sheet would also lead to sensor Products, or accept an order for Products, to or from Buyer is lowed unless asserted in writing within 60 days after delivery
• Electromagnetic interference can influence the use- damage! expressly conditioned on Buyer’s assent to these Terms and or, in the case of an alleged breach of warranty, within 30
ful signal. Conditions and to the terms and conditions found on-line at days after the date within the warranty period on which the
• General EMG concepts should be used in the de- Media compatibility www.parker.com/saleterms/. Seller objects to any contrary defect is or should have been discovered by Buyer. Any
signing of installations and machinery. SensoControl® products in contact with media are not or additional term or condition of Buyer’s order or any other action based upon breach of this agreement or upon any
• To achieve better EMC interference resistance, the produced in an oil and grease-free environment. There- document issued by Buyer. other claim arising out of this sale (other than an action by
deployment of shielded connecting cables is recom- fore these products should not be used for applications 2. Price Adjustments; Payments. Prices stated on the Seller for any amount due to Seller from Buyer) must be
mended (SCK-400-xx-x5). where an explosive oil or oil/gas mixture could occur reverse side or preceding pages of this document are valid commenced within thirteen months from the date of tender
for 30 days. After 30 days, Seller may change prices to reflect of delivery by Seller or, for a cause of action based upon
• Route analog and data cables at a safe distance (eg. acid or compression). (Danger of explosion!) Use
any increase in its costs resulting from state, federal or local an alleged breach of warranty, within thirteen months from
from power cables. only those media which are compatible with the parts in the date within the warranty period on which the defect is or
legislation, price increases from its suppliers, or any change
• A perfect grounding arrangement helps to avoid contact with the media. If you should have any ques- should have been discovered by Buyer.
in the rate, charge, or classification of any carrier. The prices
measurement errors. tions, please refer to the installation manufacturer or to stated on the reverse or preceding pages of this document 6. LIMITATION OF LIABILITY. UPON NOTIFICATION,
the manufacturer of the medium being used (see catalog do not include any sales, use, or other taxes unless so stated SELLER WILL, AT ITS OPTION, REPAIR OR REPLACE A
Always connect the metallic housing with the laid-down 4100 chapter C). specifically. Unless otherwise specified by Seller, all prices DEFECTIVE PRODUCT, OR REFUND THE PURCHASE
quantities. The PE protective earth terminal should be are F.O.B. Seller’s facility, and payment is due 30 days from PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO
connected up with a low ohm value. Measurement of Selection of pressure range the date of invoice. After 30 days, Buyer shall pay interest BUYER FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
the protective ground resistance should take place in When selecting pressure elements do not exceed the on any unpaid invoices at the rate of 1.5% per month or the CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS
accordance with VDE 0701. overload pressure. If the overload pressure is exceed- maximum allowable rate under applicable law. THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY,
ed, mechanical deformation of the pressure cell (accord- 3. Delivery Dates; Title and Risk; Shipment. All de- SERVICING, USE OR LOSS OF USE OF THE PRODUCTS
Power supply ing to the length/frequency and height of the pressure livery dates are approximate and Seller shall not be respon- OR ANY PART THEREOF, OR FOR ANY CHARGES OR
The recommended power supply with which each stan- sible for any damages resulting from any delay. Regardless EXPENSES OF ANY NATURE INCURRED WITHOUT
peak) can result. Note: where there are air inclusions,
dard sensor should be driven is indicated for the indi- of the manner of shipment, title to any products and risk of SELLER’S WRITTEN CONSENT, EVEN IF SELLER HAS
because of the “diesel effect” pressure peaks can occur BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR
vidual sensor series. A low-noise, high quality, constant loss or damage shall pass to Buyer upon tender to the car-
which far exceed the overload pressure. The nominal OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S
rier at Seller’s facility (i.e., when it’s on the truck, it’s yours).
voltage source is recommended. Some specifications, pressure PN of the pressure element (sensor/switch) LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED
Unless otherwise stated, Seller may exercise its judgment
such as sensitivity and thermal sensitivity shift, change should lie above the nominal pressure of the system be- THE PURCHASE PRICE OF THE PRODUCTS.
in choosing the carrier and means of delivery. No deferment
if a supply voltage is used which is not recommended. ing measured. of shipment at Buyers’ request beyond the respective dates 7. Contingencies. Seller shall not be liable for any default
Every sensor is tuned to give peak performance. Usage indicated will be made except on terms that will indemnify, or delay in performance if caused by circumstances beyond
with any other than the indicated power supply leads to Failure to follow this rule can adversely affect the func- defend and hold Seller harmless against all loss and addi- the reasonable control of Seller.
a change in sensor performance. All polarity and ground tional safety and reliability of products, cause personal tional expense. Buyer shall be responsible for any additional 8. User Responsibility. The user, through its own
regulations should be strictly followed. inquiry, property damage, and result in loss of your shipping charges incurred by Seller due to Buyer’s changes analysis and testing, is solely responsible for making the final
guarantee rights. in shipping, product specifications or in accordance with Sec- selection of the system and Product and assuring that all per-
tion 13, herein. formance, endurance, maintenance, safety and warning re-
Products and information subject to change. 4. Warranty. Seller warrants that the Products sold here- quirements of the application are met. The user must analyze
under shall be free from defects in material or workmanship all aspects of the application and follow applicable industry
for a period of twelve months from the date of delivery to standards and Product information. If Seller provides Product
Buyer or 2,000 hours of normal use, whichever occurs first. or system options, the user is responsible for determining that
WARNING – USER RESPONSIBILITY This warranty is made only to Buyer and does not extend such data and specifications are suitable and sufficient for all
to anyone to whom Products are sold after purchased from applications and reasonably foreseeable uses of the Products
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS Seller. The prices charged for Seller’s products are based or systems.
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. upon the exclusive limited warranty stated above, and upon 9. Loss to Buyer’s Property. Any designs, tools, pat-
the following disclaimer: DISCLAIMER OF WARRANTY: terns, materials, drawings, confidential information or equip-
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide THIS WARRANTY COMPRISES THE SOLE AND ENTIRE ment furnished by Buyer or any other items which become
product or system options for further investigation by users having technical expertise. WARRANTY PERTAINING TO PRODUCTS PROVIDED Buyer’s property, may be considered obsolete and may be
HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- destroyed by Seller after two consecutive years have elapsed
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components
and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The
TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANT- without Buyer placing an order for the items which are manu-
user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning ABILITY AND FITNESS FOR A PARTICULAR PURPOSE. factured using such property. Seller shall not be responsible
the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized 5. Claims; Commencement of Actions. Buyer shall for any loss or damage to such property while it is in Seller’s
distributors. promptly inspect all Products upon delivery. No claims for possession or control.
shortages will be allowed unless reported to the Seller within
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data
or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable
and sufficient for all applications and reasonably foreseeable uses of the components or systems.
Parker Fluid Connectors Group
North American Divisions & Distribution Service Centers

Your complete source for North American Divisions Distribution Service Centers
quality tube fittings, hose &
hose fittings, brass fittings Energy Products Division Buena Park, CA
& valves, quick-disconnect Stafford, TX phone 714 522 8840
couplings, and assembly phone 281 566 4500 fax 714 994 1183
tools, locally available from fax 281 530 5353
a worldwide network of Conyers, GA
authorized distributors. Fluid System Connectors phone 770 929 0330
Division fax 770 929 0230
Fittings: Otsego, MI
Available in inch and metric phone 269 694 9411 Lakeville, MN
sizes covering SAE, BSP, fax 269 694 4614 phone 952 469 5000
DIN, GAZ, JIS, and ISO thread fax 952 469 5729
configurations, manufactured Hose Products Division
from steel, stainless steel, Wickliffe, OH Louisville, KY
brass, aluminum, nylon, and phone 440 943 5700 phone 502 937 1322
thermoplastic. fax 440 943 3129 fax 502 937 4180

Hose, Tubing, and Bundles: Industrial Hose Division Portland, OR


Available in a wide variety of Strongsville, OH phone 503 283 1020
sizes and materials including phone 440 268 2120 fax 503 283 2201
rubber, wire-reinforced, fax 440 268 2230
thermoplastic, hybrid, and Toledo, OH
custom compounds. Parflex Division phone 419 878 7000
Ravenna, OH fax 419 878 7001
Worldwide Availability: phone 330 296 2871 fax 419 878 7420
Parker operates Fluid fax 330 296 8433 (FCG Kit Operations)
Connectors manufacturing
locations and sales offices Quick Coupling Division Canada
throughout North America, Minneapolis, MN Grimsby, ONT
South America, Europe, and phone 763 544 7781 phone 905 945 2274
Asia-Pacific. fax 763 544 3418 fax 905 945 3945

For information, call toll free... Tube Fittings Division


Columbus, OH
1-800-C-PARKER phone 614 279 7070
(1-800-272-7537) fax 614 279 7685

SensoControl Industrial Products


Industrial Sensors and Controllers for Fluid System
Catalog 3883/USA Measurement, Control, Regulation, and Automation
Catalog 3883 USA | March 2010
© 2010 Parker Hannifin Corporation QCD AP 5M 03/2010

Parker Hannifin Corporation


Quick Coupling Division
8145 Lewis Road
Minneapolis, MN 55427
phone 763 544 7781
fax 763 544 3418
www.parker.com/quickcouplings