ESY9006

3/2 AH-WRT™ - Horizontal


Pump
PREDICTED. USE AS FIRST GUIDE ONLY. USE VOLUTE C2110WRT1

Installation
PUMP IMPELLER LINER FRAME
Discharge: 50 mm Part No: C2145WRT1 Material: Polymer Frame: C
Suction: 75 mm Material: R55 Sub material: R55 Bearing assembly: C005M
Vanes: 4 Mount angle: degrees
Vane: 230 mm
Type: Closed
SHAFT SEAL MINIMUM PASSAGE SIZE
Shaft material: E05 Type: Gland Size: 18 mm

Motor
Motor safety factor: 1.25
Recommended power: 8 kW
Drive Type: B
Motor Type: -
Motor Speed: 1773 rpm
Motor Power: 11 kW
Poles: 4
Drive Ratio: 1.28
Drive Arrangement: CV
HR/ER
Calculation method: Weir standard
HR: 0.93
ER: 0.90

Duty
No of pumps: 1
Friction method: -
DUTY INFORMATION
Slurry head: 13.70 m
Slurry flow rate: 53.48 m³/h
SERVICE FACTORS
NPSHr: - m
Pump Efficiency: 61.3 %
Duty Power: 6.20 kW
Pump Speed: 1388 rpm
Impeller Tip Speed: 16.71 m/s
SLURRY INFORMATION SYSTEM INFORMATION
Solid SG: 3.3 NPSHa: - m
Fluid SG: 1
Slurry SG: 1.72
Solids concentration (w/w): 60 %
Solids concentration (vol): 31.25 %
d50 Particle Size: 60 microns
Maximum Particle Size: - microns
Temperature: 20 °C
pH: -
Yield stress: - Pa
Coefficient of Rigidity: - Pa-s
Slump plate reading: Reading35
FVF - Froth Volume Factor: -
Title Flow Head Speed Efficiency NPSHr NPSHa % Q BEP Text Is primary duty
DP01 53.48 m³/h 13.70 m 1388 rpm 61.3 % - - 91.2 % -

Bearing life
Stage Frame Assembly DE
Life
L10 WE L10
Life
Stress @
DE
Stress @
WE
Stress @
Th Bearing speed Casing pressure

1 C C005M > 100000 > 100000 3% 9% 31 % Lubricate 'G' OK (232 kPa - max 1400
3450rpm kPa)

Maximum Flange loads


SUCTION FLANGE DISCHARGE FLANGE
Axial load (Fz): 5300 N Axial load (Fz): 1400 N
Force in x-y (Fxy): 2650 N Force in x-y (Fxy): 700 N
Bending moment (Mxy): 470 Nm Bending moment (Mxy): 100 Nm
Torsional moment (Mz): 235 Nm Torsional moment (Mz): 50 Nm