Consistence tolerance - slump test


Consistence, measured using the slump test (BS EN 12350-2), is either specified as a class or target.
Although a supplier will endeavour to provide the required value or range, deviations in production and
sampling apply. The following tables give the maximum allowable deviation based on a spot sample
taken from the initial discharge of a ready-mixed concrete truck.

Max. allowable deviation on


Class Slump range range limit (mm)

S1 10 - 40 0 - 60

S2 50 - 90 30 - 110

S3 100 - 150 80 - 170

S4 160 - 210 140 - 230

Due to lack of sensitivity of slump test values less than 10mm or greater than 210mm, it recomended to
only use the test for slump ≥10mm and ≤210mm

Max. allowable deviation on


Target slump (mm) target value (mm)

≤ 40 ± 30
50 - 90
± 40
≥ 100 ± 50
Based on BS 8500-1:2015 +A1: 2016

Slump test apparatus

Acknowledgement: The Concrete Society

Concrete Bookshop - Members receive 40% discount on Concrete Society publications

http://www.concrete.org.uk/fingertips-print.asp?docid=800 1/2
7/2/2018 Print Fingertip: Consistence tolerance - slump test

Identity testing of fresh concrete for properties other than strength

(http://www.concretebookshop.com/identity-testing-of-fresh-concrete-for-
properties-other-than-strength-1499-p.asp)

Slump, Flow table and Slump-flow tests; assessment checklist and reporting

(http://www.concretebookshop.com/slump-flow-table-and-slump-flow-tests-
assessment-checklist-and-reporting-4335-p.asp)

The information contained in this nugget has been provided by The Concrete Society technical staff.

http://www.concrete.org.uk/fingertips-print.asp?docid=800 2/2

You might also like