Professional Documents
Culture Documents
Consistence Tolerance - Slump Test
Consistence Tolerance - Slump Test
S1 10 - 40 0 - 60
S2 50 - 90 30 - 110
Due to lack of sensitivity of slump test values less than 10mm or greater than 210mm, it recomended to
only use the test for slump ≥10mm and ≤210mm
≤ 40 ± 30
50 - 90
± 40
≥ 100 ± 50
Based on BS 8500-1:2015 +A1: 2016
http://www.concrete.org.uk/fingertips-print.asp?docid=800 1/2
7/2/2018 Print Fingertip: Consistence tolerance - slump test
(http://www.concretebookshop.com/identity-testing-of-fresh-concrete-for-
properties-other-than-strength-1499-p.asp)
Slump, Flow table and Slump-flow tests; assessment checklist and reporting
(http://www.concretebookshop.com/slump-flow-table-and-slump-flow-tests-
assessment-checklist-and-reporting-4335-p.asp)
The information contained in this nugget has been provided by The Concrete Society technical staff.
http://www.concrete.org.uk/fingertips-print.asp?docid=800 2/2