Hydraulic Filters

Series FH 

RoHS
These suction filters are designed for installation
between the pump and reservoir tank.
Their main function is to protect the pump.

Operating Element (µm) Accessory (Option) Page


Series Port size
pressure nominal filtration
Differential pressure indicator (CB-H)
Vertical Suction Filter Negative 1/2, 3/4, 1, 1 1/4, 1 1/2, Micromesh Differential pressure indication
1518
Series FHIA pressure 2, 2 1/2, 3, 3 1/2, 4 74, 105, 149 switch (CB-H)
Blanking cap
FH
Differential pressure indicator (CB-H)
Suction Filter with Case Negative 1/2, 3/4, 1, 1 1/4, 1 1/2, Micromesh Differential pressure indication HOW
Series FH99 pressure 2, 2 1/2, 3, 3 1/2, 4 74, 105, 149 switch (CB-H) 1522
Blanking cap
Differential pressure indicator (CB-H)
Suction Guard Differential pressure indication
Negative 1/2, 3/4, 1, 1 1/4, 1 1/2, Micromesh
Series FHG pressure 2, 2 1/2, 3 74, 105, 149
switch (CB-H) 1526
Air breezer
Cap
Differential pressure indicator (CB-H)
Line Filter Max. Paper
3/8, 1/2, 3/4, 1, 1 1/4 Differential pressure indication
Series FH34/44/54/64
3.5, 7, 14,
1 1/2, 2, 2 1/2, 3
5, 10, 20
switch (CB-H)
1530
21 MPa (Micromesh)
Blanking cap
Paper Differential pressure indicator (CB-H)
Vertical Return Filter Max. 5, 10, 20 Differential pressure indication
Series FHBA 1.6 MPa
3/4, 1 1/4, 1 1/2
Micromesh switch (CB-H)
1534
5, 10, 20 Blanking cap
Paper Differential pressure indicator (CB-H)
Return Filter Max. 3/4, 1, 1 1/4, 1 1/2, 2 5, 10, 20 Differential pressure indication
Series FH100 1 MPa 2 1/2, 3 Micromesh switch (CB-H) 1537
74, 105 Blanking cap
Differential pressure indicator (CB-H)
Oil Filter Paper Differential pressure indication
Max.
Series FH150 1 MPa
1/4, 3/8, 1/2 5, 10, 20 switch (CB-H) 1541
(Micromesh) Blanking cap
Bracket

Magnetic Separator
Series FHM
— — — — 1545

1517
Vertical Suction Filter

Series FHIA RoHS

Specifications
No air pockets Fluid Hydraulic fluid
There are no places for air pockets to form. Operating pressure Negative pressure
This prevents damage to the pump and enables
Operating temperature Max. 80°C
normal operation to start immediately.
Cover/Case Aluminum casting
Elimination of all collected matter Main material O-ring NBR or FKM Note)
All collected matter can be disposed of reliably
Seal NBR or EPDM Note)
when the element is replaced. There is no dan-
Material Micromesh
ger of collected matter dropping back into the
tank. Element Nominal filtration 74, 105, 149 µm (200, 150, 100 mesh)
Differential pressure resistance 0.15 MPa
No drain port required
Differential pressure indicator operating pressure 20.0 kPa
The structure of the filter does not contain areas
for drain fluid to collect, so there is no need to Relief valve open pressure 26.7 kPa
manually drain the pump. Note) The material of the O-rings and seals differs depending on the hydraulic fluid used.
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM
Easy element replacement
Simply open the cover to quickly replace the Model/Rated Flow Rate
element without touching the pipes. The ele- Model Flange port size Note) Rated flow rate (L/min)
ment is extracted from the top, so no fluid can FHIA-04 1/2B 30
leak out. FHIA-06 3/4B 50
Compact and lightweight FHIA-08 1B 95
The compact and lightweight design employs FHIA-10 1 1/4B 150
an aluminum casted housing. FHIA-12 1 1/2B 220
Clogging sensor FHIA-16 2B 350
The sensor indicates when the element is be- FHIA-20 2 1/2B 550
coming dirty, facilitating maintenance and help- FHIA-24 3B 770
ing to avoid pump damage such as cavitations.
FHIA-28 3 1/2B 1000
Differential pressure indicator/reset type
Differential pressure indication switch/visual FHIA-32 4B 1300
combined, non-reset type The symbol represented by  indicates the type of applicable hydraulic fluid. N: Petroleum, W: Water-
glycol, Emulsion, V: Phosphoric ester
Note) Fitted with companion flange. (Flange configuration is exclusive to SMC.)

Accessory/Option
Description Part no. Note
CB-56H Petroleum, Water-glycol, Emulsion
Differential pressure indicator
CB-56H-V Phosphoric ester
Differential pressure indication switch CB-57H Petroleum, Water-glycol, Emulsion
(N.C. and N.O. common) CB-57H-V Phosphoric ester
Blanking cap AG-12H Petroleum
(for differential pressure indication AG-12H-W Water-glycol, Emulsion
part) AG-12H-V Phosphoric ester

Flow Characteristics

10
-20
-04

-10

-16
-06

-08

-24

8
-2
Pressure drop (kPa)

-30
-12

1
10 100 1000
Flow rate (L/min)
Conditions Fluid: Turbine oil Class 2 VG56
Viscosity: 45 mm2/s
Filter material: Micromesh
Nominal filtration: 74 µm to 149 µm
1518
Vertical Suction Filter Series FHIA

How to Order

FH I A N 04 M 074 M R
Hydraulic filter Made to Order
Nil None (Standard)
Model X0 Non-standard filtration
I Suction Note) Refer to page 1548 for details.

Type Relief valve


A Vertical R With relief valve
D None (Blanking plate)
Hydraulic fluid
N Petroleum Differential pressure indication
W Water-glycol, Emulsion M Differential pressure indicator
V Phosphoric ester E Differential pressure indication switch Note)
D None (Blanking cap)
Port size Note) N.C. and N.O. common
04 1/2B
06 3/4B Nominal filtration
08 1B 074 74 µm
10 1 1/4B 105 105 µm
12 1 1/2B 149 149 µm
16 2B
20 2 1/2B Element
24 3B M Micromesh
28 3 1/2B
32 4B

Replacement Element Part No.


74 µm 105 µm 149 µm
Port size (Nominal size) Element size
(200 mesh) (150 mesh) (100 mesh)
04 (1/2B) EM001H-074N EM001H-105N EM001H-149N ø65 x 90
06 (3/4B), 08 (1B) EM101H-074N EM101H-105N EM101H-149N ø85 x 110
10 (1 1/4B), 12 (1 1/2B) EM201H-074N EM201H-105N EM201H-149N ø100 x 160
16 (2B) EM301H-074N EM301H-105N EM301H-149N ø120 x 180
20 (2 1/2B), 24 (3B) EM401H-074N EM401H-105N EM401H-149N ø140 x 200
28 (3 1/2B), 32 (4B) EM501H-074N EM501H-105N EM501H-149N ø180 x 260
Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type.
N: Petroleum, Phosphoric ester, W: Water-glycol, Emulsion.
Note 2) Refer to page 1548 for non-standard filtration.
Note 3) Above elements require one element per filter.
FH
Differential Pressure Indication
HOW
Two indication methods are available: differen-  Differential pressure indication switch ∗ Refer to page 1549 for “Microswitch for differ-
tial pressure indicator and differential pressure • Operating pressure—20 kPa ential pressure indication switch”.
indication switch. These can be mounted on all
filter models.
• When a value has been displayed, it will be
automatically reset when the pump is
 Differential pressure indicator stopped. (Non-reset type)
• Once
Operating pressure—20 kPa • This is a visual dual-purpose. Perform ele-
• be displayed
a value is displayed, it will continue to
until reset, even if the pump is
ment replacement when the switch has actu-
ated (when the red ring floats up and covers
stopped. (Reset type) the entire view port).
• Perform element replacement when the red • N.C. and N.O. common
ring floats up and covers the entire view port.

Reset button
COM.

View port N.O.


N.C.

View port G1/2

1519
Series FHIA

Construction/Seal List
Differential pressure indicator Differential pressure
indication switch
w O-ring
Blanking cap
Spring washer
Hexagon socket head cap screw q O-ring

Cover

Case OUT

Relief valve

Element e O-ring Differential pressure indication switch

r Base seal

e O-ring

Companion flange

Hexagon head bolt


IN

Replacement O-ring/Seal List (One each of the seal and O-ring types listed below are required per filter.)
q O-ring order no. w O-ring order no. e O-ring order no.
Port size Applicable hydraulic fluid Material r Base seal order no.
(Nominal size) (Nominal size) (Nominal size)
KA00464 KA00061 KA00458
04 AL-196H
(1A-G70) (1A-G35) (1A-G30)
KA00466 KA00460 KA00062
06 to 08 AL-197H
(1A-G90) (1A-G50) (1A-G45)
KA00453 KA00463 KA00461
10 to 12 Petroleum, AL-198H
(1A-G105) (1A-G65) (1A-G55)
Water-glycol, NBR
KA00787 KA00465 KA00464
16 Emulsion AL-199H
(1A-G125) (1A-G80) (1A-G70)
KA00060 KA00452 KA00065
20 to 24 AL-200H
(1A-G145) (1A-G100) (1A-G95)
KA00792 KA00790 KA00787
28 to 32 AL-201H
(1A-G185) (1A-G140) (1A-G125)
KA00616 KA00696 KA00695
04 AL-196H-V
(4D-G70) (4D-G35) (4D-G30)
KA00704 KA00699 KA00698
06 to 08 AL-197H-V
(4D-G90) (4D-G50) (4D-G45)
KA00688 KA00614 KA00700
10 to 12 FKM AL-198H-V
(4D-G105) (4D-G65) (4D-G55)
Phosphoric ester or
KA00689 KA00702 KA00616
16 EPDM AL-199H-V
(4D-G125) (4D-G80) (4D-G70)
KA00692 KA00610 KA00705
20 to 24 AL-200H-V
(4D-G145) (4D-G100) (4D-G95)
KA00693 KA00691 KA00689
28 to 32 AL-201H-V
(4D-G185) (4D-G140) (4D-G125)
Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM.

Handling Precautions
q Mounting w Operation e Element replacement
• Confirm IN and OUT before connecting. • Operation of the differential pressure indicator • When the pressure difference reaches 20 kPa
• cient
For maintenance, make sure to provide suffi-
space above the filter for removing the
in cold weather, such as during winter, mostly
occurs due to high viscosity, so check wheth-
during filter operation (actuating the differen-
tial pressure indicator), stop operation and ei-
element. er it is from clogging or not after normal op- ther wash or replace the element.
eration starts. • During disassembly and assembly, check
• If the differential pressure indicator is the re-
set type, make sure to reset it after normal
that there is no cracking of or damage to the
O-rings.
operation starts in cold weather such as dur-
ing winter.
• When washing the element, do not wipe it us-
ing a stiff brush or rag.
• When using a differential pressure indication
switch, if a filter clogged signal is incorpo-
• After washing the element, make sure the
base seal is properly mounted.
rated into the sequence circuit of the ma-
chine, make sure to design the system so the
filter clogged signal does not operate until
normal operation starts.

1520
Vertical Suction Filter Series FHIA

Dimensions

Differential pressure indicator

ø16
B

(34)
F
OUT

Removal dimension K
F

OUT
E

C H
Differential pressure indication switch
D

62

(65)
H
IN

F
4xI OUT
øA
øJ
G

FH
HOW

(mm)
Model A B C D E F G H I J K Weight (kg)
FHIA-04 22.2 90 72 116 154 38 60 11 M8 x 25 56 260 1.8
FHIA-06 27.7
110 80 133 177 44 70 11 M8 x 25 70 290 2.7
FHIA-08 34.5
FHIA-10 43.2
128 95 185 234 49 86 15 M10 x 30 86 340 4.6
FHIA-12 49.1
FHIA-16 61.1 152 110 214 268.5 54.5 100 15 M12 x 35 102 370 6.1
FHIA-20 77.1 9.5
176 125 220 290.5 70.5 120 15 M12 x 35 130 410
FHIA-24 90.0 8.0
FHIA-28 102.6 14.0
224 155 280 364.5 84.5 150 15 M16 x 40 166 490
FHIA-32 115.4 13.5

1521
Suction Filter with Case

Series FH99 RoHS

Specifications
Compact and lightweight Fluid Hydraulic fluid
The compact and lightweight design employs Operating pressure Negative pressure
an aluminum casted housing. Operating temperature Max. 80°C
Prevents pump cavitation Cover/Case Aluminum casting
The inlet size is larger than the outlet size to Main material O-ring NBR or FKM Note)
prevent pump cavitation. Seal NBR or EPDM Note)
Easy element maintenance Material Micromesh
Simply open the cover to detach the element Element Nominal filtration 74, 105, 149 µm (200, 150, 100 mesh)
without touching the pipes. Differential pressure resistance 0.2 MPa
Easy-mounting pipes Differential pressure indicator operating pressure 24.0 kPa
There is no mounting orientation, and two types Relief valve open pressure 33.3 kPa
are available: threaded and flange. Note) The material of the O-rings and seals differs depending on the hydraulic fluid used.
Accessories available for a variety of Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM
applications
Available accessories include differential pres- Model/Rated Flow Rate
sure indicators (differential pressure indicator or Port size Note) Rated flow rate
Model
differential pressure indication switch), relief INLET OUTLET (L/min)
valves, and companion flanges. FH990-04 1B 1/2B 20
Clogging sensor FH990-06 1B 3/4B 50
The filter can be fitted with a differential pres- FH990-08 1 1/2B 1B 100
sure indicator (reset type) or differential pres- FH990-10 1 1/2B 1 1/4B 150
sure indication switch (visual combined, non- FH990-12 2B 1 1/2B 200
reset type).
FH990-16 2B 2B 300
FH991-20 2 1/2B 2 1/2B 450
FH991-24 3B 3B 600
FH991-28 3 1/2B 3 1/2B 750
FH991-32 4B 4B 900
Note) Both flange and threaded connections are supported. However, only flange types for FH991-20 to
FH991-32 are compatible. The flange configuration is exclusive to SMC. Tapered threaded types
(female) conforming to JIS B 0203.

Accessory/Option
Description Part no. Note
CB-54H Petroleum, Water-glycol, Emulsion
Differential pressure indicator
CB-54H-V Phosphoric ester
Differential pressure indication switch CB-55H Petroleum, Water-glycol, Emulsion
(N.C. and N.O. common) CB-55H-V Phosphoric ester
Blanking cap AG-12H Petroleum
(for differential pressure indication AG-12H-W Water-glycol, Emulsion
part) AG-12H-V Phosphoric ester

1522
Suction Filter with Case Series FH99

How to Order

FH 9 90 04 0 0 0 M 074
Hydraulic filter Made to Order
Rated pressure Nil None (Standard)
X0 Non-standard filtration
9 Negative pressure
Note) Refer to page 1548 for details.

Construction/Connection
Companion flange
90 Common with L-type threaded and flange
Nil None
91 L-type flange
F With companion flange

Port size (Outlet side) Nominal filtration


04 1/2B 074 74 µm
Differential pressure indication 105 105 µm
06 3/4B
08 1B
0 None 149 149 µm
10 1 1/4B
4 Differential pressure indicator
5 Differential pressure indication switch Note)
Element
12 1 1/2B
M Micromesh
Note) N.C. and N.O. common
16 2B
20 2 1/2B Hydraulic fluid
24 3B Relief valve 0 Petroleum
28 3 1/2B 0 With relief valve 1 Water-glycol, Emulsion
32 4B 1 None 2 Phosphoric ester

Replacement Element Part No. (Including O-ring for element)


With relief valve Without relief valve
Model 74 µm 105 µm 149 µm 74 µm 105 µm 149 µm Element size
(200 mesh) (150 mesh) (100 mesh) (200 mesh) (150 mesh) (100 mesh)
FH990-04/06 EM520-074N EM520-105N EM520-149N EM230-074N EM230-105N EM230-149N ø65 x 90
FH990-08/10 EM620-074N EM620-105N EM620-149N EM330-074N EM330-105N EM330-149N ø82 x 133
FH990-12 EM720-074N EM720-105N EM720-149N EM430-074N EM430-105N EM430-149N ø104 x 177
FH990-16 EM820-074N EM820-105N EM820-149N EM530-074N EM530-105N EM530-149N ø104 x 177
FH991-20 EM920-074N EM920-105N EM920-149N EM630-074N EM630-105N EM630-149N ø132 x 212
FH991-24 EM030-074N EM030-105N EM030-149N EM730-074N EM730-105N EM730-149N ø132 x 212
FH991-28/32 EM130-074N EM130-105N EM130-149N EM830-074N EM830-105N EM830-149N ø155 x 193
Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type.
N: Petroleum, W: Water-glycol, Emulsion, V: Phosphoric ester
Note 2) Refer to page 1548 for non-standard filtration.
Note 3) Above elements require one element per filter.

Construction/Seal List
FH
Replacement O-ring/Seal List (One each of the seal
Differential pressure
indication switch and O-ring types listed below are required per filter.) HOW
Applicable q O-ring w O-ring e Seal and r Seal and
Port
hydraulic Material order no. order no. O-ring order no. O-ring order no.
size
fluid (Nominal size) (Nominal size) (Nominal size) (Nominal size)
KA00815 KA00470 AL-128H
04 to 06 AL-130H
(1A-V85) (1A-P28) AL-129H
KA00812 KA00244 AL-131H
08 to 10 AL-133H
(1A-V100) (1A-P42) AL-132H
Differential pressure indicator Petroleum,
Blanking cap KA00813 KA00808 AL-134H
q O-ring 12 to 16 Water-glycol, NBR AL-135H
(1A-V120) (1A-P60) AL-135H
Element Emulsion
Cover KA00814 KA00810 AL-136H AL-136H
r Seal (O-ring) 20 to 24
Differential pressure (1A-V150) (1A-P90) AL-137H AL-137H
indication switch KA01800 KA00796 KA00813 KA00813
28 to 32
(1A-V175) (1A-P120) (1A-V120) (1A-V120)
KA00731 KA00717 AL-128H-V
04 to 06 AL-130H-V
OUT (4D-V85) (4D-P28) AL-129H-V
KA00727 KA00723 AL-131H-V
08 to 10 AL-133H-V
(4D-V100) (4D-P42) AL-132H-V
FKM
Hexagon socket Phosphoric KA00728 KA00733 AL-134H-V
Relief valve 12 to 16 or AL-135H-V
head cap screw ester (4D-V120) (4D-P60) AL-135H-V
EPDM
Companion flange KA00729 KA00114 AL-136H-V AL-136H-V
20 to 24
e Seal (O-ring) Case (4D-V150) (4D-P90) AL-137H-V AL-137H-V
KA00730 — KA00728 KA00728
28 to 32
w O-ring (4D-V175) (4D-P120) (4D-V120) (4d-V120)
Note) The material of seals (AL-128H-V to AL-137H-V)
IN is EPDM.
1523
Series FH99

Flow Characteristics
Handling Precautions
FH99
q Mounting
• For
Confirm IN and OUT before connecting.
• cientmaintenance, make sure to provide suffi-
space above the filter for removing the

4
10

-2
-2
element.
Pressure drop (kPa)

w Operation

2
/3
• Operation of the differential pressure indicator

8
-2
6
-0 in cold weather, such as during winter, mostly
0
-1

2
8

6
-1
occurs due to high viscosity, so check wheth-
-0

-1
er it is from clogging or not after normal op-
-04 eration starts.
• If the differential pressure indicator is the re-
set type, make sure to reset it after replacing
the element or after normal operation starts in
cold weather such as during winter.
1
10 100 1000
• When using a differential pressure indication
switch and if a filter clogged signal is incorpo-
Flow rate (L/min) rated into the sequence circuit of the ma-
Conditions Fluid: Turbine oil Class 2 VG56 chine, make sure to design the system so the
Viscosity: 45 mm2/s filter clogged signal does not operate until
Filter material: Micromesh normal operation starts.
Nominal filtration: 74 µm
e Element replacement

Differential Pressure Indication • When the pressure difference reaches 24 kPa


during filter operation (actuating the differen-
Two indication methods are available: differen-  Differential pressure indication switch tial pressure indicator), stop operation and ei-
tial pressure indicator and differential pressure • When
Operating pressure—24 kPa ther wash or replace the element.
• that
indication switch. These can be mounted on all
filter models.
• automatically
a value has been displayed, it will be
reset when the pump is
During disassembly and assembly, check
there is no cracking of or damage to the
stopped. (Non-reset type) O-rings.
 Differential pressure indicator
• Once
Operating pressure—24 kPa • ment
This is a visual dual-purpose. Perform ele- • When installing and removing an element, do
not scratch or damage it by touching the cor-
• be displayed
a value is displayed, it will continue to
until reset, even if the pump is
replacement when the switch has actu-
ated (when the red ring floats up and covers ners of the case, etc.
stopped. (Reset type) the entire view port). • When washing the element, do not wipe it us-

• Perform element replacement when the red • N.C. and N.O. common ing a stiff brush or rag.
ring floats up and covers the entire view port.
COM.
Reset button N.O.
N.C.

View port
View port G1/2

∗ Refer to page 1549 for “Microswitch for differ-


ential pressure indication switch”.

1524
Suction Filter with Case Series FH99

Dimensions

Differential pressure
Blanking cap indication switch
Differential
8xT ø16
pressure

(65)
indicator
N
I

(34)
U
OUT
øX
H

O
F
B 62

U
U
S 4xK
E

R OUT OUT
P
Q
IN

Differential pressure indicator Differential pressure


G øW indication switch
D
C
V (Element removal dimension)

L
M

4xJ
A

(mm)
Model A B C D E F G H I J K L M N O P Q R
FH990-04 1/2B M10 x 1.5 M10 x 1.5
FH990-06
1B
3/4B
150 75 80 164 112 40 40
Thread depth 22 Thread depth 22
52.4 26.2 22.2 47.6 16.5 6 16.5 FH
FH990-08 1B M12 x 1.75 M12 x 1.75
FH990-10
1 1/2 B
1 1/4B
200 110 95 186 126 50 70
Thread depth 23 Thread depth 23
69.9 35.7 30.2 58.7 16.5 8 16.5 HOW
FH990-12 1 1/2B M12 x 1.75 M12 x 1.75
2B 250 140 115 218 150 60 90 77.8 42.9 42.9 77.8 21.5 10 21.5
FH990-16 2B Thread depth 23 Thread depth 23
FH991-20 2 1/2B M16 x 2 M16 x 2
300 170 150 268 180 80 120 106.4 61.9 61.9 106.4 21.5 10 21.5
FH991-24 3B Thread depth 34 Thread depth 34
FH991-28 3 1/2B M16 x 2 M16 x 2
280 145 140 273 210 80 120 130 78 78 130 20 5 20
FH991-32 4B Thread depth 30 Thread depth 30

Mass (kg)
Model S T U V W X Threaded
With flange
without flange
FH990-04 M8 x 1.25 23
6 84 180 35 2.4 3.4
FH990-06 Thread depth 8 28
FH990-08 M8 x 1.25 35
8 91 240 50 3.6 5.0
FH990-10 Thread depth 8 44
FH990-12 M8 x 1.25 50
10 103 300 62 5.4 7.8
FH990-16 Thread depth 9 62
FH991-20 M10 x 1.5 77
10 118 360 9.7 13.5
FH991-24 Thread depth 12 90
FH991-28 M10 x 1.5 102
5 133 340 10.6 14.4
FH991-32 Thread depth 12 115
Note) Both flange and thread connections are supported. However, only flange types for
FH991-20 to FH991-32 are compatible. The flange configuration is exclusive to SMC.
Tapered thread types (female) conforming to JIS B 0203.
1525
Suction Guard

Series FHG RoHS

Specifications
Designed to prevent collected dust Fluid Hydraulic fluid
from falling into the tank Operating pressure Negative pressure
All collected dust can be disposed complete- Operating temperature Max. 80°C
ly when the element is replaced. There is no Top flange Steel plate
danger of collected matter dropping back Case Steel plate
into the tank. Main material Inlet pipe Steel plate
No need to replace flushing oil O-ring NBR or FKM Note)
Since all dust is eliminated during trial opera- Seal NBR or EPDM Note)
tion, it is not necessary to replace flushing Material Micromesh
oil. This reduces both labor and wasted oil. Element Nominal filtration 74, 105, 149 µm (200, 150, 100 mesh)
Easy maintenance and no air mixing Differential pressure resistance 0.2 MPa
Differential pressure indicator operating pressure 24.0 kPa
No special tools are required for mainte-
Air breather nominal filtration 40 µm
nance, and insertion-type element replace-
ment is quick and easy. This helps prevent Lubrication port strainer nominal filtration 10 mesh or equivalent
air mixture into the suction line and pump Note) The material of the O-rings and seals differs depending on the hydraulic fluid used.
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM
damage.
Compact tank equipment Connection Model/Rated Flow Rate
The lubrication port strainer, suction filter, Companion flange, Rated
and air breather are all integrated into a Female threaded companion flange, Model Port size flow rate
L-block companion flange, (L/min)
single unit, reducing the volume of equip-
L-block female threaded companion flange, FHG9A-M-04 1/2B 18
ment around the tank. S-block companion flange,
FHG9A-M-06 3/4B 32
Selection of connection methods and S-block female threaded companion flange
FHG9A-M-08 1B
53
accessories for a variety of applica- Note 1) Female threaded connection ports are 1/2B
to 2B only. FHG9B-M-10 1 1/4B 90
tions FHG9B-M-12 1 1/2B 120
Note 2) Flange configuration is exclusive to SMC.
Six methods are available as standard. Dif- FHG9B-M-16 2B 200
ferential pressure indicators (visual and FHG9C-M-20 2 1/2B 315
switch) are available and can be selected to
FHG9C-M-24 3B 450
match the application.
Accessory/Option
Description Part no. Note
CB-21H Petroleum, Water-glycol, Emulsion
Differential pressure indicator
CB-21H-V Phosphoric ester
Differential pressure indication switch CB-67H Petroleum, Water-glycol, Emulsion
(N.C. and N.O. common) CB-67H-V Phosphoric ester
CW-4H Petroleum
CW-4H-W For 1/2B to 1B Water-glycol, Emulsion
CW-4H-V Phosphoric ester
CW-5H Petroleum
Air breather CW-5H-W For 1 1/4B to 2B Water-glycol, Emulsion
CW-5H-V Phosphoric ester
CW-6H Petroleum
PAT. PEND CW-6H-W For 2 1/2 , 3B B Water-glycol, Emulsion
CW-6H-V Phosphoric ester
D-73H Petroleum
D-73H-W For 1/2B to 1B Water-glycol, Emulsion
D-73H-V Phosphoric ester
D-74H Petroleum
Cap D-74H-W For 1 1/4B to 2B Water-glycol, Emulsion
D-74H-V Phosphoric ester
D-75H Petroleum
D-75H-W For 2 1/2B, 3B Water-glycol, Emulsion
D-75H-V Phosphoric ester

1526
Suction Guard Series FHG

How to Order

FH G 9 0 A M 074 04 0 0
Hydraulic filter Made to Order
Port size Nil None (Standard)
Suction guard 04 1/2B X0 Non-standard filtration
Rated pressure 06 3/4B Note) Refer to page 1548 for details.
08 1B
9 Negative pressure
10 1 1/4B
12 1 1/2B Air breather
Hydraulic fluid
16 2B Nil Air breather
0 Petroleum
20 2 1/2B C Cap
1 Water-glycol, Emulsion
24 3B
2 Phosphoric ester
Connection
Port size category Nominal filtration 0 Companion flange
074 74 µm 1 Female threaded companion flange
A 1/2B, 3/4B, 1B
105 105 µm 2 L-block companion flange
B 1 1/4B, 1 1/2B, 2B
149 149 µm 3 L-block female threaded companion flange
C 2 1/2B, 3B
4 S-block companion flange
Length below flange neck (T dimension) Element 5 S-block female threaded companion flange
M Micromesh
Port size
Standard T dimension T dimension Differential pressure indication
(Nominal size) Symbol Length Adjustment range when shipped 0 None
(mm) (mm) (Max. T dimension)
1 Differential pressure indicator
1 310 340
5 Differential pressure indication switch Note)
04 (1/2B) 2 380 410
Note) N.C. and N.O. common
06 (3/4B) 3 450 ±30 480
08 (1 )
B 4 520 550
5 590 620
1 385 430
10 1/4
(1 B ) 2 485 530
12 (1 1/2B) ±45
3 585 630
16 (2B)
4 685 730
1 560 560
20 (2 1/2B) 2 650 650
Fixed
24 (3 )
B 3 750 750
4 850 850

Replacement Element Part No. (Including O-ring for element)


74 µm 105 µm 149 µm
Port size (Nominal size) Element size
(200 mesh) (150 mesh) (100 mesh)
04 (1/2B), 06 (3/4B), 08 (1B)
10 (1 1/4B), 12 (1 1/2B), 16 (2B)
EM220-074N
EM320-074N
EM220-105N
EM320-105N
EM220-149N
EM320-149N
ø70 x 90
ø90 x 125
FH
20 (2 1/2B), 24 (3B) EM420-074N EM420-105N EM420-149N ø110 x 190
Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type. HOW
N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion.
Note 2) Refer to page 1548 for non-standard filtration.
Note 3) Above elements require one element per filter.

Construction/Seal List
Replacement O-ring/Seal List (One each of the seal and
Differential pressure O-ring types listed below are required per filter.)
indicator w O-ring e O-ring
Air breather t Port q Seal r Seal t Seal
Material order no. order no.
(cap) r Seal size order no. order no. order no.
(Nominal size) (Nominal size)
q Seat seal KA00463 KA00080
06 to 08 AL-180H AL-183H AL-162H
Lubrication port strainer (1A-G65) (1A-P34)
KA00793 KA00808
10 to 16 NBR AL-181H AL-184H AL-163H
(1A-G85) (1A-P60)
Hexagon nut KA00065
e Suction pipe 20 to 24 AL-182H — AL-185H AL-164H
(1A-G95)
Tension bolt
KA00614 KA00105
06 to 08 AL-180H-V AL-183H-V AL-162H-V
(4D-G65) (4D-P34)
FKM
Element opening KA00703 KA00733
Band
10 to 16 or AL-181H-V AL-184H-V AL-163H-V
(4D-G85) (4D-P60)
Element w EPDM
KA00705
20 to 24 AL-182H-V — AL-185H-V AL-164H-V
Case (4D-G95)
Note) The material of seals (AL-162H-V to AL-164H-V and AL-180H-V to AL-
182H-V) is EPDM.
1527
Series FHG

Flow Characteristics
Differential Pressure Indication Handling Precautions
Series FHG
 Differential pressure indication switch w Operation
• When
Operating pressure—24 kPa
• Operation of the differential pressure indicator
• automatically
a value has been displayed, it will be
reset when the pump is
in cold weather such as during winter mostly
10 occurs due to high viscosity, so check wheth-
stopped. (Non-reset type) er it is from clogging or not after normal op-
• The element should be replaced when the eration stars.
Pressure drop (kPa)

switch is actuated.
• N.C. and N.O. common • Once the differential pressure indicator is trig-
gered, the indication continues to be dis-
/08

/16

played until the indicator is reset (by depress-


/24
/06

/12

ing the reset button), even if the pump stops


-20
-10
-04

COM. operating.
N.O. Reset after replacing the element and restart-
N.C. ing operation, or after normal operation starts
in cold weather such as during winter.

G1/2
• When using a differential pressure indication
switch and if a filter clogged signal is incorpo-
1
rated into the sequence circuit of the ma-
10 100 1000
chine, make sure to design the system so the
Flow rate (L/min) filter clogged signal does not operate until
Conditions Fluid: Turbine oil Class 2 VG32 normal operation starts.
Viscosity: 45 mm2/s
Filter material: Micromesh
e Element replacement
Nominal filtration: 74 µm
∗ Refer to page 1549 for “Microswitch for differ-
• When the pressure difference reaches 24 kPa
during filter operation (triggering the differen-
ential pressure indication switch”. tial pressure indicator), stop operation and ei-
ther wash or replace the element.
• When replacing the element, check the O-
rings and replace them if they are damaged.
• not scratch or damage
When installing and removing an element, do
it by touching the cor-
ners of the case, etc.
• When washing the element, do not wipe it us-
ing a stiff brush or rag.

r Removing the element


• turn
Rotate the air breather (cap) one-third of a
counterclockwise and remove it. Grasp
the handle of the lubrication port strainer in-
side and, while rotating it clockwise, pull it up
vertically. The suction element is screwed onto
one end of the tension bolt and along with the
lubrication port strainer, can be removed and
installed freely. Do not remove the suction ele-
ment while the pump is operating.

Differential Pressure Indication Handling Precautions t T dimension (length below flange


neck) adjustment
Two indication methods are available: differen- q Mounting
• The product is shipped from the factory with
tial pressure indicator and differential pressure
indication switch. These can be mounted on all • The portion of the suction guard below the oil
tank mounting flange is installed inside the oil
the maximum T dimension, so the user must
adjust it to the required T dimension.
filter models.
Direct mounting is possible if the connection
tank, so check to make sure it is clean when
mounting it. For maintenance, make sure to
• The T dimension adjustment range, relative
to the standard T dimension, is ±30 mm for
method is L-block or S-block. Otherwise, an provide sufficient space above the filter for re- 1/2B to 1B and ±45 mm for 1 1/4B to 2B. The
Rc1 female thread fitting is required. moving the element. dimension for 2 1/2B to 3B is fixed, so no ad-
In addition, if no differential pressure indication
is required, use a commercially available plug • Use caution to ensure airtightness when con- justment is possible.
(R1).
necting an outlet and installing a differential
pressure indicator (especially for the thread
• Refer to the operating manual for details of
the adjustment method.
 Differential pressure indicator type).
• Once
Operating pressure—24 kPa • Ensure that the oil tank fluid volume (minimum y Lubrication
• be displayed
a value is displayed, it will continue to
until reset, even if the pump is
fluid level MIN(r) dimension) is 30 mm for 1/2B
to 1B, 60 mm for 1 1/4B to
• Remove the air breather (cap) and lubricate
through the lubricatioin port strainer. Be care-
stopped. (Reset type) 1 1/2B, 80 mm for 2B, and 120 mm or more for ful not to let oil, etc., get onto the cap while it is
• The element should be replaced when the
red indication is visible.
2 1/2B to 3B, measured when there is no turbu-
lence in the flow from the element opening or
being removed.

fluctuation in the fluid level. Also, select a T di-


mension (length below flange neck) that will
Reset button ensure that the fluid level does not reach the
lubrication port strainer.

1528
Suction Guard Series FHG

Dimensions
A A
Port size: 04 to 16 10 Element removal dimension T+100 I 4 x ø10 Port size: 20, 24 10 135 170 6 x ø10

Element removal dimension T+100


10

10
B
H

B
H
L L

M
C D
M

Cap C D Cap
Air breather Air breather

(65)
(U)
(S)

(65)
(S)

(U)
F

F
Seat seal
Seat seal
IDøG
AG

IDøG

AG
Lubrication port strainer Lubrication port strainer

Minimum 4 x M8 6 x M8
fluid level Minimum
I fluid level 135 170
T

T
MIN (r)

MIN (r)
AC AC
Window
H

AD

Window

AD
for removal for removal
(V)

(V)
Body mounting dimension Body mounting dimension
Element Element
(mm)
Port size Standard T dimension T dimension
(Nominal size)
A B C D F G H I L M S U V r AC AD AG
1 2 3 4 5 adjustment range
1/2B (04) 215 130 65 90 6 72 110 195 19 10 63 14 90 30 177 110 120
3/4B (06) 215 130 65 90 6 72 110 195 19 10 63 14 90 30 177 110 120 310 380 450 520 590 ±30
1B (08) 215 130 65 90 6 72 110 195 19 10 63 14 90 30 177 110 120
1 1/4B (10) 265 150 75 115 6 86 130 245 19 10 63 17 126 60 227 130 140
1 1/2B (12) 265 150 75 115 6 86 130 245 19 10 63 17 126 60 227 130 140 385 485 585 685 — ±45
2B (16) 265 150 75 115 6 86 130 245 19 10 63 17 126 80 227 130 140
2 1/2B (20) 325 190 85 145 8 106 170 — 20 20 76 17 197 120 285 150 170
560 650 750 850 — Fixed
3B (24) 325 190 85 145 8 106 170 — 20 20 76 17 197 120 285 150 170

Connection part dimensions/ Female threaded companion flange L-type block companion flange
Companion flange Differential pressure
indication switch
ød
Differential
ød
(75)

pressure
(50)

E (Rc) indicator
L-type block
FH
Y

P
Z
G

Y
(mm) (mm) N
(mm)
HOW
Port size d G Y Weight (kg)∗ Port size E Z Weight (kg)∗ Port size d N P Q Y Weight (kg)∗
1/2B (04) 22.2 25 9 2.7 1/2B (04) 1/2 47 2.8 1/2B (04) 22.2 56 71 53 9 3.6
3/4B (06) 27.7 25 9 2.7 3/4B (06) 3/4 47 2.8 3/4B (06) 27.7 56 71 53 9 3.6
1B (08) 34.5 25 9 2.7 1B (08) 1 52 2.8 1B (08) 34.5 56 71 53 9 3.6
1 1/4B (10) 43.9 28 9 5.1 1 1/4B (10) 1 1/4 58 5.3 1 1/4 B (10)
43.9 76 104 74 9 7.3
B (12) B (12)
1 1/2 49.1 28 9 5.1 1 1/2 1 1/2 58 5.3 1 1/2 B (12)
49.1 76 104 74 9 7.3
B (16) B (16)
2 61.1 28 9 5.0 2 2 63 5.4 2B (16) 61.1 76 104 74 9 7.1
2 1/2B (20) 77.1 28 9 10.3 ∗ Weight values are for the minimum T dimension (symbol 1) in each standard T dimension. 2 1/2B (20) 77.1 101 129 94 9 14.5
3B (24) 90.0 28 9 10.3 3 B (24)
90.0 101 129 94 9 14.5
∗ Weight values are for the minimum T dimension (symbol 1) in each standard T dimension. ∗ Weight values are for the minimum T dimension (symbol 1) in each standard T dimension.
S-type block companion flange ∗ The “OUT” direction can be mounted up to 90° to the left or right.

L-type block female threaded companion flange S-type block female threaded companion flange
Differential pressure
indication switch ød Differential pressure
Differential pressure S-type block indication switch
indicator Differential pressure
Y

E (Rc) S-type block


(75)

AE

indication switch
(50)

E (Rc) Differential pressure


K

indicator Differential pressure


L-type block
(50)
W
R

(75) indicator
P

(mm)
(50)
J Port size d K W Y AE Weight (kg)∗ W (75)
1/2B (04) 22.2 47 70 9 62 3.5 (mm)
Port size E J P Q Weight (kg)∗ 3/4B (06) 27.7 47 70 9 62 3.5 Port size E R W Weight (kg)∗
1/2B (04) 1/2 78 71 53 3.7 1 B (08)
34.5 47 70 9 62 3.5 1/2B (04) 1/2 69 70 3.6
3/4B (06) 3/4 78 71 53 3.7 1 1/4B (10) 43.9 50 85 9 65 6.2 3/4B (06) 3/4 69 70 3.6
1B (08) 1 83 71 53 3.7 1 1/2B (12) 49.1 50 85 9 65 6.2 1B (08) 1 74 70 3.6
1 1/4B (10) 1 1/4 106 104 74 7.4 2B (16) 61.1 50 85 9 65 6.1 1 1/4B (10) 1 1/4 80 85 6.4
B (12) B (20) B (12)
1 1/2 1 1/2 106 104 74 7.4 2 1/2 77.1 50 105 9 65 11.9 1 1/2 1 1/2 80 85 6.4
2B (16) 2 111 104 74 7.5 3B (24) 90.0 50 105 9 65 11.9 2B (16) 2 85 85 6.5
∗ Weight values are for the minimum T dimension (symbol 1) in each standard T dimension. ∗ Weight values are for the minimum T dimension (symbol 1) in each standard T dimension. ∗ Weight values are for the minimum T dimension (symbol 1) in each standard T dimension.
∗ The “OUT” direction can be mounted up to 90° to the left or right. ∗ The differential pressure indication entry can be mounted up to 90° to the left or right. ∗ The differential pressure indication entry can be mounted up to 90° to the left or right.

1529
Line Filter

Series FH34/44/54/64
Rated Pressure: 3.5, 7, 14, 21 MPa RoHS

Specifications
Compact, solid, and safe design Fluid Hydraulic fluid
The case and cover have undergone testing Operating pressure Max. 3.5 MPa Max. 7, 14, 21 MPa
in which they were subjected 100,000 times Operating temperature Max. 80°C
to impacts equivalent 1.5 times the rated Aluminum die-cast (3/8, 1/2, 3/4, 1)
Cover/Case Cast iron
pressure (confirming to MIL standard). Main material Aluminum casted (1 1/4, 1 1/2, 2)
Easy element replacement O-ring NBR or FKM Note)
The element is extracted from the top, and Material Paper
secured in place by inserting an O-ring seal. Element Nominal filtration 5, 10, 20 µm
The element can be installed and removed Differential pressure resistance 0.6 MPa
easily, simplifying maintenance. Differential pressure indicator operating pressure 0.275 MPa
Reliable outlet side Relief valve open pressure 0.35 MPa
Note) The material of the O-rings and seals differs depending on the hydraulic fluid used. Petroleum, Water-glycol,
A firm seal is secured through a special con- Emulsion: NBR; Phosphoric ester: FKM
figuration combining a pressure clamp from
an O-ring around the inner perimeter of the Model/Rated Flow Rate
case with support from the cover, and there Operating Model Port size Rated Operating Model Port size Rated
pressure flow rate pressure flow rate
is no resistance when the cover is installed Threaded
connection Flange connection Threaded
Rc Flange SSA (L/min) Threaded
connection Flange connection Threaded
Rc Flange SSA (L/min)
and removed. FH340-03 — 3/8 — 10 FH540-03 — 3/8 — 10
Large drain exhaust port FH340-04 — 1/2 — 20 FH540-04 FH541-04 1/2 15 (1/2B) 20
The large M24 drain exhaust port assures Max. FH342-06 FH341-06 3/4 20 (3/4B)
50 Max. FH540-06 FH541-06 3/4 20 (3/4B) 50
rapid drainage. 3.5 FH342-08 FH341-08 1 25 (1B) 80 14 FH540-08 FH541-08 1 25 (1B) 80
MPa FH340-10 FH341-10 1 1/4 32 (1 1/4B) 120 MPa FH540-10 FH541-10 1 1/4 32 (1 1/4B) 120
Easy fluid flow direction reversal
FH340-12 FH341-12 1 1/2 40 (1 1/2B) 160 FH540-12 FH541-12 1 1/2 40 (1 1/2B) 160
Simply turn the cover 180° relative to the
case mounting base to reverse the fluid flow — FH341-16 — 50 (2B) 260 — FH541-16 — 50 (2B) 260
direction. FH440-03 — 3/8 — 10 FH640-03 — 3/8 — 10
FH440-04 FH441-04 1/2 15 (1/2B) 20 FH640-04 FH641-04 1/2 15 (1/2B) 20
Clogging sensor
FH440-06 FH441-06 3/4 20 (3/4B) 50 Max. FH640-06 FH641-06 3/4 20 (3/4B) 50
The filter can be mounted with a differential
Max. FH440-08 FH441-08 1 25 (1B) 80 21 FH640-08 FH641-08 1 25 (1B) 80
pressure indicator (reset type) or differential MPa FH640-10
7 FH440-10 FH441-10 1 1/4 32 (1 1/4B) 120 FH641-10 1 1/4 32 (1 1/4B) 120
pressure indication switch (common with vi- MPa FH440-12 FH441-12 1 1/2 40 (1 1/2B) 160 FH640-12 FH641-12 1 1/2 40 (1 1/2B) 160
sual, non-reset type).
— FH441-16 — 50 (2B) 260 — FH641-16 — 50 (2B) 260
— FH441-20 — 65 (2 1/2B) 450
— FH441-24 — 80 (3B) 600
Note) Tapered female thread connection conforming to JIS B 0203 is compatible.
Flanges conforming to JIS B 2291 (21 MPa piping flanges for hydraulic use) SSA are compatible.

Accessory/Option
Description Part no. Model Note
CB-48H FH34 01 Petroleum, Water-glycol, Emulsion
to
CB-48H-V FH44 0
1 Phosphoric ester
Differential pressure CB-52H Petroleum, Water-glycol, Emulsion
indicator FH342
CB-52H-V Phosphoric ester
CB-64H FH54 01 Petroleum, Water-glycol, Emulsion
to
CB-64H-V FH64 0
1 Phosphoric ester
CB-49H FH34 0
1 Petroleum, Water-glycol, Emulsion
to
CB-49H-V FH44 0
1 Phosphoric ester
Differential pressure
CB-53H Petroleum, Water-glycol, Emulsion
indication switch FH342
(N.C. and N.O. common) CB-53H-V Phosphoric ester
CB-65H FH54 01 Petroleum, Water-glycol, Emulsion
to
CB-65H-V FH64 0
1 Phosphoric ester
AG-9H Petroleum
FH34 01
AG-9H-W to Water-glycol, Emulsion
Blanking cap FH64 01
AG-9H-V Phosphoric ester
(for differential pressure
indication part) AG-12H Petroleum
AG-12H-W FH342 Water-glycol, Emulsion
AG-12H-V Phosphoric ester
1530
Line Filter Series FH34/44/54/64

How to Order

FH 3 40 03 0 0 0 P 005 L
Made to Order
Hydraulic filter
Nil None (Standard)
Operating pressure (Max.) X0 Micromesh element equipped
3 3.5 MPa Note) Refer to page 1548 for
4 7 MPa Differential pressure details.
5 14 MPa indication Nominal
6 21 MPa 0 None filtration
1 Differential pressure indicator 005 5 µm Fluid direction
Construction/Connection 2 Differential pressure indication switch Note) 010 10 µm Nil IN left
40 Element upward 4 Differential pressure indicator 020 20 µm L IN right
Threaded
42∗ removal 5 Differential pressure indication switch Note) Note) For water-glycol or
Element upward Note) N.C. and N.O. common emulsion: only 10 µm.
41 removal Flange
Construction 42 only Element
∗ Indicates 42 for 3.5 MPa, Port Relief valve Hydraulic fluid P Paper
sizes 3/4 and 1.
Port size 0 With relief valve 0 Petroleum M Micromesh
Symbol Threaded Rc Flange SSA 1 None 1 Water-glycol, Emulsion

03 3/8 — 2 Phosphoric ester

04 1/2 15 (1/2B) Replacement Element Part No. (Including O-ring for element)
06 3/4 20 (3/4 B)
Port size 5 µm 10 µm 20 µm Element size
08 1 25 (1B) 03 (3/8), 04 (1/2) EP910-005N EP910-010N EP910-020N ø53 x 90
10 1 1/4 32 (1 1/4B) 06 (3/4), 08 (1) EP020-005N EP020-010N EP020-020N ø74 x 117
12 1 1/2 40 (1 1/2B) 10 (1 1/4), 12 (1 1/2) EP120-005N EP120-010N EP120-020N ø74 x 195
16 — 50 (2B) 16 (2) EP220-005N EP220-010N EP220-020N ø88 x 282
20 — 65 (2 1/2B) 20 (2 1/2), 24 (3) EP820-005N EP820-010N EP820-020N ø119 x 280
24 — 80 (3B) Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type.
Note) For selection from thread and N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion (10 µm only)
flange, refer to “Model/Rated Note 2) Refer to page 1548 for micromesh elements.
Flow Rate” on page 1530. Note 3) Above elements require one element per filter.

Construction/Seal List

Replacement O-ring/Seal List (One each of the seal


Differential pressure
and O-ring types listed below are required per filter.)
indication switch Applicable q O-ring w O-ring e O-ring r O-ring
Port
Model hydraulic Material order no. order no. order no. order no.
size
fluid (Nominal size) (Nominal size) (Nominal size) (Nominal size)
KA00465 KA00471 KA00468
FH340 03 to 04
Differential
(1B-G80)
KA00453
(1A-P30)
KA00082
(1A-P22A)
KA00079
FH
pressure FH34∗ 06 to 08
Hexagon socket (1B-G105) (1A-P44) (1A-P32) KA00470
head cap screw Blanking cap
indicator
KA00463 KA00471 KA00074 HOW
FH44∗ to 64∗ 03 to 04
(1B-G65) (1A-P30) (1A-P20)
Petroleum,
Cover KA00079
e O-ring
FH44∗ to 64∗ 06 to 08 Water-glycol, NBR KA00466 KA00082
(1A-P32)
Emulsion
q O-ring KA00803
FH34∗ to 64∗ 10 to 12 (1B-G90) (1A-P44)
OUT (1A-P40)
IN KA00453 KA00806 KA00806 (P28)
FH341 to 641 16
w O-ring (1B-G105) (1A-P50) (1A-P50)
Relief valve KA00060 KA00809 KA00809
FH441 20 to 24
(1B-G145) (1A-P85) (1A-P85)
Element
KA01296M KA00104 KA00713
Differential pressure FH340 03 to 04
(G80·Hs90) (4D-P30) (4D-P22A)
Case indicator KA02476 KA00107 KA00720
FH34∗ 06 to 08
(G105·Hs90) (4D-P44) (4D-P32) KA00717
KA01759 KA00104 KA00102
FH44∗ to 64∗ 03 to 04
(G65·Hs90) (4D-P30) (4D-P20)
r O-ring
Phosphoric KA00720
FH44∗ to 64∗ 06 to 08 FKM KA01296 KA00107
Drain plug ester (4D-P32)
KA00722
FH34∗ to 64∗ 10 to 12 (G90·Hs90) (4D-P44)
(4D-P40)
KA02476 KA00636 KA00636 (P28)
DRAIN FH341 to 641 16
(G105·Hs90) (4D-P50) (4D-P50)
KA01760 KA00725 KA00725
FH441 20 to 24
(G145·Hs90) (4D-P85) (4D-P85)

1531
Series FH34/44/54/64

Flow Characteristics
Differential Pressure Indication Handling Precautions
Series FH34/44
Two indication methods are available: differen- q Mounting
0.15 tial pressure indicator and differential pressure
indication switch. These can be mounted on all
• Confirm INLET and OUTLET before mount-
ing. Then connect so that the drain is oriented
0.1 filter models. downward. For maintenance, make sure to
 Differential pressure indicator provide sufficient space above the filter for re-
16
24
Pressure drop (MPa)

20/ • Once
Operating pressure—0.275 MPa moving the element.
0.05
0.04
• be displayed
a value is displayed, it will continue to
until reset, even if the pump is
w Operation
08

• Operation
12

0.03 stopped. (Reset type) of the differential pressure indicator


06/

10/

0.02
• Perform element replacement when the red
ring floats up and covers the entire view port.
in cold weather such as during winter mostly
occurs due to high viscosity, so check wheth-
er it is from clogging or not after normal op-
04

eration starts.
03/

0.01 Reset button • Once the differential pressure indicator is ac-


tuated, the indication continues to be dis-
View port played until the indicator is reset (by depress-
ing the reset button), even if the pump stops
10 30 50 100 300 500 operating.
Flow rate (L/min) Reset after replacing the element and restart-
ing operation, or after normal operation starts
Conditions Fluid: Turbine oil Class 2 VG56
Measured pressure: 3.5, 7 MPa in cold weather such as during winter.
Viscosity: 45 mm2/s • When using a differential pressure indication
switch and if a filter clogged signal is incorpo-
Filter material: Paper
Nominal filtration: 10 µm rated into the sequence circuit of the ma-
chine, make sure to design the system so the
Series FH54  Differential pressure indication switch filter clogged signal does not operate until
• When
Operating pressure—0.275 MPa normal operation starts.
0.1
• automatically
a value has been displayed, it will be
reset when the pump is
e Element replacement
• When
16

the pressure difference reaches 0.275


stopped. (Non-reset type)
MPa during operation (actuating the differen-
0.05
• This is a visual dual-purpose. Perform ele-
/12

tial pressure indicator), stop operation, drain


Pressure drop (MPa)

0.04
ment replacement when the switch has actu-
10

the oil from the case, and replace the element.


/08

0.03 ated (when the red ring floats up and covers


• When replacing the element, check the O-
06

the entire view port).


rings and replace them if they are damaged.
0.02
• N.C. and N.O. common
• When installing and removing an element, do
not scratch or damage it by touching the cor-
0.01 ners of the case, etc.
04

COM.
r Others
03/

N.O.
N.C.
• hardness
For the top cover O-ring, use a product of
90 to prevent leaks or damage.
View port G1/2 • onthere
If is back pressure, install a check valve
the outlet side to prevent damage to the
5 10 30 50 100 300
element.
Flow rate (L/min)
Conditions Fluid: Turbine oil Class 2 VG56
• Turn the top cover 180° to reverse the oil flow
direction.
Measured pressure: 14 MPa
Viscosity: 45 mm2/s
• force evenly
Use an auxiliary pipe or the like and apply
when tightening the cap screws
Filter material: Paper on the cover and case.
Nominal filtration: 10 µm

Series FH64
∗ Refer to page 1549 for “Microswitch for differ-
0.1 ential pressure indication switch”.
16
/12

0.05
10
/08
Pressure drop (MPa)

0.04
06

0.03

0.02
/04
03

0.01

0.005

0.003

5 10 30 50 100 300
Flow rate (L/min)
Conditions Fluid: Turbine oil Class 2 VG56
Measured pressure: 21 MPa
Viscosity: 45 mm2/s
Filter material: Paper
Nominal filtration: 10 µm
1532
Line Filter Series FH34/44/54/64

Dimensions
Comparison flange base Companion Flange Bolt Dimensions
D øM (Drill) Port Flange O-ring
Model Bolt dimension
size (JIS B2291) (JIS B240-1-A)
C

FH441
M10 x 1.5 x 30

P
04 FH541 SSA15 G25
B

Differential FH641 M10 x 1.5 x 40


pressure
4 x N depth Q indication switch
FH341
A FH441 M10 x 1.5 x 30
06 SSA20 G30
FH541
F (Element removal dimension)

Differential pressure FH641 M10 x 1.5 x 40

(65∗)
(60)
indicator FH341

(34∗)
(30)
Blanking cap FH441 M12 x 1.75 x 40
08 SSA25 G35
FH541
FH641 M12 x 1.75 x 45
2xd
G

FH341
G

G
FH441 M12 x 1.75 x 40
IN OUT IN OUT IN OUT 10 SSA32 G40
FH541
X X'
FH641 M12 x 1.75 x 45
Differential pressure Differential pressure
FH341
indicator indication switch
FH441 M16 x 2 x 50
H

Bracket mounting base 12 SSA40 G50


FH541
Bracket mounting base port size 10 to 24
D FH641 M16 x 2 x 60
E

port size 03 to 08
FH341
D FH441 M16 x 2 x 50
J J'

X X' X X'
16 SSA50 G60
FH541
J

FH641 M16 x 2 x 60
2 x K depth L 20 FH441 M20 x 2.5 x 65 SSA65 G75
4 x K depth L
24 FH441 M22 x 2.5 x 65 SSA80 G85
DRAIN
Note 1) The companion flange mounting base conforms to
JIS B 2291 (21 MPa pipe flanges for hydraulic use)
SSA.
Note 2) This filter does not include any companion flange,
companion flange bolt, and O-ring.
(∗): Internal dimensions for FH342 type
(mm)

Model
d A B C D E F G H J J' K L M N P Q
Weight
Threaded Rc Flange SSA (kg)
FH340-03 3/8 —
105 96 50 80 160.5 275 57 217.5 5 — 2 x M8 x 1.25 19 — — — — 1.8
FH340-04 1/2 —
FH342-06 3/4 —
136 120 65 60 180 340 61 241 0 — 2 x M10 x 1.5 15 — — — — 2.5
FH342-08 1 —
FH341-06 — 20 (3/4B) 20 4 x M10 x 1.5 40 12
FH341-08 — 25 (1B)
141 120 63 100 199.5 330 69 268.5 0 — 2 x M10 x 1.5 23
25 4 x M12 x 1.75 48 17
3.5
FH
FH34 01 -10 1 1/4 32 (1 1/4B) 32 4 x M12 x 1.75 56 17
150 106 56 100 260 435 87 347 50 0 4 x M10 x 1.5 23 4.6
FH34 01 -12 1 1/2 40 (1 1/2B) 36 4 x M16 x 2 65 20 HOW
FH341-16 — 50 (2B) 155 120 70 120 361 545 94 455 60 0 4 x M12 x 1.75 28 46 4 x M16 x 2 73 20 6.4
FH440-03 3/8 — — — — —
100 80 45 60 152 285 62 214 0 — 2 x M8 x 1.25 14 4.5
FH44 01 -04 1/2 15 (1/2B) 16 4 x M10 x 1.5 36 12
FH44 01 -06 3/4 20 (3/4B) 20 4 x M10 x 1.5 40 12
135 108 57 80 182 330 73 255 0 — 2 x M10 x 1.5 18 8.7
FH44 01 -08 1 25 (1B) 25 4 x M12 x 1.75 48 17
FH44 01 -10 1 1/4 32 (1 1/4B) 32 4 x M12 x 1.75 56 17
150 105 57 80 260 435 87 347 50 0 4 x M10 x 1.5 18 12.2
FH44 01 -12 1 1/2 40 (1 1/2B) 36 4 x M16 x 2 65 20
FH441-16 — 50 (2B) 160 120 65 92 359 540 94 453 60 0 4 x M12 x 1.75 22 46 4 x M16 x 2 73 20 18.1
FH441-20 — 65 (2 1/2B) 60 4 x M20 x 2.5 92 27
220 170 100 130 390 615 119 509 40 25 4 x M12 x 1.75 22 35.9
FH441-24 — 80 (3B) 70 4 x M22 x 2.5 103 27
FH540-03 3/8 — — — — —
105 86 45 70 152 285 62 214 0 — 2 x M8 x 1.25 14 5.2
FH54 01 -04 1/2 15 (1/2B) 16 4 x M10 x 1.5 36 12
FH54 01 -06 3/4 20 (3/4B) 20 4 x M10 x 1.5 40 12
145 108 56 100 182 330 73 255 0 — 2 x M10 x 1.5 18 9.7
FH54 01 -08 1 25 (1B) 25 4 x M12 x 1.75 48 17
FH54 01 -10 1 1/4 32 (1 1/4B) 32 4 x M12 x 1.75 56 17
150 108 56 100 260 435 87 347 50 0 4 x M12 x 1.75 22 12.8
FH54 01 -12 1 1/2 40 (1 1/2B) 36 4 x M16 x 2 65 20
FH541-16 — 50 (2B) 180 126 70 120 361 545 94 455 60 0 4 x M12 x 1.75 22 46 4 x M16 x 2 73 20 20.4
FH640-03 3/8 — — — — —
120 98 51 90 152 285 62 214 0 — 2 x M10 x 1.5 18 6.9
FH64 01 -04 1/2 15 (1/2B) 16 4 x M10 x 1.5 36 22
FH64 01 -06 3/4 20 (3/4B) 20 4 x M10 x 1.5 40 22
155 124 65 120 182 330 73 255 0 — 2 x M10 x 1.5 18 12.9
FH64 01 -08 1 25 (1B) 25 4 x M12 x 1.75 48 22
FH64 01 -10 1 1/4 32 (1 1/4B) 32 4 x M12 x 1.75 56 22
180 124 65 125 260 435 87 347 50 0 4 x M12 x 1.75 22 19.8
FH64 01 -12 1 1/2 40 (1 1/2B) 36 4 x M16 x 2 65 30
FH641-16 — 50 (2B) 200 144 75 145 361 545 94 455 60 0 4 x M12 x 1.75 22 46 4 x M16 x 2 73 30 29
Note) Tapered female thread conforming to JIS B 0203 is compatible.
Flanges conforming to JIS B 2291 (21 MPa pipe flanges for hydraulic use) SSA are compatible.
1533
Vertical Return Filter

Series FHBA RoHS

Specifications
The vertical return filters are designed Operating pressure Max. 1.6 MPa
for mounting directly on top of oil Operating temperature Max. 80°C
tanks for hydraulic systems. They Cover Aluminum die-cast
prevent dust generated within the Body Aluminum die-cast
Main material
circuit from entering the tank and Case Steel plate
O-ring/Seal NBR or FKM Note)
help keep the oil clean. This efficient
Material Paper and micromesh
configuration reduces the total
Element Nominal filtration ∗ 5, 10, 20 µm
number of filters required.
Differential pressure resistance 0.6 MPa
Differential pressure indicator operating pressure 0.18 MPa
Machine
Relief valve open pressure 0.25 MPa
∗ Micromesh elements with other than the standard filtration are available.
∗ The paper elements for water-glycol is 10 µm only.
Pressure Vertical
Note) The material of the O-rings differs depending on the hydraulic fluid used.
control return filter
valve Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM
M
Pump
Model/Rated Flow Rate
Model Port size (Rc) Max. flow rate (L/min) Weight (kg) Applicable hydraulic fluid
Oil tank FHBA-06 3/4 150 1.7 N : Petroleum
W: Water-glycol
FHBA-10 1 1/4 300 3.7 Emulsion
FHBA-12 1 1/2 400 5 V : Phosphoric ester
Compact design that does not clutter The symbol represented by  indicates the type of applicable hydraulic fluid (N, W, V).
the top of the oil tank
Since most of the filter case is inside the oil
Accessory/Option
tank, very little space is occupied on the top of
the tank. Description Part no. Note
CB-58H Petroleum, Water-glycol, Emulsion
No need for an OUTLET pipe Differential pressure indicator
CB-58H-V Phosphoric ester
The filter case also functions as a fluid return
pipe, so there is no need to attach a separate Differential pressure indication switch CB-59H Petroleum, Water-glycol, Emulsion
OUTLET pipe. (N.C. and N.O. common) CB-59H-V Phosphoric ester
AG-12H Petroleum
Easy maintenance Blanking cap
Simply open the cover and extract the element (for differential pressure indication AG-12H-W Water-glycol, Emulsion
from the top of the filter. Replacement is quick part) AG-12H-V Phosphoric ester
and easy.
Designed to prevent collected dust
from falling into the oil tank Flow Characteristics
The collected dust remains inside the element,
0.1
so it cannot flow out when the relief valve is
opened and all collected dust is removed from
the case. 0.05
Pressure drop (MPa)

Two INLET ports 0.03


The filter has two INLET ports, oriented 180°
from each other to provide more flexibility when
12
10
06

routing pipes. 0.01

0.005

0.001
100 30 50 100 300 500
Flow rate (L/min)

Conditions Fluid: Turbine oil Class 2 VG56


Measured pressure: 1.6 MPa
Viscosity: 45 mm2/s
Filter material: Paper
Nominal filtration: 10 µm

1534
Vertical Return Filter Series FHBA

How to Order

FH B A N 06 P 010 M R
Hydraulic filter Made to Order
Nil None (Standard)
Operating pressure X0 Non-standard filtration
B Max. 1.6 MPa Type Nominal
filtration Relief valve Note) for
The non-standard filtration is
micromesh elements
A Vertical
005 5 µm R With relief valve only. Refer to page 1548 for
D None details.
Hydraulic fluid 010 10 µm
N Petroleum Port size (Rc) 020 20 µm Differential pressure indication
W Water-glycol, Emulsion 06 3/4 Element D None (Blanking cap)
V Phosphoric ester 10 1 1/4 P Paper M Differential pressure indicator
12 1 1/2 M Micromesh E Differential pressure indication switch
Replacement Element Part No.
Port size Paper Micromesh
Element size
(Nominal size) 5 µm 10 µm 20 µm 5 µm 10 µm 20 µm
06 (3/4B) EP001H-005N EP001H-010N EP001H-020N EM601H-005N EM601H-010N EM601H-020N ø56 x 180
10 (1 1/4B) EP101H-005N EP101H-010N EP101H-020N EM701H-005N EM701H-010N EM701H-020N ø76 x 190
12 (1 1/2B) EP201H-005N EP201H-010N EP201H-020N EM801H-005N EM801H-010N EM801H-020N ø76 x 290
Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type. N: Petroleum, Phosphoric ester, W: Water-glycol, Emulsion.
Note 2) Refer to page 1548 for non-standard filtration.
Note 3) Above elements require one element per filter.
Handling Precautions
Construction/Seal List q Mounting
• Confirm the IN orientation before mounting. Then
connect so that the case is oriented downward.
For maintenance, make sure to provide sufficient
Hexagon socket space above the filter for removing the element.
Blanking cap
head cap screw
Conical spring washer
• The filter has two IN ports. If one is not used, it
must be covered with a plug or the like.
Cover
q O-ring
2 x Rc port size (Nominal size) • Before mounting the filter on the oil tank, confirm
that r the O-ring (see “Construction”) is installed
Body on the body.

IN
• Ensure that the opening in the case (OUT) is al-
ways below the fluid surface. Air could leak into
IN
the system if the fluid level drops below the out-
w Seal w Seal let opening.
t O-ring w Operation
e O-ring
r O-ring
• cold
Operation of the differential pressure indicator in
weather, such as during winter, mostly oc-
Element (Top plate for oil tank) curs due to high viscosity, so check whether it is FH
from clogging or not after normal operation starts.
Case
• Once the differential pressure indicator is trig-
gered, the indication continues to be displayed HOW
Spring
until the indicator is reset (by depressing the re-
set button), even if the pump stops operating.
Guide
Reset after replacing the element and restarting
operation, or after normal operation starts in cold
weather such as during winter.
OUT
• When using a differential pressure indication
switch and if a filter clogged signal is incorpo-
rated into the sequence circuit of the machine,
make sure to design the system so the filter
When actuating relief valve clogged signal does not operate until normal op-
eration starts.

Replacement O-ring/Seal List (One each of the seal and O-ring types listed e Element replacement
below are required per filter.) • When the pressure difference reaches 0.18 MPa
during filter operation (actuating the differential
q O-ring e O-ring r O-ring t O-ring pressure indicator), stop operation, and replace
Port Applicable w Seal
Material order no. order no. order no. order no. the paper element or wash the micromesh ele-
size hydraulic fluid order no.
(Nominal size) (Nominal size) (Nominal size) (Nominal size) ment. If the micromesh element has reached the
KA00465 KA00463 KA00465 KA00470 end of its service life, replace it.
06 Petroleum, AL-206H
Water-glycol, NBR
(1A-G80) (1A-G65) (1A-G80) (1A-P28) • When replacing the element, check the O-rings
and replace them if they are damaged.
KA00453 KA00793 KA00453 KA00244
10 to 12 Emulsion
(1A-G105)
AL-207H
(1A-G85) (1A-G105) (1A-P42) • When washing the micromesh element, do not
wipe it using a stiff brush or rag.
KA00702 KA00614 KA00702 KA00717
06 FKM AL-206H-V
(4D-G80) (4D-G65) (4D-G80) (4D-P28)
Phosphoric ester or
KA00688 KA00703 KA00688 KA00723
10 to 12 EPDM AL-207H-V
(4D-G105) (4D-G85) (4D-G105) (4D-P42)
Note) The material of seals (AL-206H-V to AL-207H-V) is EPDM.

1535
Series FHBA

Dimensions
Differential Pressure Indication
Two indication methods are available: differential
pressure indicator and differential pressure indication
switch. These can be mounted on all filter models.
 Differential pressure indicator
4xM • Once
Operating pressure—0.18 MPa
• displayed
a value is displayed, it will continue to be
until reset, even if the pump is
øL stopped.
±3
• Perform element replacement when the red ring
floats up and covers the entire view port.

K
J

H

Reset button

4 x øP K View port
Mounting hole Mounting base dimensions

A A  Differential pressure indication switch


2 x Rc (d) • Operating pressure—0.18 MPa
• automatically
When a value has been displayed, it will be
reset when the pump is stopped.
Removal dimension G

(Non-reset type)
• This is a visual dual-purpose. Perform element
replacement when the switch has actuated
IN IN (when the red ring floats up and covers the entire
view port).
• N.C. and N.O. common
C
B
B

(F)
N

COM.
N.O.
N.C.
E

View port G1/2

øD

OUT

62 ∗ Refer to page 1549 for “Microswitch for differ-


Differential ential pressure indication switch”.
pressure Differential pressure
indicator indication switch
(65)
(34)
F

Differential pressure Differential pressure


indicator indication switch

(mm)
Port size Rc (d) A B C D E F G H J K L M N P
3/4 55 54 76 65 200 299 270 95 100 75 70 M8 12 10
1 1/4 210 342 320
75 76 112 89.1 120 128 100 95 M10 14 12
1 1/2 310 442 420

1536
Return Filter

Series FH100 RoHS

Specifications
Selection of elements for different Fluid Hydraulic fluid
applications Operating pressure Max. 1 MPa
Depending on the application, the user can Operating temperature Max. 80°C
choose among several standard element types,
Cover Cast iron
paper elements (5, 10 and 20 µm) and micro-
Case Aluminum casting
mesh elements (74 and 105 µm). Main material
O-ring NBR or FKM Note)
Easy maintenance Seal Stainless steel & NBR or Stainless steel & FKM Note)
The element slides into place and is sealed with
Material Paper Micromesh
an O-ring, making it easy to install and remove.
Element Nominal filtration 5, 10, 20 µm 74, 105 µm (200, 150 mesh)
Large drain exhaust outlet Differential pressure resistance 0.6 MPa
The large M16 drain exhaust outlet assures
Differential pressure indicator operating pressure 0.13 MPa
rapid drainage.
Relief valve open pressure 0.15 MPa
Clogging sensor Note) The material of the O-rings differs depending on the hydraulic fluid used.
The filter can be fitted with a differential pres- Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM
sure indicator (reset type) or differential pres-
sure indication switch (visual combined, non-
reset type). Model/Rated Flow Rate
Rated flow rate (L/min)
Model Port size (Rc)
Paper Micromesh
FH100-06 3/4 50 60
FH100-08 1 80 100
FH100-10 1 1/4 120 150
FH100-12 1 1/2 160 200
FH100-16 2 260 300
FH100-20 2 1/2 450 550
FH100-24 3 600 700

Accessory/Option
Description Part no. Note
CB-50H Petroleum, Water-glycol, Emulsion
Differential pressure indicator
CB-50H-V Phosphoric ester
FH
CB-51H Petroleum, Water-glycol, Emulsion
Differential pressure indication switch
(N.C. and N.O. common) CB-51H-V Phosphoric ester
HOW
Blanking cap AG-12H Petroleum
(for differential pressure indication AG-12H-W Water-glycol, Emulsion
part) AG-12H-V Phosphoric ester

1537
Series FH100

How to Order

FH 1 00 06 0 0 0 P 005
Hydraulic filter Made to Order
Nil None (Standard)
Operating pressure X0 Non-standard filtration
1 Max. 1 MPa Note) The non-standard filtration is
for micromesh elements only.
Refer to page 1548 for details.
Construction/Connection
00 Element downward removal, threaded Nominal filtration
005 5 µm
Port size (Rc) 010 10 µm
06 3/4 020 20 µm
Differential pressure indication 074 74 µm
08 1
10 1 1/4 0 None 105 105 µm
12 1 1/2 4 Differential pressure indicator Note) The paper elements for water-glycol or
16 2 5 Differential pressure indication switch Note) emulsion is 10 µm only.
Note) N.C. and N.O. common
20 2 1/2 Element
24 3
P Paper
Relief valve
M Micromesh
0 With relief valve
1 None Hydraulic fluid
0 Petroleum
1 Water-glycol, Emulsion
2 Phosphoric ester

Replacement Element Part No. (Including O-ring for element)


Paper Micromesh
Model 74 µm 105 µm Element size
5 µm 10 µm 20 µm
(200 mesh) (150 mesh)
FH100-06 EP420-005N EP420-010N EP420-020N EM810-074N EM810-105N
ø64 x 95
FH100-08 EP420-005N EP420-010N EP420-020N EM810-074N EM810-105N
FH100-10 EP020-005N EP020-010N EP020-020N EM910-074N EM910-105N
ø74 x 117
FH100-12 EP020-005N EP020-010N EP020-020N EM910-074N EM910-105N
FH100-16 EP520-005N EP520-010N EP520-020N EM020-074N EM020-105N ø88 x 158
FH100-20 EP620-005N EP620-010N EP620-020N EM120-074N EM120-105N
ø119 x 208
FH100-24 EP620-005N EP620-010N EP620-020N EM120-074N EM120-105N
Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type.
N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion (10 µm only for paper)
Note 2) Refer to page 1548 for non-standard filtration.
Note 3) Above elements require one element per filter.

Construction/Seal List
Replacement O-ring/Seal List (One each of the seal
and O-ring types listed below are required per filter.)
Blanking cap Differential pressure q O-ring w O-ring e Seal
Differential Port Applicable
indicator Material order no. order no. washer
pressure size hydraulic fluid
Relief valve Cover indication switch (Nominal size) (Nominal size) order no.
KA00800
06 to 08 KA00466
(1A-P35)
IN OUT
KA00082
10 to 12 Petroleum, (1A-G90)
(1A-P44)
q O-ring Water-glycol, NBR NB00006
KA00788 KA00806
Differential pressure 16 Emulsion
w O-ring indication switch (1A-G130) (1A-P50)
KA00756 KA00809
Element 20 to 24
(AS568-259,Hs70) (1A-P85)
KA00721
06 to 08 KA00704
(4D-P35)
KA00107
10 to 12 (4D-G90)
Phosphoric (4D-P44)
Case FKM NB00074
e Seal washer ester KA00690 KA00636
16
(4D-G130) (4D-P50)
Drain plug
KA00676 KA00725
DRAIN 20 to 24
(AS568-259,Hs70) (4D-P85)

1538
Return Filter Series FH100

Flow Characteristics
Differential Pressure Indication Handling Precautions
FH100-06 to 24: Nominal filtration 10 µm
Two indication methods are available: differen- q Mounting
0.1
12
tial pressure indicator and differential pressure
indication switch. These can be mounted on all
• Confirm IN and OUT before mounting. Then
connect so that the drain is oriented down-
filter models. ward. For maintenance, make sure to provide

24
0.05
16
10

 Differential pressure indicator sufficient space above the filter for removing
08

20
Pressure drop (MPa)

0.03
• Once
Operating pressure—0.13 MPa the element.
• be displayed
a value is displayed, it will continue to
until reset, even if the pump is
w Operation
• Operation of the differential pressure indicator
06

0.01 stopped. (Reset type)


• Perform element replacement when the red
ring floats up and covers the entire view port.
in cold weather, such as during winter, mostly
occurs due to high viscosity, so check wheth-
0.005 er it is from clogging or not after normal op-
eration starts.
Reset button
• Once the differential pressure indicator is ac-
tuated, the indication continues to be dis-
View port
played until the indicator is reset (by depress-
0.001 ing the reset button), even if the pump stops
10 30 50 100 300 500 operating.
Flow rate (L/min) Reset after replacing the element and restart-
ing operation, or after normal operation starts
Conditions Fluid: Turbine oil Class 2 VG56
Measured pressure: 1 MPa in cold weather such as during winter.
Viscosity: 45 mm2/s • When using a differential pressure indication
switch and if a filter clogged signal is incorpo-
Filter material: Paper
Nominal filtration: 10 µm rated into the sequence circuit of the ma-
 Differential pressure indication switch chine, make sure to design the system so the

FH100-06 to 24: Nominal filtration 74 µm • When


Operating pressure—0.13 MPa filter clogged signal does not operate until
• automatically
a value has been displayed, it will be
reset when the pump is
normal operation starts.
0.05 e Element replacement
stopped. (Non-reset type)
0.03 • This is a visual dual-purpose. Perform ele- • MPa
When the pressure difference reaches 0.13
during filter operation (actuating the dif-
12

ment replacement when the switch has actu- ferential pressure indicator), stop operation,
08

24

ated (when the red ring floats up and covers


10
Pressure drop (MPa)

drain the oil from the case, and replace the pa-
16

the entire view point). per element or wash the micromesh element.

20

N.C. and N.O. common


06

0.01 If the micromesh element has reached the end


of its service life, replace it.

0.005 COM.
• When replacing the element, check the O-
rings and replace them if they are damaged.

0.003
N.O.
N.C. • When washing the micromesh element, do
not wipe it using a stiff brush or rag.

View port G1/2

0.001
30 50 100 300 500
Flow rate (L/min) FH
Conditions Fluid: Turbine oil Class 2 VG56
Measured pressure: 1 MPa HOW
Viscosity: 45 mm2/s
Filter material: Micromesh
Nominal filtration: 74 µm

∗ Refer to page 1549 for “Microswitch for differ-


ential pressure indication switch”.

1539
Series FH100

Dimensions

Differential pressure
indication switch

Differential pressure 62
øF

indicator

Blanking cap

(65)
A 2 x Rc (d)

(34)
C

C
IN IN OUT IN OUT
OUT
E (Element removal dimension)

Differential pressure indicator Differential pressure indication switch


D

øB

DRAIN

(mm)
Model d A B C D E F Mass (kg)
FH100-06 3/4
102 90 35 200 290 2.5
FH100-08 1
104
FH100-10 1 1/4
110 100 45 265 380 4.3
FH100-12 1 1/2
FH100-16 2 150 128 52 299 430 144 6.8
FH100-20 2 1/2
200 157 70 387 540 175 17.5
FH100-24 3

1540
Oil Filter

Series FH150 RoHS

Specifications
Compact and lightweight Fluid Hydraulic fluid
The compact and lightweight design employs Operating pressure Max. 1 MPa
an aluminum alloy cover. Operating temperature Max. 80°C
Easy maintenance Cover Aluminum die-cast
The element slides into place, making it easy to Main material Case Steel plate
install and remove. O-ring NBR or FKM Note)
Clogging sensor Material Paper
The filter can be fitted with a differential pres- Element Nominal filtration 5, 10, 20 µm
sure indicator (reset type) or differential pres- Differential pressure resistance 0.6 MPa
sure indication switch (visual combined, non-
Differential pressure indicator operating pressure 0.13 MPa
reset type).
Note) The material of the O-rings and seals differs depending on the hydraulic fluid used.
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM

Model/Rated Flow Rate


Model Port size (Rc) Rated flow rate (L/min)
FH150-02 1/4 5
FH150-03 3/8 10
FH150-04 1/2 20

Accessory/Option
Description Part no. Note
CB-50H Petroleum, Water-glycol, Emulsion
Differential pressure indicator
CB-50H-V Phosphoric ester
Differential pressure indication switch CB-51H Petroleum, Water-glycol, Emulsion
(N.C. and N.O. common) CB-51H-V Phosphoric ester
Blanking cap AG-12H Petroleum
(for differential pressure indication AG-12H-W Water-glycol, Emulsion
part) AG-12H-V Phosphoric ester
Bracket B-44P —
FH
HOW

1541
Series FH150

How to Order

FH 1 50 02 0 1 0 P 005
Hydraulic filter Made to Order
Nil None (Standard)
Operating pressure X0 Micromesh element equipped
Note) Refer to page 1548 for details.
1 Max. 1 MPa

Construction/Connection Bracket
50 Element downward removal, threaded Nil None
B With bracket
Port size (Rc)
Nominal filtration
02 1/4
005 5 µm
03 3/8
010 10 µm
04 1/2
020 20 µm
Note) 10 µm only for water-glycol or emulsion.
Differential pressure indication
0 None Element
4 Differential pressure indicator P Paper
5 Differential pressure indication switch Note) M Micromesh
Note) N.C. and N.O. common
Hydraulic fluid
Relief valve 0 Petroleum
1 Water-glycol, Emulsion
1 None
2 Phosphoric ester

Replacement Element Part No. (Including O-ring for element)


Model 5 µm 10 µm 20 µm Element size
FH150-02
FH150-03 EP910-005N EP910-010N EP910-020N ø53 x 90
FH150-04
Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type.
N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion (10 µm only)
Note 2) Refer to page 1548 for micromesh elements.
Note 3) Above elements require one element per filter.

Construction/Seal List
Oil filter Differential
pressure
indication switch

Differential pressure
indicator
Blanking cap

IN OUT IN OUT IN OUT


Cover
Clamp ring

Case Differential pressure Differential pressure


q O-ring indicator indication switch
Element
w O-ring
Replacement O-ring/Seal List (One each of the seal
and O-ring types listed below are required per filter.)
q O-ring w O-ring
Port Applicable
Material order no. order no.
size hydraulic fluid
Spring (Nominal size) (Nominal size)
Petroleum, KA01022 KA00471
02 to 04 Water-glycol, NBR
Emulsion (1A-S65) (1A-P30)

KA01105 KA00104
02 to 04 Phosphoric ester FKM
(4D-S65) (4D-P30)

1542
Oil Filter Series FH150

Flow Characteristics
Differential Pressure Indication Handling Precautions
FH150-02 to 04
Two indication methods are available: differen- q Mounting
0.05
0.04
tial pressure indicator and differential pressure
indication switch. These can be mounted on all
• Confirm IN and OUT before mounting. Then
connect so that the case is oriented down-
0.03 filter models. ward. For maintenance, make sure to provide
 Differential pressure indicator sufficient space above the filter for removing
04

0.02
Pressure drop (MPa)

• Once
Operating pressure—0.13 MPa the element.
• be displayed
03

a value is displayed, it will continue to


0.01 w Operation
until reset, even if the pump is
• Operation of the differential pressure indicator
02

stopped. (Reset type)


0.005 • Perform element replacement when the red
ring floats up and covers the entire view port.
in cold weather, such as during winter, mostly
occurs due to high viscosity, so check wheth-
er it is from clogging or not after normal op-
Reset button eration starts.

View port
• Once the differential pressure indicator is ac-
tuated, the indication continues to be dis-
played until the indicator is reset (by depress-
0.001 ing the reset button), even if the pump stops
2 3 4 5 6 7 8 9 10 20 30 40 50 operating.
Flow rate (L/min) Reset after replacing the element and restart-
ing operation, or after normal operation starts
Conditions Fluid: Turbine oil Class 2 VG56
Measured pressure: 1 MPa in cold weather such as during winter.
Viscosity: 45 mm2/s • When using a differential pressure indication
switch and if a filter clogged signal is incorpo-
Filter material: Paper
Nominal filtration: 10 µm rated into the sequence circuit of the ma-
 Differential pressure indication switch
chine, make sure to design the system so the
• When
Operating pressure—0.13 MPa
filter clogged signal does not operate until
• automatically
a value has been displayed, it will be
reset when the pump is
normal operation starts.
stopped. (Non-reset type) e Element replacement
• ment
This is a visual dual-purpose. Perform ele-
replacement when the switch has actu-
• MPa
When the pressure difference reaches 0.13
during operation (actuating the differen-
ated (when the red ring floats up and covers tial pressure indicator), stop operation and re-
the entire view port). place the element.
• N.C. and N.O. common
• When replacing the element, drain the fluid
from the case. Also, check the O-rings and
replace them if they are damaged.
COM. r Other
N.O.
N.C. • Refer to the operating manual regarding the
tightening torque for clamping ring.
Use a commercially available hook wrench
View port G1/2 (applicable sizes 80 to 85 mm) for tightening
and removing clamping rings.

FH
HOW

∗ Refer to page 1549 for “Microswitch for differ-


ential pressure indication switch”.

1543
Series FH150

Dimensions

Differential pressure
62 indication switch

Differential pressure
ø16 indicator

(65)
A

(34)
F E 2 x Rc (d)
J
H

29

29
29
G

IN OUT IN OUT

Differential pressure indicator Differential pressure indication switch


D (Element removal dimension)

C
B

(mm)
Model d A B C D E F G H J Mass (kg)
FH150-02 1/4
FH150-03 3/8 80 168.5 197.5 259.5 50 15 25 7 6.5 0.7
FH150-04 1/2

1544
Magnetic Separator

Series FHM RoHS

Specifications
These magnetic separators protect FHMN: Petroleum, Water-glycol, Cutting oil, Emulsion
Fluid
machinery from malfunctions, reduced FHM: Petroleum, Water-glycol, Cutting oil, Emulsion, Phosphoric ester
precision, and burnout by adsorbing Operating temperature Max. 80°C
and eliminating contaminants in the Fluid speed 3 m/min or less
fluid by means of magnetism. This
helps extend the service life of Model
hydraulic equipment. Model Applicable fluid storage volume (L/unit) Note) Dimension (mm) Weight (kg)
FHMN-055 20 55 x t20 0.2
Zero running cost FHM-100 100 100 x t30 0.9
Since there are no consumable parts, the run- FHM-200 200 200 x 140 x t40 2.5
ning cost is basically zero and the magnetic Note) For example, three FHM100 magnetic separator units would be sufficient for a 300-liter fluid
separator can be used semi-permanently. storage tank.
Extends service life of hydraulic fluid
By adsorbing and eliminating contaminants, the Contaminant density of 200 ppm Separator after contaminant
magnetic separator retards deterioration of the adsorption
hydraulic fluid and makes it possible to extend
the fluid replacement time.
Reduced maintenance costs
The magnetic separator prevents mechanical
problems caused by contaminants such as
abrasive particles and greatly reduces mainte-
nance costs.

Fluid after cleaning with magnetic separator (5 ppm)

FH
HOW

Magnetic Separator Installation Examples


q U-turn flow type w Underflow type e Overflow type

Magnetic separator

Magnetic separator
Magnetic separator

1545
Series FHM

How to Order

Petroleum,
FHMN 055 FHM 100
Fluid

Water-glycol,
Cutting oil, Emulsion
Main unit representative Main unit representative
dimensions dimensions
Magnetic 055 55 x t20 100 100 x t30
separator Magnetic 200 200 x 140 x t40
separator

Fluid Iron Content Elimination Performance by Iron Particle Concentration


FHMN-055 Fluid: Hydraulic fluid FHM-100 Fluid: Hydraulic fluid FHM-200 Fluid: Hydraulic fluid

100 100 100 100


200
100 100
200
200 300 300
90 300 90 400 90 400
500
400 500
Elimination ratio (%)

Elimination ratio (%)

Elimination ratio (%)


80 500 80 80
75
70 70 70
60 60 60
50 50 50
40 40 40
30 30 30
20 20 20
10 10 10
0 0 0
1 5 10 50 100 1 5 10 30 50 100 1 5 10 50 100
Flow-back count Flow-back count Flow-back count

Explanation of graph Explanation of graph


Example: Elimination ratio and concentration after using the FHM-100 for one Calculate the flow-back count (N).
hour under the following conditions. Pump-out volume x Operation time 100 x 60
N= = = 30
Conditions 1. Volume of fluid in tank: 200 L Volume of fluid in tank 200
2. Pump-out volume: 100 L/min Based on the elimination ratio data for the FHM-100 and the point where
3. Contaminant concentration of used fluid: the 500 ppm line and flow-back count 30 line intersect (one hour after starting
500 ppm (initial concentration, percentage by volume) operation), the result is 75%.
4. Number of separators: 2 pcs. (applicable fluid storage volume of 100 L/unit)

Construction
FHMN-055 FHM-100

Magnet
Adsorption surface
Rubber case Cover Hexagon socket
Magnet Adsorption surface head cap screw

FHM-200 Base plate

Adsorption Hexagon socket


Cover
Magnet surface head cap screw

Base plate

1546
Magnetic Separator Series FHM

Dimensions
FHMN-055 FHM-100

55

100
20

115

FHM-200

32
15
Hexagon socket
head cap screw
(M6 x 10) 2 pcs.
140
70

215
42
20

Hexagon socket head cap screw FH


(M6 x 10) 4 pcs.

HOW
Handling Precautions
Mounting r If necessary, fix the separator in place. If frequent cleaning will be
q The flat portion of the stainless steel cover functions as the con- necessary, it can be suspended from the top panel of the tank.
taminant adsorption surface. However, for FHM-055, the flat por- t If a fluid switch (built-in lead switch) or the like is used, it should be
tion of the magnetic material functions as the contaminant adsorp- installed in a location where it will not be affected by magnetism
tion surface. from the separator. (Refer to the technical data sheet (SM-82-006)
w Mount the magnetic separator in a location where fluid is constant- for information on magnetic fields.)
ly flowing by in laminar flow. Maintenance
e Avoid locations such as near the suction pipe or return pipe, q Clean the separator regularly. Make sure to clean it once the accu-
places where there is turbulence, and locations where the flow mulation of contaminants reaches a thickness of 20 mm or so.
speed is 3 m/min or greater.
w Clean the adsorption surface of the separator by wiping away the
accumulated contaminants using a soft rag or the like.
Handle-equipped type Cover/handle-equipped type
Handling
q Do not bring the top surface of the separator near magnetically at-
tractive objects such as iron plates.
w Handle the separators individually and do not bring them into close
proximity with each other.
Tank-fixed type e Be careful not to get your fingers caught between iron plates, etc.,
when installing the separator.
r Do not bring objects that are affected by magnetism (cards with
magnetic strips, watches, etc.) near the separator.

1547
Series FH
Made to Order Specifications:
Please consult with SMC for detailed specifications, delivery and prices.

Symbol
1 Non-Standard Filtration X0

Filter symbol (Refer to “How to Order” for each series) X0


Note) Made-to-order specifications (non-standard filtration rating) are available only for micromesh
elements (element symbol: M). Made to Order
(Non-standard filtration or
Micromesh element equipped)

Hydraulic Filter Non-Standard Filtration Replacement Element Part No.

Replacement element part no.

Description Model Port size Micromesh element Element size


Micromesh element
(With relief valve)

1/2 EM001H-∗1∗2 — ø65 x L90


3/4, 1 EM101H-∗1∗2 — ø85 x L110
FHIA 1 1/4, 1 1/2 EM201H-∗1∗2 — ø100 x L160
Vertical suction filter
(Refer to P. 1519.) 2 EM301H-∗1∗2 — ø120 x L180
2 1/2, 3 EM401H-∗1∗2 — ø140 x L200
3 1/2, 4 EM501H-∗1∗2 — ø180 x L260
1/2, 3/4 EM230-∗1∗2 EM520-∗1∗2 ø65 x L90
1,1 1/4 EM330-∗1∗2 EM620-∗1∗2 ø82 x L133
1 1/2 EM430-∗1∗2 EM720-∗1∗2 ø104 x L177
Suction filter with case FH99 2 EM530-∗1∗2 EM820-∗1∗2 ø104 x L177
(Refer to P. 1523.)
2 1/2 EM630-∗1∗2 EM920-∗1∗2 ø132 x L212
3 EM730-∗1∗2 EM030-∗1∗2 ø132 x L212
3 1/2, 4 EM830-∗1∗2 EM130-∗1∗2 ø155 x L193
1/2, 3/4, 1 EM220-∗1∗2 — ø69 x L88
Suction guard
FHG 1 1/4, 1 1/2, 2 EM320-∗1∗2 — ø89 x L123
(Refer to P. 1527.)
2 1/2, 3 EM420-∗1∗2 — ø109 x L188
3/8, 1/2 EM040-∗1∗2 — ø53.1 x L90
FH34
FH44 3/4, 1 EM910-∗1∗2 — ø73.5 x L117
Line filter FH54 1 1/4, 1 1/2 EM140-∗1∗2 — ø73.5 x L195
FH64 2 EM930-∗1∗2 — ø87.6 x L282
(Refer to P. 1531.)
2 1/2, 3 EM240-∗1∗2 — ø118.7 x L280
3/4 EM601H-∗1∗2 — ø56 x L180
Vertical return filter
FHBA 1 1/4 EM701H-∗1∗2 — ø76 x L190
(Refer to P. 1535.)
1 1/2 EM801H-∗1∗2 — ø76 x L290
3/4, 1 EM810-∗1∗2 — ø65 x L95
FH100 1 1/4, 1 1/2 EM910-∗1∗2 — ø73.5 x L117
Return filter
(Refer to P. 1538.) 2 EM020-∗1∗2 — ø87.6 x L157
2 1/2, 3 EM120-∗1∗2 — ø118.7 x L207

Oil filter
FH150 1/4, 3/8, 1/2 EM040-∗1∗2 — ø53 x L90
(Refer to P. 1542.)

Note) In the table above ∗1 indicates nominal filtration and ∗2 indicates hydraulic fluid type.

Nominal Filtration Hydraulic Fluid


Symbol (∗1) µm Symbol (∗2) Type
003 3
N Petroleum
005 5
010 10
W Water-glycol, Emulsion
020 20
040 40
V Phosphoric ester
074 74
105 105
149 149
270 270

1548
Series FH
Microswitch for Differential Pressure Indication Switch
(1) Contact specifications (4) Electric circuit
Table 1 Contact specifications NC
Item Specifications
Inrush current Max. 15 A NO
Minimum applicable load 5 VDC 160 mA
COM

(N.C. and N.O. common)


(2) Rating
Precautions
1. Connect desired wiring to the micro switch indication symbols 1 (COM.), 2
Table 2 Rating (N.C.), and 3 (N.O.).
Rated voltage Resistance load 2. When a protection mechanism is required, take appropriate considerations
on the electric circuit since the micro switch is a type of non-reset.
250 VAC 5A

(3) Other performance (5) Terminal type


Table 3 Other specifications Soldering terminal
Item Specifications
Insulation resistance 100 MΩ or more (Measured by 500 VDC, insulation resistance tester.)
Contact resistance 30 mΩ or less
Between terminals with the same pole. 1,000 VAC 50/60 Hz 1 min
Between charged metal
Withstand 1,500 VAC 50/60 Hz 1 min
part and ground
voltage
Between each terminal and
1,500 VAC 50/60 Hz 1 min
non-charged metal part

FH
HOW

1549
FH
Series
Specific Product Precautions
Be sure to read this before handling.
Refer to front matter 38 for Safety Instructions.

Design Piping

Caution Caution
1. Do not use at a pressure that exceeds the operating 1. Make sure to allow sufficient space for maintenance
pressure range. when installing and piping.
2. Do not use at a temperature that exceeds the oper- 2. Connections
ating temperature range. Make sure no cutting chips from pipe threads or sealing mate-
3. Fluid rial gets inside the piping. If sealing tape is used, leave 1.5 to
2 thread ridges exposed at the end of the male thread.
Do not use the product with gases. Do not use fluid other than
hydraulic fluid. 3. Filter installation
Use stays or the like to secure the inlet and outlet pipes so
4. Fatigue damage
that the filter unit is not subjected to external force such as vi-
Under the following conditions, special measures are required: bration.
1. If the product will be subjected to pressure surges.
2. If the product is not mounted securely and will be subject to
friction or vibrations.
Operating Environment
5. Corrosion
The product may corrode depending on usage conditions and
environment.
Caution
1. If the product is used in an environment or location
conducive to corrosion, discoloration or deteriora-
Selection tion due to corrosion may occur.
2. Fatigue damage may occur if the product is used in
Warning a location subject to vibrations or impacts.
1. When selecting products, carefully consider the us-
age purpose, the required specifications, and the
usage conditions (fluid, pressure, flow rate, tem- Maintenance
perature, environment), and ensure that the specifi-
cation range is not exceeded. Caution
2. The fluid used must not be heated to the boiling 1. The differential pressure will increase if the filter be-
point. comes clogged with foreign matter.
3. Do not use the product with air or other gases un- The differential pressure indicator operation pressure is the
pressure difference at which the element should be replaced.
der any circumstances.
When the pressure difference rises to this level, replace the
4. Do not use the product in circumstances where it element with a new one. A differential pressure indicator and
will be exposed to pressure that exceeds the rated differential pressure indication switch are available as options.
operating pressure range, such as with a water
hammer or surge pressure.

Fluid

Warning
1. Do not use fluid other than hydraulic fluid.

1550