Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Design of Cables

Main Structural Cables

Maximum Tensile Loads on Main Cable = 464.4 kN


(Results obtained from Spacegass Analysis)
Galfan Coated Steel-Open Spiral Strands

Diameter of Cable used= 24.4 mm


Minimum Breaking Load= 537 kN Safe

Galfan Coated Steel- Full Locked Strands

Diameter of Cable used= 26 mm


Minimum Breaking Load= 621 kN Safe

Main Structural Cables

Maximum Tensile Loads on Main Cable = 10.3 kN


(Results obtained from Spacegass Analysis)
Galfan Coated Steel-Open Spiral Strands

Diameter of Cable used= 12.2 mm


Minimum Breaking Load= 134 kN Safe

Galfan Coated Steel- Full Locked Strands

Diameter of Cable used= 21 mm


Minimum Breaking Load= 405 kN Safe
Galfan Coated Steel-Open Spiral Strands

Nominal Cable Diameter Minimum Breaking Load


8.1 59
10.1 93
12.2 134
14.1 181
17 260
20.1 367
24.4 537
28.3 722
31.3 884
36.3 1189

Galfan Coated Steel- Full Locked Strands

Nominal Cable Diameter Minimum Breaking Load


21 405
26 621
31 916
35 1170
40 1520
45 1930
50 2380
55 3020
60 3590
65 4220
70 4890
75 5620
80 6390
85 7210
90 8090
95 9110
100 10100
105 11100
110 12200
115 13400
120 14500
125 15800
130 17300
135 18600
140 20000

You might also like